  • How do I browse a Websphere MQ message without removing it?

    - by jmgant
    I'm writing a .NET Windows Forms application that will post a message to a Websphere MQ queue and then poll a different queue for a response. If a response is returned, the application will partially process the response in real time. But the response needs to stay in the queue so that a daily batch job, which also reads from the response queue, can do the rest of the processing. I've gotten as far as reading the message. What I haven't been able to figure out is how to read it without removing it. Here's what I've got so far. I'm an MQ newbie, so any suggestions will be appreciated. And feel free to respond in C#. Public Function GetMessage(ByVal msgID As String) As MQMessage Dim q = ConnectToResponseQueue() Dim msg As New MQMessage() Dim getOpts As New MQGetMessageOptions() Dim runThru = Now.AddMilliseconds(CInt(ConfigurationManager.AppSettings("responseTimeoutMS"))) System.Threading.Thread.Sleep(1000) 'Wait for one second before checking for the first response' While True Try q.Get(msg, getOpts) Return msg Catch ex As MQException When ex.Reason = MQC.MQRC_NO_MSG_AVAILABLE If Now > runThru Then Throw ex System.Threading.Thread.Sleep(3000) Finally q.Close() End Try End While Return Nothing 'Should never reach here' End Function NOTE: I haven't verified that my code actually removes the message. But that's how I understand MQ to work, and that appears to be what's happening. Please correct me if that's not the default behavior.

    Read the article

  • Debug.Assert-s use the same error message. Should I promote it to a static variable?

    - by Hamish Grubijan
    I love Asserts and code readability but not code duplication, and in several places I use a Debug.Assert which checks for the same condition like so: Debug.Assert(kosherBaconList.SelectedIndex != -1, "An error message along the lines - you should not ever be able to click on edit button without selecting a kosher bacon first."); This is in response to an actual bug, although the actual list does not contain kosher bacon. Anyhow, I can think of two approaches: private static readonly mustSelectKosherBaconBeforeEditAssertMessage = "An error message along the lines - you should not ever be able to " + "click on edit button without selecting a something first."; ... Debug.Assert( kosherBaconList.SelectedIndex != -1, mustSelectKosherBaconBeforeEditAssertMessage) or: if (kosherBaconList.SelectedIndex == -1) { AssertMustSelectKosherBaconBeforeEdit(); } ... [Conditional("DEBUG")] private void AssertMustSelectKosherBaconBeforeEdit() { // Compiler will optimize away this variable. string errorMessage = "An error message along the lines - you should not ever be able to " + "click on edit button without selecting a something first."; Debug.Assert(false, errorMessage); } or is there a third way which sucks less than either one above? Please share. General helpful relevant tips are also welcome.

    Read the article

  • Want to Receive dynamic length data from a message queue in IPC?

    - by user1089679
    Here I have to send and receive dynamic data using a SysV message queue. so in structure filed i have dynamic memory allocation char * because its size may be varies. so how can i receive this type of message at receiver side. Please let me know how can i send dynamic length of data with message queue. I am getting problem in this i posted my code below. send.c /*filename : send.c *To compile : gcc send.c -o send */ #include <stdio.h> #include <stdlib.h> #include <errno.h> #include <string.h> #include <sys/types.h> #include <sys/ipc.h> #include <sys/msg.h> struct my_msgbuf { long mtype; char *mtext; }; int main(void) { struct my_msgbuf buf; int msqid; key_t key; static int count = 0; char temp[5]; int run = 1; if ((key = ftok("send.c", 'B')) == -1) { perror("ftok"); exit(1); } printf("send.c Key is = %d\n",key); if ((msqid = msgget(key, 0644 | IPC_CREAT)) == -1) { perror("msgget"); exit(1); } printf("Enter lines of text, ^D to quit:\n"); buf.mtype = 1; /* we don't really care in this case */ int ret = -1; while(run) { count++; buf.mtext = malloc(50); strcpy(buf.mtext,"Hi hello test message here"); snprintf(temp, sizeof (temp), "%d",count); strcat(buf.mtext,temp); int len = strlen(buf.mtext); /* ditch newline at end, if it exists */ if (buf.mtext[len-1] == '\n') buf.mtext[len-1] = '\0'; if (msgsnd(msqid, &buf, len+1, IPC_NOWAIT) == -1) /* +1 for '\0' */ perror("msgsnd"); if(count == 100) run = 0; usleep(1000000); } if (msgctl(msqid, IPC_RMID, NULL) == -1) { perror("msgctl"); exit(1); } return 0; } receive.c /* filename : receive.c * To compile : gcc receive.c -o receive */ #include <stdio.h> #include <stdlib.h> #include <errno.h> #include <sys/types.h> #include <sys/ipc.h> #include <sys/msg.h> struct my_msgbuf { long mtype; char *mtext; }; int main(void) { struct my_msgbuf buf; int msqid; key_t key; if ((key = ftok("send.c", 'B')) == -1) { /* same key as send.c */ perror("ftok"); exit(1); } if ((msqid = msgget(key, 0644)) == -1) { /* connect to the queue */ perror("msgget"); exit(1); } printf("test: ready to receive messages, captain.\n"); for(;;) { /* receive never quits! */ buf.mtext = malloc(50); if (msgrcv(msqid, &buf, 50, 0, 0) == -1) { perror("msgrcv"); exit(1); } printf("test: \"%s\"\n", buf.mtext); } return 0; }

    Read the article

  • JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue

    - by John-Brown.Evans
    JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue ol{margin:0;padding:0} .c11_4{vertical-align:top;width:129.8pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c9_4{vertical-align:top;width:207pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt}.c14{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c17_4{vertical-align:top;width:129.8pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c7_4{vertical-align:top;width:130pt;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c19_4{vertical-align:top;width:468pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c22_4{background-color:#ffffff} .c20_4{list-style-type:disc;margin:0;padding:0} .c6_4{font-size:8pt;font-family:"Courier New"} .c24_4{color:inherit;text-decoration:inherit} .c23_4{color:#1155cc;text-decoration:underline} .c0_4{height:11pt;direction:ltr} .c10_4{font-size:10pt;font-family:"Courier New"} .c3_4{padding-left:0pt;margin-left:36pt} .c18_4{font-size:8pt} .c8_4{text-align:center} .c12_4{background-color:#ffff00} .c2_4{font-weight:bold} .c21_4{background-color:#00ff00} .c4_4{line-height:1.0} .c1_4{direction:ltr} .c15_4{background-color:#f3f3f3} .c13_4{font-family:"Courier New"} .c5_4{font-style:italic} .c16_4{border-collapse:collapse} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:bold;padding-bottom:0pt} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:11pt;font-family:"Arial";padding-bottom:0pt} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:10pt;font-family:"Arial";padding-bottom:0pt} This post continues the series of JMS articles which demonstrate how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue In this example we will create a BPEL process which will write (enqueue) a message to a JMS queue using a JMS adapter. The JMS adapter will enqueue the full XML payload to the queue. This sample will use the following WebLogic Server objects. The first two, the Connection Factory and JMS Queue, were created as part of the first blog post in this series, JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g. If you haven't created those objects yet, please see that post for details on how to do so. The Connection Pool will be created as part of this example. Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue 1. Verify Connection Factory and JMS Queue As mentioned above, this example uses a WLS Connection Factory called TestConnectionFactory and a JMS queue TestJMSQueue. As these are prerequisites for this example, let us verify they exist. Log in to the WebLogic Server Administration Console. Select Services > JMS Modules > TestJMSModule You should see the following objects: If not, or if the TestJMSModule is missing, please see the abovementioned article and create these objects before continuing. 2. Create a JMS Adapter Connection Pool in WebLogic Server The BPEL process we are about to create uses a JMS adapter to write to the JMS queue. The JMS adapter is deployed to the WebLogic server and needs to be configured to include a connection pool which references the connection factory associated with the JMS queue. In the WebLogic Server Console Go to Deployments > Next and select (click on) the JmsAdapter Select Configuration > Outbound Connection Pools and expand oracle.tip.adapter.jms.IJmsConnectionFactory. This will display the list of connections configured for this adapter. For example, eis/aqjms/Queue, eis/aqjms/Topic etc. These JNDI names are actually quite confusing. We are expecting to configure a connection pool here, but the names refer to queues and topics. One would expect these to be called *ConnectionPool or *_CF or similar, but to conform to this nomenclature, we will call our entry eis/wls/TestQueue . This JNDI name is also the name we will use later, when creating a BPEL process to access this JMS queue! Select New, check the oracle.tip.adapter.jms.IJmsConnectionFactory check box and Next. Enter JNDI Name: eis/wls/TestQueue for the connection instance, then press Finish. Expand oracle.tip.adapter.jms.IJmsConnectionFactory again and select (click on) eis/wls/TestQueue The ConnectionFactoryLocation must point to the JNDI name of the connection factory associated with the JMS queue you will be writing to. In our example, this is the connection factory called TestConnectionFactory, with the JNDI name jms/TestConnectionFactory.( As a reminder, this connection factory is contained in the JMS Module called TestJMSModule, under Services > Messaging > JMS Modules > TestJMSModule which we verified at the beginning of this document. )Enter jms/TestConnectionFactory  into the Property Value field for Connection Factory Location. After entering it, you must press Return/Enter then Save for the value to be accepted. If your WebLogic server is running in Development mode, you should see the message that the changes have been activated and the deployment plan successfully updated. If not, then you will manually need to activate the changes in the WebLogic server console. Although the changes have been activated, the JmsAdapter needs to be redeployed in order for the changes to become effective. This should be confirmed by the message Remember to update your deployment to reflect the new plan when you are finished with your changes as can be seen in the following screen shot: The next step is to redeploy the JmsAdapter.Navigate back to the Deployments screen, either by selecting it in the left-hand navigation tree or by selecting the “Summary of Deployments” link in the breadcrumbs list at the top of the screen. Then select the checkbox next to JmsAdapter and press the Update button On the Update Application Assistant page, select “Redeploy this application using the following deployment files” and press Finish. After a few seconds you should get the message that the selected deployments were updated. The JMS adapter configuration is complete and it can now be used to access the JMS queue. To summarize: we have created a JMS adapter connection pool connector with the JNDI name jms/TestConnectionFactory. This is the JNDI name to be accessed by a process such as a BPEL process, when using the JMS adapter to access the previously created JMS queue with the JNDI name jms/TestJMSQueue. In the following step, we will set up a BPEL process to use this JMS adapter to write to the JMS queue. 3. Create a BPEL Composite with a JMS Adapter Partner Link This step requires that you have a valid Application Server Connection defined in JDeveloper, pointing to the application server on which you created the JMS Queue and Connection Factory. You can create this connection in JDeveloper under the Application Server Navigator. Give it any name and be sure to test the connection before completing it. This sample will use the connection name jbevans-lx-PS5, as that is the name of the connection pointing to my SOA PS5 installation. When using a JMS adapter from within a BPEL process, there are various configuration options, such as the operation type (consume message, produce message etc.), delivery mode and message type. One of these options is the choice of the format of the JMS message payload. This can be structured around an existing XSD, in which case the full XML element and tags are passed, or it can be opaque, meaning that the payload is sent as-is to the JMS adapter. In the case of an XSD-based message, the payload can simply be copied to the input variable of the JMS adapter. In the case of an opaque message, the JMS adapter’s input variable is of type base64binary. So the payload needs to be converted to base64 binary first. I will go into this in more detail in a later blog entry. This sample will pass a simple message to the adapter, based on the following simple XSD file, which consists of a single string element: stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://www.example.org" targetNamespace="http://www.example.org" elementFormDefault="qualified" <xsd:element name="exampleElement" type="xsd:string"> </xsd:element> </xsd:schema> The following steps are all executed in JDeveloper. The SOA project will be created inside a JDeveloper Application. If you do not already have an application to contain the project, you can create a new one via File > New > General > Generic Application. Give the application any name, for example JMSTests and, when prompted for a project name and type, call the project JmsAdapterWriteWithXsd and select SOA as the project technology type. If you already have an application, continue below. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterWriteSchema. When prompted for the composite type, choose Composite With BPEL Process. When prompted for the BPEL Process, name it JmsAdapterWriteSchema too and choose Synchronous BPEL Process as the template. This will create a composite with a BPEL process and an exposed SOAP service. Double-click the BPEL process to open and begin editing it. You should see a simple BPEL process with a Receive and Reply activity. As we created a default process without an XML schema, the input and output variables are simple strings. Create an XSD File An XSD file is required later to define the message format to be passed to the JMS adapter. In this step, we create a simple XSD file, containing a string variable and add it to the project. First select the xsd item in the left-hand navigation tree to ensure that the XSD file is created under that item. Select File > New > General > XML and choose XML Schema. Call it stringPayload.xsd and when the editor opens, select the Source view. then replace the contents with the contents of the stringPayload.xsd example above and save the file. You should see it under the xsd item in the navigation tree. Create a JMS Adapter Partner Link We will create the JMS adapter as a service at the composite level. If it is not already open, double-click the composite.xml file in the navigator to open it. From the Component Palette, drag a JMS adapter over onto the right-hand swim lane, under External References. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterWrite Oracle Enterprise Messaging Service (OEMS): Oracle Weblogic JMS AppServer Connection: Use an existing application server connection pointing to the WebLogic server on which the above JMS queue and connection factory were created. You can use the “+” button to create a connection directly from the wizard, if you do not already have one. This example uses a connection called jbevans-lx-PS5. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Produce Message Operation Name: Produce_message Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created earlier. JNDI Name: The JNDI name to use for the JMS connection. This is probably the most important step in this exercise and the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) MessagesURL: We will use the XSD file we created earlier, stringPayload.xsd to define the message format for the JMS adapter. Press the magnifying glass icon to search for schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string. Press Next and Finish, which will complete the JMS Adapter configuration. Wire the BPEL Component to the JMS Adapter In this step, we link the BPEL process/component to the JMS adapter. From the composite.xml editor, drag the right-arrow icon from the BPEL process to the JMS adapter’s in-arrow. This completes the steps at the composite level. 4. Complete the BPEL Process Design Invoke the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterWriteSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterWrite partner link under one of the two swim lanes. We want it in the right-hand swim lane. If JDeveloper displays it in the left-hand lane, right-click it and choose Display > Move To Opposite Swim Lane. An Invoke activity is required in order to invoke the JMS adapter. Drag an Invoke activity between the Receive and Reply activities. Drag the right-hand arrow from the Invoke activity to the JMS adapter partner link. This will open the Invoke editor. The correct default values are entered automatically and are fine for our purposes. We only need to define the input variable to use for the JMS adapter. By pressing the green “+” symbol, a variable of the correct type can be auto-generated, for example with the name Invoke1_Produce_Message_InputVariable. Press OK after creating the variable. ( For some reason, while I was testing this, the JMS Adapter moved back to the left-hand swim lane again after this step. There is no harm in leaving it there, but I find it easier to follow if it is in the right-hand lane, because I kind-of think of the message coming in on the left and being routed through the right. But you can follow your personal preference here.) Assign Variables Drag an Assign activity between the Receive and Invoke activities. We will simply copy the input variable to the JMS adapter and, for completion, so the process has an output to print, again to the process’s output variable. Double-click the Assign activity and create two Copy rules: for the first, drag Variables > inputVariable > payload > client:process > client:input_string to Invoke1_Produce_Message_InputVariable > body > ns2:exampleElement for the second, drag the same input variable to outputVariable > payload > client:processResponse > client:result This will create two copy rules, similar to the following: Press OK. This completes the BPEL and Composite design. 5. Compile and Deploy the Composite We won’t go into too much detail on how to compile and deploy. In JDeveloper, compile the process by pressing the Make or Rebuild icons or by right-clicking the project name in the navigator and selecting Make... or Rebuild... If the compilation is successful, deploy it to the SOA server connection defined earlier. (Right-click the project name in the navigator, select Deploy to Application Server, choose the application server connection, choose the partition on the server (usually default) and press Finish. You should see the message ---- Deployment finished. ---- in the Deployment frame, if the deployment was successful. 6. Test the Composite This is the exciting part. Open two tabs in your browser and log in to the WebLogic Administration Console in one tab and the Enterprise Manager 11g Fusion Middleware Control (EM) for your SOA installation in the other. We will use the Console to monitor the messages being written to the queue and the EM to execute the composite. In the Console, go to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. Note the number of messages under Messages Current. In the EM, go to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterWriteSchema [1.0], then press the Test button. Under Input Arguments, enter any string into the text input field for the payload, for example Test Message then press Test Web Service. If the instance is successful you should see the same text in the Response message, “Test Message”. In the Console, refresh the Monitoring screen to confirm a new message has been written to the queue. Check the checkbox and press Show Messages. Click on the newest message and view its contents. They should include the full XML of the entered payload. 7. Troubleshooting If you get an exception similar to the following at runtime ... BINDING.JCA-12510 JCA Resource Adapter location error. Unable to locate the JCA Resource Adapter via .jca binding file element The JCA Binding Component is unable to startup the Resource Adapter specified in the element: location='eis/wls/QueueTest'. The reason for this is most likely that either 1) the Resource Adapters RAR file has not been deployed successfully to the WebLogic Application server or 2) the '' element in weblogic-ra.xml has not been set to eis/wls/QueueTest. In the last case you will have to add a new WebLogic JCA connection factory (deploy a RAR). Please correct this and then restart the Application Server at oracle.integration.platform.blocks.adapter.fw.AdapterBindingException. createJndiLookupException(AdapterBindingException.java:130) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.createJCAConnectionFactory (JCAConnectionManager.java:1387) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.newPoolObject (JCAConnectionManager.java:1285) ... then this is very likely due to an incorrect JNDI name entered for the JMS Connection in the JMS Adapter Wizard. Recheck those steps. The error message prints the name of the JNDI name used. In this example, it was incorrectly entered as eis/wls/QueueTest instead of eis/wls/TestQueue. This concludes this example. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • When do I use Apache Kafka, Azure Service Bus, vs Azure Queues?

    - by makerofthings7
    I'm trying to understand the situations I'd use Apache Kafka, Azure Service Bus, or Azure Queues for high scale message processing. Which is better for standard Pub Sub situations? Where multiple clients get a copy of the same message? Which is better for low latency Pub sub and no durability? Which is better for "cooperating producer" and "competing consumer"? (what does this mean?) I see a bit of overlap in function between Kafka, Service Bus, Azure Queues

    Read the article

  • sftp Bad message - (badly formatted packet or protocol incompatibility)

    - by culter
    I have two servers connected through SFTP. When I'm trying to upload file DONATE_SPLATNOSTSFRB-1503_20120315.xls.gpg via WinSCP, it works fine, but when I change file name to DONATE_SPLATNOSTSFRB-1503_20120315.gpg it sometimes upload to server and sometimes not. When It's uploaded, I have problems to delete it. I get this error message: Bad message - (badly formatted packet or protocol incompatibility) Error code: 5 Error message from server: Bad Message Request code: 13 Others files works fine e.g.: DONATE_PREDSFRB-0212_20120315.gpg Thank you.

    Read the article

  • exchange user receive Undeliverable: form postmaster after every sended message

    - by Alexander Pavluchenko
    this happens after users mailbox moved from one exchange to other (in one organization, but differend domains) details: From: postmaster Sent: Saturday, April 03, 2010 8:43 AM To: USER1 Subject: Undeliverable: subject of message Delivery has failed to these recipients or distribution lists: IMCEAex-_O=DOMAIN_OU=First+20Administrative+20Group_cn=Recipients_cn=USER1@domain A problem occurred during the delivery of this message. Microsoft Exchange will not try to redeliver this message for you. Please try resending this message later, or provide the following diagnostic text to your system administrator.

    Read the article

  • Message From David Callaghan: Be The Best We Can Be

    - by swalker
    In this new message, David Callaghan shares his observations on taking the lead of EMEA Alliances & Channels and outlines his personal mantra and priorities for FY13. Please watch this video to hear David's perspective on the most significant evolution of Alliances & Channels, and how we can be successful by making the most of the unique opportunities of Oracle on Oracle together.

    Read the article

  • How To - Securing a JAX-WS with OWSM Message Protection Policy in JDeveloper - 11g

    - by Prakash Yamuna
    As promised in this post, here is a How-To that describes how to secure a simple HelloWorld JAX-WS with OWSM message protection policy and test it with SOAP UI. The How-To reuses the picture I posted earlier about the relationship and interplay b/w Keystore, Credential store, jps-config.xml ,etc. One of the other more frequent requests I hear from folks within Oracle and customers is how to test OWSM with SOAP UI. SOAP UI in general works very well as testing tool for web services secure with wss10 policies.

    Read the article

  • Ubuntu login failed to set mode on [CRTC:10] message

    - by polyglot0727
    I recently installed Windows Server 2003 and Ubuntu 12.10 side by side. Both worked ok for the first couple of boots. I can boot to Server, but am unable to boot to Ubuntu. I receive this message. ubuntu login: [ 18.684356 ] [drm:drm_crtc_helper_set_config] ERROR failed to set mode on [CRTC:10] [ 18.840839 [drm:drm_crtc_helper_set_config] ERROR failed to set mode on [CRTC:10]. Any idea what the issue is?

    Read the article

  • Error Message when starting Update: Failed to load the package list

    - by George
    Message says: Failed to load the package list This is a serious problem. Try again later. If this problem appears again, please report an error to the developers. Click details, which says: E:Type 'http://ppa.launchpad.net/madman2k/ubuntu' is not known on line 61 in source list /etc/apt/sources.list Tried this solution: sudo rm /var/lib/apt/lists/* -vf sudo apt-get update However, when entering the first command, it hits back an error: rm: cannot remove `/var/lib/apt/lists': Is a directory

    Read the article

  • Running crysis 2 on ubuntu gives me an error message

    - by ShajD
    so i recently installed ubuntu alongside windows 7 and i installed crysis 2 with wine. crysis 2 works fine when i run windows, however when i run it using wine in ubuntu cryengine gives me a message saying, "Unsupported video card detected! Continuing to run migth lead to unexpected results or crashes....." i've got two video cards ones an intel and the other's a nvidia. i typed lspci into the terminal and my nvidia card was listed under video controller as well

    Read the article

  • The boot selection failed because a required device is inaccessible 0xc000000e

    - by bbodenmiller
    A family member of mine recently went on vacation and turned off their computer, something they normally do not do, upon returning home it would not turn on and now returns the error message below. Generally friends and family come to me for help with computers and I have no problem, however this time I am a bit stumped. Any suggestions would be greatly appreciated. As you can see the error message is: Status: 0xc000000e Info: The best selection failed because a required device is inaccessible. Before going to this error message it briefly flashes the Windows loading screen. I have been able to confirm through the Windows RE Command Line and the dir command that the C: drive is accessible and likely is just suffering a bootup issue. I have tried: Launching the repair process discussed in the error message three times however each time it requires a restart and then returns to the same error message. Changing the boot order to be hard drive first Getting into safe mode; F8 just results in the same error message before I can get to the menu to select safe mode I have checked to make sure the BCD (bcdedit, Boot Configuration Data) is still intact as per https://www.symantec.com/business/support/index?page=content&id=TECH160475 I plan to try (but would like additional comments on): sfc /scannow; requires a restart and thus will likely result in the error message again A memory scan Bootrec as per http://support.microsoft.com/kb/927392#method1 Swapping IDE cables/ports Resetting the BIOS I noticed others with similar issues around the web are dual-booting however this machine is not setup in a dual-boot environment. Additionally at one point this error message supposedly showed up before I started working on the computer: The instruction at 0xfbe2584d referenced memory at 0x00000008. The memory could not be read. As previously stated any additional suggestions or words of advice would be greatly apprecaited.

    Read the article

  • Windows Scheduler OR SQL Server Job for sending out digest e-mails

    - by wgpubs
    Will be sending out e-mails from an application on a scheduled basis. I have an EmailController in my ASP.NET MVC application with action methods, one for each kind of notification/e-mail, that will need to be called at different times during the week. Question: Is Windows Scheduler (running on a Server 2008 box) any better or worse than scheduling this via a SQL Server job? And why? Thanks

    Read the article

  • ruby-gstreamer doesn't send EOS message

    - by Cheba
    I've managed to make it play sound but it never gets EOS message. And thus script never exits. require 'gst' main_loop = GLib::MainLoop.new pipeline = Gst::Pipeline.new "audio-player" source = Gst::ElementFactory.make "filesrc", "file-source" source.location = "/usr/share/sounds/gnome/default/alerts/bark.ogg" decoder = Gst::ElementFactory.make "decodebin", "decoder" conv = Gst::ElementFactory.make "audioconvert", "converter" sink = Gst::ElementFactory.make "alsasink", "output" pipeline.add source, decoder, conv, sink source >> decoder conv >> sink decoder.signal_connect "pad-added" do |element, pad, data| pad >> conv['sink'] end pipeline.bus.add_watch do |bus, message| puts "Message: #{message.inspect}" case message.type when Gst::Message::Type::ERROR puts message.structure["debug"] main_loop.quit when Gst::Message::Type::EOS puts 'End of stream' main_loop.quit end end pipeline.play begin puts 'Running main loop' main_loop.run ensure puts 'Shutting down main loop' pipeline.stop end

    Read the article

  • WebSphere MQ/MQSeries - Possible to send a message to multiple queues with single call?

    - by Jeffrey White
    I'm queuing messages to a WebSphere MQ queue (NB: A point-to-point queue -- not a topic) using a stored procedure in my Oracle database. Is there a way to publish each message to multiple queues with a single call? What I would like is to find a solution that would incur zero additional latency on my database compared to sending the message to a single queue. Solutions that involve changing my WebSphere MQ settings are certainly welcome! What I had in mind was somehow creating a "clone" queue that got all the same messages as the original one, but I've been unable to locate anything like this in the documentation. Thanks, Jeff

    Read the article

  • Help with Silverlight Sockets and Message delivery

    - by pixel3cs
    There are 4 months since I stopped developing my Silverlight Multiplayer Chess game. The problem was a bug wich I couldn't reproduce. Sice I got some free time this week I managed to discover the problem and I am now able to reproduce the bug. It seems that if I send 10 messages from client, one after another, with no delay between them, just like in the below example // when I press Enter, the client will 10 messages with no delay between them private void textBox_KeyDown(object sender, KeyEventArgs e) { if (e.Key == Key.Enter && textBox.Text.Length > 0) { for (int i = 0; i < 10; i++) { MessageBuilder mb = new MessageBuilder(); mb.Writer.Write((byte)GameCommands.NewChatMessageInTable); mb.Writer.Write(string.Format("{0}{2}: {1}", ClientVars.PlayerNickname, textBox.Text, i)); SendChatMessageEvent(mb.GetMessage()); //System.Threading.Thread.Sleep(100); } textBox.Text = string.Empty; } } // the method used by client to send a message to server public void SendData(Message message) { if (socket.Connected) { SocketAsyncEventArgs myMsg = new SocketAsyncEventArgs(); myMsg.RemoteEndPoint = socket.RemoteEndPoint; byte[] buffer = message.Buffer; myMsg.SetBuffer(buffer, 0, buffer.Length); socket.SendAsync(myMsg); } else { string err = "Server does not respond. You are disconnected."; socket.Close(); uiContext.Post(this.uiClient.ProcessOnErrorData, err); } } // the method used by server to receive data from client private void OnDataReceived(IAsyncResult async) { ClientSocketPacket client = async.AsyncState as ClientSocketPacket; int count = 0; try { if (client.Socket.Connected) count = client.Socket.EndReceive(async); // THE PROBLEM IS HERE // IF SERVER WAS RECEIVE ALL MESSAGES SEPARATELY, ONE BY ONE, THE COUNT // WAS ALWAYS 15, BUT BECAUSE THE SERVER RECEIVE 3 MESSAGES IN 1, THE COUNT // IS SOMETIME 45 } catch { HandleException(client); } client.MessageStream.Write(client.Buffer, 0, count); Message message; while (client.MessageStream.Read(out message)) { message.Tag = client; ThreadPool.QueueUserWorkItem(new WaitCallback(this.processingThreadEvent.ServerGotData), message); totalReceivedBytes += message.Buffer.Length; } try { if (client.Socket.Connected) client.Socket.BeginReceive(client.Buffer, 0, client.Buffer.Length, 0, new AsyncCallback(OnDataReceived), client); } catch { HandleException(client); } } there are sent only 3 big messages, and every big message contain 3 or 4 small messages. This is not the behavior I want. If I put a 100 milliseconds delay between message delivery, everything is work fine, but in a real world scenario users can send messages to server even at 1 millisecond between them. Are there any settings to be done in order to make the client send only one message at a time, or Even if I receive 3 messages in 1, are they full messages all the time (I dont't want to receive 2.5 messages in one big message) ? because if they are, I can read them and treat this new situation

    Read the article

  • Message Handlers and the WeakReference issue

    - by user1058647
    The following message Handler works fine receiving messages from my service... private Handler handler = new Handler() { public void handleMessage(Message message) { Object path = message.obj; if (message.arg1 == 5 && path != null) //5 means its a single mapleg to plot on the map { String myString = (String) message.obj; Gson gson = new Gson(); MapPlot mapleg = gson.fromJson(myString, MapPlot.class); myMapView.getOverlays().add(new DirectionPathOverlay(mapleg.fromPoint, mapleg.toPoint)); mc.animateTo(mapleg.toPoint); } else { if (message.arg1 == RESULT_OK && path != null) { Toast.makeText(PSActivity.this, "Service Started" + path.toString(), Toast.LENGTH_LONG).show(); } else { Toast.makeText(PSActivity.this,"Service error" + String.valueOf(message.arg1), Toast.LENGTH_LONG).show(); } } }; }; However, even though it tests out alright in the AVD (I'm feeding it a large KML file via DDMS) the "object path = message.obj;" line has a WARNING saying "this Handler class should be static else leaks might occur". But if I say "static Handler handler = new Handler()" it won't compile complaining that I "cannot make a static reference to a non-static field myMapView. If I can't make such references, I can't do anything useful. This led me into several hours of googling around on this issue and learning more about weakReferences than I ever wanted to know. The often found reccomendation I find is that I should replace... private Handler handler = new Handler() with static class handler extends Handler { private final WeakReference<PSActivity> mTarget; handler(PSActivity target) { mTarget = new WeakReference<PSActivity>(target); } But this won't compile still complaining that I can't make a static reference to a non-dtatic field. So, my question a week or to ago was "how can I write a message handler for android so my service can send data to my activity. Even though I have working code, the question still stands with the suffix "without leaking memory". Thanks, Gary

    Read the article

  • Is ZeroMQ a good choice to make a Python app and a C# managed assembly work together?

    - by Alex Bausk
    I have a task that involves talking to a .NET-based API (namely AutoCAD) to retrieve data, send commands, and react to events. I want to separate the API operations and the proper program logic (largely already implemented in Python) by using natural tools for both: a C# DLL for the former and a Python app for the latter. To connect these two pieces, I began exchanging JSON in ZeroMQ messages. I'm at early development stages but having recently discovered that ZeroMQ does not guarantee message delivery/order, I have reservations about whether this is a feasible way to go. Right now my app is a very basic REQ/REP pair and I plan to handle reacting to events and executing different commands by adding some sort of 'recipient-function' field to my message format. The reason that I want to use ZMQ is that I might be able to scale the software into a larger, multi-user, distributed solution sometime. I am a lay programmer so I would ask for your advice about this architecture. Should I just go ahead with it and plan to deal with message reliability/ordering when problems appear? Should I consider developing some kind of a REST wrapper around ZMQ?

    Read the article

  • Thunderbird: moving email from local Junk folder to IMAP folder yields "Message contains invalid header"

    - by Peltier
    Whenever I try to move an email from a local Junk folder to an IMAP folder in Thunderbird, I get the following error message: The current command did not succeed. The mail server responded: Message contains invalid header If Thunderbird's Junk folder is an IMAP folder on the server, then after Thunderbird has moved messages to that folder, I can successfully move messages from Junk back into to some other IMAP folder. However, if the Junk folder is not on the server, then moving a message from the local Junk folder to an IMAP folder yields the aforementioned error. The only interesting thing I've found about this error is "Message contains invalid header" from the MozillaZine Knowledge Base. That article officially is about importing folders from another email client, and does not mention the Junk filter as another possible cause. However the proposed solution is not very helpful since it requires manual editing of the message box files. Any better ideas? EDIT: make sure you read the comments before answering the question.