Search Results

Search found 4020 results on 161 pages for 'win coder'.

Page 17/161 | < Previous Page | 13 14 15 16 17 18 19 20 21 22 23 24  | Next Page >

  • How add imagelist in Infragistics.Win.UltraWinGrid ?

    - by Nakul Chaudhary
    In past, I am using Listview and using below code can show a particular image for particular memId. But now I need to replace listview with Infragistics.Win.UltraWinGrid problem arise how i show image for ultragrid. For Each LItem As ListViewItem In Me.dvParticipants.Items If CInt(LItem.SubItems(2).Text) = memid Then LItem.ImageIndex = imageindex End If Next Please suggest.

    Read the article

  • Win forms, log all clicks?

    - by chillitom
    Hi All, Is there a way to log all of the clicks in a Win Forms application? I'd like to intercept clicks and record the action and the name of the control that caused it. Is this possible? Thanks in advance.

    Read the article

  • how to get all controls of win form?

    - by Shailesh
    i have a win form named A , A contains lots of different controls ,first contains a main groubbox and this groupbox countains lots of table and others group boxes. i want to find a control which has tab index 9(example) in form A but i dont know which groubox contains this control. how i found this control. regards Shailesh

    Read the article

  • Porting a win32 application to Win CE

    - by ame
    I have a win32 GUI (MFC) application which I need to port to a WIN CE environment. I keep encountering undefined identifiers. What is the best way to deal with this- is there some site where i can get a mapping of some kind between win32 supported features and corresponding wince features (even if they are not supported, the information that they are not is valuable)

    Read the article

  • Mercurial win instal: no ini files

    - by Marwan
    I installed mercurial 1.5.1 on win xp but the files listed in hg help config, were not created. Namely: %USERPROFILE%.hgrc (is that a valid windows file name?) %USERPROFILE%\Mercurial.ini \Mercurial\Mercurial.ini C:\Mercurial\Mercurial.ini (no such directory altogether) %HOME%.hgrc (what is this directory) %HOME%\Mercurial.ini HKEY_LOCAL_MACHINE\SOFTWARE\Mercurial (no registry created) .hg\hgrc (i had to create this file manually to solve my problem)

    Read the article

  • Instant win contest script

    - by zac
    Has anyone seen a good "quick" solution to duct tape together an instant win contest? I need to find a solution where a winner a day gets randomly selected after signing up for email. My company just told me about this and as usual there is really no budget.. no time to accomplish this. Thanks for any ideas.

    Read the article

  • how to use CDialog in win 32 application?

    - by Rakesh
    I did the following steps to use the CDialog in win 32application; 1.Changed the use of MFC to "use mfc shared DLL". 2.Added a dialog resource and added a class for the dialog. 3.Included the dialog class in my main. 4.Tried to call do modal. when i try to call do modal...i am getting an debug assertion failed.. can anybody help me out of this?

    Read the article

  • TCP stops sending weirdly.

    - by Utoah
    In case to find out the cause of TCP retransmits on my Linux (RHEL, kernel 2.6.18) servers connecting to the same switch. I had a client-server pair send "Hello" to each other every 200us and captured the packets with tcpdump on the client machine. The command I used to mimic client and server are: while [ 0 ]; do echo "Hello"; usleep 200; done | nc server 18510 while [ 0 ]; do echo "Hello"; usleep 200; done | nc -l 18510 When the server machine was busy serving some other requests, the client suffered from abrupt retransmits occasionally. But the output of tcpdump seemed irrational. 16:04:58.898970 IP server.18510 > client.34533: P 4531:4537(6) ack 3204 win 123 <nop,nop,timestamp 1923778643 3452833828> 16:04:58.901797 IP client.34533 > server.18510: P 3204:3210(6) ack 4537 win 33 <nop,nop,timestamp 3452833831 1923778643> 16:04:58.901855 IP server.18510 > client.34533: P 4537:4549(12) ack 3210 win 123 <nop,nop,timestamp 1923778646 3452833831> 16:04:58.903871 IP client.34533 > server.18510: P 3210:3216(6) ack 4549 win 33 <nop,nop,timestamp 3452833833 1923778646> 16:04:58.903950 IP server.18510 > client.34533: P 4549:4555(6) ack 3216 win 123 <nop,nop,timestamp 1923778648 3452833833> 16:04:58.905796 IP client.34533 > server.18510: P 3216:3222(6) ack 4555 win 33 <nop,nop,timestamp 3452833835 1923778648> 16:04:58.905860 IP server.18510 > client.34533: P 4555:4561(6) ack 3222 win 123 <nop,nop,timestamp 1923778650 3452833835> 16:04:58.908903 IP client.34533 > server.18510: P 3222:3228(6) ack 4561 win 33 <nop,nop,timestamp 3452833838 1923778650> 16:04:58.908966 IP server.18510 > client.34533: P 4561:4567(6) ack 3228 win 123 <nop,nop,timestamp 1923778653 3452833838> 16:04:58.911855 IP client.34533 > server.18510: P 3228:3234(6) ack 4567 win 33 <nop,nop,timestamp 3452833841 1923778653> 16:04:59.112573 IP client.34533 > server.18510: P 3228:3234(6) ack 4567 win 33 <nop,nop,timestamp 3452834042 1923778653> 16:04:59.112648 IP server.18510 > client.34533: P 4567:5161(594) ack 3234 win 123 <nop,nop,timestamp 1923778857 3452834042> 16:04:59.112659 IP client.34533 > server.18510: P 3234:3672(438) ack 5161 win 35 <nop,nop,timestamp 3452834042 1923778857> 16:04:59.114427 IP server.18510 > client.34533: P 5161:5167(6) ack 3672 win 126 <nop,nop,timestamp 1923778858 3452834042> 16:04:59.114439 IP client.34533 > server.18510: P 3672:3678(6) ack 5167 win 35 <nop,nop,timestamp 3452834044 1923778858> 16:04:59.116435 IP server.18510 > client.34533: P 5167:5173(6) ack 3678 win 126 <nop,nop,timestamp 1923778860 3452834044> 16:04:59.116444 IP client.34533 > server.18510: P 3678:3684(6) ack 5173 win 35 <nop,nop,timestamp 3452834046 1923778860> Packet 3228:3234(6) from client was retransmitted due to ack timeout. What I could not understand was that the client machine did not send out any packets after the first 3228:3234(6) packets was sent. The server machine had advertised a window (scaled) large enough. The data transfer up to the retransmit was fine which meant no slow start should be in action. What can cause the client machine to stop sending until the packet timed out? BTW, I am unable to run tcpdump on the server machine.

    Read the article

  • Win CE 6.0 client using WCF Services

    - by Sean
    We have a Win CE 6.0 device that is required to consume services that will be provided using WCF. We are attempting to reduce bandwidth usage as much as possible and with a simple test we have found that using UDP instead of HTTP saved significant data usage. I understand there are limitations regarding WCF on .NET Compact Framework 3.5 devices and was curious what people thought would be the appropriate way forward. Would it make sense to develop a custom UDP binding, and would that work for both sides? Any feedback would be appreciated. Thanks.

    Read the article

  • Disabling Alt-F4 on a Win Forms NotifyIcon

    - by Jippers
    I am using a NotifyIcon from Win Forms to make a systray icon for my C# application. I have a bug where if the user right clicks the icon for the context menu, they can press Alt-F4 and the icon will disappear from the tray, but the Main WPF application is still running. This is especially a problem when they have "minimized to systray" and the only control of the application is now gone. Anyone know how to handle this specificially on the systray? I've looked at the NotifyIcon documentation and there isn't anything relating to keypress events.

    Read the article

  • Unable to set enviornment variable in platform builder win CE 6.0

    - by mukesh
    Actually while building the win ce project getting the two errors -: Error 1 BUILD: [00:0000000015:ERRORE] C:\WINCE600\PLATFORM\ICOP_Vortex86_60CS\SRC\OAL\OALLIB\obj\x86\debug_objects.mac: create file failed. 2 Error 3 BLDDEMO: There were errors building mytest I think it's comes, due to unset of environmnet variable. facing problem to set environment variable IMGRAM128 in the project proerties, giving the error :- "The variable IMGRAM128 is associated with the 128 RAM catalog item.Would you like to set this variable by adding catalog item in OS design? The varible will not be added to the environmmet tab.............."

    Read the article

  • Trying to compile VS2008 project on Win 64 bit which is custom Powershell PSSnapin

    - by Boris Kleynbok
    Library Project compiles fine for ANY CPU in VS2008 running on Win 7 64 -bit. Now in the post build following command fails when attemptiong to register library dll: PS C:\Windows\Microsoft.NET\Framework64\v2.0.50727 .\installutil C:\path\Project.dll Exception occurred while initializing the installation: System.BadImageFormatException: Could not load file or assembly 'file:///C:\path\Project.dll' or one of its dependencies. An attempt was made to load a program with an incorrect format.. Do I need to compile the project as x64 I was under impression that AnyCPU will take care of it. Alo my library does have dependencies. Do they also need to be compiled as x64 bit? Any help is appreciated.

    Read the article

  • using Mutex causing application to hang on Win XP X64

    - by Mohsan
    hi. I used the following code to verify the single instance of application. On Win XP X86 it is working fine, but on X64 after 3 to 4 minutes System generates StackOverflowException and causes the application to hang. after removing this check application is working fine.. Please tell me what should be the reason. code is static void Main() { bool instanceCountOne = false; using (Mutex mtex = new Mutex(true, "AppName", out instanceCountOne)) { if (instanceCountOne) { #if (DEBUG) RunInDebugMode(); #else RunInReleaseMode(); #endif mtex.ReleaseMutex(); } else { MessageBox.Show( "An application instance is already running", "App Name", MessageBoxButtons.OK, MessageBoxIcon.Information); } } } it crashes when single instance of application is running.

    Read the article

  • MS Detours Library, detouring non win api function

    - by flavour404
    Hi, I want to use the windows detours library to detour a non win api function. The function is part of the Qt library (QtGui4.dll). I am wondering how I would set up the function signature for : void QPainter::drawText ( const QPointF & position, const QString & text ) I had a go with this and it received my usual share of errors, a little explanation of requirements would be interesting as well: void (QPainter * real_drawText)(const QPointF & position, const QString & text) = drawText This is what they look like for TextOut, under the windows API: BOOL (WINAPI * Real_TextOut)(HDC a0, int a1, int a2, LPCWSTR a3, int a4) = TextOutW; BOOL WINAPI Mine_TextOut(HDC hdc,int X,int Y,LPCWSTR text,int textLen) { BOOL rv = Real_TextOut(hdc, X, Y, text, textLen); HWND hWindow = WindowFromDC(hdc); SendTextMessage(hWindow, text); return rv; } Thanks.

    Read the article

  • Win CE 6.0 client using WCF Services - Reduce Bandwidth

    - by Sean
    We have a Win CE 6.0 device that is required to consume services that will be provided using WCF. We are attempting to reduce bandwidth usage as much as possible and with a simple test we have found that using UDP instead of HTTP saved significant data usage. I understand there are limitations regarding WCF on .NET Compact Framework 3.5 devices and was curious what people thought would be the appropriate way forward. Would it make sense to develop a custom UDP binding, and would that work for both sides? Any feedback would be appreciated. Thanks.

    Read the article

  • Embed PowerPoint Viewer in C# Win Form

    - by Soppus
    Is it possible to Embed a PowerPoint Viewer into a C# Windows Form? I am currently use the following code: objApp = new PowerPoint.Application(); //objApp.Visible = MsoTriState.msoTrue; objPresSet = objApp.Presentations; objPres = objPresSet.Open(ppsAction.FileInfo.FullName, MsoTriState.msoTrue, MsoTriState.msoTrue, MsoTriState.msoFalse); objSlides = objPres.Slides; //Run the Slide show objSSS = objPres.SlideShowSettings; objSSS.ShowType = Microsoft.Office.Interop.PowerPoint.PpSlideShowType.ppShowTypeSpeaker; objSSS.LoopUntilStopped = MsoTriState.msoTrue; objSSS.Run(); WindowWrapper handleWrapper = new WindowWrapper(objPres.SlideShowWindow.HWND); SetParent(handleWrapper.Handle, this.ApplicationPanel.Handle); this.ApplicationPanel.Visible = true; objPres.SlideShowWindow.Height = ApplicationPanel.Height; objPres.SlideShowWindow.Width = ApplicationPanel.Width; objPres.SlideShowWindow.Top = 0; objPres.SlideShowWindow.Left = 0; It shows the viewer on the form but the placement and sizing is wrong. How would one size and place it correctly. Another option: I have encountered the Aximp.exe application meant to be used for showing ActiveX controls on the Win Forms in C#. How would I use this with the PPT Viewer?

    Read the article

< Previous Page | 13 14 15 16 17 18 19 20 21 22 23 24  | Next Page >