Search Results

Search found 5380 results on 216 pages for 'primary'.

Page 155/216 | < Previous Page | 151 152 153 154 155 156 157 158 159 160 161 162  | Next Page >

  • Will adding a SSD cache device to my ZFS storage improve performance?

    - by Sysadminicus
    The server has 4GB of RAM and my zpool is made up of 15.5k SAS drives arranged like this: NAME STATE READ WRITE CKSUM tank ONLINE 0 0 0 raidz1-0 ONLINE 0 0 0 c0t2d0 ONLINE 0 0 0 c0t3d0 ONLINE 0 0 0 c0t4d0 ONLINE 0 0 0 c0t5d0 ONLINE 0 0 0 c0t6d0 ONLINE 0 0 0 c0t7d0 ONLINE 0 0 0 c0t8d0 ONLINE 0 0 0 raidz1-1 ONLINE 0 0 0 c0t10d0 ONLINE 0 0 0 c0t11d0 ONLINE 0 0 0 c0t12d0 ONLINE 0 0 0 c0t13d0 ONLINE 0 0 0 c0t14d0 ONLINE 0 0 0 spares c0t9d0 AVAIL c0t1d0 AVAIL The primary use is as an NFS store for a couple VMWare ESXi servers. I can't do any "true" benchmarks because this is a production system (no budget for test systems), but using dd and bonnie++ I can't get more than ~40-50MB/s writes and ~70-90MB/s reads. It seems I should be able to do much better, but I'm not sure where to optimize. Based on what I've read, I think dropping in a OCZ Vertex 2 Pro SSD as my L2ARC is going to be the best bang-for-the-buck to improve througput. Is there something else I should be looking into to help performance? If not... How do I know how big a cache device I need? Am I safe with only a single SSD as my cache device?

    Read the article

  • W2K INACCESSIBLE_BOOT_DEVICE, with System Commander

    - by Gary Kephart
    I have a system that was originally had Win NT. I added System Commander (SC7) and then added W2K. The relevant partitions are: 0 - Primary - MultiFAT (Has Win NT, mapped to C:) 1 - Extended - with many logical partitions: 1.1 NTFS which has W2K and is mapped to D: 1.2 other logical partitions which are irrelevant to this D: was getting full. It needed room for virus definitions and Windows upgrades. In the past, I had simple used SC7 to resize D: without problems. So I did it again this time. However, upon finishing, I got the message "Unable to create partition". It also marked the partition as unformatted. I checked that the files on the disk were still there using SC7's Partition Explorer, and they were there. I continued and the system managed to boot up fine anyways. Then I rebooted the system again. This time, I got a message saying "INACCESSIBLE_BOOT_DEVICE". I went back in to SC7 and to Partition Commander, and it was still saying that the partition was unformatted but the Partition Explorer still showed the files on the system. I finally decided to resize the partition again, figuring that this would force a rewrite of the partition information. That seemed to work, until I had to reboot again. Now I can't see the files using Partition Explorer, and the Resize button is now disabled. What now?

    Read the article

  • How to achieve the following RTO & RPO with logshipping only using SQL Server?

    - by Jimmy Chandra
    Trying to come up with viable backup restore & logshipping solution for achieving the following: 15 minutes Recovery Point Objective (no more than 15 minutes data loss at any time) 5 minutes Recovery Time Objective (must be able to get the db up and running back by 5 minutes) Considering using logshipping only (which I think is kind of pushing it, but I want to know if anyone else know how to achieve this). Some other info for consideration: Using 40 Gbit / sec fiber channel between the primary and disaster recovery (DRC) sites The sites are about 600 km apart. At close of business, the amount of data generated is predicted to be about 150 MB/sec. Log backup is planned for every 5 min. Doing some rough calculation I came up w/ the following numbers: 40 Gbit / sec = 5 MB / sec @ 100% network efficiency. 5 MB / sec = 300 MB / min. @ 300 MB / min, the total amount of data that can be transfer considering the 5min RTO is about 1.5GB, but that will left no time for the actual backup and restore, so if we cut it down to 3min logshipping time, which equals to ~900 MB over 3 minutes at 100% network efficiency, that will left about 1 min backup time and 1 minute restore time. Currently don't have any information if the system being used is capable of restoring 900 MB in 1 min, but assume it can. for COB scenario... 150 MB/sec, and considering the 3 min logshipping time, which should equal to about 27 GB of data over 3 mins...??? I think this is where the SLA will break... since there is no way to transfer 27 GB of data over a 40Gbit/sec line in 3 min. Can I get someone else opinion? I am thinking database mirroring might be a better answer for this...

    Read the article

  • XP Client for NFS failure dialog on startup, but drive mapping works

    - by Matt Bennett
    I'm mounting an NFS share to some windows machines using the tools that come in the Services for UNIX Administration toolkit. I've set up the User Name Mapping service to use local passwd and group files. I had to manually start the User Name Mapping service, and then created an 'advanced map' from the XP machine's user to a uid that exists in on my NFS server, like so: Windows User: Matt Bennett UNIX Domain: PCNFS UNIX User: mattbennett UID: 10250 Primary: * I can map a network drive without any issues, and it correctly identifies the UID and GID to use, but when I reboot I get this message: "An error occurred while connecting to the NFS server. Make sure that the Client for NFS service has started. If the problem persists make sure Client for NFS service can communicate with User Name Mapping or PCNFS server." After dismissing the dialog, the machine finishes booting and the network drive is there in My Computer with the title "Disconnected Network Drive", but I can open it I can see the network share without a problem, and then it drops the 'disconnected' from its title. It seems like the services are starting in the wrong order or something, so the first attempt to connect fails but subsequent ones work as expected. There don't seem to be any symptoms apart from the dialog box, but obviously something's not quite right. What have I done wrong? Thanks, Matt.

    Read the article

  • Can't ping my Window 7 machine from within a Windows XP virtual machine

    - by Jonathan Conway
    I have Windows 7 installed as my primary operating system, on a laptop that's on my home network (wireless). I'm using Microsoft Virtual PC 2007 SP1 to run a virtual machine of Windows XP SP3, in which I want to access the Windows 7 instance, both to browse a shared folder and access the local Apache server. So far I can ping my Windows 7 IP address (IPv4) and access the apache server through the web browser through HTTP. However using my machine name never seems to work. Pinging it fails, and I can't access my apache server using it either. The problem seems to be something to do with my machine's name being registered under IPv6 rather than IPv4. I'm at a loss what to do. Should I try to set up IPv6 on the virtual machine? Not sure how to go about that. Or maybe I should somehow get my machine name on Windows 7 to work with IPv4? Although I think it already does, because I can ping it from a separate box (running Ubuntu), which is only registered under IPv6.

    Read the article

  • LSI MegaRAID LINUX got Optimal after degradation but strange POST message

    - by kesrut
    Linux server box with LSI MegaRAID controller got degraded. But after some time RAID status changed to Optimal. Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 2.727 TB Mirror Data : 2.727 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 3 Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No But now I'm getting RAID BIOS POST message: Your battery is either charging, bad or missing, and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs willl actually run in write-through mode until the battery is fully charged or replaced if it is bad or missing. (Image: http://cl.ly/image/1h1O093b1i2d) So may it be battery issue caused problem ? I get information about battery: BatteryType: iBBU Voltage: 4001 mV Current: 0 mA Temperature: 22 C Battery State : Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No Where can be problem ? I'm disabled alarms, but get them if enabled. But don't know how find root of problem.

    Read the article

  • Trying to use a SmartHost with my Exchange 2010 server

    - by Pure.Krome
    Hi folks, I'm trying to use a SmartHost with my Exchange 2010 Server. SmartHost details: Secure SMTPS: securemail.internode.on.net 465 <-- Note: that's port 465 Configure your existing SMTP settings (in your email program) to: use authentication (enter your Internode username and password, enter your username as [email protected]). enable SSL for sending email (SMTPS). So I've added the smart host details to my Org Config -> Hub Transport. I then used PowerShell to add the port:- Set-SendConnector "securemail.internode.on.net" -port 465 I've then added my username/password (as suggested above) to the SmartHost as Basic Authentication (with no TLS). Then I try sending an email and I get the following error message :- 451 4.4.0 Primary target IP address responded with: "421 4.4.2 Connection dropped due to ConnectionReset." So i'm not sure how to continue. I also tried ticking the TLS box but stll I get the same error. If i don't use SMTPS (secure SMTP, on port 465) and use basic SMTP on port 25 with no Authentication, email gets sent. Any ideas? EDIT: Btw, I can telnet to that server on port 465 from my mail server .. just to make sure i'm not getting firewall'd, etc.

    Read the article

  • How do I get "Back to My Mac" (using MobileMe) from Windows?

    - by benzado
    I have a MobileMe subscription and a Mac at home with "Back to My Mac" enabled. When I'm away from home, this service lets me use another Mac to connect to my Mac back home and access file sharing, screen sharing, etc. As far as I know, the service doesn't use any proprietary protocols, so in theory I should also be able to get "Back to My Mac" from a Windows PC. This MacWorld article explains how it works. Basically, it uses Wide-Area Bonjour to give your Mac a domain name like hostname.username.members.mac.com. Remote computers can find your Mac using that address, then connect to it using a private VPN. The "Wide Area Bonjour" part seems to make it a little more complicated than simply a regular domain name, though. Note that I'm not interested in using the methods described by LifeHacker, which doesn't use the MobileMe service at all. I don't want to use a totally different dynamic DNS service. I'd like to use the one I'm already paying for, or at least find out why that's not possible from Windows. Also, my primary problem is finding a network route back to my mac... once I've got that I know how to enable services so that Windows can talk to it. UPDATE: Based on some additional research, it appears that Apple is only assigning IPv6 addresses to the hostname.username.members.mac.com names. So any solution will require enabling IPv6 support on Windows, if possible.

    Read the article

  • adding or routing additional domain email addresses

    - by Mustafa Ismail Mustafa
    We have exchange 2007 and we bought a new domain name and we're still keeping the old one so that we can wean everyone off of the old emails. Now, I'm wondering how to go about this. I need to add the new domain as accepted and authoritative by the exchange server. Emails on the new domain need to get routed to the inbox and ditto the old emails, however, I want to be able to change the reply-to in the header to the new email address automatically. I also want to set the new email addresses as the defaults. Ideally, I'd like to be able to add a message at the bottom of every externally outgoing email saying that the new email is [email protected]. But this is a nice to have, certainly not a must have. I've added the new domain as authoritative, and managed to change the primary smtp email addresses to the new one, but sent emails are not being routed to them and neither are the old email addresses! Now how the heck would I go about fixing all of that? I'm completely stumped! TIA

    Read the article

  • Avoiding DNS timeouts when a dns server fails

    - by Neil Katin
    We have a small datacenter with about a hundred hosts pointing to 3 internal dns servers (bind 9). Our problem comes when one of the internal dns servers becomes unavailable. At that point all the clients that point to that server start performing very slowly. The problem seems to be that the stock linux resolver doesn't really have the concept of "failing over" to a different dns server. You can adjust the timeout and number of retries it uses, (and set rotate so it will work through the list), but no matter what settings one uses our services perform much more slowly if a primary dns server becomes unavailable. At the moment this is one of the largest sources of service disruptions for us. My ideal answer would be something like "RTFM: tweak /etc/resolv.conf like this...", but if that's an option I haven't seen it. I was wondering how other folks handled this issue? I can see 3 possible types of solutions: Use linux-ha/Pacemaker and failover ips (so the dns IP VIPs are "always" available). Alas, we don't have a good fencing infrastructure, and without fencing pacemaker doesn't work very well (in my experience Pacemaker lowers availability without fencing). Run a local dns server on each node, and have resolv.conf point to localhost. This would work, but it would give us a lot more services to monitor and manage. Run a local cache on each node. Folks seem to consider nscd "broken", but dnrd seems to have the right feature set: it marks dns servers as up or down, and won't use 'down' dns servers. Any-casting seems to work only at the ip routing level, and depends on route updates for server failure. Multi-casting seemed like it would be a perfect answer, but bind does not support broadcasting or multi-casting, and the docs I could find seem to suggest that multicast dns is more aimed at service discovery and auto-configuration rather than regular dns resolving. Am I missing an obvious solution?

    Read the article

  • Increasing Java's heapspace in Tomcat startup script

    - by Ankur
    I want to increase my heap size when using Tomcat. I was told to add this line export CATALINA_OPTS=-Xms16m -Xmx256m; In to the startup.sh script - I did so (at the beginning) but got the error export: 24: -Xmx256m: bad variable name Where am I supposed to add it, am I doing something else wrong? <b>export CATALINA_OPTS=-Xms16m -Xmx256m;</b> # Better OS/400 detection: see Bugzilla 31132 os400=false darwin=false case "`uname`" in CYGWIN*) cygwin=true;; OS400*) os400=true;; Darwin*) darwin=true;; esac # resolve links - $0 may be a softlink PRG="$0" while [ -h "$PRG" ] ; do ls=`ls -ld "$PRG"` link=`expr "$ls" : '.*-> \(.*\)$'` if expr "$link" : '/.*' > /dev/null; then PRG="$link" else PRG=`dirname "$PRG"`/"$link" fi done PRGDIR=`dirname "$PRG"` EXECUTABLE=catalina.sh # Check that target executable exists if $os400; then # -x will Only work on the os400 if the files are: # 1. owned by the user # 2. owned by the PRIMARY group of the user # this will not work if the user belongs in secondary groups eval else if [ ! -x "$PRGDIR"/"$EXECUTABLE" ]; then echo "Cannot find $PRGDIR/$EXECUTABLE" echo "This file is needed to run this program" exit 1 fi fi exec "$PRGDIR"/"$EXECUTABLE" start "$@"

    Read the article

  • Defeating the RAID5 write hole with ZFS (but not RAID-Z) [closed]

    - by Michael Shick
    I'm setting up a long-term storage system for keeping personal backups and archives. I plan to have RAID5 starting with a relatively small array and adding devices over time to expand storage. I may also want to convert to RAID6 down the road when the array gets large. Linux md is a perfect fit for this use case since it allows both of the changes I want on a live array and performance isn't at all important. Low cost is also great. Now, I also want to defend against file corruption, so it looked like a RAID-Z1 would be a good fit, but evidently I would only be able to add additional RAID5 (RAID-Z1) sets at a time rather than individual drives. I want to be able to add drives one at a time, and I don't want to have to give up another device for parity with every expansion. So at this point, it looks like I'll be using a plain ZFS filesystem on top of an md RAID5 array. That brings me to my primary question: Will ZFS be able to correct or at least detect corruption resulting from the RAID5 write hole? Additionally, any other caveats or advice for such a set up is welcome. I'll probably be using Debian, but I'll definitely be using Linux since I'm familiar with it, so that means only as new a version of ZFS as is available for Linux (via ZFS-FUSE or so).

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • Running a VM off a USB 2.0 Flash Drive - Mac/Parallels/XP

    - by geerlingguy
    I use a MacBook Air as my primary machine, and the 128GB SSD means space is precious. To save about 10 GB, I've been running Parallels with a Windows XP VM off an external USB hard drive, which performs as well in everyday use as running the VM off the internal SSD. So, I bought a tiny 32GB USB 2.0 flash drive, plugged it into the MacBook Air, formatted it first as ExFAT (which was slow), then as Mac OS Extended (Journaled) (which was also slow), and copied over my VM file, and ran Parallels off it. My full experience is documented here: http://www.midwesternmac.com/blogs/jeff-geerling/running-windows-xp-vm Straight file copies are really fast — 30 MB/sec read (solid the whole time), and 10-11 MB/sec write (solid the whole time). But I noticed that once XP started running, the disk access rates were in the low KB ranges. Are USB flash drives really that poor at random access, or could I possibly be missing something (the format of the flash drive, etc.?)? Of note, I've tried the following, to no great effect: Formatting the drive as either ExFAT or Mac OS Extended (Journaled) Unplugging all other USB devices and turning off Bluetooth (which runs on the right-side-port USB bus). Plugging in the flash drive either direct in the right side port, or the left side port, or into a USB 2.0 hub

    Read the article

  • DNS, subdomain, and IPv6 -- possible to add subdomain.example.com NS record to an IPv6 host?

    - by mpbloch
    example.com is listed with a registrar -- specifically, answerable.com. I want to host a subdomain in-house, specifically home.example.com. I am using an ipv6 gateway, specifically gogo6, to have a public IPv6 address. The IP address looks like 2001:xxxx:xx47. Then http://[2001:xxxx:xx47] goes to my test site (an instance of IIS7). I can add a quad-A record for my primary site -- home.example.com AAAA 2001:xxxx:xx47. Then http//home.example.com loads correctly. Must I add an A or quad-A record for all sub.home.example.com to my answerable.com DNS manager for example.com? Or can I delegate DNS queries to *.home.example.com to the machine at [2001:xxxx:xx47]? I have tried to add a AAAA record for tunnel.example.com to [2001:xxxx:xx47], and then add an NS entry for home.example.com to tunnel.example.com, but browsing then results in "DNS lookup error" from my browser. Is this a configurable scenario? Can DNS for subdomain only be delegated to IPv4 addresses?

    Read the article

  • Firefox 29 - how do I delete history entries visited fewer than x times

    - by lousyuser
    Context: I've been using my Firefox profile for a couple of years now. My history file has become huge, naturally. I got Firefox Sync set up between my main desktop PC and my laptop. HW configs: PC: i5-3450, 8 GB DDR3 RAM, Crucial M4 128 GB SSD laptop: Pentium SU4100, 4 GB DDR3 RAM, WD 5400 rpm HDD Accessing history entries when typing into the Awesome Bar on my desktop takes quite a long time despite the decent config, the laptop is even slower. The experience is quite unresponsive. I figured if I cleared the history up a little bit, I might avoid creating a new profile to speed things up. The question itself: to illustrate: Is there a way to delete all history entries that have been visited fewer than x (let's say 5) times and at the same time the recent visit is fewer than y (let's say 120) days old? afaik the history file is some kind of SQL database, but I'm not really sure how the data is saved, if there's a "safe way" to edit it and what the query to do what I need would look like. Thanks in advance for any help. I kept browsing through previous SuperUser questions to see if I could find relevant information. "In my Firefox profile directory, there is a filed named places.sqlite. Opening it with sqlite reveals (amongst others) the tables moz_places and moz_historyvisits. It seems that moz_historyvisits uses the primary of moz_places to refer to the URLs." As I'm unfamiliar with databases, I don't really understand the way the two tables mentioned in the quote are related. screenshot of a part of the tables I've noticed the visit_count is in a standard format, making it easy to work with. The last_visit_date looks encrypted to my naked eye, but I can't see in which way. Hope that helps, I'm at my wits' end.

    Read the article

  • Use Mac OS X Server As Development Environment

    - by macinjosh
    I've installed Mac OS X Server 10.6.3 on my laptop to use as my normal OS. I do a lot of web development and thought it would be handy to run OS X Server so I could more easily manage my local development environment (Apache Virtual Hosts, Hostnames for each local site, etc). I'm really enjoying the new setup except for one problem. DNS. My ideal situation would be to add a site (some-site.local) in the Web Service and then go to the DNS Service and add a primary record for the new site. I actually got this working at one point but after a reboot it stopped working! The records look the same as they did before the reboot but the site doesn't come up in Safari. Here is a list of my needs: Need to be able to add new domains at a whim Domains always map to a site on the same box's Web Service Local & External IPs often change It would nice if it worked on any network (i.e. WiFi at the airport or coffee shop) Sites only need to be accessible locally Configuration should stay put even after rebooting I've done some googling and used this as a bit of guide. In the past I've used MAMP and then just a local Apache/PHP/MySQL install with a manually managed hosts file. I'd rather not go back.

    Read the article

  • VMWare Guest Info - Wrong IP Returned

    - by Jon Bailey
    We're running a VDI environment with vSphere 4.0 and Oracle VDI 3.2.2 and are having a bit of a problem with users that connect to an IPSec VPN from within their VM. For some reason, once connected to the VPN, the VMWare API returns GuestInfo.ipAddress as the VPN IP rather than the primary IP of the only NIC on the system. The IP address shown in net[0].ipAddress is the correct address and is what vSphere client is reporting. Is there any way to get VMWare tools to report the net[0].ipAddress as GuestInfo.ipAddress? Below is sample output from the guestinfo.pl script. 172.16.1.2 is the example "bad" VPN address that our VDI software is seeing. VMXFLEX01 guestFamily: windowsGuest VMXFLEX01 guestFullName: Microsoft Windows XP Professional (32-bit) VMXFLEX01 guestId: winXPProGuest VMXFLEX01 guestState: running VMXFLEX01 hostName: VMXFLEX01 VMXFLEX01 ipAddress: 172.16.1.2 VMXFLEX01 toolsStatus: VMware Tools is running and the version is current. VMXFLEX01 toolsVersion: 8194 VMXFLEX01 Screen - Height: 600 VMXFLEX01 Screen - Width: 800 VMXFLEX01 Disk[0]: Capacity 42935926784 VMXFLEX01 Disk[0]: Path : C:\ VMXFLEX01 Disk[0]: freespace : 33272619008 VMXFLEX01 net[0] - connected : 1 VMXFLEX01 net[0] - deviceConfigId : 4000 VMXFLEX01 net[0] - macAddress : 00:50:56:95:1f:c9 VMXFLEX01 net[0] - network : VM Network VMXFLEX01 net[0] - ipAddress : 10.0.0.2

    Read the article

  • How do I connect a 2008 server to a 2003 server active directory?

    - by Matt
    Our DC is running Windows Server 2003. I've just set up Windows Server 2008 and have terminal server running on it. When setting the terminal server permissions, it was able to allow a group name that was read from the domain. In the DC the new terminal server shows up as a computer in the domain. I can also log in as a user within the domain even though that user doesn't exist locally on the new server. However, when I go to set sharing permissions on the new machine it doesn't show my domain as a location. Instead it is only looking at location "machinename" and not allowing domain to be seen or added. Is there something I'm missing? Ok, lots of errors in the event log. We have this: The winlogon notification subscriber is taking long time to handle the notification event (Logon). Followed by this: The winlogon notification subscriber took 121 second(s) to handle the notification event (Logon). Followed by: The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain controller and Group Policy has succesfully processed. If you do not see a success message for several hours, then contact your administrator. I think this might be the same problem I'm having http://serverfault.com/questions/24420/primary-domain-controller-slow Solved. The issue was that I had changed from DHCP to static and put the wrong DNS server IP in. i.e. firewall instead of DC/DNS server.

    Read the article

  • postgresql deleteing old tables

    - by BB
    I have a postgresql database which stores my radius connection information. What I want to do is only store a months worth of logs. How would I craft a sql statement that I can run from cron that would go and delete and rows that where older then a month? Format of the date in the table. that date is taken from acctstoptime collum Date format 2010-01-27 16:02:17-05 Format of the table in question. -- Table: radacct -- DROP TABLE radacct; CREATE TABLE radacct ( radacctid bigserial NOT NULL, acctsessionid character varying(32) NOT NULL, acctuniqueid character varying(32) NOT NULL, username character varying(253), groupname character varying(253), realm character varying(64), nasipaddress inet NOT NULL, nasportid character varying(15), nasporttype character varying(32), acctstarttime timestamp with time zone, acctstoptime timestamp with time zone, acctsessiontime bigint, acctauthentic character varying(32), connectinfo_start character varying(50), connectinfo_stop character varying(50), acctinputoctets bigint, acctoutputoctets bigint, calledstationid character varying(50), callingstationid character varying(50), acctterminatecause character varying(32), servicetype character varying(32), xascendsessionsvrkey character varying(10), framedprotocol character varying(32), framedipaddress inet, acctstartdelay integer, acctstopdelay integer, freesidestatus character varying(32), CONSTRAINT radacct_pkey PRIMARY KEY (radacctid) ) WITH (OIDS=FALSE); ALTER TABLE radacct OWNER TO radius; -- Index: freesidestatus -- DROP INDEX freesidestatus; CREATE INDEX freesidestatus ON radacct USING btree (freesidestatus); -- Index: radacct_active_user_idx -- DROP INDEX radacct_active_user_idx; CREATE INDEX radacct_active_user_idx ON radacct USING btree (username, nasipaddress, acctsessionid) WHERE acctstoptime IS NULL; -- Index: radacct_start_user_idx -- DROP INDEX radacct_start_user_idx; CREATE INDEX radacct_start_user_idx ON radacct USING btree (acctstarttime, username);

    Read the article

  • Dual boot windows 8 pro and windows 7 on XPS 8500 Special Edition

    - by Jesse
    I am trying to install a dual boot with windows 7 premium and windows 8 Pro on an XPS 8500 special edition. I created a new primary partition on my C: drive, inserted the windows 8 install disk, and rebooted my computer from DVD. I select custom install and the dialog box saying "Where do you want to install windows at?" pops up but none of my drives are listed. Please help me determine what is going on. I don't understand why none of my drives are showing up on this menu. Not even the original drive. When I go to load driver and click on the partition I created it tells me "No signed device drivers were found. Make sure the installation media contains the correct drivers, and then click OK." resolved above issue by running setup from the source folder on the install disk instead of booting from DVD. Was able to locate my new partition and start install. It completes the first step of "Copying windows files" just fine but then on the next step "Getting files ready for installation" my computer restarts and attempts to load windows 8 but keeps telling me my pc needs to restart. This keeps going on in an infinite boot loop. Please help, this has been a nightmare!

    Read the article

  • How do you automatically close 3rd party applications when LiberKey is shut down?

    - by NoCatharsis
    Within LiberKey, I have added my own portable applications that are not included within the LiberKey library. When you go into the Properties menu for the app in the LiberKey UI, the Advanced tab has an option for Autoexecute. This dropdown menu seems to have no visible effect, at least on my current installation. I found that I could right click within the primary GUI and select "Add software group", add all 3rd party applications, then go to the Advanced tab within THAT Properties screen and select Autoexecute - "Always on startup". This solved the problem for starting the apps when LiberKey starts. However, now I'm having the same issue when closing out LiberKey. I have created a new 3rd party app that calls the same .exe, but sends the Parameter "/close". I then went to the Advanced tab and selected Autoexecute - "Always on shutdown". Seems pretty logical right? But the apps will not close on LiberKey shutdown. I cannot handle the app close-outs in the same way with a software group, as I did with the startup issue because the Autoexecute drop-down does not have an "Always on shutdown" option. Unfortunately, many of the Q&A forums on liberkey.com are in French and I took Spanish in high school. Otherwise I've not been able to find a workable answer. Any suggestions?

    Read the article

  • One server running Django (with Nginx and Apache) and Wordpress Blog

    - by JCWong
    I have nginx listening to port 80 for my primary site foo.com. It proxys to port 8080 which is where the Django app lives server { listen 80; server_name www.foo.com foo.com; access_log /home/jeffrey/www/ddt/logs/nginx_access.log; error_log /home/jeffrey/www/ddt/logs/nginx_error.log; location / { proxy_pass http://127.0.0.1:8080; include /etc/nginx/proxy.conf; } location /media/ { root /home/jeffrey/www/ddt/; } location /static/ { root /home/jeffrey/www/ddt/; } location /public/ { root /home/jeffrey/www/ddt/; } } I'd like to have a wordpress blog run on the same server. Apache is listening to port 8080 with this http.conf file NameVirtualHost *:8080 WSGIScriptAlias / /home/jeffrey/www/ddt/apache/ddt.wsgi WSGIPythonPath /home/jeffrey/www/ddt <Directory /home/jeffrey/www/ddt/apache/> <Files ddt.wsgi> Order deny,allow Allow from all </Files> </Directory> I added my Wordpress site using a virtualhost <VirtualHost *:8080> ServerName www.bar.com ServerAlias bar.com DocumentRoot /home/jeffrey/www/jeffrey_wp </VirtualHost> When I go to bar.com I still see my django app. Is it possible for these two sites to run on the same server?

    Read the article

  • Bootable GRUB partition

    - by MA1
    I have a customized live fedora 12 USB which is working fine. What i want to do is to make a partition of my hard disk bootable so that my customized fedora can be run from hard disk. To accomplish this i did the following steps: Created a primary partition(/dev/sda2) and format it as ext3 and set it as active. Copy all the files in the live usb to /dev/sda2. Following are the live usb contents(all directories): a. boot b. EFI c. LiveOS d. syslinux Then i installed the GRUB in boot/grub Created the grub.conf in boot/grub Following are the contents of each directory in the USB: syslinux/ boot.cat isolinux.bin splash.jpg vesamenu.c32 initrd0.img ldlinux.sys syslinux.cfg vmlinuz0 LiveOS/ livecd-iso-to-disk osmin.img squashfs.img EFI/ boot/ boot.conf grub.conf boot.efi bootia32.conf bootia32.efi splash.jpg splash.xpm.gz vesamenu.c32 initrd0.img isolinux.bin isolinux.cfg vmlinuz0 boot/grub/ core GRUB files grub.conf olpc.fth Following are contents of grub.conf default=0 splashimage=/EFI/boot/splash.xpm.gz timeout 2 hiddenmenu title funLinux kernel /EFI/boot/vmlinuz0 root=live:LABEL=myFun rootfstype=auto ro liveimg quiet ssb.blacklist=1 selinux=0 vga=normal nomodeset rhgb initrd /EFI/boot/initrd0.img Now when i try to boot from the hard disk it shows the grub menu and fedora starting to load but during loading it said No root device found Boot has failed, sleeping forever So, where is the problem? what i am doing wrong?

    Read the article

  • Replicated MongoDB server slower than simple shards

    - by displayName
    I tried to compare the performance of a sharded configuration against a sharded and replicated configuration. The sharded configuration consists of 8 shards each running on three different machines thereby constituting a total of 24 shards. All 8 of these shards run in the same partition on each machine. The sharded and replicated version is 8 shards again just like plain sharding, and all 8 mongods run on the same partition in each machine. But apart from this, each of these three machine now run additional 16 threads on another partition which serve as the secondary for the 8 mongods running on other machines. This is the way I prepared a sharded and replicated configuration with data chunks having replication factor of 3. Important point to note is that once the data has been loaded, it is not modified. So after primary and secondaries have synchronized then it doesn't matter which one i read from. To run the queries, I use an entirely different machine (let's call it config) which runs mongos and this machine's only purpose is to receive queries and run them on the cluster. Contrary to my expectations, plain sharding of 8 threads on each machine (total = 3 * 8 = 24) is performing better for queries than the sharded + replicated configuration. I have a script written to perform the query. So in order to time the scripts, I use time ./testScript and see the result. I tried changing the reading preference for replicated cluster by logging to mongo of config and run db.getMongo().setReadPref('secondary') and then exit the shell and run the queries like time ./testScript. The questions are: Where am i going wrong in the replication? Why is it slower than its plain sharding version? Does the db.getMongo().ReadPref('secondary') persist when i leave the shell and try to perform the query? All the four machines are running Linux and i have already increased the ulimit -n to 2048 from initial value of 1024 to allow more connections. The collections are properly distributed and all the mongods have equal number of chunks. Goes without saying that indices in both configurations are the same.

    Read the article