  • NetApp and SQL Server?

    - by Edinor
    Do you have any good or bad experiences to share running SQL Server OLTP Systems on NetApp appliances? I have been working with a small, relatively low-volume cluster with a lower-end NetApp device, and I have found the environment to be generally unstable, at least compared to my experiences with other SANs, iSCSI arrays, and DAS setups. I struggle to believe that RAID DP and WAFL are more than fairy-dust technologies. A solution has been proposed to me that I just need a bigger, better NetApp, with PAM cards and other cool technology I've not heard of, and I feel like I would be better off spending a quarter of that on good direct-attached drives and a beefy server. At the same time, I feel that an Enterprise-class SAN should be something I can count on to be consistently a more stable, better performer than the less expensive solution I might propose. Are you a SQL Server DBA in an OLTP environment and love your NetApp? If you don't like them, why not?

    Read the article

  • LVM2 vs MDADM performance

    - by archer
    I've used MDADM + LVM2 on many boxes for quite a while. MDADM was serving for both RAID0 and RAID1 arrays, while LVM2 where used for logical volumes on top of MDADM. Recently I've found that LVM2 could be used w/o MDADM (thus minus one layer, as the result - less overhead) for both mirroring and stripping. However, some guys claims that READ PERFORMANCE on LVM2 for mirrored array is not that fast as for LVM2 (linear) on top of MDADM (RAID1) as LVM2 does not read from 2+ devices at a time, but use 2nd and higher devices in case of 1st device failure. MDADM reads from 2 devices at a time (even in mirrored mode). Who could confirm that?

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS storage solutions. In addition, what effect does battery-backed write cache (BBWC) have in ZFS storage?

    Read the article

  • RAID FS detection at boot time

    - by alex
    An excerpt from dmesg: md: Autodetecting RAID arrays. md: Scanned 2 and added 2 devices. md: autorun ... md: considering sdb1 ... md: adding sdb1 ... md: adding sda1 ... md: created md1 md: bind<sda1> md: bind<sdb1> md: running: <sdb1><sda1> raid1: raid set md1 active with 2 out of 2 mirrors md1: detected capacity change from 0 to 1500299198464 md: ... autorun DONE. md1: unknown partition table EXT3-fs (md1): error: couldn't mount because of unsupported optional features (240) EXT2-fs (md1): error: couldn't mount because of unsupported optional features (240) EXT4-fs (md1): mounted filesystem with ordered data mode Is it OK that kernel tries to mount an ext4 raid as ext3, ext2 first? Is there a way to tell it to skip those two steps? Just in case: /dev/md1 / ext4 noatime 0 1 TIA.

    Read the article

  • MS Server 2003 Activiation Loop

    - by RPGonzo
    Recently we had a motherboard failure on a terminal server so we replaced the faulty motherboard, re-setup the RAID arrays (same motherboard but still wouldn't recognize old RAID setup) and continued to recover the system from a previous backup. No problem up to here, after restoring the system you are prompted to reboot and than login. On login we get a message box stating that Windows needs to be activated do you want to activate now, press yes but than the OS proceeds to log you off and do nothing at all. You can try over and over but to no avail. Found a few articles about a glitch in the activation script and how to reset it, tried that with the same results. Hoping someone can share some knowledge if you have seen this before? Thanks!

    Read the article

  • Advantages of multiple SQL Server files with a single RAID array

    - by Dr Giles M
    Originally posted on stack overflow, but re-worded. Imagine the scenario : For a database I have RAID arrays R: (MDF) T: (transaction log) and of course shared transparent usage of X: (tempDB). I've been reading around and get the impression that if you are using RAID then adding multiple SQL Server NDF files sitting on R: within a filegroup won't yeild any more improvements. Of course, adding another raid array S: and putting an NDF file on that would. However, being a reasonably savvy software person, it's not unthinkable to hypothesise that, even for smaller MDFs sitting on one RAID array that SQL Server will perform growth and locking operations (for writes) on the MDF, so adding NDFs to the filegroup even if they sat on R: would distribute the locking operations and growth operations allowing more throughput? Or does the time taken to reconstruct the data from distributed filegroups outweigh the benefits of reduced locking? I'm also aware that the behaviour and benefits may be different for tables/indeces/log. Is there a good site that distinguishes the benefits of multiple files when RAID is already in place?

    Read the article

  • Database Server Hardware components (order of importance), CPU speed VS CPU cache vs RAM vs DISK

    - by nulltorpedo
    I am new to database world and would like to know what are crucial hardware specs when it comes to database performance. I have searched the internet and found this so far (In order of decreasing importance): 1) Hard Disk: Get an SSD basically (much more IOPS than spinners) 2) Memory: Get as much as you can afford 3) CPU: For the same $ spent, prefer larger cache size over speed. Are these findings sensible? EDIT: I would like to focus on CPU speed VS CPU cache size. EDIT2: The database is used to store some combination of ints and int arrays with few text fields. There are a lot of Select queries looking for existing entries. If entry is not found, then insert it. I would say most of processing would be trying to find a match across a table with 200 columns and 20k rows. The insert statements are very few. EDIT3: Also, we have a lot of views (basically select queries).

    Read the article

  • Will adding a SSD cache device to my ZFS storage improve performance?

    - by Sysadminicus
    The server has 4GB of RAM and my zpool is made up of 15.5k SAS drives arranged like this: NAME STATE READ WRITE CKSUM tank ONLINE 0 0 0 raidz1-0 ONLINE 0 0 0 c0t2d0 ONLINE 0 0 0 c0t3d0 ONLINE 0 0 0 c0t4d0 ONLINE 0 0 0 c0t5d0 ONLINE 0 0 0 c0t6d0 ONLINE 0 0 0 c0t7d0 ONLINE 0 0 0 c0t8d0 ONLINE 0 0 0 raidz1-1 ONLINE 0 0 0 c0t10d0 ONLINE 0 0 0 c0t11d0 ONLINE 0 0 0 c0t12d0 ONLINE 0 0 0 c0t13d0 ONLINE 0 0 0 c0t14d0 ONLINE 0 0 0 spares c0t9d0 AVAIL c0t1d0 AVAIL The primary use is as an NFS store for a couple VMWare ESXi servers. I can't do any "true" benchmarks because this is a production system (no budget for test systems), but using dd and bonnie++ I can't get more than ~40-50MB/s writes and ~70-90MB/s reads. It seems I should be able to do much better, but I'm not sure where to optimize. Based on what I've read, I think dropping in a OCZ Vertex 2 Pro SSD as my L2ARC is going to be the best bang-for-the-buck to improve througput. Is there something else I should be looking into to help performance? If not... How do I know how big a cache device I need? Am I safe with only a single SSD as my cache device?

    Read the article

  • ML 350 additional SATA RAID controller (mirror only)

    - by Nicholas
    I have a Proliant ML350 G8 with two SAS raid arrays currently set up - thereby maxing the default P420i raid controller. I need to set up a large video dump space in addition to this existing set-up (for non backed up, non-critical, temporary storage). I had planned to just add a 2TB SATA disk and plug it into the motherboard. However I it occurred to me the motherboard might have built-in mirror RAID support? Therefore I could use two SATA disks and have some semblance of redundancy. Is this possible? Or would I need to get a cheap raid card? Any recommendations?

    Read the article

  • Verify server performance

    - by George Kesler
    I'm looking for a quick and SIMPLE way to verify that new servers are performing as expected. The most important metric is disk performance, second is network performance. I’m trying to prevent problems caused by misconfiguration of RAID arrays, NIC teaming etc. The solution should work with both physical and virtual servers. I don’t need sophisticated analysis with different workloads, just one set of benchmarks which I would run against a reference server and later compare to new ones. One problem is that most benchmarks are not giving accurate results when running on a VM.

    Read the article

  • Reduce power consumption of gaming computer while idle

    - by White Phoenix
    This is my current build: EVGA X58 (first generation) motherboard Intel i7 965 clocked @ 3.3 Ghz 3x DDR3-1600 Corsair RAM at stock timings and voltages Corsair AX750 80 Plus Gold PSU 1 Optical Drive 1 Seagate 7200.10 500 GB drive 2x Western Digital Caviar Black 1 TB drives OCZ Vertex 1 60 GB EVGA GTX 460 oc'd at 800/1600/1850 Antec 1200 case HT-Omega Striker 7.1 Sound Card Windows 7 32-bit Professional (PAE Enabled) I've already seen this post Reduce power use on computer and this post How do I lower power consumption of my computer and while useful, I'm looking for answers specific to my build and OS. I'm pretty sure this build is a energy-intensive build by default, but I want to try to reduce the amount of energy my build uses when I leave it idle (when I go to bed or go out, etc). The first requirement for this machine is that I need to leave it on, so I cannot turn it off while it's being unused. I run it as a file server for personal reasons and I also leave it on in case people leave me messages on various IM services and chat clients (IRC, MSN, Steam, XFire, Pidgin, etc). I'm also unable to replace the parts in my computer with a cheaper "greener" part. What are some ways to minimize the amount of power the machine uses? I'm already using a high efficiency power supply (80 Plus Gold), but I imagine there's other things that can be done in the BIOS and Windows' power settings to reduce power usage while I'm not using the computer. From what I can tell, I can't use Sleep since that'll disable network access (whole reason why I leave the computer on in the first place). I already turn off my monitor when it's not in use. I enabled Intel SpeedStep within the BIOS (I know, I have a 965 and why am I enabling SpeedStep?) Should I bring the graphics card back to stock speeds and lower the clock on the processor even more? Main reason why I'm asking is I think this computer alone is the reason why my power bill is high, so I want to reduce its consumption to as low as possible without having to shut the thing down.

    Read the article

  • Installing Windows on HP Proliant Servers without SmartStart

    - by Fitzroy
    I have a PXE server for deploying Windows XP and Windows 7 to workstations. The process is as follows: Boot the workstation from the NIC. Workstation sends a DHCP request. DHCP server responds with an IP address and the location of the PXE server. Workstation downloads WinPE image file from PXE server via TFTP Workstation stores WinPE image file in memory and executes it. Once booted into WinPE, I connect to a network share to gain access to either the Windows XP or Windows 7 installation files. A custom script is launched to guide you through the process of formatting and partitioning the hard drive(s) (using DISKPART and FORMAT). Another custom script asks for details such as the hostname to assign to the workstation. The answers provided are used to build an unattended answer file (SIF [Setup Information File] for WinXP and XML for Win7). The Windows setup EXE is launched, passing the unattended answer file to it as a parameter. The Windows XP and Windows 7 installation sources have been customised to include the drivers for our Dell workstations. They also run a number of scripts upon first booting up to install software packages. This process works very well for our workstations and I would now like to use it for building our servers too. The vast majority of our servers are HP Proliant DL360 G6, DL380 G5 and DL380 G6. They’re running Windows Server 2003 (various editions) or 2008 (various editions). To date, we have always built the HP Proliant servers using the SmartStart CD provided. SmartStart does three useful things for us: Setup RAID with HP Array Configuration Utility (ACU). Installs and configures SNMP Installs various HP Tools for Windows (HP Array Configuration Utility, HP Array Diagnostic Utility, HP Proliant Integrated Management Log Viewer, etc) Using SmartStart I have never had to manually download and install Windows drivers for network, sound, video, etc. I'm not sure if this is because SmartStart copies drivers from the CD during setup, or whether Windows just has the drivers natively in its driver CAB. If I abandon the SmartStart CD in favour of my PXE server I would have to do the following: As I wont have access to ACU, I'll configure the RAID (before booting to the PXE server) by pressing F8 (during the boot process) to access Option ROM Configuration for Arrays (ORCA). Installation of SNMP and the HP Tools will have to be installed once the Windows installation is complete using the Proliant Support Pack. Is this method OK? Is there anything that the SmartStart CD does that I'll be unable to do by other means? Are there any disadvantages to not using the SmartStart CD? Many thanks. UPDATE 05/01/12 I’ve been reading through the SmartStart Scripting Toolkit documentation. The scripting toolkit contains command line tools which work within WinPE and can such things as configure BIOS settings, configure an array and setup ILO. I’m personally not too bothered about configuring BIOS settings as I rarely deviate from the defaults (unless the server is to be a Hyper-V host). I’m not too fussed about being able to configure the array from within WinPE, as I’m happy to just press F8 and use Option ROM Configuration for Arrays (ORCA). Although, if it’s easy enough to do, I will explore this further, as it saves time if everything can be configured from within WinPE. One of the nice features all the tools possess is that you can pass input files to them. EG. Configure one server to your requirements, capture its configuration to a file (using the appropriate tool), you can then use the tool on other servers passing the input file with the captured configuration. Array controller drivers appear to be included with the toolkit along with example of how to incorporate them within a WinPE build. I suppose WinPE won’t be able to see logical volumes (I.E 2x physical disks in a RAID 1 configuration) without the array controller drivers? I mentioned in my post that SmartStart normally installs a bunch of Windows HP tools for you. I’ve had a look today, and if you run the SmartStart CD from within Windows all the tools can be installed. Therefore I can do this after the Windows installation is complete. The SmartStart CD appears to contain a lot Windows drivers. I can customise my Windows 2008 source to incorporate these drivers. However, I understand that incorporating an array controller driver is a little different to most drivers. I believe that you have to provide the driver during the very early stages of the Windows setup. I’m working through the Scripting Toolkit documentation to try and work this out...

    Read the article

  • Best SQL Server Configuration with this hardware.

    - by DavidStein
    I just received my new SQL Server from Dell. The server will be serve approximately 15 OLTP databases which average 10GB in size. Here are the basic specs: Dell PowerEdge R510 with up to 12 Hot Swap HDDs,LED Intel Xeon E5649 2.53GHz, 12M Cache, 5.86 GT/s QPI, 6 core (Quantity of 2) 48GB Memory (6x8GB), 1333MHz Dual Ranked RDIMMs for 2 Processors, Optimized PERC H700 Integrated RAID Controller, 1GB NV Cache 300GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 4) 600GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 6) My first thought was to use 3 arrays. OS - Raid 1 - (2)300GB T-Log - Raid 1 (2)300GB DB - Raid 5 (5) 600GB Backup - (1) 600GB - non-raided. However, I could also do the following after purchasing one more drive for backup. OS and T-Log - Raid 10 - (4)300GB DB - Raid 10 (6)600GB The hard drive space is not an issue as the databases are not that large. I'm just trying to optimize the speed of the applications using these databases. So, what would you guys recommend?

    Read the article

  • What does Embedded SATA Controller : ATA mean?

    - by paulH
    I have a Poweredge R510 server with a PERC H700 Integrated RAID controller that is exhibiting slower than expected disk speeds (RAID 1 and RAID 10 arrays) and I'm looking at the configuration of the server. Running the command omreport chassis biossetup on the server shows me the following configuration setting: Embedded SATA Controller : ATA I can also see that the possible options for this setting are: off | ata | qdma | raid I've been looking online to find out what this setting means and what the various options refer to but I've been unable to find anything particularly helpful, so I was hoping that somebody here could help to enlighten me. Thanks, Paul.

    Read the article

  • Simultaneous read/write to RAID array slows server to a crawl

    - by Jeff Leyser
    Fairly beefy NFS/SMB server (32GB RAM, 2 Xeon quad cores) with LSI MegaRAID 8888ELP controlling 12 drives configured into 3 different arrays. 5 2TB drives are grouped into a RAID 6 array. As expected, write performance to the array is slow. However, sustained, simultaneous read/write to the array (wether through NFS or done locally) seems to practically block any other access to anything else on the controller. For example, if I do: cp /home/joe/BigFile /home/joe/BigFileCopy where BigFile is 20G, then even a simple ls /home/jane will take many 10s of seconds to complete. In addition, an ls /backup will also take many tens of seconds, even though /backup is a different array on the same controller. As soon as the cp is done, everything is back to normal. cp /home/joe/BigFile /backup/BigFile does not exhibit this behavior. It's only when doing read/write to the same array.

    Read the article

  • Best practice Raid groups for EqualLogic PS6510X

    - by 20th Century Boy
    We are thinking about purchasing 4 x EqualLogic PS6510X SANs (the Sumo boxes). Each has 48 x 600GB 10k SAS drives. They will be stacked to form a logical pool of storage (all in the same location). I understand that when you create a RAID group its done on a "per box" basis. So one box could be Raid 50, another Raid 10 etc. My question is, should I make one box a "performance" box ie Raid 10, and the other boxes "standard" ie Raid50? How do people configure their EQL arrays in the real world?

    Read the article

  • Why can't add a hot spare in freebsd? Can anybody help me fix it?

    - by hamlet
    Why can't add a hot spare? Can anybody help me fix it? mfiutil add e1:s1 mfid0 mfiutil: Drive 1 is not available My mfi status:: mfiutil show config mfi0 Configuration: 1 arrays, 1 volumes, 0 spares array 0 of 2 drives: drive 0 ( 137G) ONLINE <HITACHI HUS153014VLS300 A410 serial=JFWHSB4C> SAS enclosure 1, slot 0 drive 1 ( 137G) ONLINE <HITACHI HUS153014VLS300 A410 serial=JFWJ3AEC> SAS enclosure 1, slot 1 volume mfid0 (136G) RAID-1 64K OPTIMAL spans: array 0 mfiutil show events 1468 (boot + 25s/BATTERY/WARN) - Battery removed 1475 (boot + 52s/DRIVE/WARN) - PD 00(e1/s0) is not a certified drive 1478 (boot + 52s/DRIVE/WARN) - PD 01(e1/s1) is not a certified drive 1480 (boot + 64s/BATTERY/WARN) - BBU disabled; changing WB virtual disks to WT mfiutil show volumes mfi0 Volumes: Id Size Level Stripe State Cache Name mfid0 ( 136G) RAID-1 64K OPTIMAL Disabled

    Read the article

  • Bad disks in ancient server

    - by Joel Coel
    I have a 1998-era Netware 3.12 server that runs everything on our campus: general ledger, purchasing, payroll, student information, grades, you name it. The server has an Adaptec RAID controller with two volumes: RAID 1, 2 17GB scsi disks, Seagate ST318417W RAID 5, 3 4GB scsi disks, 2 Seagate ST34573W and 1 ST34572W. We are currently in the early stages of a project to replace this system, but you don't just jump into a new system like that and so I need to keep this server running until at least November 2011. This week we had not one but two hard drives fail. Thankfully they are from different volumes and we're able to keep running for the moment, but given the close nature of these failures I have serious doubts that I'll be able to avoid catastrophic failure from this server through the November target as is without restoring the RAID redundancy — it'll only take one more drive failure anywhere and I'm completely hosed. We are fortunate enough to have exact match "spares" lying around for both drives, but the spares are in unknown condition. I tried swapping just them in, but the RAID controller isn't smart enough to handle this and it renders the system unbootable. As for the RAID controller itself, there is utility I can get into during POST via a Ctrl-A shortcut, but I can't do much useful from there. To actually manage volumes I must first boot in to Netware, at which point I can use CI/O Array Management Software Version 2.0 to actually look at volume information. I suspect that the normal way to manage things is to boot from a special floppy with the controller software on it, but that floppy is long gone. Going through the options in the RAID software, I think the only supported way to replace a disk in an existing RAID volume is to physically add the disk, boot up and configure it as a "spare" for a volume, force the volume to use the spare to replace an existing down disk (and at this point I'm only guessing) so that the down disk becomes the spare, repair the volume, remove the spare from the volume, and then shut down and remove the disk. Then start all over for the other failed disk. All this amounts to a lot of downtime, assuming I can even make it work and that my spares are any good. As for finding reliable spares, I have no clue where to even begin looking to find a new 4GB scsi drive, or even which exact scsi system I'm looking for, as it's gone through a few different iterations over time. Another option is to migrate this to a virtual machine (hyper-v), but all previous attempts we've made in this area have failed to get very far. When this machine was installed I was just graduating from high school, and so it requires lower level knowledge of netware and dos than I ever developed, or if I did have since forgotten (I'm not exactly a dos neophyte, either). Part of my problem is this is a high-use server, and taking it down for a few days to figure things out isn't gonna fly very well. As for the question, I'm looking for anything that might be helpful in this situation: a recommendation on a place to find good spares from this era, personal experience repairing RAID volumes using a similar controller or building a hyper-v vm from an old netware server, a line on a floppy with better software for the RAID controller, recommendation on a good Novell consultant in Nebraska that would be able to put things right, a whole other option I haven't considered yet, etc. Update: For backups, we have good (recently verified via restore) backups of the data only -- nothing for the software that actually runs things. Update 2: Just a progress report that I currently have a working Netware 3.12 install in VMWare Virtual Server 2.0, thanks largely to the guide I found here: http://cerbulescubogdan.blogspot.com/2010/11/novell-netware-312-on-vmware.html The next steps are preparing empty netware volumes to match the additional volumes on my existing server, taking a dump of everything on the C:\ drive and netware volumes on my existing server, and figuring out from that information what modules need added to netware, installing my licenses (we do still have that disk, if it's any good), and moving data over. I have approval to bring the server down for a week after the first of the year (sadly not before), so, aside from creating empty volumes, the rest of the work will have to wait until then. Final Update (Jan 5, 2011): I was able to get spares working in both raid arrays without data loss this week. Both are now listed by the controller as "FAULT TOLLERANT" (yay!). I was also able to build on the progress from my last update and now have a functional "spare" server in VMWare Server 2.0. The spare can run and use our erp software, but I can't put it into production because I can't (yet) print from that box (and I have no idea why). Even so, this VM will do in a pinch if I have no other choice, and between it and the repaired RAID arrays I'm comfortable pushing on until I can junk the machine in November.

    Read the article

  • ZFS with L2ARC (SSD) slower for random seeks than without L2ARC

    - by Florian Kruse
    I am currently testing ZFS (Opensolaris 2009.06) in an older fileserver to evaluate its use for our needs. Our current setup is as follows: Dual core (2,4 GHz) with 4 GB RAM 3x SATA controller with 11 HDDs (250 GB) and one SSD (OCZ Vertex 2 100 GB) We want to evaluate the use of a L2ARC, so the current ZPOOL is: $ zpool status pool: tank state: ONLINE scrub: none requested config: NAME STATE READ WRITE CKSUM afstank ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c11t0d0 ONLINE 0 0 0 c11t1d0 ONLINE 0 0 0 c11t2d0 ONLINE 0 0 0 c11t3d0 ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c13t0d0 ONLINE 0 0 0 c13t1d0 ONLINE 0 0 0 c13t2d0 ONLINE 0 0 0 c13t3d0 ONLINE 0 0 0 cache c14t3d0 ONLINE 0 0 0 where c14t3d0 is the SSD (of course). We run IO tests with bonnie++ 1.03d, size is set to 200 GB (-s 200g) so that the test sample will never be completely in ARC/L2ARC. The results without SSD are (average values over several runs which show no differences) write_chr write_blk rewrite read_chr read_blk random seeks 101.998 kB/s 214.258 kB/s 96.673 kB/s 77.702 kB/s 254.695 kB/s 900 /s With SSD it becomes interesting. My assumption was that the results should be in worst case at least the same. While write/read/rewrite rates are not different, the random seek rate differs significantly between individual bonnie++ runs (between 188 /s and 1333 /s so far), average is 548 +- 200 /s, so below the value w/o SSD. So, my questions are mainly: Why do the random seek rates differ so much? If the seeks are really random, they should not differ much (my assumption). So, even if the SSD is impairing the performance it should be the same in each bonnie++ run. Why is the random seek performance worse in most of the bonnie++ runs? I would assume that some part of the bonnie++ data is in the L2ARC and random seeks on this data performs better while random seeks on other data just performs similarly like before.

    Read the article

  • Stop the constant random reboots of my GIGABYTE GA-B75M-D3V

    - by Frederic
    I've got some issues with a new system. It's rebooting constantly. The system consists of a: brand new: Gigabyte GA-B75M-D3V with F9 BIOS (latest) Intel Core i5-3470 Ivy Bridge 2x 8GB G.SKILL Ripjaws 1600MHz memory (mem-tested x-86) coming from a stable system: Creative Soundcard X-FI Titanium Asus Radeon HD4850 OCZ Vertex 3 120G SSD Sata 3 Hard disk 1TB Sata 2 ASUS Blu-ray Drive PSU 400w Connected peripherals : Toshiba tv (displayport on dvi of MB or HD4850) Wired mouse, wireless keyboard (logitech) Bluetooth usb key Azio main problem : it's not possible to read the errors from the MB. nothing on the manual neither on internet. At the beginning, I received a MB with graphic problems and the problem of rebooting. I RMA'd it. The new one doesn't have any graphic problems. but it's still constantly rebooting. I removed everything except the HD, the sound-card, the blu-ray drive and the wireless keyboard. It's still unexpectdly rebooting. I'm running a test with just the motherboard and the HD. I will update this text after the test. I've got some questions : Somebody have an idea of a test? The PSU could cause that problem? I used it a lot of years with the stable system. Update 1: BTW, if anyone has the same problem, the manual won't say it but you'll need to reset the bios between two tests (the screwdriver on the two pins) if you suspect a problem of compatibility .

    Read the article

  • iSCSI RAID1 on two servers, fail scenario

    - by Franz Kafka
    Hallo, a simple question: Image I have two servers, each server has two disks in RAID1. Now I merge the two arrays with iSCSI to one RAID1 disk. Two questions: Can I do the merging of the 4 disks in one go? I can't image how. First I will have to install the os, and then the raid controller is already set up to RAID1. If a whole server fails the other server would continue working without any problems? Does iSCSI notice that the other server is missing and treet this as if the two disks were broken? When the server comes back online the data is resynced, as if I installed new disks into a array? Can I image that this way? Thanks alot.

    Read the article

  • Storage product testing

    - by wildchild
    hello, I know this is out of place (being an active member here i am coming for the help from seniors) ,but i need some information regarding storage testing ,testing of Raid arrays, SCSI, SAS ,SATA and also test carried out on fabric manager(Cisco MDS series switches). I am aware that this is an administrative forum and i would really appreciate if you could direct me to the correct forum ar links where i can learn things . @ moderators-Sorry for posting at the wrong place,i would be deleting this as soon as i get the help. Thanks !

    Read the article

  • SQL Server Transaction Log RAID

    - by Eric Maibach
    We have three SQL Server servers, and each server has a about five or six databases on it. We are in the process of moving these servers to a new SAN and I am working on the best RAID configuration. Currently all of the log files for all of the databases share a RAID array, there is nothing else on this RAID array except for the log files, but all of the databases use this same array for their log files. I have read that it is best to have log files on separate disks. But in our case I am not sure whether it would be best to have one big array with about 8 drives that all the log files are on. Or would it be better to create four two disk arrays and give some of the larger databases their own dedicated disks for their log files?

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS JBODs. In addition, how does battery-backed write cache (BBWC) play into the solution?

    Read the article

  • How to perform fresh linux install while preserving software raid and user accounts

    - by slayton
    I have a system with two software raid arrays. The OS is Ubuntu 9.04 and is no longer receiving updates. I'd like to update the system to 12.04 rather than trying to do the automatic update from 9.04-> 9.10-> ... -> 12.04. My main drive has 2 partitions that are mounted at / and /home. Is it possible to do a fresh install of linux to the partition where / is mounted while preserving user accounts and preferences (such as passwords, home dir locations, etc...)? Additionally what do I need to do to keep my software raid array intact following the OS re-install?

    Read the article

< Previous Page | 124 125 126 127 128 129 130 131 132 133 134 135  | Next Page >