Search Results

Search found 22961 results on 919 pages for 'memory management'.

Page 854/919 | < Previous Page | 850 851 852 853 854 855 856 857 858 859 860 861  | Next Page >

  • ubuntu eth0 not reconnecting after cable unplugged

    - by Alex
    I'm running kubuntu 9.10 w/ gnome, I have a static IP defined in /etc/network/interfaces When I unplugged my network cable and rebooted, then reconnected the network cable I was not able to connect. I tried using sudo ifup eth0, and then ifconfig and it seemed as though the IP address had been assigned and I was connected, but I wasn't. I then did ifdown eth0, and again ifup eth0. For some reason I'm not able to access the network. Furthermore, I also attempted to connect via wlan, and was able to connect to the wireless network, but cannot "see" the network. I can't transfer data or access the internet or anything on the network including the router. How do I resolve this? topsy@monolyth:~$ ifconfig eth0 Link encap:Ethernet HWaddr 00:1c:25:1c:df:70 inet addr:192.168.1.145 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::21c:25ff:fe1c:df70/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:5720 errors:0 dropped:0 overruns:0 frame:0 TX packets:565 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:378035 (378.0 KB) TX bytes:46832 (46.8 KB) Memory:fe000000-fe020000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:4 errors:0 dropped:0 overruns:0 frame:0 TX packets:4 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:240 (240.0 B) TX bytes:240 (240.0 B) By access the network I mean the local network as well as the internet. topsy@monolyth:~$ ping 192.168.1.1 PING 192.168.1.1 (192.168.1.1) 56(84) bytes of data. 64 bytes from 192.168.1.1: icmp_seq=1 ttl=64 time=9.14 ms 64 bytes from 192.168.1.1: icmp_seq=2 ttl=64 time=1.24 ms 64 bytes from 192.168.1.1: icmp_seq=3 ttl=64 time=1.01 ms 64 bytes from 192.168.1.1: icmp_seq=4 ttl=64 time=1.00 ms [snip... all OK, icmp_seq from 5-30, time between 0.981-1.25ms] ^C --- 192.168.1.1 ping statistics --- 30 packets transmitted, 30 received, 0% packet loss, time 29035ms rtt min/avg/max/mdev = 0.971/1.300/9.140/1.458 ms topsy@monolyth:~$ route Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 192.168.1.0 * 255.255.255.0 U 0 0 0 eth0 link-local * 255.255.0.0 U 1000 0 0 eth0 default 192.168.1.1 0.0.0.0 UG 100 0 0 eth0 root@monolyth:~# cat /etc/resolv.conf # Generated by NetworkManager

    Read the article

  • Providing DNS redirection to honeypot server for known bad domains

    - by syn-
    Currently running BIND on RHEL 5.4 and am looking for a more efficient manner of providing DNS redirection to a honeypot server for a large (30,000+) list of forbidden domains. Our current solution for this requirement is to include a file containing a zone master declaration for each blocked domain in named.conf. Subsequently, each of these zone declarations point to the same zone file, which resolves all hosts in that domain to our honeypot servers. ...basically this allows us to capture any "phone home" attempts by malware that may infiltrate the internal systems. The problem with this configuration is the large amount of time taken to load all 30,000+ domains as well as management of the domain list configuration file itself... if any errors creep into this file, the BIND server will fail to start, thereby making automation of the process a little frightening. So I'm looking for something more efficient and potentially less error prone. named.conf entry: include "blackholes.conf"; blackholes.conf entry example: zone "bad-domain.com" IN { type master; file "/var/named/blackhole.zone"; allow-query { any; }; notify no; }; blackhole.zone entries: $INCLUDE std.soa @ NS ns1.ourdomain.com. @ NS ns2.ourdomain.com. @ NS ns3.ourdomain.com.                        IN            A                192.168.0.99 *                      IN            A                192.168.0.99

    Read the article

  • Are FC and SAS DAS devices standard enough?

    - by user222182
    Before I ask my questions, here is some background info that may or may not be useful: For the first time I find myself needing a DAS solution. My priority is data through-put in a single direction. I can write large blocks, and I don't need to read at the same time. The server (the data producing device) is not really a typical server, its a very powerful single board computer. As such I have limited options when it comes to the add-in cards I can install since it must use the fairly uncommon interface, XMC. Currently I believe I am limited PCIex8 gen 1 which means that the likely bottle neck for me will be this 16gbps connection. XMC Boards I have found so far offer the following connections: a) Dual 10GBE ethernet controller, total throughput 20gbps b) Dual Quad SAS 2.0 Connectors (SFF-8XXX) HBA (no raid), total throughput 48 gbps c) Dual FC 8gb HBA (no raid), total throughput 16gbps My questions for you guys are: 1) Are SAS and/or FC, and by extension their HBAs, standard enough that I could purchase a Dell or Aberdeen storage server with a raid controller that has external SAS or FC ports and expect that I can connect it to my SAS or FC HBA, be presented with a single volume (if I so configured the storage server), all without having to check for HBA compatibility? 2) On a device like a Dell PowerVault (either DAS or NAS) is there an OS on it to concern myself with, or is it meant to be remotely managed? Is there a local interface in case I cant remotely manage it (i.e. if my single board computer uses an OS not supported by Dell OpenManage). Would this be true of nearly any device which calls itself a DAS? 3) If I purchase some sort of Supermicro storage chassis, installed a raid controller with external connections, is there a nice lightweight OS I can run just for management of the controller? Would I even need an OS since the raid card would be configured pre-boot anyway? 4) It is much easier to buy XMC based 10gigabit ethernet cards (generally dual port). In what ways would I be getting into trouble by using iSCSI as a DAS are direct cabling with SFP+ cables? Thanks in advance

    Read the article

  • How to get php mail function to work on Debian “squeeze”?

    - by Neel Kamal
    I have installed Apache and PHP5 on my debian server. Firstly I tried it using sendmail. Here is the step by step procedure that I have tried : Step 1: apt-get install sendmail Step 2: /etc/init.d/apache2 restart But this didn't work. Then I tried using external SMTP . My domain is registered on BigRock.I registerd an email address there [email protected] and it gave me the required credentials. On server I installed sSMTP > apt-get install ssmtp > Configured "/etc/ssmtp/ssmtp.conf" file. In the configuration file I added [email protected] mailhub=smtp.fostergen.com:587 (Here I have doubt. I am not sure what to use here. I tried smtp.fostergen.com:587, smtp.fostergen.com:25,mx1.mailhostbox.com :587,mx1.mailhostbox.com:25. I am still not sure what to use here mailhostbox.com. I used mx1.mailhostbox.com as it was the mx entry for my domain on bigrock Here is the screenshot![screenshot of bigrock's email management tool] ) hostname=vs3204.ams2.alvotec.de (I entered the command hostname -f on my server and got it as result ) FromLineOverride=YES UseSTARTTLS=YES [email protected] AuthPass=password provided during email registration on bigrock > edited /etc/ssmtp/revaliases (added " root:[email protected]:mx1.mailhostbox.com :587 " in the last line) > edited php.ini file (sendmail_path = /usr/sbin/ssmtp -t) > /etc/init.d/apache2 restart But this didn't work. After this I tried eSMTP. Steps Performed : > apt-get install esmtp > edited /etc/esmtprc hostname=smtp.fostergen.com:587 username= [email protected] password: password provide by bigrock mda="/usr/bin/procmail -d %T" > linked eSMTP to the legacy Sendmail path by execting the command "ln -s /usr/bin/esmtp /usr/bin/sendmail" > edited php.ini file (/usr/bin/sendmail -t -i) > /etc/init.d/apache2 restart But this technique also failed. I just want to send email to users through php mail function. Kindly help. Where I am going wrong?

    Read the article

  • Resizing Partitions on Live RHEL/cPanel Server

    - by Timothy R. Butler
    I've resized many partitions over the years on Linux, Windows and Mac OS X -- but always using a GUI. However, the time has come where the preset partition sizes my data center placed on my server aren't the right sizes and I need to resize a production server's disks. I could fiddle with it and probably do OK, but given that it is a production server, I wanted to get some advice about the right way to do this. I do have KVM over IP access, so if it is best to take the server offline and boot off a rescue partition, I can do that. root [/var/lib/mysql]# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda2 9.9G 2.1G 7.3G 23% / tmpfs 7.8G 0 7.8G 0% /dev/shm /dev/sda1 99M 77M 18M 82% /boot /dev/sda8 884G 463G 376G 56% /home /dev/sda3 9.9G 8.0G 1.5G 85% /usr /dev/sda5 9.9G 9.1G 308M 97% /var /usr/tmpDSK 2.0G 38M 1.8G 3% /tmp As you can see /var and /usr are quite close to being full and I've actually had to symlink some logs on /usr to directories in /home to balance things out. What I would like to do is to add 6-10 GB each to /usr and /var, presumably taking the space from /home. As I think about how the disk is arranged, the best thought I've come up with is to reduce /home by 16 GB, say, and move /var to the spot freed up, then allocating /var's space to /usr. However, that would put /var at the far end of the disk, which seems less than idea, given that MySQL has all of its data on that partition. I'd love to take the space out of the closer end of /usr, but I assume that would take a very arduous (and perhaps risky) process of moving all of the data in /usr around. I seem to recall having such a process fail for me on a computer in the past. The other option might be to merge / and /usr since / is underutilized, though I'm not sure if that's a good idea. Do you have any suggestions both on the best reallocation plan and the commands to use to accomplish it? UPDATE: I should add -- here's the partition table. There's one unused partition, which, if memory serves, was the original tmp location before I created a tmp image: Name Flags Part Type FS Type [Label] Size (MB) ------------------------------------------------------------------------------ Unusable 1.05* sda1 Boot Primary Linux ext2 106.96* sda2 Primary Linux ext3 10737.42* sda3 Primary Linux ext3 10737.42* sda5 NC Logical Linux ext3 10738.47* sda6 NC Logical Linux swap / Solaris 2148.54* sda7 NC Logical Linux ext3 1074.80* sda8 NC Logical Linux ext3 964098.53*

    Read the article

  • Small Business Server services will not start, and remote desktop and UAC are broken

    - by Stephen Jennings
    Yesterday I began setting up a server with Windows Small Business Server 2008. All I am configuring it for right now is to be a domain controller and Exchange server. I completed the initial setup of SBS then started looking through different connection options (allowing VPN versus using a TS Gateway). After I rebooted one time, I started having three not-obviously-related issues: First, I could no longer remote desktop into the computer. I ran TCPView and saw that it was no longer listening on port 3389. I checked everything in Terminal Service Configuration but everything shows the computer ought to be allowing connections. Also, when I tried to use anything that required user account control elevation, the UAC dialog never popped up and the program that was waiting just froze. If I try to run "regedit" from the Run box, for example, it never appears. When I run in safe mode which does not run with UAC, I was able to access everything. I didn't want to deal with it, so I turned off UAC and rebooted. Finally, in the Windows SBS Console, there are status indicators for Security, Updates, Backup, and Other Alerts. The first three get stuck saying "Querying". Looking in the computer alerts, I have events showing the following services stopped: Background Intelligent Transfer Service KtmRm for Distributed Transaction Coordinator Distributed Transaction Coordinator Microsoft Exchange Information Store Microsoft Exchange System Attendant Microsoft Exchange Transport Windows Remote Management Update Services Windows Update I figured I must have configured something wrong accidentally and I couldn't find anything using Google explaining what might be the case, so I just decided to format the hard drive and reinstall SBS from scratch. I did this and everything was working last night, but I just turned the machine back on and it is doing the same thing again! On my second install, I did not configure anything except the following (all from SBS Console): Connect to the Internet (set IP and router address) Turn off customer feedback. Set up internet address. Decline to use a Smart Host for email. Added one standard user account. Since this happened again and I was very careful the second time not to configure anything outside of the SBS Console, I feel like there's something else going on. Right now the machine is on an isolated network that does have internet access. My desktop is the only other machine plugged into this network. Any and all help is appreciated (before I tear my hair out!)

    Read the article

  • RHEL 6.x on Rackspace Cloud and Dedicated hardware experiencing Redis Timeouts

    - by zhallett
    I just recently set up a mixture of RHEL 6.1 Rackspace cloud hosts and RHEL 6.2 dedicated hosts using Rackconnect. I am experiencing intermittent Redis timeouts from within our Rails 3.2.8 app with Redis 2.4.16 running on the RHEL 6.2 dedicated hosts. There is no network latency or packet loss. Also there are no errors on any interfaces on our cloud or dedicated servers or on the managed firewall from Rackspace. When Redis timesout, there is nothing logged within redis even though it is set up to do debug logging. The only error we receive is from Airbrake saying there was a Redis timeout. Network topology: RHEL 6.1 cloud hosts <--> Alert logic IDS <--> Cisco ASA 5510 <--> RHEL 6.2 dedicated hosts (web nodes) (two way NAT) (db hosts running redis) Ping from db host to web host: 64 bytes from 10.181.230.180: icmp_seq=998 ttl=64 time=0.520 ms 64 bytes from 10.181.230.180: icmp_seq=999 ttl=64 time=0.579 ms 64 bytes from 10.181.230.180: icmp_seq=1000 ttl=64 time=0.482 ms --- web1.xxxxxx.com ping statistics --- 1000 packets transmitted, 1000 received, 0% packet loss, time 999007ms rtt min/avg/max/mdev = 0.359/0.535/5.684/0.200 ms Ping from web host to db host: 64 bytes from 192.168.100.26: icmp_seq=998 ttl=64 time=0.544 ms 64 bytes from 192.168.100.26: icmp_seq=999 ttl=64 time=0.452 ms 64 bytes from 192.168.100.26: icmp_seq=1000 ttl=64 time=0.529 ms --- data1.xxxxxx.com ping statistics --- 1000 packets transmitted, 1000 received, 0% packet loss, time 999017ms rtt min/avg/max/mdev = 0.358/0.499/6.120/0.201 ms Redis config: daemonize yes pidfile /var/run/redis/6379/redis_6379.pid port 6379 timeout 0 loglevel debug logfile /var/lib/redis/log syslog-enabled yes syslog-ident redis-6379 syslog-facility local0 databases 16 save 900 1 save 300 10 save 60 10000 rdbcompression yes dbfilename dump-6379.rdb dir /var/lib/redis maxclients 10000 maxmemory-policy volatile-lru maxmemory-samples 3 appendfilename appendonly-6379.aof appendfsync everysec no-appendfsync-on-rewrite no auto-aof-rewrite-percentage 100 auto-aof-rewrite-min-size 64mb slowlog-log-slower-than 10000 slowlog-max-len 1024 vm-enabled no vm-swap-file /tmp/redis.swap vm-max-memory 0 vm-page-size 32 vm-pages 134217728 vm-max-threads 4 hash-max-zipmap-entries 512 hash-max-zipmap-value 64 list-max-ziplist-entries 512 list-max-ziplist-value 64 set-max-intset-entries 512 zset-max-ziplist-entries 128 zset-max-ziplist-value 64 activerehashing yes Redis-cli info: redis-cli info redis_version:2.4.16 redis_git_sha1:00000000 redis_git_dirty:0 arch_bits:64 multiplexing_api:epoll gcc_version:4.4.6 process_id:4174 uptime_in_seconds:79346 uptime_in_days:0 lru_clock:1064644 used_cpu_sys:13.08 used_cpu_user:19.81 used_cpu_sys_children:1.56 used_cpu_user_children:7.69 connected_clients:167 connected_slaves:0 client_longest_output_list:0 client_biggest_input_buf:0 blocked_clients:6 used_memory:15060312 used_memory_human:14.36M used_memory_rss:22061056 used_memory_peak:15265928 used_memory_peak_human:14.56M mem_fragmentation_ratio:1.46 mem_allocator:jemalloc-3.0.0 loading:0 aof_enabled:0 changes_since_last_save:166 bgsave_in_progress:0 last_save_time:1352823542 bgrewriteaof_in_progress:0 total_connections_received:286 total_commands_processed:507254 expired_keys:0 evicted_keys:0 keyspace_hits:1509 keyspace_misses:65167 pubsub_channels:0 pubsub_patterns:0 latest_fork_usec:690 vm_enabled:0 role:master db0:keys=6,expires=0 edit 1: add redis-cli info output

    Read the article

  • Crashes and freezes after fixing "BOOTMGR is missing" error

    - by Greg-J
    I came back from a 3-day weekend to a computer that was off. I leave my PC on 24/7, so this was odd. Turn it on to get the dreaded "BOOTMGR is missing" screen. Two attempts at Windows Recovery and it booted into Windows fine. After an hour or so, I get a frozen Chrome and my start bar disappears. Ctrl+Alt+Del brings up an error box telling me that Ctrl+Alt+Del failed to work properly. Clicking on any open application triggers an error (I can't recall the error now, but it essentially just said that the application couldn't be found running or something along those lines). I restart, and again, the same thing happens after a while of use. I turn it on, install the 47 updates I have or so, and then restart it. After a while of use (under an hour), it just freezes completely. My thoughts are: SSDs, RAM or PS. My system specs below: (RAID0) 2 x Crucial M4 CT128M4SSD2 2.5" 128GB SATA III MLC Internal Solid State Drive (SSD) CORSAIR Vengeance 16GB (4 x 4GB) 240-Pin DDR3 SDRAM DDR3 1600 (PC3 12800) Desktop Memory Model CML16GX3M4A1600C9 CORSAIR HX Series HX750 750W ATX12V 2.3 / EPS12V 2.91 SLI Ready CrossFire Ready 80 PLUS GOLD Certified Modular Active 1 x ASUS Maximus IV Gene-Z/GEN3 LGA 1155 Intel Z68 HDMI SATA 6Gb/s USB 3.0 Micro ATX Intel Motherboard 1 x Hitachi GST Deskstar 7K1000.C 0F10383 1TB 7200 RPM SATA 3.0Gb/s 3.5" Internal Hard Drive -Bare Drive 1 x Intel Core i7-2600K Sandy Bridge 3.4GHz (3.8GHz Turbo Boost) LGA 1155 95W Quad-Core Desktop Processor Intel HD Graphics 1 x SAPPHIRE 21197-00-40G Radeon HD 7970 3GB 384-bit GDDR5 PCI Express 3.0 x16 HDCP Ready CrossFireX Support Video Card 1 x Noctua NH-D14 120mm & 140mm SSO CPU Cooler This is all crammed in a pretty small case (NZXT Vulcan) and has been running perfectly problem-free since January. The only thing out of the ordinary is that there is a fan in the case that is now making noise whereas the case has previously been completely silent. I have no reason to believe this is anything more then correlation, but felt it is worth mentioning. I believe it MAY be the SSDs simply because of the BOOTMGR error, but not sure how to test that theory. My belief that it may be the RAM is simply from experience with frozen machines. I haven't had the time to memtest it, but will. The PS being the culprit is something I've picked up by reading similar threads on various forums, and it seems plausible. I am unsure how to test this though. ANY insight whatsover would be greatly appreciated!

    Read the article

  • usb mouse connecting and disconnecting randomly and often

    - by Kalec
    Yes, I know this question has been asked here before but I can't add to the discussion over there and it did not help me, so here goes nothing. I've bought an acer aspire 5742G about 2 months ago or so and it's been running great, but sometimes I used to hear the windows error beep but I had no idea what was causing it since the "bug" was automatically fixed so fast I couldn't even see an error message (also it kinda always happened when I was busy also, either in a game or while doing my homework). Later on my mouse would simply not work for 3-5 seconds then work again, I thought nothing of it at the time. I also had a problem where it only worked in one usb and one only ... to move it I had to remove the battery, unplug the laptop and hold the power button for 2 minutes to reset the bios settings. Since today though it went nuts ... sometimes it disconnects / reconnects 12 times in 10 seconds and windows just keeps beeping till I unplug it, then it runs smooth for 5-6 minutes then it goes nuts again. Other times it seems like it skips (disconnects for a fraction of a second) other times just for 2-3 seconds. But this is incredibly frustrating. Sometimes the power just goes down (the laser turns off) and well that at least I would understand but this is a rare occurance. Now I know the usb ports work since I have a lot of other devices connected and I tried the mouse on a room m8's laptop so the mouse also works. My only conclusion is that it's an operating system / settings bug and / or problem (I have tried the mouse in all ports by the way). All drivers and bios are up to date (maybe except mouse but i can't seem to update that and the mouse has no name, just a serial number which helps with nothing. Still it worked till today and nothing should have changed any way). I have made sure windows can't shut it down to save power (in device management). Also I tried to delete the drivers and re-install them, rebooting and the power button trick but nothing ... most I have done is get rid of the 12 discconnects / reconnects every 10 seconds :) but that's all :( I would buy a new one but I'm afraid it might do the same thing :| ****EDIT****** Tried the mouse again at a friend but now it didn't even install it's software nor did the update work ... think I'll just buy a new one but I'd still like a suggestion at least so I'll leave this open

    Read the article

  • CPU Lockup when loading folder of bookmarks in Firefox

    - by Gary M. Mugford
    I am running Firefox 3.6 on WinXPSP3 on a duo Core machine with 4G of memory. I am also running Avast! free anti-virus and ZoneAlarm free firewall, both latest versions. Within the last month, my service provider basically forced me to upgrade to a Docsis 3.0 compliant modem (offered me a deal I couldn't turn down). At that point, I also upgraded to FF3.6. Basically, I am not unhappy with many aspects of this switchover, EXCEPT, when I now load a folder of bookmarks (anywhere from 10 to 38) I get nothing like the load times I experienced a couple of months back. It's taking minutes rather than seconds. And the first bookmark in one of the folders, GMail, rarely loads before timing out. I have used the old trick of powering off the cable modem before my day's work. This used to fix 'load-lag' in the old days. I have switched from my ISP's DNS server to Google, OpenDNS and back. And nothing seems to work currently. It's not my DNS cache. That's been flushed and secondary computers also have the same issue when loading folders. I have watched the CPU usage and loading the folder will send VSMon (ZoneAlarm) usage over 40 percent, AVastSvc (Avast!) over 30 and Firefox will then push the needle to 100. There's a brief burst by SVCHost when the others falter in devouring cycles. Then everything subsides to single digits once the last tab is loaded. The only other nominal nastiness is VSMon ALWAYS hitting 50 percent when ANY program starts downloading content from the internet. If I shutdown ZoneAlarm (and VSMon with it), the same slow loading takes place, but this time System is running 50% plus, again driving the usage to 100 per cent. I have my doubts FF3.6 vs FF3.5 is an issue, since the other computers are still running 3.5 and suffer the same issue. Those computers are on, but inactive, most of the time, being backups. Obviously, when the CPU hits 100, I can't do much of anything in FireFox OR in other programs. Video play through WMPC or VLC is extremely choppy, although it doesn't seem to affect the audio. Any ideas what I can try next? Thanks, GM

    Read the article

  • How do I get the latest FastCGI and PHP versions to peacefully coexist on IIS 6?

    - by BHelman
    I have been going round and round trying to get any sort of PHP running on IIS 6. I somehow managed to successfully get version 5.1.4 running using the php5isapi.dll file. However, I want to upgrade a website to begin using a Content Management System. I have never dug into CMS before so I'm open to programs that are easy to use. I am currently looking into TomatoCMS and ImpressCMS - but that's beside the point. I have never done an installation with PHP before and I think I'm getting familiar with how it works. However the current situation is this. Microsoft's Web Platform Installer 2.0 installed FastCGI for me. I need to upgrade to PHP 5.3.1 for a CMS system. So I downloaded the Windows installer and let it go at it. After consulting several other blog articles, I believe I know how it is supposed to work but I am currently not having luck. THE SETUP *.php is a registered extension in IIS 6 for all websites (on Win 2k3). The application that it calls is C:\Windows\system32\inetsvr\fcgiext.dll, like it should. The fcgiext.ini config has the proper lines: [Types] php=PHP [PHP] ext=C:\program files\PHP\php-cgi.exe And the php.ini file also has the correct configs. All extensions are disabled and I changed the correct things for FastCGI. And everything is registered correctly with the PATH variable. Everything is exactly how it should be. BUT when I launch the "info.php" page () on another computer, I get the following error: FastCGI Error The FastCGI Handler was unable to process the request. Error Details: * Section [PHP] not found in config file. * Error Number: 1413 (0x80070585). * Error Description: Invalid index. HTTP Error 500 - Server Error. Internet Information Services (IIS) A quick Google search reveals that I have it all setup correctly as far as the INI's go and the mapping of the php extension. I am completely at a loss. Does anyone have any suggestions? Although the server is hosting three small websites, I don't really care what I have to do to it to get it to work.

    Read the article

  • Windows XP installation problems

    - by Samurai Waffle
    I recently asked a question on here, and thought I had it working... Here is a link to it. Windows XP Installation problems So basically I'm having trouble getting XP installed. To sum it up, a computer I have had a boot sector virus, and I used Darik's Nuke and Boot to wipe the hard drive clean. So the hard drive has nothing on it. I had to try and install Windows through a DOS prompt, because for some reason it won't read it off the DVD. The UBCD is able to look at the files located on the DVD I have in, but I can't boot from it for some reason. So I extracted it to a USB drive, booted to DOS and started the setup process. Here's the weird thing with DOS... It can only find the C: drive. The C: drive in DOS is the flash drive that I have in, running DOS. I can't find the hard drive anywhere! So anyways, after starting the setup process, it copied the files over to the "hard drive" (which took 16 hours because the version of DOS I ran couldn't run smartdrv.exe), and it said the computer had to reboot. So I let it reboot, and it stopped and said there is no boot device. So I popped in UBCD that I have installed on a flash drive, and I discovered that it had copied the Windows files over to the flash drive and not the hard drive. It never asked where it should extract the files... So I toyed around with UBCD, ran a memory test on the hard drive to make sure it was fine, and it came out clean. So I'm stuck now. How can I get this installed? Writing this, I came up with an idea. If I copy the DOS startup files over to the hard drive, would I be able to start DOS from it? If so, I believe that could fix my problems. Any help is greatly appreciated, because I am running out of ideas and am at my wits end with this computer.

    Read the article

  • USB mouse connecting and disconnecting randomly

    - by Kalec
    I've bought an acer aspire 5742G about 2 months ago or so and it's been running great, but sometimes I used to hear the windows error beep but I had no idea what was causing it since the "bug" was automatically fixed so fast I couldn't even see an error message (also it kinda always happened when I was busy also, either in a game or while doing my homework). Later on my mouse would simply not work for 3-5 seconds then work again, I thought nothing of it at the time. I also had a problem where it only worked in one usb and one only. To move it I had to remove the battery, unplug the laptop and hold the power button for 2 minutes to reset the bios settings. Since today though it went nuts. Sometimes it disconnects / reconnects 12 times in 10 seconds and windows just keeps beeping till I unplug it, then it runs smooth for 5-6 minutes then it goes nuts again. Other times it seems like it skips (disconnects for a fraction of a second) other times just for 2-3 seconds. But this is incredibly frustrating. Sometimes the power just goes down (the laser turns off) and well that at least I would understand but this is a rare occurrence. Now I know the usb ports work since I have a lot of other devices connected and I tried the mouse on a room m8's laptop so the mouse also works. My only conclusion is that it's an operating system / settings bug and / or problem (I have tried the mouse in all ports by the way). All drivers and bios are up to date (maybe except mouse but I can't seem to update that and the mouse has no name, just a serial number which helps with nothing. Still it worked till today and nothing should have changed any way). I have made sure windows can't shut it down to save power (in device management). Also I tried to delete the drivers and re-install them, rebooting and the power button trick but nothing. Most I have done is get rid of the 12 disconnects / reconnects every 10 seconds :) but that's all :( I would buy a new one but I'm afraid it might do the same thing. ****EDIT****** Tried the mouse again at a friend but now it didn't even install it's software nor did the update work. Think I'll just buy a new one but I'd still like a suggestion at least so I'll leave this open #### EDIT 2 Now it works again, I can't explain this. Still thinking of getting a new one though

    Read the article

  • How to move Mailboxes over from old Exchange 2007 to new EBS 2008 network?

    - by Qwerty
    This q is similar to: http://serverfault.com/questions/39070/how-to-move-exchange-2003-mailbox-or-store-from-2003-to-2007-on-separate-networks Basically I am trying to move our exchange mailboxes over to a test domain that is hosting EBS2008 with Exchange 2007. We plan to move as soon as we can when we have our exchange data over. I have tried moving a db with mailboxes over but cannot get it to mount in the new Exchange in any way possible, including mounting it onto a recovery store. From my understanding the ONLY prerequisite for moving Exchange DBs across is that it must have the same Organizational name (unlike previous versions of Exchange). If anyone has any insight as to why I cannot mount and simply reattach the mailboxes, please give me an idea as to what could be wrong. It should be as simple as this. Note that the DBs I have are in a clean state. I cannot use ExMerge because I am not running any mailboxes on 2003. I have also tried using a 32bit Vista machine with the Export-Mailbox cmdlet to extract mailboxes but anything I do to it results in Permission errors. I have tried to troubleshoot these with no success. I am running in full admin with proper exchange roles and yet it still gives me access denied errors: Export-Mailbox : MapiExceptionNetworkError: Unable to make admin interface conn ection to server. (hr=0x80040115, ec=-2147221227) Also some errors show in the management console: get-MailboxDatabase Completed Warning: ERROR: Could not connect to the Microsoft Exchange Information Store service on server TATOOINE.baytech.local. One of the following problems may be occurring: 1- The Microsoft Exchange Information Store service is not running. 2- There is no network connectivity to server TATOOINE.baytech.local. 3- You do not have sufficient permissions to perform this command. The following permissions are required to perform this command: Exchange View-Only Administrator and local administrators group for the target server. 4- Credentials have been cached for an unpriviledged user. Try removing the entry for this server from Stored User Names and Passwords. Why I have to use a 32bit machine to export a simple .pst file is beyond me... So yeah I am now out of ideas and any help would be great! Thanks in advance.

    Read the article

  • Why does Ubuntu 9.10 hang during boot at "Booting processor 1 APIC 0x1 ip 0x6000"?

    - by BraeburnDev
    I recently installed a new copy of Ubuntu 9.10 (Kernel 2.6.31-14) on to my Hp Pavilion dv6t, so I can setup a Linux development environment. The install went flawlessly and I proceeded with Ubuntu's udate manager's long list of updates (292 in all). I also setup a swap file and activated a Nvidia 185 driver for the Nvidia 260m GPU on the machine. After all this was done I restarted the computer and booted into Ubuntu this time with a newer 2.6.31-19 Kernel which was installed from the update manager. During booth the computer hung at this point: Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013136] Performance Counters: Nehalem/Corei7 events, Intel PMU driver. Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013141] ... version: 3 Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013142] ... bit width: 48 Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013144] ... generic counters: 4 Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013146] ... value mask: 0000ffffffffffff Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013147] ... max period: 000000007fffffff Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013149] ... fixed-purpose counters: 3 Feb 24 14:23:12 braeburn-laptop kernel: [ 0.013151] ... counter mask: 000000070000000f Feb 24 14:23:12 braeburn-laptop kernel: [ 0.015539] ACPI: Core revision 20090521 Feb 24 14:23:12 braeburn-laptop kernel: [ 0.052264] Setting APIC routing to flat Feb 24 14:23:12 braeburn-laptop kernel: [ 0.052639] ..TIMER: vector=0x30 apic1=0 pin1=2 apic2=-1 pin2=-1 Feb 24 14:23:12 braeburn-laptop kernel: [ 0.152580] CPU0: Intel(R) Core(TM) i7 CPU Q 720 @ 1.60GHz stepping 05 Feb 24 14:23:12 braeburn-laptop kernel: [ 0.270845] Booting processor 1 APIC 0x1 ip 0x6000 I can post a full kern.log of this boot process if requested. Hopefully this is enough information to go on. I should add that I'm still new to configuring and running a Linux OS although I know enough basic command line usage to do software development. This is my attempt to become more familiar with Linux and manage my own system. I'd like to get some insight on the nature of this system hang, what the problem is and how to resolve it. At this point I can scrap the install if I broke something, but my intuition says this is an issue with the kernel recognizing the correct hardware configuration for my system, or perhaps this is an issue with the APIC drivers managing Nehalem's new power management capabilities? Thanks for looking at this issue and providing feed back.

    Read the article

  • Planning trunk capacity for multiple GbE switches

    - by wuckachucka
    Without measuring throughput (it's at the top of the list; this is just theoretical), I want to know the most standard method for trunking VLANs on multiple Gigabit (GbE) switches to a core Layer 3 GbE switch. Say you have three VLANs: VLAN10 (10.0.0.0/24) Servers: your typical Windows DC/file server, Exchange, and an Accounting/SQL server. VLAN20: (10.0.1.0/24) Sales: needs access to everything on VLAN10; doesn't need access to VLAN30 and vice-versa. VLAN20: (10.0.1.0/24) Support: needs access to everything on VLAN10; doesn't need access to VLAN20 and vice-versa. Here's how I think this should work in my head: Switch #1: Ports 2-20 are assigned to VLAN20; all the Sales workstations and printers are connected here. Optional 10GbE combo port #1 is trunked to L3 switch's 10 GbE combo port #1. Switch #2: Ports 2-20 are assigned to VLAN30; all the Support workstations and printers are connected here. Optional 10GbE combo port #1 is trunked to L3 switch's 10 GbE combo port #2. Core L3 switch: Ports 2-10 are assigned to VLAN10; all three servers are connected here. With a standard 10/100 x 24 switch, it'll usually come with one or two 1 GbE uplink ports; carrying over this logic to a 10/100/1000 x 24, the "optional" 10 GbE combo ports that most higher-end switches can get shouldn't really be an option. Keep in mind I haven't tested anything yet, I'm primarily moving in this direction for growth (don't want to buy 10/100 switches and have to replace those within a couple of years) and security (being able to control access between VLANs with L3 routing/packet filtering ACLs). Does this sound right? Do I really need the 10 GbE ports? It seems very non-standard and expensive, but it "feels" right when you think about 40 or 50 workstations trunking up to the L3 switch over 1 GbE standard ports. If say 20 workstations want to download a 10 GB image from the servers concurrently, wouldn't the trunk be the bottleneck? At least if the trunk was 10 GbE, you'd have 10x1GbE nodes being able to reach their theoretical max. What about switch stacking? Some of the D-Links I've been looking at have HDMI interfaces for stacking. As far as I know, stacking two switches creates one logical switch, but is this just for management I/O or does the switches use the (assuming it's HDMI 1.3) 10.2 Gbps for carrying data back and forth?

    Read the article

  • CPU overheating after cleaning it

    - by Roberts
    I wanted to clean my computer CPU heatsink and fan itself, because the temperature is not what I wanted. About (50C ~ 70C). I have Intel Core 2 Duo E4300 @1.8 GHz (LGA775). The heatsink wasn't so scary filled with dust but I wanted to clean it anyway. I didn't know how to get heatsink with fan from the socket. So after 25 minutes I've figured it out. But I didn't know how to get it back on so I spent a lot time getting out the motherboard from the case. The fan and heatsink... The case and all components are clear of dust. (I'm tired now). Then I put all back just the way it was, well did few things on cable management. But the problem was that I didn't know how to connect front audio connectors. I had Windows XP hibernated. So I started the PC and everything was normal, except CMOS memory was clear. I configured the BIOS just the way it was and while I was doing that I saw about 58C CPU temperature and fan at 1789 RPM. Restarted the computer with new settings applied. But Windows halted with Blue Screen (I forgot what error it was but something with KERNEL). Restarted the PC and deleted hibernation session and everything was back normal. But couldn't record any sound from front panel microphone. The problem was that I messed ground wire with mic. Again after fixing it I turned computer on. No problems. The fan currently is noisy and temperature was 78C. The temperature before was 55C - 60C at idle. Now it's about 60C. If I do something then temperature raises to 79C. While speaking in skype the temperature was 82C. Could this problem occur because of the thermal grease (it's old and never replaced)? Edit The problem wasn't in thermal paste (because I didn't touch it). The problem was that I installed heatsink wrong. Now instead of regular 60C CPU temperature the CPU is at 48C (cool).

    Read the article

  • SQL 2008 R2 Named Instance Client Connectivity Issues?

    - by Jerry Dodge
    We're upgrading our software from using SQL 2000 to 2008 R2. Our customers will be installing an update which uninstalls 2000 and installs 2008 R2 under the same instance. So if no instance existed, then no instance name will be set (default). However, the problem starts with the customers which have a named SQL instance. Starting in 2008 R2 (not sure of ones before), for some reason, a client connecting to the server by its instance name is unsuccessful. I'm testing from the Management Studio - if I can't connect this, then nothing can connect. I browse network servers, and find the specific server\instance in the list. But, upon trying to connect to an instance name like MyServer\INST, I get: A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified) (Microsoft SQL Server, Error: -1) I do in fact have TCP/IP and Named Pipes protocols enabled, this is the first thing I did. When I connect to the server using a comma (,) and port number like MyServer, 49195, it works just fine. So it appears that client computers are just unable to identify the instance names. This has happened on all our installations of SQL 2008 R2 and from all client computers, including Win 7, XP, Vista, Server 2008, and Server 2003. We never experienced such issues on earlier versions of SQL. The problem even persists if the firewalls and antiviruses are all disabled. Now, this is a large update which we will be distributing soon to all our customers, and we want to minimize the interaction they need with us to get this installed. We absolutely hate the idea of using a port number, because it will always be different, and we would have to modify each client to point to this server/port. Some of our customers may have hundreds of client computers. How do I make client connections to a named SQL instance work again? After all, this is the whole purpose of named instances, and if a client can't connect to this instance by its name, then what is it even named for? EDIT It was mentioned to make sure SQL Browser is running, so I checked, and it is running. The server is also able to connect to its self (locally) - just external connections are refused. UPDATE After more careful checking, I learned the firewall wasn't completely disabled when testing, and upon disabling it completely, this works. So it appears that SQL Browser is being blocked by the firewall from external clients from accessing.

    Read the article

  • High I/O latency with software RAID, LUKS encrypted and LVM partitioned KVM setup

    - by aef
    I found out a performance problems with a Mumble server, which I described in a previous question are caused by an I/O latency problem of unknown origin. As I have no idea what is causing this and how to further debug it, I'm asking for your ideas on the topic. I'm running a Hetzner EX4S root server as KVM hypervisor. The server is running Debian Wheezy Beta 4 and KVM virtualisation is utilized through LibVirt. The server has two different 3TB hard drives as one of the hard drives was replaced after S.M.A.R.T. errors were reported. The first hard disk is a Seagate Barracuda XT ST33000651AS (512 bytes logical, 4096 bytes physical sector size), the other one a Seagate Barracuda 7200.14 (AF) ST3000DM001-9YN166 (512 bytes logical and physical sector size). There are two Linux software RAID1 devices. One for the unencrypted boot partition and one as container for the encrypted rest, using both hard drives. Inside the latter RAID device lies an AES encrypted LUKS container. Inside the LUKS container there is a LVM physical volume. The hypervisor's VFS is split on three logical volumes on the described LVM physical volume: one for /, one for /home and one for swap. Here is a diagram of the block device configuration stack: sda (Physical HDD) - md0 (RAID1) - md1 (RAID1) sdb (Physical HDD) - md0 (RAID1) - md1 (RAID1) md0 (Boot RAID) - ext4 (/boot) md1 (Data RAID) - LUKS container - LVM Physical volume - LVM volume hypervisor-root - LVM volume hypervisor-home - LVM volume hypervisor-swap - … (Virtual machine volumes) The guest systems (virtual machines) are mostly running Debian Wheezy Beta 4 too. We have one additional Ubuntu Precise instance. They get their block devices from the LVM physical volume, too. The volumes are accessed through Virtio drivers in native writethrough mode. The IO scheduler (elevator) on both the hypervisor and the guest system is set to deadline instead of the default cfs as that happened to be the most performant setup according to our bonnie++ test series. The I/O latency problem is experienced not only inside the guest systems but is also affecting services running on the hypervisor system itself. The setup seems complex, but I'm sure that not the basic structure causes the latency problems, as my previous server ran four years with almost the same basic setup, without any of the performance problems. On the old setup the following things were different: Debian Lenny was the OS for both hypervisor and almost all guests Xen software virtualisation (therefore no Virtio, also) no LibVirt management Different hard drives, each 1.5TB in size (one of them was a Seagate Barracuda 7200.11 ST31500341AS, the other one I can't tell anymore) We had no IPv6 connectivity Neither in the hypervisor nor in guests we had noticable I/O latency problems According the the datasheets, the current hard drives and the one of the old machine have an average latency of 4.12ms.

    Read the article

  • PDF Corruption When Sending with Microsoft Products

    - by Winner
    I have the same PDF corruption problem in two different offices that I am the tech support for. Office 1: Started in the middle of December. PDF received from outside the office and is viewable with no problems. I have no control over how it is created. If it is forwarded to anyone else, the PDF is corrupted. I have forwarded it to multiple people in the office. I have tried viewing with Reader 8, 9, Sumatra and Fox IT. I have tried forwarding to Gmail and their viewer says it is corrupted. If I save the PDF and create a new email, it will be corrupted when sent using Outlook 2003, Outlook 2007, Microsoft Live Mail and Outlook Express. If I create the email using Thunderbird 3, Gmail or the webclient Iclient for IPSwitch IMail it will not be corrupted. I have confirmed the same results when using our IMail SMTP and also Using Gmail as the SMTP server. To be clear, if I created in Thunderbird, Gmail or Iclient and received on any of the MS products, it will be viewable. This office receives PDFs daily from multiple sources. There is only a small subset that are having this problem. So far they problem PDFs are from two different companies they deal with, but not all of the PDFs are bad. Office 2: PDFs are created by a management system. I'm not sure what engine is used to create them. Same exact same issues. At both offices, I noticed that the file size is wrong. One small PDF the proper file size is 12kb for the PDF when it's viewable, when it shows up corrupted it is only 8kb. We handle the email for both offices. Both are POP servers, not Exchange. IMail was updated after these issues start. I have tried different SMTP servers and it still seems to happen only when using Microsoft products to send. Anyone else having problems with PDFs getting corrupted? Any ideas how to find out a resolution?

    Read the article

  • How to enable caching on Apache / Ubuntu Linux?

    - by Jim Mischel
    I have a large (several megabytes) XML file that's updated rather frequently (every 10 minutes or less) and gets a lot of traffic. I'd like to implement some caching to reduce bandwidth and server load. Looking at the Apache documents, I see a dizzying array of configuration options that involve various combinations of mod_expires, mod_headers, and mod_cache (and variants). I end up running in circles and the results aren't what I expect. I'm comfortable editing the various configuration files if I have some idea what I'm supposed to change. But at the moment I'm poking around in the dark and that's never a comfortable feeling. So, perhaps if I describe what I want, somebody here can take me by the hand and say, "This is what you need to do." Periodically, this file, call it "stuff.xml" is updated and a new version copied to the directory. The external url would be, for example, http://example.com/stuff.xml. Understand, this part works. Whenever I request the file, I get the expected result. But the file is big and I want to save bandwidth, so first I'd like to implement conditional GET semantics with the If-Modified-Since header. How do I do this? I've enabled mod_headers and mod_expired and added the <FilesMatching> section in my httpd.conf as recommended in countless examples I've seen online, but that didn't change the behavior when made a conditional GET request. I always get a status 200 with the entire document. So how the heck do I implement this? That'll cut down on neeless transfers. I'd also like to limit the amount of data transferred. Seeing as this is XML, gzipping it should save me 50% or more. My next step would be to somehow gzip the file and, if it's not too difficult, store it in memory. That'll cut down on per-access data transfer, and also reduce disk transfers. So how do I implement this type of caching? Thanks in advance.

    Read the article

  • Why does NX Client for Windows silently closes after connection?

    - by pavel
    Hey! I connect remotely to my Ubuntu server from Vista machine. Now I need to run a GUI application on the server (Wireshark). So I decided to use FreeNX server/client to view Ubuntu GUI on Vista I have successfully installed FreeNX on Ubuntu and NX Client on Vista. I was following this guide Unfortunately, now I found myself stuck with the following problem. At the client, the !M logo window appears, but after a few seconds that window just closes, even without showing any error message. Guys, I'm really stuck, please help! Maybe I should have installed some graphical environment on the server? These are the details from NX client, it seems there are no errors. ----------------- Info: Display running with pid '7768' and handler '0x670d24'. NXPROXY - Version 3.4.0 Copyright (C) 2001, 2007 NoMachine. See http://www.nomachine.com/ for more information. Info: Proxy running in client mode with pid '2168'. Session: Starting session at 'Sat Dec 19 10:58:35 2009'. Warning: Connected to remote version 3.3.0 with local version 3.4.0. Info: Connection with remote proxy completed. Info: Using WAN link parameters 768/24/1/0. Info: Using cache parameters 4/4096KB/16384KB/16384KB. Info: Using pack method 'adaptive-9' with session 'kde'. Info: Using ZLIB data compression 1/1/32. Info: Using ZLIB stream compression 1/1. Info: No suitable cache file found. Info: Forwarding X11 connections to display ':0'. Info: Listening to font server connections on port '11000'. Session: Session started at 'Sat Dec 19 10:58:35 2009'. Info: Established X server connection. Info: Using shared memory parameters 0/0K. Session: Terminating session at 'Sat Dec 19 10:58:37 2009'. Session: Session terminated at 'Sat Dec 19 10:58:37 2009'. -----------

    Read the article

  • What presentation software suits my needs?

    - by claws
    Background: I'm teaching biology to 12th grade students. The syllabus I'm teaching is huge. I mean literally, very huge. There is a lot for students to remember. There are no less than 1000 facts (weird names, dates etc) for students to remember. They'll have to remember all of them, they don't have a choice. The notes I compiled for their learning itself is upto 80 printed pages(Just the bullet outline & facts). That's just one chapter. We have 34 chapters. Also my students are very hardworking, they study upto 8-10hrs per day (Yeah! we are from India :). So, I want to ensure maximum retaining by the students at each and every stage (Teaching & Learning). I'm trying to as many memory training techniques as possible. I'm trying to incorporate, mnemonics, strong visual aids (pictures, 3D-animations, real videos etc.), spaced repetition etc. I think MS powerpoint is not suitable for my needs: There are about 200 slides per chapter. Its very easy for students to get lost while teaching. Because the problem with powerpoint is that it gives facts (as bullets) but it doesn't exploit the association & organization (Concept Map) of the content, which helps students learn quickly. I found an amazing software called XMind. You can see the screenshot here. Problem is that it is not as powerpoint in terms of powerpoint. This software can be used for just for concept maps. In the above screenshot, each topic occupies a single slide. I have an Image/picture(Detailed huge picture) and about 5-10 bullet points and probably a video or an animation of somethings. And this XMind is not good at presenting, in terms that it doesn't allow me to set what to present after what. I want to present a top down view, with a slide for each topic. PS: I Don't like prezi.com. I tried but it simply is too confusing for my students. It zooms here and there. I didn't tried it but I've seen few presentations.

    Read the article

  • Encoding multiple video streams with a single avconv invocation

    - by automatthias
    I played with avconv on Ubuntu and I'm now able to e.g. record the desktop with sound from a soundcard. One thing I wanted to do was recording two video inputs at the same time, for instance the desktop and from the webcam. I thought about doing something like this: avconv \ -f alsa \ -i default \ -acodec flac \ -f video4linux2 \ -r 6 \ -i /dev/video0 \ -f x11grab \ -i :0.0 \ out.mkv My thinking was that if you define multiple video inputs, and the .mkv format can handle multiple video streams, avconv will encode 2 video streams and 1 audio stream into one file. But this isn't what happens: avconv version 0.8.4-6:0.8.4-0ubuntu0.12.10.1, Copyright (c) 2000-2012 the Libav developers built on Nov 6 2012 16:51:11 with gcc 4.7.2 [alsa @ 0x1091bc0] capture with some ALSA plugins, especially dsnoop, may hang. [alsa @ 0x1091bc0] Estimating duration from bitrate, this may be inaccurate Input #0, alsa, from 'default': Duration: N/A, start: 1354364317.020350, bitrate: N/A Stream #0.0: Audio: pcm_s16le, 48000 Hz, 2 channels, s16, 1536 kb/s [video4linux2 @ 0x10923e0] Estimating duration from bitrate, this may be inaccurate Input #1, video4linux2, from '/dev/video0': Duration: N/A, start: 100607.724745, bitrate: 29491 kb/s Stream #1.0: Video: rawvideo, yuyv422, 640x480, 29491 kb/s, 6 tbr, 1000k tbn, 6 tbc [x11grab @ 0x107b2a0] device: :0.0+83,87 -> display: :0.0 x: 83 y: 87 width: 854 height: 480 [x11grab @ 0x107b2a0] shared memory extension found [x11grab @ 0x107b2a0] Estimating duration from bitrate, this may be inaccurate Input #2, x11grab, from ':0.0+83,87': Duration: N/A, start: 1354364318.488382, bitrate: 196761 kb/s Stream #2.0: Video: rawvideo, bgra, 854x480, 196761 kb/s, 15 tbr, 1000k tbn, 15 tbc Incompatible pixel format 'bgra' for codec 'mpeg4', auto-selecting format 'yuv420p' [buffer @ 0x107fcc0] w:854 h:480 pixfmt:bgra [avsink @ 0x10bdf00] auto-inserting filter 'auto-inserted scaler 0' between the filter 'src' and the filter 'out' [scale @ 0x10dc680] w:854 h:480 fmt:bgra -> w:854 h:480 fmt:yuv420p flags:0x4 Output #0, matroska, to '.../out.mkv': Metadata: encoder : Lavf53.21.0 Stream #0.0: Video: mpeg4, yuv420p, 854x480, q=2-31, 4000 kb/s, 1k tbn, 15 tbc Stream #0.1: Audio: libvorbis, 48000 Hz, 2 channels, s16 Stream mapping: Stream #2:0 -> #0:0 (rawvideo -> mpeg4) Stream #0:0 -> #0:1 (pcm_s16le -> libvorbis) Press ctrl-c to stop encoding [mpeg4 @ 0x10bd800] rc buffer underflow ^Cframe= 160 fps= 15 q=2.0 Lsize= 3414kB time=10.66 bitrate=2623.0kbits/s video:3273kB audio:131kB global headers:4kB muxing overhead 0.165600% Received signal 2: terminating. I'm not sure if it's the question of mapping (some -map options to add?) or that avconv just can't encode more than 1 video stream at one time. So is it an actual avconv limitation, or a limitation of the available containers, or me simply not finding the right combination of command line options?

    Read the article

  • How to force Debian to boot new Kernel?

    - by ThE_-_BliZZarD
    I'm running Debian 6, Debian GNU/Linux, with Linux 2.6.32-5-amd64 under Grub2 ( 1.98+20100804-14+squeeze1) on a remote system (no possibility to view the pre-boot messages). I compiled and installed a new kernel, but I can not get it to boot. What I have done: Installed the packages via: dpkg -i linux-headers-3.5.3.20120914-amd64_3.5.3.20120914-amd64-10.00.Custom_amd64.deb linux-image-3.5.3.20120914-amd64_3.5.3.20120914-amd64-10.00.Custom_amd64.deb This updated the Grub configuration. My /boot/grub/grub.cfg now contains: menuentry 'Debian GNU/Linux, with Linux 3.5.3.20120914-amd64' --class debian --class gnu-linux --class gnu --class os { insmod raid insmod mdraid insmod part_msdos insmod part_msdos insmod ext2 set root='(md0)' search --no-floppy --fs-uuid --set 5a3882a9-c7df-4f6a-9feb-f03e3e37be01 echo 'Loading Linux 3.5.3.20120914-amd64 ...' linux /vmlinuz-3.5.3.20120914-amd64 root=UUID=003242b5-121b-49f3-b32f-1b40aea56eed ro acpi=ht quiet panic=10 echo 'Loading initial ramdisk ...' initrd /initrd.img-3.5.3.20120914-amd64 } menuentry 'Debian GNU/Linux, with Linux 2.6.32-5-amd64' --class debian --class gnu-linux --class gnu --class os { insmod raid insmod mdraid insmod part_msdos insmod part_msdos insmod ext2 set root='(md0)' search --no-floppy --fs-uuid --set 5a3882a9-c7df-4f6a-9feb-f03e3e37be01 echo 'Loading Linux 2.6.32-5-amd64 ...' linux /vmlinuz-2.6.32-5-amd64 root=UUID=003242b5-121b-49f3-b32f-1b40aea56eed ro acpi=ht quiet panic=10 echo 'Loading initial ramdisk ...' initrd /initrd.img-2.6.32-5-amd64 } I used grub-set-default "Debian GNU/Linux, with Linux 2.6.32-5-amd64" to set the old kernel as default and then grub-reboot "Debian GNU/Linux, with Linux 3.5.3.20120914-amd64" to boot into the new kernel once. After update-grub I rebooted the system, but everytime it comes back up with the old kernel (2.6). I tried setting the new one as default (grub-set-default 0, update-grub, reboot) but, still the old one. The Syslogs contain NO hint whatsoever about trying to boot the new kernel - only the old one. Would there be any hints regarding problems with a kernel? Is there a way to enable debug-logging in grub? What am I doing wrong? How can I force the system to boot the new kernel? Edit: Hardware of remote machine. CPU cat /proc/cpuinfo processor : 0 vendor_id : AuthenticAMD cpu family : 16 model : 5 model name : AMD Athlon(tm) II X4 605e Processor stepping : 3 cpu MHz : 2294.898 cache size : 512 KB physical id : 0 siblings : 4 core id : 0 cpu cores : 4 apicid : 0 initial apicid : 0 fpu : yes fpu_exception : yes cpuid level : 5 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt pdpe1gb rdtscp lm 3dnowext 3dnow constant_tsc rep_good nonstop_tsc extd_apicid pni monitor cx16 popcnt lahf_lm cmp_legacy svm extapic cr8_legacy abm sse4a misalignsse 3dnowprefetch osvw ibs skinit wdt bogomips : 4589.77 TLB size : 1024 4K pages clflush size : 64 cache_alignment : 64 address sizes : 48 bits physical, 48 bits virtual power management: ts ttp tm stc 100mhzsteps hwpstate (copied only the first, 3 more follow) The server is a Fujitsu PRIMERGY MX130 S1.

    Read the article

< Previous Page | 850 851 852 853 854 855 856 857 858 859 860 861  | Next Page >