Search Results

Search found 119 results on 5 pages for 'lsi'.

Page 1/5 | 1 2 3 4 5  | Next Page >

  • Ubuntu doesn't detect drives conected to LSI "Host Bus Adapter"

    - by dvrecmfo
    I purchased LSI SAS 9300-4i Host Bus Adapter, from card bios I can see that it detected all hard drives connected to it, but from ubuntu I can't see them. What I've tried: Installed the driver provided here http://www.lsi.com/products/host-bus-adapters/pages/lsi-sas-9300-4i.aspx#tab/tab3 (I tried both LINUX_RH_SL_OEL_CTX_MPT_GEN3_C0_Phase2.0-3.00.00.00-1 and Linux_Driver_RHEL5-6_SLES10-11_P1) lspci | grep -i lsi 07:00.0 Serial Attached SCSI controller: LSI Logic / Symbios Logic SAS3004 PCI-Express Fusion-MPT SAS-3 (rev 02)

    Read the article

  • Intel 520 SSD drives not working with lsi controller on VMware esxi 5

    - by Michael
    We have a problem with our LSI 9266 controller. LSI have vmware drivers which normally show the health status of connected drives, raid controller, battery etc from within the vSphere Client. This driver also allows connectivity from the LSI MSM utility from a windows workstation. The problem is as soon as I connect my intel 520 SSD drives the health status in the vsphere client disappears, also we lose connectivity via the LSI MSM utlity. Any other drives we test are fine, 1TB SAS drives, other SSD drives etc are all OK. The Intel drives are on the compatability list and are supported by LSI but dont work with the VMware driver. If I install a windows OS on the physical server we have no problems. I have logged a ticket with LSI but they havent been very helpful. I am trying to find other people that may have had the same issue and maybe even a fix

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • LSI 9211-8i won't boot in KVM

    - by Paul McMillan
    I'm running ubuntu 11.04 with an LSI 9211-8i in IT mode with the latest firmware (10). I'm using KVM with VT-d enabled to pass the entire PCIe device through to the guest OS. I have the device disabled in the system BIOS. When I boot my virtual machine, the adapter quits during bios initialization with the following error: Unable to load LSI Corporation MPT BIOS MPT BIOS Fault 0Ch encountered at adapter PCI(00h,04h,00h) Press any key to continue... I know the virtualization is correctly enabled. I've blacklisted the kernel modules in the host OS. Has anyone else encountered this error? I'm about out of ideas here. Edit: I contacted LSI tech support about this, and they suggested that I try RedHat and Xen. Apparently they don't test or support anything else.

    Read the article

  • LSI SAS 1064E drivers for Server 2012

    - by rendentucson
    I have a need to place Windows Server 2012 onto a Sunfire X4100 blade server that contains a LSI SAS 1064e RAID controller (2006). The LSI site only has drivers up to server 2008 R2. I did attempt to install server 2012 hoping it might contain generic MS Drivers (I was dreaming, I know). That failed. I attempted to load external LSI drivers for server 2008. That failed as well. Am I out of luck, or did I miss something? Thanks in advance.

    Read the article

  • All paths down on vSphere esxi 5.1, LSI 9211-8i

    - by user1434058
    Works 100% ESXi 5.1 HBA (LSI 1064e) 1x SAS2 100GB SSD Doesn't work ESXi 5.1 HBA (LSI 9211-8i IT /IBM M1015) 1x SAS2 100GB SSD After a few hours of heavy HD load i get: - Device or filesystem with identifier ['all drives'] has entered the All Paths Down state. - ESXi retries but loses connectivity to the SAS drive, marks it as "dead or error" - reboot fixes the issue How can i fix this issue?

    Read the article

  • How to understand the LSI HBA connector specs?

    - by Sandra
    When reading the specifications for the LSi SAS 9206-16e HBA, it says Storage Connectivity; Data Transfer Rates * 16 ports; 6Gb/s SAS 2.1 compliant SAS Bandwidth * Half Duplex 2400MB/s, x4, 6Gb/s SAS lanes Port Configurations * 16 ea, x1 ports (individual drives) * 4 ea, x4 wide ports * 2ea, x8 wide ports Connectors * Four (x4) mini-SAS HD external connectors (SFF8644) So there are 4 physical connectors. Question What is the bandwidth for each of the connectors? I would be temped to say 6Gb/s * 4, but then it mentions the "Port Configurations" and 2ea, 4ea, 16ea, which I don't understand what is. Does this mean, that the 4 physical connectors are not identical?

    Read the article

  • LSI RAID monitor reports "Consistency Check inconsistency logging disabled"

    - by carlpett
    I have a server with a LSI MegaRAID 9261-8i controller. Recently I started getting alerts like this one: Controller ID: 1 Consistency Check inconsistency logging disabled, too many inconsistencies on VD: 0 Generated on:Sat May 12 04:06:40 2012 SYSTEM DETAILS--- IP Address: 192.168.1.29 OS Name: Windows 7 x64 OS Version: 6.01 Driver Name: megasas.sys Driver Version: 4.5.1.64 IMAGE DETAILS--- BIOS Version: 2.120.33-1197 Firmware Package Version: 12.12.0-0045 Firmware Version: 3.21.00_4.11.05.00_0x05000000 VD 0 is a RAID mirror containing the system disk. I have searched and read, but cannot find any trace of how to actually do anything about this. I tried running a scandisk but that did not find anything (as I expected, since scandisk reads the disks as exposed by the controller, right?). The MegaRAID Storage Manager does not as far as I can see have any options for checking or fixing physical disks. The program claims the VD is "healty", and both disks have Error count 0. Also a bit strange is the System details in the message... The IP address is associated with the RAS (dial in) interface, and the OS should be Windows Server 2011 SBS. Has anyone else experienced this before? What can be done?

    Read the article

  • Strange performance issue with Dell R7610 and LSI 2208 RAID controller

    - by GregC
    Connecting controller to any of the three PCIe x16 slots yield choppy read performance around 750 MB/sec Lowly PCIe x4 slot yields steady 1.2 GB/sec read Given same files, same Windows Server 2008 R2 OS, same RAID6 24-disk Seagate ES.2 3TB array on LSI 9286-8e, same Dell R7610 Precision Workstation with A03 BIOS, same W5000 graphics card (no other cards), same settings etc. I see super-low CPU utilization in both cases. SiSoft Sandra reports x8 at 5GT/sec in x16 slot, and x4 at 5GT/sec in x4 slot, as expected. I'd like to be able to rely on the sheer speed of x16 slots. What gives? What can I try? Any ideas? Please assist Cross-posted from http://en.community.dell.com/support-forums/desktop/f/3514/t/19526990.aspx Follow-up information We did some more performance testing with reading from 8 SSDs, connected directly (without an expander chip). This means that both SAS cables were utilized. We saw nearly double performance, but it varied from run to run: {2.0, 1.8, 1.6, and 1.4 GB/sec were observed, then performance jumped back up to 2.0}. The SSD RAID0 tests were conducted in a x16 PCIe slot, all other variables kept the same. It seems to me that we were getting double the performance of HDD-based RAID6 array. Just for reference: maximum possible read burst speed over single channel of SAS 6Gb/sec is 570 MB/sec due to 8b/10b encoding and protocol limitations (SAS cable provides four such channels).

    Read the article

  • Very poor SCSI hd performance on IBM x336 with LSI 1030 RAID1

    - by David Tschoepe
    I'm experiencing very poor performance on an IBM x336 server with dual 73GB 15k hard drives on a U320 controller, LSI 1030. We're getting maybe 3.5MB/sec max (per HD Tune utility). It should be over 100MB/sec at least, I would think (another x335 box is running 70-80MB/sec). The server was recently setup and didn't really notice the problem, but may have been there from the beginning, so not sure. I have installed the IBM ServerRAID Windows utility. The server is running Windows 2008 R2 Web edition (if that matters). I thought maybe one of the drives was bad, so far I have removed one of the drives out of the array and tested again, but still the same results. I'm waiting for the RAID1 to resync and I will try pulling the other drive next. I've also used the ServerRAID utility but haven't noticed anything in there that might indicate a problem. Not sure if I'm on the right path here. So looking for some advice to track this down.

    Read the article

  • Dell 2970 - HP 1/8 G2 autoloader keeps falling off LSI 2032 SCSI chain

    - by middaparka
    I've a somewhat irritating problem with a Dell 2970 that has a HP 1/8 G2 autoloader (the Ultrium LTO 2 model) attached to the Dell/LSI 2032 non-RAID SCSI card. In essence, sometimes the autoloader/drive completely fails to appear on the SCSI chain (i.e.: there's neither a media changer or tape drive present within the device manager) and sometimes it appears but then subsequently disappears at a seemingly random (yet always inconvenient) time, resulting in backup failures. On most occasions, there are simply no errors logged in the system event log, but I did manage to capture a series of LSI_SCSI event ID 11 ("The driver detected a controller error on \Device\RaidPort0") errors followed by an event ID 129, ("Reset to device, \Device\RaidPort0, was issued") error during testing. I've tried two different cables, both with the same effect – sometimes the autoloader appears (for a while), sometimes it's completely absent. There's only one terminator I've tried to use, but as I've since successfully tested the autoloader on multiple occasions (albeit via a Adaptec U160 card on a different machine), my gut feel is that the issue doesn't lie with the terminator, or indeed the autoloader itself. As such, I'm just wondering if anyone has any ideas? It's most likely not relevant, but this is all under Windows SBS 2008, running Backup Exec 12.5 SBS edition (the Dell version), both fully patched. Addidtionally, the autoloader is running the latest firmware. It's been a while since I've dealt with anything SCSI, so all suggestions will be gratefully, gratefully received.

    Read the article

  • LSI SAS 9240-8i on Ubuntu 12.04 Hangs on Modprobe

    - by Francois Stark
    I used the LSI 9240-8i card on a smaller Intel motherboard with no problems in Ubuntu, with ZFS. However, we rebuilt the server to allow for more disks, using the ASROCK X79 Extreme 11 motherboard. It has 7 PCIe slots, and a LSI 2008 on-board. At first I thought the LSI 9240, when plugged in to PCIe, clashed with the on-board LSI 2008. Every time I plugged in the LSI 9240, modprobe would hang. Then I completely disabled the on-board LSI 2008, and the problem persisted. Last night it booted perfectly ONCE - all LSI cards and connected disks visible... However, all subsequent reboots failed. Both LSI cards' bios scans appear and they both see the disks connected to them, but Ubuntu modprobe hangs. Some selected dmesg lines, with both LSI cards enabled: [ 190.752100] megasas: [ 0]waiting for 1 commands to complete [ 195.772071] megasas: [ 5]waiting for 1 commands to complete [ 200.792079] megasas: [10]waiting for 1 commands to complete [ 205.812078] megasas: [15]waiting for 1 commands to complete [ 210.832037] megasas: [20]waiting for 1 commands to complete [ 215.852077] megasas: [25]waiting for 1 commands to complete [ 220.872072] megasas: [30]waiting for 1 commands to complete [ 225.892078] megasas: [35]waiting for 1 commands to complete [ 230.912086] megasas: [40]waiting for 1 commands to complete [ 235.932075] megasas: [45]waiting for 1 commands to complete [ 240.306157] usb 2-1.5: USB disconnect, device number 7 [ 240.952076] megasas: [50]waiting for 1 commands to complete [ 240.960034] INFO: task modprobe:233 blocked for more than 120 seconds. [ 240.960055] "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. [ 240.960067] modprobe D ffffffff81806200 0 233 146 0x00000004 [ 240.960075] ffff880806ae3b48 0000000000000086 ffff880806ae3ae8 ffffffff8101adf3 [ 240.960083] ffff880806ae3fd8 ffff880806ae3fd8 ffff880806ae3fd8 0000000000013780 [ 240.960090] ffffffff81c0d020 ffff880806acae00 ffff880806ae3b58 ffff880808961720 [ 240.960096] Call Trace: [ 240.960107] [<ffffffff8101adf3>] ? native_sched_clock+0x13/0x80 [ 240.960116] [<ffffffff816579cf>] schedule+0x3f/0x60 [ 240.960137] [<ffffffffa00093f5>] megasas_issue_blocked_cmd+0x75/0xb0 [megaraid_sas] [ 240.960144] [<ffffffff8108aa50>] ? add_wait_queue+0x60/0x60 [ 240.960154] [<ffffffffa000a6c9>] megasas_get_seq_num+0xd9/0x260 [megaraid_sas] [ 240.960164] [<ffffffffa000ab31>] megasas_start_aen+0x31/0x60 [megaraid_sas] [ 240.960174] [<ffffffffa00136f1>] megasas_probe_one+0x69a/0x81c [megaraid_sas] [ 240.960182] [<ffffffff813345bc>] local_pci_probe+0x5c/0xd0 [ 240.960189] [<ffffffff81335e89>] __pci_device_probe+0xf9/0x100 [ 240.960197] [<ffffffff8130ce6a>] ? kobject_get+0x1a/0x30 [ 240.960205] [<ffffffff81335eca>] pci_device_probe+0x3a/0x60 [ 240.960212] [<ffffffff813f5278>] really_probe+0x68/0x190 [ 240.960217] [<ffffffff813f5505>] driver_probe_device+0x45/0x70 [ 240.960223] [<ffffffff813f55db>] __driver_attach+0xab/0xb0 [ 240.960227] [<ffffffff813f5530>] ? driver_probe_device+0x70/0x70 [ 240.960233] [<ffffffff813f5530>] ? driver_probe_device+0x70/0x70 [ 240.960237] [<ffffffff813f436c>] bus_for_each_dev+0x5c/0x90 [ 240.960243] [<ffffffff813f503e>] driver_attach+0x1e/0x20 [ 240.960248] [<ffffffff813f4c90>] bus_add_driver+0x1a0/0x270 [ 240.960255] [<ffffffffa001e000>] ? 0xffffffffa001dfff [ 240.960260] [<ffffffff813f5b46>] driver_register+0x76/0x140 [ 240.960266] [<ffffffffa001e000>] ? 0xffffffffa001dfff [ 240.960271] [<ffffffff81335b66>] __pci_register_driver+0x56/0xd0 [ 240.960277] [<ffffffffa001e000>] ? 0xffffffffa001dfff [ 240.960286] [<ffffffffa001e09e>] megasas_init+0x9e/0x1000 [megaraid_sas] [ 240.960294] [<ffffffff81002040>] do_one_initcall+0x40/0x180 [ 240.960301] [<ffffffff810a82fe>] sys_init_module+0xbe/0x230 [ 240.960307] [<ffffffff81661ec2>] system_call_fastpath+0x16/0x1b [ 240.960314] INFO: task scsi_scan_7:349 blocked for more than 120 seconds.

    Read the article

  • PARTNER News: Tips and Guidelines from Avago (formerly LSI)

    - by Zeynep Koch
    In this blog write-up we would like to focus our attention to one of our IHV partners, Avago (formerly LSI) . Avago and Oracle have been collaborating at many levels for many years.  At the lowest level, Avago and Oracle engineer solutions to inbox advanced features in our I/O device drivers.  We collaborate to test, verify and optimize these drivers in Oracle Linux with Unbreakable Enterprise Kernel. Both LSI Nytro and Sun F-Series PCIe flash devices are supported inbox in Oracle Linux with Unbreakable Enterprise Kernel. By collaborating early in the engineering design cycle we can find and resolve issues sooner and deliver to the end-customer a fully optimized platform for I/O efficiency and data protection.  Hear more about the partnership and benefits in this podcast  LSI and Oracle Partnership. Avago had also been working on technical whitepaper and video whiteboard to explain some of the optimizations you can achieve by using smart flash cache with Oracle Linux.  Technical Paper: Improve Database Performance Using Sun Flash Accelerator Card, Database Smart Flash Cache and Oracle Linux Video: Improving DB Performance with Database Smart Flash Cache If you want more information about the partnership and product benefits, you can visit the LSI Oracle alliance page. 

    Read the article

  • Benefits of LSI Based SEO

    SEO or Search engine optimization is the largely talked regarding Internet technology these days, with online business houses basking under its glory. It is a method of optimizing a website with an extensive combination of tasks that will perk up websites charisma on the different search engines. To make the job simpler, a new tool has been introduced by the SEO experts that came to be identified as LSI or latent semantic indexing. The LSI has changed the world of search engine optimization.

    Read the article

  • LSI 9260-8i w/ 6 256gb SSDs - RAID 5, 6, 10, or bad idea overall?

    - by Michael Pearson
    We're provisioning a new production server for our reasonably busy website. Our choice of host have available a 6 drive configuration with a LSI 9260-8i card. My initial thought was to fill all six bays with SSDs (Intel 520 256gb) and set them up in RAID. Good, bad, or terrible idea? Can the card handle it? Should we be using RAID 5, 6 or 10? This would be the first time the provider have filled all six slots for this rackmount with SSDs, so they're a bit hesitant. I'm wondering if somebody else with this card has done something similar in a production environment. We do about 43gb of writes per day and currently use about 300gb of storage. The server acts as webserver, database, and image store for approx 1 million files. The plan is to underprovision the SSDs by approximately 10% to 20% to increase their overall lifespan & performance. The fallback option is 2x480gb SSDs in RAID 1 and another 2x1TB HDDs in RAID 1. The motivation behind this is that the server rental cost difference between 2xSSDs and 6xSSDs is minimal (compared to the overall cost of the rental). We do not have any special high-IOPs requirements. However, if the configuration is known to work, I don't see a good reason to not use it and not have to worry about having separate 'fast and small' and 'slow and large' disks.

    Read the article

  • LSI RAID-on-chip with RAID6 over two SAS links goes red when HDD enclosure is powered cycled; how to recover?

    - by GregC
    I have a RAID6 array managed by LSI 9286-8e card. I also have Sans Digital 24-bay NexentaSTOR JBOD enclosure with SAS extender built-in. They are connected to separate UPS devices. Normally, I'd shut down the PC, leaving RAID6 in healthy state. But today the power to JBOD enclosure was cut but PC kept running. After restarting the PC, all disks in RAID6 have lit up RED, and the only option in LSI MegaRAID manager app was to reset each disk to unassigned, thereby loosing all data on RAID6 array. Thankfully, I am only testing, but how would I recover if this were to happen in production?

    Read the article

  • Monitor LSI 3ware raid controller on ESXi

    - by aseq
    This concerns a server that runs ESXi (v. 4.x or 5.x) installed on drives that are configured into a raid10 using an LSI 3ware 97050 raid controller. I would like to know if there is a way to monitor the LSI 3ware series of controllers, in particular the 9750, through ESXi. And to hopefully also run the monitoring daemon LSI provides. I know you can set up a cronjob to execute tw_cli through ssh on the ESXi server. However that's not really ideal. I am not using vcenter by the way. It would be nice to have more than just monitoring working, since the 3ware software has a very useful web client, besides tw_cli.

    Read the article

  • Migrating RAID6 array from HP SmartArray P600 to LSI MegaRAID SAS 8888ELP

    - by MLu
    My customer has an external RAID6 array (8x 1TB in HP MSA60 enclosure) attached to HP SmartArray P600 controller. They have now decided to replace the server and the new one comes with LSI MegaRAID SAS 8888ELP. The HW supplier insists the migration is as simple as pulling the eSATA cable from P600 and inserting it into LSI but I'm not convinced. Unfortunately I have nowhere to test, and will have to do the exercise on the production array :( So the question in brief - is it possible to import the HP SmartArray P600-created RAID6 array to LSI MegaRAID 8888ELP?

    Read the article

  • Connecting XRAID to Sunfire via LSI FC card - Drives not showing up

    - by Matthew Watson
    Hi, I've got a Sunfire T1000 machine ( Solaris 10 10/09 s10s_u8wos_08a SPARC ) with a LSI7404EP-LC fibre channel card in it. This is plugged into an XRAID. The system seems to have picked up the card > /usr/platform/`uname -i `/sbin/prtdiag IO Location Type Slot Path Name Model ----------- ----- ---- --------------------------------------------- ------------------------- --------- MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/NET0 PCIE MB /pci@7c0/pci@0/network@4 network-pci14e4,1668 MB/NET1 PCIE MB /pci@7c0/pci@0/network@4,1 network-pci14e4,1668 MB/NET2 PCIX MB /pci@7c0/pci@0/pci@8/network@1 network-pci108e,1648 MB/NET3 PCIX MB /pci@7c0/pci@0/pci@8/network@1,1 network-pci108e,1648 MB/PCIX PCIX MB /pci@7c0/pci@0/pci@8/scsi@2 scsi-pci1000,50 LSI,1064 However it doesn't seem to be able to see the xraid attached to it, lsiutil only reports the onboard SAS controller. > /usr/local/bin/lsiutil ~ LSI Logic MPT Configuration Utility, Version 1.62, January 14, 2009 1 MPT Port found Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC 1. mpt0 LSI Logic SAS1064 A3 105 010a0000 0 Select a device: [1-1 or 0 to quit] I've tried adding the configuration to /kernal/drv/sd.conf and /kernal/drv/ssd.conf as per this thread, however format still cannot see any drives on the xraid. I'm not sure where to go next. Any suggestions? From what I've read..this should pretty much just eb plug it in and they show up in format..

    Read the article