Search Results

Search found 59643 results on 2386 pages for 'data migration'.

Page 1103/2386 | < Previous Page | 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110  | Next Page >

  • Overriding as_json has no effect?

    - by Ola Tuvesson
    I'm trying to override as_json in one of my models, partly to include data from another model, partly to strip out some unnecessary fields. From what I've read this is the preferred approach in Rails 3. To keep it simple, let's say I've got something like: class Country < ActiveRecord::Base def as_json(options={}) super( :only => [:id,:name] ) end end and in my controller simply def show respond_to do |format| format.json { render :json => @country } end end Yet whatever i try, the output always contains the full data, the fields are not filtered by the ":only" clause. Basically, my override doesn't seem to kick in, though if I change it to, say... class Country < ActiveRecord::Base def as_json(options={}) {foo: "bar"} end end ...I do indeed get the expected JSON output. Have I simply got the syntax wrong?

    Read the article

  • EF and design pattern

    - by kathy
    Hello, I’m working on a high volume transactional enterprise application(asp.net, windows app, oracle app as client) which has been designed using n-tire application and SOA architecture .The application was developed in the .NET platform utilizing C#,VB.NET, Framework 3.5 (I’m planning to upgrade to the , Framework 4.0), EF( EF in the data layer level) and WCF(WCF services in the service layer level) Since this is the first project using EF, and having read about using EF in n-tier and SOA applications, and the features available in the EF Feature, I have the following points: Which design pattern should I use in EF( Simple Entities, Change Set, Self-Tracking Entities and DTOs) in the data layer level In addition Which design pattern should I use in the other tier and layer to get the best practices of EF Thanks

    Read the article

  • Generated Word 2007 prints scrunched up

    - by Brad
    Our website generates Word 2007 documents from database data by creating the xml, zipping it and sending it as a MIME attachment. Usually, this works fine. On occasion, the document will look fine on the screen, but not when printed. The letters end up scrunched together. Here is an example. This is a 1 page document, the first page is a scan of the document printed correctly, the 2nd page is a scan of the same document printed with the problem. Here is the original document. Has anyone ever seen anything similar? I cannot figure out if this is a bug in the code that generates our XML, a bug in the printer driver or a bug in Word. Any ideas would be greatly appreciated. Please note that this document does not contain any real data other than public information, but disregard the contents - this is not an official document, and only meant to illustrate our problem.

    Read the article

  • Displaying rows in multiple columns

    - by zizo
    Not sure if this is doable using sql alone or not, but here is the problem. I have a weird requirement that data needs to be displayed in columns so users can compare data quickly! Here is what the result set looks like right now CustomerID Company Active 001 ATT Y 002 ATT N 003 ATT Y 001 VZ Y 002 VZ N 003 VZ Y 001 TM Y 002 TM Y 003 TM Y Now this is how they want to see it CustomerID Company Active Company Active Company Active 001 ATT Y VZ Y TM Y 002 ATT N VZ N TM Y 003 ATT Y VZ Y TM Y Assumptions: This could be a pretty long table, that's why they want to see all companies on one row, rather than needing to scroll down to see if active or not. Nummber of companies is between 1-3 in most cases Any help is appreciated. Thanks!

    Read the article

  • Why does using ASP.NET OutputCache keep returning a 200 OK, not a 304 Not Modified?

    - by Pure.Krome
    Hi folks, i have a simple aspx page. Here's the top of it:- <%@ Page Language="C#" AutoEventWireup="true" CodeFile="Foo.aspx.cs" Inherits="Foo" %> <%@ OutputCache Duration="3600" VaryByParam="none" Location="Any" %> Now, every time I hit the page in FireFox (either hit F5 or hit enter in the url bar) I keep getting a 200 OK response. Here's a sample reply from FireBug :- Request Headers:- GET /sitemap.xml HTTP/1.1 Host: localhost.foo.com.au User-Agent: Mozilla/5.0 (Windows; U; Windows NT 6.1; en-GB; rv:1.9.2) Gecko/20100115 Firefox/3.6 Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8 Accept-Language: en-au,en-gb;q=0.7,en;q=0.3 Accept-Encoding: gzip,deflate Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.7 Keep-Alive: 115 Connection: keep-alive Cookie: <snipped> If-Modified-Since: Tue, 01 Jun 2010 07:35:17 GMT If-None-Match: "" Cache-Control: max-age=0 Response Headers:- HTTP/1.1 200 OK Cache-Control: public Content-Type: text/xml; charset=utf-8 Expires: Tue, 01 Jun 2010 08:35:17 GMT Last-Modified: Tue, 01 Jun 2010 07:35:17 GMT Etag: "" Server: Microsoft-IIS/7.5 X-Powered-By: UrlRewriter.NET 2.0.0 X-AspNet-Version: 4.0.30319 Date: Tue, 01 Jun 2010 07:35:20 GMT Content-Length: 775 Firebug Cache tab:- Last Modified Tue Jun 01 2010 17:35:20 GMT+1000 (AUS Eastern Standard Time) Last Fetched Tue Jun 01 2010 17:35:20 GMT+1000 (AUS Eastern Standard Time) Expires Tue Jun 01 2010 18:35:17 GMT+1000 (AUS Eastern Standard Time) Data Size 775 Fetch Count 105 Device disk Now, if i try it in Fiddler using the Request Builder (and no extra data) I also keep getting the same 200 OK reply. Request Headers:- GET http://localhost.foo.com.au/sitemap.xml HTTP/1.1 User-Agent: Fiddler Host: foo.com.au Response Headers:- HTTP/1.1 200 OK Cache-Control: public Content-Type: text/xml; charset=utf-8 Expires: Tue, 01 Jun 2010 07:58:00 GMT Last-Modified: Tue, 01 Jun 2010 06:58:00 GMT ETag: "" Server: Microsoft-IIS/7.5 X-Powered-By: UrlRewriter.NET 2.0.0 X-AspNet-Version: 4.0.30319 Date: Tue, 01 Jun 2010 06:59:16 GMT Content-Length: 775 It looks like it's asking to cache it but it's not :( Server is a localhost IIS7.5 on Win7. (as listed in the Response data). Can anyone see what I'm doing wrong?

    Read the article

  • Insert string between two markers

    - by user275074
    I have a requirement to insert a string between two markers. Initially I get a sting (from a file stored on the server) between #DATA# and #END# using: function getStringBetweenStrings($string,$start,$end){ $startsAt=strpos($string,$start)+strlen($start); $endsAt=strpos($string,$end, $startsAt); return substr($string,$startsAt,$endsAt-$startsAt); } I do some processing and based on the details of the string, query for some records. If there are records I need to be able to append them at the end of the string and then re-insert the string between #DATA# and #END# within the file on the server. How can I best achieve this? Is it possible to insert a record at a time in the file before #END# or is it best to manipulate the string on the server and just re-insert over the existing string in the file on the server?

    Read the article

  • C# Process flow - Datastream, XML and datagrid

    - by Farstucker
    Im looking for some advice/suggestions on how I should setup the work flow of a small application Im building. When the application is launched the datagrid will be populated via the XML file. Once running the application will receive a datastream that I hope to update the file and datagrid. So Im curious what you would suggest on how I setup the workflow (ie, split the data from the data stream and simultaneously populate the file and grid or would you suggest populating the XML file first and setting up a timer to have the grid read the file?) Im really looking for optimal performance.

    Read the article

  • C#: BackgroundWorker cloning resources?

    - by Dav
    The problem I've been struggling with this partiular problem for two days now and just run out of ideas. A little... background: we have a WinForms app that needs to access a database, construct a list of related in-memory objects from that data, and then display on a DataGridView. Important point is that we first populate an app-wide cache (List), and then create a mirror of the cache local to the form on which the DGV lives (using List constructor param). Because fetching the data takes a good few seconds (DB sits on a LAN server) to load, we decided to use a BackgroundWorker, and only refresh the DGV once the data is loaded. However, it seems that doing the loading via a BGW results in some memory leak... or an error on my part. When loaded using a blocking method call, the app consumes about 30MB of RAM; with a BGW this jumps to 80MB! While it may not seem as much anyway, our clients are not too happy about it. Relevant code Form private void MyForm_Load(object sender, EventArgs e) { MyRepository.Instance.FinishedEvent += RefreshCache; } private void RefreshCache(object sender, EventArgs e) { dgvProducts.DataSource = new List<MyDataObj>(MyRepository.Products); } Repository private static List<MyDataObj> Products { get; set; } public event EventHandler ProductsLoaded; public void GetProductsSync() { List<MyDataObj> p; using (MyL2SDb db = new MyL2SDb(MyConfig.ConnectionString)) { p = db.PRODUCTS .Select(p => new MyDataObj {Id = p.ID, Description = p.DESCR}) .ToList(); } Products = p; // tell the form to refresh UI if (ProductsLoaded != null) ProductsLoaded(this, null); } public void GetProductsAsync() { using (BackgroundWorker myWorker = new BackgroundWorker()) { myWorker.DoWork += delegate { List<MyDataObj> p; using (MyL2SDb db = new MyL2SDb(MyConfig.ConnectionString)) { p = db.PRODUCTS .Select(p => new MyDataObj {Id = p.ID, Description = p.DESCR}) .ToList(); } Products = p; }; // tell the form to refresh UI when finished myWorker.RunWorkerCompleted += GetProductsCompleted; myWorker.RunWorkerAsync(); } } private void GetProductsCompleted(object sender, RunWorkerCompletedEventArgs e) { if (ProductsLoaded != null) ProductsLoaded(this, null); } End! GetProductsSync or GetProductsAsync are called on the main thread, not shown above. Could it be that the GarbageCollector just gets lost with two threads? Or is it the task manager that shows incorrect values? Will be greateful for any responses, suggestions, criticism.

    Read the article

  • Generic Text Only printer driver mangles control codes

    - by Terry
    If an escape character (or most other characters < 0x20) is sent to the generic / text only printer it gets printed as a period. Using the code in the WinDDK is it possible to 'correct' this behaviour so that it passes it through unmodified? The general scenario for this is that some application ('user app') outputs a document to a windows printer. My application requires this data in plain text form and so what I do is run a generic / text only printer that talks to a virtual com port. This generally works fine except where the 'user app' outputs binary data to the print queue without using the correct mechanism (which seems to work fine on some printer drivers, such as the Epson POS ones, but not the generic / text only one). I've tried changing the print processor selection without success and also tried looking at the gtt files to see if I could readily map in these characters as though they were printable, but the minidriver tool won't let me do that. Any suggestions?

    Read the article

  • Jquery qtip ajax issue

    - by user272899
    Hi All, I am trying to post the value of an input box (In this case a imdb link) to my imdbgrabber.php page and have it return the info of that movie into a qtip box. Everything works fine until i try and post the variable to the imdbgrabber page. This is the code. Javascript: var link = $("#link").val(); var imdbLink = 'link='+ link; $(".moviebox").qtip({ style: { name: 'cream' }, content: { method: 'GET', data: imdbLink, url: '/includes/imdbgrabber.php', text: '<img class="throbber" src="/images/loading.gif" alt="Loading..." />' }, position: { corner: { target: 'bottomright', tooltip: 'bottomleft' } } }); HTML: <!--start moviebox--> <div class="moviebox"> <a href="#"> <img src="http://1.bp.blogspot.com/_mySxtRcQIag/S6deHcoChaI/AAAAAAAAObc/Z1Xg3aB_wkU/s200/rising_sun.jpg" /> <form method="get" action=""> <input type="text" name="link" id="link" style="display:none" value="http://www.imdb.com/title/tt0367882"/> </form> </a> </div> <!--end moviebox--> and finally the php: <?php $url=$_GET['link']; //$url = 'http://www.imdb.com/title/tt0367882/'; //get the page content $imdb_content = get_data($url); //parse for product name $name = get_match('/<title>(.*)<\/title>/isU',$imdb_content); $director = strip_tags(get_match('/<h5[^>]*>Director:<\/h5>(.*)<\/div>/isU',$imdb_content)); $plot = get_match('/<h5[^>]*>Plot:<\/h5>(.*)<\/div>/isU',$imdb_content); $release_date = get_match('/<h5[^>]*>Release Date:<\/h5>(.*)<\/div>/isU',$imdb_content); $mpaa = get_match('/<a href="\/mpaa">MPAA<\/a>:<\/h5>(.*)<\/div>/isU',$imdb_content); $run_time = get_match('/Runtime:<\/h5>(.*)<\/div>/isU',$imdb_content); $rating = get_match('/<div class="starbar-meta">(.*)<\/div>/isU',$imdb_content); ////build content //$content = '<h2>Film</h2><p>'.$name.'</p>' // . '<h2>Director</h2><p>'.$director.'</p>' // . '<h2>Plot</h2><p>'.substr($plot,0,strpos($plot,'<a')).'</p>' // . '<h2>Release Date</h2><p>'.substr($release_date,0,strpos($release_date,'<a')).'</p>' // . '<h2>MPAA</h2><p>'.$mpaa.'</p>' // . '<h2>Run Time</h2><p>'.$run_time.'</p>' // . '<h2>Full Details</h2><p><a href="'.$url.'" rel="nofollow">'.$url.'</a></p>'; //gets the match content function get_match($regex,$content) { preg_match($regex,$content,$matches); return $matches[1]; } //gets the data from a URL function get_data($url) { $ch = curl_init(); $timeout = 5; curl_setopt($ch,CURLOPT_URL,$url); curl_setopt($ch,CURLOPT_RETURNTRANSFER,1); curl_setopt($ch,CURLOPT_CONNECTTIMEOUT,$timeout); $data = curl_exec($ch); curl_close($ch); return $data; } ?> <!--start infobox--> <div class="info"> <span> <?php echo '<strong>'.$name.'</strong>' ?> </span> <img src="http://1.bp.blogspot.com/_mySxtRcQIag/S6deHcoChaI/AAAAAAAAObc/Z1Xg3aB_wkU/s200/rising_sun.jpg" /> <div class="plot"> <?php echo ''.substr($plot,0,strpos($plot,'<a')).'</div>' ?> </div> <div class="runtime"> <?php echo'<strong>Run Time</strong><br />'.$run_time.'</div>' ?> </div> <div class="releasedate"> <?php echo '<strong>Release Date</strong><br />'.substr($release_date,0,strpos($release_date,'<a')).'</div>' ?> </div> <div class="director"> <?php echo '<strong>Director</strong><br />'.$director.'' ?> </div> <div class="rating"> <?php echo '<strong>Rating</strong><br />'.$rating.'' ?> </div> </div> <!--end infobox--> I am sure it is a simple mistake somewhere but after hours of looking i thought i would ask the experts.

    Read the article

  • PHP Error - Login Script

    - by gamerzfuse
    I am creating a new login script/members directory. I am creating it from scratch without any frameworks (advice on this matter would also be appreciated). The situation: // Look up the username and password in the database $query = "SELECT admin_id, username FROM admin WHERE adminname = '$admin_user' AND password = SHA1('$admin_pass')"; $data = mysqli_query($dbc, $query); if (mysqli_num_rows($data) == 1) { This bit of code keeps giving me an error (the last line in particular): Warning: mysqli_num_rows() expects parameter 1 to be mysqli_result, boolean given in /home8/craighoo/public_html/employees/security/dir_admin.php on line 20 When echoing the query I get: SELECT admin_id, username FROM admin WHERE adminname = 'admin' AND password = SHA1('tera#byte') Thanks in advance!

    Read the article

  • good __eq__, __lt__, ..., __hash__ methods for image class?

    - by Marten Bauer
    I create the following class: class Image(object): def __init__(self, extension, data, urls=None, user_data=None): self._extension = extension self._data = data self._urls = urls self._user_data = user_data self._hex_digest = hashlib.sha1(self._data).hexDigest() Images should be equal when all values are equal. Therefore I wrote: def __eq__(self, other): if isinstance(other, Image) and self.__dict__ == other.__dict__: return True return False def __ne__(self, other): return not self.__eq__(other) def __lt__(self, other): return self.__dict__ < other.__dict__ ... But how should the __hash__ method look like? Equal Images should return equal hashes... def __hash__(self): # won't work !?! return hash(self.__dict__) Is the way I try to use __eq__, __ne__, __lt__, __hash__, ... recommend?

    Read the article

  • client side application not working as intended while using AsyncSocket

    - by Miraaj
    Hi All, I am using AsyncSocket class in a simple client-server application. As a first step I want that - as soon as connection is established between client and server, client transmit a welcome message - "connected to xyz server" to server and server displays it in textview. //The code in ClientController class is: -(void)awakeFromNib{ NSError *error = nil; if (![connectSocket connectToHost:@"192.168.0.32" onPort:25242 error:&error]) { NSLog(@"Error starting client: %@", error); return; } NSLog(@"xyz chat client started on port %hu",[connectSocket localPort]); } - (void)onSocket:(AsyncSocket *)sock didConnectToHost:(NSString *)host port:(UInt16)port{ [sock writeData:[@"connected to xyz server" dataUsingEncoding:NSUTF8StringEncoding] withTimeout:30.0 tag:0]; } - (void)onSocket:(AsyncSocket *)sock didReadData:(NSData *)data withTag:(long)tag{ // some relevant code goes here } - (void)onSocket:(AsyncSocket *)sock didWriteDataWithTag:(long)tag{ NSLog(@"within didWriteDataWithTag:"); // getting this message, means it should have written something to remote socket but // delegate- onSocket:didReadData:withTag: at server side is not getting invoked } // The code in ServerController class is: - (IBAction)startStop:(id)sender{ NSLog(@"startStopAction"); if(!isRunning) { NSError *error = nil; if(![listenSocket acceptOnPort:INPUT_PORT error:&error]) { NSLog(@"Error starting server: %@", error); return; } NSLog(@"Echo server started on port %hu",[listenSocket localPort]); isRunning = YES; [sender setTitle:@"Stop"]; } else { // Stop accepting connections [listenSocket disconnect]; // Stop any client connections int i; for(i = 0; i < [connectedSockets count]; i++) { // Call disconnect on the socket, // which will invoke the onSocketDidDisconnect: method, // which will remove the socket from the list. [[connectedSockets objectAtIndex:i] disconnect]; } NSLog(@"Stopped Echo server"); isRunning = false; [sender setTitle:@"Start"]; } } - (void)onSocket:(AsyncSocket *)sock didAcceptNewSocket:(AsyncSocket *)newSocket{ [connectedSockets addObject:newSocket]; } - (void)onSocket:(AsyncSocket *)sock didConnectToHost:(NSString *)host port:(UInt16)port{ NSLog(@"Accepted client %@:%hu", host, port); // it is getting displayed [sock readDataToData:[AsyncSocket CRLFData] withTimeout:READ_TIMEOUT tag:0]; } - (void)onSocket:(AsyncSocket *)sock didReadData:(NSData *)data withTag:(long)tag{ NSString *msgReceived = [[[NSString alloc] initWithData:data encoding:NSUTF8StringEncoding] autorelease]; NSLog(@"msgReceived in didReadData- %@",msgReceived); // it is not getting displayed [outputView insertText:msgReceived]; [sock readDataToData:[AsyncSocket CRLFData] withTimeout:READ_TIMEOUT tag:0]; } Can anyone suggest me where I may be wrong?? Thanks in advance...... Miraaj

    Read the article

  • Multi choice form field in Django

    - by Dingo
    Hi! I'am developing application on app-engine-path. I would like to make form with multichoice (acceptably languages for user). Code look like this: Language settings: settings.LANGUAGES = ((u"cs", u"Ceština"), (u"en", u"English")) Form model: class UserForm(forms.ModelForm): first_name = forms.CharField(max_length=100) last_name = forms.CharField(max_length=100) languages = forms.MultipleChoiceField(widget=forms.CheckboxSelectMultiple, choices=settings.LANGUAGES) The form is rendered o.k. (all languages have checkbox. IDs, NAMEs is ok.) But if I save some languages for user, those languages don't check checkboxes. User model look like this class User(User): #... languages = db.StringListProperty() #... and view: def edit_profile(request): user = request.user if request.method == 'POST': form = UserForm(request.POST) if form.is_valid(): # ... else: form = UserForm(instance=user) data = {"user":user, "form": form} return render_to_response(request, 'user_profile/user_profile.html', data)

    Read the article

  • how to get the sql connection

    - by sweetsecret
    FS_Setting is a VB class which has all the details of the connections ie: Public Class FS_Setting Public Function Get_RS_Connection() As SqlConnection Try Get_RS_Connection = New SqlConnection("Data Source=***********;User ID=sa;Password=*****;database=*********") Catch ex As System.Exception Throw New System.Exception("Get_RS_Connection Error:" + ex.Message) End Try End Function I need to call the function Get_RS_Connection() in a different class instead of getting the connection all the way again and hard coding.... I want to call the above class where the SQL connection is declared Namespace FS_Library Public Class FS_Errorlog Inherits FS_BaseClass Try **cn = New SqlConnection("Data Source=***********;UserID=sa;Password=*****;database=*********")** cmd = New SqlCommand("dbo.FS_ErrorLog_ADD", cn) cmd.CommandType = CommandType.StoredProcedure cmd.CommandTimeout = Convert.ToInt32(ConfigurationSettings.AppSettings("Command_Timeout")) Me.AddParameter(cmd, "@p_tableKey", SqlDbType.Int, tableKey) Me.AddParameter(cmd, "@p_FunctionCode", SqlDbType.Int, FunctionCode) Me.AddParameter(cmd, "@p_TableAlias", SqlDbType.VarChar, TableAlias) Me.AddParameter(cmd, "@p_ValidationCode", SqlDbType.Int, ValidationCode) If Filename = "" Then Filename = "N/A" End If Me.AddParameter(cmd, "@p_FileName", SqlDbType.VarChar, Filename) Me.AddParameter(cmd, "@p_Message", SqlDbType.VarChar, Message) Me.AddParameter(cmd, "@p_CreateUser", SqlDbType.VarChar, userID) Me.AddParameter(cmd, "@p_UserActionID", SqlDbType.UniqueIdentifier, UserActionID) cn.Open()

    Read the article

  • Could an ontology suitably replace an RDBMS for a web app?

    - by Thomas
    I'm considering storing the content of a web app in an RDF or OWL ontology instead of an RDBMS. However, when I research ontologies they seem to always exist in the context of publicly accessible data stores serving as the backbone of the semantic web. I've never heard of them being used as the content engine behind a web app. Is it reasonable to use an ontology instead of an RDBMS for such an application? (Again, this is just for content. User data, commerce and stuff like that will stay in a database as I see no need to reinvent the wheel there.)

    Read the article

  • Does a multithreaded crawler in Python really speed things up?

    - by beagleguy
    Was looking to write a little web crawler in python. I was starting to investigate writing it as a multithreaded script, one pool of threads downloading and one pool processing results. Due to the GIL would it actually do simultaneous downloading? How does the GIL affect a web crawler? Would each thread pick some data off the socket, then move on to the next thread, let it pick some data off the socket, etc..? Basically I'm asking is doing a multi-threaded crawler in python really going to buy me much performance vs single threaded? thanks!

    Read the article

  • The method split(String) is undefined for the type String

    - by pi
    I am using Pulse - the Plugin Manager for Eclipse and installed. I have the Eclipse 3.5 for mobile development(Pulsar) profile with a couple other profiles. I realized that the split() method called on a string from code such as below: String data = "one, two, three, four"; data.split(","); generates the error: "The method split(String) is undefined for the type String". I am aware that the split() method did not exist before Java's JRE 1.4 and perhaps could be the cause of the problem. The problem is I don't think I have jre/sdk versions installed. Perhaps there's one in-built with the Pulsar profile and needs editing - but I couldn't tell what settings (and where) needs tweaking. I have checked WindowsPreferencesJavaInstalled JREs and it's set to = jre1.4. Please help thanks.

    Read the article

  • R: ggplot2, how to add a number of layers to a plot at once to reduce code

    - by John
    library(ggplot2) This code produces a nice looking plot: qplot(cty, hwy, data = mpg, colour = displ) + scale_y_log2() + labs(x="x axis") + labs(y="y axis") + opts(title = "my title") But I want to setup variables to try and to reduce code repetition: log_scale <- scale_y_log2() xscale <- labs(x="x axis") yscale <- labs(y="y axis") title <- opts(title = "my title") my_scales <- c(log_scale, xscale, yscale, title) # make a variable to hold the scale info changes above So that I can do this and add a bunch of things at the same time: qplot(cty, hwy, data = mpg, colour = displ) + my_scales # add these to your plot. but I get this error: Error in object$class : $ operator is invalid for atomic vectors I realize that the things going into my_scales need to be layers / different types of objects, but I don't see what they should be.

    Read the article

  • Using C# and VB.NET in one solution

    - by Younes
    I'm busy on a small project to convert an Access2003 db to .NET. I am trying to integrate my functionality in an excisting project that is being used for Administration of some kind. The code in this project is vb.net. I started by setting up my Data Access Layer, which seems to work fine. I can make new web pages that acces the data I need. However when i start to use class files to set up my Business Logic Layer i can't build my project when using C# instead of VB. I Dislike VB and like to program in C# as i know the syntax alot better etc. Is it possible to program using C# knowing that VB.NET was the language chosen to buold the entire project on? If not, what will be the smartest way to integrate my module into the project using my favorite programming language? (Make a project and reference to the dll?)

    Read the article

  • Connect ps/2->usb keyboard to linux?

    - by Daniel
    I have a lovely ancient ergonomic keyboard (no name SK - 6000) connected via a DIN-ps/2 adapter to a ps/2-usb adapter to my docking station. After Grub it stops working. It takes either suspending and waking up or replugging it while Linux is running to get it to work. No extra kernel modules get loaded for this. When it works and I restart without power off, it will work immediately. Even when it does not work, it is visible (lsusb device number varies but output is identical whether working or not): $ lsusb -v -s 001:006 Bus 001 Device 006: ID 0a81:0205 Chesen Electronics Corp. PS/2 Keyboard+Mouse Adapter Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 8 idVendor 0x0a81 Chesen Electronics Corp. idProduct 0x0205 PS/2 Keyboard+Mouse Adapter bcdDevice 0.10 iManufacturer 1 CHESEN iProduct 2 PS2 to USB Converter iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 59 bNumInterfaces 2 bConfigurationValue 1 iConfiguration 2 PS2 to USB Converter bmAttributes 0xa0 (Bus Powered) Remote Wakeup MaxPower 100mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 1 Boot Interface Subclass bInterfaceProtocol 1 Keyboard iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.10 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 64 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 10 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 1 Boot Interface Subclass bInterfaceProtocol 2 Mouse iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.10 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 148 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 10 Device Status: 0x0000 (Bus Powered) $ ll -R /sys/bus/hid/drivers/ /sys/bus/hid/drivers/: total 0 drwxr-xr-x 2 root root 0 Jul 8 2012 generic-usb/ /sys/bus/hid/drivers/generic-usb: total 0 lrwxrwxrwx 1 root root 0 Jul 7 23:33 0003:046D:C03D.0003 -> ../../../../devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.2/1-1.2.2:1.0/0003:046D:C03D.0003/ lrwxrwxrwx 1 root root 0 Jul 7 23:33 0003:0A81:0205.0001 -> ../../../../devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001/ lrwxrwxrwx 1 root root 0 Jul 7 23:33 0003:0A81:0205.0002 -> ../../../../devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.1/0003:0A81:0205.0002/ --w------- 1 root root 4096 Jul 7 23:32 bind lrwxrwxrwx 1 root root 0 Jul 7 23:33 module -> ../../../../module/usbhid/ --w------- 1 root root 4096 Jul 7 23:32 new_id --w------- 1 root root 4096 Jul 8 2012 uevent --w------- 1 root root 4096 Jul 7 23:32 unbind When replugging, dmesg shows this (which except for the 1st line and different input numbers already came at boot time): [ 1583.295385] usb 1-1.2.1: new low-speed USB device number 6 using ehci_hcd [ 1583.446514] input: CHESEN PS2 to USB Converter as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/input/input17 [ 1583.446817] generic-usb 0003:0A81:0205.0001: input,hidraw0: USB HID v1.10 Keyboard [CHESEN PS2 to USB Converter] on usb-0000:00:1a.0-1.2.1/input0 [ 1583.454764] input: CHESEN PS2 to USB Converter as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.1/input/input18 [ 1583.455534] generic-usb 0003:0A81:0205.0002: input,hidraw1: USB HID v1.10 Mouse [CHESEN PS2 to USB Converter] on usb-0000:00:1a.0-1.2.1/input1 [ 1583.455578] usbcore: registered new interface driver usbhid [ 1583.455584] usbhid: USB HID core driver So I tried $ sudo udevadm test /sys/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001/hidraw/hidraw0 run_command: calling: test adm_test: version 175 This program is for debugging only, it does not run any program, specified by a RUN key. It may show incorrect results, because some values may be different, or not available at a simulation run. parse_file: reading '/lib/udev/rules.d/40-crda.rules' as rules file parse_file: reading '/lib/udev/rules.d/40-fuse.rules' as rules file ... parse_file: reading '/lib/udev/rules.d/40-usb-media-players.rules' as rules file parse_file: reading '/lib/udev/rules.d/40-usb_modeswitch.rules' as rules file ... parse_file: reading '/lib/udev/rules.d/42-qemu-usb.rules' as rules file ... parse_file: reading '/lib/udev/rules.d/69-cd-sensors.rules' as rules file add_rule: IMPORT found builtin 'usb_id', replacing /lib/udev/rules.d/69-cd-sensors.rules:76 ... parse_file: reading '/lib/udev/rules.d/77-mm-usb-device-blacklist.rules' as rules file ... parse_file: reading '/lib/udev/rules.d/85-usbmuxd.rules' as rules file ... parse_file: reading '/lib/udev/rules.d/95-upower-hid.rules' as rules file parse_file: reading '/lib/udev/rules.d/95-upower-wup.rules' as rules file parse_file: reading '/lib/udev/rules.d/97-bluetooth-hid2hci.rules' as rules file udev_rules_new: rules use 271500 bytes tokens (22625 * 12 bytes), 44331 bytes buffer udev_rules_new: temporary index used 76320 bytes (3816 * 20 bytes) udev_device_new_from_syspath: device 0x7f78a5e4d2d0 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001/hidraw/hidraw0' udev_device_new_from_syspath: device 0x7f78a5e5f820 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001/hidraw/hidraw0' udev_device_read_db: device 0x7f78a5e5f820 filled with db file data udev_device_new_from_syspath: device 0x7f78a5e60270 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001' udev_device_new_from_syspath: device 0x7f78a5e609c0 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0' udev_device_new_from_syspath: device 0x7f78a5e61160 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1' udev_device_new_from_syspath: device 0x7f78a5e61960 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2' udev_device_new_from_syspath: device 0x7f78a5e62150 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1/1-1' udev_device_new_from_syspath: device 0x7f78a5e62940 has devpath '/devices/pci0000:00/0000:00:1a.0/usb1' udev_device_new_from_syspath: device 0x7f78a5e630f0 has devpath '/devices/pci0000:00/0000:00:1a.0' udev_device_new_from_syspath: device 0x7f78a5e638a0 has devpath '/devices/pci0000:00' udev_event_execute_rules: no node name set, will use kernel supplied name 'hidraw0' udev_node_add: creating device node '/dev/hidraw0', devnum=251:0, mode=0600, uid=0, gid=0 udev_node_mknod: preserve file '/dev/hidraw0', because it has correct dev_t udev_node_mknod: preserve permissions /dev/hidraw0, 020600, uid=0, gid=0 node_symlink: preserve already existing symlink '/dev/char/251:0' to '../hidraw0' udev_device_update_db: created empty file '/run/udev/data/c251:0' for '/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001/hidraw/hidraw0' ACTION=add DEVNAME=/dev/hidraw0 DEVPATH=/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001/hidraw/hidraw0 MAJOR=251 MINOR=0 SUBSYSTEM=hidraw UDEV_LOG=6 USEC_INITIALIZED=969079051 The later lines sound like it's already there. And none of these awakes the keyboard: $ sudo udevadm trigger --verbose --sysname-match=usb* /sys/devices/pci0000:00/0000:00:1a.0/usb1 /sys/devices/pci0000:00/0000:00:1a.0/usbmon/usbmon1 /sys/devices/pci0000:00/0000:00:1d.0/usb2 /sys/devices/pci0000:00/0000:00:1d.0/usbmon/usbmon2 /sys/devices/virtual/usbmon/usbmon0 $ sudo udevadm trigger --verbose --sysname-match=hidraw0 /sys/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2/1-1.2.1/1-1.2.1:1.0/0003:0A81:0205.0001/hidraw/hidraw0 $ sudo udevadm trigger I also tried this to no avail: # echo -n 0003:0A81:0205.0001 > /sys/bus/hid/drivers/generic-usb/bind ksh: echo: write to 1 failed [No such device] # echo -n 0003:0A81:0205.0001 > /sys/bus/hid/drivers/generic-usb/unbind # echo -n 0003:0A81:0205.0001 > /sys/bus/hid/drivers/generic-usb/bind # echo usb1 >/sys/bus/usb/drivers/usb/unbind # echo usb1 >/sys/bus/usb/drivers/usb/bind What else should I try to get the same result as replugging or suspending, by just issuing a command?

    Read the article

  • How to validate HTTP request headers before receiving request body using WCF

    - by anelson
    I'm implementing a REST service using WCF which will be used to upload very large files. The HTTP headers in this request will communicate information which will be validated prior to allowing the upload to proceed (things like permissions, available disk space, etc). It's possible this validation will fail resulting in an error response. I'd like to do this validation prior to the client sending the body of the request, so it has a chance to detect failure before uploading potentially gigabytes of data. RESTful web services use the HTTP 1.1 Expect: 100-continue in the request to implement this. For example Amazon S3's REST API can validate your key and ACLs in response to an object PUT operation, returning 100 Continue if all is well, indicating you may proceed to send your data. I've rummaged around the WCF documentation and I just can't see a way to accomplish this without doing some pretty low-level hooking into the HTTP request processing pipeline. How would you suggest I solve this problem?

    Read the article

  • WPF USer Control viewmodel binding

    - by Senthilkumar
    HI Can any one suggest me how bind viewmodel to a usercontrol.. Also please share different way of doing that.. I have added viewmodel and view into my xaml file in namespace and in the user control resource tag.. i have defined a data template with data type as the viewmodel wh i have wrote.. inside that i have added my view (i mean the same usercontrol ih which im editing now is it possible -- please let me know).. I have used content control with content={Binding}.. and contenttemplate as a datatemplate.. in that i have reffered the property which i want to bind from viewmodel).. but its not binding as such.. My query is different ways of binding viewmodel to view in UserControlLibrary Project ?

    Read the article

  • Creating CCD document from scratch (JAVA)

    - by Nikhil Patil
    Hi, I'm trying to build a CCD document. My application has some raw data which has to be converted into a CCD document. And I've no idea where I should start from!! From this thread I learned that MDHT and Braid can be used to create a CCD document. But thats all I could grasp. I thought that I need a CCD XSD, a java library which will transform my raw data into a CCD document using this XSD ( or may be the library itself takes care of it ). But I'm stuck at both. I suppose the CCD XSD has to be purchased. If I get hold of the XSD, how should I proceed ahead? I got really confused reading the Braid and MDHT sites. Sorry, I'm a complete nOOb in this domain. Can anyone guide me?

    Read the article

  • How to add correct cancellation when downloading a file with the example in the samples of the new P

    - by Mike
    Hello everybody, I have downloaded the last samples of the Parallel Programming team, and I don't succeed in adding correctly the possibility to cancel the download of a file. Here is the code I ended to have: var wreq = (HttpWebRequest)WebRequest.Create(uri); // Fire start event DownloadStarted(this, new DownloadStartedEventArgs(remoteFilePath)); long totalBytes = 0; wreq.DownloadDataInFileAsync(tmpLocalFile, cancellationTokenSource.Token, allowResume, totalBytesAction => { totalBytes = totalBytesAction; }, readBytes => { Log.Debug("Progression : {0} / {1} => {2}%", readBytes, totalBytes, 100 * (double)readBytes / totalBytes); DownloadProgress(this, new DownloadProgressEventArgs(remoteFilePath, readBytes, totalBytes, (int)(100 * readBytes / totalBytes))); }) .ContinueWith( (antecedent ) => { if (antecedent.IsFaulted) Log.Debug(antecedent.Exception.Message); //Fire end event SetEndDownload(antecedent.IsCanceled, antecedent.Exception, tmpLocalFile, 0); }, cancellationTokenSource.Token); I want to fire an end event after the download is finished, hence the ContinueWith. I slightly changed the code of the samples to add the CancellationToken and the 2 delegates to get the size of the file to download, and the progression of the download: return webRequest.GetResponseAsync() .ContinueWith(response => { if (totalBytesAction != null) totalBytesAction(response.Result.ContentLength); response.Result.GetResponseStream().WriteAllBytesAsync(filePath, ct, resumeDownload, progressAction).Wait(ct); }, ct); I had to add the call to the Wait function, because if I don't, the method exits and the end event is fired too early. Here are the modified method extensions (lot of code, apologies :p) public static Task WriteAllBytesAsync(this Stream stream, string filePath, CancellationToken ct, bool resumeDownload = false, Action<long> progressAction = null) { if (stream == null) throw new ArgumentNullException("stream"); // Copy from the source stream to the memory stream and return the copied data return stream.CopyStreamToFileAsync(filePath, ct, resumeDownload, progressAction); } public static Task CopyStreamToFileAsync(this Stream source, string destinationPath, CancellationToken ct, bool resumeDownload = false, Action<long> progressAction = null) { if (source == null) throw new ArgumentNullException("source"); if (destinationPath == null) throw new ArgumentNullException("destinationPath"); // Open the output file for writing var destinationStream = FileAsync.OpenWrite(destinationPath); // Copy the source to the destination stream, then close the output file. return CopyStreamToStreamAsync(source, destinationStream, ct, progressAction).ContinueWith(t => { var e = t.Exception; destinationStream.Close(); if (e != null) throw e; }, ct, TaskContinuationOptions.ExecuteSynchronously, TaskScheduler.Current); } public static Task CopyStreamToStreamAsync(this Stream source, Stream destination, CancellationToken ct, Action<long> progressAction = null) { if (source == null) throw new ArgumentNullException("source"); if (destination == null) throw new ArgumentNullException("destination"); return Task.Factory.Iterate(CopyStreamIterator(source, destination, ct, progressAction)); } private static IEnumerable<Task> CopyStreamIterator(Stream input, Stream output, CancellationToken ct, Action<long> progressAction = null) { // Create two buffers. One will be used for the current read operation and one for the current // write operation. We'll continually swap back and forth between them. byte[][] buffers = new byte[2][] { new byte[BUFFER_SIZE], new byte[BUFFER_SIZE] }; int filledBufferNum = 0; Task writeTask = null; int readBytes = 0; // Until there's no more data to be read or cancellation while (true) { ct.ThrowIfCancellationRequested(); // Read from the input asynchronously var readTask = input.ReadAsync(buffers[filledBufferNum], 0, buffers[filledBufferNum].Length); // If we have no pending write operations, just yield until the read operation has // completed. If we have both a pending read and a pending write, yield until both the read // and the write have completed. yield return writeTask == null ? readTask : Task.Factory.ContinueWhenAll(new[] { readTask, writeTask }, tasks => tasks.PropagateExceptions()); // If no data was read, nothing more to do. if (readTask.Result <= 0) break; readBytes += readTask.Result; if (progressAction != null) progressAction(readBytes); // Otherwise, write the written data out to the file writeTask = output.WriteAsync(buffers[filledBufferNum], 0, readTask.Result); // Swap buffers filledBufferNum ^= 1; } } So basically, at the end of the chain of called methods, I let the CancellationToken throw an OperationCanceledException if a Cancel has been requested. What I hoped was to get IsFaulted == true in the appealing code and to fire the end event with the canceled flags and the correct exception. But what I get is an unhandled exception on the line response.Result.GetResponseStream().WriteAllBytesAsync(filePath, ct, resumeDownload, progressAction).Wait(ct); telling me that I don't catch an AggregateException. I've tried various things, but I don't succeed to make the whole thing work properly. Does anyone of you have played enough with that library and may help me? Thanks in advance Mike

    Read the article

< Previous Page | 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110  | Next Page >