Search Results

Search found 3443 results on 138 pages for 'byte'.

Page 108/138 | < Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >

  • Server 2012, Jumbo Frames - should I expect problems?

    - by TomTom
    Ok, this sound might stupid - but is there any negative on just enabling jumbo frames in practice? From what I understand: Any switch or ethernet adapter that sees a jumbo frame it can not handle will just drop it. TCP is not a problem as max frame size is negotiated in the setinuo phase. UCP is a theoretical problem as a server may just send a LARGE UDP packet that gets dropped on the way. Practically though, as UDP is packet based, I do not really think any software WOULD send a UDP packet larger than 1500 bytes net without app level configuration changes - at least this is how I do my programming, as it is quite hard to get a decent MTU size for that without testing yourself, so you fall back in programming to max 1500 packets. The network in question is a standard small business network - we upgraded now from a non managed 24 port switch to a 52 port switch with 4 10g ports (netgear - quite cheap) and will mov a file server to 10g for also ISCSI serving. All my equipment on the Ethernet level can handle minimum 9000 bytes and due to local firewalls I really want to get packets larger (less firewall processing), but the network is also NAT'ed to the internet. On top, different machines move around (download) large files (multi gigabyte area) quite often for processing. The question is - can I expect problems when I just enable jumbo frames? Again, this is not totally ignorance - I just don't see programs sending more than 1500 byte UDP packets (if that is a practical problem please tell me) and for TCP the MTU is negotiated anyway. if there is a problem I can move to a dedicated VLAN, but this has it's own shares of problems as basically most workstations must then be on both VLAN's.

    Read the article

  • Problem routing between directly connected Subnets w/ ASA-5510

    - by Zephyr Pellerin
    This is an issue I've been struggling with for quite some time, with a seemingly simple answer (Aren't all IT problems?). And that is the problem of passing traffic between two directly connected subnets with an ASA While I'm aware that best practice is to have Internet - Firewall - Router, in many cases this isn't possible. For example, In have an ASA with two interfaces, named OutsideNetwork (10.19.200.3/24) and InternalNetwork (10.19.4.254/24). You'd expect Outside to be able to get to, say, 10.19.4.1, or at LEAST 10.19.4.254, but pinging the interface gives only bad news. Result of the command: "ping OutsideNetwork 10.19.4.254" Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 10.19.4.254, timeout is 2 seconds: ????? Success rate is 0 percent (0/5) Naturally, you'd assume that you could add a static route, to no avail. [ERROR] route Outsidenetwork 10.19.4.0 255.255.255.0 10.19.4.254 1 Cannot add route, connected route exists At this point, you might gander if its a NAT or Access list problem. access-list Outsidenetwork_access_in extended permit ip any any access-list Internalnetwork_access_in extended permit ip any any There is no dynamic nat (or static nat for that matter), and Unnatted traffic is permitted. When I try pinging the above address (10.19.4.254 from Outsidenetwork), I get this error message from level 0 logging (debugging). Routing failed to locate next hop for icmp from NP Identity Ifc:10.19.200.3/0 to Outsidenetwork:10.19.4.1/0 This led me to set same-security traffic permit, and assigned the same, lesser and greater security numbers between the two interfaces. Am I overlooking something obvious? Is there a command to set static routes that are classified higher than connected routes?

    Read the article

  • Problems configuring logstash for email output

    - by user2099762
    I'm trying to configure logstash to send email alerts and log output in elasticsearch / kibana. I have the logs successfully syncing via rsyslog, but I get the following error when I run /opt/logstash-1.4.1/bin/logstash agent -f /opt/logstash-1.4.1/logstash.conf --configtest Error: Expected one of #, {, ,, ] at line 23, column 12 (byte 387) after filter { if [program] == "nginx-access" { grok { match = [ "message" , "%{IPORHOST:remote_addr} - %{USERNAME:remote_user} [%{HTTPDATE:time_local}] %{QS:request} %{INT:status} %{INT:body_bytes_sent} %{QS:http_referer} %{QS:http_user_agent}” ] } } } output { stdout { } elasticsearch { embedded = false host = " Here is my logstash config file input { syslog { type => syslog port => 5544 } } filter { if [program] == "nginx-access" { grok { match => [ "message" , "%{IPORHOST:remote_addr} - %{USERNAME:remote_user} \[% {HTTPDATE:time_local}\] %{QS:request} %{INT:status} %{INT:body_bytes_sent} %{QS:http_referer} %{QS:http_user_agent}” ] } } } output { stdout { } elasticsearch { embedded => false host => "localhost" cluster => "cluster01" } email { from => "[email protected]" match => [ "Error 504 Gateway Timeout", "status,504", "Error 404 Not Found", "status,404" ] subject => "%{matchName}" to => "[email protected]" via => "smtp" body => "Here is the event line that occured: %{@message}" htmlbody => "<h2>%{matchName}</h2><br/><br/><h3>Full Event</h3><br/><br/><div align='center'>%{@message}</div>" } } I've checked line 23 which is referenced in the error and it looks fine....I've tried taking out the filter, and everything works...without changing that line. Please help

    Read the article

  • Under FreeBSD, can a VLAN interface have a smaller MTU than the primary interface?

    - by larsks
    I have a system with two physical interfaces, combined into a LACP aggregation group. That LACP channel has two VLANs, one untagged (the "native vlan") and one using VLAN tagging. This gives us: lagg0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 options=19b<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,VLAN_HWCSUM,TSO4> ether 00:25:90:1d:fe:8e inet 10.243.24.23 netmask 0xffffff00 broadcast 10.243.24.255 media: Ethernet autoselect status: active laggproto lacp laggport: em1 flags=1c<ACTIVE,COLLECTING,DISTRIBUTING> laggport: em0 flags=1c<ACTIVE,COLLECTING,DISTRIBUTING> vlan0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 options=3<RXCSUM,TXCSUM> ether 00:25:90:1d:fe:8e inet 10.243.16.23 netmask 0xffffff80 broadcast 10.243.16.127 media: Ethernet autoselect status: active vlan: 610 parent interface: lagg0 Is it possible to set a 9K MTU on lagg0 while preserving the 1500 byte MTU on vlan0? Normally I would simply try this out, but this is actually on a vendor-supported platform and I am loathe to make changes "behind the back" of their administration interface. This system is roughly FreeBSD 7.3.

    Read the article

  • external drive and CentOS - Reset high speed USB device number

    - by Phil
    I have 2 external drives (3TB) and both will not work with my centOS Box. Tested them in windows ( different machine ) No problems ( 2.6.32-279.9.1.el6.i686 ) dmesg reports: usb 2-2: new high speed USB device number 3 using ehci_hcd usb 2-2: New USB device found, idVendor=2109, idProduct=0700 usb 2-2: New USB device strings: Mfr=1, Product=2, SerialNumber=3 usb 2-2: Product: USB 3.0 SATA Bridge usb 2-2: Manufacturer: VIA Labs, Inc. usb 2-2: SerialNumber: 0000000000006121 usb 2-2: configuration #1 chosen from 1 choice scsi6 : SCSI emulation for USB Mass Storage devices usb-storage: device found at 3 usb-storage: waiting for device to settle before scanning usb-storage: device scan complete scsi 6:0:0:0: Direct-Access ST3000DM 001-9YN166 CC4B PQ: 0 ANSI: 2 sd 6:0:0:0: Attached scsi generic sg3 type 0 sd 6:0:0:0: [sdd] Very big device. Trying to use READ CAPACITY(16). sd 6:0:0:0: [sdd] 5860533165 512-byte logical blocks: (3.00 TB/2.72 TiB) sd 6:0:0:0: [sdd] Write Protect is off sd 6:0:0:0: [sdd] Mode Sense: 00 06 00 00 sd 6:0:0:0: [sdd] Assuming drive cache: write through sd 6:0:0:0: [sdd] Very big device. Trying to use READ CAPACITY(16). sd 6:0:0:0: [sdd] Assuming drive cache: write through sdd: sdd1 sd 6:0:0:0: [sdd] Very big device. Trying to use READ CAPACITY(16). sd 6:0:0:0: [sdd] Assuming drive cache: write through sd 6:0:0:0: [sdd] Attached SCSI disk Tyring to use cfdisk / fdisk / gdisk or even fdisk -l results in the program hanging and dmesg reports: usb 2-2: reset high speed USB device number 3 using ehci_hcd usb 2-2: reset high speed USB device number 3 using ehci_hcd usb 2-2: reset high speed USB device number 3 using ehci_hcd I have the same 2 drives physically installed in the computer via SATA Any Ideas?

    Read the article

  • How to make gpg2 flush the stream?

    - by Vi
    I want to get some slowly flowing data saved in encrypted form at the device which can be turned off abruptly. But gpg2 seems to not to flush it's output frequently and I get broken files when I try to read such truncated file. vi@vi-notebook:~$ cat asdkfgmafl asdkfgmafl ggggg ggggg 2342 2342 cat behaves normally. I see the output right after input. vi@vi-notebook:~$ gpg2 -er _Vi --batch ?pE??x...(more binary data here)....???-??.... asdfsadf 22223 sdfsdfasf Still no data... Still no output... ^C gpg: signal Interrupt caught ... exiting vi@vi-notebook:~$ gpg2 -er _Vi --batch /tmp/qqq skdmfasldf gkvmdfwwerwer zfzdfdsfl ^\ gpg: signal Quit caught ... exiting Quit vi@vi-notebook:~$ gpg2 " 2048-bit ELG key, ID 78F446CA, created 2008-01-06 (main key ID 1735A052) gpg: [don't know]: 1st length byte missing vi@vi-notebook:~$ # Where is my "skdmfasldf" How to make gpg2 to handle such case? I want it to put enough output to reconstruct each incoming chunk of input. (Also fsyncing after each output can be benefitial as an additional option). Should I use other tool (I need pubkey encryption).

    Read the article

  • What's going on with traceroute?

    - by Kevin
    The following is what happens when I run traceroute from a certain location: # traceroute google.com traceroute to google.com (74.125.227.39), 30 hops max, 60 byte packets 1 gateway.local.enactpc.com (10.0.0.1) 0.138 ms 0.101 ms 0.084 ms 2 * * * 3 * * * 4 * * * 5 * * * 6 * * * 7 * * * 8 * * * 9 * * * 10 * * * 11 * * * 12 * * * 13 * * * 14 * * * 15 * * * 16 * * * 17 * * * 18 * * * 19 * * * 20 * * * 21 * * * 22 * * * 23 * * * 24 * * * 25 * * * 26 * * * 27 * * * 28 * * * 29 * * * 30 * * * Absolutely nothing of interest... Now, originally I thought this was just a fact of the location's network set up. (I assume they block pings or something...) However, watch what happens when I use nmap to run a traceroute... # nmap -sP --traceroute google.com Starting Nmap 5.21 ( http://nmap.org ) at 2012-09-25 22:18 CDT Nmap scan report for google.com (74.125.227.40) Host is up (0.034s latency). Hostname google.com resolves to 11 IPs. Only scanned 74.125.227.40 rDNS record for 74.125.227.40: dfw06s06-in-f8.1e100.net TRACEROUTE (using proto 1/icmp) HOP RTT ADDRESS 1 0.19 ms gateway.local.enactpc.com (10.0.0.1) 2 1.93 ms 99-20-92-1.lightspeed.austtx.sbcglobal.net (99.20.92.1) 3 25.61 ms 99-20-92-2.lightspeed.austtx.sbcglobal.net (99.20.92.2) 4 ... 6 7 23.68 ms 12.83.68.137 8 31.30 ms gar23.dlstx.ip.att.net (12.122.85.73) 9 ... 10 31.82 ms 72.14.233.65 11 32.27 ms 209.85.250.77 12 32.98 ms dfw06s06-in-f8.1e100.net (74.125.227.40) Nmap done: 1 IP address (1 host up) scanned in 3.29 seconds When using nmap I get A LOT more results than with traceroute, why? Note, I checked, and the difference in target IP addresses is not related...

    Read the article

  • After adding skip-innodb mysql doesn't start

    - by Pentium10
    I am trying to setup these values: #skip-bdb #skip-locking #skip-innodb When I add them to /etc/mysql/my.cnf and even if I turn ON of of, them after I do the service restart mysql fails to start, and no error message printed. sudo service mysql restart [ ok ] Stopping MySQL database server: mysqld. [FAIL] Starting MySQL database server: mysqld . . . . . . . . . . . . . . failed! Previously I made sure that I have no InnoDB tables, and all files of that type were removed. I tried looking for error files but I couldn't locate it: /var/log/mysql.err is a 0 byte file /var/log/mysql folder has no files rsyslog was changed in past with inetutils-syslogd, and this might have changed the log files, and it could be the reason why I don't see any error logs, and I am stuck how to look or go forward.

    Read the article

  • Linux kernel - can't access sda16 & sda17

    - by osgx
    I can't access sda16 sda17 and higher partitions from my linux. This linux is rather debian (very old); kernel 2.6.23. So, I know that so old linux kernel can't access 16 partitions on single sata disk. What version of kernel should I use to be able access sda16, sda17 etc? I want to update only a kernel, not a whole Linux distribution. PS. There is an WindowsNT kernel which can access and format 16, 17 or higher partition, but my intention is to use sda16 and sda17 from linux (I want Linux Kernel). PPS: dmesg: sd 2:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA sda: sda1 sda2 sda3 sda4 < sda5 sda6 sda7 sda8 sda9 sda10 sda11 sda12 sda13 sda14 sda15 > sd 2:0:0:0: [sda] Attached SCSI disk sd 4:0:0:0: [sdb] xxx 512-byte hardware sectors ... So, there is no mapping of sda16, sda17, ... to sdb. Sdb is the second physical hard drive.

    Read the article

  • Juniper NetScreen NS-5GT traffic monitoring

    - by blah
    I've done casual research into the subject and am truly dismayed at the lack of compatible tools for such a simple task. Maybe someone can provide assistance. We have a NetScreen NS-5GT in the office. I need to be able to get a glance of current traffic per endpoint -- I think the equivalent of 'get sessions' with byte counts/rates. I don't care about bars, graphs, and reports. Something as simple as a classic software firewall display would be perfect. I can't shell out money on something real like SolarWinds products, so a free solution is essential. I'm willing to do a little work but refuse to program something from scratch. It's not prudent right now for me to install a hub or otherwise mess around physically. There must be something out there I can use, maybe in combination. I don't believe I'm asking too much. Specific answers only please, e.g. monitoring software you know will actually work with this antiquated device. I've read about general approaches to the broader problem dozens of times already.

    Read the article

  • C# sends SQL data 4 times less from one box than from another

    - by Bobb
    W2003, .NET 3.5, SQL 2008 I have prod and UAT app servers deployed in 2 different data centres. I have a C# app which reads text file, parse the text and sends the data to the SQL in bulk. SQL server is in US and the app servers are in London (but in different places). All POPs have dedicated network connections. There is no public internet involved. When the app runs on UAT server I can see in Perfmon that the Send byte/sec is x4 higher than from production server. My estimate is that one server outputs at 1 MB/s and the other at 250 KB/s rate. My suspicion immediately is that there is a router on one of the DCs which shapes traffic or does QoS limitation on traffice from London to US. However support and Windows team and networkig team all are saying that there are no differences in neither networking config on the 2 DCs nor NIC config on the 2 app server... How to find out why is the networking bottlneck is 4 times tighter in one place than in the other? What can I do about it?

    Read the article

  • How can the route between two private IPs go via public IPs?

    - by Gilles
    I'm trying to understand what this output from traceroute means. I changed the IP addresses for privacy but retained the public/private IP range distinction. traceroute.db -e -n 10.1.1.9 traceroute to (10.1.1.9), 30 hops max, 60 byte packets 1 10.0.0.1 0.596 ms 0.588 ms 0.577 ms 2 10.0.0.2 1.032 ms 1.029 ms 1.084 ms 3 10.0.0.3 3.360 ms 3.355 ms 3.338 ms 4 23.0.0.4 3.974 ms 4.592 ms 4.584 ms 5 23.0.0.5 13.442 ms 13.445 ms 13.434 ms 6 45.0.0.6 13.195 ms 12.924 ms 12.913 ms 7 67.0.0.7 52.088 ms 51.683 ms 52.040 ms 8 10.1.1.8 46.878 ms 44.575 ms 44.815 ms 9 10.1.1.9 45.932 ms 45.603 ms 45.593 ms The first 10.0.* range is inside my organisation. The last 10.1.* range is another site of my organisation. The intermediate addresses belong to various ISPs. I expect that there is some kind of VPN between the two sites, but I don't know much about our network topology. What I don't understand is how the route can go from a private address through public addresses back into private addresses. Searching led me to Public IPs on MPLS Traceroute, which gives a possible explanation: MPLS. Is MPLS the only possible or most likely explanation? Otherwise what does this tell me about our network infrastructure? Bonus question for my edification: in this scenario, who is generating the ICMP TTL exceeded packets and if relevant mangling their source and destination addresses?

    Read the article

  • Bandwidth monitoring with iptables for non-router machine

    - by user1591276
    I came across this tutorial here that describes how to monitor bandwidth using iptables. I wanted to adapt it for a non-router machine, so I want to know how much data is going in/coming out and not passing through. Here are the rules I added: iptables -N ETH0_IN iptables -N ETH0_OUT iptables -I INPUT -i eth0 -j ETH0_IN iptables -I OUTPUT -o eth0 -j ETH0_OUT And here is a sample of the output: user@host:/tmp$ sudo iptables -x -vL -n Chain INPUT (policy ACCEPT 1549 packets, 225723 bytes) pkts bytes target prot opt in out source destination 199 54168 ETH0_IN all -- eth0 * 0.0.0.0/0 0.0.0.0/0 Chain FORWARD (policy ACCEPT 0 packets, 0 bytes) pkts bytes target prot opt in out source destination Chain OUTPUT (policy ACCEPT 1417 packets, 178128 bytes) pkts bytes target prot opt in out source destination 201 19597 ETH0_OUT all -- * eth0 0.0.0.0/0 0.0.0.0/0 Chain ETH0_IN (1 references) pkts bytes target prot opt in out source destination Chain ETH0_OUT (1 references) pkts bytes target prot opt in out source destination As seen above, there are no packet and byte values for ETH0_IN and ETH0_OUT, which is not the same result in the tutorial I referenced. Is there a mistake that I made somewhere? Thanks for your time.

    Read the article

  • Can applications use all of the memory in Windows 8?

    - by Barleyman
    Windows 7 (and Windows Vista) have a built-in limit of not being able to use the last 25% of RAM. You will get a low memory warning when you get close to the limit. Even if you disable that warning, applications will run out of memory and crash since the OS will refuse to allocate memory from that last 25%. That was fine when Vista was designed, when machines had 1 GB of total memory, but is pretty daft for today's 8 GB machines. Yes, the system will run cache, etc. on that extra 2 GB, but running out of memory when you have "merely" 2 GB left.... NB: this has nothing to do with the page file. If you limit the page file to a sensible size like 2 GB, you will still see this behavior. The system will cram the page file to the last byte while refusing to touch that 1/4th of the RAM. Does Windows 8 change this behavior? Is there now some fixed minimum free RAM requirement, like 512 MB, or is it still 25%? Can you actually adjust the low memory limit?

    Read the article

  • Discrepancy in file size on disk and ls output

    - by smokinguns
    I have a script that checks for gzipped file sizes greater than 1MB and outputs files along with their sizes as a report. This is the code: myReport=`ls -ltrh "$somePath" | egrep '\.gz$' | awk '{print $9,"=>",$5}'` # Count files that exceed 1MB oversizeFiles=`find "$somePath" -maxdepth 1 -size +1M -iname "*.gz" -print0 | xargs -0 ls -lh | wc -l` if [ $oversizeFiles -eq 0 ];then status="PASS" else status="CHECK FAILED. FOUND FILES GREATER THAN 1MB" fi echo -e $status"\n"$myReport The problem is that ls command outputs the files sizes as 1.0MB in the report but the status is "FAIL" as "$oversizeFiles" variable's value is 2. I checked the file sizes on disk and 2 files are 1.1MB. Why this discrepancy? How should I modify the script so that I can generate an accurate report? BTW, I'm on a Mac. Here is what man page for "find" says on my Mac OSX: -size n[ckMGTP] True if the file's size, rounded up, in 512-byte blocks is n. If n is followed by a c,then the primary is true if the file's size is n bytes (characters). Similarly if n is followed by a scale indicator then the file's size is compared to n scaled as: k kilobytes (1024 bytes) M megabytes (1024 kilobytes) G gigabytes (1024 megabytes) T terabytes (1024 gigabytes) P petabytes (1024 terabytes)

    Read the article

  • Long 'pause' after copying large files on windows 2008

    - by Ian
    I have a mystery regarding pauses after file copies on windows server 2088 (and other releases) When copying large files, like vhds, to locally attached USB disks I often see a long pause after the copy has completed 100%. As an example: robocopying vhd files. The bytes read/written count matches the vhd file size and robocopy shows 100% but it pauses for several minutes. If I do nothing it will continue, but I will have to wait for quite some time - about the same amount of time as it took to get to 100%. The bytes read/bytes written counters for robocopy do not change. My first thought was that the AV had to scan it, but I'm looking at a machine right now which doesn't have an AV installed and this is occurring, so impossible. No other processes are showing read/write byte counts as going up. The behavior is the same if I use the copy command or xcopy. I've seen this on other systems but have never worked out what the cause is. Anyone got any suggestions as to what might be going on?

    Read the article

  • realtek lan driver problem - win 7

    - by tango _123
    Hi, my new notebook (ACER TM 8371) with Win 7(x32) professional as OS, has strage behaviour with respect to LAN. when I plug or unplug my charger cable, or my notebook goes in stad-by, or just a do nothing, the netwrok connection is lost. All the energy savings functionbality have been in-activated. if i check the network adapter information, it says "a network cabel is unplugged or corrupted", but it is not true.....the cable is in and it is not corrupted (i tried several which works on other machines). if a tried to di-habilitate and hence re-habilitate, it allows di-habilitation and not to further re-habilitate (it says "no driver for the network card" are available). in some cases, also, the driver disappears (i cannot see it anylonger). if i restart the notebook, everything comes back to normality, but.....today in 3 hours i had to restart 6 times!!! can anyone help me? win 7 says the driver is the last one, so no need to update it. here are some techinical information aboiut network card and driver: Name [00000015] Realtek PCIe GBE Family Controller Adapter type Ethernet 802.3 Product type Realtek PCIe GBE Family Controller Installated YES ID device PNP PCI\VEN_10EC&DEV_8168&SUBSYS_02831025&REV_02\4&266E4C4F&0&00E2 last reset 20/11/2009 11:27 Index 15 Service name RTL8167 I/O Port 0x0000FF00-0x0000FFFF Memory address 0xE2500000-0xE2500FFF Memory address 0xE1400000-0xE140FFFF IRQ Channel IRQ 18 Driver c:\windows\system32\drivers\rt86win7.sys (7.3.522.2009, 164,00 KB (167.936 Byte), 28/08/2009 22:12)

    Read the article

  • finding files that match a precise size: a multiple of 4096 bytes

    - by doub1ejack
    I have several drupal sites running on my local machine with WAMP installed (apache 2.2.17, php 5.3.4, and mysql 5.1.53). Whenever I try to visit the administrative page, the php process seems to die. From apache_error.log: [Fri Nov 09 10:43:26 2012] [notice] Parent: child process exited with status 255 -- Restarting. [Fri Nov 09 10:43:26 2012] [notice] Apache/2.2.17 (Win32) PHP/5.3.4 configured -- resuming normal operations [Fri Nov 09 10:43:26 2012] [notice] Server built: Oct 24 2010 13:33:15 [Fri Nov 09 10:43:26 2012] [notice] Parent: Created child process 9924 [Fri Nov 09 10:43:26 2012] [notice] Child 9924: Child process is running [Fri Nov 09 10:43:26 2012] [notice] Child 9924: Acquired the start mutex. [Fri Nov 09 10:43:26 2012] [notice] Child 9924: Starting 64 worker threads. [Fri Nov 09 10:43:26 2012] [notice] Child 9924: Starting thread to listen on port 80. Some research has led me to a php bug report on the '4096 byte bug'. I would like to see if I have any files whose filesize is a multiple of 4096 bytes, but I don't know how to do that. I have gitBash installed and can use most of the typical linux tools through that (find, grep, etc), but I'm not familiar enough with linux to figure it out on my own. Little help?

    Read the article

  • sort utility on cyrillic text

    - by Anton
    I have to sort some lines of cyrillic characters and I want to use the sort utility (on MAC OS X 10.6). The problem is that result is incorrect. I take the text into clipboard, then run pbpaste | sort This is plaintext data, and I also tried passing a file to the sort command. My source data is ??????? ????? ???? ???? ?????? ??????? ???????? ?????? ? ????? ??????????????? ?????????? ???? ?????? And after sorting I get ???? ???? ???? ????? ?????? ?????? ?????? ? ????? ??????????????? ??????? ??????? ???????? ?????????? Theese lines aren’t even grouped by first letter. I tried option -d, but then I get an error sort: string comparison failed: Illegal byte sequence sort: Set LC_ALL='C' to work around the problem. sort: The strings compared were \320\321\321\321' and\320\320\320\321\321\320’. Exporting the variable as recommended doesn’t solve the problem. What can I do to use the sort utility for such a task? Any additional info is necessary?

    Read the article

  • Can not mount my USB disk-- Ubuntu nor windows[dmesg including]

    - by EthanZ6174
    first, here is my dmesn|tail result right after i plugged the disk: $ dmesg | tail [ 2578.697224] scsi 6:0:0:0: Direct-Access HP v100w PMAP PQ: 0 ANSI: 0 CCS [ 2578.698322] sd 6:0:0:0: Attached scsi generic sg2 type 0 [ 2578.916464] sd 6:0:0:0: [sdb] 3921920 512-byte logical blocks: (2.00 GB/1.87 GiB) [ 2578.916950] sd 6:0:0:0: [sdb] Write Protect is off [ 2578.916956] sd 6:0:0:0: [sdb] Mode Sense: 23 00 00 00 [ 2578.916961] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 2578.922460] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 2578.922470] sdb: [ 2578.969570] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 2578.969578] sd 6:0:0:0: [sdb] Attached SCSI removable disk there is nothing after 'sdb:' ... at the meantime, the lsusb shows: $ lsusb Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 004: ID 03f0:3207 Hewlett-Packard Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 006 Device 002: ID 045e:0737 Microsoft Corp. Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 007 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub so... can anyone help me? what's wrong with my USB disk? THX

    Read the article

  • Recover file from NTFS after it was formatted twice

    - by Phil
    I'm running Linux Mint and have a 2TB drive that I formatted as NTFS. I copied ~120GB of files from another computer to the 2TB drive, removing the files from the other computer as I did so. When they were all on the 2TB drive, I zipped them up as file "Gold.tar.gz". Then I reformatted the 2TB drive as ext3 in a moment of absolute stupidity. I formatted the 2TB back to NTFS, but of course everything is gone. Here is what I have tried: TestDisk -- won't find any lost partitions or undelete files, just the current empty one PhotoRec -- seems to only find some broken text files and misidentify their extensions. It never finds the 100's of avi files I had (before the 120GB copy, I already had 750GB on the drive full of avi files) or anything else that would show me it's working properly. Using dd I recovered the first 512MB of the drive and went hunting through it. I found all of the file as MFT entries, including the file "Gold.tar.gz" in a 2048 byte MFT record. I'm looking now for some way of either (1) telling PhotoRec to look at that record, or (2) analyze the MFT record myself and discover the sectors holding the data; I can piece it all together using dd and join the binary output if it's fragmented. One last thing - from the moment I got this drive a few days ago to the incident, there were only file copies made to it and no deletes. I formatted as NTFS, then copied thousands of files, then made a tar.gz, then reformatted to ext3, then reformatted to NTFS again. I'm hoping that the size of the drive and fact that there was no file modification/deleting happening makes for minimal file fragmentation.

    Read the article

  • Why am I unable to mount my USB drive (unknown partition table)?

    - by Pat
    I'm a real newbie to linux. Anyway the problem is that my USB doesn't get recognized anymore which is really annoying because I need information from it. I've read like a zillion threads how to manually mount it but I really can't it to work. I hope it's just some easy, stupid problem where any of you could help me out quickly.. Here is the syslog: kernel: [ 6872.420125] usb 2-2: new high-speed USB device number 11 using ehci_hcd mtp-probe: checking bus 2, device 11: "/sys/devices/pci0000:00/0000:00:1d.7/usb2/2-2" kernel: [ 6872.556295] scsi8 : usb-storage 2-2:1.0 mtp-probe: bus: 2, device: 11 was not an MTP device kernel: [ 6873.558081] scsi 8:0:0:0: Direct-Access SanDisk Cruzer 8.01 PQ: 0 ANSI: 0 CCS kernel: [ 6873.559964] sd 8:0:0:0: Attached scsi generic sg3 type 0 kernel: [ 6873.562833] sd 8:0:0:0: [sdc] 15682559 512-byte logical blocks: (8.02 GB/7.47 GiB) kernel: [ 6873.564867] sd 8:0:0:0: [sdc] Write Protect is off kernel: [ 6873.564878] sd 8:0:0:0: [sdc] Mode Sense: 45 00 00 08 kernel: [ 6873.565485] sd 8:0:0:0: [sdc] No Caching mode page present kernel: [ 6873.565495] sd 8:0:0:0: [sdc] Assuming drive cache: write through kernel: [ 6873.568377] sd 8:0:0:0: [sdc] No Caching mode page present kernel: [ 6873.568387] sd 8:0:0:0: [sdc] Assuming drive cache: write through kernel: [ 6873.574330] sdc: unknown partition table kernel: [ 6873.576853] sd 8:0:0:0: [sdc] No Caching mode page present kernel: [ 6873.576863] sd 8:0:0:0: [sdc] Assuming drive cache: write through kernel: [ 6873.576871] sd 8:0:0:0: [sdc] Attached SCSI removable disk Thanks in advance

    Read the article

  • Read non-blocking from multiple fifos in parallel

    - by Ole Tange
    I sometimes sit with a bunch of output fifos from programs that run in parallel. I would like to merge these fifos. The naïve solution is: cat fifo* > output But this requires the first fifo to complete before reading the first byte from the second fifo, and this will block the parallel running programs. Another way is: (cat fifo1 & cat fifo2 & ... ) > output But this may mix the output thus getting half-lines in output. When reading from multiple fifos, there must be some rules for merging the files. Typically doing it on a line by line basis is enough for me, so I am looking for something that does: parallel_non_blocking_cat fifo* > output which will read from all fifos in parallel and merge the output on with a full line at a time. I can see it is not hard to write that program. All you need to do is: open all fifos do a blocking select on all of them read nonblocking from the fifo which has data into the buffer for that fifo if the buffer contains a full line (or record) then print out the line if all fifos are closed/eof: exit goto 2 So my question is not: can it be done? My question is: Is it done already and can I just install a tool that does this?

    Read the article

  • Sound doesn't work anymore after replacing RAM

    - by thejh
    Hello, today, I replaced one old RAM module with two newer, bigger ones, but now, the sound doesn't seem to work anymore. Already ran alsaconf and it didn't help. Output of lspci for the audio device: 00:07.0 Audio device: nVidia Corporation MCP67 High Definition Audio (rev a1) Subsystem: Giga-byte Technology Device a002 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz+ UDF- FastB2B+ ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 (500ns min, 1250ns max) Interrupt: pin A routed to IRQ 21 Region 0: Memory at f5100000 (32-bit, non-prefetchable) [size=16K] Capabilities: [44] Power Management version 2 Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0-,D1-,D2-,D3hot+,D3cold+) Status: D0 PME-Enable- DSel=0 DScale=0 PME- Capabilities: [50] Message Signalled Interrupts: Mask+ 64bit+ Queue=0/0 Enable- Address: 0000000000000000 Data: 0000 Masking: 00000000 Pending: 00000000 Capabilities: [6c] HyperTransport: MSI Mapping Enable+ Fixed+ Kernel driver in use: HDA Intel Kernel modules: snd-hda-intel The audio device is onboard and has six configurable outputs, two or so are also capable of being an input (if I remember it correctly), but I don't know how to control it under linux. Does somebody know how/whether replacing the RAM could be related to my problem and/or how to fix it?

    Read the article

  • Plesk Uninstall Memory issue

    - by user115079
    I am trying to uninstall plesk from my VPS by running following command: yum remove sw-* psa-* plesk-* when i run this command i get following error: Running rpm_check_debug Running Transaction Test memory alloc (4 bytes) returned NULL. First time when i run above command, this mem alloc (4 bytes) was very big number like (67864987). then i googled it, got some clear/ulimit commands. executed them. rebooted my system. stopped all process and executed this command again. but still getting 4 byte issue. dont know how to get rid of it. I also tried ulimit after reboot but no success and Yes. No swap attached. these are stats of my system [root@vps ~]# free -m total used free shared buffers cached Mem: 384 67 316 0 0 0 -/+ buffers/cache: 67 316 Swap: 0 0 0 top - 21:01:07 up 3:12, 1 user, load average: 0.24, 0.08, 0.03 Tasks: 31 total, 2 running, 29 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 393216k total, 69832k used, 323384k free, 0k buffers Swap: 0k total, 0k used, 0k free, 0k cached is there any other alternative to achieve my goal to uninstall plesk? thanks.

    Read the article

< Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >