Search Results

Search found 560 results on 23 pages for 'pascal fc'.

Page 10/23 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • Bash arrays and case statements - review my script

    - by Felipe Alvarez
    #!/bin/bash # Change the environment in which you are currently working. # Actually, it calls the relevant 'lettus.sh' script if [ "${BASH_SOURCE[0]}" == "$0" ]; then echo "Try running this as \". chenv $1\"" exit 0 fi usage(){ echo "Usage: . ${PROG} -- Shows a list of user-selectable environments." echo " . ${PROG} [env] -- Select environment." echo " . ${PROG} -h -- Shows this usage screen." return } showEnv(){ # check if index0 exists, assume we have at least the first (zeroth) element #if [ -z "${envList}" ]; then if [ -z "${envList[0]}" ]; then echo "array \$envList is empty! " >&2 return 1 fi # Show all elements in array (0 -> n-1) for i in $(seq 0 $((${#envList[@]} - 1))); do echo ${envList[$i]} done return } setEnv(){ if [ -z "$1" ]; then usage; return fi case $1 in cold) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_cold.sh;; coles) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_coles.sh;; fc) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_fc.sh;; fcrm) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_fcrm.sh;; stable) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_stable.sh;; tip) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_tip.sh;; uat) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_uat.sh;; wellmdc) FILE_TO_SOURCE=/u2/tip/conf/ctrl/lettus_wellmdc.sh;; *) usage; return;; esac if $IS_SOURCED; then echo "Environment \"$1\" selected." echo "Now sourcing file \"$FILE_TO_SOURCE\"..." . ${FILE_TO_SOURCE} return else return 1 fi } main(){ if [ -z "$1" ]; then showEnv; return fi case $1 in -h) usage;; *) setEnv $1;; esac return } PROG="chenv" # create array of user-selectable environments envList=( cold coles fc fcrm stable tip uat wellmdc ) main "$@" return If I could, I'd like to get some feedback on a better way to accomplish any of the following: run through the case statement make script trivally simple to maintain/upgrade/update

    Read the article

  • Network is not working anymore - Ubuntu 12.04

    - by Jonathan
    Network is not working anymore - Ubuntu 12.04 Hello, I have a problem with my network connection. I have been using the same laptop with Ubuntu and the same connection for more than a year, and suddenly yesterday the connection stopped working (both wireless and wired). I've tested with another computer and the connection is fine (both wireless and wired). I've been reading similar posts but I haven't found a solution yet. I tried a few commands that I'm posting here (my system is in spanish, so I have traslated it to english, maybe the terms are not accurate): grep -i eth /var/log/syslog | tail Jun 3 18:45:40 vanesa-pc NetworkManager[3584]: (eth0): now managed Jun 3 18:45:40 vanesa-pc NetworkManager[3584]: (eth0): device state change: unmanaged - unavailable (reason 'managed') [10 20 2] Jun 3 18:45:40 vanesa-pc NetworkManager[3584]: (eth0): bringing up device. Jun 3 18:45:40 vanesa-pc NetworkManager[3584]: (eth0): preparing device. Jun 3 18:45:40 vanesa-pc kernel: [ 7351.845743] forcedeth 0000:00:0a.0: irq 41 for MSI/MSI-X Jun 3 18:45:40 vanesa-pc kernel: [ 7351.845984] forcedeth 0000:00:0a.0: eth0: no link during initialization Jun 3 18:45:40 vanesa-pc kernel: [ 7351.847103] ADDRCONF(NETDEV_UP): eth0: link is not ready Jun 3 18:45:40 vanesa-pc NetworkManager[3584]: (eth0): deactivating device (reason 'managed') [2] Jun 3 18:45:40 vanesa-pc NetworkManager[3584]: Added default wired connection 'Wired connection 1' for /sys/devices/pci0000:00/0000:00:0a.0/net/eth0 Jun 3 18:45:40 vanesa-pc kernel: [ 7351.848817] ADDRCONF(NETDEV_UP): eth0: link is not ready ifconfig -a eth0 Link encap:Ethernet addressHW 00:1b:24:fc:a8:d1 ACTIVE BROADCAST MULTICAST MTU:1500 Metric:1 Packages RX:0 errors:16 lost:0 overruns:0 frame:16 Packages TX:123 errors:0 lost:0 overruns:0 carrier:0 colissions:0 length.tailTX:1000 Bytes RX:0 (0.0 B) TX bytes:26335 (26.3 KB) Interruption:41 Base address: 0x2000 lo Link encap:Local loop Inet address:127.0.0.1 Mask:255.0.0.0 Inet6 address: ::1/128 Scope:Host ACTIVE LOOP WORKING MTU:16436 Metrics:1 Packages RX:1550 errors:0 lost:0 overruns:0 frame:0 Packages TX:1550 errors:0 lost:0 overruns:0 carrier:0 colissions:0 long.tailTX:0 Bytes RX:125312 (125.3 KB) TX bytes:125312 (125.3 KB) iwconfig lo no wireless extensions. eth0 no wireless extensions. sudo lshw -C network *-network description: Ethernet interface product: MCP67 Ethernet manufacturer: NVIDIA Corporation Physical id: a bus information: pci@0000:00:0a.0 logical name: eth0 version: a2 series: 00:1b:24:fc:a8:d1 capacity: 100Mbit/s width: 32 bits clock: 66MHz capacities: pm msi ht bus_master cap_list ethernet physical mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=forcedeth driverversion=0.64 latency=0 link=no maxlatency=20 mingnt=1 multicast=yes port=MII resources: irq:41 memoria:f6288000-f6288fff ioport:30f8(size=8) memoria:f6289c00-f6289cff memoria:f6289800-f628980f lsmod Module Size Used by usbhid 41906 0 hid 77367 1 usbhid rfcomm 38139 0 parport_pc 32114 0 ppdev 12849 0 bnep 17830 2 bluetooth 158438 10 rfcomm,bnep binfmt_misc 17292 1 joydev 17393 0 hp_wmi 13652 0 sparse_keymap 13658 1 hp_wmi nouveau 708198 3 ttm 65344 1 nouveau drm_kms_helper 45466 1 nouveau drm 197692 5 nouveau,ttm,drm_kms_helper i2c_algo_bit 13199 1 nouveau psmouse 87213 0 mxm_wmi 12859 1 nouveau serio_raw 13027 0 k8temp 12905 0 i2c_nforce2 12906 0 wmi 18744 2 hp_wmi,mxm_wmi video 19068 1 nouveau mac_hid 13077 0 lp 17455 0 parport 40930 3 parport_pc,ppdev,lp forcedeth 58096 0 Let me know if I can give you more information. Thank you very much in advance, Jonathan

    Read the article

  • Oracle's Sun ZFS Storage Appliances and Oracle VM

    - by uwes
    Oracle's Sun ZFS Storage Appliance Is the Optimal Platform for Deploying Consolidated Applications in an Oracle Virtual Machine (OVM) Environment Unsurpassed Integration - Oracle VM and Storage Engineering teams provide seamless integration points and an Oracle VM Connect Plug-In for Sun ZFS Storage Appliance in FC, NFS, and iSCSI Environments.  And Sun ZFS Storage is engineered and tested to work with Oracle VM agility features including Live (VM) Migration and oracle RAC Live Migration. More information could befound under the following links: ZFS Storage Appliance Server Virtualization Oracle.com page ZFS Storage Appliance Oracle.com page ZFS Storage Appliance Oracle Technical Network.com page Software download support.oracle.com page

    Read the article

  • Delphi Prism 2011 arrive le mois prochain, la plateforme pour développer des applications .NET en De

    Delphi Prism 2011 arriverait le mois prochain La plateforme pour développer des applications .NET en Delphi sera compatible avec Visual Studio 2010 Delphi Prism est une plateforme imaginée par Embarcadero qui permet de développer des applications .NET en Delphi. Il s'agit donc, en résumé, d'un compilateur Delphi (le langage Pascal Objet adapté pour les composants et le développement RAD) qui génère des applications utilisant la plateforme Microsoft .NET. Son environnement de développement était jusqu'ici Visual Studio 2008 Shell. Avec l'arrivée le mois prochain de Delphi Prism 2011, la plateforme pourra à présent être utilisée avec

    Read the article

  • Das T5-4 TPC-H Ergebnis naeher betrachtet

    - by Stefan Hinker
    Inzwischen haben vermutlich viele das neue TPC-H Ergebnis der SPARC T5-4 gesehen, das am 7. Juni bei der TPC eingereicht wurde.  Die wesentlichen Punkte dieses Benchmarks wurden wie gewohnt bereits von unserer Benchmark-Truppe auf  "BestPerf" zusammengefasst.  Es gibt aber noch einiges mehr, das eine naehere Betrachtung lohnt. Skalierbarkeit Das TPC raet von einem Vergleich von TPC-H Ergebnissen in unterschiedlichen Groessenklassen ab.  Aber auch innerhalb der 3000GB-Klasse ist es interessant: SPARC T4-4 mit 4 CPUs (32 Cores mit 3.0 GHz) liefert 205,792 QphH. SPARC T5-4 mit 4 CPUs (64 Cores mit 3.6 GHz) liefert 409,721 QphH. Das heisst, es fehlen lediglich 1863 QphH oder 0.45% zu 100% Skalierbarkeit, wenn man davon ausgeht, dass die doppelte Anzahl Kerne das doppelte Ergebnis liefern sollte.  Etwas anspruchsvoller, koennte man natuerlich auch einen Faktor von 2.4 erwarten, wenn man die hoehere Taktrate mit beruecksichtigt.  Das wuerde die Latte auf 493901 QphH legen.  Dann waere die SPARC T5-4 bei 83%.  Damit stellt sich die Frage: Was hat hier nicht skaliert?  Vermutlich der Plattenspeicher!  Auch hier lohnt sich eine naehere Betrachtung: Plattenspeicher Im Bericht auf BestPerf und auch im Full Disclosure Report der TPC stehen einige interessante Details zum Plattenspeicher und der Konfiguration.   In der Konfiguration der SPARC T4-4 wurden 12 2540-M2 Arrays verwendet, die jeweils ca. 1.5 GB/s Durchsatz liefert, insgesamt also eta 18 GB/s.  Dabei waren die Arrays offensichtlich mit jeweils 2 Kabeln pro Array direkt an die 24 8GBit FC-Ports des Servers angeschlossen.  Mit den 2x 8GBit Ports pro Array koennte man so ein theoretisches Maximum von 2GB/s erreichen.  Tatsaechlich wurden 1.5GB/s geliefert, was so ziemlich dem realistischen Maximum entsprechen duerfte. Fuer den Lauf mit der SPARC T5-4 wurden doppelt so viele Platten verwendet.  Dafuer wurden die 2540-M2 Arrays mit je einem zusaetzlichen Plattentray erweitert.  Mit dieser Konfiguration wurde dann (laut BestPerf) ein Maximaldurchsatz von 33 GB/s erreicht - nicht ganz das doppelte des SPARC T4-4 Laufs.  Um tatsaechlich den doppelten Durchsatz (36 GB/s) zu liefern, haette jedes der 12 Arrays 3 GB/s ueber seine 4 8GBit Ports liefern muessen.  Im FDR stehen nur 12 dual-port FC HBAs, was die Verwendung der Brocade FC Switches erklaert: Es wurden alle 4 8GBit ports jedes Arrays an die Switches angeschlossen, die die Datenstroeme dann in die 24 16GBit HBA ports des Servers buendelten.  Das theoretische Maximum jedes Storage-Arrays waere nun 4 GB/s.  Wenn man jedoch den Protokoll- und "Realitaets"-Overhead mit einrechnet, sind die tatsaechlich gelieferten 2.75 GB/s gar nicht schlecht.  Mit diesen Zahlen im Hinterkopf ist die Verdopplung des SPARC T4-4 Ergebnisses eine gute Leistung - und gleichzeitig eine gute Erklaerung, warum nicht bis zum 2.4-fachen skaliert wurde. Nebenbei bemerkt: Weder die SPARC T4-4 noch die SPARC T5-4 hatten in der gemessenen Konfiguration irgendwelche Flash-Devices. Mitbewerb Seit die T4 Systeme auf dem Markt sind, bemuehen sich unsere Mitbewerber redlich darum, ueberall den Eindruck zu hinterlassen, die Leistung des SPARC CPU-Kerns waere weiterhin mangelhaft.  Auch scheinen sie ueberzeugt zu sein, dass (ueber)grosse Caches und hohe Taktraten die einzigen Schluessel zu echter Server Performance seien.  Wenn ich mir nun jedoch die oeffentlichen TPC-H Ergebnisse ansehe, sehe ich dies: TPC-H @3000GB, Non-Clustered Systems System QphH SPARC T5-4 3.6 GHz SPARC T5 4/64 – 2048 GB 409,721.8 SPARC T4-4 3.0 GHz SPARC T4 4/32 – 1024 GB 205,792.0 IBM Power 780 4.1 GHz POWER7 8/32 – 1024 GB 192,001.1 HP ProLiant DL980 G7 2.27 GHz Intel Xeon X7560 8/64 – 512 GB 162,601.7 Kurz zusammengefasst: Mit 32 Kernen (mit 3 GHz und 4MB L3 Cache), liefert die SPARC T4-4 mehr QphH@3000GB ab als IBM mit ihrer 32 Kern Power7 (bei 4.1 GHz und 32MB L3 Cache) und auch mehr als HP mit einem 64 Kern Intel Xeon System (2.27 GHz und 24MB L3 Cache).  Ich frage mich, wo genau SPARC hier mangelhaft ist? Nun koennte man natuerlich argumentieren, dass beide Ergebnisse nicht gerade neu sind.  Nun, in Ermangelung neuerer Ergebnisse kann man ja mal ein wenig spekulieren: IBMs aktueller Performance Report listet die o.g. IBM Power 780 mit einem rPerf Wert von 425.5.  Ein passendes Nachfolgesystem mit Power7+ CPUs waere die Power 780+ mit 64 Kernen, verfuegbar mit 3.72 GHz.  Sie wird mit einem rPerf Wert von  690.1 angegeben, also 1.62x mehr.  Wenn man also annimmt, dass Plattenspeicher nicht der limitierende Faktor ist (IBM hat mit 177 SSDs getestet, sie duerfen das gerne auf 400 erhoehen) und IBMs eigene Leistungsabschaetzung zugrunde legt, darf man ein theoretisches Ergebnis von 311398 QphH@3000GB erwarten.  Das waere dann allerdings immer noch weit von dem Ergebnis der SPARC T5-4 entfernt, und gerade in der von IBM so geschaetzen "per core" Metric noch weniger vorteilhaft. In der x86-Welt sieht es nicht besser aus.  Leider gibt es von Intel keine so praktischen rPerf-Tabellen.  Daher muss ich hier fuer eine Schaetzung auf SPECint_rate2006 zurueckgreifen.  (Ich bin kein grosser Fan von solchen Kreuz- und Querschaetzungen.  Insb. SPECcpu ist nicht besonders geeignet, um Datenbank-Leistung abzuschaetzen, da fast kein IO im Spiel ist.)  Das o.g. HP System wird bei SPEC mit 1580 CINT2006_rate gelistet.  Das bis einschl. 2013-06-14 beste Resultat fuer den neuen Intel Xeon E7-4870 mit 8 CPUs ist 2180 CINT2006_rate.  Das ist immerhin 1.38x besser.  (Wenn man nur die Taktrate beruecksichtigen wuerde, waere man bei 1.32x.)  Hier weiter zu rechnen, ist muessig, aber fuer die ungeduldigen Leser hier eine kleine tabellarische Zusammenfassung: TPC-H @3000GB Performance Spekulationen System QphH* Verbesserung gegenueber der frueheren Generation SPARC T4-4 32 cores SPARC T4 205,792 2x SPARC T5-464 cores SPARC T5 409,721 IBM Power 780 32 cores Power7 192,001 1.62x IBM Power 780+ 64 cores Power7+  311,398* HP ProLiant DL980 G764 cores Intel Xeon X7560 162,601 1.38x HP ProLiant DL980 G780 cores Intel Xeon E7-4870    224,348* * Keine echten Resultate  - spekulative Werte auf der Grundlage von rPerf (Power7+) oder SPECint_rate2006 (HP) Natuerlich sind IBM oder HP herzlich eingeladen, diese Werte zu widerlegen.  Aber stand heute warte ich noch auf aktuelle Benchmark Veroffentlichungen in diesem Datensegment. Was koennen wir also zusammenfassen? Es gibt einige Hinweise, dass der Plattenspeicher der begrenzende Faktor war, der die SPARC T5-4 daran hinderte, auf jenseits von 2x zu skalieren Der Mythos, dass SPARC Kerne keine Leistung bringen, ist genau das - ein Mythos.  Wie sieht es umgekehrt eigentlich mit einem TPC-H Ergebnis fuer die Power7+ aus? Cache ist nicht der magische Performance-Schalter, fuer den ihn manche Leute offenbar halten. Ein System, eine CPU-Architektur und ein Betriebsystem jenseits einer gewissen Grenze zu skalieren ist schwer.  In der x86-Welt scheint es noch ein wenig schwerer zu sein. Was fehlt?  Nun, das Thema Preis/Leistung ueberlasse ich gerne den Verkaeufern ;-) Und zu guter Letzt: Nein, ich habe mich nicht ins Marketing versetzen lassen.  Aber manchmal kann ich mich einfach nicht zurueckhalten... Disclosure Statements The views expressed on this blog are my own and do not necessarily reflect the views of Oracle. TPC-H, QphH, $/QphH are trademarks of Transaction Processing Performance Council (TPC). For more information, see www.tpc.org, results as of 6/7/13. Prices are in USD. SPARC T5-4 409,721.8 QphH@3000GB, $3.94/QphH@3000GB, available 9/24/13, 4 processors, 64 cores, 512 threads; SPARC T4-4 205,792.0 QphH@3000GB, $4.10/QphH@3000GB, available 5/31/12, 4 processors, 32 cores, 256 threads; IBM Power 780 QphH@3000GB, 192,001.1 QphH@3000GB, $6.37/QphH@3000GB, available 11/30/11, 8 processors, 32 cores, 128 threads; HP ProLiant DL980 G7 162,601.7 QphH@3000GB, $2.68/QphH@3000GB available 10/13/10, 8 processors, 64 cores, 128 threads. SPEC and the benchmark names SPECfp and SPECint are registered trademarks of the Standard Performance Evaluation Corporation. Results as of June 18, 2013 from www.spec.org. HP ProLiant DL980 G7 (2.27 GHz, Intel Xeon X7560): 1580 SPECint_rate2006; HP ProLiant DL980 G7 (2.4 GHz, Intel Xeon E7-4870): 2180 SPECint_rate2006,

    Read the article

  • Can not connect to wireless on 12.04 with Intel WiFi Link 5100

    - by WiData
    I am having problem in connecting to wifi. I have dual boot (Windows 7 and Ubuntu 12.04) on my Dell Studio 15. I upgraded to 12.04 quite some time ago (at least one month) from 11.10. Everything was working fine till yesterday. Since yesterday I can see the list of available Wifi connection but does not connect to any or if connects (after hours of trying) then disconnects after few minutes. My wifi interface is Intel WiFi Link 5100 AGN. However the problem is on both Windows and Ubuntu. Here are outputs of some commands which may be useful for those interested in helping: ~$ ifconfig eth0 Link encap:Ethernet HWaddr 00:22:19:fa:65:bb UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:17 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:794 errors:0 dropped:0 overruns:0 frame:0 TX packets:794 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:56280 (56.2 KB) TX bytes:56280 (56.2 KB) wlan0 Link encap:Ethernet HWaddr 00:22:fb:d2:fc:ce UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:239 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:53603 (53.6 KB) Here is the output for the command sudo lshw -C network *-network description: Wireless interface product: WiFi Link 5100 vendor: Intel Corporation physical id: 0 bus info: pci@0000:04:00.0 logical name: wlan0 version: 00 serial: 00:22:fb:d2:fc:ce width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlwifi driverversion=3.2.0-48-generic-pae firmware=8.83.5.1 build 33692 latency=0 link=no multicast=yes wireless=IEEE 802.11abgn resources: irq:47 memory:f8000000-f8001fff My kernel version is kernel version 3.2.0-48-generic-pae I also checked this post which was helpful. But I am not sure if what is the exact problem. Any suggestions will be helpful. Should I be changing the firmware/driver? Currently my /lib/firmware has following iwlwifi files /lib/firmware/iwlwifi-1000-5.ucode /lib/firmware/iwlwifi-5000-5.ucode /lib/firmware/iwlwifi-100-5.ucode /lib/firmware/iwlwifi-5150-2.ucode /lib/firmware/iwlwifi-105-6.ucode /lib/firmware/iwlwifi-6000-4.ucode /lib/firmware/iwlwifi-135-6.ucode /lib/firmware/iwlwifi-6000g2a-5.ucode /lib/firmware/iwlwifi-2000-6.ucode /lib/firmware/iwlwifi-6000g2a-6.ucode /lib/firmware/iwlwifi-2030-6.ucode /lib/firmware/iwlwifi-6000g2b-6.ucode /lib/firmware/iwlwifi-3945-2.ucode /lib/firmware/iwlwifi-6050-5.ucode /lib/firmware/iwlwifi-4965-2.ucode Thanks a lot for the help.

    Read the article

  • Parallel Data Warehouse

    - by jchang
    The Microsoft Parallel Data Warehouse diagram was somewhat difficult to understand in terms of the functionality of each subsystem in relation to the configuration of its components. So now that HP has provided a detailed list of the PDW components , the diagram below shows the PDW subsystems with component configuration (InfiniBand, FC, and network connections not shown). Observe that there are three different ProLiant server models, the DL360 G7, DL370 G6 and the DL380 G7, in five different configurations...(read more)

    Read the article

  • Master Data Management Update

    Oracle's Master Data Management suite has seen remarkable development progress in the past year and a half. Leveraging out-of-the-box integration to applications provided by Application Integration Architecture, the cost, risk and time it takes to implement an MDM solution has been cut in half. Oracle Applications are now 'MDM Aware', Data Quality tools have reached state-of-the-art status, and new hubs are coming on line. In this AppsCast, Pascal Laik, VP MDM Products discusses this progress, what it means for Oracle customers, and where we are going from here.

    Read the article

  • Sprite Animation Toolkits for iPhone

    - by Mike Eggleston
    Does anyone know of any good (and preferably free) Sprite Animation Toolkits/Libraries for iOS development? This library should be able to handle the collision detection and the movement of the sprites. Back in the 90's there was a Pascal library called Sprite Animation Toolkit by Ingemar Ragnemalm that handled a lot of the heft to create animations and the such. I am just wondering if there is anything like that in the iOS world?

    Read the article

  • What languages are the kids of today actually programming in? Does anyone have real data?

    - by Gaz Davidson
    Back in the 80s colleges were teaching Pascal because it is easy to learn, while myself and many others like me were learning BASIC because it was not only easy to learn but accessible and also fashionable (for an extremely liberal definition of fashion) It has just occurred to me that empirical data on the actual programming languages kids are choosing to use should be a good indicator of which language would be the ideal first choice for educators. Please note that this question is not "what do you think is a good programming language for kids?"

    Read the article

  • How do I set Ubuntu Bold Font as the window titlebar font?

    - by Ricardo
    I've made a fresh Ubuntu 12.10 install and the Ubuntu Bold font is missing from the font selection screens. This means that if I try to use Ubuntu Tweak to set the title font for windows as "Ubuntu Bold" it does not appear as a choice. The actual file is present in /usr/share. If I use the font in Writer, for example, I can set it to bold without issues. I've tried fc-cache -frv but that's the only thing I can think of.

    Read the article

  • How do I transition from physics and math to programming?

    - by inovaovao
    I'm a physics PhD with little actual programming experience. I've always liked programming and played around with BASIC, Pascal as a teen, but the extent of my experience writing complex programs comes from an introductory course in computer science. Now I've decided that I'm more interested in programming than in physics and started to learn Java. Coming from a physics or math-heavy background, what would be the best strategy to maximize my value in the field?

    Read the article

  • Analyzing I/O performance in Linux

    <b>cmdln.org:</b> "Monitoring and analyzing performance is an important task for any sysadmin. Disk I/O bottlenecks can bring applications to a crawl. What is an IOP? Should I use SATA, SAS, or FC? How many spindles do I need?"

    Read the article

  • GRUB doesn't recognize partitions on one harddisk

    - by knizz
    I have a dualboot computer with Windows Vista (on hd0) and Ubuntu 9.10. The bootloader is GRUB and the windows bootloader lets me decide between Vista and Ubuntu-Installation (broken WuBi). But now (i don't know why that changed) I can't use start the windows-bootloader anymore. I tried "ls" on the grub-prompt and it gave me a list like: (hd0) (hd1) (hd1,0) (hd1,1) (hd1,2) ... (fd0) It recognizes all partitions of hd1 (the ubuntu-harddisk) but not of hd0(the win-disk). .. WHY? Here is the result of the "boot info script" for the technical details: Boot Info Script 0.55 dated February 15th, 2010 ============================= Boot Info Summary: ============================== => Grub 2 is installed in the MBR of /dev/sda and looks for (UUID=a7c510e3-2399-437b-ab92-fa609e48d63f)/boot/grub. => No boot loader is installed in the MBR of /dev/sdb sda1: _________________________________________________________________________ File system: ntfs Boot sector type: Windows Vista/7 Boot sector info: No errors found in the Boot Parameter Block. Operating System: Windows Vista Boot files/dirs: /bootmgr /Boot/BCD /Windows/System32/winload.exe /wubildr.mbr /wubildr sda2: _________________________________________________________________________ File system: ntfs Boot sector type: Windows Vista/7 Boot sector info: No errors found in the Boot Parameter Block. Operating System: Boot files/dirs: sdb1: _________________________________________________________________________ File system: Boot sector type: Unknown Boot sector info: Mounting failed: mount: unbekannter Dateisystemtyp „“ sdb2: _________________________________________________________________________ File system: ntfs Boot sector type: Windows Vista/7 Boot sector info: No errors found in the Boot Parameter Block. Operating System: Boot files/dirs: sdb3: _________________________________________________________________________ File system: Bios Boot Partition Boot sector type: - Boot sector info: sdb4: _________________________________________________________________________ File system: ext4 Boot sector type: - Boot sector info: Operating System: Ubuntu 9.10 Boot files/dirs: /boot/grub/grub.cfg /etc/fstab /boot/grub/core.img sdb5: _________________________________________________________________________ File system: swap Boot sector type: - Boot sector info: =========================== Drive/Partition Info: ============================= Drive: sda ___________________ _____________________________________________________ Platte /dev/sda: 640.1 GByte, 640135028736 Byte 255 Köpfe, 63 Sektoren/Spuren, 77825 Zylinder, zusammen 1250263728 Sektoren Einheiten = Sektoren von 1 × 512 = 512 Bytes Disk identifier: 0x52554d66 Partition Boot Start End Size Id System /dev/sda1 * 2,048 307,202,047 307,200,000 7 HPFS/NTFS /dev/sda2 307,202,048 1,250,258,943 943,056,896 7 HPFS/NTFS Drive: sdb ___________________ _____________________________________________________ Platte /dev/sdb: 640.1 GByte, 640135028736 Byte 255 Köpfe, 63 Sektoren/Spuren, 77825 Zylinder, zusammen 1250263728 Sektoren Einheiten = Sektoren von 1 × 512 = 512 Bytes Disk identifier: 0x00000000 Partition Boot Start End Size Id System /dev/sdb1 1 1,250,263,727 1,250,263,727 ee GPT GUID Partition Table detected. Partition Start End Size System /dev/sdb1 34 262,177 262,144 Microsoft Windows /dev/sdb2 262,178 1,131,253,933 1,130,991,756 Linux or Data /dev/sdb3 1,131,253,934 1,131,255,887 1,954 Bios Boot Partition /dev/sdb4 1,131,255,888 1,245,312,528 114,056,641 Linux or Data /dev/sdb5 1,245,312,529 1,250,263,694 4,951,166 Linux Swap blkid -c /dev/null: ____________________________________________________________ Device UUID TYPE LABEL /dev/sda1 AE1440441440122F ntfs /dev/sda2 3AE66E4DE66E0A09 ntfs data /dev/sdb2 5419D16119DAA4DE ntfs LaufwerkD /dev/sdb4 a7c510e3-2399-437b-ab92-fa609e48d63f ext4 /dev/sdb5 60a0143a-e01b-450a-bbd1-f22059e47b65 swap ============================ "mount | grep ^/dev output: =========================== Device Mount_Point Type Options /dev/sdb4 / ext4 (rw,errors=remount-ro) =========================== sdb4/boot/grub/grub.cfg: =========================== # # DO NOT EDIT THIS FILE # # It is automatically generated by /usr/sbin/grub-mkconfig using templates # from /etc/grub.d and settings from /etc/default/grub # ### BEGIN /etc/grub.d/00_header ### if [ -s /boot/grub/grubenv ]; then have_grubenv=true load_env fi set default="0" if [ ${prev_saved_entry} ]; then saved_entry=${prev_saved_entry} save_env saved_entry prev_saved_entry= save_env prev_saved_entry fi insmod ext2 set root=(hd1,4) search --no-floppy --fs-uuid --set a7c510e3-2399-437b-ab92-fa609e48d63f if loadfont /usr/share/grub/unicode.pf2 ; then set gfxmode=640x480 insmod gfxterm insmod vbe if terminal_output gfxterm ; then true ; else # For backward compatibility with versions of terminal.mod that don't # understand terminal_output terminal gfxterm fi fi if [ ${recordfail} = 1 ]; then set timeout=-1 else set timeout=10 fi ### END /etc/grub.d/00_header ### ### BEGIN /etc/grub.d/05_debian_theme ### set menu_color_normal=white/black set menu_color_highlight=black/white ### END /etc/grub.d/05_debian_theme ### ### BEGIN /etc/grub.d/10_linux ### menuentry "Ubuntu, Linux 2.6.31-20-generic" { recordfail=1 if [ -n ${have_grubenv} ]; then save_env recordfail; fi set quiet=1 insmod ext2 set root=(hd1,4) search --no-floppy --fs-uuid --set a7c510e3-2399-437b-ab92-fa609e48d63f linux /boot/vmlinuz-2.6.31-20-generic root=UUID=a7c510e3-2399-437b-ab92-fa609e48d63f ro quiet splash initrd /boot/initrd.img-2.6.31-20-generic } menuentry "Ubuntu, Linux 2.6.31-20-generic (recovery mode)" { recordfail=1 if [ -n ${have_grubenv} ]; then save_env recordfail; fi insmod ext2 set root=(hd1,4) search --no-floppy --fs-uuid --set a7c510e3-2399-437b-ab92-fa609e48d63f linux /boot/vmlinuz-2.6.31-20-generic root=UUID=a7c510e3-2399-437b-ab92-fa609e48d63f ro single initrd /boot/initrd.img-2.6.31-20-generic } menuentry "Ubuntu, Linux 2.6.31-14-generic" { recordfail=1 if [ -n ${have_grubenv} ]; then save_env recordfail; fi set quiet=1 insmod ext2 set root=(hd1,4) search --no-floppy --fs-uuid --set a7c510e3-2399-437b-ab92-fa609e48d63f linux /boot/vmlinuz-2.6.31-14-generic root=UUID=a7c510e3-2399-437b-ab92-fa609e48d63f ro quiet splash initrd /boot/initrd.img-2.6.31-14-generic } menuentry "Ubuntu, Linux 2.6.31-14-generic (recovery mode)" { recordfail=1 if [ -n ${have_grubenv} ]; then save_env recordfail; fi insmod ext2 set root=(hd1,4) search --no-floppy --fs-uuid --set a7c510e3-2399-437b-ab92-fa609e48d63f linux /boot/vmlinuz-2.6.31-14-generic root=UUID=a7c510e3-2399-437b-ab92-fa609e48d63f ro single initrd /boot/initrd.img-2.6.31-14-generic } ### END /etc/grub.d/10_linux ### ### BEGIN /etc/grub.d/20_memtest86+ ### menuentry "Memory test (memtest86+)" { linux16 /boot/memtest86+.bin } menuentry "Memory test (memtest86+, serial console 115200)" { linux16 /boot/memtest86+.bin console=ttyS0,115200n8 } ### END /etc/grub.d/20_memtest86+ ### ### BEGIN /etc/grub.d/30_os-prober ### menuentry "Windows Vista (loader) (on /dev/sda1)" { insmod ntfs set root=(hd0,1) search --no-floppy --fs-uuid --set ae1440441440122f chainloader +1 } ### END /etc/grub.d/30_os-prober ### ### BEGIN /etc/grub.d/40_custom ### # This file provides an easy way to add custom menu entries. Simply type the # menu entries you want to add after this comment. Be careful not to change # the 'exec tail' line above. ### END /etc/grub.d/40_custom ### =============================== sdb4/etc/fstab: =============================== # /etc/fstab: static file system information. # # Use 'blkid -o value -s UUID' to print the universally unique identifier # for a device; this may be used with UUID= as a more robust way to name # devices that works even if disks are added and removed. See fstab(5). # # <file system> <mount point> <type> <options> <dump> <pass> proc /proc proc defaults 0 0 # / was on /dev/sdb4 during installation UUID=a7c510e3-2399-437b-ab92-fa609e48d63f / ext4 errors=remount-ro 0 1 # swap was on /dev/sdb5 during installation UUID=60a0143a-e01b-450a-bbd1-f22059e47b65 none swap sw 0 0 /dev/scd0 /media/cdrom0 udf,iso9660 user,noauto,exec,utf8 0 0 /dev/fd0 /media/floppy0 auto rw,user,noauto,exec,utf8 0 0 =================== sdb4: Location of files loaded by Grub: =================== 583.8GB: boot/grub/core.img 583.8GB: boot/grub/grub.cfg 579.7GB: boot/initrd.img-2.6.31-14-generic 580.0GB: boot/initrd.img-2.6.31-20-generic 579.7GB: boot/vmlinuz-2.6.31-14-generic 579.8GB: boot/vmlinuz-2.6.31-20-generic 580.0GB: initrd.img 579.7GB: initrd.img.old 579.8GB: vmlinuz 579.7GB: vmlinuz.old =========================== Unknown MBRs/Boot Sectors/etc ======================= Unknown BootLoader on sdb1 00000000 54 34 dc 3b 8b ff 6c fa 3e 59 3d 24 25 af 5f 9b |T4.;..l.>Y=$%._.| 00000010 72 f8 36 3d 56 30 22 fd c6 08 5e 39 7f dc 29 48 |r.6=V0"...^9..)H| 00000020 48 e5 24 52 77 b0 fc 64 b6 ce 48 c3 07 ce b5 81 |H.$Rw..d..H.....| 00000030 06 68 60 4f 6e fb 83 92 df 3a 54 b9 df 21 2a cd |.h`On....:T..!*.| 00000040 1e 2f e2 49 fe cf 81 2d 52 17 1a 4e 66 b4 f3 f0 |./.I...-R..Nf...| 00000050 41 25 e3 96 26 28 fe 19 61 72 75 f8 40 a3 b7 ef |A%..&(..aru.@...| 00000060 5f 79 dc cb 28 44 44 7c 9b 9a 7b 6c 4b 4b 60 0f |_y..(DD|..{lKK`.| 00000070 a9 97 87 bc 85 9f db bb d2 1a 88 9f aa 49 18 d5 |.............I..| 00000080 92 2d db 7e fe f7 8d 7a 18 c0 33 c5 bd 7a 46 07 |.-.~...z..3..zF.| 00000090 c8 27 13 66 94 49 62 9f bc 99 56 55 25 fb 94 a9 |.'.f.Ib...VU%...| 000000a0 3f b2 a7 0a 87 d0 a4 4e 51 f1 09 02 c4 29 eb ff |?......NQ....)..| 000000b0 26 3b 51 3e 5a 0c db ee a6 57 a7 c3 ba a1 74 90 |&;Q>Z....W....t.| 000000c0 ee 70 08 18 cc b8 d0 22 ce 96 c7 cb 68 40 98 20 |.p....."....h@. | 000000d0 49 3d 07 ec df d1 8d cf 19 bc 42 90 70 24 01 b4 |I=........B.p$..| 000000e0 28 cf c6 50 d3 95 5a 1b 18 15 33 c7 b2 a8 95 92 |(..P..Z...3.....| 000000f0 bb 93 fe 18 2b 81 c1 6b 9c 30 f1 65 50 6a 80 3d |....+..k.0.ePj.=| 00000100 74 37 a8 59 a6 51 8a 63 b6 d8 16 9f a9 47 2a 7c |t7.Y.Q.c.....G*|| 00000110 04 a7 fe 69 47 02 bf e9 b7 1b 7a ea 60 5c 3c 53 |...iG.....z.`\<S| 00000120 5b 10 78 dc 4d d2 a8 22 30 45 37 fb 56 06 9f 06 |[.x.M.."0E7.V...| 00000130 aa df cf 87 3a 3e cf 72 f2 e5 a6 c6 aa e2 7c 1c |....:>.r......|.| 00000140 64 c2 fc 80 ce 02 fc 7f 0f c6 60 81 bf cd 3b 5a |d.........`...;Z| 00000150 37 a5 38 1b 0c 1b 39 2e d6 f6 3d a2 36 e5 87 c3 |7.8...9...=.6...| 00000160 17 b5 fd ee 33 c7 ce a3 d9 c2 57 dc ee 85 48 9d |....3.....W...H.| 00000170 33 60 02 cd c5 83 44 44 ea b6 07 25 0a 4b a6 6e |3`....DD...%.K.n| 00000180 fc 51 42 cd 84 0b 65 b6 19 a1 e5 b2 eb 14 0c fa |.QB...e.........| 00000190 24 77 f5 44 6e 5d 39 dd b6 8e cc f8 30 fe 21 46 |$w.Dn]9.....0.!F| 000001a0 9c ff 95 c6 c7 b5 0a df 54 ca d2 ac bc 64 d0 97 |........T....d..| 000001b0 94 54 d9 29 0f 91 60 20 c3 e4 53 c2 b0 e4 40 72 |.T.)..` ..S...@r| 000001c0 7e 25 bc 81 06 ad 05 46 14 a7 e6 71 6b 5c db 9c |~%.....F...qk\..| 000001d0 0a 5e 76 23 ae 06 01 36 98 21 65 2c 90 e7 4b 1a |.^v#...6.!e,..K.| 000001e0 2a 2d 80 a5 48 db 9e 14 e0 9f e9 aa 00 e3 77 32 |*-..H.........w2| 000001f0 0f fd 94 db 55 a6 64 46 be ae ca de da ee 89 68 |....U.dF.......h| 00000200 =======Devices which don't seem to have a corresponding hard drive============== sdc sdd sde

    Read the article

  • New virtualization project and old SAN

    - by Chris
    Hi, We'll start shortly a partial virtualization of our infrastructure and consolidate a dozen servers into virtuals instances. We'll also add some client application virtualization into the mix for good measure. Two HP DL 380 with the new xeons 56xx and 96 GB of memory each running xenserver + xenapp will then take charge of most of our IT needs. So far, so good. One element that is missing from the picture is the storage part. We need some sort of shared storage to enable live motion and other HA features. We have an IBM DS 4300 SAN that we can use for that. But since it's in production since 2005, I'm not sure about such a critical role for a 5yr old part. So my question is: What is the reliability of this kind of equipment after 5 yr ? Can it last 10 yr with no or few problems ? Since our budjet is tight, not buying another SAN will be a big plus. This lead me to another question: FC disks cost an arm and a leg from IBM. When I type the replacement # in google (for example IBM 300GB 15K 4GBPS FC HDD 42D0410), I can find it at a fraction of the price at various sites. So am I stupid to buy from IBM or naive to trust 3rd party reseller ?? Thanks, Chris

    Read the article

  • ISC DHCPD IPv6 for multiple interfaces

    - by Seoman
    I want to assign multiple IPv6 to a server with multiple NIC. As IPv6 RFC defines, each server has a unique DUID that can have one of the 3 formats (LL, LLT or enterprise). And each NIC has an IAID. So a request from NIC1 its the DUID and the IAID of the NIC1 and the request from NIC2 its the same DUID but the IAID its different. The problem is that from a Centos box, when I ask for an IP in 2 different interfaces, I get the same IP. I can't find how to specify host entry based on DUID and the IAID. I see some people generating a unique DUID based on the MAC of the NIC but this is not IPv6 RFC says. What I tried is: host entry1 { host-identifier option dhcp6.client-id 00:01:00:01:19:fc:f8:1c:52:54:00:7e:c9:ec; option dhcp6.ia-na "00:09:40:5d"; fixed-address6 2001:db8:0:1::202; } host entry2 { host-identifier option dhcp6.client-id 00:01:00:01:19:fc:f8:1c:52:54:00:7e:c9:ec; option dhcp6.ia-na "00:7e:c9:ec"; fixed-address6 2001:db8:0:1::201; } This causes a Segmentation Fault in the client (what is scary...). I guess is not the right use for ia-na option but I don't see any other option.

    Read the article

  • Decyphering Seagate drive model numbers?

    - by Stefan Lasiewski
    I'm comparing Seagate's Enterprise and Desktop drives for a variety of old and new servers. These servers come from different generations, so options like size (73GB, 2TB) and interface (SATA vs SAS 3.0Gbps vs SAS 6Gbps vs SCSI Ultra320) are widely variable. I'm trying to compare the sizes, speeds and interfaces, but I'm getting thrown off by different models. Also, their website is not the best. Does anyone know of a documented explanation of the Seagate model numbers? And is there a single spreadsheet which compares the features for all drives (or all 'Enterprise' drives?). Seagate drives have model numbers like this: Model ST3600057SS 6-Gb/s SAS 600 GB None at Cheetah® 15K Hard Drives Model ST373455LW Ultra320 SCSI 73.4 GB 68-Pin LW at Cheetah® 15K Hard Drives Model ST32000644NS SATA 3Gb/s 2 TB None at Constellation™ ES Hard Drives Model ST973452SS 6-Gb/s SAS 73 GB None Savvio® 15K Hard Drives Model ST9200011FS SATA 3Gb/s 200 GB Pulsar™ Solid State Drives I understand the model numbers read something like this: ST - SOMETHING1 - SIZE - SOMETHING2 - INTERFACE Where the fields mean something like this: ST : For 'Seagate'? 'Seagate Technoligies'? SOMETHING1 - This field has number, but I'm not sure what that represents. SIZE - Size in Gigabytes. This is a number like '73' or '300' or '2000' SOMETHING2 - This field also has a number, but I'm not sure what it means. INTERFACE - This field seems to indicate the Interface. 'SS' means SAS, 'FC' means Fibre Channel, but I don't see how to distinguish between 6Gbps SAS and 3Gbps SAS, or different SATA or FC speeds. I don't see a field which indicates the RPM (15K , 10K, 7.2K) etc. Is this part of the model number?

    Read the article

  • Data Store/Volume disconnecting. How to resume copy of VMDK?

    - by Serge
    I'm having an issue with my ESXi 4.1 hosts losing the datastore with FC SAN after a power outage. All 3 hosts disconnect so it's definitely a SAN issue. I've tried to resolve the issue on the SAN side with the SAN software support and Adaptec hardware support. No luck there. So I'm stuck with a SAN that will randomly disconnect the volume. I need to get the virtual machines (VMDK files) from the datastore. The problem is I can only get 5-20% before the data store disconnects. I have backups that are slightly older that I can use to replicate the VMDK differences to. What has not worked so far: Powering up the VMs, will boot up for 5-15 minutes then freeze vCenter migrate or clone of VM, will fail after similar period of time vCenter copy/paste of VMDK. Was able to get one 30GB VMDK and no luck after that. vMware Data Recovery. Fails at low %, can't resume, so next backup starts from begining. Veeam Backup & Recovery. Same as above, no resume function. If I can just find a backup solution that will resume from the failed spot that would solve my issue. Anyone have any ideas that I could try? EDIT 1 The SAN is Open-E DSS 6 running on a Supermicro 24 drive enclosure with 4 port Qlogic FC. Adaptec 52445 RAID card.

    Read the article

  • WWNs,WWPNs and Fibre Channel addresses

    - by user238230
    Lots of contradictory on these subjects and I don't know why. My first question is about the 64 bit WWN. One reference claims the terms WWN and WWPN are synonymous. An online source seems to refute this. They say: A WWPN (world wide port name) is the unique identifier for a fibre channel port where a WWN (world wide name) the unique identifier for the node itself. A good example is a dual port HBA. There will be two WWPN's (one for each port) and only a single WWN for the card itself. Question #1: Which is correct? I’m almost positive I read that every “Port” has a WWN. My next question is about the 24 bit FC address that is dynamically allocated to a port when it is introduced to the switch. The Domain ID field is defined as: "a unique number provided to each switch in the fabric." Question #2: Do Domain IDs only apply to switch ports? For example what would the Domain ID be for a HBA? None? The same as the switch port it is connected to? Question #3: My last question is about the Name Server of a switch. A book example shows the routing of a message through the switch. It uses the WWNs of the source and destination ports to route the message. I am assuming that the Name Server must associate the WWN and the FC address in some way in order to route the message, correct?

    Read the article

  • vSphere - datastore falling off a host

    - by Chadddada
    Recently we have been running the vCheck powershell script daily in order to help in monitoring our vSphere ESX 4.0 environment. One of the oddities that we have been seeing is that some of the datastores on the SAN don't always show up on every host. Our hosts are connected redundantly, via FC, to some brocade FC switches, which then connect via fiber to our EMC Ax4 SAN. While all the datastores are presented to each host we have, and they see them initially, they sometimes seem to fall off and are no longer visible. It easy enough to rescan for datastores and add them back to the hosts the hosts but this seems to be an error. Has anyone else seen this or know why it may be happening? Responses to questions: 1. Is it always the same ESX servers that lose their connection? – Scott Warren No this happens randomly on random hosts. If a VM is running on a particular host, of which the VM's disks are on a SAN datastore, then that datastore won't disappear. It seems to happen if a host doesn't touch a datastore for a bit and it just forgets about it.

    Read the article

  • SRM 4 Test Fails with message for some VM : Error: A specified parameter was not correct.

    - by Setesh
    Here are my architecture : For the protected site 4 Host VSphere Enterprise Plus, each one with 2 HBAs FC connected to the switch fabric, connected to an EMC CX4-120 1 VCenter 1 SRM For the recovery site 2 Hosts Vsphere 4 1 Vcenter 1 SRM 1 CX-4-120 The CX4-120 is connected to the second CX4-120 with ISCSI and the MirrorView / Asynchronous. I synchronise for the time 6 Lun on a FC DAE, 2 on a S-ATA DAE I have allocated 30% of the amount synchronised LUN for the SNAPSHOT us, but I have allocated them only on my S-ATA II DAE. It does not make a problem, my snapshot are correctly active. All the installation is new (hardware and software), installed in January with the last files available in download. I have a strange problem, and it's random, sometimes when I run a test on my RP, some VMs have this error : Error: A specified parameter was not correct. I don't know where to look. Any help is appreciated... PS : I have checked on all the VMs, no Floppy disk or CD attached. PS2 : There is severals VMs with RDM and OCFS2 filesystems on it.

    Read the article

  • Slower/cached Linux file system required

    - by Chopper3
    I know it sounds odd but I need a slower or cached filesystem. I have a lot of firewalls that are syslog'ing their data to a pair of Linux VMs which write these files to their 'local' (actually FC SAN attached) ext3-formatted disks and also forward the messages to our Splunk servers. The problem is that the syslog server is writing these syslog messages as hundreds, sometimes thousands, of tiny ~4k writes per second back to our FC SAN - which can handle this workload right now but our FW traffic's going to be growing by at least a factor of 5000% (really) in coming months and that'll be a pain for the SAN, I want to fix the root cause before it's a problem. So I need some help figuring out a way of getting these writes cached or held-off in some way from the 'physical' disks so that the VMs fire off larger, but less frequent, writes - there's no way of avoiding these writes but there's no need for it to do so many tiny ones. I've looked at the various ext3 options, setting noatime and nodiratime but that's not made much of a dent in the problem. Obviously I'm investigating other file systems but thought I'd throw this out in case others have the same problem in the future. Oh and I can't just forward these messages to Splunk, our firewall team insist they're in their original format for diag purposes.

    Read the article

  • BizTalk 2009 - Naming Guidelines

    - by StuartBrierley
    The following is effectively a repost of the BizTalk 2004 naming guidlines that I have previously detailed.  I have posted these again for completeness under BizTalk 2009 and to allow an element of separation in case I find some reason to amend these for BizTalk 2009. These guidlines should be universal across any version of BizTalk you may wish to apply them to. General Rules All names should be named with a Pascal convention. Project Namespaces For message schemas: [CompanyName].XML.Schemas.[FunctionalName]* Examples:  ABC.XML.Schemas.Underwriting DEF.XML.Schemas.MarshmellowTradingExchange * Donates potential for multiple levels of functional name, such as Underwriting.Dictionary.Valuation For web services: [CompanyName].Web.Services.[FunctionalName] Examples: ABC.Web.Services.OrderJellyBeans For the main BizTalk Projects: [CompanyName].BizTalk.[AssemblyType].[FunctionalName]* Examples: ABC.BizTalk.Mappings.Underwriting ABC.BizTalk.Orchestrations.Underwriting * Donates potential for multiple levels of functional name, such as Mappings.Underwriting.Valuations Assemblies BizTalk Assembly names should match the associated Project Namespace, such as ABC.BizTalk.Mappings.Underwriting. This pertains to the formal assembly name and the DLL name. The Solution name should take the name of the main project within the solution, and also therefore the namespace for that project. Although long names such as this can be unwieldy to work with, the benefits of having the full scope available when the assemblies are installed on the target server are generally judged to outweigh this inconvenience. Messaging Artifacts Artifact Standard Notes Example Schema <DescriptiveName>.xsd   .NET Type name should match, without file extension.    .NET Namespace will likely match assembly name. PurchaseOrderAcknowledge_FF.xsd  or FNMA100330_FF.xsd Property Schema <DescriptiveName>.xsd Should be named to reflect possible common usage across multiple schemas  IspecMessagePropertySchema.xsd UnderwritingOrchestrationKeys.xsd Map <SourceSchema>2<DestinationSchema>.btm Exceptions to this may be made where the source and destination schemas share the majority of the name, such as in mainframe web service maps InstructionResponse2CustomEmailRequest.btm (exception example) AccountCustomerAddressSummaryRequest2MainframeRequest.btm Orchestration <DescriptiveName>.odx   GetValuationReports.odx SendMTEDecisionResponse.odx Send/Receive Pipeline <DescriptiveName>.btp   ValidatingXMLReceivePipeline.btp FlatFileAssembler.btp Receive Port A plainly worded phrase that will clearly explain the function.    FraudPreventionServices LetterProcessing   Receive Location A plainly worded phrase that will clearly explain the function.  ? Do we want to include the transport type here ? Arrears Web Service Send Port Group A plainly worded phrase that will clearly explain the function.   Customer Updates Send Port A plainly worded phrase that will clearly explain the function.    ABCProductUpdater LogLendingPolicyOutput Parties A meaningful name for a Trading Partner. If dealing with multiple entities within a Trading Partner organization, the Organization name could be used as a prefix.   Roles A meaningful name for the role that a Trading Partner plays.     Orchestration Workflow Shapes Shape Standard Notes Example Scopes <DescriptionOfContainedWork> or <DescOfcontainedWork><TxType>   Including info about transaction type may be appropriate in some situations where it adds significant documentation value to the diagram. HandleReportResponse         Receive Receive<MessageName> Typically, MessageName will be the same as the name of the message variable that is being received “into”. ReceiveReportResponse Send Send<MessageName> Typically, MessageName will be the same as the name of the message variable that is being sent. SendValuationDetailsRequest Expression <DescriptionOfEffect> Expression shapes should be named to describe the net effect of the expression, similar to naming a method.  The exception to this is the case where the expression is interacting with an external .NET component to perform a function that overlaps with existing BizTalk functionality – use closest BizTalk shape for this case. CreatePrintXML Decide <DescriptionOfDecision> A description of what will be decided in the “if” branch Report Type? Perform MF Save? If-Branch <DescriptionOfDecision> A (potentially abbreviated) description of what is being decided Mortgage Valuation Yes Else-Branch Else Else-branch shapes should always be named “Else” Else Construct Message (Assign) Create<Message> (for Construct)     <ExpressionDescription> (for expression) If a Construct shape contains a message assignment, it should be prefixed with “Create” followed by an abbreviated name of the message being assigned.    The actual message assignment shape contained should be named to describe the expression that is contained. CreateReportDataMV   which contains expression: ExtractReportData Construct Message (Transform) Create<Message> (for Construct)   <SourceSchema>2<DestSchema> (for transform) If a Construct shape contains a message transform, it should be prefixed with “Create” followed by an abbreviated name of the message being assigned.   The actual message transform shape contained should generally be named the same as the called map.  CreateReportDataMV   which contains transform: ReportDataMV2ReportDataMV                 Construct Message (containing multiple shapes)   If a Construct Message shape uses multiple assignments or transforms, the overall shape should be named to communicate the net effect, using no prefix.     Call/Start Orchestration Call<OrchestrationName>   Start<OrchestrationName>     Throw Throw<ExceptionType> The corresponding variable name for the exception type should (often) be the same name as the exception type, only camel-cased. ThrowRuleException, which references the “ruleException” variable.     Parallel <DescriptionOfParallelWork> Parallel shapes should be named by a description of what work will be done in parallel   Delay <DescriptionOfWhatWaitingFor> Delay shapes should be named by a description of what is being waited for.  POAcknowledgeTimeout Listen <DescriptionOfOutcomes> Listen shapes should be named by a description that captures (to the degree possible) all the branches of the Listen shape POAckOrTimeout FirstShippingBid Loop <DescriptionOfLoop> A (potentially abbreviated) description of what the loop is. ForEachValuationReport WhileErrorFlagTrue Role Link   See “Roles” in messaging naming conventions above.   Suspend <ReasonDescription> Describe what action an administrator must take to resume the orchestration.  More detail can be passed to error property – and should include what should be done by the administrator before resuming the orchestration. ReEstablishCreditLink Terminate <ReasonDescription> Describe why the orchestration terminated.  More detail can be passed to error property. TimeoutsExpired Call Rules Call<PolicyName> The policy name may need to be abbreviated. CallLendingPolicy Compensate Compensate or Compensate<TxName> If the shape compensates nested transactions, names should be suffixed with the name of the nested transaction – otherwise it should simple be Compensate. CompensateTransferFunds Orchestration Types Type Standard Notes Example Multi-Part Message Types <LogicalDocumentType>   Multi-part types encapsulate multiple parts.  The WSDL spec indicates “parts are a flexible mechanism for describing the logical abstract content of a message.”  The name of the multi-part type should correspond to the “logical” document type, i.e. what the sum of the parts describes. InvoiceReceipt   (which might encapsulate an invoice acknowledgement and a payment voucher.) Multi-Part Messsage Part <SchemaNameOfPart> Should be named (most often) simply for the schema (or simple type) associated with the part. InvoiceHeader Messages <SchemaName> or <MuliPartMessageTypeName> Should be named based on the corresponding schema type or multi-part message type.  If there is more than one variable of a type, name for its use within the orchestration. ReportDataMV UpdatedReportDataMV Variables <DescriptiveName>   TargetFilePath StringProcessor Port Types <FunctionDescription>PortType Should be named to suggest the nature of an endpoint, with pascal casing and suffixed with “PortType”.   If there will be more than one Port for a Port Type, the Port Type should be named according to the abstract service supplied.   The WSDL spec indicates port types are “a named set of abstract operations and the abstract messages involved” that also encapsulates the message pattern (i.e. one-way, request-response, solicit-response) that all operations on the port type adhere to. ReceiveReportResponsePortType  or CallEAEPortType (This is a two way port, so Receove or Send alone would not be appropriate.  Could have been ProcessEAERequestPortType etc....) Ports <FunctionDescription>Port Should be named to suggest a grouping of functionality, with pascal casing and suffixed with “Port.”  ReceiveReportResponsePort CallEAEPort Correlation types <DescriptiveName> Should be named based on the logical name of what is being used to correlate.  PurchaseOrderNumber Correlation sets <DescriptiveName> Should be named based on the corresponding correlation type.  If there is more than one, it should be named to reflect its specific purpose within the orchestration.   PurchaseOrderNumber Orchestration parameters <DescriptiveName> Should be named to match the caller’s names for the corresponding variables where appropriate.

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >