Search Results

Search found 5885 results on 236 pages for 'monitor'.

Page 200/236 | < Previous Page | 196 197 198 199 200 201 202 203 204 205 206 207  | Next Page >

  • Windows 2008 R2 Servers Sending Arp Requests for IPs outside Subnet

    - by Kyle Brandt
    By running a packet capture on my my routers I see some of my servers sending ARP requests for IPs that exist outside of its network. For example if my network is: Network: 8.8.8.0/24 Gateway: 8.8.8.1 (MAC: 00:21:9b:aa:aa:aa) Example Server: 8.8.8.20 (MAC: 00:21:9b:bb:bb:bb) By running a capture on the interface that has 8.8.8.1 I see requests like: Sender Mac: 00:21:9b:bb:bb:bb Sender IP: 8.8.8.20 Target MAC: 00:21:9b:aa:aa:aa Target IP: 69.63.181.58 Anyone seen this behavior before? My understanding of ARP is that requests should only go out for IPs within the subnet... Am I confused in my understanding of ARP? If I am not confused, anyone seen this behavior? Also, these seem to happen in bursts and it doesn't happen when I do something like ping an IP outside of the network. Update: In response to Ian's questions. I am not running anything like Hyper-V. I have multiple interfaces but only one is active (Using BACS failover teaming). The subnet mask is 255.255.255.0 (Even if it were something different it wouldn't explain an IP like 69.63.181.58). When I run MS Network Monitor or wireshark I do not see these ARP requests. What happens is that on the router capturing I see a burst of about 10 requests for IPs outside of the network from the host machine. On the machine itself using wireshark or NetMon I see a flood of ARP responses for all the machines on the network. However, I don't see any requests in the capture asking for those responses. So it seems like maybe it is maybe refreshing the arp cache but including IPs that outside of the network. Also when it does this NetMon doesn't show the ARP requests?

    Read the article

  • my X server doesn't load a module called "glx", but my video drivers seem to be installed

    - by rumtscho
    I just got a new, very wide monitor (2560x1440) and there is no sense maximizing my applications. So I installed Compiz Config Settings Manager and enabled Grid. Nothing happened, the shortcuts don't move application windows. Went to System - Preferences - Appearance, the Visual effects tab. It at "disabled". When I try to set them to "normal" or "extra", a message box appears telling me that it's searching for video drivers, then disappears, and I get an error message "Desktop effects could not be enabled". I opened Xorg.0.log, and had errors there: (EE) Failed to load /usr/lib/xorg/modules/extensions//libglx.so (II) UnloadModule: "glx" (EE) Failed to load module "glx" (loader failed, 7) (II) LoadModule: "extmod" Going to Administration - System - Hardware drivers, it said that there are no available and/or installed hardware drivers. But apt-get said that it cannot install nvidia-glx-185, as it is already installed. Googling my error message suggested that I install and run something called envyng. This let me install the nvidia drivers again, and now I can see in the Hardware Drivers window that they are installed and active. But the error message in Xorg.0.log remains, and I still cannot enable the Compiz effects or use Grid. Now, I don't have enough Linux experience to understand if this is a single cause-effect-chain of problems, or three independent ones, but I'd appreciate help for any of them. I am running Ubuntu 9.10, the video card is a GeForce 7600GS.

    Read the article

  • Tri-head linux system with Xmonad: is it possible to have HW acceleration

    - by progo
    What means there exists to have three monitors, all controlled by Xmonad and have hardware 3D acceleration as well? I had the pleasure of using three monitors earlier this year, and while Xmonad and Xinerama handle three monitors easily, I had to throw in an extra display driver, and also let go of Nvidia's own TwinView (which is a hack on Xinerama). This left me with no HW acceleration and some flickering as double buffering wouldn't work with certain applications. However, the three monitors handle so beautifully that I had hard time coming back to two. I understand the easiest way to achieve HW-accelerated tri-head combo is to split into two Xorgs. I wouldn't be able to switch windows between the Xorgs, so I'm not really into this solution. What's more, having a cheap and old PCI card along with even slightly better PCIe seemed to slow things down. Even if I occasionally disabled the third monitor from Xorg configure, I couldn't get HW acceleration to work. Only after I physically disconnected the old PCI card, I could get the games back in business. Would a Matrox Dual/Tri-head2go and a powerful Nvidia GPU do the trick? I understand Xmonad can be configured to "believe" that a "single" (as Dualhead2Go will merge) 3360x1050 display is actually two different ones? So that Xmonad's Mod-w and Mod-e would work properly there.

    Read the article

  • Oracle 10g for Windows does not start up on system boot

    - by Mike Dimmick
    We have an Oracle 10g Enterprise Edition installation (10.2.0.1.0) on a Windows Server 2003 virtual machine. It was initially created with Virtual Server 2005 R2 SP1 but has now been migrated to Windows Server 2008 Hyper-V. The services start on system boot, but the instance does not start up. This problem was actually occurring on Virtual Server after a migration from one server to another, but I managed to fix it then with: oradim -edit -sid ORCL -startmode auto However, this now has no effect. oradim.log (in %OracleHome%\database\oradim.log) says: Thu Jun 10 14:14:48 2010 C:\oracle\product\10.2.0\db_3\bin\oradim.exe -startup -sid orcl -usrpwd * -log oradim.log -nocheck 0 Thu Jun 10 14:14:48 2010 ORA-12560: TNS:protocol adapter error sqlnet.log in the same folder has: Fatal NI connect error 12560, connecting to: (DESCRIPTION=(ADDRESS=(PROTOCOL=BEQ)(PROGRAM=oracle)(ARGV0=oracleorcl)(ARGS='(DESCRIPTION=(LOCAL=YES)(ADDRESS=(PROTOCOL=beq)))'))(CONNECT_DATA=(SID=orcl)(CID=(PROGRAM=C:\oracle\product\10.2.0\db_3\bin\oradim.exe)(HOST=ORACLE-VM)(USER=SYSTEM)))) VERSION INFORMATION: TNS for 32-bit Windows: Version 10.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 32-bit Windows: Version 10.2.0.1.0 - Production Time: 10-JUN-2010 14:14:48 Tracing not turned on. Tns error struct: ns main err code: 12560 TNS-12560: TNS:protocol adapter error ns secondary err code: 0 nt main err code: 530 TNS-00530: Protocol adapter error nt secondary err code: 2 nt OS err code: 0 The ORA_ORCL_AUTOSTART registry value is set to TRUE, so it should be auto-starting - and you can see that it's trying to. The problem also occurs when stopping and restarting the OracleServiceORCL service. I've enabled SQL*Net tracing which shows: [10-JUN-2010 15:09:33.919] snlpcss: entry [10-JUN-2010 15:09:34.419] snlpcss: Unable to spawn Oracle oracle (DESCRIPTION=(LOCAL=YES)(ADDRESS=(PROTOCOL=beq))) orcl, error 2. [10-JUN-2010 15:09:34.419] snlpcall: exit On a hunch that error 2 is Windows error 2 (file not found) I tried restarting the service with Process Monitor watching oradim.exe, but this appears to delay things just enough that it always works. Right now I have a horrible hack where I've created a Scheduled Task to run oradim -startup -sid ORCL when the Administrator account logs on, and set the VM to auto-logon. I'd still like to work out why it's not working.

    Read the article

  • tail -f and then exit on matching string

    - by Patrick
    I am trying to configure a startup script which will startup tomcat, monitor the catalina.out for the string "Server startup", and then run another process. I have been trying various combinations of tail -f with grep and awk, but haven't got anything working yet. The main issue I am having seems to be with forcing the tail to die after grep or awk have matched the string. I have simplified to the following test case. test.sh is listed below: #!/bin/sh rm -f child.out ./child.sh > child.out & tail -f child.out | grep -q B child.sh is listed below: #!/bin/sh echo A sleep 20 echo B echo C sleep 40 echo D The behavior I am seeing is that grep exits after 20 seconds , however the tail will take a further 40 seconds to die. I understand why this is happening - tail will only notice that the pipe is gone when it writes to it which only happens when data gets appended to the file. This is compounded by the fact that tail is to be buffering the data and outputting the B and C characters as a single write (I confirmed this by strace). I have attempted to fix that with solutions I found elsewhere, such as using unbuffer command, but that didn't help. Anybody got any ideas for how to get this working how I expect it? Or ideas for waiting for successful Tomcat start (thinking about waiting for a TCP port to know it has started, but suspect that will become more complex that what I am trying to do now). I have managed to get it working with awk doing a "killall tail" on match, but I am not happy with that solution. Note I am trying to get this to work on RHEL4.

    Read the article

  • Is there a way to run CUDA applications with the CUDA device being a secondary adapter?

    - by Slartibartfast
    I've been trying to run a CUDA program on a remote computer which has Windows 7 installed. The GPU is GeForce GTX 480. One of the problems I've been facing is that, the computer has two adapters, 1) Standard VGA Adapter 2) NVIDIA GeForce GTX 480 Even though this shows in the device manager. The desktop uses the standard VGA Adapter. I'm assuming this is because the Standard VGA is the primary adapter. Also the device manager shows that the monitor is connected to the standard VGA Adapter. In this scenario if i try to run any CUDA application it fails to recognise a CUDA capable device. Is it necessary for the NVIDIA adapter to be the primary one? Or is there any way to use CUDA when the graphics card is a secondary adapter. I've seen a few posts in the NVIDIA forums on this before, one suggests using another low cost NVIDIA card as the primary adapter, but that is currently not an option. I couldn't find any other solutions. Thanks I tried running the deviceQuery test from the NVIDIA GPU Computing Samples. This was the result i obtained CUDA Device Query (Runtime API) version (CUDART static linking) cudaGetDeviceCount FAILED CUDA Driver and Runtime version may be mismatched FAILED The driver version I'm using is 263.06. The CUDA version is 3.2 I ran the same test on my desktop which also has windows 7 and a GeForce GTX 465. The CUDA toolkit version is 3.2. The driver version was the same and the test passed, although it failed with an older driver.

    Read the article

  • Mac OS Leopard: SyncServer process constantly using 100% CPU

    - by macca1
    I am running Leopard that I upgraded from Tiger. I've been noticing that every once in a while the SyncServer process starts up and eats up all the CPU. The fans will start going at full blast and the laptop will slow down to a crawl. I need to force quit the process from Activity Monitor to get it under control. It disappears for a while, but eventually gets started again. I do have an iphone as well that I sync so I'm wondering if syncServer might be an apple process checking for my phone plugged in. Edit: Tried iSync and the manual resetsync as suggested, but got this output: Vince-2:~ vince$ /System/Library/Frameworks/SyncServices.framework/Versions/A/Resources/resetsync.pl full 2010-03-12 08:03:50.230 perl[176:10b] SyncServer is unavailable: exception when connecting: connection timeout: did not receive reply PerlObjCBridge: NSException raised while sending reallyResetSyncData to NSObject object name: "ISyncServerUnavailableException" reason: "Can't connect to the sync server: NSPortTimeoutException: connection timeout: did not receive reply ((null))" userInfo: "" location: "/System/Library/Frameworks/SyncServices.framework/Versions/A/Resources/resetsync.pl line 16" ** PerlObjCBridge: dying due to NSException Vince-2:~ vince$ And during that syncServer started spinning up 95-100% just like it always does.

    Read the article

  • Are These Parts compatible?

    - by ell
    I have never assembled a PC before, although I have taken an old one apart and replaced a few parts in others here and there so I have (very) limited experience. I have been looking to make a pc and here are the parts I might buy: Foxconn P45AL Intel P45 (Socket 775) DDR2 Motherboard (with onboard sound I believe) Gigabyte GeForce GTX 460 OC 768MB GDDR5 PCI-Express Graphics Card Already have 2 1gb sticks of dual channel DDR2 memory Intel Core 2 Quad Q8400 LGA775 'Yorkfield' 2.66GHz 4MB-cache Processor Samsung SpinPoint F3 1TB SATA-II 32MB Cache Hard Drive Antec Dark Fleet Series DF10 Gaming Enclosure – Black I already have monitor, mouse, keyboard and DVD/CD drive Akasa Freedom Power 1000W Modular Power Supply I have never done this before so feel free to laugh at me for getting something obvious wrong, forgetting a vital component etc. but is all of this compatible? And have I gone overkill on the PSU, if so, please recommend one. Thanks in advance, ell. EDIT: Added PSU which I forgot to mention EDIT: I would be using this to surf the internet, write e-mails, chat, word process, play games such as team fortress 2 & spring rts (at highest graphics hopefully), some 3d modelling in blender, some opengl programming, and image editing in GIMP.

    Read the article

  • Backing up SQL NetApp Snapshots using TSM

    - by WerkkreW
    In our environment we have a 3 node SQL 2005 Cluster which is on NetApp storage. We are currently using SMSQL (NetApp SnapManager for SQL) to take Snapshot backups of the data. This works great, but due to some audit requirements we are also forced to maintain some copies on tape. We have used NDMP in other places across the enterprise but we do not want to use it in this specific instance. Basically what I need to do is, get the most recent snapshot copy of the databases on tape, via Tivoli Storage Manager (TSM). What I have done is, obtained a basic Windows Server 2003 VM with SnapDrive installed, which is SAN attached and zoned to the NetApp, and I have written a batch file to do the following: Mount the latest __RECENT snapshot lun to the host, using a specific drive letter Perform a TSM based incremental backup Dis-mount the LUN This seems to work fine, except sometimes the LUN's do not mount due to some sort of timeout. Also, due to my limited knowledge of windows batch scripting, I have no way to monitor the success or failure of these backups since I do not know how to send a valid return code back to the TSM scheduling service. Is there a more efficient/elegant way to accomplish this without NDMP?

    Read the article

  • Is .htaccess slowing down my dedicated server?

    - by David Robles
    First of all, I consider myself more a programmer than a servers guy. I have a website where I receive about 3,000 visits per day, which I think is a lot less than the max capacity for a dedicated server. However, I've noticed that the connection to the website is pretty slow, e.g., to load images, to connect to it via SSH, etc. I configured .httaccess recently to avoid hotlinking to images in my server (i.e. .jpg, .gif and .png), and I was wondering if that could be slowing down my website. This is the configuration that I have: # BEGIN WordPress <IfModule mod_rewrite.c> RewriteEngine On RewriteBase / RewriteEngine on RewriteCond %{HTTP_REFERER} !^$ RewriteCond %{HTTP_REFERER} !^http://www.mysite.com/.*$ [NC] RewriteCond %{HTTP_REFERER} !^http://www.mysite.com$ [NC] RewriteRule .*\.(jpg|jpeg|gif|png|bmp|swf)$ http://www.google.com/ [R,NC] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /index.php [L] </IfModule> # END WordPress I found some code to do that in google, and I just copied to .htacces since I'm not an expert in apache. It works, but I don't know if that is the best way to do it. How can I see if that is the reason why the server is slow? Are there any tools to monitor it? What would you do guys? Thanks in advance!

    Read the article

  • Is it a good idea to run Redmine using Webrick through Nginx?

    - by Rohit
    The task here is to get Redmine setup for a small (<20) team. There may be a few users who would access the setup as business clients. I am familiar with setting up PHP for Apache, and recently, Nginx. I am not familiar with Ruby, Ruby-On-Rails, etc. I prefer to use the OS's (Ubuntu Linux LTS) package manager to install the different components as it takes care of dependencies and updates. I have setup Nginx with PHP-FPM successfully and am struggling with Redmine. As suggested here, I got Redmine running on port 3000. # /etc/init/redmine.conf # Redmine description "Redmine" start on runlevel [2345] stop on runlevel [!2345] expect daemon exec ruby /usr/share/redmine/script/server webrick -e production -b 0.0.0.0 -d And using the Nginx config on this page, I used Nginx to proxy requests to Webrick. server { listen 80; server_name myredmine.example.com; location / { proxy_pass http://127.0.0.1:3000; } } This works well locally. I wanted some opinions before trying this out on the live box (a 256 MB VPS). Further, should I use something like monit to monitor webrick for failure?

    Read the article

  • Loss of network connectivity when playing video on Optoma HD180 projector

    - by Jeff Fohl
    Hi Folks - New to Super User, so I hope this question fits in with the guidelines. Very strange problem I am having, and I am at a loss as to how to continue troubleshooting this one. The basic problem is that when I attempt to watch streamed video on a particular display device (an Optoma HD180 projector), my network connectivity drops like a stone to barely measurable levels. This is my setup: I have a Dell H2C 730x running Windows 7 64bit. This particular computer has two ATI Radeon HD 4800 video cards. I have two Samsung 22" monitors connected to one card, and an Optoma HD180 digital projector connected to the other card via an HDMI cable. My internet connection is normally a reliable 6Mbps. The problem I am having occurs when I stream video (or even just browse the web) on the Optoma Projector. When I do this, my internet connection drops to practically zero (just a few kilobits per second). When I move the browser away from the projector, and over to one of my Samsung monitors, the internet connection comes right back. Note that the Optoma projector is on and enabled as a third monitor all this time. I can move the mouse around on the projector without triggering the problem. I tried pinging my router when I was playing a movie on one of the monitors, and I get a 1 millisecond response. However, when I have the movie playing on the Optoma projecter, pinging the router gives me response times in the hundreds of milliseconds, or times out completely. So, it clearly is something local to my machine - and not some sort of throttling occurring down the line. I would think that it is possibly something to do with the HDMI driver conflicting somehow with my network driver (which is a USB-based wireless connection). This one has me really stumped. Anyone have any ideas?

    Read the article

  • Laptop battery holds charge, but won't charge any more.

    - by Jeff
    Ok, I'm sure I will need to replace either my battery or my AC adapter, but would rather not buy one if the other is the problem. My problem is. I have a Sager laptop that gets quite a bit of use. The charging has always been a little bit odd. If I was in the process of using it, it would charge just fine and stay On AC power. If I left it alone, however(power settings to ONLY turn off the monitor) in either Ubuntu or Windows 7 it decides that it didn't want to use AC power anymore and would just start draining the battery until it died. Now, suddenly, it won't charge at all. The capacity was great up to this point which happened in an instant. It will recognize the battery but won't see the AC power if plugged in while the battery is in. I can power up the laptop without the battery and it works fine. If I plug in the battery while powered up it will claim it's charging it, but it stays at the same percentage. If I unplug the power, it will switch over to Battery fine, but I have to power down and unplug the battery to get it back on AC power. I've had dying/dead batteries before but they typically won't hold a full charge anymore but it still winds up to 100% then drops quickly when unplugged. This seems more like a chip problem in the battery to me, but I'm not sure. Any ideas?

    Read the article

  • Production monitoring for EC2 instances

    - by Janine
    I'm setting up my first production instance on EC2 and want to make sure I have all necessary monitoring in place. There are three different types of things I want to monitor: Is the instance running? EC2 instances can be terminated without warning if the underlying hardware fails, and as far as I know they aren't automatically restarted. So if not, start it back up. Is UNIX running properly? This is the usual stuff about CPU load, disk space, etc. Is the website responding? If not, restart it. I initially set up Nagios on a physical server outside the cloud, but it is really only helpful for item 2. It can tell me if the instance is gone or if the website is not responding, but as far as I can tell it can't execute any commands to fix the situation. My Googling on this subject has yielded a plethora of options - Cacti, Monit, God, Ganglia, and probably more I'm forgetting now. I don't have time to research them all. I am aware of Amazon's Cloudwatch but it doesn't seem to do anything that my Nagios installation doesn't already do. If you already have something like this in place, can you please share what has worked well for you?

    Read the article

  • Walkthrough/guide building aplication server for multi tenant web app [on hold]

    - by Khalid Adisendjaja
    The web app will detect a subdomain such as tenant1.app.com, tenant2.app.com, etc to identify tenant environment, each tenant environment will have a different database credential (port,db name,etc) but still connecting to the same database server. Each tenant should use app.com for their main domain, using their own domain is prohibitted. Each tenant will have their own rest api endpoint such as tenant1.app.com/api/v1/xxxx, tenant2.app.com/api/v1/xxxx, tenant3.app.com/api/v1/xxxx I've come to a simple solution by setting a wildcard subdomain (*.app.com) on webserver Apache/Nginx vhost configuration file. I have googled so many concept for building a multi-tenant app server but still don't understand how to really done it, what is the right way to do it and what is actually required to do this task. So I've come to this questions, Do I need a proxy server, dns masking, etc.. How to monitor each tenants activity What about server performance, load balancing, and scalability How to setup ssl certificate for each tenant what about application cache for each tenant Is it reliable to use the setup for production etc ... I have a very litte experience on server infrastructure, so I'm looking for a DIY walkthrough, step by step guide, or sophisticate solution ready to implemented for production

    Read the article

  • Why do fonts sometimes look "fat" on Mac OS X?

    - by jtimberman
    Sometimes when resuming from suspend, the fonts in Mac OS X look "fatter" than normal. Unfortunately right now I can't get my Macbook Pro to exhibit the "normal" behavior for comparison, it has been abnormal yesterday and today. If I can get screenshots of what I think is 'normal', I'll add them. "Fixing" this has been random. I use an external monitor, and sometimes unplugging it and plugging back in, or even turning it off and back on has worked. Sometimes with the display attached (or not) detecting displays works. Sometimes logging out or rebooting entirely is what it takes. Displays used: Macbook Pro 15" built-in display Dell 27" LCD (2009 model) Software where I see this happen, at least most noticably: Firefox (screenshots below) iTerm Things MacIrssi (screenshots below) I am using Mac OS X 10.5.8. "Abnormal" view from MacIrssi with Inconsolata 16 pt. image full size "Abnormal" view from Firefox. Finally got it to switch back, though after resuming from suspend its back to "fat" :-(. image full size And 'normal' in Firefox:

    Read the article

  • Windows 7 mapped drive kicking off OS X users

    - by Collin White
    I've mapped a network drive on my Windows 7 PC at my office. The windows machine has a few TB of storage that is being accessed by my development team (all running mac os 10.7). The share seems to work fine for a little while but will timeout and kick the mac users off and sometimes disallows a connection on the next attempt. Restarting the windows machine fixes the problem. I've tried this tutorial as well as setting the maximum session length in the Local Security Policy section to 99999 (I discovered 0 did not mean unlimited, only a 'reasonable ammount of time') anyway, the setting is now for ~208 days which is sufficient (see attached). I'm having trouble debugging this in general so if anyone has some pointers I'm all ears. This is a intermittent issue which in my opinion are the hardest kinds to debug. If anyone knows of how I might monitor connections from the PC that would also be pretty cool. Previously the files were hosted on a mac mini and everything was working just fine (the mini just didn't have the ability for the storage capacity we needed) so I believe it is some windows setting that is kicking users off. Anyway, thanks for reading.

    Read the article

  • Screen Flickering: Hardware or Software?

    - by Wesley
    I have a Samsung N120 netbook (upgraded to 2GB DDR2 RAM) and there has been a screen flickering issue for some time now. However, I have not been able to accurately determine whether it is a software or hardware issue. Here are some of the symptoms: The flicker is white-colored and shows up as vertical lines. Flickering or not, there may be occasionally some random blue patterns (no image distortion) The screen tends to flicker more when the screen is not tilted back all the way. When tilting the screen back and forth, the screen will usually flicker. Some images on the screen may randomly distort without full-on flickering. The screen will flicker only on certain websites, but not on others. A certain part of a webpage may constantly be distorted randomly, even when scrolling. While flickering, the mouse will not move though I'm moving my finger along the touchpad. A connected external monitor does not have any problems. The flickering is completely random and does not seem to follow any CPU/GPU usage trends. Flickering usually gets worse when the screen brightness is turned higher. There will be flickering on battery and while plugged in. Search up "Samsung N120 - Screen Flickering" on YouTube for an idea of what the flickering looks like. However, there is no visible distortions and the flickering seems to stop when the screen has dimmed. Since the problems started, I tried formatting and using Windows 7, then formatted again and went back to Windows XP. The screen was also replaced sometime during this past summer. The uninstallation of the Samsung Battery Manager (on the original install of XP) seemed to reduce the flicker partially, but eventually got worse. So, what could possibly be the problem?

    Read the article

  • My Computer hangs for a few minutes just after startup, and then is fine.

    - by EvilChookie
    So I just built myself a reasonably beefy computer, and I installed Windows 7 on it. However, I start the machine up each morning and within a few minutes, the computer will semi hang. That is the mouse is responsive, and most of the time I can open task manager, or a new tab in Chrome. Occasionally windows will be labelled as 'Not responding'. Then, the machine will get over it's problem, and will be nice and quick until I turn it off. Here's my specs: CPU: AMD Phenom-II X4 955 Black (Quad Core, 3.2ghz) RAM: 4GB of DDR3 1300 MOBO: ASUS M4A785T-M (Latest BIOS) HARD DRIVES: 2x1TB Western Digital Caviar Blacks in RAID-0. OS: Windows 7 Ultimate x64. GPU: ASUS GT240 1GB. I believe this issue relates to the RAID array, as I didn't have the lockup problem before I created the array. I purchased a second drive and reformatted after creating a RAID array, since the single drive was a little on the pokey side (compared to the rest of the computer). What I have tried: Updated Raid Drivers Malware checks Windows Updates Unecessary Services CPU and Disk activity appears to be low (via Resource Monitor) No strange errors in the error log. Any thoughts?

    Read the article

  • Replacing compiz/metacity with openbox reduces workspaces to 1

    - by Brian
    I like to use the GNOME desktop, but I prefer to replace its window manager with openbox, with 4 workspaces. However, when I run openbox --replace, the number of workspaces available drops to 1. If I go into obconf, workspaces is still configured to be 4 (~/.config/openbox/rc.xml shows the same). I can get the workspaces to reappear by changing the value in obconf to anything else, and then back to 4. I have just been dealing with this problem since Ubuntu 9.04 (now up to 10.10) since I don't reboot very often. But it's really annoying to have to reset my workspaces whenever I do have to reboot. Changing the value in rc.xml and running openbox --reconfigure does not seem to have any effect. So what is obconf doing that I'm not (sends a dbus message perhaps [EDIT: watching with dbus-monitor I see no messages when changing the workspaces value in obconf])? I was hoping there would be a cleaner way to change the window manager than just running openbox --replace at login. So my questions are: Is there a better way to specify an alternate window manager (i.e. a way that doesn't cause the workspaces to break)? If not, how can I automatically set the number of workspaces back to 4? Update: I finally got around to trying what I commented on MrShunz's answer (adding WINDOW_MANAGER=/usr/bin/openbox to ~/.gnomerc). But the effect is the same as openbox --replace.

    Read the article

  • Compaq motherboard CQ60 AMD - nvidia chipsed graphic problem

    - by Dritan
    Hi! It nice to have read that you solved this problem this way. I have 2 laptops Compaq CQ60 AMD Athlon with Nvidia graphic cards. the first one is new, when i press power button, it lights up only the ON led in front and nothing else, no fan working, blank screen, no beep.. I don't know what may be the problem. When I put on power adaptor, it lights up only the side power led near dhe power adapter plug but it doesn't light up the front led one. the second one have this problem that it spins the fan, light power and On led, but it doesn't show nothing on the screen blank (even with external monitor). In this case it maybe this problem of the Nvida Graphic Chip and it may need a reflow. I have an hot air station, but I don't know if I should try this or the oven one. Please can you give me any suggestion what to do to solve this. I have read that the solution of the Oven method is just temporary,maximum of three months, do you have the same experience about this? Any suggestion is wellcome.

    Read the article

  • Amazon AWS VPN how to open a port?

    - by Victor Piousbox
    I have a VPN with public and private subnets; I am considering only public subnet for now. The node 10.0.0.23, I can ssh into it. Let's say I want to connect to MySQL on the node using its private address: ubuntu@ip-10-0-0-23:/$ mysql -u root -h 10.0.0.23 ERROR 2003 (HY000): Can't connect to MySQL server on '10.0.0.23' (111) ubuntu@ip-10-0-0-23:/$ mysql -u root -h localhost Welcome to the MySQL monitor. Commands end with ; or \g. --- 8< --- snip --- 8< --- mysql> The port 3306 is not reachable if I use the private IP? My security group allows port 3306 inbound from 0.0.0.0/0 AND from 10.0.0.0/24. Outbound, allowed all. The generic setup done by Amazon through their wizard does not work... I add ACL that allows everything for everybody, still does not work. What am I missing?

    Read the article

  • Time sync fails on Hyper-V VM, but succeeds when I log in as a domain user

    - by Richard Beier
    We have a Windows Server 2003 SP2 VM running on Hyper-V (Server 2008 R2 host). The VM has Hyper-V time synchronization enabled. I noticed that the time on the VM was fast by around 25 minutes. I saw the following in the event log: The time provider NtpClient is configured to acquire time from one or more time sources, however none of the sources are currently accessible. No attempt to contact a source will be made for 15 minutes. NtpClient has no source of accurate time. The time provider NtpClient cannot reach or is currently receiving invalid time data from ourdc.ourdomain.local (ntp.d|192.168.2.18:123-192.168.2.2:123). Time Provider NtpClient: No valid response has been received from domain controller ourdc.ourdomain.local after 8 attempts to contact it. This domain controller will be discarded as a time source and NtpClient will attempt to discover a new domain controller from which to synchronize. I had been logged in as a local user. (We have an old app that runs on this VM - it requires a user to be logged in at all times, and we use a non-domain user account for this.) When I logged in as a domain user, the clock almost immediately corrected itself. Running "w32tm /monitor" and "net time" as the domain user showed no errors, and indicated that our domain controller was the time source. Does anyone know what might cause this, and why logging in under a domain account fixes the problem? I'm wondering if the time will start to drift again. Thanks for your help, Richard

    Read the article

  • MacBook Air i5 4 GB RAM shows screen tearing when scrolling in browsers

    - by Sandro Dzneladze
    I see screen tearing pretty often while scrolling webpages up and down, and it has been like this from day 1. But now I purchased an external monitor which is huge (23 inches compared to the Mac's 11), and the effect is more visible. It is driving me nuts and giving me headaches. I wonder if you see the same. I was reading a lot about this problem, and it seems to be present on MacBook Pros as well? Can someone confirm I'm not alone? In other words: I'm deciding weather to go through warranty repair, or if it makes no sense if all of theme exhibit same behavior. It is shame to see this beautiful machine with an insane price tag to be lagging when browsing web, when the processor is just sitting there idle at 4-12%! This is an example I found on Wikipedia that more or less describes what happens when I scroll up down. The effect is not so pronounced and clears when I stop scrolling, but it is sure annoying the hell out of me. Firefox is tearing like hell, Chrome less, Safari exhibits jagged scrolling but less tearing compared to Chrome and Firefox. With synthetic benchmarks I don't see any problems with hardware. But this is not particularly revealing.

    Read the article

  • Samsung laptop randomly shuts down

    - by Dmatig
    I've rewritten this question because it turned into an indecipherable mess. I have a Samsung R560 laptop that is overheating, and shutting itself down under load consistantly. Thank you quickcel for reccomending me Speedfan to monitor my temps. Here they are (Load / Idle): (Ignore "Temp1 and Temp2", whatever sensors they are they'd always random, pretty sure they're broke). The load temperature is after just 5 minites of playing Fallout 3 - another 5 minutes and it (the GPU - 9600M GS) consistantly breaches the mid 90's then shuts down, so it's hard to get a good picture of it. I'm looking for some solution or way to decrease these temperatures, because they seem far too high even idle. I've tried: Opening up the case and clearing of all dust with compressed air. Updating drivers for my Graphics card Have purchased and am using a notebook cooler I don't want to: Undervolt / underclock (defeats the point of having a more expensive card) Use lower power / performance settings (again, i might as well have bought something cheaper) Is there anything else i can try (software or inexpensive hardware) that can help me fix this? Has anybody had a Samsung laptop and knows if this can be sorted under my warranty, and the turnaround time of sending it off (UK?)(it has always ran hotter than it should, but now at 6 months old is getting hot enough to power off)

    Read the article

< Previous Page | 196 197 198 199 200 201 202 203 204 205 206 207  | Next Page >