  • Getting a hardware profile from Fedora 12 after installation

    - by Chris T
    I've installed Fedora 12 on a computer I found in the trash (Bulk garbage day!) and I'm trying to figure out what's under the hood (seems like a stock dell but I'd like to know the details). Is there a way to get a hardware profile on Fedora after it's already installed on the harddrive? I saw an option at install but I skipped over it.

    Read the article

  • best way to go about cost-benefit analysis on hardware

    - by Michael
    I'm looking to build a low-end computational server (my jargon in this field is especially limited so if someone can state that better please change that to meet jargon). I'm basically running computational fluid dynamics programs, large matrix computations and bioinformatics code. What would be the best way to approach cost/benefit analysis on what to put in the system? Perhaps even more general: How does one approach cost/benefit analysis on hardware theoretically (doing the analysis before building the machine)?

    Read the article

  • Toolbox for Computer Hardware

    - by Chuy77
    I have a lot of computer hardware (hard drives, cables, etc.) and I need a better way to organize. Could anyone recommend a toolbox intended for this sort of thing, or some other good method for storage? I have a two drawer wide file that I currently use, with large plastic bags. It works okay, but I need a better system. Thanks for any advice.

    Read the article

  • Rules to choose hardware for OLTP systems (sql server)

    - by Roman Pokrovskij
    Ok. We know database size, number of concurrent users, number of transactions per minute; should choose number of processors, RAID, RAM, mirroring and clustering. There are no exact rule.. but may be there are no rules at all? In my practice in every case I have "legacy" system, and after some inspections and interview I can form an opinion how hardware and design can be improved. But every time when I meet "absolutely" new system (I guess there are no new systems, but sometimes are such tasks) I can't say anything trustful. So I'm interesting how people deal with such tasks? They map task on theirs experience or have some base formulas?

    Read the article

  • FreeBSD after motherboard replacement; should I have any concerns?

    - by cc
    So after three years my motherboard (Asus M2N-0MX) has died off. As I go shopping for i's replacement tomorrow I have a concern about the data that I currently have on the drives wtihin. I'm currently running BSD 6.2, and am wondering if there would be any concern with installing a new OS on that system, would it be better to jsut install the latest BSD version, and are their any pitfalls that I should watch for to make sure I don't end up losing 750gb's of data. The setup consists of the following(to the best of my knowledge): Pioneer DVD drive 3ware RAID card four 250gb SATA drives in RAID 5 config thanks to anyone that can offer some advice, or just to confirm if I am over thinking things.

    Read the article

  • Workstation hardware at does your company buy developers?

    - by Bosh
    I'm curious to know what workstation hardware companies are devoting to you, as a developer -- and how much they're spending. I'd consider this thread a big success if I could shed some light on these questions: Do engineers at big companies use substantially different hardware than engineers at start-ups companies? Does a fresh developer recruit at Google get substantially different hardware from someone in the same position at Microsoft or Yahoo!? Do programmers in more senior positions have more powerful hardware on their desks? Does anyone think faster hardware makes more efficient engineers?

    Read the article

  • Feeding a Dog Remotely - hardware?

    - by RobDude
    I'm looking for a way to, remotely, activate some sort of treat dispenser. I'm not a hardware guy, and I'm sure that conceptually, this is very easy. But I don't know how to begin. I haven't found any products designed to do exactly this. Perhaps some sort of beginning robotics kit could do it?

    Read the article

  • Diagnosing iMac Hardware?

    - by Covar
    Recently my first generation Intel iMac that I've had since 2006 has begun to lock up and restart on me. Before I run off and spend $1500-$2000 on a new iMac, is there any good way to diagnose the hardware? I would like to know exactly what is going wrong so I know I won't be wasting my money when there is an easier fix.

    Read the article

  • Need a hardware solution for remote controling a PC

    - by ShacharWeis
    Hello We have kiosk computers scattered around the country, and are using VNC to control them. But VNC has limitations (only works if the OS is intact, for instance). I want to be able to control the computer even if it is stuck in boot. Is there a cheap hardware solution for remote controlling a PC ? Thanks.

    Read the article

  • Hardware needed for receiving and recording videcalls in Asterisk

    - by jneves
    I'm planning an Asterisk configuration that should record videocalls and then feed it to an application. From what I've researched, it seems like app_h234m is the way to go (http://www.voip-info.org/wiki/view/Asterisk+app_h324m+compatibility). But it's not clear to me what are the hardware requirements for this. Can someone enlighten me?

    Read the article

  • Oracle Linux and Oracle VM Hardware Certification Program

    - by Durgam Vahia
    The Oracle Linux and Oracle VM are continuing to see growth in IHV (Independent Hardware Vendor) ecosystem. The Oracle Linux and Oracle VM Hardware Certification Program, also referred as HCL, provides a formal means for hardware vendors to work with Oracle to establish high quality support for the certified hardware platform. Since the beginning of the program, number of hardware partners have certified range of server platforms on Oracle Linux and Oracle VM. Currently, HCL lists over 400 certifications from 10 server vendors and the list continues to grow at a rapid pace. New hardware certification involves close collaboration between Oracle and server partner to ensure that adequate testing is performed on the target server and results are thoroughly reviewed. This rigorous process ensures that when new hardware platform is listed on HCL, it has full support from both Oracle and the respective partner. Additionally, once a certification is achieved with Oracle Linux with the current version of Unbreakable Enterprise Kernel, future minor updates of the software continue to carry over the certification, reducing the need for a re-certification. For the complete list of certified hardware, please visit Oracle Linux and Oracle VM Certified Hardware. Also refer to Frequently Asked Questions for more information.

    Read the article

  • Slow disk transfer rate

    - by Nooklez
    I have problem with slow disk transfer rate. It's static files server for our website. I was making backup of data and noticed that tar is very slow. So I did hdparm -t and... hdparm -t /dev/sda3 /dev/sda3: Timing buffered disk reads: 6 MB in 4.70 seconds = 1.28 MB/sec It's low traffic hour now on our site, so huge I/O traffic is not a reason (iotop show less than 1 MB/s). It's RAID10 setup (2x2 SATA drives). Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy ------------------------------------------------------------------------------ u0 RAID-10 OK - - 64K 1396.96 W ON VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 698.63 GB SATA 0 - WDC WD7500AADS-00M2 p1 OK u0 698.63 GB SATA 1 - WDC WD7500AADS-00M2 p2 OK u0 698.63 GB SATA 2 - WDC WD7500AADS-00M2 p3 OK u0 698.63 GB SATA 3 - WDC WD7500AADS-00M2 We have recently changed almost all components of server (excluding 3ware controller + disks). And I think problems started since then. Can it be configuration problem or hardware? EDIT: I found something like that in dmesg [166843.625843] irq 16: nobody cared (try booting with the "irqpoll" option) [166843.625846] Pid: 0, comm: swapper Not tainted 3.1.5-gentoo #3 [166843.625847] Call Trace: [166843.625848] <IRQ> [<ffffffff810859d5>] __report_bad_irq+0x35/0xc1 [166843.625856] [<ffffffff81085cec>] note_interrupt+0x165/0x1e1 [166843.625859] [<ffffffff8108445f>] handle_irq_event_percpu+0x16f/0x187 [166843.625861] [<ffffffff810844a9>] handle_irq_event+0x32/0x51 [166843.625863] [<ffffffff8108640b>] handle_fasteoi_irq+0x75/0x99 [166843.625866] [<ffffffff810039d7>] handle_irq+0x83/0x8b [166843.625868] [<ffffffff810036ad>] do_IRQ+0x48/0xa0 [166843.625871] [<ffffffff8155082b>] common_interrupt+0x6b/0x6b [166843.625872] <EOI> [<ffffffff812981e8>] ? acpi_safe_halt+0x22/0x35 [166843.625877] [<ffffffff812981e2>] ? acpi_safe_halt+0x1c/0x35 [166843.625879] [<ffffffff81298216>] acpi_idle_do_entry+0x1b/0x2b [166843.625881] [<ffffffff81298276>] acpi_idle_enter_c1+0x50/0x99 [166843.625884] [<ffffffff813b792a>] cpuidle_idle_call+0xed/0x171 [166843.625886] [<ffffffff81001257>] cpu_idle+0x55/0x81 [166843.625888] [<ffffffff81532a69>] rest_init+0x6d/0x6f [166843.625891] [<ffffffff81aa1aca>] start_kernel+0x329/0x334 [166843.625893] [<ffffffff81aa12a6>] x86_64_start_reservations+0xb6/0xba [166843.625894] [<ffffffff81aa139c>] x86_64_start_kernel+0xf2/0xf9 [166843.625896] handlers: [166843.625898] [<ffffffff812dc8de>] twl_interrupt [166843.625900] Disabling IRQ #16 It's related to problem? EDIT #2: Based on feedback in comments, here is more informations. cat /proc/interrupts 16: 390813 0 0 0 IO-APIC-fasteoi 3w-sas Controller model: [ 1.095350] 3ware Storage Controller device driver for Linux v1.26.02.003. [ 1.095467] 3ware 9000 Storage Controller device driver for Linux v2.26.02.014. [ 1.095641] LSI 3ware SAS/SATA-RAID Controller device driver for Linux v3.26.02.000. [ 1.095787] 3w-sas 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 1.095881] 3w-sas 0000:01:00.0: setting latency timer to 64 [ 1.910801] 3w-sas: scsi0: Found an LSI 3ware 9750-4i Controller at 0xfe560000, IRQ: 16. [ 2.216537] 3w-sas: scsi0: Firmware FH9X 5.08.00.008, BIOS BE9X 5.07.00.011, Phys: 8. [ 2.216836] scsi 0:0:0:0: Direct-Access LSI 9750-4i DISK 5.08 PQ: 0 ANSI: 5 And motherboard: description: Motherboard product: P8H67-M vendor: ASUSTeK Computer INC.

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • Linux (or Anaconda) installation, RAID 5

    - by user48058
    I having trouble with installation of Fedora and/or Centos. On first steps of installation, on step What type of devices will your installation involve, whatever I choose, same thing happen: I get window with message An unhandled exception has occurred. This is most likely a bug. Please save a copy of the detailed exception and file a bug report. In Details window there are lots of messages. At the end there are: ERR kernel:[ 81.854179] device-mapper: table: 253:1: raid45: unknown target type WARNING kernel:[ 81.854183] device-mapper: ioctl: error adding target to table Same thing occur with several versions of Fedora (17 and 16, x64, live, etc) and with Centos distribution also. Can you please give me some advices how to avoid this messages? Thank you in advance!

    Read the article

  • Linux software raid robustness

    - by Waxhead
    I have a 4 disk 5TB raid5 setup where a disk is showing signs of going down the drain. It is reporting media errors and from dmesg I can see that several read errors are corrected. smartctl does report "notifications" but no panic so far. Since new disks are rather expensive at the moment I am starting to pondering exactly how robust the linux md layer is. I would appreciate if someone could shed some light on how md actually deals with disk errors. For example how does md deal with write and read errors - what does it (really) take for disk to be rejected from an array. I also read that recently md got support for mapping out bad blocks. Does this mean that the read errors I've had would have been mapped out if I where running kernel 3.1 or would md still try to "work on them" to make them usable.

    Read the article

  • CPU Usage at 100% with "Hardware Interrupts"

    - by eventualEntropy
    After turning on my desktop one day, I found that my CPU usage was maxed out at 100%, with 99% of that going to hardware "Interrupts". I tried to enable/disable all my devices one by one through the device manager, and found that I could get the CPU usage used by the Interrupts down to 50% by disabling all devices labelled "USB Host Controller" (except the ones for the mouse/keyboard). I found that I also got 10-20% more from disabling "High Definition Audio Controller". Following the tutorial at: http://www.msfn.org/board/topic/140263-how-to-get-the-cause-of-high-cpu-usage-by-dpc-interrupt/ Led me to similar conclusions (that is, that the culprit is mostly "USB Host Controller"): I've tried updating my asus motherboard driver and my video card driver. This is on Windows 7 64 bit. I've spent hours trying to figure this out and I'm running out of ideas short of formatting (which might still not fix it!).

    Read the article

  • How to remove raid 5 array of 5 SAS and use only use one SAS at a time without writing any thing to disc for recovery

    - by murtaza hamid
    I have HP server ML370 g5 with 8 SAS, c drive 1 72 gb raid 0, d drive 2 72 gb raid 0, f drive 5 146 gb raid 5. 2 of 5 sas drive has got bad sectors and raid 5 is showing status failed. now i want to remove all this 5 SAS and put 1 by 1 in any of the bay to make its image for data recovery purpose without writing anything to the drive. how should i proceed. i also want to keep drive c and d intact. also is it possible if i put all this 5 drives in the bay with the same sequense will it recognise the raid 5 array ( i read some where its smart controller..just curious) many thanks in advance.

    Read the article

  • Replacement Alternative for Dell FY606 in a Poweredge T105

    - by Mike C
    I have recently upgraded my Poweredge T105 server to use a SAS 6/ir RAID controller. Unfortunately, I did not realize at the time that adding the card would cause the BIOS to complain about a missing hard drive fan. This warning requires that a user press F1 to continue, which is disastrous in a server environment. I have searched all over found that the specific part I need is a Dell FY606 fan. However, I have yet to find a suitable retailer that covers this part. I have contacted Dell and they do not have this part in stock. Are there any alternative models of a fan that I could use in place of an FY606? Seems like a pretty straightforward part, just a fan that connects to a 4-pin power connector on the motherboard.

    Read the article

  • Virtual server hardware to simulate 3-4 node web farm

    - by frankadelic
    I would like to get a dedicated server to run VMWare, VirtualBox, or similar. On this box, I would like to host 3-4 virtual instances of Linux, to act as nodes in a web farm. Performance is not that important, this would only be for testing and experimenting. I need something sub $1000 (including tax/shipping). Can someone recommend a pre-built server that would do the trick? I am pretty ignorant of hardware so building one is not going to work for me. Also, would I need multiple network cards to simulate a web farm or can the virtualization software handle that for me. Thanks

    Read the article

  • Raid 11 : how to stop @ how to release devices

    - by santhosha
    #cat /proc/mdstat md7 : active raid10 sdh1[2] 286743936 blocks 64K chunks 2 near-copies [4/1] [__U_] [0:0:3:0] #mdadm -f /dev/md7 /dev/sdh1 mdadm: set /dev/sdh1 faulty in /dev/md7 #mdadm -r /dev/md7 /dev/sdh1 mdadm: hot remove failed for /dev/sdh1: Device or resource busy # umount /dev/md7 umount: /dev/md7: not mounted #mdadm --stop /dev/md7 mdadm: fail to stop array /dev/md7: Device or resource busy #cat /proc/mdstat md7 : active raid10 sdh1[2] 286743936 blocks 64K chunks 2 near-copies [4/1] [__U_] [0:0:3:0]

    Read the article

  • Raid HDD Boot up

    - by user234695
    My server is Power Edge 1950 running server 2008 32Bit, using 3 Physical SAS HDD as a Virtual 2 Disk configured for RAID5, with partition of C drive as OS and D drive as Data. Planning to format and install Server 2008 R2 64Bit so I insert a New Physical disk and configured as RAID5 and clone the C drive and D drive to the new hard disk. Now I need to test that the new hard disk is able to boot windows and work as expected. How do I test, I am not able to boot the windows by choosing the new harddisk, the bios show only the existing HDD, not the new one. Also, if I remove the old three hard disk, and leave the new harddisk and then am I able to boot the device, if I do this does my existing RAID5 configuration and data on the hard disk still remain.

    Read the article

< Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >