  • HP Procurve Issue Passing Multiple VLANs over a link

    - by MichaelRwat
    Just to start off with I am a Cisco guy that got placed into an HP project. Basic topology overview from outside in: ASA 5505 with two Ethernet connections to a 2910-24 port switch. This switch is then (Cisco Trunking) to a 2626 switch passing vlan (1 untagged and 100 tagged)between them. I created SVI's on each of the switches for both VLAN's for testing purposes. I can not get vlan 100 to pass across this link. I also have trunks configured to AP's off of the switch and can not ping the vlan 100 BVI on the AP's but can reach the vlan 1 BVI. Port 25 on Access layer (2626) connects (trunks) with port A1 of 2610. STP is not running at all on any switch (this is not my network I can't change this nor did I design this) Distribution Sw: MP1-0# show run ip default-gateway 10.100.100.100 vlan 1 name "DATA" untagged 1-22,24-A1,B1 ip address 10.100.100.6 255.255.255.0 no untagged 23 exit vlan 100 name "GUEST" untagged 23 tagged 24-A1 ip address 10.100.102.6 255.255.255.0 exit Access Sw: ip default-gateway 10.100.100.100 vlan 1 name "DEFAULT_VLAN" untagged 1-26 ip address 10.100.100.5 255.255.255.0 exit vlan 100 name "GUEST" ip address 10.100.102.5 255.255.255.0 tagged 15,25 exitt From the ASA I can ping the vlan 100 address of the 2610 but not the 2626 (10.100.102.6)[Not passing the "trunk"] If I plug into an access port vlan 100 of the 2626 I can ping the SVI for vlan 100 as intended. I can not ping across the "trunk" over vlan 100 but I can across vlan 1. There may be something obvious I'm missing but please review my configuration and thank you for the assistance.

    Read the article

  • Issues getting a Cisco WLC 5508 to find AIR-LAP1142N

    - by user95917
    hoping someone can help me with a problem here. I'm attempting to setup a test (loan from Cisco) wireless network. Here's what i've got/done: 5508 Controller - Service Port IP set to 10.74.5.2 /24. Management IP set to 10.74.6.2 /24 with a default gateway of 10.74.6.1. Virtual IP set to 1.1.1.1. Copper SFP in slot 7, CAT5 (known good) going from there to port 1/0/47 on the switch. Green lights on both ends. 2960-S Switch - Vlan1 - 10.74.6.1 /24. dhcp pool 10.74.6.0 /24, default router 10.74.6.1. excluded-address 10.74.6.1, 10.74.6.2. 1/0/4 on the switch is set to switchport mode access and no shut. 1/0/47 on the switch is setup to switchport mode trunk and no shut. 1/0/4 has a CAT5 (known good) cable going from there to the AP. When I do a sh cdp nei from the switch, i can see the AP and Controller listed. When i configure my PC's nic to 10.74.5.5, and plug a cable from my nic to the SP port on the controller i can get on the device via the gui. In there, the only errors/info that show up in the trap are: Link Up: Slot: 0 Port: 7 Controller time base status - Controller is out of sync with the central timebase. I've manually set the time but apparently that's not quite the problem (or at least not the entire problem). When i plug the AP in, i see on the switch console that it grants it power, it sees it connect...but the controller won't see it for some reason. From what i've read you shouldn't have to do anything to the AP as it's managed by the controller...but i'm not sure what setting I'm missing for it to work. The AP light on top is continually cycling green, red, yellow. When I first start it up, it blinks green for 20 or so seconds, then goes to solid green for another 20 seconds or so, then flashes blue, green, red for awhile...but always ends up goinn back to the standard, green, red, yellow. Does anyone see any obvious issues with my setup or have any suggestions as to why i might be having a problem? Thanks for your help!

    Read the article

  • Rack layout for future growth

    - by bleything
    We're getting ready to move to a new colo facility and I'm designing the rack layout. While we have a full rack, we only have 12U worth of hardware right now: 1x 1U switch 7x 1U servers 1x 2U server 1x 2U disk shelf The colo facility requires us to front-mount the switch and use a 1U brush strip, so we'll be using a total of 13U of space. Regarding growth, I'm reasonably sure we'll be adding another 4U in servers, 1-2U of network gear, and 2-4U of storage in the mid-term. Specific questions I'm hoping to get help with: where should I mount the switch? the LEDs are on top... should I group the servers by function with space for adding new machines? as an alternative, should I group servers based on whether they are production or staging? where in the rack should I start? in the middle? at the top? at the bottom? equally spaced? Here's a silly little ASCII diagram of what I'm thinking right now. Please feel free to tear my design apart, I've really no idea what I'm doing :) Any advice is very welcome. edit: to be clear, the colo is providing redundant power with UPS and generator, so that's why there's no power gear in the plan, except for the 0U PDU that I didn't diagram. 42 | -- switch ---------------------- 41 | -- brush strip ----------------- 40 | ~~ reserved for second switch ~~ 39 | ~~ reserved for firewall ~~~~~~~ 38 | 37 | -- admin01 --------------------- 36 | 35 | -- vm01 ------------------------ 34 | -- vm02 ------------------------ 33 | ~~ reserved for vm03 ~~~~~~~~~~~ 32 | ~~ reserved for vm04 ~~~~~~~~~~~ 31 | ~~ reserved for vm05 ~~~~~~~~~~~ 30 | 29 | -- web01 ----------------------- 28 | -- web02 ----------------------- 27 | ~~ reserved for web03 ~~~~~~~~~~ 26 | ~~ reserved for web04 ~~~~~~~~~~ 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | -- db01 ------------------------ 15 | +- disks ----------------------+ 14 | +------------------------------+ 13 | ~~ reserved for more ~~~~~~~~~~~ 12 | ~~ db01 disks ~~~~~~~~~~~~~~~~~~ 11 | 10 | +- db02 -----------------------+ 9 | +------------------------------+ 8 | ~~ reserved for db02 ~~~~~~~~~~~ 7 | ~~ disks ~~~~~~~~~~~~~~~~~~~~~~~ 6 | ~~ reserved for more ~~~~~~~~~~~ 5 | ~~ db02 disks ~~~~~~~~~~~~~~~~~~ 4 | 3 | 2 | 1 |

    Read the article

  • Unhappy with performance of GBit Ethernet to Fiber converter

    - by Aaron Digulla
    I just bought a TP-Link MC200CM GBit Ethernet (1000-T) to Fiber (1000-SX) media converter. The device works but I'm unhappy with the performance: When connecting my computer over 1000-T (twisted pair, Cat 6, 18meters) with my server, I get a throughput of about 610MBit/s. If I replace the cable with two media converters, I'm left with about 310-315MBit/s (i.e. half the performance). My setup is like this: Computer <- GBit switch <- long cable <- GBit switch <- server Computer <- GBit switch <- MC200CM <- 30m fiber <- MC200CM <- GBit switch <- server Is there a way to improve the performance? Will another MC be faster? Or is that about as much as I can expect with the additional 2 converters?

    Read the article

  • Optical multicast

    - by Randomblue
    I have a 10G XPF+ optical cable with market updates from a stock exchange. This cable goes into a switch, which then multicasts every packet to a couple of computers. The problem with using a switch for multicast is that there is latency overhead, even with a pass-through switch (~200ns). Are there "optical" solutions (I'm thinking of a beam splitter of some sort) which would allow for close to zero latency 10G multicast?

    Read the article

  • send key combination via local network to other mac

    - by choise
    Hi, after a other mac or macbook is connected with a mini display port to a new generation imac you can switch between the imac and the other connected mac pressing cmd+F2(brightness up) using the keyboard of the imac. i connect my macbook to my imac, switch to the macbook and connect the bluetooth keyboard and mouse of my imac to my macbook. after that i'm not able to switch back to my imac, because the keyboard is used on my macbook. i have a second mouse connected to my imac, so i'd would be cool to switch views and control my imac with my second mouse. is it possible to send the shortcut cmd+F2 to my imac from my macbook? via command line or something? using apple script? all ideas are welcome, thanks!

    Read the article

  • Basic multicast network performance problems

    - by davedavedave
    I've been using mpong from 29west's mtools package to get some basic idea of multicast latency across various Cisco switches: 1Gb 2960G, 10Gb 4900M and 10Gb Nexus N5548P. The 1Gb is just for comparison. I have the following results for ~400 runs of mpong on each switch (sending 65536 "ping"-like messages to a receiver which then sends back -- all over multicast). Numbers are latencies measured in microseconds. Switch Average StdDev Min Max 2960 (1Gb) 109.68463 0.092816 109.4328 109.9464 4900M (10Gb) 705.52359 1.607976 703.7693 722.1514 NX 5548(10Gb) 58.563774 0.328242 57.77603 59.32207 The result for 4900M is very surprising. I've tried unicast ping and I see the 4900 has ~10us higher latency than the N5548P (average 73us vs 64us). Iperf (with no attempt to tune it) shows both 10Gb switches give me 9.4Gbps line speed. The two machines are connected to the same switch and we're not doing any multicast routing. OS is RHEL 6. 10Gb NICs are HP 10GbE PCI-E G2 Dual-port NICs (I believe they are rebranded Mellanox cards). The 4900 switch is used in a project with tight access control so I'm waiting for approval before I can access it and check the config. The other two I have full access to configure. I've looked at the Cisco document[2] detailing differences between NX-OS and IOS w.r.t multicast so I've got some ideas to try out but this isn't an area where I have much expertise. Does anyone have any idea what I should be looking at once I get access to the switch? [1] http://docwiki.cisco.com/wiki/Cisco_NX-OS/IOS_Multicast_Comparison

    Read the article

  • wire colors: color vs black vs white (positive vs negative voltage)

    - by David Oneill
    I'm working on building a computer (first time for me). There are several plugs that I need to connect to the motherboard (Power LED, reset switch, etc). Of the two wires, they are either: Color and white (reset switch, power LED, HDD LED) red and black (speaker, power switch) The manual for the motherboard has a nice diagram of where to plug them in, but has them labeled + or -. Which colors are positive, and which are negative?

    Read the article

  • Unable to install mod_wsgi on CentOS 5.5 VPS...

    - by jasonaburton
    I am trying to install mod_wsgi on my VPS, but it won't work. This is what I am doing: wget http://modwsgi.googlecode.com/files/mod_wsgi-2.5.tar.gz tar xzvf mod_wsgi-2.5.tar.gz cd mod_wsgi-2.5 ./configure --with-python=/opt/python2.5/bin/python After I run the above command, I get this error: checking for apxs2... no checking for apxs... no checking Apache version... ./configure: line 1298: apxs: command not found ./configure: line 1298: apxs: command not found ./configure: line 1299: /: is a directory ./configure: line 1461: apxs: command not found configure: creating ./config.status config.status: creating Makefile config.status: error: cannot find input file: Makefile.in Through some research I've discovered that I need to modify my command: ./configure --with-apxs=/usr/local/apache/bin/apxs \ --with-python=/usr/local/bin/python But, /usr/local/apache/ doesn't exist, or so that's what it is telling me. If it doesn't exist, how do I create it with all the files needed, or if apache is located elsewhere on my VPS where would it be located? I'd also like to mention that I ran a command to install apache before this entire deal: yum install httpd so I assumed that was all I needed but apparently not (I am very new at all this server administration stuff so please be gentle) EDIT: This is the tutorial that I have been using to get this all set up: http://binarysushi.com/blog/2009/aug/19/CentOS-5-3-python-2-5-virtualevn-mod-wsgi-and-mod-rpaf/ I got stuck at the heading "Installing mod_wsgi" Thanks for any help!

    Read the article

  • 2 HP Procurve 4000M switches and Comcast SMC Gateway

    - by Cole Tierney
    We've got 2 HP Procurve 4000M switches joined by a trunk. Switch 1 is connected to a Cisco 2600 router which is connected to a T1. Internet traffic for hosts on switch 2 must pass through the trunk to switch 1. We're now switching to Comcast who's given us 4 port SMC router. I would like to connect each switch to the comcast router to reduce traffic on the trunk, but I don't want to create a loop. The switches support spanning tree protocol, but I don't know how this would work with the comcast router. Would a triangle network like this work? Thanks for any tips.

    Read the article

  • How do ring and bus network connect to router?

    - by lantopology
    Sorry this is probably a very silly question, but for some reason i am confused. How does a LAN with bus or ring topology connect to a router and other LANs? For example in a star network they all connect to a switch which can then connect to a router, but where does a switch go and fit in a bus or ring topology? In this image of a ring network there is no switch: http://www.brainbell.com/tutorials/Networking/images/01fig04.gif would the switch in the ring network simply be placed alongside the other nodes? Thank you very much

    Read the article

  • Mount "locked" SD card as read-write in GNU/Linux

    - by Vi
    My Canon PowerShot A470 + CHDK can write to SD-cards that are "locked" (the lock switch is used to make the card bootable), but GNU/Linux `/dev/mmcblk1': Read-only file system (I'm using "Texas Instrument 5-in-1 Multimedia Card Reader") So I have to switch that switch on and off again and again. ("unlocked" to write to the card in Linux, "locked" to boot the camera from it). How to force locked card to be writable in GNU/Linux?

    Read the article

  • Windows XP over two monitors, but one of them switches off at boot... how to fix? How to switch bac

    - by jae
    When booting into XP (x64, Athlon II X2 245, 4GB RAM), my main monitor (got two 19" TFTs hooked up, two gfx cards, a 4650 (1GB, the primary monitor's on this) and a 4350 (512MB)) switches off. Logging in blind (cursor down key, typing password) gets me one screen, the secondary. Booted correctly until about two days ago. No clue what's the cause, last change was (if I don't overlook something) installing the ATI 9-12 hotfix. And booting into Windows 7, after returning from 7, it was like this. For some weird reason, I cannot start Catalyst Control Center (I right-click desktop, choose the CCC entry, the pointer changes to hourglass for a half-second... and nothing. Likewise with "Properties"... I think, as all windows open on the primary (off) screen, and no entry appears in the task bar for Properties) Completely stumped. Windows 7, same setup, works w/o a hitch. The primary monitor appears to run in some unknown, but pretty low, resolution, as the mouse pointer only moves onto it at about half-height. But, w/o CCC or display properties, I cannot check. And, obviously, not change anything. Hope this was not too long-winded. And I'm sure I still forgot essential stuff. :P

    Read the article

  • ProFTPD / PAM issues with new centos/virtualmin install

    - by iamthewit
    Hi All, I just installed CentOS 5.4 on a rackspace cloud server and installed virtualmin which all seemed to go fine. The only problem I have is that I can not access the virtual servers directories via FTP. I get the following from filezilla: Status: Connecting to 1.1.1.1:21... Status: Connection established, waiting for welcome message... Response: 220 FTP Server ready. Command: USER username Response: 331 Password required for username. Command: PASS ******* Response: 230 User username logged in. Status: Connected Status: Retrieving directory listing... Command: PWD Response: 257 "/" is current directory. Command: TYPE I Response: 200 Type set to I Command: PASV Response: 227 Entering Passive Mode (1,1,1,1,216,214) Command: LIST Error: Connection timed out Error: Failed to retrieve directory listing and I get this from my /var/secure/log file Sep 22 19:40:42 stickeeserver proftpd: pam_unix(proftpd:session): session opened for user username by (uid=0) Sep 22 19:40:42 server proftpd[14051]: 94.136.40.82 (::ffff:217.207.31.60[::ffff:217.207.31.60]) - USER nastypasty: Login successful. Sep 22 19:40:42 server proftpd[14051]: 94.136.40.82 (::ffff:217.207.31.60[::ffff:217.207.31.60]) - Preparing to chroot to directory '/home/username' Sep 22 19:40:42 server proftpd[14051]: 94.136.40.82 (::ffff:217.207.31.60[::ffff:217.207.31.60]) - mod_delay/0.5: delaying for 728 usecs Sep 22 19:40:42 server proftpd[14051]: 94.136.40.82 (::ffff:217.207.31.60[::ffff:217.207.31.60]) - error setting IPV6_V6ONLY: Protocol not available Any help would be greatly appreciated, I'm not totally new to Linux but it's not my strongest subject. I do like to know exactly why problems occur though and how exactly to fix them so the more detail the better! cheers

    Read the article

  • iSCSI - what's faster?

    - by Unplugme71
    I have a DroboPro that is currently connected to a GS748TS switch. Also connected to the switch is a server and few workstations. Which method would be better in performance? Add a NIC to the server. Direct connect the DroboPro via iSCSI to the new NIC. Add a NIC to the server. Create a dedicated VLAN for the new NIC and Drobo. Add a NIC to the server and attach it to a separate switch. DroboPro connects to the switch. Becomes a private network, similar to a VLAN. DroboPro has a single ethernet connection. Server has a single ethernet connection (currently). Workstations each have a single ethernet connection.

    Read the article

  • Why is my mono/XSP site loading slow?

    - by acidzombie24
    I have two sites on the same server. One is loading perfectly and incredibly fast. The other is an equally complex site except a bit less javascript and 0 images. Its taking several seconds to load and there is a 1 in 3 chance that i get a Http500 error. WTF I grabbed the lastest 2.6.? version of mono, mod_mono and xsp (libgdiplus-2.6.7, xsp-2.6.5, mod_mono-2.6.3 and mono 2.6.7) This is whats in apache error.log [Mon Jan 03 19:33:40 2011] [error] (70014)End of file found: read_data failed [Mon Jan 03 19:33:40 2011] [error] Command stream corrupted, last command was 1 [Mon Jan 03 19:34:52 2011] [error] (70014)End of file found: read_data failed [Mon Jan 03 19:34:52 2011] [error] (70014)End of file found: read_data failed [Mon Jan 03 19:34:52 2011] [error] Command stream corrupted, last command was 1 [Mon Jan 03 19:34:52 2011] [error] Command stream corrupted, last command was 1 this is the page error Internal Server Error The server encountered an internal error or misconfiguration and was unable to complete your request. Please contact the server administrator, webmaster@localhost and inform them of the time the error occurred, and anything you might have done that may have caused the error. More information about this error may be available in the server error log. Apache/2.2.9 (Debian) PHP/5.2.6-1+lenny9 with Suhosin-Patch mod_mono/2.6.3 Server

    Read the article

  • What is the best desktop KVM?

    - by Mat
    What is the best KVM for a programmer? I need to switch between a locked-down corporate box and my development machine rather than between servers. I've used a Black Box four port PS/2 VGA KVM switch for many years, but with the advent of USB-only PCs and DVI I need to upgrade as it doesn't play well with USB to PS/2 converters. My ideal features: USB keyboard and mouse input/output dual monitor switching four ports, but two would do at a push switch on middle mouse click, or from a keyboard hotkey at a pinch

    Read the article

  • Graciously shutdown external HDD enclosure?

    - by Jakobud
    I recently purchased a large HDD along with the following HDD enclosure: http://www.newegg.com/Product/Product.aspx?Item=N82E16817173043 It has a simple on-off switch on the back. When I want to turn this thing off, do I simply just flip the switch? I assume the switch simply kills the power to the HDD, but isn't that potentially a bad thing in the case that the HDD is still reading/writing? I used to have a Seagate external HDD and it had a button on the front that I had to hold down for a second or two before it would turn off, but it at least appeared to sort of go through a shutdown procedure where it probably would stop the HDD activity before cutting power. So with this external HDD, I'm a little bit leery about that power switch and understanding exactly what it does. Is this how all HDD enclosures are? EDIT: I'm running the drive in Ubuntu Server. So there is no 'ejecting' the drive lol

    Read the article

  • Isolate clients on same subnet?

    - by stefan.at.wpf
    Given n (e.g. 200) clients in a /24 subnet and the following network structure: client 1 \ . \ . switch -- firewall . / client n / (in words: all clients connected to one switch and the switch connected to the firewall) Now by default, e.g. client 1 and client n can communicate directly using the switch, without any packets ever arriving the firewall. Therefore none of those packets could be filtered. However I would like to filter the packets between the clients, therefore I want to disallow any direct communication between the clients. I know this is possible using vlans, but then - according to my understanding - I would have to put all clients in their own network. However I don't even have that much IP addresses: I have about 200 clients, only a /24 subnet and all clients shall have public ip addresses, therefore I can't just create a private network for each of them (well, maybe using some NAT, but I'd like to avoid that). So, is there any way to tell the switch: Forward all packets to the firewall, don't allow direct communication between clients? Thanks for any hint!

    Read the article

  • How can I prepopulate an AutoHotkey InputBox prompt?

    - by Ryan
    I'm running AutoHotkey 1.0.48.05 on Windows 7. I have this script: ::sw:: InputBox, providedString, SVN Switch, Switch the current directory to where? if NOT ErrorLevel { Send svn switch %providedString%{Enter} } Return So I if type sw{Enter} in PowerShell (or anywhere), I'll be prompted by a text box. Currently that text box is blank. How can I prepopulate it with a particular string?

    Read the article

  • Daylight Savings Time and Microsoft Exchange woes

    - by Scott
    Ever since the switch from Standard Time to Daylight Time, the time on our e-mail messages has been ahead by one hour. This symptom has me wondering if the cause is improper configuration of daylight savings settings. Since we're in a client/server environment, the clients synchronize with the server, and the server synchronizes with Boulder, Colorado. If I set both the server and the clients to automatically switch to daylight savings, the clients seem to regard the server as being set to Standard Time and set themselves an hour ahead of it, which is really two hours ahead. Should the server switch to daylight savings and the clients follow along on their next synchronization, or should the server stay on Standard Time and the clients switch over? The system clock on the Exchange Server is currently displaying the correct time. How do I get the e-mail messages to display the correct time in Outlook?

    Read the article

  • Cable management between multiple racks

    - by RippieUK
    I am in the planning phase of re-cabling our 5 racks in one of our offices and I would like to ask for some guidance on how you go, or would go about managing cables that goes between racks. In our situation we have 5 racks where the furthest to the right is our main patch panel for 300 floor ports. The rack next to it is our main comms rack where main switches and ISP routers are located. the other 3 racks next to the comms rack then all need to connect back to the main comms rack. I am not sure if a 48 port patch panel in each rack would be any good for this scenario? mainly because i am not sure this can be linked back to the main switch with only 1 cable. Would a 48 port switch in each rack be better as you can uplink those back to main switch? Or should we just run cables between racks back to the main switch? Hope someone can offer some guidiance. Thx

    Read the article

  • Error when installing wubi on windows 7

    - by P'sao
    Im installing ubuntu on windows 7(wubi 11.10): when its nearly done it gives me this error in the log file: Usage: /cygdrive/c/Users/Psao/AppData/Local/Temp/pyl10D2.tmp/bin/resize2fs.exe -f C:/ubuntu/disks/root.disk 17744M [-d debug_flags] [-f] [-F] [-p] device [new_size] Traceback (most recent call last): File "\lib\wubi\backends\common\tasklist.py", line 197, in __call__ File "\lib\wubi\backends\win32\backend.py", line 461, in expand_diskimage File "\lib\wubi\backends\common\utils.py", line 66, in run_command Exception: Error executing command >>command=C:\Users\P'sao\AppData\Local\Temp\pyl10D2.tmp\bin\resize2fs.exe -f C:\ubuntu\disks\root.disk 17744M >>retval=1 >>stderr= >>stdout=resize2fs 1.40.6 (09-Feb-2008) Usage: /cygdrive/c/Users/Psao/AppData/Local/Temp/pyl10D2.tmp/bin/resize2fs.exe -f C:/ubuntu/disks/root.disk 17744M [-d debug_flags] [-f] [-F] [-p] device [new_size] 10-25 20:31 DEBUG TaskList: # Cancelling tasklist 10-25 20:31 DEBUG TaskList: # Finished tasklist 10-25 20:31 ERROR root: Error executing command >>command=C:\Users\P'sao\AppData\Local\Temp\pyl10D2.tmp\bin\resize2fs.exe -f C:\ubuntu\disks\root.disk 17744M >>retval=1 >>stderr= >>stdout=resize2fs 1.40.6 (09-Feb-2008) Usage: /cygdrive/c/Users/Psao/AppData/Local/Temp/pyl10D2.tmp/bin/resize2fs.exe -f C:/ubuntu/disks/root.disk 17744M [-d debug_flags] [-f] [-F] [-p] device [new_size] Traceback (most recent call last): File "\lib\wubi\application.py", line 58, in run File "\lib\wubi\application.py", line 132, in select_task File "\lib\wubi\application.py", line 158, in run_installer File "\lib\wubi\backends\common\tasklist.py", line 197, in __call__ File "\lib\wubi\backends\win32\backend.py", line 461, in expand_diskimage File "\lib\wubi\backends\common\utils.py", line 66, in run_command Exception: Error executing command >>command=C:\Users\P'sao\AppData\Local\Temp\pyl10D2.tmp\bin\resize2fs.exe -f C:\ubuntu\disks\root.disk 17744M >>retval=1 >>stderr= >>stdout=resize2fs 1.40.6 (09-Feb-2008) Usage: /cygdrive/c/Users/Psao/AppData/Local/Temp/pyl10D2.tmp/bin/resize2fs.exe -f C:/ubuntu/disks/root.disk 17744M [-d debug_flags] [-f] [-F] [-p] device [new_size] can some one help me?