Search Results

Search found 20219 results on 809 pages for 'network monitoring'.

Page 99/809 | < Previous Page | 95 96 97 98 99 100 101 102 103 104 105 106  | Next Page >

  • Route all traffic of home network through VPN [migrated]

    - by user436118
    I have a typical semi advanced home network scenario: A cable modem - eth A wireless router (netgear n600) eth and wlan A home server (Running ubuntu 12.04 LTS, connected over wlan) A bunch of wireless clients (wlan) Lying around I have anoher cheaper wlan router, and two different USB wlan NIC's that are known to work with Linux. ACTA struck. I want to route ALL of my WAN traffic through a remote server through a VPN. For sake of completition, lets say there is a remote server running debian sqeeze where a VPN server is to be installed. The network is then to behave so that if the VPN is not operative, it is separated from the outside world. I am familiar with general system/network practices, but lack the specific detailed knowledge to accomplish this. Please suggest the right approach, packages and configurations you'd use to reach said solution. I've also envisioned the following network configuration, please improve it if you see fit: Client ip:10.1.1.x nm:255.0.0.0 gw:10.1.1.1 reached via WLAN Wlan router 1: ip: 10.1.1.1 nm:255.0.0.0 gw: 10.10.10.1 reached via ETH Homeserver: <<< VPN is initiated here, and the other endpoint is somewhere on the internet. eth0: ip:10.10.10.1 nm: 0.0.0.0 gw:192.168.0.1 reached via WLAN Homeserver: wlan0: ip: 192.168.0.2 nm: 255.255.255.0 gw: 192.168.0.1 reached via WLAN Wlan router 2: ip: 192.168.0.1 nm: 0.0.0.0 gw: set via dhcp uplink connector: cable modem Cable Modem: Remote DHCP. Has on-board DHCP server for ethernet device that connects to it, and only works this way. All this WLAN fussery is because my home server is located in a part of the house where a cable link isnt possible unfortunately.

    Read the article

  • Best way to say "sync all system clocks to this server, when and ONLY when I say so?" Mixed setup of Windows+Linux servers.

    - by twblamer
    Title pretty much explains it. Let's say there's 100 servers, various versions of Windows and Linux, and one Windows server is the "master clock." I did look at this question: How do I synchronize clocks between Linux and Windows? This hints that ntp can do what I want if I run "ntpd -q" on a client (?). If I install ntp I also need to guarantee that it will only sync the times when I force it to. Even better if I have a log that tells me every time a sync was performed. I'm doing benchmark runs and I need to be able to say something like this: "Clocks were synced on all the benchmark systems at 09:42:01am on the master. A benchmark run was then initiated and allowed to run for six hours. None of the system clocks were altered during this time interval." I understand there is subsequent clock drift, but for now that's the way we're doing things and I'm doing it with a manual process. I'd rather at least automate the one-time sync.

    Read the article

  • How to monitor a Windows process' working set greater than 4GB?

    - by Shoeless
    Apparently the .NET framework has a bug that prevents working set values above 2GB from accurately being determined. Between 2 and 4GB one can apply some xor-ing calculation to obtain the value, but there's no means of obtaining working set values greater than 4GB (using .Net or WMI) What method can be used - preferably from a PowerShell script - to obtain an accurate measurement of a process' working set when the working set is greater than 4GB? (some side details can be found in this StackOverflow question)

    Read the article

  • Virtual machine shows no network adapter

    - by Logman
    I had a an old Lotus/Domino server (R5), I just virtualized. It ran Windows 2000 server. I had to use Vmware Converter v3.x to create the vm because it was the only one I could find that could actually do a Win2k machine that had no service packs. It was just put out to pasture a couple months ago, so it isn't being used except to store the old email for archiving. It took a bit of work to get it onto the Win2008R2 servers hyper-v but I got it there. Problem now, is that the network adapter didn't show up. I could not install the guest additions because it needed sp4 + on win2k... so I installed sp4 onto the vm guest. Everything seems fine except the network adapter still isn;t showing up in device manager. NOthing. Now this server had an external ip, and I did not want it to be put onto the internal virtual network. I am going to use a dedicated adapter on the host (hyper-v server) if that matters... but this shouldn't matter if the the guests network adapter doesn't show at all. Thoughts?

    Read the article

  • Windows 7 computer apparently connected to working wireless network but can't access router page or internet

    - by Hemmer
    I can consistently connect successfully to both the router and the internet using both my phone and two different computers which strongly suggests that the issue is at the desktop end. Only my Windows 7 desktop machine has stopped getting internet connectivity. It manages to connect to the router's network using the Windows 7 wireless dialog, but can't access either the router configuration page (192.168.1.1) or the internet in general once connected. The strange thing is the wireless network icon in the notification bar shows a full strength signal, sometimes with the yellow warning triangle. The output of ipconfig /all is: Wireless LAN adapter Wireless Network Connection: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Broadcom 802.11g Network Adapter Physical Address. . . . . . . . . : 00-12-17-94-98-90 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes IPv4 Address. . . . . . . . . . . : 192.168.1.102(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.0 Lease Obtained. . . . . . . . . . : 08 June 2011 10:32:16 Lease Expires . . . . . . . . . . : 08 June 2011 12:32:16 Default Gateway . . . . . . . . . : 192.168.1.1 DHCP Server . . . . . . . . . . . : 192.168.1.1 DNS Servers . . . . . . . . . . . : 194.168.4.100 194.168.8.100 NetBIOS over Tcpip. . . . . . . . : Enabled I've tried renewing DCHP settings disabling IPv6 resetting TCP stack uninstalling and reinstalling WLAN card drivers I've not installed anything new or made any changes to my knowledge, this just happened out of the blue. The only possible change is my friend connected his macbook to the network, but that has gone now and shouldn't have any lasting effects? TCP/IPv4 is set to automatically find an IP address. Antivirus is MSE (up to date) and doesn't detect anything unusual. Any ideas where to go next? Any help is greatly appreciated. For reference, the results of ipconfig /all on one of the working computers is: Ethernet adapter Wireless Network Connection: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Broadcom 802.11g Network Adapter Physical Address. . . . . . . . . : 00-16-CF-67-E5-97 Dhcp Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes IP Address. . . . . . . . . . . . : 192.168.1.100 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : 192.168.1.1 DHCP Server . . . . . . . . . . . : 192.168.1.1 DNS Servers . . . . . . . . . . . : 194.168.4.100 194.168.8.100 Lease Obtained. . . . . . . . . . : 08 June 2011 10:26:38 Lease Expires . . . . . . . . . . : 08 June 2011 12:26:38 UPDATE: Still not working, but I've managed to find a temporary workaround by tethering my Android phone, effectively becoming a new wifi adapter. Will be moving to a new flat so will test if it is a network specific thing - maybe the card has got damaged somehow? Also will see if the card is working with Linux soon.

    Read the article

  • Accessing temperature data on ESXi5.1?

    - by Ovesh
    For ESXi5.1 (VMWare vSphere) images, I can see temperature data on the vSphere user interface (under Monitor / Hardware Status). I tried scouring the available snmp data using snmpwalk, but can't find the data anywhere in there. Maybe I'm missing something. Does anybody know the right MIB for temperature data? Otherwise, ow can that data be accessed? By the way, this is a machine installed from an image provided by HP.

    Read the article

  • Setting thresholds via smartd.conf

    - by JPerkSter
    Hello! We currently use smartd to monitor SMART health on our disks. I would like to set the 'thresholds' that smartd uses to report. For example: 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 9 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 9 I would like to be able to set a threshold for these two attributes to only report if they are above 10. I haven't been able to find a way to set this via smartd.conf, and I'm also not looking to actually shutdown the daemon. Has anyone ever tried this, or know how I might be able to accomplish this better then throwing a script into cron.hourly?

    Read the article

  • Simplest way to respawn configured number of instances of a specific process.

    - by Zwei Steinen
    So we have an app. which we wan to run multiple instance of it in linux. The number should be configurable. We also want that whenever one of the instance disappears, a new one is booted up. I was looking into C based programs, shell script, python script etc. but I was wondering what would be the most simple, easiest way to do it. Are there any tools out there? Can one simply use some linux built-in functionality? Linux distribution is Red Hat.

    Read the article

  • How can I find out what modifications a program’s installer makes?

    - by Gregory MOUSSAT
    I want to know what some installers do: mainly what files, folders, and registry entries they add, remove, or modify. Lots of “ professional” programs are so poorly documented that it’s difficult to find the proper way to configure them, update them, etc. InstallRite is a program which is able to take a “snapshot” before and after the installation of a program and then compare the snapshots. This allows you to know what was done and even to create a custom uninstaller. Unfortunately InstallRite seems to no longer be maintained and has not been updated since 2008.

    Read the article

  • What Warning and Critical values to use for check_load?

    - by Sandra
    Right now I am using these values: # y = c * p / 100 # y: nagios value # c: number of cores # p: wanted load procent # 4 cores # time 5 minutes 10 minutes 15 minutes # warning: 90% 70% 50% # critical: 100% 80% 60% command[check_load]=/usr/local/nagios/libexec/check_load -w 3.6,2.8,2.0 -c 4.0,3.2,2.4 But these values are just picked almost random. Does anyone have some tested values?

    Read the article

  • How to manage enterprise network of Linux machines?

    - by killy9999
    I work at the university. In my institute we have six computer laboratories used for teaching. Each lab has almost 20 computers, which gives over 100 machines total. Computers have either Windows XP or Windows 7 Eneterprise operating system. We use Symantec Ghost to manage all the computers. Each computer has a Ghost client installed, which allows to control computers over network. Every six months we restore a master image on one of the computers in a lab, update that image and distribute it over the network to all computers in a laboratory. Thanks to Ghost client this is done automatically with just a few clicks. Recently I suggested that it would be good to have Linux installed in the laboratories. The administrators were concerned that we would not be able to manage that many computers if each would have to be updated manually. The question is: how to manage such a huge network of Linux machines in an automated way? To make the description of our network more complete I'll add that all students have their accounts (about few thousand users) on a central server. These are accessed via LDAP. To use a computer in laboratory each student has to log in using his own account.

    Read the article

  • Private subnet for VM server host-only network

    - by Derek Pressnall
    At my current job, we distribute a product based on a Linux server with multiple VMs defined (using KVM / libvirt). We are planning to expose limited ports to the customer's network, and use iptables to direct inbound traffic to the appropriate internal VM. My question: is there a class of private subnets that I can use for the internal host-only network that is least likely to conflict with a client IP subnet? Specifically, if I choose a /24 out of any of the RFC-1918 defined private subnets (such as 192.168.x.x), there is a chance of conflicting with a customer-used range. I noticed that several current VM implementations default to 192.168.122.x -- is this due to an RFC that I'm not familiar with, and therefore this is a safe range to use (that most network admins would avoid)? Or did the various VM vendors just pick that range randomly? I guess I'm looking for an IP range that is more private than the existing private (RFC1918) addresses. The only other thought I had was to use one of the "Test Net" IP ranges reserved for documentation purposes (RFC 5737). Note, that I'm not worried about a customer's network blocking these IPs, as this is only internal to our server (packets get NATted before leaving the box). However this does seem more unorthodox than just sticking with the default 192.168.122.x/24 subnet.

    Read the article

  • Recommend a desktop app to monitor port 80 on servers

    - by busyone
    Hello, I did some googling but was unsuccessful, so I am posting here. I am looking to get an app (preferably free/open source) to monitor my servers on port 80 that would send me an email/text when some predefined timeout triggers. I could probably write something in VB to do this but i am burried with projects, why reinvent the wheel. I know there are services out there that want you to pay $5/month to do so, I was thinking about a Windows app that would sit on my computer and simply monitor predefined list of IPs on port 80. Thanks!

    Read the article

  • Can I use Server Monitor with a non-server Mac?

    - by Chris
    I have a computer I use as a simple file and web server. I am simply desiring to be able to monitor load, traffic, memory usage, etc via Server Monitor. I have also downloaded an app for my iPhone which does the same thing, but it uses the same protocol that Server Monitor does. Is it possible to get Server Monitor to recognize my non-server box as a server so I can monitor this information? For reference, I am running 10.4.11 on this PPC box. Thanks in advance!

    Read the article

  • How can I monitor URLs being requested by components in web apps running in Internet Explorer?

    - by Tahtah
    Hi I'm using a particular web app which for some strange reason runs only in IE and not in Firefox. I need to see which URLs are being fetched by internal components in the web app, such as AJAX requests and video sources being loaded in a video player. In Firefox I would have used Firebug... is there any tool I can use to see (not necessarily in real time or with a nice GUI) which URLs were requested by IE? Thanks

    Read the article

  • Network using only switches

    - by mschultz
    So I'm not a network guy - but here's what I want to do - I have an existing network using wifi, which I like, and which is used to connect several computers to the internet. It is headed up by a router, which is in another part of the building. Three of those computers are in my office. All three have gigabit wired ethernet. I have a gigabit switch. Here's what I want to do: Build a 2nd network, out of just that switch, which allows all 3 computers to connect to each other (just to each other is fine, for this purpose, they need no internet). I have a distributed computing task (rendering high-quality fractal artwork, as it were), that requires the best connection speed to all 3 computers. I want them to be able to "talk to each other" as quickly as possible, with the fewest dropped packets (the dataflow over this network will be quite high). So how do I do this. I'm not a networking guy at all - I tried connecting them all, and nobody got an IP address (which I assume is because nobody is running a DNS server?). What all do I need to do to make this work? PS - two are running windows, one is running ubuntu.

    Read the article

  • vmware network installation problem

    - by shantanu
    After installation from vmware_bunddle it shows network device error during configuration(First run). Log File: 2012-04-03T20:01:24.881+06:00| vthread-3| I120: Log for VMware Workstation pid=5766 version=8.0.2 build=build-591240 option=Release 2012-04-03T20:01:24.881+06:00| vthread-3| I120: The process is 64-bit. 2012-04-03T20:01:24.881+06:00| vthread-3| I120: Host codepage=UTF-8 encoding=UTF-8 2012-04-03T20:01:24.881+06:00| vthread-3| I120: Host is Linux 3.2.0-19-generic Ubuntu precise (development branch) 2012-04-03T20:01:24.880+06:00| vthread-3| I120: Msg_Reset: 2012-04-03T20:01:24.880+06:00| vthread-3| I120: [msg.dictionary.load.openFailed] Cannot open file "/usr/lib/vmware/settings": No such file or directory. 2012-04-03T20:01:24.880+06:00| vthread-3| I120: ---------------------------------------- 2012-04-03T20:01:24.880+06:00| vthread-3| I120: PREF Optional preferences file not found at /usr/lib/vmware/settings. Using default values. 2012-04-03T20:01:24.880+06:00| vthread-3| I120: Msg_Reset: 2012-04-03T20:01:24.880+06:00| vthread-3| I120: [msg.dictionary.load.openFailed] Cannot open file "/root/.vmware/config": No such file or directory. 2012-04-03T20:01:24.880+06:00| vthread-3| I120: ---------------------------------------- 2012-04-03T20:01:24.880+06:00| vthread-3| I120: PREF Optional preferences file not found at /root/.vmware/config. Using default values. 2012-04-03T20:01:24.880+06:00| vthread-3| I120: Msg_Reset: 2012-04-03T20:01:24.880+06:00| vthread-3| I120: [msg.dictionary.load.openFailed] Cannot open file "/root/.vmware/preferences": No such file or directory. 2012-04-03T20:01:24.880+06:00| vthread-3| I120: ---------------------------------------- 2012-04-03T20:01:24.881+06:00| vthread-3| I120: PREF Failed to load user preferences. 2012-04-03T20:01:24.881+06:00| vthread-3| W110: Logging to /tmp/vmware-root/modconfig-5766.log 2012-04-03T20:01:25.200+06:00| vthread-3| I120: modconf query interface initialized 2012-04-03T20:01:25.201+06:00| vthread-3| I120: modconf library initialized 2012-04-03T20:01:25.269+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.278+06:00| vthread-3| I120: Validating path /lib/modules/preferred/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:25.278+06:00| vthread-3| I120: Failed to find /lib/modules/preferred/build/include/linux/version.h 2012-04-03T20:01:25.278+06:00| vthread-3| I120: Failed version test: /lib/modules/preferred/build/include/linux/version.h not found. 2012-04-03T20:01:25.278+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:25.284+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.306+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.355+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:01:25.355+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:25.362+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.383+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.434+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:01:25.502+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.507+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.511+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.516+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.521+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.561+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.566+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.571+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.576+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.581+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.586+06:00| vthread-3| I120: Validating path /lib/modules/preferred/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:25.586+06:00| vthread-3| I120: Failed to find /lib/modules/preferred/build/include/linux/version.h 2012-04-03T20:01:25.586+06:00| vthread-3| I120: Failed version test: /lib/modules/preferred/build/include/linux/version.h not found. 2012-04-03T20:01:25.586+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:25.593+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.614+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.663+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:01:25.740+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.747+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.752+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.757+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.762+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:25.767+06:00| vthread-3| I120: Validating path /lib/modules/preferred/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:25.767+06:00| vthread-3| I120: Failed to find /lib/modules/preferred/build/include/linux/version.h 2012-04-03T20:01:25.767+06:00| vthread-3| I120: Failed version test: /lib/modules/preferred/build/include/linux/version.h not found. 2012-04-03T20:01:25.767+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:25.772+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.792+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:25.843+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:01:26.838+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:26.848+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:26.853+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:26.858+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:26.863+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:28.460+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:28.460+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:28.466+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:28.488+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:28.542+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:01:28.542+06:00| vthread-3| I120: Building module vmmon. 2012-04-03T20:01:28.553+06:00| vthread-3| I120: Extracting the sources of the vmmon module. 2012-04-03T20:01:28.615+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmmon-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:01:36.499+06:00| vthread-3| I120: Installing module vmmon from /tmp/vmware-root/modules/vmmon.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:01:36.507+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vmmon.ko 2012-04-03T20:01:58.314+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:01:58.315+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:01:58.336+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:58.379+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:01:58.431+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:01:58.431+06:00| vthread-3| I120: Building module vmnet. 2012-04-03T20:01:58.431+06:00| vthread-3| I120: Extracting the sources of the vmnet module. 2012-04-03T20:01:58.541+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmnet-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:02:05.973+06:00| vthread-3| I120: Failed to compile module vmnet! 2012-04-03T20:02:05.984+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:02:05.984+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:02:05.990+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:02:06.015+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:02:06.067+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:02:06.067+06:00| vthread-3| I120: Building module vmblock. 2012-04-03T20:02:06.067+06:00| vthread-3| I120: Extracting the sources of the vmblock module. 2012-04-03T20:02:06.141+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmblock-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:02:13.531+06:00| vthread-3| I120: Installing module vmblock from /tmp/vmware-root/modules/vmblock.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:02:13.532+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vmblock.ko 2012-04-03T20:02:19.090+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:02:19.090+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:02:19.097+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:02:19.117+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:02:19.173+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:02:19.173+06:00| vthread-3| I120: Building module vmci. 2012-04-03T20:02:19.174+06:00| vthread-3| I120: Extracting the sources of the vmci module. 2012-04-03T20:02:19.284+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmci-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:02:28.525+06:00| vthread-3| I120: Installing module vmci from /tmp/vmware-root/modules/vmci.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:02:28.526+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vmci.ko 2012-04-03T20:02:31.760+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:02:31.760+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:02:31.766+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:02:31.786+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:02:31.838+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:02:31.838+06:00| vthread-3| I120: Building module vmci. 2012-04-03T20:02:31.839+06:00| vthread-3| I120: Extracting the sources of the vmci module. 2012-04-03T20:02:31.864+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmci-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:02:33.684+06:00| vthread-3| I120: Building module vsock. 2012-04-03T20:02:33.685+06:00| vthread-3| I120: Extracting the sources of the vsock module. 2012-04-03T20:02:33.809+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vsock-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:02:41.050+06:00| vthread-3| I120: Installing module vsock from /tmp/vmware-root/modules/vsock.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:02:41.051+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vsock.ko 2012-04-03T20:03:02.757+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.762+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.767+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.771+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.776+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.782+06:00| vthread-3| I120: Validating path /lib/modules/preferred/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:03:02.782+06:00| vthread-3| I120: Failed to find /lib/modules/preferred/build/include/linux/version.h 2012-04-03T20:03:02.782+06:00| vthread-3| I120: Failed version test: /lib/modules/preferred/build/include/linux/version.h not found. 2012-04-03T20:03:02.782+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:03:02.790+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:02.814+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:02.865+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:03:02.958+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.968+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.973+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.978+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:02.983+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:04.372+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:04.372+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:03:04.378+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:04.399+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:04.452+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:03:04.452+06:00| vthread-3| I120: Building module vmmon. 2012-04-03T20:03:04.452+06:00| vthread-3| I120: Extracting the sources of the vmmon module. 2012-04-03T20:03:04.486+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmmon-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:03:05.976+06:00| vthread-3| I120: Installing module vmmon from /tmp/vmware-root/modules/vmmon.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:03:05.977+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vmmon.ko 2012-04-03T20:03:09.056+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:09.057+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:03:09.065+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:09.090+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:09.142+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:03:09.142+06:00| vthread-3| I120: Building module vmnet. 2012-04-03T20:03:09.142+06:00| vthread-3| I120: Extracting the sources of the vmnet module. 2012-04-03T20:03:09.169+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmnet-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:03:12.072+06:00| vthread-3| I120: Failed to compile module vmnet! 2012-04-03T20:03:12.090+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:12.090+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:03:12.098+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:12.121+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:12.179+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:03:12.179+06:00| vthread-3| I120: Building module vmblock. 2012-04-03T20:03:12.179+06:00| vthread-3| I120: Extracting the sources of the vmblock module. 2012-04-03T20:03:12.205+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmblock-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:03:15.340+06:00| vthread-3| I120: Installing module vmblock from /tmp/vmware-root/modules/vmblock.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:03:15.341+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vmblock.ko 2012-04-03T20:03:18.451+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:18.451+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:03:18.457+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:18.480+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:18.531+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:03:18.531+06:00| vthread-3| I120: Building module vmci. 2012-04-03T20:03:18.531+06:00| vthread-3| I120: Extracting the sources of the vmci module. 2012-04-03T20:03:18.569+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmci-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:03:19.787+06:00| vthread-3| I120: Installing module vmci from /tmp/vmware-root/modules/vmci.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:03:19.789+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vmci.ko 2012-04-03T20:03:22.933+06:00| vthread-3| I120: Trying to find a suitable PBM set for kernel 3.2.0-19-generic. 2012-04-03T20:03:22.933+06:00| vthread-3| I120: Validating path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic 2012-04-03T20:03:22.939+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:22.959+06:00| vthread-3| I120: Your GCC version: 4.6 2012-04-03T20:03:23.009+06:00| vthread-3| I120: Header path /lib/modules/3.2.0-19-generic/build/include for kernel release 3.2.0-19-generic is valid. 2012-04-03T20:03:23.009+06:00| vthread-3| I120: Building module vmci. 2012-04-03T20:03:23.009+06:00| vthread-3| I120: Extracting the sources of the vmci module. 2012-04-03T20:03:23.034+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vmci-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:03:24.227+06:00| vthread-3| I120: Building module vsock. 2012-04-03T20:03:24.227+06:00| vthread-3| I120: Extracting the sources of the vsock module. 2012-04-03T20:03:24.254+06:00| vthread-3| I120: Building module with command: /usr/bin/make -j -C /tmp/vmware-root/modules/vsock-only auto-build SUPPORT_SMP=1 HEADER_DIR=/lib/modules/3.2.0-19-generic/build/include CC=/usr/bin/gcc GREP=/usr/bin/make IS_GCC_3=no VMCCVER=4.6 2012-04-03T20:03:26.125+06:00| vthread-3| I120: Installing module vsock from /tmp/vmware-root/modules/vsock.o to /lib/modules/3.2.0-19-generic/misc. 2012-04-03T20:03:26.126+06:00| vthread-3| I120: Registering file: /usr/lib/vmware-installer/2.0/vmware-installer --register-file vmware-vmx regular /lib/modules/3.2.0-19-generic/misc/vsock.ko My System details: cpu : AMD APU dual core E450 ram: 2GB ubuntu: 12.04 (64 bit) I have downloaded Latest vmware version. Thanks in advance

    Read the article

  • Two network adapters on Ubuntu Server 9.10 - Can't have both working at once?

    - by Rob
    I'm trying to set up two network adapters in Ubuntu (server edition) 9.10. One for the public internet, the other a private LAN. During the install, I was asked to pick a primary network adapter (eth0 or eth1). I chose eth0, gave the installer the details listed below in the contents of /etc/network/interfaces, and carried on. I've been using this adapter with these setting for the last few days, and every thing's been fine. Today, I decide it's time to set up the local adapter. I edit the /etc/network/interfaces to add the details for eth1 (see below), and restart networking with sudo /etc/init.d/networking restart. After this, attempting to ping the machine using it's external IP address fails, but I can ping it's local IP address. If I bring eth1 down using sudo ifdown eth1, I can successfully ping the machine via it's external IP address again (but obviously not it's internal IP address). Bringing eth1 back up returns us to the original problem state: external IP not working, internal IP working. Here's my /etc/network/interfaces (I've removed the external IP information, but these settings are unchanged from when it worked) rob@rhea:~$ cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # The primary (public) network interface auto eth0 iface eth0 inet static address xxx.xxx.xxx.xxx netmask xxx.xxx.xxx.xxx network xxx.xxx.xxx.xxx broadcast xxx.xxx.xxx.xxx gateway xxx.xxx.xxx.xxx # The secondary (private) network interface auto eth1 iface eth1 inet static address 192.168.99.4 netmask 255.255.255.0 network 192.168.99.0 broadcast 192.168.99.255 gateway 192.168.99.254 I then do this: rob@rhea:~$ sudo /etc/init.d/networking restart * Reconfiguring network interfaces... [ OK ] rob@rhea:~$ sudo ifup eth0 ifup: interface eth0 already configured rob@rhea:~$ sudo ifup eth1 ifup: interface eth1 already configured Then, from another machine: C:\Documents and Settings\Rob>ping [external ip] Pinging [external ip] with 32 bytes of data: Request timed out. Request timed out. Request timed out. Request timed out. Ping statistics for [external ip]: Packets: Sent = 4, Received = 0, Lost = 4 (100% loss), Back on the Ubuntu server in question: rob@rhea:~$ sudo ifdown eth1 ... and again on the other machine: C:\Documents and Settings\Rob>ping [external ip] Pinging [external ip] with 32 bytes of data: Reply from [external ip]: bytes=32 time<1ms TTL=63 Reply from [external ip]: bytes=32 time<1ms TTL=63 Reply from [external ip]: bytes=32 time<1ms TTL=63 Reply from [external ip]: bytes=32 time<1ms TTL=63 Ping statistics for [external ip]: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms So... what am I doing wrong?

    Read the article

  • Can't attach EC2 instance to Network Interface

    - by Ian Warburton
    When trying to attach a network interface, it says... No instances were found for this availability zone. My instance is in us-east-1c and my network interface is in us-east-1b. Is that significant? If so, how do I create the VPC in the same zone and if not then why this error? EDIT: I've re-created the VPC and the Network Interface is now us-east-1c and the EC2 instance is also us-east-1c. Same error message though!

    Read the article

  • Installing Win7 over PXE through Serva fails on Loading Network Resources

    - by Armand
    Trying to install Win7 OS to a Lenovo E335 with no DVD/CD. I have to do it either over PXE/Network or USB. Although I am able to get passt the installation menu of Serva, it fails on Loading Network Resources ... FAILED No NIC/Driver, ABORTING! This is the only log on the Serva Client PC and nothing on the Serva-server. Would appreciate if someone can tell me how to go pass this error. THe network card works fine, it has already loaded the Windows installation structure on a X: drive on the new laptop. Another detail: I am using a normal Ethernet Cable to connect the PCs. Should this be enough or a crossover cable is a must in this case?

    Read the article

  • "No active network adapters found" Hyper-V 2008 R2

    - by mnemosyn
    I fiddled around with the virtual network settings of my Hyper-V server, because Windows Update failed to run in the VMs. I set the flag that makes the NIC exclusively usable by the VM. Now, the host system tells me it has no active network adapters. What does that even mean? According to netsh, there are three enabled network connections. I tried to restart the NICs using devcon.exe (the correct x64 version), but that doesn't make any difference - still, devcon reports the NICs are there and they are activated?! Is there any way I can force the host to re-enable the NICs?

    Read the article

  • WOL for Asus M5A97 built in Realtek Network Adapter

    - by madphp
    I cant get wake on lan to work for my built in network adapter. Its a ASUS M5A97 motherboard, and the network adapter is a Realtek PCIe GBE. I have Shutdown WakeOnLan - Enabled Wake on Magic Packet - Enabled Wake on Pattern Match - Enabled WOL & Shutdown Link Speed - 10 Mbps First I have set up a magic packet client to listen, and the packet is getting through. I have also checked these in Power Management for the network adapter. Allow the computer to turn off this device to save power Allow this device to wake the computer Allow a magic packet to wake the computer.

    Read the article

  • Windows - Use Local Service and/or Network Service account for a windows service

    - by user19185
    I've created a window's service that monitors files on a specific directory on our Windows OS. When a file is detected, the service does some file I/O, reads the files, creates sub-directories, etc. This service also uses database connectivity to connect to another server. My plan is to have the service run as the default "Local Service" account. Since I need to allow write/read privileges, which apparently the "Local Service" account does not do by default, I'm going to explicitly set "Full Control" privileges for the "Local Service" account on the folder that I'm reading/writing to and from. I believe the above is a good . My question is, for the folder that I'm reading and writing to, do I need to setup a "Network Service" role with full control access? I'm wondering since my service uses database connectivity to another server, if I'll need the "Network Service" account setup. I may be misunderstanding what the "Network Service" account does.

    Read the article

  • Need help diagnosing network performance issues

    - by tokes
    I am currently working in a developing country as a system analyst for a government department. My area of expertise is software projects, but I've come across a few issues with the network setup in my office. (Unfortunately, being a developing country, there's not a lot of professional help available for this sort of thing.) Most recently, I am trying to diagnose a problem with slowness on the network. Our office is connected to the internet via an ADSL wireless modem/router (called Router). The modem is connected via ethernet to a switch (called Switch). The modem also acts as a wireless access point (called Wireless1), though because it is in a room at the end of the floor, it's range is limited. There are ethernet ports installed around the office. The cables of these all lead back to the same switch. In closer vicinity to the bulk of the client computers, there is another wireless router that acts as an access point for those clients (called Wireless2). That router is connected via ethernet to a wall port, and therefore to Switch. There is also a Windows server which acts as a DNS server (called DNSBox) which is located in the same room and is connected directly to Switch. ---Internet----------| Router/Wireless1 192.168.10.1 ---------------| |----|=========| DNSBox | |-------------------- 192.168.10.4 --------------------| Switch |---Other clients---- | |-------------------- |----|=========| Wireless2 ------------------| 192.168.10.198 One final thing to mention about the network setup. All clients are configured with manual IP addresses. Their router/gateway is set to the IP address of Router, and their DNS server is set to the IP address of DNSBox (with a secondary IP set to an external IP - that of our ISP's DNS server). Here are the symptoms we are experiencing: Clients connected to Wireless2 AP experience slow and unstable connections to the internet. (Slow here is defined as speeds of ~1KB/s, though ping response times seem to be as normal.) Clients connected via ethernet to Switch also experience the same slowness. Clients connected to Wireless1 AP (i.e. connecting via wireless directly to the ADSL modem) experience normal connections to the internet. Clients connected via ethernet to Router (i.e. connecting via ethernet directly to the ADSL modem) also experience normal connections to the internet. I also tried to gauge the connection performance between two machines on the network via ethernet: A file transfer between two clients who were both directly connected to Switch was the fastest; A file transfer between one client directly connected to Switch, and one client directly connected to Router (which is directly connected to Switch) performed much slower; A file transfer between two clients directly connected to Router also performed slowly. Things I have attempted to diagnose the problem: Restarted Switch -- no change. We tried unplugging ethernet jacks from Switch 4 at a time and testing the internet connection. The thought here was that perhaps a client on the network has contracted a virus, and is possibly spamming the network with traffic? (Not very technical, I know.) Unfortunately we couldn't get any significant increases in performance using this method. There were a couple of times when it seemed to be better, but then the connection speed quickly dropped back to slow/dead pace. I didn't want to unplug all jacks from Switch because I was concerned that users might be affected or that I would re-plug in the jacks incorrectly (should I even be worried about that? a port is a port on a switch, right?) I tried swapping the ethernet cable used to connect Router to Switch -- no change in performance. I tried swapping the port used on Switch for Router -- no change in performance. Anyone got any ideas on what this could be? Should I be mentioning specific brand names/models of the hardware used? Virii outbreaks are common in this country/office -- what could I be doing to figure out if a virus is at fault? If it is a virus, it doesn't seem to be generating a lot of traffic to/from the internet, because a) I can still get a good speed if I am directly connected to Router / Wireless1 and b) our ISP data usage has not risen suspiciously. Thanks for your help! Update #1 Here are the specs of some of the hardware: Switch is an Edimax ES3132RL 32-Port 10/100 Rackmount Switch Router is a D-Link DSL-G604T Update #2 I just tried unplugging everything except a laptop and Router from Switch. Speeds are still slow. I guess that means that Router / Switch are not being flooded? It seems more and more likely that the cause is something to do with the interaction between Router and Switch. However, I still can't find any useful resources on setting the LAN speed for either (and I'm not well-versed in these advanced networking configurations).

    Read the article

< Previous Page | 95 96 97 98 99 100 101 102 103 104 105 106  | Next Page >