Search Results

Search found 26104 results on 1045 pages for 'command pattern'.

Page 178/1045 | < Previous Page | 174 175 176 177 178 179 180 181 182 183 184 185  | Next Page >

  • How to "grep" out specific line ranges of a file

    - by Mike
    There are often times I'll grep -l whatev file to find what I'm looking for. Say the output is 1234: whatev 1 5555: whatev 2 6643: whatev 3 If I want to then just extract the lines between 1234 and 5555, is there a tool to do that? For static files I have a script that does wc -l of the file and then does the math to split it out with tail & head but that doesn't work out so well with log files that are constantly being written to.

    Read the article

  • how to search for a term only in non test files

    - by dorelal
    I use ack and I like it. However from time to time I need to search for something in my code base and I want to ignore all the files residing in test directory. Basically all the files which have test in their absolute path should be not included in the search. How do I achieve that? I am willing to have a custom bash script. Something like ack_no_test "application" - search for "application" in all files but ignore files residing in test directory

    Read the article

  • How to prevent regex from stopping at the first match of alternatives ?

    - by miket2e
    If I have the string hello world , how can I modify the regex world|wo|w so that it will match all of "world", "wo" and "w" rather than just the single first match of "world" that it comes to ? If this is not possible directly, is there a good workaround ? I'm using C# if it makes a difference: Regex testRegex = new Regex("world|wo|w"); MatchCollection theMatches = testRegex.Matches("hello world"); foreach (Match thisMatch in theMatches) { ... }

    Read the article

  • Generic factory of generic containers

    - by Feuermurmel
    I have a generic abstract class Factory<T> with a method createBoxedInstance() which returns instances of T created by implementations of createInstance() wrapped in the generic container Box<T>. abstract class Factory<T> { abstract T createInstance(); public final Box<T> createBoxedInstance() { return new Box<T>(createInstance()); } public final class Box<T> { public final T content; public Box(T content) { this.content = content; } } } At some points I need a container of type Box<S> where S is an ancestor of T. Is it possible to make createBoxedInstance() itself generic so that it will return instances of Box<S> where S is chosen by the caller? Sadly, defining the function as follows does not work as a type parameter cannot be declared using the super keyword, only used. public final <S super T> Box<S> createBoxedInstance() { return new Box<S>(createInstance()); } The only alternative I see, is to make all places that need an instance of Box<S> accept Box<? extends S> which makes the container's content member assignable to S. Is there some way around this without re-boxing the instances of T into containers of type Box<S>? (I know I could just cast the Box<T> to a Box<S> but I would feel very, very guilty.)

    Read the article

  • How can I detect common substrings in a list of strings

    - by danio
    Given a set of strings, for example: EFgreen EFgrey EntireS1 EntireS2 J27RedP1 J27GreenP1 J27RedP2 J27GreenP2 JournalP1Black JournalP1Blue JournalP1Green JournalP1Red JournalP2Black JournalP2Blue JournalP2Green I want to be able to detect that these are three sets of files: EntireS[1,2] J27[Red,Green]P[1,2] JournalP[1,2][Red,Green,Blue] Are there any known ways of approaching this problem - any published papers I can read on this? The approach I am considering is for each string look at all other strings and find the common characters and where differing characters are, trying to find sets of strings that have the most in common, but I fear that this is not very efficient and may give false positives. Note that this is not the same as 'How do I detect groups of common strings in filenames' because that assumes that a string will always have a series of digits following it. [Edited 15/09/09 to add more sample strings]

    Read the article

  • How to make shell output redirect (>) write while script is still running?

    - by Noio
    I wrote a short script that never terminates. This script continuously generates output that I have to check on every now and then. I'm running it on a lab computer through SSH, and redirecting the output to a file in my public_html folder on that machine. python script.py > ~/public_html/results.txt However, the results don't show up immediately when I refresh the address. The results show up when I terminate the program, but as I said, it doesn't halt by itself. Is that redirect (>) being lazy with with writing? Is there a way to continuously (or with an interval) update the results in the file? Or is it the webserver that doesn't update the file while it is still being written?

    Read the article

  • Can I do filename pattern matching in a bash script?

    - by Bob Bowden
    Can I do filename pattern matching in a bash script? "test" is a directory with the following files ... bob@bob-laptop:~/test$ ls exclude exclude1 exclude2 include1 include2 from the command line, if I want to exclude some of the files, I can do ... bob@bob-laptop:~/test$ echo !(exclude*) include1 include2 but, if I put that command in a script (named exclude) ... bob@bob-laptop:~/test$ cat exclude echo !(exclude*) when I execute it, I get an error ... bob@bob-laptop:~/test$ ./exclude ./exclude: line 1: syntax error near unexpected token (' ./exclude: line 1:echo !(exclude*)' I've tried every (I think) variation of escaping some, all or none of the special characters and I still get an error. What am I missing here? If I can't do this, would someone please be so kind as to explain why?

    Read the article

  • SATA errors reported during boot: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0

    - by digby280
    I have noticed some error during the Linux boot. They seem to continue to occur after the boot adding lines to the log every few seconds. Once booted this normally does not appear to be causing any problems. However, around 1 in 10 boots results in a kernel panic and the computer has on two or three occasions suddenly rebooted after being powered on for a number of hours. I presume the cause of the reboot is a kernel panic as well. I am running Ubuntu 11.10 and I have had Ubuntu installed on the computer for around a year. I have googled around and not found anything useful. I have provided the kernel log lines and the output of smartctl. Can anyone explain exactly what these errors mean, or better still how to resolve them? Apr 2 16:51:27 dell580 kernel: [ 19.831140] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:27 dell580 kernel: [ 19.934194] tg3 0000:03:00.0: eth0: Link is down Apr 2 16:51:28 dell580 kernel: [ 20.929468] tg3 0000:03:00.0: eth0: Link is up at 100 Mbps, full duplex Apr 2 16:51:28 dell580 kernel: [ 20.929471] tg3 0000:03:00.0: eth0: Flow control is on for TX and on for RX Apr 2 16:51:28 dell580 kernel: [ 20.929727] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready Apr 2 16:51:29 dell580 kernel: [ 21.609381] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:29 dell580 kernel: [ 21.616515] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:29 dell580 kernel: [ 21.616519] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:29 dell580 kernel: [ 21.616525] ata2.00: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 21.934036] ata2.01: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 22.408890] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.408907] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.440934] ata2.00: configured for UDMA/100 Apr 2 16:51:29 dell580 kernel: [ 22.449040] ata2.01: configured for UDMA/133 Apr 2 16:51:29 dell580 kernel: [ 22.449818] ata2: EH complete Apr 2 16:51:33 dell580 kernel: [ 26.122664] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:33 dell580 kernel: [ 26.122670] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:33 dell580 kernel: [ 26.122677] ata2.00: hard resetting link Apr 2 16:51:33 dell580 kernel: [ 26.442684] ata2.01: hard resetting link Apr 2 16:51:34 dell580 kernel: [ 26.925545] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.925561] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.961542] ata2.00: configured for UDMA/100 Apr 2 16:51:34 dell580 kernel: [ 26.969616] ata2.01: configured for UDMA/133 Apr 2 16:51:34 dell580 kernel: [ 26.970400] ata2: EH complete Apr 2 16:51:35 dell580 kernel: [ 28.111180] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:35 dell580 kernel: [ 28.111184] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:35 dell580 kernel: [ 28.111191] ata2.00: hard resetting link Apr 2 16:51:35 dell580 kernel: [ 28.429674] ata2.01: hard resetting link Apr 2 16:51:36 dell580 kernel: [ 28.904557] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.904572] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.936609] ata2.00: configured for UDMA/100 Apr 2 16:51:36 dell580 kernel: [ 28.944692] ata2.01: configured for UDMA/133 Apr 2 16:51:36 dell580 kernel: [ 28.945464] ata2: EH complete Apr 2 16:51:38 dell580 kernel: [ 31.581756] eth0: no IPv6 routers present Apr 2 16:51:38 dell580 kernel: [ 32.103066] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:38 dell580 kernel: [ 32.103074] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:38 dell580 kernel: [ 32.103085] ata2.00: hard resetting link Apr 2 16:51:38 dell580 kernel: [ 32.419669] ata2.01: hard resetting link Apr 2 16:51:39 dell580 kernel: [ 32.894518] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.894533] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.926536] ata2.00: configured for UDMA/100 Apr 2 16:51:39 dell580 kernel: [ 32.934715] ata2.01: configured for UDMA/133 Apr 2 16:51:39 dell580 kernel: [ 32.935578] ata2: EH complete Here's the output of smartctl for the drive. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-17-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: S13PJ90QC19706 LU WWN Device Id: 5 0000f0 00b1c7960 Firmware Version: 1AA01113 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Mon Apr 2 17:13:48 2012 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (11772) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 197) minutes. Conveyance self-test routine recommended polling time: ( 21) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 076 076 011 Pre-fail Always - 7940 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 521 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 642 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 482 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 759 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 069 000 Old_age Always - 27 (Min/Max 16/27) 194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/28) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 320028 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 099 099 000 Old_age Always - 1494 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 211 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 211 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 31 63 8f e1 Error: ICRC, ABRT 15 sectors at LBA = 0x018f6331 = 26174257 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 40 62 8f e1 08 00:01:00.460 READ DMA c8 00 20 00 7c 30 e0 08 00:01:00.450 READ DMA c8 00 00 10 49 8f e1 08 00:01:00.440 READ DMA c8 00 e0 20 d0 30 e0 08 00:01:00.420 READ DMA c8 00 00 c0 59 90 e1 08 00:01:00.400 READ DMA Error 210 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 cf e9 cf 66 e0 Error: ICRC, ABRT 207 sectors at LBA = 0x0066cfe9 = 6737897 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 b8 cf 66 e0 08 00:08:29.780 READ DMA c8 00 60 60 c9 18 e0 08 00:08:29.770 READ DMA c8 00 40 20 c9 18 e0 08 00:08:29.770 READ DMA c8 00 20 00 c9 18 e0 08 00:08:29.760 READ DMA c8 00 20 98 cf 66 e0 08 00:08:29.750 READ DMA Error 209 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f d1 74 e0 e0 Error: ICRC, ABRT 47 sectors at LBA = 0x00e074d1 = 14709969 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 00 74 e0 e0 08 00:00:30.940 READ DMA c8 00 20 18 36 de e0 08 00:00:30.930 READ DMA c8 00 08 48 f1 dd e0 08 00:00:30.930 READ DMA c8 00 08 a8 f0 dd e0 08 00:00:30.930 READ DMA c8 00 08 90 f0 dd e0 08 00:00:30.930 READ DMA Error 208 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 21 88 9d e0 Error: ICRC, ABRT 127 sectors at LBA = 0x009d8821 = 10324001 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 00 88 9d e0 08 00:00:27.610 READ DMA c8 00 58 a8 e7 9c e0 08 00:00:27.610 READ DMA c8 00 00 28 e6 9c e0 08 00:00:27.610 READ DMA c8 00 00 e0 e4 9c e0 08 00:00:27.610 READ DMA c8 00 00 90 e0 9c e0 08 00:00:27.600 READ DMA Error 207 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 26 6a 6a c3 e0 Error: ABRT at LBA = 0x00c36a6a = 12806762 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ca 00 00 90 69 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 68 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 50 65 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 d0 64 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 63 c3 e0 08 00:29:39.350 WRITE DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 638 - # 2 Short offline Interrupted (host reset) 90% 638 - # 3 Extended offline Interrupted (host reset) 90% 638 - # 4 Short offline Interrupted (host reset) 90% 638 - # 5 Extended offline Interrupted (host reset) 90% 638 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • stop and split generated sequence at repeats - clojure

    - by fitzsnaggle
    I am trying to make a sequence that will only generate values until it finds the following conditions and return the listed results: case head = 0 - return {:origin [all generated except 0] :pattern 0} 1 - return {:origin nil :pattern [all-generated-values] } repeated-value - {:origin [values-before-repeat] :pattern [values-after-repeat] { ; n = int ; x = int ; hist - all generated values ; Keeps the head below x (defn trim-head [head x] (loop [head head] (if (> head x) (recur (- head x)) head))) ; Generates the next head (defn next-head [head x n] (trim-head (* head n) x)) (defn row [x n] (iterate #(next-head % x n) n)) ; Generates a whole row - ; Rows are a max of x - 1. (take (- x 1) (row 11 3)) Examples of cases to stop before reaching end of row: [9 8 4 5 6 7 4] - '4' is repeated so STOP. Return preceding as origin and rest as pattern. {:origin [9 8] :pattern [4 5 6 7]} [4 5 6 1] - found a '1' so STOP, so return everything as pattern {:origin nil :pattern [4 5 6 1]} [3 0] - found a '0' so STOP {:origin [3] :pattern [0]} :else if the sequences reaches a length of x - 1: {:origin [all values generated] :pattern nil} The Problem I have used partition-by with some success to split the groups at the point where a repeated value is found, but would like to do this lazily. Is there some way I can use take-while, or condp, or the :while clause of the for loop to make a condition that partitions when it finds repeats? Some Attempts (take 2 (partition-by #(= 1 %) (row 11 4))) (for [p (partition-by #(stop-match? %) head) (iterate #(next-head % x n) n) :while (or (not= (last p) (or 1 0 n) (nil? (rest p))] {:origin (first p) :pattern (concat (second p) (last p))})) # Updates What I really want to be able to do is find out if a value has repeated and partition the seq without using the index. Is that possible? Something like this - { (defn row [x n] (loop [hist [n] head (gen-next-head (first hist) x n) steps 1] (if (>= (- x 1) steps) (case head 0 {:origin [hist] :pattern [0]} 1 {:origin nil :pattern (conj hist head)} ; Speculative from here on out (let [p (partition-by #(apply distinct? %) (conj hist head))] (if-not (nil? (next p)) ; One partition if no repeats. {:origin (first p) :pattern (concat (second p) (nth 3 p))} (recur (conj hist head) (gen-next-head head x n) (inc steps))))) {:origin hist :pattern nil}))) }

    Read the article

  • What exactly is a Deamon ? ( how to run a root command from apache binded script that uses www-data user )?

    - by user224235
    I am trying to run this command from WSGI script service httpd restart The problem is this command can only be run by root and apache uses the www-data user. it has been said the solution is to use a Deamon Process i suppose the idea is to send the command to a file that will be executed by a script that is considered "root" user.. its difficult to understand why they would call this a Deamon Process and try to scare me. Perhaps it should have been called : proxy process when i got the idea that this was a proxy process.. i thought about adding a line to /var/spool/cron/root that way the cron would execute the command for me. but of course this means i have to get the system time and then add 1 second to it and then add it to that line so cron would execute the command for me as root but my script demands an output instantly. so i suppose i need to create a DEAMON PROCESS that works like the cron. in other words it is a bash file that will execute the command in a plain file.. but will this DEAMON PROCESS be running a while command 24/7 every second ? would that not waste resources ? it only needs to activate itself to check for a command to execute when there is a command to be executed. i mean in PHP and other programming languages.. running a while statement when there is nothing to be executed could waste resources of the server.. so why should a deamon process constantly be listening for anything. i only want it to listen and execute when it is needed. i do not need a process that is constantly listening.

    Read the article

  • Use command line to add application to gnome classic panel?

    - by dmd
    How can I add an application shortcut to a panel in gnome-classic, using the command line? I used dconf watch / to see what was happening when I did it by hand, but when I try reproducing that myself: dmd@rossum:~ $ dconf write '/org/gnome/gnome-panel/layout/objects/test1234/object-iid' 'PanelInternalFactory::Launcher' error: 0-1:unknown keyword I run into trouble right away. How can I add (e.g.) a terminal launcher icon to a panel using the command line?

    Read the article

  • Is Cygwin or Windows Command Prompt preferable for getting a consistent terminal experience for development?

    - by Paul Hazen
    The question: Which is better, installing cygwin or one of its cousins on all my windows machines to have a consistent terminal experience across all my development machines, or becoming well trained in the skill of mentally switching from linux terminal to windows command prompt? Systems I use: OSX Lion on a Macbook Air Windows 8 on a desktop Windows 7 on the same desktop Fedora 16 on the same desktop What I'm trying to accomplish Configure an entirely consistent (or consistent enough) terminal experience across all my machines. "enough" in this context is clearly subjective. Please be clear in your answer why the configuration you suggest is consistent enough. One more thing to keep in mind: While I do write a lot of code intended to run on Windows (actually code that runs on Windows Phone which necessitates a windows machine), I also write a lot of Java code, and prefer to do so in vim. I test a local repo in Java on my windows machine, and push to another test machine running ubuntu later in the development stage. When I push to the ubuntu machine, I'm exclusively in terminal, since I'm accessing it via SSH. Summary, with more accurate question: Is there a good way to accomplish what I'm trying to do, or is it better to get accustomed to remembering different commands based on the system I'm on? Which (if either) is considered "best practice" by the development community? Alternatively, for a consistent development experience, would it be better to write all my code SSHed into another machine, and move things to windows for compile / build only when I needed to? That seems like too much work... but could be a solution. Update: While there are insightful responses below, I have yet to hear an answer that talks about why any given solution is superior. Cygwin/GnuWin32 is certainly a way to accomplish a similar experience on all platforms, but since I'm just learning all things command line, I don't want to set myself up to do a lot of relearning/unlearning in the future. Cygwin/GnuWin32 has its peculiarities I would imagine, and being aware of how that set up works on Windows is a learning curve. Additionally, using Cygwin/GnuWin32 robs me of learning the benefits of PowerShell. As a newcomer to working in a command line, which path should I choose to minimize having to relearn/unlearn things in the future? or as my first paragraph poses: [is it better to use Cygwin] ...or [become] well trained in the skill of mentally switching from linux terminal to windows command prompt?

    Read the article

  • How to get the users set of date format pattern strings? (3 replies)

    I would like to get the current user's set of date format pattern strings as listed in the Control Panel regional settings applet. For my UK English system I see the following patterns listed: Short Date: dd/MM/yyyy dd/MM/yy d/M/yy d.M.yy yyyy MM dd Long Date: dd MMMM yyyy d MMMM yyyy If I use GetDateTimeFormats (d and D) the results match the expected patterns above, but of course they're the for...

    Read the article

  • How to get the users set of date format pattern strings? (3 replies)

    I would like to get the current user's set of date format pattern strings as listed in the Control Panel regional settings applet. For my UK English system I see the following patterns listed: Short Date: dd/MM/yyyy dd/MM/yy d/M/yy d.M.yy yyyy MM dd Long Date: dd MMMM yyyy d MMMM yyyy If I use GetDateTimeFormats (d and D) the results match the expected patterns above, but of course they're the for...

    Read the article

  • Is this a pattern? Should it be?

    - by Arkadiy
    The following is more of a statement than a question - it describes something that may be a pattern. The question is: is this a known pattern? Or, if it's not, should it be? I've had a situation where I had to iterate over two dissimilar multi-layer data structures and copy information from one to the other. Depending on particular use case, I had around eight different kinds of layers, combined in about eight different combinations: A-B-C B-C A-C D-E A-D-E and so on After a few unsuccessful attempts to factor out the repetition of per-layer iteration code, I realized that the key difficulty in this refactoring was the fact that the bottom level needed access to data gathered at higher levels. To explicitly accommodate this requirement, I introduced IterationContext class with a number of get() and set() methods for accumulating the necessary information. In the end, I had the following class structure: class Iterator { virtual void iterateOver(const Structure &dataStructure1, IterationContext &ctx) const = 0; }; class RecursingIterator : public Iterator { RecursingIterator(const Iterator &below); }; class IterateOverA : public RecursingIterator { virtual void iterateOver(const Structure &dataStructure1, IterationContext &ctx) const { // Iterate over members in dataStructure1 // locate corresponding item in dataStructure2 (passed via context) // and set it in the context // invoke the sub-iterator }; class IterateOverB : public RecursingIterator { virtual void iterateOver(const Structure &dataStructure1, IterationContext &ctx) const { // iterate over members dataStructure2 (form context) // set dataStructure2's item in the context // locate corresponding item in dataStructure2 (passed via context) // invoke the sub-iterator }; void main() { class FinalCopy : public Iterator { virtual void iterateOver(const Structure &dataStructure1, IterationContext &ctx) const { // copy data from structure 1 to structure 2 in the context, // using some data from higher levels as needed } } IterationContext ctx(dateStructure2); IterateOverA(IterateOverB(FinalCopy())).iterate(dataStructure1, ctx); } It so happens that dataStructure1 is a uniform data structure, similar to XML DOM in that respect, while dataStructure2 is a legacy data structure made of various structs and arrays. This allows me to pass dataStructure1 outside of the context for convenience. In general, either side of the iteration or both sides may be passed via context, as convenient. The key situation points are: complicated code that needs to be invoked in "layers", with multiple combinations of layer types possible at the bottom layer, the information from top layers needs to be visible. The key implementation points are: use of context class to access the data from all levels of iteration complicated iteration code encapsulated in implementation of pure virtual function two interfaces - one aware of underlying iterator, one not aware of it. use of const & to simplify the usage syntax.

    Read the article

  • What type of command can I use for shortcut assignment?

    - by navie
    We all know that Ubuntu 12 has a shortcut mapper under "Keyboard" utility. I wonder when it asks for "command" in the new shortcut dialog, what type of command can I use? I used to think that commands in terminal can also be used here, but it seems xdotool is not like that. btw, if xdotool is not the right solution, how to map a key combination to a another key? for e.g.: alt+j to Down arrow key Thank you

    Read the article

  • Is this a valid implementation of the repository pattern?

    - by user1578653
    I've been reading up about the repository pattern, with a view to implementing it in my own application. Almost all examples I've found on the internet use some kind of existing framework rather than showing how to implement it 'from scratch'. Here's my first thoughts of how I might implement it - I was wondering if anyone could advise me on whether this is correct? I have two tables, named CONTAINERS and BITS. Each CONTAINER can contain any number of BITs. I represent them as two classes: class Container{ private $bits; private $id; //...and a property for each column in the table... public function __construct(){ $this->bits = array(); } public function addBit($bit){ $this->bits[] = $bit; } //...getters and setters... } class Bit{ //some properties, methods etc... } Each class will have a property for each column in its respective table. I then have a couple of 'repositories' which handle things to do with saving/retrieving these objects from the database: //repository to control saving/retrieving Containers from the database class ContainerRepository{ //inject the bit repository for use later public function __construct($bitRepo){ $this->bitRepo = $bitRepo; } public function getById($id){ //talk directly to Oracle here to all column data into the object //get all the bits in the container $bits = $this->bitRepo->getByContainerId($id); foreach($bits as $bit){ $container->addBit($bit); } //return an instance of Container } public function persist($container){ //talk directly to Oracle here to save it to the database //if its ID is NULL, create a new container in database, otherwise update the existing one //use BitRepository to save each of the Bits inside the Container $bitRepo = $this->bitRepo; foreach($container->bits as $bit){ $bitRepo->persist($bit); } } } //repository to control saving/retrieving Bits from the database class BitRepository{ public function getById($id){} public function getByContainerId($containerId){} public function persist($bit){} } Therefore, the code I would use to get an instance of Container from the database would be: $bitRepo = new BitRepository(); $containerRepo = new ContainerRepository($bitRepo); $container = $containerRepo->getById($id); Or to create a new one and save to the database: $bitRepo = new BitRepository(); $containerRepo = new ContainerRepository($bitRepo); $container = new Container(); $container->setSomeProperty(1); $bit = new Bit(); $container->addBit($bit); $containerRepo->persist($container); Can someone advise me as to whether I have implemented this pattern correctly? Thanks!

    Read the article

  • What's the difference between these design pattern books? [on hold]

    - by BSara
    I'm currently looking for a good reference/guide for design patterns and in my search I've found the following three books highly recommended: Design Patterns: Elements of Reusable Object-Oriented Software Pattern Hatching: Design Patterns Applied Design Patterns Explained: A New Perspective on Object-Oriented Design I can't decide which book (if any) to purchase. So, my question is this: What are the fundamental differences between these books?

    Read the article

  • Having trouble running code analysis from command prompt with msbuild

    - by devlife
    I'm using VS2010 RC while targeting .NET 3.5. I can run code analysis via Visual Studio without a problem. However, when I try to run code analysis on our CI server it isn't getting executed. When I attempt to build using msbuild 4.0 I get the following exception: C:\Program Files (x86)\MSBuild\Microsoft\VisualStudio\v10.0\CodeAnalysis\Microsoft.CodeAnalysis.targets(129,9): error MSB4018: The "CodeAnalysis" task failed unexpectedly. C:\Program Files (x86)\MSBuild\Microsoft\VisualStudio\v10.0\CodeAnalysis\Microsoft.CodeAnalysis.targets(129,9): error MSB4018: System.TypeLoadException: Could not load type 'System.Runtime.Versioning.TargetFrameworkAttribute' from assembly 'mscorlib, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089 Like I said, it works fine when I run it through VS.

    Read the article

  • Josh Smith's MVVM Demo App: Add commands to MainWindowViewModel's command list

    - by MAD9
    I have a question concerning Josh Smith's famous demo app on MVVM. I try building a "real" application around it to learn WPF. He creates this CommandsList in the MainWindowViewModel containing 2 Commands (create new and view all customers). This list is readonly (why? any particular reason?). I thougt it would be nice to add and remove some commands, depending on the workspace that is currently selected. Like edit or delete a customer when it has the focus and so on. How would I accomplish this?! Can I just make it a normal list and add commands? Or bind the Commands-View to a commands list of the selected workspace instead of the MainWindow? How? Any other ways? Please share your ideas! Thank you very much!

    Read the article

  • C# Dynamically created LinkButton Command Event Handler

    - by spdevsolutions
    So I have a weird situation here... I have an System.Web.UI.WebControls.WebParts.EditorPart class. It renders a "Search" button, when you click this button, it's clickHandler method does a DB search, and dynamically creates a LinkButton for each row it returns, sets the CommandName and CommandArgument properties and adds a CommandEventHandler method, then adds the LinkButton control to the page. The problem is, when you click a LinkButton, its CommandEventHandler method is never called, it looks like the page just posts back to where it was before the ORIGINAL "Search" button was pressed. I have seen postings saying that you need to add the event handlers in OnLoad() or some other early method, but my LinkButtons haven't even been created until the user tells us what to search for and hits the "Search" button... Any ideas on how to deal with this? Thanks!

    Read the article

< Previous Page | 174 175 176 177 178 179 180 181 182 183 184 185  | Next Page >