Search Results

Search found 14653 results on 587 pages for 'disk cache'.

Page 193/587 | < Previous Page | 189 190 191 192 193 194 195 196 197 198 199 200  | Next Page >

  • What to have in mind when building a AJAX-based webapp

    - by Industrial
    Hi everyone, We're in the first steps of what will be a AJAX-based webapp where information and generated HTML will be sent backwards and forwards with the help of JSON/POST techniques. We're able to get the data out quickly without putting to much load on the database with the help of a cache-layer that features memcached as well as disc-based cache. Besides that - what's essential to have in mind when designing AJAX heavy webapps? Thanks a lot,

    Read the article

  • Add console.profile statements to JavaScript/jQuery code on the fly.

    - by novogeek
    Hi folks, We have a thick client app using jQuery heavily and want to profile the performance of the code using firebug's console.profile API. The problem is, I don't want to change the code to write the profile statements. Take this example: var search=function(){ this.init=function(){ console.log('init'); } this.ajax=function(){ console.log('ajax'); //make ajax call using $.ajax and do some DOM manipulations here.. } this.cache=function(){ console.log('cache'); } } var instance=new search(); instance.ajax(); I want to profile my instance.ajax method, but I dont want to add profile statements in the code, as that makes it difficult to maintain the code. I'm trying to override the methods using closures, like this: http://www.novogeek.com/post/2010/02/27/Overriding-jQueryJavaScript-functions-using-closures.aspx but am not very sure how I can achieve. Any pointers on this? I think this would help many big projects to profile the code easily without a big change in code. Here is the idea. Just run the below code in firebug console, to know what I'm trying to achieve. var search=function(){ this.init=function(){ console.log('init'); } this.ajax=function(){ console.log('ajax'); //make ajax call using $.ajax and do some DOM manipulations here.. } this.cache=function(){ console.log('cache'); } } var instance=new search(); $.each(instance, function(functionName, functionBody){ (function(){ var dup=functionBody functionBody=function(){ console.log('modifying the old function: ',functionName); console.profile(functionName); dup.apply(this,arguments); console.profileEnd(functionName); } })(); console.log(functionName, '::', functionBody()); }); Now what I need is, if i say instance.ajax(), I want the new ajax() method to be called, along with the console.profile statements. Hope I'm clear with the requirement. Please improvise the above code. Regards, Krishna, http://www.novogeek.com

    Read the article

  • log in and send sms with java

    - by noobed
    I'm trying to log into a site and afterwards to send a SMS (you can do that for free by the site - it's nothing more than just enter some text into some fields and 'submit'). I've used wireshark to track some of the post/get requests that my machine has been exchanging with the server - when using the browser. I'd like to paste some of my Java code: URL url; String urlP = "maccount=myRawUserName7&" + "mpassword=myRawPassword&" + "redirect_http=http&" + "submit=........"; String urlParameters = URLEncoder.encode(urlP, "CP1251"); HttpURLConnection connection = null; // Create connection url = new URL("http://www.mtel.bg/1/mm/smscenter/mc/sendsms/ma/index/mo/1"); connection = (HttpURLConnection) url.openConnection(); connection.setRequestMethod("POST"); //I'm not really sure if these RequestProperties are necessary //so I'll leave them as a comment // connection.setRequestProperty("Content-Type", // "application/x-www-form-urlencoded"); // connection.setRequestProperty("Accept-Charset", "CP1251"); // connection.setRequestProperty("Content-Length", // "" + Integer.toString(urlParameters.getBytes().length)); // connection.setRequestProperty("Content-Language", "en-US"); connection.setUseCaches(false); connection.setDoInput(true); connection.setDoOutput(true); // Send request DataOutputStream wr = new DataOutputStream( connection.getOutputStream()); wr.writeBytes(urlParameters); wr.flush(); wr.close(); String headerName[] = new String[10]; int count = 0; for (int i = 1; (headerName[count] = connection.getHeaderFieldKey(i)) != null; i++) { if (headerName[count].equals("Set-Cookie")) { headerName[count++] = connection.getHeaderField(i); } } //I'm not sure if I have to close the connection here or not if (connection != null) { connection.disconnect(); } //the code above should be the login part //----------------------------------------- //this is copy-pasted from wireshark's info. String smsParam="from=men&" + "sender=0&" + "msisdn=359886737498&" + "tophone=0&" + "smstext=tova+e+proba%21+1.&" + "id=&" + "sendaction=&" + "direction=&" + "msgLen=84"; url = new URL("http://www.mtel.bg/moyat-profil-sms-tsentar_3004/" + "mm/smscenter/mc/sendsms/ma/index"); connection = (HttpURLConnection) url.openConnection(); connection.setRequestMethod("POST"); connection.setRequestProperty("Cookie", headerName[0]); connection.setRequestProperty("Cookie", headerName[1]); //conn urlParameters = URLEncoder.encode(urlP, "CP1251"); connection.setUseCaches(false); connection.setDoInput(true); connection.setDoOutput(true); wr = new DataOutputStream( connection.getOutputStream()); wr.writeBytes(urlParameters); wr.flush(); wr.close(); //I'm not rly sure what exactly to do with this response. // Get Response InputStream is = connection.getInputStream(); BufferedReader rd = new BufferedReader(new InputStreamReader(is, "CP1251")); String line; StringBuffer response = new StringBuffer(); while ((line = rd.readLine()) != null) { response.append(line); response.append('\r'); } rd.close(); System.out.println(response.toString()); if (connection != null) { connection.disconnect(); } so that's my code so far. When I execute it ... I don't receive any text on my phone - so it clearly doesn't work as supposed to. I would appreciate any guidance or remarks. Is my cookie handling wrong? Is my login method wrong? Do I pass the right URLs. Do I encode and send the parameter string correctly? Is there any addition valuable data from these POSTs I should take? P.S. just in any case let me tell you that the username and password is not real. For security reasons I don't want to give valid ones. (I think this is appropriate approach) Here are the POST requests: POST /1/mm/auth/mc/auth/ma/index/mo/1 HTTP/1.1 Host: www.mtel.bg User-Agent: Mozilla/5.0 (Windows NT 6.1; WOW64; rv:15.0) Gecko/20100101 Firefox/15.0.1 Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8 Accept-Language: en-us,en;q=0.5 Accept-Encoding: gzip, deflate Connection: keep-alive Referer: http://www.mtel.bg/1/mm/smscenter/mc/sendsms/ma/index/mo/1 Cookie: __utma=209782857.541729286.1349267381.1349270269.1349274374.3; __utmc=209782857; __utmz=209782857.1349267381.1.1.utmcsr=(direct)|utmccn=(direct)|utmcmd=(none); __atuvc=28%7C40; PHPSESSID=q0mage2usmv34slcv3dmd6t057; __utmb=209782857.3.10.1349274374 Content-Type: multipart/form-data; boundary=---------------------------151901450223722 Content-Length: 475 -----------------------------151901450223722 Content-Disposition: form-data; name="maccount" myRawUserName -----------------------------151901450223722 Content-Disposition: form-data; name="mpassword" myRawPassword -----------------------------151901450223722 Content-Disposition: form-data; name="redirect_https" http -----------------------------151901450223722 Content-Disposition: form-data; name="submit" ........ -----------------------------151901450223722-- HTTP/1.1 302 Found Server: nginx Date: Wed, 03 Oct 2012 14:26:40 GMT Content-Type: text/html; charset=Utf-8 Connection: close Expires: Thu, 19 Nov 1981 08:52:00 GMT Cache-Control: no-store, no-cache, must-revalidate, post-check=0, pre-check=0 Pragma: no-cache Location: /moyat-profil-sms-tsentar_3004/mm/smscenter/mc/sendsms/ma/index Content-Length: 0 The above text is vied with wireshark's follow tcp stream when pressing the log in button. POST /moyat-profil-sms-tsentar_3004/mm/smscenter/mc/sendsms/ma/index HTTP/1.1 *same as the above ones* Referer: http://www.mtel.bg/moyat-profil-sms-tsentar_3004/mm/smscenter/mc/sendsms/ma/index Cookie: __utma=209782857.541729286.1349267381.1349270269.1349274374.3; __utmc=209782857; __utmz=209782857.1349267381.1.1.utmcsr=(direct)|utmccn=(direct)|utmcmd=(none); __atuvc=29%7C40; PHPSESSID=q0mage2usmv34slcv3dmd6t057; __utmb=209782857.4.10.1349274374 Content-Type: application/x-www-form-urlencoded Content-Length: 147 from=men&sender=0&msisdn=35988888888&tophone=0&smstext=this+is+some+FREE+SMS+text%21+100+char+per+sms+only%21&id=&sendaction=&direction=&msgLen=50 HTTP/1.1 302 Found Server: nginx Date: Wed, 03 Oct 2012 14:31:38 GMT Content-Type: text/html; charset=Utf-8 Connection: close Expires: Thu, 19 Nov 1981 08:52:00 GMT Cache-Control: no-store, no-cache, must-revalidate, post-check=0, pre-check=0 Pragma: no-cache Location: /moyat-profil-sms-tsentar_3004/mm/smscenter/mc/sendsms/ma/success/s/1 Content-Length: 0 The above text is when you press the send button.

    Read the article

  • Caching images with asp/http

    - by Dmitry Makovetskiyd
    I want to cache all the images on my site, so I used this code: <%Response.AddHeader "Expires","Tue, 2 October 2013 00:00:00 GMT"%> The problem is that google says the images are not cached, whenever I go to this site: https://developers.google.com/speed/pagespeed Also in chrome, I can see that it gives a Get response for all the images. Why is that and how can I cache the images for the next year.

    Read the article

  • Controlling youtube traffic path ingoing to multihoming network

    - by Hamdy Ali
    Scenario: I've network multihoming (dual ISP) setup. each ISP bandwidth 500Mbps Currently ISP-A link bandwidth almost fully utilized then the second ISP-B link From our investigation, it is because youtube server cache response to link ISP-A. Some time the utilization of link ISP B increased because at that time youtube server cached is response to ISP B. My question how/Why did this happen? how do I force youtube cache server using ISP link B?

    Read the article

  • MySQL: Query Cacheing (How do I use memcache?)

    - by Rachel
    I have an query like: SELECT id as OfferId FROM offers WHERE concat(partycode, connectioncode) = ? AND CURDATE() BETWEEN offer_start_date AND offer_end_date AND id IN ("121211, 123341,151512,5145626 "); Now I want to cache the results of this query using memcache and so my question is How can I cache an query using memcache. I am currently using CURDATE() which cannot be used if we want to implement caching and so how can I get current date functionality without using CURDATE() function ?

    Read the article

  • Xenserver 5.6 SR_BACKEND_FAILURE_47 no such volume group, but it is there

    - by Juan Carlos
    I've looked everywhere (Google, here, a bunch of other sites), and while I have found people with similar problems, I couldn't find a single one with a solution to this. Last night our xenserver 5.6 box corrupted the /var/xapi/state.db, and I couldn't fix the xml, no matter what I did. After a good hour fiddling with the file, I figured it would be faster to just reinstall. The server had one 2tb hard drive running Xen and its VMs, and since Xen's install said it would erase the hard drive it was installed on, I plugged a new harddrive and installed Xen on it, without selecting any hard drives for storage. I Figured I could make it happen after install, using the partition on the old harddrive with all my VMs on it. After instalation finished and the system booted I did: #fdisk -l found the old partition at /dev/sda3 #ll /dev/disk/by-id found the partition at /dev/disk/by-id/scsi-3600188b04c02f100181ab3a48417e490-part3 #xe host-list uuid ( RO) : a019d93e-4d84-4a4b-91e3-23572b5bd8a4 name-label ( RW): xenserver-scribfourteen name-description ( RW): Default install of XenServer #pvscan PV /dev/sda3 VG VG_XenStorage-405a2ece-d10e-d6c5-ede2-e1ad2c29c68d lvm2 [1.81 TB / 204.85 GB free] Total: 1 [1.81 TB] / in use: 1 [1.81 TB] / in no VG: 0 [0 ] #vgscan Reading all physical volumes. This may take a while... Found volume group "VG_XenStorage-405a2ece-d10e-d6c5-ede2-e1ad2c29c68d" using metadata type lvm2 # pvdisplay --- Physical volume --- PV Name /dev/sda3 VG Name VG_XenStorage-405a2ece-d10e-d6c5-ede2-e1ad2c29c68d PV Size 1.81 TB / not usable 6.97 MB Allocatable yes PE Size (KByte) 4096 Total PE 474747 Free PE 52441 Allocated PE 422306 PV UUID U03Gt9-WtHi-8Nnu-QB2Q-c7BV-CO9A-cFpYWW # xe sr-introduce name-label="VMs" type=lvm uuid=U03Gt9-WtHi-8Nnu-QB2Q-c7BV-CO9A-cFpYWW name-description="VMs Local HD Storage" content-type=user shared=false device-config=:device=/dev/disk/by-id/scsi-3600188b04c02f100181ab3a483f9f0ae-part3 U03Gt9-WtHi-8Nnu-QB2Q-c7BV-CO9A-cFpYWW # xe pbd-create host-uuid=a019d93e-4d84-4a4b-91e3-23572b5bd8a4 sr-uuid=U03Gt9-WtHi-8Nnu-QB2Q-c7BV-CO9A-cFpYWW device-config:device=/dev/disk/by-id/scsi-3600188b04c02f100181ab3a483f9f0ae-part3 adf92b7f-ad40-828f-0728-caf94d2a0ba1 # xe pbd-plug uuid=adf92b7f-ad40-828f-0728-caf94d2a0ba1 Error code: SR_BACKEND_FAILURE_47 Error parameters: , The SR is not available [opterr=no such volume group: VG_XenStorage-U03Gt9-WtHi-8Nnu-QB2Q-c7BV-CO9A-cFpYWW] At this point I did a # vgrename VG_XenStorage-405a2ece-d10e-d6c5-ede2-e1ad2c29c68d VG_XenStorage-U03Gt9-WtHi-8Nnu-QB2Q-c7BV-CO9A-cFpYWW cause the VG name was different, but pdb-plug still gives me the same error. So, now I'm kinda lost about what to do, I'm not used to Xen and most sites I've been finding are really unhelpful. I hope someone can guide me in the right way to fix this. I cant lose those VMs (got backups, but from inside the guests, not the VMs themselves).

    Read the article

  • Clonezilla syntax error

    - by blsub6
    I'm using Clonezilla to try and get an image of a computer. The client boots to DRBL and then into Clonezilla just fine but after calculating the bitmap, it checks the disk space and gives me the error: Checking the disk space... (standard_in) 1: syntax error Something went wrong!!! Press "Enter" to continue...... I don't really know where to start with this one. Any suggestions?

    Read the article

  • Ubuntu + Raid on HP proliant DL 160 G6

    - by Adam Matan
    Hi, I'm, trying to install Ubuntu 8.04 Server on an HP Proliant DL160 G6. The HP hardware is certified by Ubuntu for the 9.04 version, which I can't install due to company policy. The problem is that Ubuntu would not recognize the RAID 1+0 disk configured by the BIOS. The raid creates one ~470GB disk from two 500GB physical disks. Any ideas? Adam

    Read the article

  • Strange DNS issue with internal Windows DNS

    - by Brady
    I've encountered a strange issue with our internal Windows DNS infrastructure. We have a website hosted on Amazon EC2 with the DNS running on Amazon Route 53. In the publicly facing DNS we have the wildcard record setup as an A record Alias pointing to an AWS Elastic Load Balancer sitting in front of our EC2 instances. For those who are not aware, the A record Alias behaves like a CNAME record, however no extra lookup is required on the client side (See http://docs.amazonwebservices.com/Route53/latest/DeveloperGuide/CreatingAliasRRSets.html for more information). We have a secondary domain that has the www subdomain as a CNAME pointing to a subdomain on the primary domain, which resolves against the wildcard entry. For example the subdomain www.secondary.com is a CNAME to sub1.primary.com, but there is no explicit entry for sub1.primary.com, so it resolves to wildcard record. This setup work without issue publicly. The issue comes in our internal DNS at our corporate office where we use the same primary domain for some internal only facing sites. In this setup we have two Active Directory DNS servers with one Server 2003 and one Server 2008 R2 instance. The zone is an AD integrated zone, but it is not the AD domain. In the internal DNS we have the wildcard record pointing to a third external domain, that is also hosted on Route 53 with an A record Alias pointing to the same ELB instance. For example, *.primary.com is a CNAME to tertiary.com, so in effect you have www.secondary.com as a CNAME to *.primary.com, which is a CNAME to tertiary.com. In this setup, attempting to resolve www.secondary.com will fail. Clearing the cache on the Server 2003 instance will allow it to resolve once, but subsequent attempts will fail. It fails even with a clean cache against the 2008 R2 server. It seems that only Windows clients are affected. A Mac running OSX Mountain Lion does not experience this issue. I'm even able to replicate the issue using nslookup. Against the 2003 server, with a freshly cleaned cache, I recieve the appropriate response from www.secondary.com: Non-authoritative answer: Name: subdomain.primary.com Address: x.x.x.x (Public IP) Aliases: www.secondary.com Subsequent checks simply return: Non-authoritative answer: Name: www.secondary.com If you set the type to CNAME you get the appropriate responses all the time. www.secondary.com gives you: Non-authoritative answer: www.secondary.com canonical name = subdomain.primary.com And subdomain.primary.com gives you: subdomain.primary.com canonical name = tertiary.com And setting type back to A gives you the appropriate response for tertiary.com: Non-authoritative answer: Name: tertiary.com Address: x.x.x.x (Public IP) Against the 2008 R2 server things are a little different. Even with a clean cache, www.secondary.com returns just: Non-authoritative answer: Name: www.secondary.com The CNAME records are returned appropriately. www.secondary.com returns: Non-authoritative answer: www.secondary.com canonical name = subdomain.primary.com And subdomain.primary.com gives you: subdomain.primary.com canonical name = tertiary.com tertiary.com internet address = x.x.x.x (Public IP) tertiary.com AAAA IPv6 address = x::x (Public IPv6) And setting type back to A gives you the appropriate response for tertiary.com: Non-authoritative answer: Name: tertiary.com Address: x.x.x.x (Public IP) Requests directly against subdomain.primary.com work correctly.

    Read the article

  • How to format as FAT32 from Windows 7/Vista

    - by Jack Ukleja
    What is the best way to format a USB drive with FAT32 (for Mac compatibility) from within Windows 7/Vista? I ask because the Disk Management only lets you pick exFAT (because the disk is over 32GB I believe). Doing it from the command line with diskpart doesn't seem to work either.

    Read the article

  • Why does only "network" appear in Startup Disks on my Mac?

    - by nbolton
    I have a Linux dual boot setup with my Mac (with Leopard). When I open System Preferences Startup Disk I only see "Network Startup" and no HDD or BOOTCAMP as expected. So now, annoyingly, because "Network Startup" is the only option, it tries to start using the network (the flashing globe) for a short while rather than booting directly into Mac OS X. Is there a way to either fix Startup Disk or manually hack this?

    Read the article

  • Failing Sata HDD

    - by DaveCol
    I think my HDD is fried... Could someone confirm or help me restore it? I was using Hardware RAID 1 Configuration [2 x 160GB SATA HDD] on a CentOS 4 Installation. All of a sudden I started seeing bad sectors on the second HDD which stopped being mirrored. I have removed the RAID array and have tested with SMART which showed the following error: 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 I have no clue what this means, or if I can recover from it. Could someone give me some ideas on how to fix this, or what HDD to get to replace this? Complete SMART report: Smartctl version 5.33 [i686-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: GB0160CAABV Serial Number: 6RX58NAA Firmware Version: HPG1 User Capacity: 160,041,885,696 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Tue Oct 19 13:42:42 2010 COT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 433) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 54) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0002 097 097 000 Old_age Always - 0 4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 152 5 Reallocated_Sector_Ct 0x0033 095 095 036 Pre-fail Always - 214 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 73109713 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15133 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 154 184 Unknown_Attribute 0x0032 038 038 000 Old_age Always - 62 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 189 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 190 Unknown_Attribute 0x001a 061 055 000 Old_age Always - 656408615 194 Temperature_Celsius 0x0000 039 045 000 Old_age Offline - 39 (Lifetime Min/Max 0/22) 195 Hardware_ECC_Recovered 0x0032 070 059 000 Old_age Always - 12605265 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 1 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 62 SMART Error Log Version: 1 ATA Error Count: 4645 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4645 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 02 7b 86 b1 ea 00 00:38:52.796 READ DMA ec 03 45 00 00 00 a0 00 00:38:52.796 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:52.794 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 04 79 86 b1 ea 00 00:38:49.935 READ DMA Error 4644 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 04 79 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:49.935 READ DMA Error 4643 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4642 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4641 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15131 - # 2 Short offline Completed without error 00% 15131 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • Gnome-mount alternative in Ubuntu 10.04 or how to mount partition with normal user rights

    - by easyrider
    Hi, i was using gnome-mount to automount drives but in lucid it was removed. So is there any alternatives in lucid except editing fstab and programs that do so? Gnome-mount is a program which mounts disks using the same facilities as when mounting a disk as a normal user through Nautilus. There is no need to setup mountpoints or filesystems. This is particularly interesting if you want to use the automatically created mountpoints instead of manually specifying them for each disk.

    Read the article

  • Detecting source of memory usage on a Linux box

    - by apeace
    I have a toy Linux box with 256mb RAM running Ubuntu 10.04.1 LTS. Here is the output of free -m: total used free shared buffers cached Mem: 245 122 122 0 19 64 -/+ buffers/cache: 38 206 Swap: 511 0 511 Unless I'm reading this wrong, 122mb is being used and only 84mb of that is disk cache. Here are all processes I'm running sorted by memory usage (ps -eo pmem,pcpu,rss,vsize,args | sort -k 1 -r): %MEM %CPU RSS VSZ COMMAND 5.0 0.0 12648 633140 node /home/node/main/sites.js 1.5 0.0 3884 251736 /usr/sbin/console-kit-daemon --no-daemon 1.3 0.0 3328 77108 sshd: apeace [priv] 0.9 0.0 2344 19624 -bash 0.7 0.0 1776 23620 /sbin/init 0.6 0.0 1624 77108 sshd: apeace@pts/0 0.6 0.0 1544 9940 redis-server /etc/redis/redis.conf 0.6 0.0 1524 25848 /usr/sbin/ntpd -p /var/run/ntpd.pid -g -u 103:105 0.5 0.0 1324 119880 rsyslogd -c4 0.4 0.0 1084 49308 /usr/sbin/sshd 0.4 0.0 1028 44376 /usr/sbin/exim4 -bd -q30m 0.3 0.0 904 6876 ps -eo pmem,pcpu,rss,vsize,args 0.3 0.0 888 21124 cron 0.3 0.0 868 23472 dbus-daemon --system --fork 0.2 0.0 732 19624 -bash 0.2 0.0 628 6128 /sbin/getty -8 38400 tty1 0.2 0.0 628 16952 upstart-udev-bridge --daemon 0.2 0.0 564 16800 udevd --daemon 0.2 0.0 552 16796 udevd --daemon 0.2 0.0 548 16796 udevd --daemon 0.0 0.0 0 0 [xenwatch] 0.0 0.0 0 0 [xenbus] 0.0 0.0 0 0 [sync_supers] 0.0 0.0 0 0 [netns] 0.0 0.0 0 0 [migration/3] 0.0 0.0 0 0 [migration/2] 0.0 0.0 0 0 [migration/1] 0.0 0.0 0 0 [migration/0] 0.0 0.0 0 0 [kthreadd] 0.0 0.0 0 0 [kswapd0] 0.0 0.0 0 0 [kstriped] 0.0 0.0 0 0 [ksoftirqd/3] 0.0 0.0 0 0 [ksoftirqd/2] 0.0 0.0 0 0 [ksoftirqd/1] 0.0 0.0 0 0 [ksoftirqd/0] 0.0 0.0 0 0 [ksnapd] 0.0 0.0 0 0 [kseriod] 0.0 0.0 0 0 [kjournald] 0.0 0.0 0 0 [khvcd] 0.0 0.0 0 0 [khelper] 0.0 0.0 0 0 [kblockd/3] 0.0 0.0 0 0 [kblockd/2] 0.0 0.0 0 0 [kblockd/1] 0.0 0.0 0 0 [kblockd/0] 0.0 0.0 0 0 [flush-202:1] 0.0 0.0 0 0 [events/3] 0.0 0.0 0 0 [events/2] 0.0 0.0 0 0 [events/1] 0.0 0.0 0 0 [events/0] 0.0 0.0 0 0 [crypto/3] 0.0 0.0 0 0 [crypto/2] 0.0 0.0 0 0 [crypto/1] 0.0 0.0 0 0 [crypto/0] 0.0 0.0 0 0 [cpuset] 0.0 0.0 0 0 [bdi-default] 0.0 0.0 0 0 [async/mgr] 0.0 0.0 0 0 [aio/3] 0.0 0.0 0 0 [aio/2] 0.0 0.0 0 0 [aio/1] 0.0 0.0 0 0 [aio/0] Now, I know that ps is not the best for viewing process memory usage, but that's because it tends to report more memory than is actually being used...meaning no matter how you look at it all my processes combined shouldn't be using near 122mb, even if you account for the disk cache. What's more, memory usage is growing all the time. I've had to restart my server once a week, because once my 256mb fills up it starts swapping, which it wouldn't do just for disk cache. Shouldn't there be some way for me to see the culprit?! I'm new to server admin, so please if there's something obvious I'm overlooking point it out to me. Just for good measure, the output of cat /proc/meminfo: MemTotal: 251140 kB MemFree: 124604 kB Buffers: 20536 kB Cached: 66136 kB SwapCached: 0 kB Active: 65004 kB Inactive: 37576 kB Active(anon): 15932 kB Inactive(anon): 164 kB Active(file): 49072 kB Inactive(file): 37412 kB Unevictable: 0 kB Mlocked: 0 kB SwapTotal: 524284 kB SwapFree: 524284 kB Dirty: 8 kB Writeback: 0 kB AnonPages: 15916 kB Mapped: 10668 kB Shmem: 188 kB Slab: 18604 kB SReclaimable: 10088 kB SUnreclaim: 8516 kB KernelStack: 536 kB PageTables: 1444 kB NFS_Unstable: 0 kB Bounce: 0 kB WritebackTmp: 0 kB CommitLimit: 649852 kB Committed_AS: 64224 kB VmallocTotal: 34359738367 kB VmallocUsed: 752 kB VmallocChunk: 34359737600 kB DirectMap4k: 262144 kB DirectMap2M: 0 kB EDIT: I had misinterpreted the meaning of free -m at first. But even so: the important thing is that my OS eventually begins to use swap memory if I don't restart my server, which disk caching wouldn't do. So where do I look to see what is using all this memory?

    Read the article

  • RAID options for a LAMP web server

    - by jetboy
    I'm due to set up a LAMP web server with four drives and a RAID controller to act as a web server. The drives are 146Gb SAS, and the machine has two quad core processors and 16Gb RAM. There will be very few write operations to the MySQL database, and I'll be using as much caching as possible to reduce disk I/O. Question is: Would I be better off splitting the drives into two RAID 1 arrays, splitting up sequential and random disk I/O, or would I get better overall performance putting them all in a single RAID 1+0 array?

    Read the article

  • Problem installing Cardbus/PCMCIA drivers (USB 2.0 2-port)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • SMPS stops when I plug in a SATA drive?

    - by claws
    Hello, Part 1: my first question is all the 4 wire power connectors (intended for hardisks/dvd drives not mother board) are same. Right? I've been using all of them same and I had no problem for years. Yesterday I borrowed a SATA disk from my friend and connected it my computer using Sata Power adaptor (4 wire) and when I switched on the computer. There were fumes coming out of the connector. I immediately turned it off (in just one second). I tested the voltages in the 4 wire power connector of my SMPS: They were 5.3v & 12.2V. I couldn't measure the current. But my SMPTS label reads: DC Output: 3.3v (25A) +5v (32A) -5v (0.3A) +12V (17A) -12V (0.8A) And the SATA hardisk label reads Input: +5v (0.72A) +12V (0.52A) I'm shocked! I never noticed this. Does the "sata power adaptor" scale down the current to required? If it doesn't, I've been connecting same way for years. I never had any problem. This is the first time I'm encountering it. Part 2: I wanted to return the drive to my friend. He has two hard disks, SATA & PATA. Its the SATA that I borrowed. When he usually switches on. The CPU fan starts & then stops for a sec and starts again and continues working. That was the earlier situation. I don't know why it stops & starts? Well, Now when I connect this SATA disk and switch ON the computer. CPU fan starts (just for an instant, not even a 0.5 sec) and stops. It doesn't start again, I mean the power from SMPS has stopped. But if I disconnect this SATA disk. It works fine. What seems to be the problem? I've no idea about why there were fumes or why his SMPS starts & stops giving power? What is its relation with the SATA disk connection?

    Read the article

  • external hard drive is no longer recognized, gives buffer I/O errors

    - by BioGeek
    Hi all, The external hard drive which contains all my photos and where I backed-up all my important documents is no longer recognized. It is a three month old 500GB Iomage Prestige Desktop Hard Drive. When I plug it in, it is recognised as a USB device, because it shows up when I type lsusb, but dmesg gives this error message. [19712.013250] usb 2-2: new high speed USB device using ehci_hcd and address 21 [19712.145347] usb 2-2: configuration #1 chosen from 1 choice [19712.147214] scsi25 : SCSI emulation for USB Mass Storage devices [19712.147514] usb-storage: device found at 21 [19712.147519] usb-storage: waiting for device to settle before scanning [19717.148978] usb-storage: device scan complete [19717.149527] scsi 25:0:0:0: Direct-Access ST350082 0AS PQ: 0 ANSI: 2 CCS [19717.151020] sd 25:0:0:0: Attached scsi generic sg2 type 0 [19717.151685] sd 25:0:0:0: [sdb] 976773168 512-byte logical blocks: (500 GB/465 GiB) [19717.160402] sd 25:0:0:0: [sdb] Write Protect is off [19717.160412] sd 25:0:0:0: [sdb] Mode Sense: 34 00 00 00 [19717.160418] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19717.165685] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19717.165691] sdb: sdb1 [19719.171808] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19719.171818] sd 25:0:0:0: [sdb] Attached SCSI disk [19737.430998] sd 25:0:0:0: [sdb] Unhandled sense code [19737.431007] sd 25:0:0:0: [sdb] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [19737.431016] sd 25:0:0:0: [sdb] Sense Key : Medium Error [current] [19737.431027] sd 25:0:0:0: [sdb] Add. Sense: Unrecovered read error [19737.431038] end_request: I/O error, dev sdb, sector 6160463 [19737.431050] Buffer I/O error on device sdb1, logical block 6160400 [19737.431060] Buffer I/O error on device sdb1, logical block 6160401 [19737.431067] Buffer I/O error on device sdb1, logical block 6160402 [19737.431075] Buffer I/O error on device sdb1, logical block 6160403 [19737.431082] Buffer I/O error on device sdb1, logical block 6160404 [19737.431088] Buffer I/O error on device sdb1, logical block 6160405 [19737.431096] Buffer I/O error on device sdb1, logical block 6160406 [19737.431102] Buffer I/O error on device sdb1, logical block 6160407 [19737.431114] Buffer I/O error on device sdb1, logical block 6160408 [19737.431121] Buffer I/O error on device sdb1, logical block 6160409 [19737.712183] sd 6:0:0:0: [sdb] Unhandled sense code [19737.712191] sd 6:0:0:0: [sdb] Result: hostbyte=DID_ERROR driverbyte=DRIVER_SENSE [19737.712200] sd 6:0:0:0: [sdb] Sense Key : Hardware Error [current] [19737.712210] sd 6:0:0:0: [sdb] Add. Sense: No additional sense information [19737.712222] end_request: I/O error, dev sdb, sector 0 [19737.712232] Buffer I/O error on device sdb, logical block 0 Neither does the external drive show when I use fdisk: jeroen@phalacrocorax:~$ sudo fdisk -l [sudo] password for jeroen: Disk /dev/sda: 160.0 GB, 160041885696 bytes 255 heads, 63 sectors/track, 19457 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x000341ad Device Boot Start End Blocks Id System /dev/sda1 * 1 18714 150320173+ 83 Linux /dev/sda2 18715 19457 5968147+ 5 Extended /dev/sda5 18715 19457 5968116 82 Linux swap / Solaris` I popped the disk out of the casing put it on a SATA connect internally and then tried the file recovery programs testdisk/photorec and SpinRite, but both failed because they couldn't recognize the external harddisk. Do I have any other options?

    Read the article

  • How to create .iso from Snow Leopard retail DVD

    - by user10580
    I have a legal copy of Snow Leopard on DVD (retail) which I am attempting to use to create a bootable flash drive. The software I have been directed to use requests a .iso file (as I am familiar with from other os installs), but when inserting the DVD into either Windows 7 or Ubuntu 9.10 the disk is recognized only as a "Windows Support" DVD, with materials to "support Apple hardware with Windows." This is eventually intended for a hackintosh attempt on an ASUS EEEPC 1000HE netbook. This is an install disk. Thanks

    Read the article

  • Apple: Time capsule, 2 questions

    - by Patrick
    1) Can I use time capsule as server ? Can I run operating systems on it ? 2) I'm using time machine with my mac with time capsule. Let's say my mac crashes, and I cannot use it anymore. Can i restore my mac disk on another laptop from time capsule ? In other words, can I have a perfect copy of my mac hard disk on another mac ? thanks

    Read the article

  • What Apache/PHP configurations do you know and how good are they?

    - by FractalizeR
    Hello. I wanted to ask you about PHP/Apache configuration methods you know, their pros and cons. I will start myself: ---------------- PHP as Apache module---------------- Pros: good speed since you don't need to start exe every time especially in mpm-worker mode. You can also use various PHP accelerators in this mode like APC or eAccelerator. Cons: if you are running apache in mpm-worker mode, you may face stability issues because every glitch in any php script will lead to unstability to the whole thread pool of that apache process. Also in this mode all scripts are executed on behalf of apache user. This is bad for security. mpm-worker configuration requires PHP compiled in thread-safe mode. At least CentOS and RedHat default repositories doesn't have thread-safe PHP version so on these OSes you need to compile at least PHP yourself (there is a way to activate worker mpm on Apache). The use of thread-safe PHP binaries is considered experimental and unstable. Plus, many PHP extensions does not support thread-safe mode or were not well-tested in thread-safe mode. ---------------- PHP as CGI ---------------- This seems to be the slowest default configuration which seems to be a "con" itself ;) ---------------- PHP as CGI via mod_suphp ---------------- Pros: suphp allows you to execute php scipts on behalf of the script file owner. This way you can securely separate different sites on the same machine. Also, suphp allows to use different php.ini files per virtual host. Cons: PHP in CGI mode means less performance. In this mode you can't use php accelerators like APC because each time new process is spawned to handle script rendering the cache of previous process useless. BTW, do you know the way to apply some accelerator in this config? I heard something about using shm for php bytecode cache. Also, you cannot configure PHP via .htaccess files in this mode. You will need to install PECL htscanner for this if you need to set various per-script options via .htaccess (php_value / php_flag directives) ---------------- PHP as CGI via suexec ---------------- This configuration looks the same as with suphp, but I heard, that it's slower and less safe. Almost same pros and cons apply. ---------------- PHP as FastCGI ---------------- Pros: FastCGI standard allows single php process to handle several scripts before php process is killed. This way you gain performance since no need to spin up new php process for each script. You can also use PHP accelerators in this configuration (see cons section for comment). Also, FCGI almost like suphp also allows php processes to be executed on behalf of some user. mod_fcgid seems to have the most complete fcgi support and flexibility for apache. Cons: The use of php accelerator in fastcgi mode will lead to high memory consumption because each PHP process will have his own bytecode cache (unless there is some accelerator that can use shared memory for bytecode cache. Is there such?). FastCGI is also a little bit complex to configure. You need to create various configuration files and make some configuration modifications. It seems, that fastcgi is the most stable, secure, fast and flexible PHP configuration, however, a bit difficult to be configured. But, may be, I missed something? Comments are welcome!

    Read the article

< Previous Page | 189 190 191 192 193 194 195 196 197 198 199 200  | Next Page >