Search Results

Search found 6706 results on 269 pages for 'power supply'.

Page 14/269 | < Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >

  • Power button missing

    - by Christophe De Troyer
    An almost clean install of Ubuntu 13.10 keeps hiding the power button. I noticed before that my clock and power button were missing in the right top corner. I rebooted my system and they were back. Now I see my power button only is missing. How do I go about fixing this? I can't keep rebooting, can I? The latest thing I did was removing Ubuntu One: Removing Ubuntu One I don't think I did something that might've tinkered with these settings though.

    Read the article

  • Sudo Non-Password access to /sys/power/state

    - by John
    On my computer, pm-hibernate appears to be broken, however using the command echo disk > /sys/power/state appears to work perfectly. Now I just need regular user access to it, using sudo. How do I do this? The command sudo echo disk > /sys/power/state simply returns bash: /sys/power/state: Permission denied. Also, I need this in a regularly used script, how can I make it so that I don't have to type in my password for it to work???

    Read the article

  • battery icon / power indicator not shown in menu bar after upgrade to 12.04

    - by user488728
    since the upgrade from 11.10 to 12.04 the battery icon / power indicator is not shown any more in the menu bar. I went to 'system settings'--'power' and tried to set 'show battery status in menu bar' to 'always', however the selection button seems to be corrupt. Strangely, when I open the power settings dialog, the 'show battery status in menu bar' field is set to an empty string instead of showing one of the three possible choices. When I click on the small arrow next to it, the three possible choices are shown. Whatever I select, upon closing the settings dialog and reopening it, the selection field is back to empty. Please help. Thanks! HF

    Read the article

  • Can computer crashes and reboots mean weak power supply?

    - by TomA
    Recently I replaced the videocard in my PC for a newer, faster one. All games work perfectly but I get random system crashes and reboots. This happens even when the system is almost idle (browsing, playing music). It never happened with the old card. All drivers are up-to-date. Is it possible that the power supply is not powerful enough for the new card?

    Read the article

  • How much power supply does a typical PC build need?

    - by Wesley
    I am building a system for a friend. The potential specs are like this so far: ASUS A8N-VM motherboard AMD Athlon 64 3200+ @ 2.0 GHz Any 7200RPM SATA HDD Palit GeForce 8800GT 512MB GDDR3 PCIe One DVD/CD combo drive Creative SB Live! 5.1 sound card I was wondering what wattage of power supply would be able to support this hardware. I had a 350W in mind... would that do?

    Read the article

  • Blinking power button

    - by Mike Ramsey
    A friend asked me to look at his Gateway DX4640 desktop. When he presses the power button, power goes to the mobo (NVIDIA nForce 630i MCP73PV, GeForce 7100 chipset) and the CPU fan starts spinning. The power button slowely blinks on and off (blue) and the screen briefly says no signal and then goes black. And nothing else; no post code beeps. My initial two conjectures were: 1. Vista was stuck in sleep/hibernation mode, or 2. A power off had left the mobo in a bad state. The fix for both is to: a) Unplug the AC power cord b) hold the power button for 30 second to fully discharge the mobo It didn't help. I left the system unplugged from AC power for an hour. No change. I am out of ideas. Has anybody seen anything like this before? What does a blinking blue power button mean? How can I get more data points to guide trouble shooting? --Thank you, --Mike

    Read the article

  • Is the difference between superuser and serverfault basically when you can do a power cycle?

    - by wag2639
    Generally speaking, aren't there a lot of problems that can be fixed with just a simple power cycle? Especially with Windows, a reboot will solve the problems (at least temporarily)? So, would this be the difference between serverfault and superuser? Generally, where as a superuser might just be annoyed by a restart/power cycle, a sysadmin cannot because its a critical system or otherwise production box?

    Read the article

  • Integrating Oracle Hyperion Smart View Data Queries with MS Word and Power Point

    - by Andreea Vaduva
    Untitled Document table { border: thin solid; } Most Smart View users probably appreciate that they can use just one add-in to access data from the different sources they might work with, like Oracle Essbase, Oracle Hyperion Planning, Oracle Hyperion Financial Management and others. But not all of them are aware of the options to integrate data analyses not only in Excel, but also in MS Word or Power Point. While in the past, copying and pasting single numbers or tables from a recent analysis in Excel made the pasted content a static snapshot, copying so called Data Points now creates dynamic, updateable references to the data source. It also provides additional nice features, which can make life easier and less stressful for Smart View users. So, how does this option work: after building an ad-hoc analysis with Smart View as usual in an Excel worksheet, any area including data cells/numbers from the database can be highlighted in order to copy data points - even single data cells only.   TIP It is not necessary to highlight and copy the row or column descriptions   Next from the Smart View ribbon select Copy Data Point. Then transfer to the Word or Power Point document into which the selected content should be copied. Note that in these Office programs you will find a menu item Smart View;from it select the Paste Data Point icon. The copied details from the Excel report will be pasted, but showing #NEED_REFRESH in the data cells instead of the original numbers. =After clicking the Refresh icon on the Smart View menu the data will be retrieved and displayed. (Maybe at that moment a login window pops up and you need to provide your credentials.) It works in the same way if you just copy one single number without any row or column descriptions, for example in order to incorporate it into a continuous text: Before refresh: After refresh: From now on for any subsequent updates of the data shown in your documents you only need to refresh data by clicking the Refresh button on the Smart View menu, without copying and pasting the context or content again. As you might realize, trying out this feature on your own, there won’t be any Point of View shown in the Office document. Also you have seen in the example, where only a single data cell was copied, that there aren’t any member names or row/column descriptions copied, which are usually required in an ad-hoc report in order to exactly define where data comes from or how data is queried from the source. Well, these definitions are not visible, but they are transferred to the Word or Power Point document as well. They are stored in the background for each individual data cell copied and can be made visible by double-clicking the data cell as shown in the following screen shot (but which is taken from another context).   So for each cell/number the complete connection information is stored along with the exact member/cell intersection from the database. And that’s not all: you have the chance now to exchange the members originally selected in the Point of View (POV) in the Excel report. Remember, at that time we had the following selection:   By selecting the Manage POV option from the Smart View meny in Word or Power Point…   … the following POV Manager – Queries window opens:   You can now change your selection for each dimension from the original POV by either double-clicking the dimension member in the lower right box under POV: or by selecting the Member Selector icon on the top right hand side of the window. After confirming your changes you need to refresh your document again. Be aware, that this will update all (!) numbers taken from one and the same original Excel sheet, even if they appear in different locations in your Office document, reflecting your recent changes in the POV. TIP Build your original report already in a way that dimensions you might want to change from within Word or Power Point are placed in the POV. And there is another really nice feature I wouldn’t like to miss mentioning: Using Dynamic Data Points in the way described above, you will never miss or need to search again for your original Excel sheet from which values were taken and copied as data points into an Office document. Because from even only one single data cell Smart View is able to recreate the entire original report content with just a few clicks: Select one of the numbers from within your Word or Power Point document by double-clicking.   Then select the Visualize in Excel option from the Smart View menu. Excel will open and Smart View will rebuild the entire original report, including POV settings, and retrieve all data from the most recent actual state of the database. (It might be necessary to provide your credentials before data is displayed.) However, in order to make this work, an active online connection to your databases on the server is necessary and at least read access to the retrieved data. But apart from this, your newly built Excel report is fully functional for ad-hoc analysis and can be used in the common way for drilling, pivoting and all the other known functions and features. So far about embedding Dynamic Data Points into Office documents and linking them back into Excel worksheets. You can apply this in the described way with ad-hoc analyses directly on Essbase databases or using Hyperion Planning and Hyperion Financial Management ad-hoc web forms. If you are also interested in other new features and smart enhancements in Essbase or Hyperion Planning stay tuned for coming articles or check our training courses and web presentations. You can find general information about offerings for the Essbase and Planning curriculum or other Oracle-Hyperion products here (please make sure to select your country/region at the top of this page) or in the OU Learning paths section , where Planning, Essbase and other Hyperion products can be found under the Fusion Middleware heading (again, please select the right country/region). Or drop me a note directly: [email protected] . About the Author: Bernhard Kinkel started working for Hyperion Solutions as a Presales Consultant and Consultant in 1998 and moved to Hyperion Education Services in 1999. He joined Oracle University in 2007 where he is a Principal Education Consultant. Based on these many years of working with Hyperion products he has detailed product knowledge across several versions. He delivers both classroom and live virtual courses. His areas of expertise are Oracle/Hyperion Essbase, Oracle Hyperion Planning and Hyperion Web Analysis.  

    Read the article

  • WebCenter Customer Spotlight: Los Angeles Department of Water and Power

    - by me
    Author: Peter Reiser - Social Business Evangelist, Oracle WebCenter  Solution Summary Los Angeles Department of Water and Power (LADWP) is the largest public utility company in the United States with over 1.6 million customers. LADWP provides water and power for millions of residential & commercial customers in Southern California. The goal of the project was to implement a newly designed web portal to increase customer self-service while reducing transactions via IVR and automate many of the paper based processes to web based workflows for their 1.6 million customers. LADWP implemented a Self Service Portal using Oracle WebCenter Portal & Oracle WebCenter Content and Oracle SOA Suite for the integration of their complex back-end systems infrastructure. The new portal has received extremely positive feedback from not only the customers and users of the portal, but also other utilities. At Oracle OpenWorld 2012, LADWP won the prestigious WebCenter innovation award for their innovative solution. Company OverviewLos Angeles Department of Water and Power (LADWP) is the largest public utility company in the United States with over 1.6 million customers. LADWP provides water and power for millions of residential & commercial customers in Southern California. LADWP also bills most of these customers for sanitation services provided by another department in the city of Los Angeles.  Business ChallengesThe goal of the project was to implement a newly designed web portal that is easy to navigate from a web browser and mobile devices, as well as be the platform for surfacing internet and intranet applications at LADWP. The primary objective of the new portal was to increase customer self-service while reducing the transactions via IVR and walk-up and to automate many of the paper based processes to web based workflows for customers. This includes automation of Self Service implemented through My Account (Bill Pay, Payment History, Bill History, Usage analysis, Service Request Management) Financial Assistance Programs Customer Rebate Programs Turn Off/Turn On/Transfer of Services Outage Reporting eNotification (SMS, email) Solution DeployedLADWP implemented a Self Service Portal using Oracle WebCenter Portal & Oracle WebCenter Content. Using Oracle SOA Suite they integrated various back-end systems including Oracle Siebel CRM IBM Mainframe based CIS FILENET for document management EBP Eletronic Bill Payment System HP Imprint System for BillXML data Other systems including outage reporting systems, SMS service, etc. The new portal’s features include: Complete Graphical redesign based on best practices in UI Design for high usability Customer Self Service implemented through MyAccount (Bill Pay, Payment History, Bill History, Usage Analysis, Service Request Management) Financial Assistance Programs (CRM, WebCenter) Customer Rebate Programs (CRM, WebCenter) Turn On/Off/Transfer of services (Commercial & Residential) Outage Reporting eNotification (SMS, email) Multilingual (English & Spanish) – using WebCenter multi-language support Section 508 (ADA) Compliant Search – Using WebCenter SES (Secured Enterprise Search) Distributed Authorship in WebCenter Content Mobile Access (any Mobile Browser) Business ResultsThe new portal has received extremely positive feedback from not only customers and users of the portal, but also other utilities. At Oracle OpenWorld 2012, LADWP won the prestigious WebCenter innovation award for their innovative solution. Additional Information LADWP OpenWorld presentation Oracle WebCenter Portal Oracle WebCenter Content Oracle SOA Suite

    Read the article

  • Cross compilation of udns for power pc

    - by pragya
    I have libraries of x86 architecture that I want to cross compile for power pc. I have already cross compiled different libraries for power pc by setting environment variables for powerpc and using appropriate options with ./configure. Now, I want to cross compile libudns for powerpc. In ./configure --help I am not getting those appropriate options to cross compile. For libudns, I set environment variables for powerpc and ran ./configure but it throws following error: configure: fatal: $CC (powerpc-linux-gnu-gcc) is not a working compiler

    Read the article

  • Visual Studio 2010: Pro Power Tools

    - by Enrique Lima
    There is a set of Pro Power Tools released yesterday for Visual Studio 2010.  Check them out here. Brian Harry did a feature summary description on his blog.  Check it out here: http://blogs.msdn.com/b/bharry/archive/2010/06/07/announcing-the-first-visual-studio-pro-power-tools.aspx

    Read the article

  • Solving security issue in PowerPivot for SharePoint and Power View

    - by Marco Russo (SQLBI)
    I just installed a brand new server (well, a virtual machine) with SharePoint 2010 SP1 and SQL Server 2012 RC0, including PowerPivot and Reporting Services / Power View. The server is joined to the domain I use in our development environment. I published a workbook in the PowerPivot Gallery and my user was immediately able to connect, browse and navigate data of the Excel workbook published by SharePoint. Moreover, I was able to open it in Power View. However, other users failed the connection. After...(read more)

    Read the article

  • Unsafe shutdown on power button press (Ubuntu Server 13.10)

    - by Sam Bloomberg
    I have Ubuntu Server 13.10 set up on a machine, and whenever I press (not press and hold) the power button the machine doesn't safely shutdown (it instantly powers off), though it does flash the message "acpid: exiting" before turning off. If I instead run shutdown -h now, it goes through the usual cycle of stopping processes, unmounting filesystems, etc... Any ideas why this might be? I want the power button to safely shut down the system (unless I hold it down, of course).

    Read the article

  • New power supply and now HDDs are not recognized.

    - by Michael
    So I upgraded to a new X4 ULTRA power supply that was recommended to me by a local TigerDirect store. After installing it along with a new liquid cooling system, I booted it up and it automatically fried my CD Drive. After that I noticed that the OS wouldn't start and figured out that none of the 4 HDDs in my computer were being recognized by the BIOS. I feel them spool at a steady pace and have tried new cables and connections but to no avail. I triple checked all of the connections and cables and have no idea what is wrong. This isn't the first time I changed a PS or CPU cooling system but I am at a dead end. Any ideas, aside from buying a USB HDD reader and seeing if they are all fried? Also, this is a stock Gateway mobo with the mobo USB connections already dead. Could the new PS have fried the SATA connections??

    Read the article

  • Why would a machine ruin three "power supply"s?

    - by Moshe
    A client of mine has an XP era eMachines. The power supply has died and been replaced 3 times. I've discharged the motherboard and checked the surge protector. In the middle of a scan with ComboFix, the machine died. It powers on and hangs before the BIOS and shows a solid yellow light. I believe the model # is T5062 or something like that. Aside from a bad outlet, what would cause the PSU to die a few times?

    Read the article

  • Bios wont post unless I restart power supply.

    - by remy
    I have an annoying problem with a computer. The BIOS wont post after it has been turned off and started again unless I turn the switch off/on on the power supply. The fans, cdrom hdd and everything starts running but the bios never beeps and the monitor stays black. I HAVE TRIED: reinstalling windows xp, flashed bios to latest, cmos clear, new power supply, other hdd, new memory sticks, graphics card. I also removed the motherboard from the computer case and laid it on a cardboard box and only connected the PSU, RAM and CPU. Other than this the computer works great but its annoying having to off/on the power supply switch before turning it on after its been off. My guess is that the motherboard is faulty but I would just like to hear what you guys think. Sorry for my english / Remy

    Read the article

  • Big noise from Power Supply Unity Fa? Should I replace it immediately?

    - by EApubs
    Recently, I started to get a large noise from my PC when switched on. After some time, it disappears. I discovered that the issue is with the Power Supply Unit. Does this mean I have a failing PSU? Will it harm the PC if I didn't replace it immediately? Several years ago I bought a new computer casing which is very weird. Its small and compact. Normally, we have the PSU in the top. But in here, the PSU is on the bottom and right below the hard drive. Recently, two of my hard drives started to show problems. Read errors and bad sectors. Can it be the PSU and the design of the casing? Here's an image of the PSU and the hard drive :

    Read the article

  • New power supply, now computer doesn't recognise hard drive?

    - by Mike
    Ok, I bought a new power supply, because my old one was too damn loud. I hooked it up to my PC, turned it on, everything is looking fine, start up detects my DVD drive, 2 hard disks.. then I get the message "BOOT FAILURE INSERT SYSTEM DISK". Now I've seen some other people talk about going into BIOS and changing the start up to the HDD and not the CD.. well I've done that and it doesn't help. If I let windows load up and it asks me to which partition I wish to install windows, no partition is present. It's as if after the initial start up the drives arn't being found. I plugged my old (but loud) PSU back in, connected up all the cables, and it works perfectly. Why does the new PSU not detect my HDD's after the first BIOS screen start up? Any ideas? :)

    Read the article

  • No power save on external hard drive - How to implement?

    - by blastawaythewall
    I recently bought a new 3.5" USB external hard drive which I thought had a power save feature on it, but it turns out that it doesn't. So whether it's being used or not, it spins, which wouldn't be a problem if it wasn't so loud and didn't get really really hot. After doing some research, it seems like what controls this is the enclosure of the hard drive and not the drive itself or the OS (although I suspect that's not entirely true). I attempted to use the "hdparm" utility but it couldn't identify my externals. Just to be clear, I'm defining power save as a hard drive spinning down after a certain time period of not being used (read from/written to). Also, I have other externals that do this, so it's not a problem from my computer. Here's my question: Is there a way to implement a power save-like feature on my hard drive through software, OS settings, or anything else? Here's some details: Running: Windows XP Home SP2 HD Model: Cavalry CAUM-B-OTB 2TB (although the website only lists 1TB max) Inside: Hitachi Deskstar 7K2000 (HDS722020ALA330) (I would link, but new users can only post 1) Thanks in advance.

    Read the article

  • Motherboard HDDPWR1 connector

    - by Eric Leschinski
    I need help identifying the name of a connector. I have a Gateway DX4870-UB318 computer, I opened the case and wanted to attach another hard drive, but to my surprise one existing SATA hard drive was connected to the motherboard with this connector: And here is the spot on the Motherboard where the power was supplied. What is the name of this adapter and where can I get another one? Clues: This computer was bought new October 2013 from best buy, box number: DX4870-UB318. The gateway folks won't divulge the type of motherboard it has nor give specs on it. On the wire itself is an identification code: H.35090NJ01-000 Next to the connector on the motherboard it says: HDDPWR1 and the second one says HDDPWR2. This cable has two SATA power connectors and one mystery connector. The power supply has no molex power cables and no SATA power connectors! This is the most bizarre hard drive power system I've seen. I guess the motherboard folks are trying to remove the burden for desktop power supplies to provide adapters (molex, SATA, other) to CD's and hard drives. Can someone put a name on that white flat 6 pin HDD Power Connector? My Solution I can buy a "SATA Power Y Splitter Cable" to provide more spaces to power sata devices.

    Read the article

  • I can't get my PC to start up by a normal way.

    - by ssice
    I couldn't write a more accurate title. I am just unable to start the computer by pressing the Power On button. I checked the Power Supply and it seems to give good voltage values in every pin. And this is not a BIOS malfunction because of bad overclocking or anything that may come to your mind. And I will tell you why. It happens that EPS (or any ATX-based) power supply has the ability to be powered-on by the Motherboard by jumping the 13th pin of the 24-pin-ATX-connector to COM/GND. I did it, after pushing the power on button (without any visual response) and, pwhaa! The machine turned on. I was able to read (and even write, if I wanted) BIOS values and then start any OS installed. Machine starts, so it's not any kind of misconfiguration. It seems some hardware related. I am able to power the machine on only if I already pushed the power on button. Though pushing it without jumping the 13th pin to ground for a second does not power the machine. Of course, jumping the pin without pushing the power on button does not tell the motherboard anything, so the computer would not start up either. It's as if the logic that connects the power button with the 13th pin derivation to GND was unable to be activated. What can be the issue? How can I solve it? My configuration is as follows: CPU: AMD Phenom 9850 X4 Black Edition MB: ASUS Formula II AM2 RAM: 2x2GB Corsair Dominator 5-5-5-15 2T @ 1066MHz DDR2 Tested also with only 1 module GPU: 2x XFX nVIDIA GeForce 9600 GT XxX Alpha Dog Edition @ Core: 540Mhz [SLi] Power Supply: Xilence 700W (ATX 12V 2.3 / EPS 12V 2.92 compatible) PS: I know the machine is like 2 years old. I hardly use it now, but my parents do.

    Read the article

< Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >