Search Results

Search found 43978 results on 1760 pages for 'select case'.

Page 241/1760 | < Previous Page | 237 238 239 240 241 242 243 244 245 246 247 248  | Next Page >

  • Understanding G1 GC Logs

    - by poonam
    The purpose of this post is to explain the meaning of GC logs generated with some tracing and diagnostic options for G1 GC. We will take a look at the output generated with PrintGCDetails which is a product flag and provides the most detailed level of information. Along with that, we will also look at the output of two diagnostic flags that get enabled with -XX:+UnlockDiagnosticVMOptions option - G1PrintRegionLivenessInfo that prints the occupancy and the amount of space used by live objects in each region at the end of the marking cycle and G1PrintHeapRegions that provides detailed information on the heap regions being allocated and reclaimed. We will be looking at the logs generated with JDK 1.7.0_04 using these options. Option -XX:+PrintGCDetails Here's a sample log of G1 collection generated with PrintGCDetails. 0.522: [GC pause (young), 0.15877971 secs] [Parallel Time: 157.1 ms] [GC Worker Start (ms): 522.1 522.2 522.2 522.2 Avg: 522.2, Min: 522.1, Max: 522.2, Diff: 0.1] [Ext Root Scanning (ms): 1.6 1.5 1.6 1.9 Avg: 1.7, Min: 1.5, Max: 1.9, Diff: 0.4] [Update RS (ms): 38.7 38.8 50.6 37.3 Avg: 41.3, Min: 37.3, Max: 50.6, Diff: 13.3] [Processed Buffers : 2 2 3 2 Sum: 9, Avg: 2, Min: 2, Max: 3, Diff: 1] [Scan RS (ms): 9.9 9.7 0.0 9.7 Avg: 7.3, Min: 0.0, Max: 9.9, Diff: 9.9] [Object Copy (ms): 106.7 106.8 104.6 107.9 Avg: 106.5, Min: 104.6, Max: 107.9, Diff: 3.3] [Termination (ms): 0.0 0.0 0.0 0.0 Avg: 0.0, Min: 0.0, Max: 0.0, Diff: 0.0] [Termination Attempts : 1 4 4 6 Sum: 15, Avg: 3, Min: 1, Max: 6, Diff: 5] [GC Worker End (ms): 679.1 679.1 679.1 679.1 Avg: 679.1, Min: 679.1, Max: 679.1, Diff: 0.1] [GC Worker (ms): 156.9 157.0 156.9 156.9 Avg: 156.9, Min: 156.9, Max: 157.0, Diff: 0.1] [GC Worker Other (ms): 0.3 0.3 0.3 0.3 Avg: 0.3, Min: 0.3, Max: 0.3, Diff: 0.0] [Clear CT: 0.1 ms] [Other: 1.5 ms] [Choose CSet: 0.0 ms] [Ref Proc: 0.3 ms] [Ref Enq: 0.0 ms] [Free CSet: 0.3 ms] [Eden: 12M(12M)->0B(10M) Survivors: 0B->2048K Heap: 13M(64M)->9739K(64M)] [Times: user=0.59 sys=0.02, real=0.16 secs] This is the typical log of an Evacuation Pause (G1 collection) in which live objects are copied from one set of regions (young OR young+old) to another set. It is a stop-the-world activity and all the application threads are stopped at a safepoint during this time. This pause is made up of several sub-tasks indicated by the indentation in the log entries. Here's is the top most line that gets printed for the Evacuation Pause. 0.522: [GC pause (young), 0.15877971 secs] This is the highest level information telling us that it is an Evacuation Pause that started at 0.522 secs from the start of the process, in which all the regions being evacuated are Young i.e. Eden and Survivor regions. This collection took 0.15877971 secs to finish. Evacuation Pauses can be mixed as well. In which case the set of regions selected include all of the young regions as well as some old regions. 1.730: [GC pause (mixed), 0.32714353 secs] Let's take a look at all the sub-tasks performed in this Evacuation Pause. [Parallel Time: 157.1 ms] Parallel Time is the total elapsed time spent by all the parallel GC worker threads. The following lines correspond to the parallel tasks performed by these worker threads in this total parallel time, which in this case is 157.1 ms. [GC Worker Start (ms): 522.1 522.2 522.2 522.2Avg: 522.2, Min: 522.1, Max: 522.2, Diff: 0.1] The first line tells us the start time of each of the worker thread in milliseconds. The start times are ordered with respect to the worker thread ids – thread 0 started at 522.1ms and thread 1 started at 522.2ms from the start of the process. The second line tells the Avg, Min, Max and Diff of the start times of all of the worker threads. [Ext Root Scanning (ms): 1.6 1.5 1.6 1.9 Avg: 1.7, Min: 1.5, Max: 1.9, Diff: 0.4] This gives us the time spent by each worker thread scanning the roots (globals, registers, thread stacks and VM data structures). Here, thread 0 took 1.6ms to perform the root scanning task and thread 1 took 1.5 ms. The second line clearly shows the Avg, Min, Max and Diff of the times spent by all the worker threads. [Update RS (ms): 38.7 38.8 50.6 37.3 Avg: 41.3, Min: 37.3, Max: 50.6, Diff: 13.3] Update RS gives us the time each thread spent in updating the Remembered Sets. Remembered Sets are the data structures that keep track of the references that point into a heap region. Mutator threads keep changing the object graph and thus the references that point into a particular region. We keep track of these changes in buffers called Update Buffers. The Update RS sub-task processes the update buffers that were not able to be processed concurrently, and updates the corresponding remembered sets of all regions. [Processed Buffers : 2 2 3 2Sum: 9, Avg: 2, Min: 2, Max: 3, Diff: 1] This tells us the number of Update Buffers (mentioned above) processed by each worker thread. [Scan RS (ms): 9.9 9.7 0.0 9.7 Avg: 7.3, Min: 0.0, Max: 9.9, Diff: 9.9] These are the times each worker thread had spent in scanning the Remembered Sets. Remembered Set of a region contains cards that correspond to the references pointing into that region. This phase scans those cards looking for the references pointing into all the regions of the collection set. [Object Copy (ms): 106.7 106.8 104.6 107.9 Avg: 106.5, Min: 104.6, Max: 107.9, Diff: 3.3] These are the times spent by each worker thread copying live objects from the regions in the Collection Set to the other regions. [Termination (ms): 0.0 0.0 0.0 0.0 Avg: 0.0, Min: 0.0, Max: 0.0, Diff: 0.0] Termination time is the time spent by the worker thread offering to terminate. But before terminating, it checks the work queues of other threads and if there are still object references in other work queues, it tries to steal object references, and if it succeeds in stealing a reference, it processes that and offers to terminate again. [Termination Attempts : 1 4 4 6 Sum: 15, Avg: 3, Min: 1, Max: 6, Diff: 5] This gives the number of times each thread has offered to terminate. [GC Worker End (ms): 679.1 679.1 679.1 679.1 Avg: 679.1, Min: 679.1, Max: 679.1, Diff: 0.1] These are the times in milliseconds at which each worker thread stopped. [GC Worker (ms): 156.9 157.0 156.9 156.9 Avg: 156.9, Min: 156.9, Max: 157.0, Diff: 0.1] These are the total lifetimes of each worker thread. [GC Worker Other (ms): 0.3 0.3 0.3 0.3Avg: 0.3, Min: 0.3, Max: 0.3, Diff: 0.0] These are the times that each worker thread spent in performing some other tasks that we have not accounted above for the total Parallel Time. [Clear CT: 0.1 ms] This is the time spent in clearing the Card Table. This task is performed in serial mode. [Other: 1.5 ms] Time spent in the some other tasks listed below. The following sub-tasks (which individually may be parallelized) are performed serially. [Choose CSet: 0.0 ms] Time spent in selecting the regions for the Collection Set. [Ref Proc: 0.3 ms] Total time spent in processing Reference objects. [Ref Enq: 0.0 ms] Time spent in enqueuing references to the ReferenceQueues. [Free CSet: 0.3 ms] Time spent in freeing the collection set data structure. [Eden: 12M(12M)->0B(13M) Survivors: 0B->2048K Heap: 14M(64M)->9739K(64M)] This line gives the details on the heap size changes with the Evacuation Pause. This shows that Eden had the occupancy of 12M and its capacity was also 12M before the collection. After the collection, its occupancy got reduced to 0 since everything is evacuated/promoted from Eden during a collection, and its target size grew to 13M. The new Eden capacity of 13M is not reserved at this point. This value is the target size of the Eden. Regions are added to Eden as the demand is made and when the added regions reach to the target size, we start the next collection. Similarly, Survivors had the occupancy of 0 bytes and it grew to 2048K after the collection. The total heap occupancy and capacity was 14M and 64M receptively before the collection and it became 9739K and 64M after the collection. Apart from the evacuation pauses, G1 also performs concurrent-marking to build the live data information of regions. 1.416: [GC pause (young) (initial-mark), 0.62417980 secs] ….... 2.042: [GC concurrent-root-region-scan-start] 2.067: [GC concurrent-root-region-scan-end, 0.0251507] 2.068: [GC concurrent-mark-start] 3.198: [GC concurrent-mark-reset-for-overflow] 4.053: [GC concurrent-mark-end, 1.9849672 sec] 4.055: [GC remark 4.055: [GC ref-proc, 0.0000254 secs], 0.0030184 secs] [Times: user=0.00 sys=0.00, real=0.00 secs] 4.088: [GC cleanup 117M->106M(138M), 0.0015198 secs] [Times: user=0.00 sys=0.00, real=0.00 secs] 4.090: [GC concurrent-cleanup-start] 4.091: [GC concurrent-cleanup-end, 0.0002721] The first phase of a marking cycle is Initial Marking where all the objects directly reachable from the roots are marked and this phase is piggy-backed on a fully young Evacuation Pause. 2.042: [GC concurrent-root-region-scan-start] This marks the start of a concurrent phase that scans the set of root-regions which are directly reachable from the survivors of the initial marking phase. 2.067: [GC concurrent-root-region-scan-end, 0.0251507] End of the concurrent root region scan phase and it lasted for 0.0251507 seconds. 2.068: [GC concurrent-mark-start] Start of the concurrent marking at 2.068 secs from the start of the process. 3.198: [GC concurrent-mark-reset-for-overflow] This indicates that the global marking stack had became full and there was an overflow of the stack. Concurrent marking detected this overflow and had to reset the data structures to start the marking again. 4.053: [GC concurrent-mark-end, 1.9849672 sec] End of the concurrent marking phase and it lasted for 1.9849672 seconds. 4.055: [GC remark 4.055: [GC ref-proc, 0.0000254 secs], 0.0030184 secs] This corresponds to the remark phase which is a stop-the-world phase. It completes the left over marking work (SATB buffers processing) from the previous phase. In this case, this phase took 0.0030184 secs and out of which 0.0000254 secs were spent on Reference processing. 4.088: [GC cleanup 117M->106M(138M), 0.0015198 secs] Cleanup phase which is again a stop-the-world phase. It goes through the marking information of all the regions, computes the live data information of each region, resets the marking data structures and sorts the regions according to their gc-efficiency. In this example, the total heap size is 138M and after the live data counting it was found that the total live data size dropped down from 117M to 106M. 4.090: [GC concurrent-cleanup-start] This concurrent cleanup phase frees up the regions that were found to be empty (didn't contain any live data) during the previous stop-the-world phase. 4.091: [GC concurrent-cleanup-end, 0.0002721] Concurrent cleanup phase took 0.0002721 secs to free up the empty regions. Option -XX:G1PrintRegionLivenessInfo Now, let's look at the output generated with the flag G1PrintRegionLivenessInfo. This is a diagnostic option and gets enabled with -XX:+UnlockDiagnosticVMOptions. G1PrintRegionLivenessInfo prints the live data information of each region during the Cleanup phase of the concurrent-marking cycle. 26.896: [GC cleanup ### PHASE Post-Marking @ 26.896### HEAP committed: 0x02e00000-0x0fe00000 reserved: 0x02e00000-0x12e00000 region-size: 1048576 Cleanup phase of the concurrent-marking cycle started at 26.896 secs from the start of the process and this live data information is being printed after the marking phase. Committed G1 heap ranges from 0x02e00000 to 0x0fe00000 and the total G1 heap reserved by JVM is from 0x02e00000 to 0x12e00000. Each region in the G1 heap is of size 1048576 bytes. ### type address-range used prev-live next-live gc-eff### (bytes) (bytes) (bytes) (bytes/ms) This is the header of the output that tells us about the type of the region, address-range of the region, used space in the region, live bytes in the region with respect to the previous marking cycle, live bytes in the region with respect to the current marking cycle and the GC efficiency of that region. ### FREE 0x02e00000-0x02f00000 0 0 0 0.0 This is a Free region. ### OLD 0x02f00000-0x03000000 1048576 1038592 1038592 0.0 Old region with address-range from 0x02f00000 to 0x03000000. Total used space in the region is 1048576 bytes, live bytes as per the previous marking cycle are 1038592 and live bytes with respect to the current marking cycle are also 1038592. The GC efficiency has been computed as 0. ### EDEN 0x03400000-0x03500000 20992 20992 20992 0.0 This is an Eden region. ### HUMS 0x0ae00000-0x0af00000 1048576 1048576 1048576 0.0### HUMC 0x0af00000-0x0b000000 1048576 1048576 1048576 0.0### HUMC 0x0b000000-0x0b100000 1048576 1048576 1048576 0.0### HUMC 0x0b100000-0x0b200000 1048576 1048576 1048576 0.0### HUMC 0x0b200000-0x0b300000 1048576 1048576 1048576 0.0### HUMC 0x0b300000-0x0b400000 1048576 1048576 1048576 0.0### HUMC 0x0b400000-0x0b500000 1001480 1001480 1001480 0.0 These are the continuous set of regions called Humongous regions for storing a large object. HUMS (Humongous starts) marks the start of the set of humongous regions and HUMC (Humongous continues) tags the subsequent regions of the humongous regions set. ### SURV 0x09300000-0x09400000 16384 16384 16384 0.0 This is a Survivor region. ### SUMMARY capacity: 208.00 MB used: 150.16 MB / 72.19 % prev-live: 149.78 MB / 72.01 % next-live: 142.82 MB / 68.66 % At the end, a summary is printed listing the capacity, the used space and the change in the liveness after the completion of concurrent marking. In this case, G1 heap capacity is 208MB, total used space is 150.16MB which is 72.19% of the total heap size, live data in the previous marking was 149.78MB which was 72.01% of the total heap size and the live data as per the current marking is 142.82MB which is 68.66% of the total heap size. Option -XX:+G1PrintHeapRegions G1PrintHeapRegions option logs the regions related events when regions are committed, allocated into or are reclaimed. COMMIT/UNCOMMIT events G1HR COMMIT [0x6e900000,0x6ea00000]G1HR COMMIT [0x6ea00000,0x6eb00000] Here, the heap is being initialized or expanded and the region (with bottom: 0x6eb00000 and end: 0x6ec00000) is being freshly committed. COMMIT events are always generated in order i.e. the next COMMIT event will always be for the uncommitted region with the lowest address. G1HR UNCOMMIT [0x72700000,0x72800000]G1HR UNCOMMIT [0x72600000,0x72700000] Opposite to COMMIT. The heap got shrunk at the end of a Full GC and the regions are being uncommitted. Like COMMIT, UNCOMMIT events are also generated in order i.e. the next UNCOMMIT event will always be for the committed region with the highest address. GC Cycle events G1HR #StartGC 7G1HR CSET 0x6e900000G1HR REUSE 0x70500000G1HR ALLOC(Old) 0x6f800000G1HR RETIRE 0x6f800000 0x6f821b20G1HR #EndGC 7 This shows start and end of an Evacuation pause. This event is followed by a GC counter tracking both evacuation pauses and Full GCs. Here, this is the 7th GC since the start of the process. G1HR #StartFullGC 17G1HR UNCOMMIT [0x6ed00000,0x6ee00000]G1HR POST-COMPACTION(Old) 0x6e800000 0x6e854f58G1HR #EndFullGC 17 Shows start and end of a Full GC. This event is also followed by the same GC counter as above. This is the 17th GC since the start of the process. ALLOC events G1HR ALLOC(Eden) 0x6e800000 The region with bottom 0x6e800000 just started being used for allocation. In this case it is an Eden region and allocated into by a mutator thread. G1HR ALLOC(StartsH) 0x6ec00000 0x6ed00000G1HR ALLOC(ContinuesH) 0x6ed00000 0x6e000000 Regions being used for the allocation of Humongous object. The object spans over two regions. G1HR ALLOC(SingleH) 0x6f900000 0x6f9eb010 Single region being used for the allocation of Humongous object. G1HR COMMIT [0x6ee00000,0x6ef00000]G1HR COMMIT [0x6ef00000,0x6f000000]G1HR COMMIT [0x6f000000,0x6f100000]G1HR COMMIT [0x6f100000,0x6f200000]G1HR ALLOC(StartsH) 0x6ee00000 0x6ef00000G1HR ALLOC(ContinuesH) 0x6ef00000 0x6f000000G1HR ALLOC(ContinuesH) 0x6f000000 0x6f100000G1HR ALLOC(ContinuesH) 0x6f100000 0x6f102010 Here, Humongous object allocation request could not be satisfied by the free committed regions that existed in the heap, so the heap needed to be expanded. Thus new regions are committed and then allocated into for the Humongous object. G1HR ALLOC(Old) 0x6f800000 Old region started being used for allocation during GC. G1HR ALLOC(Survivor) 0x6fa00000 Region being used for copying old objects into during a GC. Note that Eden and Humongous ALLOC events are generated outside the GC boundaries and Old and Survivor ALLOC events are generated inside the GC boundaries. Other Events G1HR RETIRE 0x6e800000 0x6e87bd98 Retire and stop using the region having bottom 0x6e800000 and top 0x6e87bd98 for allocation. Note that most regions are full when they are retired and we omit those events to reduce the output volume. A region is retired when another region of the same type is allocated or we reach the start or end of a GC(depending on the region). So for Eden regions: For example: 1. ALLOC(Eden) Foo2. ALLOC(Eden) Bar3. StartGC At point 2, Foo has just been retired and it was full. At point 3, Bar was retired and it was full. If they were not full when they were retired, we will have a RETIRE event: 1. ALLOC(Eden) Foo2. RETIRE Foo top3. ALLOC(Eden) Bar4. StartGC G1HR CSET 0x6e900000 Region (bottom: 0x6e900000) is selected for the Collection Set. The region might have been selected for the collection set earlier (i.e. when it was allocated). However, we generate the CSET events for all regions in the CSet at the start of a GC to make sure there's no confusion about which regions are part of the CSet. G1HR POST-COMPACTION(Old) 0x6e800000 0x6e839858 POST-COMPACTION event is generated for each non-empty region in the heap after a full compaction. A full compaction moves objects around, so we don't know what the resulting shape of the heap is (which regions were written to, which were emptied, etc.). To deal with this, we generate a POST-COMPACTION event for each non-empty region with its type (old/humongous) and the heap boundaries. At this point we should only have Old and Humongous regions, as we have collapsed the young generation, so we should not have eden and survivors. POST-COMPACTION events are generated within the Full GC boundary. G1HR CLEANUP 0x6f400000G1HR CLEANUP 0x6f300000G1HR CLEANUP 0x6f200000 These regions were found empty after remark phase of Concurrent Marking and are reclaimed shortly afterwards. G1HR #StartGC 5G1HR CSET 0x6f400000G1HR CSET 0x6e900000G1HR REUSE 0x6f800000 At the end of a GC we retire the old region we are allocating into. Given that its not full, we will carry on allocating into it during the next GC. This is what REUSE means. In the above case 0x6f800000 should have been the last region with an ALLOC(Old) event during the previous GC and should have been retired before the end of the previous GC. G1HR ALLOC-FORCE(Eden) 0x6f800000 A specialization of ALLOC which indicates that we have reached the max desired number of the particular region type (in this case: Eden), but we decided to allocate one more. Currently it's only used for Eden regions when we extend the young generation because we cannot do a GC as the GC-Locker is active. G1HR EVAC-FAILURE 0x6f800000 During a GC, we have failed to evacuate an object from the given region as the heap is full and there is no space left to copy the object. This event is generated within GC boundaries and exactly once for each region from which we failed to evacuate objects. When Heap Regions are reclaimed ? It is also worth mentioning when the heap regions in the G1 heap are reclaimed. All regions that are in the CSet (the ones that appear in CSET events) are reclaimed at the end of a GC. The exception to that are regions with EVAC-FAILURE events. All regions with CLEANUP events are reclaimed. After a Full GC some regions get reclaimed (the ones from which we moved the objects out). But that is not shown explicitly, instead the non-empty regions that are left in the heap are printed out with the POST-COMPACTION events.

    Read the article

  • JMS Step 5 - How to Create an 11g BPEL Process Which Reads a Message Based on an XML Schema from a JMS Queue

    - by John-Brown.Evans
    JMS Step 5 - How to Create an 11g BPEL Process Which Reads a Message Based on an XML Schema from a JMS Queue .jblist{list-style-type:disc;margin:0;padding:0;padding-left:0pt;margin-left:36pt} ol{margin:0;padding:0} .c12_5{vertical-align:top;width:468pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c8_5{vertical-align:top;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 0pt 5pt} .c10_5{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c14_5{vertical-align:top;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c21_5{background-color:#ffffff} .c18_5{color:#1155cc;text-decoration:underline} .c16_5{color:#666666;font-size:12pt} .c5_5{background-color:#f3f3f3;font-weight:bold} .c19_5{color:inherit;text-decoration:inherit} .c3_5{height:11pt;text-align:center} .c11_5{font-weight:bold} .c20_5{background-color:#00ff00} .c6_5{font-style:italic} .c4_5{height:11pt} .c17_5{background-color:#ffff00} .c0_5{direction:ltr} .c7_5{font-family:"Courier New"} .c2_5{border-collapse:collapse} .c1_5{line-height:1.0} .c13_5{background-color:#f3f3f3} .c15_5{height:0pt} .c9_5{text-align:center} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:24pt;font-family:"Arial";font-weight:normal} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:12pt;font-family:"Arial";font-weight:normal} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:11pt;font-family:"Arial";font-weight:normal} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal} Welcome to another post in the series of blogs which demonstrates how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue Today we will create a BPEL process which will read (dequeue) the message from the JMS queue, which we enqueued in the last example. The JMS adapter will dequeue the full XML payload from the queue. 1. Recap and Prerequisites In the previous examples, we created a JMS Queue, a Connection Factory and a Connection Pool in the WebLogic Server Console. Then we designed and deployed a BPEL composite, which took a simple XML payload and enqueued it to the JMS queue. In this example, we will read that same message from the queue, using a JMS adapter and a BPEL process. As many of the configuration steps required to read from that queue were done in the previous samples, this one will concentrate on the new steps. A summary of the required objects is listed below. To find out how to create them please see the previous samples. They also include instructions on how to verify the objects are set up correctly. WebLogic Server Objects Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue Schema XSD File The following XSD file is used for the message format. It was created in the previous example and will be copied to the new process. stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema"                 xmlns="http://www.example.org"                 targetNamespace="http://www.example.org"                 elementFormDefault="qualified">   <xsd:element name="exampleElement" type="xsd:string">   </xsd:element> </xsd:schema> JMS Message After executing the previous samples, the following XML message should be in the JMS queue located at jms/TestJMSQueue: <?xml version="1.0" encoding="UTF-8" ?><exampleElement xmlns="http://www.example.org">Test Message</exampleElement> JDeveloper Connection You will need a valid Application Server Connection in JDeveloper pointing to the SOA server which the process will be deployed to. 2. Create a BPEL Composite with a JMS Adapter Partner Link In the previous example, we created a composite in JDeveloper called JmsAdapterWriteSchema. In this one, we will create a new composite called JmsAdapterReadSchema. There are probably many ways of incorporating a JMS adapter into a SOA composite for incoming messages. One way is design the process in such a way that the adapter polls for new messages and when it dequeues one, initiates a SOA or BPEL instance. This is possibly the most common use case. Other use cases include mid-flow adapters, which are activated from within the BPEL process. In this example we will use a polling adapter, because it is the most simple to set up and demonstrate. But it has one disadvantage as a demonstrative model. When a polling adapter is active, it will dequeue all messages as soon as they reach the queue. This makes it difficult to monitor messages we are writing to the queue, because they will disappear from the queue as soon as they have been enqueued. To work around this, we will shut down the composite after deploying it and restart it as required. (Another solution for this would be to pause the consumption for the queue and resume consumption again if needed. This can be done in the WLS console JMS-Modules -> queue -> Control -> Consumption -> Pause/Resume.) We will model the composite as a one-way incoming process. Usually, a BPEL process will do something useful with the message after receiving it, such as passing it to a database or file adapter, a human workflow or external web service. But we only want to demonstrate how to dequeue a JMS message using BPEL and a JMS adapter, so we won’t complicate the design with further activities. However, we do want to be able to verify that we have read the message correctly, so the BPEL process will include a small piece of embedded java code, which will print the message to standard output, so we can view it in the SOA server’s log file. Alternatively, you can view the instance in the Enterprise Manager and verify the message. The following steps are all executed in JDeveloper. Create the project in the same JDeveloper application used for the previous examples or create a new one. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterReadSchema. When prompted for the composite type, choose Empty Composite. Create a JMS Adapter Partner Link In the composite editor, drag a JMS adapter over from the Component Palette to the left-hand swim lane, under Exposed Services. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterRead Oracle Enterprise Messaging Service (OEMS): Oracle WebLogic JMS AppServer Connection: Use an application server connection pointing to the WebLogic server on which the JMS queue and connection factory mentioned under Prerequisites above are located. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Consume Message Operation Name: Consume_message Consume Operation Parameters Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created in a previous example. JNDI Name: The JNDI name to use for the JMS connection. As in the previous example, this is probably the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) Messages/Message SchemaURL: We will use the XSD file created during the previous example, in the JmsAdapterWriteSchema project to define the format for the incoming message payload and, at the same time, demonstrate how to import an existing XSD file into a JDeveloper project. Press the magnifying glass icon to search for schema files. In the Type Chooser, press the Import Schema File button. Select the magnifying glass next to URL to search for schema files. Navigate to the location of the JmsAdapterWriteSchema project > xsd and select the stringPayload.xsd file. Check the “Copy to Project” checkbox, press OK and confirm the following Localize Files popup. Now that the XSD file has been copied to the local project, it can be selected from the project’s schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string . Press Next and Finish, which will complete the JMS Adapter configuration.Save the project. Create a BPEL Component Drag a BPEL Process from the Component Palette (Service Components) to the Components section of the composite designer. Name it JmsAdapterReadSchema and select Template: Define Service Later and press OK. Wire the JMS Adapter to the BPEL Component Now wire the JMS adapter to the BPEL process, by dragging the arrow from the adapter to the BPEL process. A Transaction Properties popup will be displayed. Set the delivery mode to async.persist. This completes the steps at the composite level. 3 . Complete the BPEL Process Design Invoke the BPEL Flow via the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterReadSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterRead partner link in the left-hand swim lane. Drag a Receive activity onto the BPEL flow diagram, then drag a wire (left-hand yellow arrow) from it to the JMS adapter. This will open the Receive activity editor. Auto-generate the variable by pressing the green “+” button and check the “Create Instance” checkbox. This will result in a BPEL instance being created when a new JMS message is received. At this point it would actually be OK to compile and deploy the composite and it would pick up any messages from the JMS queue. In fact, you can do that to test it, if you like. But it is very rudimentary and would not be doing anything useful with the message. Also, you could only verify the actual message payload by looking at the instance’s flow in the Enterprise Manager. There are various other possibilities; we could pass the message to another web service, write it to a file using a file adapter or to a database via a database adapter etc. But these will all introduce unnecessary complications to our sample. So, to keep it simple, we will add a small piece of Java code to the BPEL process which will write the payload to standard output. This will be written to the server’s log file, which will be easy to monitor. Add a Java Embedding Activity First get the full name of the process’s input variable, as this will be needed for the Java code. Go to the Structure pane and expand Variables > Process > Variables. Then expand the input variable, for example, "Receive1_Consume_Message_InputVariable > body > ns2:exampleElement”, and note variable’s name and path, if they are different from this one. Drag a Java Embedding activity from the Component Palette (Oracle Extensions) to the BPEL flow, after the Receive activity, then open it to edit. Delete the example code and replace it with the following, replacing the variable parts with those in your sample, if necessary.: System.out.println("JmsAdapterReadSchema process picked up a message"); oracle.xml.parser.v2.XMLElement inputPayload =    (oracle.xml.parser.v2.XMLElement)getVariableData(                           "Receive1_Consume_Message_InputVariable",                           "body",                           "/ns2:exampleElement");   String inputString = inputPayload.getFirstChild().getNodeValue(); System.out.println("Input String is " + inputPayload.getFirstChild().getNodeValue()); Tip. If you are not sure of the exact syntax of the input variable, create an Assign activity in the BPEL process and copy the variable to another, temporary one. Then check the syntax created by the BPEL designer. This completes the BPEL process design in JDeveloper. Save, compile and deploy the process to the SOA server. 3. Test the Composite Shut Down the JmsAdapterReadSchema Composite After deploying the JmsAdapterReadSchema composite to the SOA server it is automatically activated. If there are already any messages in the queue, the adapter will begin polling them. To ease the testing process, we will deactivate the process first Log in to the Enterprise Manager (Fusion Middleware Control) and navigate to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterReadSchema [1.0] . Press the Shut Down button to disable the composite and confirm the following popup. Monitor Messages in the JMS Queue In a separate browser window, log in to the WebLogic Server Console and navigate to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. This is the location of the JMS queue we created in an earlier sample (see the prerequisites section of this sample). Check whether there are any messages already in the queue. If so, you can dequeue them using the QueueReceive Java program created in an earlier sample. This will ensure that the queue is empty and doesn’t contain any messages in the wrong format, which would cause the JmsAdapterReadSchema to fail. Send a Test Message In the Enterprise Manager, navigate to the JmsAdapterWriteSchema created earlier, press Test and send a test message, for example “Message from JmsAdapterWriteSchema”. Confirm that the message was written correctly to the queue by verifying it via the queue monitor in the WLS Console. Monitor the SOA Server’s Output A program deployed on the SOA server will write its standard output to the terminal window in which the server was started, unless this has been redirected to somewhere else, for example to a file. If it has not been redirected, go to the terminal session in which the server was started, otherwise open and monitor the file to which it was redirected. Re-Enable the JmsAdapterReadSchema Composite In the Enterprise Manager, navigate to the JmsAdapterReadSchema composite again and press Start Up to re-enable it. This should cause the JMS adapter to dequeue the test message and the following output should be written to the server’s standard output: JmsAdapterReadSchema process picked up a message. Input String is Message from JmsAdapterWriteSchema Note that you can also monitor the payload received by the process, by navigating to the the JmsAdapterReadSchema’s Instances tab in the Enterprise Manager. Then select the latest instance and view the flow of the BPEL component. The Receive activity will contain and display the dequeued message too. 4 . Troubleshooting This sample demonstrates how to dequeue an XML JMS message using a BPEL process and no additional functionality. For example, it doesn’t contain any error handling. Therefore, any errors in the payload will result in exceptions being written to the log file or standard output. If you get any errors related to the payload, such as Message handle error ... ORABPEL-09500 ... XPath expression failed to execute. An error occurs while processing the XPath expression; the expression is /ns2:exampleElement. ... etc. check that the variable used in the Java embedding part of the process was entered correctly. Possibly follow the tip mentioned in previous section. If this doesn’t help, you can delete the Java embedding part and simply verify the message via the flow diagram in the Enterprise Manager. Or use a different method, such as writing it to a file via a file adapter. This concludes this example. In the next post, we will begin with an AQ JMS example, which uses JMS to write to an Advanced Queue stored in the database. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • Informed TDD &ndash; Kata &ldquo;To Roman Numerals&rdquo;

    - by Ralf Westphal
    Originally posted on: http://geekswithblogs.net/theArchitectsNapkin/archive/2014/05/28/informed-tdd-ndash-kata-ldquoto-roman-numeralsrdquo.aspxIn a comment on my article on what I call Informed TDD (ITDD) reader gustav asked how this approach would apply to the kata “To Roman Numerals”. And whether ITDD wasn´t a violation of TDD´s principle of leaving out “advanced topics like mocks”. I like to respond with this article to his questions. There´s more to say than fits into a commentary. Mocks and TDD I don´t see in how far TDD is avoiding or opposed to mocks. TDD and mocks are orthogonal. TDD is about pocess, mocks are about structure and costs. Maybe by moving forward in tiny red+green+refactor steps less need arises for mocks. But then… if the functionality you need to implement requires “expensive” resource access you can´t avoid using mocks. Because you don´t want to constantly run all your tests against the real resource. True, in ITDD mocks seem to be in almost inflationary use. That´s not what you usually see in TDD demonstrations. However, there´s a reason for that as I tried to explain. I don´t use mocks as proxies for “expensive” resource. Rather they are stand-ins for functionality not yet implemented. They allow me to get a test green on a high level of abstraction. That way I can move forward in a top-down fashion. But if you think of mocks as “advanced” or if you don´t want to use a tool like JustMock, then you don´t need to use mocks. You just need to stand the sight of red tests for a little longer ;-) Let me show you what I mean by that by doing a kata. ITDD for “To Roman Numerals” gustav asked for the kata “To Roman Numerals”. I won´t explain the requirements again. You can find descriptions and TDD demonstrations all over the internet, like this one from Corey Haines. Now here is, how I would do this kata differently. 1. Analyse A demonstration of TDD should never skip the analysis phase. It should be made explicit. The requirements should be formalized and acceptance test cases should be compiled. “Formalization” in this case to me means describing the API of the required functionality. “[D]esign a program to work with Roman numerals” like written in this “requirement document” is not enough to start software development. Coding should only begin, if the interface between the “system under development” and its context is clear. If this interface is not readily recognizable from the requirements, it has to be developed first. Exploration of interface alternatives might be in order. It might be necessary to show several interface mock-ups to the customer – even if that´s you fellow developer. Designing the interface is a task of it´s own. It should not be mixed with implementing the required functionality behind the interface. Unfortunately, though, this happens quite often in TDD demonstrations. TDD is used to explore the API and implement it at the same time. To me that´s a violation of the Single Responsibility Principle (SRP) which not only should hold for software functional units but also for tasks or activities. In the case of this kata the API fortunately is obvious. Just one function is needed: string ToRoman(int arabic). And it lives in a class ArabicRomanConversions. Now what about acceptance test cases? There are hardly any stated in the kata descriptions. Roman numerals are explained, but no specific test cases from the point of view of a customer. So I just “invent” some acceptance test cases by picking roman numerals from a wikipedia article. They are supposed to be just “typical examples” without special meaning. Given the acceptance test cases I then try to develop an understanding of the problem domain. I´ll spare you that. The domain is trivial and is explain in almost all kata descriptions. How roman numerals are built is not difficult to understand. What´s more difficult, though, might be to find an efficient solution to convert into them automatically. 2. Solve The usual TDD demonstration skips a solution finding phase. Like the interface exploration it´s mixed in with the implementation. But I don´t think this is how it should be done. I even think this is not how it really works for the people demonstrating TDD. They´re simplifying their true software development process because they want to show a streamlined TDD process. I doubt this is helping anybody. Before you code you better have a plan what to code. This does not mean you have to do “Big Design Up-Front”. It just means: Have a clear picture of the logical solution in your head before you start to build a physical solution (code). Evidently such a solution can only be as good as your understanding of the problem. If that´s limited your solution will be limited, too. Fortunately, in the case of this kata your understanding does not need to be limited. Thus the logical solution does not need to be limited or preliminary or tentative. That does not mean you need to know every line of code in advance. It just means you know the rough structure of your implementation beforehand. Because it should mirror the process described by the logical or conceptual solution. Here´s my solution approach: The arabic “encoding” of numbers represents them as an ordered set of powers of 10. Each digit is a factor to multiply a power of ten with. The “encoding” 123 is the short form for a set like this: {1*10^2, 2*10^1, 3*10^0}. And the number is the sum of the set members. The roman “encoding” is different. There is no base (like 10 for arabic numbers), there are just digits of different value, and they have to be written in descending order. The “encoding” XVI is short for [10, 5, 1]. And the number is still the sum of the members of this list. The roman “encoding” thus is simpler than the arabic. Each “digit” can be taken at face value. No multiplication with a base required. But what about IV which looks like a contradiction to the above rule? It is not – if you accept roman “digits” not to be limited to be single characters only. Usually I, V, X, L, C, D, M are viewed as “digits”, and IV, IX etc. are viewed as nuisances preventing a simple solution. All looks different, though, once IV, IX etc. are taken as “digits”. Then MCMLIV is just a sum: M+CM+L+IV which is 1000+900+50+4. Whereas before it would have been understood as M-C+M+L-I+V – which is more difficult because here some “digits” get subtracted. Here´s the list of roman “digits” with their values: {1, I}, {4, IV}, {5, V}, {9, IX}, {10, X}, {40, XL}, {50, L}, {90, XC}, {100, C}, {400, CD}, {500, D}, {900, CM}, {1000, M} Since I take IV, IX etc. as “digits” translating an arabic number becomes trivial. I just need to find the values of the roman “digits” making up the number, e.g. 1954 is made up of 1000, 900, 50, and 4. I call those “digits” factors. If I move from the highest factor (M=1000) to the lowest (I=1) then translation is a two phase process: Find all the factors Translate the factors found Compile the roman representation Translation is just a look-up. Finding, though, needs some calculation: Find the highest remaining factor fitting in the value Remember and subtract it from the value Repeat with remaining value and remaining factors Please note: This is just an algorithm. It´s not code, even though it might be close. Being so close to code in my solution approach is due to the triviality of the problem. In more realistic examples the conceptual solution would be on a higher level of abstraction. With this solution in hand I finally can do what TDD advocates: find and prioritize test cases. As I can see from the small process description above, there are two aspects to test: Test the translation Test the compilation Test finding the factors Testing the translation primarily means to check if the map of factors and digits is comprehensive. That´s simple, even though it might be tedious. Testing the compilation is trivial. Testing factor finding, though, is a tad more complicated. I can think of several steps: First check, if an arabic number equal to a factor is processed correctly (e.g. 1000=M). Then check if an arabic number consisting of two consecutive factors (e.g. 1900=[M,CM]) is processed correctly. Then check, if a number consisting of the same factor twice is processed correctly (e.g. 2000=[M,M]). Finally check, if an arabic number consisting of non-consecutive factors (e.g. 1400=[M,CD]) is processed correctly. I feel I can start an implementation now. If something becomes more complicated than expected I can slow down and repeat this process. 3. Implement First I write a test for the acceptance test cases. It´s red because there´s no implementation even of the API. That´s in conformance with “TDD lore”, I´d say: Next I implement the API: The acceptance test now is formally correct, but still red of course. This will not change even now that I zoom in. Because my goal is not to most quickly satisfy these tests, but to implement my solution in a stepwise manner. That I do by “faking” it: I just “assume” three functions to represent the transformation process of my solution: My hypothesis is that those three functions in conjunction produce correct results on the API-level. I just have to implement them correctly. That´s what I´m trying now – one by one. I start with a simple “detail function”: Translate(). And I start with all the test cases in the obvious equivalence partition: As you can see I dare to test a private method. Yes. That´s a white box test. But as you´ll see it won´t make my tests brittle. It serves a purpose right here and now: it lets me focus on getting one aspect of my solution right. Here´s the implementation to satisfy the test: It´s as simple as possible. Right how TDD wants me to do it: KISS. Now for the second equivalence partition: translating multiple factors. (It´a pattern: if you need to do something repeatedly separate the tests for doing it once and doing it multiple times.) In this partition I just need a single test case, I guess. Stepping up from a single translation to multiple translations is no rocket science: Usually I would have implemented the final code right away. Splitting it in two steps is just for “educational purposes” here. How small your implementation steps are is a matter of your programming competency. Some “see” the final code right away before their mental eye – others need to work their way towards it. Having two tests I find more important. Now for the next low hanging fruit: compilation. It´s even simpler than translation. A single test is enough, I guess. And normally I would not even have bothered to write that one, because the implementation is so simple. I don´t need to test .NET framework functionality. But again: if it serves the educational purpose… Finally the most complicated part of the solution: finding the factors. There are several equivalence partitions. But still I decide to write just a single test, since the structure of the test data is the same for all partitions: Again, I´m faking the implementation first: I focus on just the first test case. No looping yet. Faking lets me stay on a high level of abstraction. I can write down the implementation of the solution without bothering myself with details of how to actually accomplish the feat. That´s left for a drill down with a test of the fake function: There are two main equivalence partitions, I guess: either the first factor is appropriate or some next. The implementation seems easy. Both test cases are green. (Of course this only works on the premise that there´s always a matching factor. Which is the case since the smallest factor is 1.) And the first of the equivalence partitions on the higher level also is satisfied: Great, I can move on. Now for more than a single factor: Interestingly not just one test becomes green now, but all of them. Great! You might say, then I must have done not the simplest thing possible. And I would reply: I don´t care. I did the most obvious thing. But I also find this loop very simple. Even simpler than a recursion of which I had thought briefly during the problem solving phase. And by the way: Also the acceptance tests went green: Mission accomplished. At least functionality wise. Now I´ve to tidy up things a bit. TDD calls for refactoring. Not uch refactoring is needed, because I wrote the code in top-down fashion. I faked it until I made it. I endured red tests on higher levels while lower levels weren´t perfected yet. But this way I saved myself from refactoring tediousness. At the end, though, some refactoring is required. But maybe in a different way than you would expect. That´s why I rather call it “cleanup”. First I remove duplication. There are two places where factors are defined: in Translate() and in Find_factors(). So I factor the map out into a class constant. Which leads to a small conversion in Find_factors(): And now for the big cleanup: I remove all tests of private methods. They are scaffolding tests to me. They only have temporary value. They are brittle. Only acceptance tests need to remain. However, I carry over the single “digit” tests from Translate() to the acceptance test. I find them valuable to keep, since the other acceptance tests only exercise a subset of all roman “digits”. This then is my final test class: And this is the final production code: Test coverage as reported by NCrunch is 100%: Reflexion Is this the smallest possible code base for this kata? Sure not. You´ll find more concise solutions on the internet. But LOC are of relatively little concern – as long as I can understand the code quickly. So called “elegant” code, however, often is not easy to understand. The same goes for KISS code – especially if left unrefactored, as it is often the case. That´s why I progressed from requirements to final code the way I did. I first understood and solved the problem on a conceptual level. Then I implemented it top down according to my design. I also could have implemented it bottom-up, since I knew some bottom of the solution. That´s the leaves of the functional decomposition tree. Where things became fuzzy, since the design did not cover any more details as with Find_factors(), I repeated the process in the small, so to speak: fake some top level, endure red high level tests, while first solving a simpler problem. Using scaffolding tests (to be thrown away at the end) brought two advantages: Encapsulation of the implementation details was not compromised. Naturally private methods could stay private. I did not need to make them internal or public just to be able to test them. I was able to write focused tests for small aspects of the solution. No need to test everything through the solution root, the API. The bottom line thus for me is: Informed TDD produces cleaner code in a systematic way. It conforms to core principles of programming: Single Responsibility Principle and/or Separation of Concerns. Distinct roles in development – being a researcher, being an engineer, being a craftsman – are represented as different phases. First find what, what there is. Then devise a solution. Then code the solution, manifest the solution in code. Writing tests first is a good practice. But it should not be taken dogmatic. And above all it should not be overloaded with purposes. And finally: moving from top to bottom through a design produces refactored code right away. Clean code thus almost is inevitable – and not left to a refactoring step at the end which is skipped often for different reasons.   PS: Yes, I have done this kata several times. But that has only an impact on the time needed for phases 1 and 2. I won´t skip them because of that. And there are no shortcuts during implementation because of that.

    Read the article

  • Installing XP through USB-flash disc

    - by Crazy Buddy
    I don't know whether this could be asked here... So, Pardon me for this. Probably, this is based on My laptop and a contradiction to this question asked already here... I tried to format my "government-provided" laptop (No CD-drive). I thought those IT guys are proving that they're too smart..! I have the Windows XP CD right now. I didn't like to stick with some home-made OS from our Government. So, I used another laptop to format the govt. thing and tried to install XP (As I didn't have enough bills to invest on Windows 7 or 8). Case 1: First, I allowed WinSetupFromUSB 1.0 beta 8 to deal with the flash disk. I wondered for the first time that XP text-screen appeared. Using the first part, I formatted my laptop. It started to copy files, entered into the next part, and completed the installation. I started my PC for the first time. XP splash screen appeared. Suddenly, a blue screen flashed and disappeared (I can't even read what it says). Rebooted and arrived at the screen, "Start Windows Normally". It happens and happens still - like an infinite loop :-) Case 2: Next, I used Rufus 1.2.0 to transfer files to my Flash and it screwed everything out. Even if I used Flash to boot, it arrives to the same screen "Start Windows normally". It doesn't show any response of Flash being inserted. Then I recognized that, It's simply copies everything to the flash disk. Case 3: Then, I started with Novicorp WinToFlash (giving utmost priority to this site). I booted with the disk. I entered into the first part - "Text mode". Some lines started running like that "Press F6 if you..." like that. The last thing I saw was, "Setup is starting Windows..." Suddenly a blue screen appeared like this captured one. I've a suspicion that the same screen appears again & again in first case. Man, I'm dead. Case 4: For the sake of my last hope, I used WinSetupFromUSB 0.1.1. I was shocked on arriving at a screen which says something "GRUB4DOS" like that and some commands like {command line, reboot, halt, \find menu.lst} and when I go inside those "find" options, I see "Error:15 - File not found". Googling provided some commands to mount SETUPLDR.BIN file in the "grub" thing which also proved unsuccessful... Some sites say that Factory reset uses only some function keys. A guy said that it's F11 for lenovo. Screw him. It's all a waste-of-time. But, I think SE would help me out. Is our government IT guys doin' this to me? Are they Soooo smart to spark some blue screen in front of me to freak me out? Any suggestions or new (useful) USB transferring things would be appreciated. It's very urgent. So, It'd be better if you guys pay some attention in debugging and help me out..? Thanks for your time guys :-)

    Read the article

  • Using PHP to connect to RADIUS works on one server but not another

    - by JDS
    I have a fleet of webservers that server a LAMP webapp broken into multiple customer apps by virtualhost/domain. The platform is Ubuntu 10.04 VM + PHP 5.3 + Apache 2.2.14, on top of VMware ESX (v4 I think). This stuff's not too important, though -- I'm just setting up the background. I have one customer that connects to a RADIUS server for authentication. We've found that the app responds as if some number of web servers are configured correctly and some are not. i.e. Apparently random authentication failures or successes, with no rhyme or reason. I did a lot of analysis of our fleet, and resolved it down to the differences between two specific web servers. I'll call them "A" and "B". "A" works. "B" does not. "Works" means "connects to and gets authentication data successfully from the RADIUS server". Ultimately, I'm looking for one thing that is different, and I've exhausted everything that I can come up with, so, looking for something else. Here are things I've looked at PHP package versions (all from Ubuntu repos). These are exactly the same across servers. PECL package. There are no PECL packages that aren't installed by apt. Other libraries or packages. Nothing that was network-related or RADIUS-related was different among servers. (There were some minor package differences, though.) Network or hosting environment. I found that some of the working servers were on the same physical environment as some not-working ones (i.e. same ESX containers). So, probably, the physical network layer is not the problem. Test case. I created a test case as follows. It works on the working servers, and fails on the not-working servers, very consistently. <?php $radius = radius_auth_open(); $username = 'theusername'; $password = 'thepassword'; $hostname = '12.34.56.78'; $radius_secret = '39wmmvxghg'; if (! radius_add_server($radius,$hostname,0,$radius_secret,5,3)) { die('Radius Error 1: ' . radius_strerror($radius) . "\n"); } if (! radius_create_request($radius,RADIUS_ACCESS_REQUEST)) { die('Radius Error 2: ' . radius_strerror($radius) . "\n"); } radius_put_attr($radius,RADIUS_USER_NAME,$username); radius_put_attr($radius,RADIUS_USER_PASSWORD,$password); switch (radius_send_request($radius)) { case RADIUS_ACCESS_ACCEPT: echo 'GOOD LOGIN'; break; case RADIUS_ACCESS_REJECT: echo 'BAD LOGIN'; break; case RADIUS_ACCESS_CHALLENGE: echo 'CHALLENGE REQUESTED'; break; default: die('Radius Error 3: ' . radius_strerror($radius) . "\n"); } ?>

    Read the article

  • How to Submit Form Given Specific Json Response

    - by dentalhero
    I'm new to Json, so please excuse the newb question. I have a form in which I'm conducting an Ajax post to submit address information to a backend script for validation. Here's the form: <form name="Form" id="Forms" method="post" action="WebCatPageServer.exe" class="uniForm"> <input name="Action" type="hidden" value="SHIPTOVALIDATE"/> <input name="IsAjax" type="hidden" value="Yes"/> <!-- <input name="Action" type="hidden" value="VerifyOrder"/>--> <fieldset class="inlineLabels top"> <h2>Order Details</h2> <div class="ctrlHolder first"> <label for="orderdesc">Order Description</label> <input name="Order Desc" id="OrderDesc" type="text" class="textInput small" tabindex="1" value=""/> </div> <div class="ctrlHolder"> <label for="po">PO # <span class="redasterisk">*</span></label> <input name="Cust Po" id="PoJobNo" type="text" class="textInput small required" maxlength="20" tabindex="2" value="dgnfg"/> </div> <!-- <div class="ctrlHolder"> <label for="jobname">Job Name</label> <input name="Job Name" id="CustJobName" type="text" class="textInput small" maxlength="15" tabindex="3" value=""/> </div> --> <div class="ctrlHolder"> <label for="shipvia">Ship Via <span class="redasterisk">*</span></label> <select name="Ship Via" id="shipvia" class="selectInput small required" tabindex="4"/> <option value="" class="default">Select Ship Method</option> <option value="OT - Our Truck" class="del" selected>Our Truck</option> <option value="WC - Will Call" class="pick">Will Call</option> </select> </div> <div class="ctrlHolder" id="pickupdate"> <label for="datepickup">Requested Pickup Date <span class="redasterisk">*</span></label> <input name="datepickup" id="datepickup" type="text" class="textInput small" tabindex="5" value="11/09/2012"> </div> <div class="ctrlHolder" id="shipdate"> <label for="dateship">Requested Delivery Date <span class="redasterisk">*</span></label> <input name="dateship" id="dateship" type="text" class="textInput small" value="" tabindex="6"> </div> <div class="ctrlHolder" id="shipto"> <label for="ShipTo">Ship To <span class="redasterisk">*</span></label> <select name="ShipTos" id="ShipTos" class="selectInput auto required" tabindex="7"> <option value="">Select an Option</option> <option value="ShipToManual" class="manual">Manually Enter Address</option> <option value="0">A ACTION AIR*, 5241 YANCEYVILLE, COLUMBIA, SC 29214-0001</option> <option value="1">A ACTION AIR*, 649 spring lane, sanford, NC 27330</option> <option value="2">A ACTION AIR*, 1313 south briggs avenue, durham, NC 27703</option> <option value="3">A ACTION AIR*, 112 cricket hill lane, cary, NC 27513</option> <option value="4">A ACTION AIR*, 2911 duke homestead road, durham, NC 27705</option> <option value="5">A ACTION AIR*, chickem poop, atlanta, GA 60609</option> </select> <br /> </div> </fieldset> <fieldset class="inlineLabels" id="shipinfo"> <h2>Shipping Information</h2> <div class="ctrlHolder first"> <label for="YourName">Your Name <span class="redasterisk">*</span></label> <input name="Your Name" id="Your_Name" type="text" class="textInput small required" tabindex="8" value="" /> </div> <div class="ctrlHolder"> <label for="CompanyName">Company Name <span class="redasterisk">*</span></label> <input name="Company Name" id="CompanyName" type="text" class="textInput small required" tabindex="9" value="A ACTION AIR*"/> </div> <div class="ctrlHolder"> <label for="Address1">Address 1 <span class="redasterisk">*</span></label> <input name="Address_1" id="Address_1" type="text" maxlength="30" class="textInput small required" tabindex="10" value="5241 YANCEYVILLE"/> </div> <div class="ctrlHolder"> <label for="Address2">Address 2</label> <input name="Address_2" id="Address_2" type="text" maxlength="30" class="textInput small" tabindex="11" value=""/> </div> <div class="ctrlHolder"> <label for="City">City <span class="redasterisk">*</span></label> <input name="City" id="City" type="text" maxlength="25" class="textInput small required" tabindex="12" value="COLUMBIA"/> </div> <div class="ctrlHolder"> <label for="State">State <span class="redasterisk">*</span></label> <select name="State" id="State" class="selectInput small required" tabindex="13"> <option value="">Select State</option> <option value="AL">Alabama</option> <option value="AK">Alaska</option> <option value="AZ">Arizona</option> <option value="AR">Arkansas</option> <option value="CA">California</option> <option value="CO">Colorado</option> <option value="CT">Connecticut</option> <option value="DE">Delaware</option> <option value="FL">Florida</option> <option value="GA">Georgia</option> <option value="HI">Hawaii</option> <option value="ID">Idaho</option> <option value="IL">Illinois</option> <option value="IN">Indiana</option> <option value="IA">Iowa</option> <option value="KS">Kansas</option> <option value="KY">Kentucky</option> <option value="LA">Louisiana</option> <option value="ME">Maine</option> <option value="MD">Maryland</option> <option value="MA">Massachussetts</option> <option value="MI">Michigan</option> <option value="MN">Minnesota</option> <option value="MS">Mississippi</option> <option value="MO">Missouri</option> <option value="MT">Montana</option> <option value="NE">Nebraska</option> <option value="NV">Nevada</option> <option value="NH">New Hampshire</option> <option value="NJ">New Jersey</option> <option value="NM">New Mexico</option> <option value="NY">New York</option> <option value="NC">North Carolina</option> <option value="ND">North Dakota</option> <option value="OH">Ohio</option> <option value="OK">Oklahoma</option> <option value="OR">Oregon</option> <option value="PA">Pennsylvania</option> <option value="RI">Rhode Island</option> <option value="SC" selected>South Carolina</option> <option value="SD">South Dakota</option> <option value="TN">Tennessee</option> <option value="TX">Texas</option> <option value="UT">Utah</option> <option value="VT">Vermont</option> <option value="VA">Virginia</option> <option value="WA">Washington</option> <option value="WV">West Virginia</option> <option value="WI">Wisconsin</option> <option value="WY">Wyoming</option> </select> </div> <div class="ctrlHolder"> <label for="ZipCode">Zip Code <span class="redasterisk">*</span></label> <input name="Zip" id="Zip" type="text" maxlength="10" class="textInput small required zipcode" tabindex="14" value=""/> </div> <div class="ctrlHolder"> <label for="Phone">Phone <span class="redasterisk">*</span></label> <input name="Phone Number" id="Phone" type="text" class="textInput small required phone" alt="phone-us" tabindex="15" value="(336)954-5009"/> </div> <div class="ctrlHolder"> <label for="Fax">Fax</label> <input name="FaxNumber" id="Fax Number" type="text" class="textInput small fax" alt="phone-us" tabindex="16" value=""/> </div> <div class="ctrlHolder"> <label for="">E-mail <span class="redasterisk">*</span></label> <input name="Email" id="Email" type="text" class="textInput small required email" tabindex="17" value=""/> </div> </fieldset> <fieldset class="inlineLabels"> <h2>Order/Shipping Notes</h2> <div class="ctrlHolder first"> <label for="notes">Order Notes </label> <textarea name="OrderNotes" id="ta" cols="26" rows="7" tabindex="18"></textarea><br /> <p class="formHint"><b>(Maximum characters: 175) &nbsp; <span id="charLeft"></span> &nbsp; Characters left</b><br /> (Cross streets, special instructions, etc.)</p> <br /> </div> </fieldset> <fieldset class="inlineLabels"> <h2>Continue To Next Step</h2> <div class="buttonHolder"> <label for="freightmsg">**Applicable freight charges will be applied at the time of invoicing.**</label> <input name="continuetocheckout" type="submit" class="button red smallrounded" value="Continue &gt;" alt="Continue to Next Step" tabindex="20"/> </div> </fieldset> </form> AJAX Call Here's the AJAX call: $(function() { $("#Forms").submit(function() { $.ajax({ type: 'post', url: 'WebCatPageServer.exe', dataType : 'json', data: $("#Forms").serialize(), complete:function(data){ alert(data); } }); return false; }); }); JSON Response Here's the JSON response: {"DidValidate":true,"Company Name":"A ACTION AIR*","AddrLine1":"5241 YANCEYVILLE","AddrLine2":"","City":"COLUMBIA","State":"SC","Zip":"","Modified":false,"AddressError":false,"ZipError":false} Question: How do I submit the form programatically if both AddressError and ZipError return with a false?

    Read the article

  • passing values to php print page

    - by DAFFODIL
    In this wen i select a value in drop down box it will list out that name value in table .There will be a check box ,the checked values should be passed to pring page which is below the 1st part of code. Any help ii be appreciated <?php $con = mysql_connect("localhost","root",""); if (!$con) { die('Could not connect: ' . mysql_error()); } mysql_select_db("form1", $con); error_reporting(E_ALL ^ E_NOTICE); $nam=$_REQUEST['select1']; $row=mysql_query("select * from inv where name='$nam'"); while($row1=mysql_fetch_array($row)) { $Name=$row1['Name']; $Address =$row1['Address']; $City=$row1['City']; $Pincode=$row1['Pincode']; $No=$row1['No']; $Date=$row1['Date']; $DCNo=$row1['DCNo']; $DcDate=$row1['DcDate']; $YourOrderNo=$row1['YourOrderNo']; $OrderDate=$row1['OrderDate']; $VendorCode=$row1['VendorCode']; $SNo=$row1['SNo']; $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; } ?> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml"> <head> <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1" /> <title>Untitled Document</title> <script type="text/javascript"> function ram() { var q=document.getElementById('qty').value; var r=document.getElementById('rate').value; document.getElementById('amt').value=q*r; } </script> </head> <body> <form id="form1" name="form1" method="post" action=""> <table width="1315" border="0"> <script type="text/javascript"> function g() { form1.submit(); } </script> <tr> <th>Name</th> <th align="left"><select name="select1" onchange="g();"> <option value="" selected="selected">select</option> <?php $row=mysql_query("select Name from inv "); while($row1=mysql_fetch_array($row)) { ?> <option value="<?php echo $row1['Name'];?>"><?php echo $row1['Name'];?></option> <?php } ?> </select></th> </tr> <tr> <th>Address</th> <th align="left"><textarea name="Address"><?php echo $Address;?></textarea></th> </tr> <tr> <th>City</th> <th align="left"><input type="text" name="City" value='<?php echo $City;?>' /></th> </tr> <tr> <th>Pincode</th> <th align="left"><input type="text" name="Pincode" value='<?php echo $Pincode;?>'></th> </tr> <tr> <th>No</th> <th align="left"><input type="text" name="No2" value='<?php echo $No;?>' readonly="" /></th> </tr> <tr> <th>Date</th> <th align="left"><input type="text" name="Date" value='<?php echo $Date;?>' readonly="" /></th> </tr> <tr> <th>DCNo</th> <th align="left"><input type="text" name="DCNo" value='<?php echo $DCNo;?>' readonly="" /></th> </tr> <tr> <th>DcDate:</th> <th align="left"><input type="text" name="DcDate" value='<?php echo $DcDate;?>' /></th> </tr> <tr> <th>YourOrderNo</th> <th align="left"><input type="text" name="YourOrderNo" value='<?php echo $YourOrderNo;?>' readonly="" /></th> </tr> <tr> <th>OrderDate</th> <th align="left"><input type="text" name="OrderDate" value='<?php echo $OrderDate;?>' readonly="" /></th> </tr> <tr> <th width="80">VendorCode</th> <th width="1225" align="left"><input type="text" name="VendorCode" value='<?php echo $VendorCode;?>' readonly="" /></th> </tr> </table> <table width="1313" border="0"> <tr> <td width="44">&nbsp;</td> <td width="71">SNO</td> <td width="527">DESCRIPTION</td> <td width="214">QUANTITY</td> <td width="214">RATE/UNIT</td> <td width="217">AMOUNT</td> </tr> <?php $i=1; $row=mysql_query("select * from inv where Name='$nam'"); while($row1=mysql_fetch_array($row)) { $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; ?> <tr> <td><input type="checkbox" name="checkbox" value="checkbox" /></td> <td><input type="text" name="No" value='<?php echo $No;?>' readonly=""/></td> <td><input type="text" name="descofgoods" value='<?php echo $descofgoods;?>' /></td> <td><input type="text" name="qty" maxlength="50000000" id="qty"/></td> <td><input type="text" name="Rate" value='<?php echo $Rate;?>' id="rate" onclick="ram()";></td> <td><input type="text" name="Amount" id="amt"/></td> </tr> <?php $i++;} ?> <tr> <th colspan="2"><a href="pp.php?msg=<?php echo $nam;?>">Print</a></th> </tr> </table> <label></label> </form> </body> </html> - <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml"> <head> <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1" /> <title></title> <script type = "text/javascript"> function a() { var q = document.getElementsByName('Amount'); var count = 0; for (i = 0; i < q.length; i++) count += parseInt(q[i].value,10); document.getElementById('s').value = count; } </script> </head> <?php $con = mysql_connect("localhost","root",""); if (!$con) { die('Could not connect: ' . mysql_error()); } mysql_select_db("form1", $con); error_reporting(E_ALL ^ E_NOTICE); $nam=$_GET['msg']; $row=mysql_query("select * from inv where Name='$nam'"); while($row1=mysql_fetch_array($row)) { $Name=$row1['Name']; $Address =$row1['Address']; $City=$row1['City']; $Pincode=$row1['Pincode']; $No=$row1['No']; $Date=$row1['Date']; $DCNo=$row1['DCNo']; $DcDate=$row1['DcDate']; $YourOrderNo=$row1['YourOrderNo']; $OrderDate=$row1['OrderDate']; $VendorCode=$row1['VendorCode']; $SNo=$row1['SNo']; $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; } ?> <body> <form id="form1" name="form1" method="post" action=""> <table width="846" border="0"> <tr> <td width="411" height="113">&nbsp;</td> <td width="412">&nbsp;</td> </tr> </table> <table width="846" border="0"> <tr> <td height="38">&nbsp;</td> </tr> </table> <table width="846" border="0"> <tr> <td width="390" rowspan="4">&nbsp;</td> <td width="92" height="35">&nbsp;</td> <td width="136"><?php echo $No;?></td> <td width="36">&nbsp;</td> <td width="170"><?php echo $Date;?></td> </tr> <tr> <td height="37">&nbsp;</td> <td><?php echo $DCNo;?></td> <td>&nbsp;</td> <td><?php echo $DcDate;?></td> </tr> <tr> <td height="34">&nbsp;</td> <td><?php echo $YourOrderNo;?></td> <td>&nbsp;</td> <td><?php echo $OrderDate;?></td> </tr> <tr> <td height="29">&nbsp;</td> <td><?php echo $VendorCode;?></td> <td>&nbsp;</td> <td>&nbsp;</td> </tr> </table> <table width="845" border="0"> <tr> <td height="38">&nbsp;</td> <td>&nbsp;</td> <td>&nbsp;</td> <td>&nbsp;</td> <td>&nbsp;</td> </tr> <tr> <td width="34">&nbsp;</td> <td width="457">&nbsp;</td> <td width="104">&nbsp;</td> <td width="79">&nbsp;</td> <td width="149">&nbsp;</td> </tr> <?php $i=1; $row=mysql_query("select * from inv where Name='$nam'"); while($row1=mysql_fetch_array($row)) { $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; ?> <tr> <td><?php echo $i;?></td> <td><?php echo $descofgoods;?></td> <td><?php echo $Qty;?></td> <td><?php echo $Rate;?></td> <td><input name="Amount" type = "text" value="<?php echo $Amount; ?>" /></td> </tr> <?php $i++;} ?> </table> <table width="844" border="0"> <tr> <td width="495" height="1065">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <input type="text" name="textfield2" width="150" /> &nbsp; &nbsp; &nbsp; &nbsp; </td> <td width="191">&nbsp;</td> <td width="144"><input type="text" name="to" id="s" onclick="a()";/></td> </tr> </table> </form> </body> </html>

    Read the article

  • Removing the XML Formatter from ASP.NET Web API Applications

    - by Rick Strahl
    ASP.NET Web API's default output format is supposed to be JSON, but when I access my Web APIs using the browser address bar I'm always seeing an XML result instead. When working on AJAX application I like to test many of my AJAX APIs with the browser while working on them. While I can't debug all requests this way, GET requests are easy to test in the browser especially if you have JSON viewing options set up in your various browsers. If I preview a Web API request in most browsers I get an XML response like this: Why is that? Web API checks the HTTP Accept headers of a request to determine what type of output it should return by looking for content typed that it has formatters registered for. This automatic negotiation is one of the great features of Web API because it makes it easy and transparent to request different kinds of output from the server. In the case of browsers it turns out that most send Accept headers that look like this (Chrome in this case): Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8 Web API inspects the entire list of headers from left to right (plus the quality/priority flag q=) and tries to find a media type that matches its list of supported media types in the list of formatters registered. In this case it matches application/xml to the Xml formatter and so that's what gets returned and displayed. To verify that Web API indeed defaults to JSON output by default you can open the request in Fiddler and pop it into the Request Composer, remove the application/xml header and see that the output returned comes back in JSON instead. An accept header like this: Accept: text/html,application/xhtml+xml,*/*;q=0.9 or leaving the Accept header out altogether should give you a JSON response. Interestingly enough Internet Explorer 9 also displays JSON because it doesn't include an application/xml Accept header: Accept: text/html, application/xhtml+xml, */* which for once actually seems more sensible. Removing the XML Formatter We can't easily change the browser Accept headers (actually you can by delving into the config but it's a bit of a hassle), so can we change the behavior on the server? When working on AJAX applications I tend to not be interested in XML results and I always want to see JSON results at least during development. Web API uses a collection of formatters and you can go through this list and remove the ones you don't want to use - in this case the XmlMediaTypeFormatter. To do this you can work with the HttpConfiguration object and the static GlobalConfiguration object used to configure it: protected void Application_Start(object sender, EventArgs e) { // Action based routing (used for RPC calls) RouteTable.Routes.MapHttpRoute( name: "StockApi", routeTemplate: "stocks/{action}/{symbol}", defaults: new { symbol = RouteParameter.Optional, controller = "StockApi" } ); // WebApi Configuration to hook up formatters and message handlers RegisterApis(GlobalConfiguration.Configuration); } public static void RegisterApis(HttpConfiguration config) { // remove default Xml handler var matches = config.Formatters .Where(f = f.SupportedMediaTypes .Where(m = m.MediaType.ToString() == "application/xml" || m.MediaType.ToString() == "text/xml") .Count() 0) .ToList() ; foreach (var match in matches) config.Formatters.Remove(match); } } That LINQ code is quite a mouthful of nested collections, but it does the trick to remove the formatter based on the content type. You can also look for the specific formatter (XmlMediatTypeFormatter) by its type name which is simpler, but it's better to search for the supported types as this will work even if there are other custom formatters added. Once removed, now the browser request results in a JSON response: It's a simple solution to a small debugging task that's made my life easier. Maybe you find it useful too…© Rick Strahl, West Wind Technologies, 2005-2012Posted in Web Api  ASP.NET   Tweet !function(d,s,id){var js,fjs=d.getElementsByTagName(s)[0];if(!d.getElementById(id)){js=d.createElement(s);js.id=id;js.src="//platform.twitter.com/widgets.js";fjs.parentNode.insertBefore(js,fjs);}}(document,"script","twitter-wjs"); (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • Update Metadata and Cover Art in Windows Media Player 12

    - by DigitalGeekery
    If you use Windows Media Player 12 in Windows 7, you may notice some of your media is missing information when displayed in the library. Today we look at how to edit and update metadata and cover art in WMP 12. By default, Windows Media Player will pull metadata, such as the title, artist, album, and cover art from the Internet. If you did not accept that default option during setup, we’ll need to turn the feature on first. Select Tools > Options from the top Menu bar. On the Library tab, ensure that Retrieve additional information form the Internet is checked. Click OK. Editing Metadata Now we’re ready to update some files. Find a media file with incorrect details or cover art. Right-click on the title and select Find album info. This will bring up the Find album information window. Here you’ll see the existing information that Windows Media Player interpreted as correct on the left side. The results of  WMP’s search for the media information are on the right. Click on Artists,  Albums , or Tracks to scroll through the search results and try to find a match. You can also type in new keywords in the Search box and hit enter (or click the Search button) to perform a new search.   If you find a correct match for your media file, click to select it and click Next. You’ll be prompted to confirm your selection, then click Finish. You should now see your media file displayed properly in Windows Media Player. Manually Entering Metadata If your search for the correct media information comes up empty, you can always manually enter the information yourself. On the Find album information window, click Edit under Existing Information. You can edit the existing information in the text boxes or the Genre dropdown box. There are a couple hidden text boxes below. Click next to Contributing Artist or Composer to enter that information.   Choosing Your Own Cover Art If your media file doesn’t pull the proper cover art, or if you simply wish to find a different image, you can add your own. Search online for a suitable image. An ideal size would be around 300 x 300 pixels, give or take. Right-click on the image copy the image. You’ll need to switch to Expanded title (if you haven’t already) to paste the image.   Paste your new image by right-clicking on the current image and select Paste album art. Note: If the image is not suitable size or type, the Paste album art option will not be available. Your new cover art will appear in Windows Media Player.   Even though it is pulled from the Internet, cover art is cached on your computer and will still be available when you are disconnected from the Internet. Are you new to Windows Media Player? If so, check out our article on how to Manage your music with Windows Media Player. Similar Articles Productive Geek Tips Make VLC Player Look like Windows Media Player 11Fixing When Windows Media Player Library Won’t Let You Add FilesMake VLC Player Look like Windows Media Player 10Add Images and Metadata to Windows 7 Media Center Movie LibraryMake VLC Player Look like Winamp 5 (Kinda) TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Awe inspiring, inter-galactic theme (Win 7) Case Study – How to Optimize Popular Wordpress Sites Restore Hidden Updates in Windows 7 & Vista Iceland an Insurance Job? Find Downloads and Add-ins for Outlook Recycle !

    Read the article

  • RegexClean Transformation

    Use the power of regular expressions to cleanse your data right there inside the Data Flow. This transformation includes a full user interface for simple configuration, as well as advanced features such as error output configuration. Two regular expressions are used, a match expression and a replace expression. The transformation is designed around the named capture groups or match groups, and even supports multiple expressions. This allows for rich and complex expressions to be built, all through an easy to reuse transformation where a bespoke Script Component was previously the only alternative. Some simple properties are available for each column selected – Behaviour The two behaviour modes offer similar functionality but with a difference. Replace, replaces tokens with the input, and Emit overwrites the whole string. Cascade Cascade allows you to define multiple expressions, each on a new line. The match expression will be processed into one operation per line, which are then processed in order at run-time. Multiple replace expressions can also be specified, again each on a new line. If there is no corresponding replace expression for a match expression line, then the last replace expression will be used instead. It is common to have multiple match expressions, but only a single replace expression. Match Expression The expression used to define the named capture groups. This is where you can analyse the data, and tag or name elements within it as found by the match expression. Replace Expression The replace determines the final output. It will reference the named groups from the match expression and assembles them into the final output. If you want to use regular expressions to validate data then try the Regular Expression Transformation. Quick Start Guide Select a column. A new output column is created for each selected column; there is no option for in-place replacement of column values. One input column can be used to populate multiple output columns, just select the column again in the lower grid, using the Input Columns drop-down selector. Amend the output column name and size as required. They default to the same as the input column selected. Amend the behaviour as required, the default is Replace. Amend the cascade option as required, the default is true. Finally enter your match and replace regular expressions Quick Sample #1 Parse an email address and extract the user and domain portions. Format as a web address passing the user portion as a URL parameter. This uses two match groups, user and host, which correspond to the text before the @ and after it respectively. Behaviour is Emit, and cascade of false, we only have a single match expression. Match Expression ^(?<user>[^@]+)@(?<host>.+)$ Replace Expression - http://www.${host}?user=${user} Results Sample Input Sample Output [email protected] http://www.adventure-works.com?user=zheng0 The component is provided as an MSI file, however to complete the installation, you will have to add the transformation to the Visual Studio toolbox manually. Right-click the toolbox, and select Choose Items.... Select the SSIS Data Flow Items tab, and then check the RegexClean Transformation from the list. Downloads The RegexClean Transformation is available for both SQL Server 2005 and SQL Server 2008. Please choose the version to match your SQL Server version, or you can install both versions and use them side by side if you have both SQL Server 2005 and SQL Server 2008 installed. RegexClean Transformation for SQL Server 2005 RegexClean Transformation for SQL Server 2008 Version History SQL Server 2005 Version 1.0.0.105 - Public Release (28 Jan 2008) SQL Server 2005 Version 1.0.0.105 - Public Release (28 Jan 2008) Screenshot

    Read the article

  • Stream Media from Windows 7 to XP with VLC Media Player

    - by DigitalGeekery
    So you’ve got yourself a new computer with Windows 7 and you’re itching to take advantage of it’s ability to stream media across your home network. But, the rest of the family is still on Windows XP and you’re not quite ready to shell out the cash for the upgrades. Well, today we’ll show you how to easily stream media from Windows 7 to Windows XP with VLC Media Player. On the host computer running Windows 7, you’ll need to have an account set up with both a username and password. A blank password will not work. The media files will need to be located in a shared folder. Note: If the media files are located within the Public directory, or within the profile of the user account you use to log into the Windows 7 computer, they will be shared automatically. Sharing your Media Folders On your Windows 7 computer, right-click on the folder containing the files you’d like to stream and choose Properties.     On the Sharing Tab of the folder properties, click the Share button. Click OK.   Type or select from the drop down the user account you’ll use to log in, or select “Everyone” to share with all users. Then click Add. You may change the permission level, but only Read permission is required to play the media. Repeat this process for any additional folders you wish to share.    The Windows XP Client Computer Now that we’ve shared our media folders from the Windows 7 computer, we’re ready to play our files on the Windows XP computer. Download and install the VLC Media Player. (See link below) Then open VLC. Click on Media from the and select Open File… Browse your network for the shared folder that contains your media.   You’ll be prompted to log in to the host computer. Provide the credentials for a user on the Windows 7 computer. Click OK.   Select your media file and click Open.    Your media playback will begin momentarily.   This is a nice and easy way to stream media across your home network without upgrading multiple computers to Windows 7.  Plus, VLC is certainly no slouch as a Media Player. It’ll play virtually any video or audio file you can throw at it. Have you already upgraded all your home PCs to Windows 7? Check out our previous article on streaming media between Windows 7 computers on your home network. Download VLC Media Player Similar Articles Productive Geek Tips Fixing When Windows Media Player Library Won’t Let You Add FilesShare Digital Media With Other Computers on a Home Network with Windows 7Enable Media Streaming in Windows Home Server to Windows Media PlayerInstall and Use the VLC Media Player on Ubuntu LinuxInstalling Windows Media Player Plugin for Firefox TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Need Help with Your Home Network? Awesome Lyrics Finder for Winamp & Windows Media Player Download Videos from Hulu Pixels invade Manhattan Convert PDF files to ePub to read on your iPad Hide Your Confidential Files Inside Images

    Read the article

  • SQLAuthority News – Windows Efficiency Tricks and Tips – Personal Technology Tip

    - by pinaldave
    This is the second post in my series about my favorite Technology Tips, and I wanted to focus on my favorite Microsoft product.  Choosing just one topic to cover was too hard, though.  There are so many interesting things I have to share that I am forced to turn this second installment into a five-part post.  My five favorite Windows tips and tricks. 1) You can open multiple applications using the task bar. With the new Windows 7 taskbar, you can start navigating with just one click.  For example, you can launch Word by clicking on the icon on your taskbar, and if you are using multiple different programs at the same time, you can simply click on the icon to return to Word.  However, what if you need to open another Word document, or begin a new one?  Clicking on the Word icon is just going to bring you back to your original program.  Just click on the Word icon again while holding down the shift key, and you’ll open up a new document. 2) Navigate the screen with the touch of a button – and not your mouse button. Yes, we live in a pampered age.  We have access to amazing technology, and it just gets better every year.  But have you ever found yourself wishing that right when you were in the middle of something, you didn’t have to interrupt your work flow be reaching for your mouse to navigate through the screen?  Yes, we have all been guilty of this pampered wish.  But Windows has delivered!  Now you can move your application window using your arrow keys. Lock the window to the left, right hand screen: Win+left Arrow and Win+right Arrow Maximize & minimize: Win+up arrow and Win+down arrow Minimize all items on screen: Win+M Return to your original folder, or browse through all open windows: Alt+up arrow, Alt+Left Arrow, or Alt+right arrow Close down or reopen all windows: win+home 3) Are you one of the few people who still uses Command Prompt? You know who you are, and you aren’t ashamed to still use this option that so many people have forgotten about it.  You can easily access it by holding down the shift key while RIGHT clicking on any folder. 4) Quickly select multiple files without using your mouse. We all know how to select multiple files or folders by Ctrl-clicking or Shift-clicking multiple items.  But all of us have tried this, and then accidentally released Ctrl, only to lose all our precious work.  Now there is a way to select only the files you want through a check box system.  First, go to Windows Explorer, click Organize, and then “Folder and Search Options.”  Go to the View tab, and under advanced settings, you can find a box that says “Use check boxes to select items.”  Once this has been selected, you will be able to hover your mouse over any file and a check box will appear.  This makes selecting multiple, random files quick and easy. 5) Make more out of remote access. If you work anywhere in the tech field, you are probably the go-to for computer help with friends and family, and you know the usefulness of remote access (ok, some of us use this extensively at work, as well, but we all have friends and family who rely on our skills!).  Often it is necessary to restart a computer, which is impossible in remote access as the computer will not show the shutdown menu.  To force the computer to do your wishes, we return to Command Prompt.  Open Command Prompt and type “shutdown /s” for shutdown, or “shutdown /r” for restart. I hope you will find above five tricks which I use in my daily use very important. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQLAuthority News, T SQL, Technology Tagged: Personal Technology

    Read the article

  • View Mobile Websites in Windows with Safari 4 Developer Tools

    - by Matthew Guay
    Want to try out mobile websites designed for the iPhone and other mobile devices on your PC?  Safari 4 for Windows lets you do this easily with their developer tools. By default, Safari will show standard desktop websites.  But by making a simple change, you can switch it to work like Safari Mobile on the iPhone or iPod Touch. Getting Started First make sure you have Safari 4 for Windows installed.  You can download Safari directly (link below) and install it as usual.   Or if you already have another Apple program installed, such as QuickTime or iTunes, then you can install it from Apple Software update.  Simply enter apple software update in the Start menu search box. And then select Safari 4 from the list of new software available.  Click Install to automatically download and install Safari. Accept the license Agreement, and then Safari will automatically install. Once this is finished, Safari will be ready to use. View Mobile Sites in Safari First, we need to enable the developer tools.  Click the gear icon on the toolbar, and select Preferences. Click the Advanced tab, and then check the box that says “Show Develop menu in menu bar”. Once you’ve closed your settings box, click the page icon, select Develop, then User Agent, and then choose one of the Mobile Safari settings.  In our test we chose Mobile Safari 3.1.2 – iPhone. To make your browser emulate a mobile device better, you can hide the bookmarks and tab bar to have a more streamlined interface. Click the Gear icon, and select “Hide Bookmarks Bar”, and then repeat and click “Hide Tab Bar”. You can also shrink your window to be closer to the size of a mobile device screen.  Once you’ve done these things, Safari should look similar to this screenshot.  Here we have loaded Google.com, and you can see it in its iPhone-style interface. Simply enter any website into the address bar, and it will load in its mobile interface if it has one.  Here is Google’s other mobile offerings, right inside Windows. Gmail loads messages with the default iPhone interface. One especially interesting mobile site is Apple’s online iPhone User Guide.  When loaded in Safari with the iPhone setting, it loads with a very nice mobile UI that works just like an iPhone app.  In fact, you can even click and drag to scroll, just like you would with your finger on an iPhone. Conclusion Even if you do not have a Smartphone, you can still preview what websites will look like on them with this trick. Not all sites will work of course, but it’s fun to play around with different sites that have mobile versions. Links: Safari 4 Download Apple iPhone online user guide Similar Articles Productive Geek Tips Make Safari Stop Crashing Every 20 Seconds on Windows VistaCustomize Safari for Windows ToolbarSave Screen Space by Hiding the Bookmarks Toolbar in Safari for WindowsEdit Text in a Webpage with Internet Explorer 8Keep Websites From Using Tiny Fonts in Safari TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Windows Media Player 12: Tweak Video & Sound with Playback Enhancements Own a cell phone, or does a cell phone own you? Make your Joomla & Drupal Sites Mobile with OSMOBI Integrate Twitter and Delicious and Make Life Easier Design Your Web Pages Using the Golden Ratio Worldwide Growth of the Internet

    Read the article

  • Remove Programs from the Open With Menu in Explorer

    - by Matthew Guay
    Would you like to clean up the Open with menu in Windows Explorer?  Here’s how you can remove program entries you don’t want in this menu on any version of Windows. Have you ever accidently opened an mp3 with Notepad, or a zip file with Word?  If so, you’re also likely irritated that these programs now show up in the Open with menu in Windows Explorer every time you select one of those files.  Whenever you open a file type with a particular program, Windows will add an entry for it to the Open with menu.  Usually this is helpful, but it can also clutter up the menu with wrong entries. On our computer, we have tried to open a PDF file with Word and Notepad, neither which can actually view the PDF itself.  Let’s remove these entries.  To do this, we need to remove the registry entries for these programs.  Enter regedit in your Start menu search or in the Run command to open the Registry editor. Backup your registry first just in case, so you can roll-back any changes you make if you accidently delete the wrong value.  Now, browse to the following key: HKEY_CURRENT_USER \Software \Microsoft \Windows \CurrentVersion \ Explorer \FileExts\ Here you’ll see a list of all the file extensions that are registered on your computer. Browse to the file extension you wish to edit, click the white triangle beside it to see the subfolders, and select OpenWithList.  In our test, we want to change the programs associated with PDF files, so we select the OpenWithList folder under .pdf. Notice the names of the programs under the Data column on the right.  Right-click the value for the program you don’t want to see in the Open With menu and select Delete. Click Yes at the prompt to confirm that you want to delete this value. Repeat these steps with all the programs you want to remove from this file type’s Open with menu.  You can go ahead and remove entries from other file types as well if you wish. Once you’ve removed the entries you didn’t want to see, check out the Open with menu in Explorer again.  Now it will be much more streamlined and will only show the programs you want to see. Conclusion This simple trick can help you keep your Open with menu tidy, and only show the programs you want in the list.  It can be irritating to accidently open files in programs that can’t even read them.  This trick works in all versions of Windows, including 2000, XP, Vista, and Windows 7. Similar Articles Productive Geek Tips Remove ISP Text or Corporate Branding from Internet Explorer Title BarRemove the Username From the Start Menu in XPKeep Start Menu From Closing After Opening ApplicationsRemove PartyPoker (Or Other Items) from the Internet Explorer Tools MenuUninstall, Disable, or Delete Internet Explorer 8 from Windows 7 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips All My Movies 5.9 CloudBerry Online Backup 1.5 for Windows Home Server Snagit 10 VMware Workstation 7 OpenDNS Guide Google TV The iPod Revolution Ultimate Boot CD can help when disaster strikes Windows Firewall with Advanced Security – How To Guides Sculptris 1.0, 3D Drawing app

    Read the article

  • Beginner Geek: How to Burn an ISO Image to a Disc

    - by Mysticgeek
    There may be a time when you have an ISO image that you need to burn to a CD or DVD for use in a computer or other device. Today we show you how to do it using ImgBurn, ISO Recorder, and Windows Disc Image Burner in Windows 7. You might need to burn an ISO of an operating system, software app, CD, DVD…etc. It doesn’t matter what the ISO image is, burning an image is a fairly straight-forward process and here we’ll take a look at three free options to accomplish it. Using ImgBurn ImgBurn is an awesome free utility that will create ISO images, allow out burn almost anything, and a lot more. Although there are a lot advanced features available, burning an ISO to disc is easy. Download and install ImgBurn (link below) taking the defaults in the install wizard. The main thing to watch for and uncheck during installation is when it offers the worthless Ask Toolbar. The easiest way to use ImgBurn is to burn an image to disc is pop in a blank disc to the CD/DVD drive, right-click on the ISO file, and select Burn using ImgBurn. ImgBurn opens up with the source and destination fields already filled in. You can leave the default settings, then click the Write button. You’ll notice that the ImgBurn Log screen opens, this is by default and is meant to show error messages you may receive during the writing process.   A successful burn! That is all there is to it…click Ok and close out of ImgBurn. Use ISO Recorder ISO Recorder (link below) is another great utility for burning ISO images to disc. They have a version for XP, Vista, and Windows 7 (32 & 64-bit Versions). Pop your blank disc into your CD/DVD drive and right-click on the ISO image file and select Copy image to CD from the Context Menu. In the next screen the image file path is in the Source Image file field. Under Recorder select the drive with your blank disc, select a recording speed and click Next. You’ll see a progress screen while the data is written to the disc and finalizing… That’s it! Your disc will pop out and you can click Finish to close out of ISO Recorder. Use Windows 7 If You’re using Windows 7, use the built in Windows Disc Image Burner feature to burn ISO images to disc. The process is very straight-forward, and for a full walkthrough on this, check out our article on how to burn an ISO image in Windows 7. Conclusion You don’t need an expensive commercial application to burn an ISO image to disc. Using any one of these free utilities will get the job done quite nicely. Download ImgBurn Download ISO Recorder Similar Articles Productive Geek Tips How to Make a Windows Vista Repair Disk If You Don’t Have OneHow to Create a Windows ISO from a Disc Using ImgBurnEasily Burn Discs With BurnAware Free EditionCreate A Windows Home Server Home Computer Restore DiscWhy is Amarok’s "Burn This Album" Disabled in Ubuntu? TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Google Translate (for animals) Out of 100 Tweeters Roadkill’s Scan Port scans for open ports Out of band Security Update for Internet Explorer 7 Cool Looking Screensavers for Windows If it were only this easy

    Read the article

  • SQL SERVER – Fix: Error : 402 The data types ntext and varchar are incompatible in the equal to operator

    - by pinaldave
    Some errors are very simple to understand but the solution of the same is not easy to figure out. Here is one of the similar errors where it clearly suggests where the problem is but does not tell what is the solution. Additionally, there are multiple solutions so developers often get confused with which one is correct and which one is not correct. Let us first recreate scenario and understand where the problem is. Let us run following USE Tempdb GO CREATE TABLE TestTable (ID INT, MyText NTEXT) GO SELECT ID, MyText FROM TestTable WHERE MyText = 'AnyText' GO DROP TABLE TestTable GO When you run above script it will give you following error. Msg 402, Level 16, State 1, Line 1 The data types ntext and varchar are incompatible in the equal to operator. One of the questions I often receive is that voucher is for sure compatible to equal to operator, then why does this error show up. Well, the answer is much simpler I think we have not understood the error message properly. Please see the image below. The next and varchar are not compatible when compared with each other using equal sign. Now let us change the data type on the right side of the string to nvarchar from varchar. To do that we will put N’ before the string. USE Tempdb GO CREATE TABLE TestTable (ID INT, MyText NTEXT) GO SELECT ID, MyText FROM TestTable WHERE MyText = N'AnyText' GO DROP TABLE TestTable GO When you run above script it will give following error. Msg 402, Level 16, State 1, Line 1 The data types ntext and nvarchar are incompatible in the equal to operator. You can see that error message also suggests that now we are comparing next to nvarchar. Now as we have understood the error properly, let us see various solutions to the above problem. Solution 1: Convert the data types to match with each other using CONVERT function. Change the datatype of the MyText to nvarchar. SELECT ID, MyText FROM TestTable WHERE CONVERT(NVARCHAR(MAX), MyText) = N'AnyText' GO Solution 2: Convert the data type of columns from NTEXT to NVARCHAR(MAX) (TEXT to VARCHAR(MAX) ALTER TABLE TestTable ALTER COLUMN MyText NVARCHAR(MAX) GO Now you can run the original query again and it will work fine. Solution 3: Using LIKE command instead of Equal to command. SELECT ID, MyText FROM TestTable WHERE MyText LIKE 'AnyText' GO Well, any of the three of the solutions will work. Here is my suggestion if you can change the column data type from ntext or text to nvarchar or varchar, you should follow that path as text and ntext datatypes are marked as deprecated. All developers any way to change the deprecated data types in future, it will be a good idea to change them right early. If due to any reason you can not convert the original column use Solution 1 for temporary fix. Solution 3 is the not the best solution and use it as a last option. Did I miss any other method? If yes, please let me know and I will add the solution to original blog post with due credit. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Error Messages, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • SQL SERVER – Installing SQL Server Data Tools and SSRS

    - by Pinal Dave
    This example is from the Beginning SSRS by Kathi Kellenberger. Supporting files are available with a free download from the www.Joes2Pros.com web site. If you have installed SQL Server, but are missing the Data Tools or Reporting Services Double-click the SQL Server 2012 installation media. Click the Installation link on the left to view the Installation options. Click the top link New SQL Server stand-alone installation or add features to an existing installation. Follow the SQL Server Setup wizard until you get to the Installation Type screen. At that screen, select Add features to an existing instance of SQL Server 2012. Click Next to move to the Feature Selection page. Select Reporting Services – Native and SQL Server Data Tools. If the Management Tools have not been installed, go ahead and choose them as well. Continue through the wizard and reboot the computer at the end of the installation if instructed to do so. Configure Reporting Services If you installed Reporting Services during the installation of the SQL Server instance, SSRS will be configured automatically for you. If you install SSRS later, then you will have to go back and configure it as a subsequent step. Click Start > All Programs > Microsoft SQL Server 2012 > Configuration Tools > Reporting Services Configuration Manager > Connect on the Reporting Services Configuration Connection dialog box. On the left-hand side of the Reporting Services Configuration Manager, click Database. Click the Change Database button on the right side of the screen. Select Create a new report server database and click Next. Click through the rest of the wizard accepting the defaults. This wizard creates two databases: ReportServer, used to store report definitions and security, and ReportServerTempDB which is used as scratch space when preparing reports for user requests. Now click Web Service URL on the left-hand side of the Reporting Services Configuration Manager. Click the Apply button to accept the defaults. If the Apply button has been grayed out, move on to the next step. This step sets up the SSRS web service. The web service is the program that runs in the background that communicates between the web page, which you will set up next, and the databases. The final configuration step is to select the Report Manager URL link on the left. Accept the default settings and click Apply. If the Apply button was already grayed out, this means the SSRS was already configured. This step sets up the Report Manager web site where you will publish reports. You may be wondering if you also must install a web server on your computer. SQL Server does not require that the Internet Information Server (IIS), the Microsoft web server, be installed to run Report Manager. Click Exit to dismiss the Reporting Services Configuration Manager dialog box. Tomorrow’s Post Tomorrow’s blog post will show how to create your first report using the Report Wizard. If you want to learn SSRS in easy to simple words – I strongly recommend you to get Beginning SSRS book from Joes 2 Pros. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL Tagged: Reporting Services, SSRS

    Read the article

  • Review: A Quick Look at Reflector

    - by James Michael Hare
    I, like many, was disappointed when I heard that Reflector 7 was not free, and perhaps that’s why I waited so long to try it and just kept using my version 6 (which continues to be free).  But though I resisted for so long, I longed for the better features that were being developed, and began to wonder if I should upgrade.  Thus, I began to look into the features being offered in Reflector 7.5 to see what was new. Multiple Editions Reflector 7.5 comes in three flavors, each building on the features of the previous version: Standard – Contains just the Standalone application ($70) VS – Same as Standard but adds Reflector Object Browser for Visual Studio ($130) VSPro – Same as VS but adds ability to set breakpoints and step into decompiled code ($190) So let’s examine each of these features. The Standalone Application (Standard, VS, VSPro editions) Popping open Reflector 7.5 and looking at the GUI, we see much of the same familiar features, with a few new ones as well: Most notably, the disassembler window now has a tabbed window with navigation buttons.  This makes it much easier to back out of a deep-dive into many layers of decompiled code back to a previous point. Also, there is now an analyzer which can be used to determine dependencies for a given method, property, type, etc. For example, if we select System.Net.Sockets.TcpClient and hit the Analyze button, we’d see a window with the following nodes we could expand: This gives us the ability to see what a given type uses, what uses it, who exposes it, and who instantiates it. Now obviously, for low-level types (like DateTime) this list would be enormous, but this can give a lot of information on how a given type is connected to the larger code ecosystem. One of the other things I like about using Reflector 7.5 is that it does a much better job of displaying iterator blocks than Reflector 6 did. For example, if you were to take a look at the Enumerable.Cast() extension method in System.Linq, and dive into the CastIterator in Reflector 6, you’d see this: But now, in Reflector 7.5, we see the iterator logic much more clearly: This is a big improvement in the quality of their code disassembler and for me was one of the main reasons I decided to take the plunge and get version 7.5. The Reflector Object Browser (VS, VSPro editions) If you have the .NET Reflector VS or VSPro editions, you’ll find you have in Visual Studio a Reflector Object Browser window available where you can select and decompile any assembly right in Visual Studio. For example, if you want to take a peek at how System.Collections.Generic.List<T> works, you can either select List<T> in the Reflector Object Browser, or even simpler just select a usage of it in your code and CTRL + Click to dive in. – And it takes you right to a source window with the decompiled source: Setting Breakpoints and Stepping Into Decompiled Code (VSPro) If you have the VSPro edition, in addition to all the things said above, you also get the additional ability to set breakpoints in this decompiled code and step through it as if it were your own code: This can be a handy feature when you need to see why your code’s use of a BCL or other third-party library isn’t working as you expect. Summary Yes, Reflector is no longer free, and yes, that’s a bit of a bummer. But it always was and still is a very fine tool. If you still have Reflector 6, you aren’t forced to upgrade any longer, but getting the nicer disassembler (especially for iterator blocks) and the handy VS integration is worth at least considering upgrading for.  So I leave it up to you, these are some of the features of Reflector 7.5, what’s your thoughts? Technorati Tags: .NET,Reflector

    Read the article

  • ODI 11g – Oracle Multi Table Insert

    - by David Allan
    With the IKM Oracle Multi Table Insert you can generate Oracle specific DML for inserting into multiple target tables from a single query result – without reprocessing the query or staging its result. When designing this to exploit the IKM you must split the problem into the reusable parts – the select part goes in one interface (I named SELECT_PART), then each target goes in a separate interface (INSERT_SPECIAL and INSERT_REGULAR). So for my statement below… /*INSERT_SPECIAL interface */ insert  all when 1=1 And (INCOME_LEVEL > 250000) then into SCOTT.CUSTOMERS_NEW (ID, NAME, GENDER, BIRTH_DATE, MARITAL_STATUS, INCOME_LEVEL, CREDIT_LIMIT, EMAIL, USER_CREATED, DATE_CREATED, USER_MODIFIED, DATE_MODIFIED) values (ID, NAME, GENDER, BIRTH_DATE, MARITAL_STATUS, INCOME_LEVEL, CREDIT_LIMIT, EMAIL, USER_CREATED, DATE_CREATED, USER_MODIFIED, DATE_MODIFIED) /* INSERT_REGULAR interface */ when 1=1  then into SCOTT.CUSTOMERS_SPECIAL (ID, NAME, GENDER, BIRTH_DATE, MARITAL_STATUS, INCOME_LEVEL, CREDIT_LIMIT, EMAIL, USER_CREATED, DATE_CREATED, USER_MODIFIED, DATE_MODIFIED) values (ID, NAME, GENDER, BIRTH_DATE, MARITAL_STATUS, INCOME_LEVEL, CREDIT_LIMIT, EMAIL, USER_CREATED, DATE_CREATED, USER_MODIFIED, DATE_MODIFIED) /*SELECT*PART interface */ select        CUSTOMERS.EMAIL EMAIL,     CUSTOMERS.CREDIT_LIMIT CREDIT_LIMIT,     UPPER(CUSTOMERS.NAME) NAME,     CUSTOMERS.USER_MODIFIED USER_MODIFIED,     CUSTOMERS.DATE_MODIFIED DATE_MODIFIED,     CUSTOMERS.BIRTH_DATE BIRTH_DATE,     CUSTOMERS.MARITAL_STATUS MARITAL_STATUS,     CUSTOMERS.ID ID,     CUSTOMERS.USER_CREATED USER_CREATED,     CUSTOMERS.GENDER GENDER,     CUSTOMERS.DATE_CREATED DATE_CREATED,     CUSTOMERS.INCOME_LEVEL INCOME_LEVEL from    SCOTT.CUSTOMERS   CUSTOMERS where    (1=1) Firstly I create a SELECT_PART temporary interface for the query to be reused and in the IKM assignment I state that it is defining the query, it is not a target and it should not be executed. Then in my INSERT_SPECIAL interface loading a target with a filter, I set define query to false, then set true for the target table and execute to false. This interface uses the SELECT_PART query definition interface as a source. Finally in my final interface loading another target I set define query to false again, set target table to true and execute to true – this is the go run it indicator! To coordinate the statement construction you will need to create a package with the select and insert statements. With 11g you can now execute the package in simulation mode and preview the generated code including the SQL statements. Hopefully this helps shed some light on how you can leverage the Oracle MTI statement. A similar IKM exists for Teradata. The ODI IKM Teradata Multi Statement supports this multi statement request in 11g, here is an extract from the paper at www.teradata.com/white-papers/born-to-be-parallel-eb3053/ Teradata Database offers an SQL extension called a Multi-Statement Request that allows several distinct SQL statements to be bundled together and sent to the optimizer as if they were one. Teradata Database will attempt to execute these SQL statements in parallel. When this feature is used, any sub-expressions that the different SQL statements have in common will be executed once, and the results shared among them. It works in the same way as the ODI MTI IKM, multiple interfaces orchestrated in a package, each interface contributes some SQL, the last interface in the chain executes the multi statement.

    Read the article

  • SQL SERVER – OVER clause with FIRST _VALUE and LAST_VALUE – Analytic Functions Introduced in SQL Server 2012 – ROWS BETWEEN UNBOUNDED PRECEDING AND UNBOUNDED FOLLOWING

    - by pinaldave
    Yesterday I had discussed two analytical functions FIRST_VALUE and LAST_VALUE. After reading the blog post I received very interesting question. “Don’t you think there is bug in your first example where FIRST_VALUE is remain same but the LAST_VALUE is changing every line. I think the LAST_VALUE should be the highest value in the windows or set of result.” I find this question very interesting because this is very commonly made mistake. No there is no bug in the code. I think what we need is a bit more explanation. Let me attempt that first. Before you do that I suggest you read yesterday’s blog post as this question is related to that blog post. Now let’s have fun following query: USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, FIRST_VALUE(SalesOrderDetailID) OVER (ORDER BY SalesOrderDetailID) FstValue, LAST_VALUE(SalesOrderDetailID) OVER (ORDER BY SalesOrderDetailID) LstValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO The above query will give us the following result: As per the reader’s question the value of the LAST_VALUE function should be always 114 and not increasing as the rows are increased. Let me re-write the above code once again with bit extra T-SQL Syntax. Please pay special attention to the ROW clause which I have added in the above syntax. USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, FIRST_VALUE(SalesOrderDetailID) OVER (ORDER BY SalesOrderDetailID ROWS BETWEEN UNBOUNDED PRECEDING AND CURRENT ROW) FstValue, LAST_VALUE(SalesOrderDetailID) OVER (ORDER BY SalesOrderDetailID ROWS BETWEEN UNBOUNDED PRECEDING AND CURRENT ROW) LstValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO Now once again check the result of the above query. The result of both the query is same because in OVER clause the default ROWS selection is always UNBOUNDED PRECEDING AND CURRENT ROW. If you want the maximum value of the windows with OVER clause you need to change the syntax to UNBOUNDED PRECEDING AND UNBOUNDED FOLLOWING for ROW clause. Now run following query and pay special attention to ROW clause again. USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, FIRST_VALUE(SalesOrderDetailID) OVER (PARTITION BY SalesOrderID ORDER BY SalesOrderDetailID ROWS BETWEEN UNBOUNDED PRECEDING AND UNBOUNDED FOLLOWING) FstValue, LAST_VALUE(SalesOrderDetailID) OVER (PARTITION BY SalesOrderID ORDER BY SalesOrderDetailID ROWS BETWEEN UNBOUNDED PRECEDING AND UNBOUNDED FOLLOWING) LstValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO Here is the resultset of the above query which is what questioner was asking. So in simple word, there is no bug but there is additional syntax needed to add to get your desired answer. The same logic also applies to PARTITION BY clause when used. Here is quick example of how we can further partition the query by SalesOrderDetailID with this new functions. USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, FIRST_VALUE(SalesOrderDetailID) OVER (PARTITION BY SalesOrderID ORDER BY SalesOrderDetailID ROWS BETWEEN UNBOUNDED PRECEDING AND UNBOUNDED FOLLOWING) FstValue, LAST_VALUE(SalesOrderDetailID) OVER (PARTITION BY SalesOrderID ORDER BY SalesOrderDetailID ROWS BETWEEN UNBOUNDED PRECEDING AND UNBOUNDED FOLLOWING) LstValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO Above query will give us windowed resultset on SalesOrderDetailsID as well give us FIRST and LAST value for the windowed resultset. There are lots to discuss for this two functions and we have just explored tip of the iceberg. In future post I will discover it further deep. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Function, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • SQL SERVER – Introduction to LEAD and LAG – Analytic Functions Introduced in SQL Server 2012

    - by pinaldave
    SQL Server 2012 introduces new analytical function LEAD() and LAG(). This functions accesses data from a subsequent row (for lead) and previous row (for lag) in the same result set without the use of a self-join . It will be very difficult to explain this in words so I will attempt small example to explain you this function. Instead of creating new table, I will be using AdventureWorks sample database as most of the developer uses that for experiment. Let us fun following query. USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, LEAD(SalesOrderDetailID) OVER (ORDER BY SalesOrderDetailID ) LeadValue, LAG(SalesOrderDetailID) OVER (ORDER BY SalesOrderDetailID ) LagValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO Above query will give us following result. When we look at above resultset it is very clear that LEAD function gives us value which is going to come in next line and LAG function gives us value which was encountered in previous line. If we have to generate the same result without using this function we will have to use self join. In future blog post we will see the same. Let us explore this function a bit more. This function not only provide previous or next line but it can also access any line before or after using offset. Let us fun following query, where LEAD and LAG function accesses the row with offset of 2. USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, LEAD(SalesOrderDetailID,2) OVER (ORDER BY SalesOrderDetailID ) LeadValue, LAG(SalesOrderDetailID,2) OVER (ORDER BY SalesOrderDetailID ) LagValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO Above query will give us following result. You can see the LEAD and LAG functions  now have interval of  rows when they are returning results. As there is interval of two rows the first two rows in LEAD function and last two rows in LAG function will return NULL value. You can easily replace this NULL Value with any other default value by passing third parameter in LEAD and LAG function. Let us fun following query. USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, LEAD(SalesOrderDetailID,2,0) OVER (ORDER BY SalesOrderDetailID ) LeadValue, LAG(SalesOrderDetailID,2,0) OVER (ORDER BY SalesOrderDetailID ) LagValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO Above query will give us following result, where NULL are now replaced with value 0. Just like any other analytic function we can easily partition this function as well. Let us see the use of PARTITION BY in this clause. USE AdventureWorks GO SELECT s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty, LEAD(SalesOrderDetailID) OVER (PARTITION BY SalesOrderID ORDER BY SalesOrderDetailID ) LeadValue, LAG(SalesOrderDetailID) OVER (PARTITION BY SalesOrderID ORDER BY SalesOrderDetailID ) LagValue FROM Sales.SalesOrderDetail s WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY s.SalesOrderID,s.SalesOrderDetailID,s.OrderQty GO Above query will give us following result, where now the data is partitioned by SalesOrderID and LEAD and LAG functions are returning the appropriate result in that window. As now there are smaller partition in my query, you will see higher presence of NULL. In future blog post we will see how this functions are compared to SELF JOIN. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Function, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Remove Ubuntu or XP from the Windows 7 Boot Menu

    - by Trevor Bekolay
    If you’ve ever used a dual-boot system and then removed one of the operating systems, it can still show up in Windows 7’s boot menu. We’ll show you how to get rid of old entries and speed up the boot process. To edit the boot menu, we will use a program called bcdedit that’s included with Windows 7. There are some third-party graphical applications that will edit the menu, but we prefer to use built-in applications when we can. First, we need to open a command prompt with Administrator privileges. Open the start menu and type cmd into the search box. Right click on the cmd program that shows up, and select Run as administrator. Alternatively, if you’ve disabled the search box, you can find the command prompt in All Programs > Accessories. In the command prompt, type in bcdedit and press enter. A list of the boot menu entries will appear. Find the entry that you would like to delete – in our case, this is the last one, with the description of “Ubuntu”. What we need is the long sequence of characters marked as the identifier. Rather than type it out, we will copy it to be pasted later. Right-click somewhere in the command prompt window and select Mark. By clicking the left mouse button and dragging over the appropriate text, select the identifier for the entry you want to delete, including the left and right curly braces on either end. Press the Enter button. This will copy the text to the clipboard. In the command prompt, type in: bcdedit /delete and then right-click somewhere in the command prompt window and select Paste. Press Enter to input the now completed command. The boot menu entry will now be deleted. Type in bcdedit again to confirm that the offending entry is now gone from the list. If you reboot your machine now, you will notice that the boot menu does not even come up, because there is only one entry in the list (unless you had more than two entries to begin with). You’ve shaved a few seconds off of the boot process! Not to mention the added effort of pressing the enter button. There’s a lot more that you can do with bcdedit, like change the description of boot menu entries, create new entries, and much more. For a list of what you can do with bcdedit, type the following into the Command Window. bcdedit /help While there are third-party GUI solutions for accomplishing the same thing, using this method will save you time by not having to go through the extra steps of installing an extra program. Similar Articles Productive Geek Tips Reinstall Ubuntu Grub Bootloader After Windows Wipes it OutClean Up Ubuntu Grub Boot Menu After UpgradesHow To Switch to Console Mode for Ubuntu VMware GuestSet Windows as Default OS when Dual Booting UbuntuChange the GRUB Menu Timeout on Ubuntu TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips CloudBerry Online Backup 1.5 for Windows Home Server Snagit 10 VMware Workstation 7 Acronis Online Backup AceStock, a Tiny Desktop Quote Monitor Gmail Button Addon (Firefox) Hyperwords addon (Firefox) Backup Outlook 2010 Daily Motivator (Firefox) FetchMp3 Can Download Videos & Convert Them to Mp3

    Read the article

  • Stay on Schedule in Chrome with DayHiker

    - by Matthew Guay
    Do you keep your schedule and tasks in Google Calendar?  Here’s a handy extension for Google Chrome that can keep you on top of your appointments without having to open Google Calendar in another tab. Integrate Google Calendar with Chrome DayHiker is a handy extension for Google Chrome that can help you stay on schedule in your browser.  Desktop applications typically can keep you notified easier with popups or alerts, but webapps require you to visit them to view your information.  DayHiker takes the best of both, and can make your Google Calendar work more like a desktop application. To get started, open the DayHiker page from the Chrome Extensions Gallery (link below), and click Install.  Confirm you wish to install it at the prompt. Now you’ll have a new extension button in your Chrome toolbar.  Click the calendar icon to view your Google Calendar.  You’ll need to be signed into your Google account for your calendar to display; click the key icon to select your account if it doesn’t show your appointments automatically. If you’re signed into multiple Google accounts, such as your public Gmail and a Google Apps account, you can select the calendar you wish and click Continue. Now you can quickly see your upcoming appointments.  Simply hover over the icon to see your upcoming events.  Or, just glance at it to see if there are any appointments coming up, as the indicator icon will change colors to show how long you have until your next appointment. Click the icon to see more information about your appointments. Or, click the Add link to add a new appointment.  If you need to edit the appointment details, click Edit Details and the appointment will open in Google Calendar for you to edit. You can also view and manage your tasks in Google Calendar.  Click the checkmark icon, and then add or check-off tasks directly from the extension pane. You can also set an alarm clock in DayHiker.  Click the green circle icon, and then enter the time for the alarm to go off.  Strangely it will only chime if the extension pane is left open, so if you click anywhere else in the browser or even switch to another program it will not chime.   If you’d like to customize DayHiker’s settings, right-click on it and select Options, or select Options in the Chrome Extensions page.  Here you can customize your badges and the DayHiker icon, or enter a custom domain for your Google Apps Pro calendar.   Conclusion If you rely on Google Calendar to stay on top of your schedule, DayHiker can help you stay scheduled and know what’s coming up.  We wish DayHiker supported multiple calendars so we could combine our Google Apps calendars with our personal Google Calendar, but even still, it is a very useful tool.  Whether you’re a tightly scheduled person or just like to jot down to-dos and keep track of them, this extension will help you do this efficiently with familiar Google tools. Link Download DayHiker from the Chrome Extensions Gallery Similar Articles Productive Geek Tips Configure Disk Defragmenter Schedule in Windows 7 or VistaSchedule Updates for Windows Media CenterOpen Multiple Sites Without Reopening the Menus in FirefoxFind a Website’s Actual Location with Chrome FlagsSubscribe to RSS Feeds in Chrome with a Single Click TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips HippoRemote Pro 2.2 Xobni Plus for Outlook All My Movies 5.9 CloudBerry Online Backup 1.5 for Windows Home Server Dual Boot Ubuntu and Windows 7 What is HTML5? Default Programs Editor – One great tool for Setting Defaults Convert BMP, TIFF, PCX to Vector files with RasterVect Free Identify Fonts using WhatFontis.com Windows 7’s WordPad is Actually Good

    Read the article

  • Would using a self-signed SSL certificate be appropriate in this scenario?

    - by Kevin Y
    Now I realize this topic has been discussed in a few questions before (specifically this one), but I'm still a little confused about the implications of using a self-signed certificate, and how I would be affected by doing so in this case. After reading various sources, I'm still a little confused about the exact details of using one. The biggest problem with a self-signed certificate, is a man-in-the-middle attack. Even if you are 100% sure that you are on the correct website and you completely trust the site (your email server for example), you could have someone intercept the connection and present you with their own self-signed certificate. You would think that you are using a secure connection with your email server but you are really using a secure connection to an attacker's email server. – SSL Shopper So somebody could switch out my self-signed certificate with their own, and I wouldn't be able to detect it? The way this site phrases it, it makes it sound worse to install a self-signed certificate than to leave your site without a certificate at all. Self-signed certificates cannot (by nature) be revoked, which may allow an attacker who has already gained access to monitor and inject data into a connection to spoof an identity if a private key has been compromised. CAs on the other hand have the ability to revoke a compromised certificate if alerted, which prevents its further use. - Wikipedia Does this mean that the only way someone could switch out their own certificate for mine is for them to find out the private key? I suppose this is more secure, but I'm still slightly confused about what exactly results from using a self-signed certificate. Is the only issue that obnoxious security warning that pops up in your browser when directed to the site, or is there more to it? Now in my case, I want to add the an SSL certificate to a minuscule Wordpress blog I run that I don't expect anyone else will read anytime soon; I mainly started it to get into the habit of blogging, and to learn more about the process of administrating a site (ex. what to do in situations like this one). Whenever I go to the login page and there's an HTTP:// instead of HTTPS://, I cringe a little. Submitting my password feels like I'm shouting my password out loud with hundreds of people listening. I don't plan on adding any other authors to the site, so I am the only person who would ever need to login. This isn't a site I'm trying to get page views from, or one that handles e-commerce or any sensitive info like that, simply my username and password to login with. One of the concerns (that I've gathered so far) of a self-signed certificate is that non-technical users might be scared by the security warning, but this would not be an issue in my case. TL;DR: If scaring visitors away isn't a concern (which it isn't in my case), is it acceptable to use a self-signed certificate for the purpose of encrypting my Wordpress blog's password, or are there added security issues I should be aware of? Essentially, I'm wondering whether adding a self-signed certificate will be safer than leaving my login page the way it is now, or if it adds the potential for more security breaches than leaving it sans-SSL.

    Read the article

  • C# 4 Named Parameters for Overload Resolution

    - by Steve Michelotti
    C# 4 is getting a new feature called named parameters. Although this is a stand-alone feature, it is often used in conjunction with optional parameters. Last week when I was giving a presentation on C# 4, I got a question on a scenario regarding overload resolution that I had not considered before which yielded interesting results. Before I describe the scenario, a little background first. Named parameters is a well documented feature that works like this: suppose you have a method defined like this: 1: void DoWork(int num, string message = "Hello") 2: { 3: Console.WriteLine("Inside DoWork() - num: {0}, message: {1}", num, message); 4: } This enables you to call the method with any of these: 1: DoWork(21); 2: DoWork(num: 21); 3: DoWork(21, "abc"); 4: DoWork(num: 21, message: "abc"); and the corresponding results will be: Inside DoWork() - num: 21, message: Hello Inside DoWork() - num: 21, message: Hello Inside DoWork() - num: 21, message: abc Inside DoWork() - num: 21, message: abc This is all pretty straight forward and well-documented. What is slightly more interesting is how resolution is handled with method overloads. Suppose we had a second overload for DoWork() that looked like this: 1: void DoWork(object num) 2: { 3: Console.WriteLine("Inside second overload: " + num); 4: } The first rule applied for method overload resolution in this case is that it looks for the most strongly-type match first.  Hence, since the second overload has System.Object as the parameter rather than Int32, this second overload will never be called for any of the 4 method calls above.  But suppose the method overload looked like this: 1: void DoWork(int num) 2: { 3: Console.WriteLine("Inside second overload: " + num); 4: } In this case, both overloads have the first parameter as Int32 so they both fulfill the first rule equally.  In this case the overload with the optional parameters will be ignored if the parameters are not specified. Therefore, the same 4 method calls from above would result in: Inside second overload: 21 Inside second overload: 21 Inside DoWork() - num: 21, message: abc Inside DoWork() - num: 21, message: abc Even all this is pretty well documented. However, we can now consider the very interesting scenario I was presented with. The question was what happens if you change the parameter name in one of the overloads.  For example, what happens if you change the parameter *name* for the second overload like this: 1: void DoWork(int num2) 2: { 3: Console.WriteLine("Inside second overload: " + num2); 4: } In this case, the first 2 method calls will yield *different* results: 1: DoWork(21); 2: DoWork(num: 21); results in: Inside second overload: 21 Inside DoWork() - num: 21, message: Hello We know the first method call will go to the second overload because of normal method overload resolution rules which ignore the optional parameters.  But for the second call, even though all the same rules apply, the compiler will allow you to specify a named parameter which, in effect, overrides the typical rules and directs the call to the first overload. Keep in mind this would only work if the method overloads had different parameter names for the same types (which in itself is weird). But it is a situation I had not considered before and it is one in which you should be aware of the rules that the C# 4 compiler applies.

    Read the article

< Previous Page | 237 238 239 240 241 242 243 244 245 246 247 248  | Next Page >