  • ProCurve 1800 switch issue

    - by user98651
    I recently deployed ProCurve 1800-24G switches in place of some older ProCurve 2424M switches in my network. However, I'm having a serious problem with the switch connected to the router. It seems, every night when our Windows 2008 R2 server (off site) runs a backup to a iSCSI target (on site) [facilitated through a PPTP tunnel] the LAN loses connectivity with the router. To clarify, there is only one router which is connected to the switch affected by this problem. The only way to resolve the issue is to either reboot the router or pull the ethernet cable that goes to the router and plug it back in. During the outage, clients cannot receive DHCP requests, DNS requests, ping, or do anything else with the router in this state. Now, neither the switch or router are configured extensively and the issue only seems to have surfaced with the new switch in place. I have tried a number of things including replacing cables, rebooting and checking the switch configuration (it is literally as basic as you can get at this point-- flat LAN, no trunking). Interestingly, the router shows (accessed externally) no changes in configuration or status during this state but similarly cannot ping or access other hosts on the network. This issue occurs in different stages of backup (ie, different amounts transferred). I've also dumped packets from the switch into WireShark but cannot seem to find any anomaly yet (I'm looking at packets around the time the issue appeared and at the time when I reset the NIC). Any suggestions for what to look for? Ideas on what could be causing this? I'm seeing some transmit/receive errors on the NIC from both the router and switch side but nothing serious when compared to the total packet counts. I'm seriously doubting hardware at this point, as I have tried another switch, different cables, and a different NIC on the router.

    Read the article

  • Need Routing help (tagged/untagged)

    - by TheCleaner
    I really need some help trying to figure some "basic" routing. My brain is fried from being sick for a week and I'm not thinking clearly. Picture below describes my "setup". I'm trying to accomplish routing a user from their workstation to the Juniper SSG520 and then "OUT" through the internet connection. I can't move the connection as it is physically located where the user's switch is. Here's what I CAN do at this point: I can ping from the Juniper SSG520 eth3/3 to 6x.xxx.253.116 from 6x.xxx.253.114 I can ping from the x450 in the top right to 6x.xxx.253.112 from 6x.xxx.253.116 What I CANNOT DO: I cannot ping from the SSG520 eth3/3 to 6x.xxx.253.112 from 6x.xxx.253.114 (basically from the Juniper box to the gateway. I've tried changing port 1 in the x450 VLAN 666 as tagged but when I do that then I can't even ping from the Juniper SSG520 eth3/3 to the VLAN on the x450 (6x.xxx.253.116). I need to route traffic out the eth3/3 interface on the SSG520 THROUGH the 2 x450 Switches and out the internet connection. The caveat is that the 2 x450 switches are connected via fiber over distance and have tagged VLANs in them for the routing. Thoughts? http://img251.imageshack.us/img251/7752/drawing1.jpg

    Read the article

  • Why does Windows 7 always automatically change the input or keyboard language?

    - by B-Ball
    I am wondering why Windows 7 always automatically changes my input or keyboard language. I've a notebook with an integrated QWERTY keyboard English (United States). Traveling, I use that one but, additionally, I've my own as well as a much better keyboard at home which is a QWERTZ keyboard German (Germany). Thus, being at home, I'd like to use my QWERTZ keyboard. Unfortunately, Windows 7 does not play along at this one. Every time, I start up my notebook, it is usually set to English (United States) but that's not the problem. In case, I'd use my notebook QWERTY keyboard English (United States), that's fine. However, if I start up my notebook and I'd like to use my QWERTZ keyboard German (Germany), I usually press ALT + Left Shift in order to switch from English (United States) to German (Germany) and Windows 7 switches the input language but only for the program that is currently open. If my input language is set to German (Germany) and I, e.g., open NotePad, Windows 7 automatically switches my input language to English (United States). This is very annoying since I've to change the input or keyboard language to German (Germany) every time I open up a new program. Why doesn't Windows 7 stay with one input language if I changed it manually by pressing ALT + Left Shift? Why doesn't the manual change of the input or keyboard language apply for the whole Windows 7? Why does it only affect the currently opened program? Since I've two keyboards with two different layouts, I seriously need to have both of the keyboards languages installed. I tried both of the below settings in order to find a solution for my problem. Currently, I am using the first option, two input languages. First option: two input languages: Second option: two keyboard languages:

    Read the article

  • Slow File Copy observed copying 40GB files across network to iSCSI device

    - by Rick
    Here's a curious ones for the gurus: Setup: Source Machine: Windows Server 2003 R2 machine with local hard drive. VHD file of 40GB. 1 x 1Gbps network card, Cat6 cable, switch. Target Machine: Windows Server 2008 R2 machine with iSCSI connection to iSCSI target on separate machine (1TB, RAID5). 1 x 1Gbps network card, Cat6 cable, connected to same switch as for Source Machine. Second 1Gbps network card, Cat6 cable, connected via isolated switch to the iSCSI target. Switches are Netgear JGS524 model (web managed). If I copy from the Win2003R2 machine to Win2008R2 machine local drive I get 40GB in 45 minutes, 36 seconds. If I copy from the Win2008R2 machine to the iSCSI target (local drive to iSCSI target) I get 40GB in 37 minutes 56 seconds. If I copy from the Win2003R2 machine to the iSCSI target via the Win2008R2 machine I get 40GB in 3 hours, 50 minutes, 24 seconds. All copies were done via the following command issued on the Win2008R2 box: XCOPY <source> <target> /J XCOPY /J - Copies using unbuffered I/O. Recommended for very large files. So, what's the bit I'm missing here? Why does a back-to-back copy take in total 1 hour, 23 minutes, 32 seconds when a "straight through" copy take almost 3 times as long? Switches show no errors, network hovers around the 3% utilisation mark for the duration of the copy (whereas the "back-to-back" copies are around the 25% utilisation mark). What have I missed?

    Read the article

  • Cisco Catalyst 3550 + Alteon 184 Load-Balancing Issues...

    - by upkels
    I have just deployed a couple Cisco Catalyst 3550 switches, and a couple Alteon 184 Web Switches for load-balancing. I can ping all RIPs and VIPs to/from the Alteon. Topology Before: (server) <- (Alteon) <- (Internet) Topology Now: (server) <- (3550) <- Alteon <- (Internet) Cisco Port Configuration (Alteon Uplink Port): description LB_1_PORT_9_PRIMARY switchport access vlan 10 switchport mode access switchport nonegotiate speed 100 duplex full Alteon Port 9 Configuration (VLAN 10 WAN): >> Main# /c/port 9/cur Current Port 9 configuration: enabled pref fast, backup gig, PVID 10, BW Contract 1024 name UPLINK >> Main# /c/port 9/fast/cur Current Port 9 Fast link configuration: speed 100, mode full duplex, fctl none, auto off Cisco Configuration (Load-Balanced Servers Port): description LB_1_PORT_1_PRIMARY switchport access vlan 30 switchport mode access switchport nonegotiate speed 100 duplex full Alteon Port 1 Configuration (VLAN 30 LOAD-BALANCED LAN): >> Main# /c/port 1/cur Current Port 1 configuration: enabled pref fast, backup gig, PVID 30, BW Contract 1024 name LB_PORT_1 >> Main# /c/port 1/fast/cur Current Port 1 Fast link configuration: speed 100, mode full duplex, fctl both, auto on Each of my servers are on vlan 10 and 30, properly communicating. I have tried to turn on VLAN tagging on the Alteon, however it seems to cause all communications to stop working. When I tcpdump -i vlan30 on any of the webservers, I see normal ARP communications, and some STP communications, which may or may not be part of the problem: ... 15:00:51.035882 STP 802.1d, Config, Flags [none], bridge-id 801e.00:11:5c:62:fe:80.8041, length 42 15:00:51.493154 IP 10.1.1.254.33923 > 10.1.1.1.http: Flags [S], seq 707324510, win 8760, options [mss 1460], length 0 15:00:51.493336 IP 10.1.1.1.http > 10.1.1.254.33923: Flags [S.], seq 3981707623, ack 707324511, win 65535, options [mss 1460], len gth 0 15:00:51.493778 ARP, Request who-has 10.1.3.1 tell 10.1.3.254, length 46 etc... I'm not sure if I've provided enough information, so please let me know if any more is necessary. Thank you!

    Read the article

  • Ruckus wireless AP and Dell PowerConnect configuration problems

    - by DanielJay
    We are working on trying to get some Ruckus Access Points to work correctly on our network. Currently our network is as follows: VLAN 10 - Servers VLAN 11 – Computers/DHCP VLAN 12 – Voice VLAN 13 – Guest We use Dell PowerConnect 6248P switches for our switches. Port settings are as follows: ZoneDirector 1100 is plugged into this port. Should be accessing the server VLAN and then allowing all other traffic. interface ethernet 1/g2 classofservice trust ip-dscp description 'Ruckus ZoneDirector 1100' switchport mode general switchport general pvid 10 switchport general allowed vlan add 10 switchport general allowed vlan add 11-13 tagged exit Access point is plugged into this port. The port has to be on VLAN 11 in order to get DHCP. interface ethernet 1/g16 classofservice trust ip-dscp description 'Ruckus - IT' switchport mode general switchport general pvid 11 switchport general allowed vlan add 10-12 switchport general allowed vlan add 13 tagged exit If we tag the traffic from the SSID as VLAN 11 data fails. If we leave the SSID tagged as 1 the data flows correctly. Are there problems with passing tagged traffic to untagged ports? We are looking to see what we can do to get the SSID tagged as 11 instead of 1. Any suggestions?

    Read the article

  • VGA to S-Video/Video converter showing mashed up picture.

    - by Matthijs Wessels
    Earlier I asked this question: *http://superuser.com/questions/132374/does-the-lenovo-t60p-vga-port-support-an-s-video-signal As a result I acquired the following item: http://cgi.ebay.nl/ws/eBayISAPI.dll?ViewItem&item=250588098582&ssPageName=ADME:B:EOIBSA:NL:1123 Yea I'm a cheapass... Anyway, it just arrived and now I am trying to get it to work... The manual is not very informative other than telling me, this is the vga in, this is the vga out, this is the s/video out etc. Plus it tells me the system should support the following resolutions@refresh rate: 640x480@60/72/75Hz 800x600@60/75Hz 1024x768@60Hz I can connect it to my laptop and then I connect the S/Video and the Video to my tv which only gives me a blurred image (like when you set your monitor to a resolution it doesn't support). The VGA out however works fine to my tft monitor. The are two switches on the converter. I think one switches between s/video and video and the other between PAL and NTSC. But alas, no combination seems to give a better picture (it does give a different picture). Can anyone help me to solve this problem? I have downloaded this program called powerstrip, but I have no idea how to use it and if it can even solve my problem... Thanks in advance. I use Windows XP on a Lenovo t60p and I try to connect it to a Philips 32PFL7403D/12 LCD TV from VGA to a converter to S-video or video.

    Read the article

  • Intermittently uncommunicative subnets

    - by mhd
    Last week proved me a veritable Cassandra: I've always said that it's a bad idea to have only one firewall/router, without a backup or failover. And thus our Cisco PIX went haywire, refusing to route properly. And of course, the only one available here on short notice is me, and while I'm quite grounded in Linux, I'm really a developer not a sysadmin (the fact that this hit me on sysadmin appreciation day is a bit ironic). Anyway, this weekend I tried to hack up a temporary solution: I used an old server with enough NICs (two built-in, four on a card) to serve as a gateway and firewall. Due to some problems with the raid controller, I got only two router distros running, and between Untangle and Ebox I decided for the latter. Now everything is quite okay. I've got all the different subnets we've got here (all with separate switches) talking to each other and even to the internet (Cisco 2800 router, T1 lines). But from time to time (20-60 minute intervals), I get a total routing failure. Our main, office subnet can't talk to our server subnet and can't connect to the internet. This is not the end of a gradual slowdown, either everything's working perfectly or I get a total lack of communication for about two minutes each time. Now I'm a bit at wits end what to check. At least with the default EBox setup, nothing in /var/log shows anything weird and it doesn't exactly have lots of built-in monitoring tools. So I'm hoping someone here could give me some pointers about what to look out for. I did change the ethernet cable from the office switch to the firewall, with no results. I might change switches, although within the switch it seems to work ok enough. Edit: I'm not sure whether this is the sole cause of the problem, but after I noticed a few DHCP entries just before the last drop of connectivity, I tried to reproduce that. And alas, whenever I renew a DHCP connection, I can't access other subnets anymore. Running ISC DHCPD 3.0.6.

    Read the article

  • Hyper-V with multiple physical networks

    - by Yaman
    I have Hyper-V on my laptop with a wireless and Ethernet card, sometimes I connect using wireless card, and sometimes using the Ethernet cable. I am trying to configure Hyper-v to work always with internet provided to virtual machine. I have tried to create 2 virtual switches, one external to the Wireless network card, and the other one external to the Ethernet card. What happens is that the wireless network creates a bridge object in the network and sharing center\Network connections of windows 8, while the Ethernet does not. Unfortunately, they do not work together as external, i have to set the connected one to external and the other one as external, I also have to go to the properties of the bridge and virtual Ethernet properties to uncheck and check some components like: Client for Microsoft Networks Deterministic Network Enhancer VMWare Bridge Protocol QoS Packet Scheduler File and Printer Sharing for Microsoft Networks In order to make things work. Sometimes I keep the wireless network switch external, and go to another location (another wireless network), and it disconnects, i have to reconfigure the switches. Is there a way to do the configuration once and remain working wherever I connect, whether its Wireless or Ethernet and on any network with DHCP?

    Read the article

  • Cisco Catalyst 3550 + Alteon 184 Load-Balancing Issues

    - by upkels
    I have just deployed a couple Cisco Catalyst 3550 switches, and a couple Alteon 184 Web Switches for load-balancing. I can ping all RIPs and VIPs to/from the Alteon. Topology Before: (server) <- (Alteon) <- (Internet) Topology Now: (server) <- (3550) <- Alteon <- (Internet) Cisco Port Configuration (Alteon Uplink Port): description LB_1_PORT_9_PRIMARY switchport access vlan 10 switchport mode access switchport nonegotiate speed 100 duplex full Alteon Port 9 Configuration (VLAN 10 WAN): >> Main# /c/port 9/cur Current Port 9 configuration: enabled pref fast, backup gig, PVID 10, BW Contract 1024 name UPLINK >> Main# /c/port 9/fast/cur Current Port 9 Fast link configuration: speed 100, mode full duplex, fctl none, auto off Cisco Configuration (Load-Balanced Servers Port): description LB_1_PORT_1_PRIMARY switchport access vlan 30 switchport mode access switchport nonegotiate speed 100 duplex full Alteon Port 1 Configuration (VLAN 30 LOAD-BALANCED LAN): >> Main# /c/port 1/cur Current Port 1 configuration: enabled pref fast, backup gig, PVID 30, BW Contract 1024 name LB_PORT_1 >> Main# /c/port 1/fast/cur Current Port 1 Fast link configuration: speed 100, mode full duplex, fctl both, auto on Each of my servers are on vlan 10 and 30, properly communicating. I have tried to turn on VLAN tagging on the Alteon, however it seems to cause all communications to stop working. When I tcpdump -i vlan30 on any of the webservers, I see normal ARP communications, and some STP communications, which may or may not be part of the problem: ... 15:00:51.035882 STP 802.1d, Config, Flags [none], bridge-id 801e.00:11:5c:62:fe:80.8041, length 42 15:00:51.493154 IP 10.1.1.254.33923 > 10.1.1.1.http: Flags [S], seq 707324510, win 8760, options [mss 1460], length 0 15:00:51.493336 IP 10.1.1.1.http > 10.1.1.254.33923: Flags [S.], seq 3981707623, ack 707324511, win 65535, options [mss 1460], len gth 0 15:00:51.493778 ARP, Request who-has 10.1.3.1 tell 10.1.3.254, length 46 etc... I'm not sure if I've provided enough information, so please let me know if any more is necessary. Thank you!

    Read the article

  • How to configure network on Windows Server 2008

    - by Gokhan Ozturk
    I have a IBM x3400 Server Machine with Windows Server 2008 R2 installed on it. But, since I am not expert on networking I have some problems. These roles installed on my server: Active Directory DNS File Sharing Hyper-V ISS VPN There is two network card on them. I configured them like this: Local Connection 1: 192.168.30.3 255.255.255.0 192.168.30.2 127.0.0.1 Local Connection 2: 192.168.30.101 255.255.255.0 192.168.30.6 127.0.0.1 My problem is, when I use this Ip gateways, It is sharing internet to all computers. This is not I want. I want to use Local Connection 1 for internal network. I am giving all computers gateway and DNS IP as 192.168.30.3 The Local Connection 2 is for Hyper-V and VPN connections. 192.168.30.2 and 192.168.30.6 are my modem's gateways. I am using 192.168.30.6 external IP for VPN connections. There is two 24 port switches. There is a connection between them and this two ethernet card connected directly to them. And modems are connected to switches as well (Morems are not near the server. They are somewhere in the building). I disabled network Bridge and removed all ethernet cards from it. With this configuration, all computers can ping my server's IP (192.168.30.3) but on server I cannot ping any clients (Request timeout). What is the best way to configure my network? Thank you. Redgards

    Read the article

  • Ignore non-unicode programs language when installing software

    - by mitya
    This is something that is driving me nuts for a while and I haven't been able to find a solution for this problem anywhere. I am running Windows 7 and my "Language for non-Unicode programs" setting is set to Russian. I need for some non-unicode software that has a Russian UI. However, for most of my software I prefer to use the English UI. A lot of software out there is multilingual and is too smart for my liking. When installing, it switches the UI to Russian and the software UI stays in Russian after the installation without an option to change that, besides setting the "non-unicode language" to English. It switches back to Russian once I revert the setting and reboot. Most of the time it is driver software, i.e: Intel, HP, etc. How can force the installation to run English and stay that way after install, ignoring the "Language for non-Unicode programs" setting? Now, I understand this might be specific to the installer: MSI, Install Shield, etc. But any solution will be good, even if I have to apply it for every software installation. Thanks in advance for any helpful information!

    Read the article

  • What could be wrong with my VLAN?

    - by Matt
    I've got a VLAN 10 setup as a management VLAN. The management VLAN comes off port 48 and links to another set of switches that do not support VLAN's so it was I believe set up as an untagged access port. In the past this was a different brand of switch and this worked fine. However, since changing to the HP V1910-48G series I can't seem to get this working. I must point out that as far as I'm aware it is wired up properly (I can't check this physically as I'm working remote and have asked the tech who's got access to double check for me). Now I don't have a huge amount of experience with VLAN environments but AFAIK this is right. I've set the port 48 (linked to the management switches) as an untagged port with PVID 10 and access link type. Is this all I'd need to do from a configuration perspective to ensure all devices connected to port 48 would end up being on VLAN 10 and not needing to tag their frames. i.e. the tag would be added by the switch before being forwarded.

    Read the article

  • moving files and directories between two machine, via a third, preserving permissions and usernames

    - by Jarmund
    The situation is as follows: Machine A has a file repository accessible via rsync Machine B needs the above mentioned files with all permissions and ownerships intact (including groups etc) Machine C has access to both A and B, but has a completely different set of users. Normally, i would just rsync everything over, directly between A and B, but due to severely limited bandwidth at the moment, i need something different, as rsync times out after building the list of the 430 files (49Mb uncompressed... can be compressed down to ~7Mb). What i've tried so far: rsync everything over from A to C, tar it, copy the tarball over, and then untar it, however, this messes up the ownership and/or the permissions. To rsync it from A to C, i run this command: rsync --numeric-ids --password-file=/root/rsync_pwd_file -oaPvu rsync://[email protected]/portal_2/ ./portal_2/ ...and from the looks of things, they do end up on C with the correct ownerships/permissions/flags/everything (not 100% sure, though.. are there any more switches i can throw in there? did i miss something?) copying the tarball over is simple enough (slow as a one-legged turtle due to the bandwidth, but it checksums out alright) What i'm unsure of is the flags and switches for creating and extracting the tarball, so could someone please provide the full commands for creating a tarball from /root/portal_2 on machine C (with everything intact) and extracting the tarball into /var/ex/portal_2 on machine B? ? Also, are there any other approaches worth mentioning that could allow me to perform this? I have root access to A and C, whereas i only have rsync access to B. PS: I'm running rsync v2.6.9 on machine B, and unfortunately i do not have the oportunity to upgrade to v3

    Read the article

  • Viability of Mac OS X 10.9 Time Machine Server in office environment

    - by user197609
    Currently we have about 20 Mac OS 10.9 MacBook Pros (almost all with SSDs) backing up to individual USB drives. I'd like to consolidate these to one drobo thunderbolt drive array attached to a Mac Mini server (running 10.9 server) using time machine server. My question is, will this scale to 20 users? Examples I have seen seem to be 5 or 6 users tops, and this isn't easy for me to test (I'd rather not ask everyone to backup to the array and then switch back to USB drives if it brings our network to its knees). My primary concern is saturating our gigabit network, as time machine backs up every hour for every machine, so there would usually be a couple people backing up at any given time. We also have some people occasionally on our 802.11ac network and not on ethernet (usually connected via 802.11n until people upgrade to newer machines), but most of the time people are connected to our thunderbolt displays which have a gigabit ethernet connection on them. Our network topology is one 32 port gigabit switch with 5 smaller gigabit switches at each desk cluster. The mac mini server is connected directly to the top level switch. Update: Failing information from someone who has done this in practice, I suppose my question is really around how switches work. If three or four people are backing up simultaneously, and then other two (different) users transfer a file between each other, will they be able to transfer the file at gigabit speeds?

    Read the article

  • Locate devices within a building

    - by ams0
    The situation: Our company is spread between two floors in a building. Every employee has a laptop (macbook Air or MacbookPro) and an iPhone. We have static DHCP mappings and DNS resolution so every mobile gets a name like employeeiphone.example.com, every macbook air gets a employeelaptop.example.com and every macbook pro gets a employeelaptop.example.com on the Ethernet interface (the wifi gets a dynamic IP from a small range dedicated for the purpose). We know each and every MAC address of phones and laptops, since we do DHCP static mapping (ISC DHCP server runs on linux). At each floor we have a Netgear stack of two switches, connected via 10GB fiber to each other. No VLANs so far. At every floor there are 4 Airport Extreme making a single SSID network with WPA2 authentication. The request: Our CTO wants to know who is present at which floor. My solution (so far): Every switch contains an table listing MAC address and originating port. On each switch stack, all the MAC addresses coming from the other floor are listed as coming on port 48 (the fiber link). So I came up with: 1) Get the table from each switch via SNMP 2) Filter out the ones associated with port 48 3) Grep dhcpd.conf, removing all entries not *laptop and not *iphone 4) Match the two lists for each switch, output in JSON or XML 5) present the results on a dashboard for all to see I wrote it in bash with a lot of awk and sed, it kinda works but I always have for some reason stale entries in the switch lookup tables, making it unreliable; some people may have put their laptop to sleep, their iphones drop connections after a while, if not woken up and so on..I searched left and right, we are prepared to spend a little on the project too (RFIDs?), does anybody do something similar? I can provide with the script if needed (although it's really specific to our switches and naming scheme). Thanks! p.s. perhaps is this a question for stackoverflow? please move if it so.

    Read the article

  • Need solution for Network/Servers.

    - by rehanplus
    Dear All, Please help me. I just joined a new Hospital and want some help managing my network. There are some requirements: Current Network: There is a D.S.L connection and that is terminated on a LINUX proxy and then connected to D-Link layer 2 switches and then providing internet to more then 200 PC's (Would be increasing to 1500 in couple of months). D-Link switches are not configured yet. Also there is one Database server Report server and an application server. In near Future Application should be accessed by local users as well as remote users from internet via our web server. We do have a sharing server and all these servers databases and PC's are on single sub net. Required Network: All i do want is to secure my network from outside access and just allowing specific users via web application and they will be submitting there record for patient card and appointment facility by means of application and entering there record (on our database) but not violating our network resources. Secondly in house users also need to access the same application and also internet but they must have some unique identity and rights (i.e. Finance lab dept. peoples do have limited access to that application). Notes: Should i create V LAN or break sub nets. Having a firewall will solve my issues? is a router needed on these type of scenario's. Currently all the access are restricted from Linux Proxy. Thanks.

    Read the article

  • Would a USB hub work in reverse?

    - by Tim
    Imagine for a moment with a 4 port USB hub. Normally how this would work is the hub has one plug that goes to the computer, then 4 ports that you can plug in other things to (thumb drive, keyboard, mouse etc). I am wondering if I can use it in reverse. So I would have 1 keyboard going in to the hub, and then plug in male to male usb cables from the 4 ports to 4 different PCs, my aim is that when a key is pressed on the keyboard all 4 PCs will receive it as if the keyboard were plugged in to them. Does anyone know if this would work? And if not does anyone have any ideas how I could get the same effect? EDIT: So I am looking for more of a KVM switch type device rather than a USB hub. However all of the KVM switches I've found use some sort of mechanism to select which computer you'll be using. (some are physical switches / buttons, others do it via software "automatically" some how) However I need to have 1 keyboard hooked up to 2 computers and when I press a key on the keyboard I want the keypress to be sent to both computers simultaneously, not to one or the other. Does anyone know if KVMs with this feature exist?

    Read the article

  • Microbenchmark showing process-switching faster than thread-switching; what's wrong?

    - by Yang
    I have two simple microbenchmarks trying to measure thread- and process-switching overheads, but the process-switching overhead. The code is living here, and r1667 is pasted below: https://assorted.svn.sourceforge.net/svnroot/assorted/sandbox/trunk/src/c/process_switch_bench.c // on zs, ~2.1-2.4us/switch #include <stdlib.h> #include <fcntl.h> #include <stdint.h> #include <stdio.h> #include <semaphore.h> #include <unistd.h> #include <sys/wait.h> #include <sys/types.h> #include <sys/time.h> #include <pthread.h> uint32_t COUNTER; pthread_mutex_t LOCK; pthread_mutex_t START; sem_t *s0, *s1, *s2; void * threads ( void * unused ) { // Wait till we may fire away sem_wait(s2); for (;;) { pthread_mutex_lock(&LOCK); pthread_mutex_unlock(&LOCK); COUNTER++; sem_post(s0); sem_wait(s1); } return 0; } int64_t timeInMS () { struct timeval t; gettimeofday(&t, NULL); return ( (int64_t)t.tv_sec * 1000 + (int64_t)t.tv_usec / 1000 ); } int main ( int argc, char ** argv ) { int64_t start; pthread_t t1; pthread_mutex_init(&LOCK, NULL); COUNTER = 0; s0 = sem_open("/s0", O_CREAT, 0022, 0); if (s0 == 0) { perror("sem_open"); exit(1); } s1 = sem_open("/s1", O_CREAT, 0022, 0); if (s1 == 0) { perror("sem_open"); exit(1); } s2 = sem_open("/s2", O_CREAT, 0022, 0); if (s2 == 0) { perror("sem_open"); exit(1); } int x, y, z; sem_getvalue(s0, &x); sem_getvalue(s1, &y); sem_getvalue(s2, &z); printf("%d %d %d\n", x, y, z); pid_t pid = fork(); if (pid) { pthread_create(&t1, NULL, threads, NULL); pthread_detach(t1); // Get start time and fire away start = timeInMS(); sem_post(s2); sem_post(s2); // Wait for about a second sleep(1); // Stop thread pthread_mutex_lock(&LOCK); // Find out how much time has really passed. sleep won't guarantee me that // I sleep exactly one second, I might sleep longer since even after being // woken up, it can take some time before I gain back CPU time. Further // some more time might have passed before I obtained the lock! int64_t time = timeInMS() - start; // Correct the number of thread switches accordingly COUNTER = (uint32_t)(((uint64_t)COUNTER * 2 * 1000) / time); printf("Number of process switches in about one second was %u\n", COUNTER); printf("roughly %f microseconds per switch\n", 1000000.0 / COUNTER); // clean up kill(pid, 9); wait(0); sem_close(s0); sem_close(s1); sem_unlink("/s0"); sem_unlink("/s1"); sem_unlink("/s2"); } else { if (1) { sem_t *t = s0; s0 = s1; s1 = t; } threads(0); // never return } return 0; } https://assorted.svn.sourceforge.net/svnroot/assorted/sandbox/trunk/src/c/thread_switch_bench.c // From <http://stackoverflow.com/questions/304752/how-to-estimate-the-thread-context-switching-overhead> // on zs, ~4-5us/switch; tried making COUNTER updated only by one thread, but no difference #include <stdlib.h> #include <stdint.h> #include <stdio.h> #include <pthread.h> #include <unistd.h> #include <sys/time.h> uint32_t COUNTER; pthread_mutex_t LOCK; pthread_mutex_t START; pthread_cond_t CONDITION; void * threads ( void * unused ) { // Wait till we may fire away pthread_mutex_lock(&START); pthread_mutex_unlock(&START); int first=1; pthread_mutex_lock(&LOCK); // If I'm not the first thread, the other thread is already waiting on // the condition, thus Ihave to wake it up first, otherwise we'll deadlock if (COUNTER > 0) { pthread_cond_signal(&CONDITION); first=0; } for (;;) { if (first) COUNTER++; pthread_cond_wait(&CONDITION, &LOCK); // Always wake up the other thread before processing. The other // thread will not be able to do anything as long as I don't go // back to sleep first. pthread_cond_signal(&CONDITION); } pthread_mutex_unlock(&LOCK); return 0; } int64_t timeInMS () { struct timeval t; gettimeofday(&t, NULL); return ( (int64_t)t.tv_sec * 1000 + (int64_t)t.tv_usec / 1000 ); } int main ( int argc, char ** argv ) { int64_t start; pthread_t t1; pthread_t t2; pthread_mutex_init(&LOCK, NULL); pthread_mutex_init(&START, NULL); pthread_cond_init(&CONDITION, NULL); pthread_mutex_lock(&START); COUNTER = 0; pthread_create(&t1, NULL, threads, NULL); pthread_create(&t2, NULL, threads, NULL); pthread_detach(t1); pthread_detach(t2); // Get start time and fire away start = timeInMS(); pthread_mutex_unlock(&START); // Wait for about a second sleep(1); // Stop both threads pthread_mutex_lock(&LOCK); // Find out how much time has really passed. sleep won't guarantee me that // I sleep exactly one second, I might sleep longer since even after being // woken up, it can take some time before I gain back CPU time. Further // some more time might have passed before I obtained the lock! int64_t time = timeInMS() - start; // Correct the number of thread switches accordingly COUNTER = (uint32_t)(((uint64_t)COUNTER * 2 * 1000) / time); printf("Number of thread switches in about one second was %u\n", COUNTER); printf("roughly %f microseconds per switch\n", 1000000.0 / COUNTER); return 0; }

    Read the article

  • Poor home office network performance and cannot figure out where the issue is

    - by Jeff Willener
    This is the most bizarre issue. I have worked with small to mid size networks for quite a long time and can say I'm comfortable connecting hardware. Where you will start to lose me is with managed switches and firewalls. To start, let me describe my network (sigh, shouldn't but I MUST solve this). 1) Comcast Cable Internet 2) Motorola SURFboard eXtreme Cable Modem. a) Model: SB6120 b) DOCSIS 3.0 and 2.0 support c) IPv4 and IPv6 support 3-A) Cisco Small Business RV220W Wireless N Firewall a) Latest firmware b) Model: RV220W-A-K9-NA c) WAN Port to Modem (2) d) vlan 1: work e) vlan 2: everything else. 3-B) D-Link DIR-615 Draft 802.11 N Wireless Router a) Latest firmware b) WAN Port to Modem (2) 4) Servers connected directly to firewall a) If firewall 3-A, then vlan 1 b) CAT5e patch cables c) Dell PowerEdge 1400SC w/ 10/100 integrated NIC (Domain Controller, DNS, former DHCP) d) Dell PowerEdge 400SC w/ 10/100/1000 integrated NIC (VMWare Server) 4) Linksys EZXS88W unmanaged Workgroup 10/100 Switch a) If firewall 3-A, then vlan 2 b) 25' CAT5e patch cable to firewall (3-A or 3-B) c) Connects xBox 360, Blu-Ray player, PC at TV 5) Office equipment connected directly to firewall a) If firewall 3-A, then vlan 1 b) ~80' CAT6 or CAT5e patch cable to firewall (3-A or 3-B) c) Connects 1) Dell Latitude laptop 10/100/1000 2) Dell Inspiron laptop 10/100 3) Dell Workstation 10/100/1000 (Pristine host, VMWare Workstation 7.x with many bridged VM's) 4) Brother Laser Printer 10/100 5) Epson All-In-One Workforce 310 10/100 5-A) NetGear FS116 unmanaged 10/100 switch a) I've had this switch for a long time and never had issues. 5-B) NetGear GS108 unmanaged 10/100/1000 switch a) Bought new for this issue and returned. 5-C) Linksys SE2500 unmanaged 10/100/1000 switch a) Bought new for this issue and returned. 5-D) TP-Link TL-SG10008D unmanaged 10/100/1000 a) Bought new for this issue and still have. 6) VLan 1 Wireless Connections (on same subnet if 3-B) a) Any of those at 5c b) HP Laptop 7) VLan 2 Wireless Connection (on same subnet if 3-B) a) IPad, IPod b) Compaq Laptop c) Epson Wireless Printer Shew, without hosting a diagram I hope that paints a good picture. The Issue The breakdown here is at item 5. No matter what I do I cannot have a switch at 5 and have to run everything wireless regardless of router. Issues related to using a switch (point 5 above) SpeedTest is good. Poor throughput to other devices if can communicate at all. Usually cannot ping other devices even on the same switch although, when able, ping times are good. Eventual lose of connectivity and can "sometimes" be restored by unplugging everything for several days, not minutes or hours but we're talking a week if at all. Directly connect to computer gives good internet connection however throughput to other devices connected to firewall is at best horrible. Yet printing doesn't seem to be an issue as long as they are connected via wireless. I have to force the RV220W to 1000Mb on the respective port if using a Gig Switch Issues related to using wireless in place of a switch (point 5 above) Poor throughput to other devices if can communicate. SpeedTest is good. Bottom line Internet speeds are awesome. By the way, Comcast went WAY above and beyond to make sure it was not them. They rewired EVERYTHING which did solve internet drops. Computer to computer connections are garbage Cannot get switch at 5 to work, yet other at 4 has never had an issue. Direct connection, bypass switch, is good for DHCP and internet. DNS must be on server, not firewall. Cisco insists its my switches but as you can see I have used four and two different cables with the same result. My gut feeling is something is happening with routing. But I'm not smart enough to know that answer. I run a lot of VM's at 5-c-3, could that cause it? What's different compared to my previous house is I have introduced Gigabit hardware (firewall/switches/computers). Some of my computers might have IPv6 turned on if I haven't turned it off already. I'm truly at a loss and hope anyone has some crazy idea how to solve this. Bottom line, I need a switch in my office behind the firewall. I've changed everything. The real crux is I will find a working solution and, again, after days it will stop working. So this means I cannot isolate if its a computer since I have to use them. Oh and a solution is not throwing more money at this. I'm well into $1k already. Yah, lame.

    Read the article

  • Load-balancing between a Procurve switch and a server

    - by vlad
    Hello I've been searching around the web for this problem i've been having. It's similar in a way to this question: How exactly & specifically does layer 3 LACP destination address hashing work? My setup is as follows: I have a central switch, a Procurve 2510G-24, image version Y.11.16. It's the center of a star topology, there are four switches connected to it via a single gigabit link. Those switches service the users. On the central switch, I have a server with two gigabit interfaces that I want to bond together in order to achieve higher throughput, and two other servers that have single gigabit connections to the switch. The topology looks as follows: sw1 sw2 sw3 sw4 | | | | --------------------- | sw0 | --------------------- || | | srv1 srv2 srv3 The servers were running FreeBSD 8.1. On srv1 I set up a lagg interface using the lacp protocol, and on the switch I set up a trunk for the two ports using lacp as well. The switch showed that the server was a lacp partner, I could ping the server from another computer, and the server could ping other computers. If I unplugged one of the cables, the connection would keep working, so everything looked fine. Until I tested throughput. There was only one link used between srv1 and sw0. All testing was conducted with iperf, and load distribution was checked with systat -ifstat. I was looking to test the load balancing for both receive and send operations, as I want this server to be a file server. There were therefore two scenarios: iperf -s on srv1 and iperf -c on the other servers iperf -s on the other servers and iperf -c on srv1 connected to all the other servers. Every time only one link was used. If one cable was unplugged, the connections would keep going. However, once the cable was plugged back in, the load was not distributed. Each and every server is able to fill the gigabit link. In one-to-one test scenarios, iperf was reporting around 940Mbps. The CPU usage was around 20%, which means that the servers could withstand a doubling of the throughput. srv1 is a dell poweredge sc1425 with onboard intel 82541GI nics (em driver on freebsd). After troubleshooting a previous problem with vlan tagging on top of a lagg interface, it turned out that the em could not support this. So I figured that maybe something else is wrong with the em drivers and / or lagg stack, so I started up backtrack 4r2 on this same server. So srv1 now uses linux kernel 2.6.35.8. I set up a bonding interface bond0. The kernel module was loaded with option mode=4 in order to get lacp. The switch was happy with the link, I could ping to and from the server. I could even put vlans on top of the bonding interface. However, only half the problem was solved: if I used srv1 as a client to the other servers, iperf was reporting around 940Mbps for each connection, and bwm-ng showed, of course, a nice distribution of the load between the two nics; if I run the iperf server on srv1 and tried to connect with the other servers, there was no load balancing. I thought that maybe I was out of luck and the hashes for the two mac addresses of the clients were the same, so I brought in two new servers and tested with the four of them at the same time, and still nothing changed. I tried disabling and reenabling one of the links, and all that happened was the traffic switched from one link to the other and back to the first again. I also tried setting the trunk to "plain trunk mode" on the switch, and experimented with other bonding modes (roundrobin, xor, alb, tlb) but I never saw any traffic distribution. One interesting thing, though: one of the four switches is a Cisco 2950, image version 12.1(22)EA7. It has 48 10/100 ports and 2 gigabit uplinks. I have a server (call it srv4) with a 4 channel trunk connected to it (4x100), FreeBSD 8.0 release. The switch is connected to sw0 via gigabit. If I set up an iperf server on one of the servers connected to sw0 and a client on srv4, ALL 4 links are used, and iperf reports around 330Mbps. systat -ifstat shows all four interfaces are used. The cisco port-channel uses src-mac to balance the load. The HP should use both the source and destination according to the manual, so it should work as well. Could this mean there is some bug in the HP firmware? Am I doing something wrong?

    Read the article

  • How to resolve CGDirectDisplayID changing issues on newer multi-GPU Apple laptops in Core Foundation

    - by Dave Gallagher
    In Mac OS X, every display gets a unique CGDirectDisplayID number assigned to it. You can use CGGetActiveDisplayList() or [NSScreen screens] to access them, among others. Per Apple's docs: A display ID can persist across processes and system reboot, and typically remains constant as long as certain display parameters do not change. On newer mid-2010 MacBook Pro's, Apple started using auto-switching Intel/nVidia graphics. Laptops have two GPU's, a low-powered Intel, and a high-powered nVidia. Previous dual-GPU laptops (2009 models) didn't have auto-GPU switching, and required the user to make a settings change, logoff, and then logon again to make a GPU switch occur. Even older systems only had one GPU. There's an issue with the mid-2010 models where CGDirectDisplayID's don't remain the same when a display switches from one GPU to the next. For example: Laptop powers on. Built-In LCD Screen is driven by Intel chipset. Display ID: 30002 External Display is plugged in. Built-In LCD Screen switches to nVidia chipset. It's display ID changes: 30004 External Display is driven by nVidia chipset. ...at this point, the Intel chipset is dormant... User unplugs External Display. Built-In LCD Screen switches back to Intel chipset. It's display ID changes back to original: 30002 My question is, how can I match an old display ID to a new display ID when they alter due to a GPU change? Thought about: I've noticed that the display ID only changes by 2, but I don't have enough test Mac's available to determine if this is common to all new MacBook Pro's, or just mine. Kind of a kludge if "just check for display ID's which are +/-2 from one another" works, anyway. Tried: CGDisplayRegisterReconfigurationCallback(), which notifies before-and-after when displays are going to change, has no matching logic. Putting something like this inside a method registered with it doesn't work: // Run before display settings change: CGDirectDisplayID directDisplayID = ...; io_service_t servicePort = CGDisplayIOServicePort(directDisplayID); CFDictionaryRef oldInfoDict = IODisplayCreateInfoDictionary(servicePort, kIODisplayMatchingInfo); // ...display settings change... // Run after display settings change: CGDirectDisplayID directDisplayID = ...; io_service_t servicePort = CGDisplayIOServicePort(directDisplayID); CFDictionaryRef newInfoDict = IODisplayCreateInfoDictionary(servicePort, kIODisplayMatchingInfo); BOOL match = IODisplayMatchDictionaries(oldInfoDict, newInfoDict, 0); if (match) NSLog(@"Displays are a match"); else NSLog(@"Displays are not a match"); What's happening above is I'm caching oldInfoDict before display settings change, letting them change, and then comparing it to newInfoDict by using IODisplayMatchDictionaries(), which will say either "yes, both displays are the same!" or "no, both displays are not the same." Unfortunately, it does not return YES if GPU's have changed for a monitor. Example of the dictionary's it's comparing: // oldInfoDict (Display ID: 30002) oldInfoDict: { DisplayProductID = 40144; DisplayVendorID = 1552; IODisplayLocation = "IOService:/AppleACPIPlatformExpert/PCI0@0/AppleACPIPCI/IGPU@2/AppleIntelFramebuffer/display0/AppleBacklightDisplay"; } // newInfoDict (Display ID: 30004) newInfoDict: { DisplayProductID = 40144; DisplayVendorID = 1552; IODisplayLocation = "IOService:/AppleACPIPlatformExpert/PCI0@0/AppleACPIPCI/P0P2@1/IOPCI2PCIBridge/GFX0@0/NVDA,Display-A@0/NVDA/display0/AppleBacklightDisplay"; } As you can see, the IODisplayLocation key changes when GPU's are switched, hence IODisplayMatchDictionaries() doesn't work. I can, theoretically, compared just the DisplayProductID and DisplayVendorID keys, but I'm writing end-user software, and am worried of a situation where users have two or more identical monitors plugged in. Any help is greatly appreciated! :)

    Read the article

  • A view interface for large object/array dumps

    - by user685107
    I want to embed in a page a detailed structure report of my model objects, like print_r() or var_export() produce (now I’m doing this with running var_export() on get_object_vars()). But what I actually want to see is only some properties (in most cases), but at this moment I have to use Ctrl+F and seek the variable I want, instead of just staring at it right after the page completes loading. So I’m embedding buttons to show/hide large arrays etc. but thought: ‘What if there already is the thing I do right now?’ So is there? Update: What would your ideal interface look like? First of all, dumped models fit in the first screen. All the properties can be seen at the first look at the screen (there are not many of them, around 10 per each, three models total, so it is possible). Small arrays can be shown unrolled too. Let the size of the array to count it as ‘small’ be definable. Ideally, the user can see values of the properties without doing any click, scrolling the screen or typing something. There must be some improvements to representing the values, say, if an array is empty, show array ‘My_big_array’ is empty and if a boolean variable starting with is_, has_, had_ has a false as the value, make the variable (let us take is_available for example) shown as is_NOT_available in red, and if it has true as the value, show is_available in green. Without any value shown. The same goes for defined constants. That would be ideal. I want to make focus on this kind of switches. Krumo seems useful, but since it always closes up the variable without making difference of how large it is, I cannot use it as is, but there might appear something similar on github soon :) Second update starts here: Any programmer who sees is_available = false will know what it means, no need to do more Bringing in color indication I forgot about one thing: the ‘switches’ let’s call them so, may me important or not. So I have right now some of them that will show in green or red, this is for something global, like caching, which is shown as Caching is… ON with ‘ON’ written in green, (and ‘OFF’ in red when disabled) while the words about what it is, i.e. ‘Caching is… ’ are written in black. And some which are not so important, for example I haven’t defined REVEAL_TIES is… not set with ‘not set’ written in gray, while the words describing what it is stay in black. And if it would be set the whole phrase would be in black since there is nothing important: if this small utility for showing some undercover things is working, I will see some messages after it, if it isn’t — site will be working independently of its state. Dividing switches into important ones and not with corresponding color match should improve readability, especially for those users who are not programmers and just enabled debug mode because some guy from bugzilla said do that — for them it would help to understand what is important and what is not.

    Read the article

  • Autoscaling in a modern world&hellip;. last chapter

    - by Steve Loethen
    As we all know as coders, things like logging are never important.  Our code will work right the first time.  So, you can understand my surprise when the first time I deployed the autoscaling worker role to the actual Azure fabric, it did not scale.  I mean, it worked on my machine.  How dare the datacenter argue with that.  So, how did I track down the problem?  (turns out, it was not so much code as lack of the right certificate)  When I ran it local in the developer fabric, I was able to see a wealth of information.  Lots of periodic status info every time the autoscalar came around to check on my rules and decide to act or not.  But that information was not making it to Azure storage.  The diagnostics were not being transferred to where I could easily see and use them to track down why things were not being cooperative.  After a bit of digging, I discover the problem.  You need to add a bit of extra configuration code to get the correct information stored for you.  I added the following to my app.config: Code Snippet <system.diagnostics>     <sources>         <source name="Autoscaling General"switchName="SourceSwitch"           switchType="System.Diagnostics.SourceSwitch" >         <listeners>           <add name="AzureDiag" />             <remove name="Default"/>         </listeners>       </source>         <source name="Autoscaling Updates"switchName="SourceSwitch"           switchType="System.Diagnostics.SourceSwitch" >         <listeners>           <add name="AzureDiag" />             <remove name="Default"/>         </listeners>       </source>     </sources>     <switches>       <add name="SourceSwitch"           value="Verbose, Information, Warning, Error, Critical" />     </switches>     <sharedListeners>       <add type="Microsoft.WindowsAzure.Diagnostics.DiagnosticMonitorTraceListener,Microsoft.WindowsAzure.Diagnostics, Version=1.0.0.0, Culture=neutral,PublicKeyToken=31bf3856ad364e35" name="AzureDiag"/>     </sharedListeners>     <trace>       <listeners>         <add             type="Microsoft.WindowsAzure.Diagnostics.DiagnosticMonitorTraceListener,Microsoft.WindowsAzure.Diagnostics, Version=1.0.0.0, Culture=neutral,PublicKeyToken=31bf3856ad364e35" name="AzureDiagnostics">           <filter type="" />         </add>       </listeners>     </trace>   </system.diagnostics> Suddenly all the rich tracing info I needed was filling up my storage account.  After a few cycles of trying to attempting to scale, I identified the cert problem, uploaded a correct certificate, and away it went.  I hope this was helpful.

    Read the article

  • How Can I Start an Incognito/Private Browsing Window from a Shortcut?

    - by Jason Fitzpatrick
    Sometimes you just want to pop the browser open for a quick web search without reloading all your saved tabs; read on as we show a fellow reader how to make a quick private-browsing shortcut. Dear How-To Geek, I came up with a solution to my problem, but I need your help implementing it. I typically have a ton of tabs open in my web browser and, when I need to free up system resources when gaming or using a resource intense application, I shut down the web browser. The problem arises when I find myself needing to do quick web search while the browser is shut down. I don’t want to open it up, load all the tabs, and waste the resources in doing so all for a quick Google search. The perfect solution, it would seem, is to open up one of Chrome’s Incognito windows: it loads separate, it won’t open up all the old tabs, and it’s perfect for a quick Google search. Is there a way to launch Chrome with a single Incognito window open without having to open the browser in the normal mode (and load the bazillion tabs I have sitting there)? Sincerely, Tab Crazy That’s a rather clever work around to your problem. Since you’ve already done the hard work of figuring out the solution you need, we’re more than happy to help you across the finish line. The magic you seek is available via what are known as “command line options” which allow you to add additional parameters and switches onto a command.   By appending the command the Chrome shortcut uses, we can easily tell it to launch in Incognito mode. (And, for other readers following along at home, we can do the same thing with other browsers like Firefox). First, let’s look at Chrome’s default shortcut: If you right click on it and select the properties menu, you’ll see where the shortcut points: "C:\Program Files (x86)\Google\Chrome\Application\chrome.exe" If you run that shortcut, you’ll open up normal browsing mode in Chrome and your saved tabs will all load. What we need to do is use the command line switches available for Chrome and tell it that we want it to launch an Incognito window instead. Doing so is as simple as appending the end of the “Target” box’s command line entry with -incognito, like so: "C:\Program Files (x86)\Google\Chrome\Application\chrome.exe" -incognito We’d also recommend changing the icon to it’s easy to tell the default Chrome shortcut apart from your new Incognito shortcut. When you’re done, make sure to hit OK/Apply at the button to save the changes. You can recreate the same private-browsing-shortcut effect with other major web browsers too. Repeat shortcut editing steps we highlighted above, but change out the -incognito with -private (for Firefox and Internet Explorer) and -newprivatetab (for Opera). With just a simple command line switch applied, you can now launch a lightweight single browser window for those quick web searches without having to stop your game and load up all your saved tabs. Have a pressing tech question? Email us at [email protected] and we’ll do our best to answer it.

    Read the article