Search Results

Search found 7435 results on 298 pages for 'hardware'.

Page 243/298 | < Previous Page | 239 240 241 242 243 244 245 246 247 248 249 250  | Next Page >

  • cisco 2900xl - SNMP - Get mac address of device connected to an interface

    - by ankit
    Hello all, Basically what i want to do is to find out what is the mac address of a device plugged in to an interface on the switch (FastEthernet0/1 for example) reading through the switch documentaion i found out that i can configure snmp trap on it to make it notify of any new mac address the switch detects by using the command snmp-server enable traps mac-notifiction but for some reason my switch does not support this feature. the only options i see are CORE_SWITCH(config)#snmp-server enable traps ? c2900 Enable SNMP c2900 traps cluster Enable Cluster traps config Enable SNMP config traps entity Enable SNMP entity traps hsrp Enable SNMP HSRP traps snmp Enable SNMP traps vlan-membership Enable VLAN Membership traps vtp Enable SNMP VTP traps <cr> so the other way would be for me to run a cronjon on my gateway to poll the switch periodically using snmp to get new mac addresses i have looked everywhere but cant seem to find the OID that would provide me this information. any help i can get would me very much appreciated ! here's the output from "show version" on my switch Cisco Internetwork Operating System Software IOS (tm) C2900XL Software (C2900XL-C3H2S-M), Version 12.0(5.4)WC(1), MAINTENANCE INTERIM SOFTWARE Copyright (c) 1986-2001 by cisco Systems, Inc. Compiled Tue 10-Jul-01 11:52 by devgoyal Image text-base: 0x00003000, data-base: 0x00333CD8 ROM: Bootstrap program is C2900XL boot loader CORE_SWITCH uptime is 1 hour, 24 minutes System returned to ROM by power-on System image file is "flash:c2900XL-c3h2s-mz.120-5.4.WC.1.bin" cisco WS-C2912-XL (PowerPC403GA) processor (revision 0x11) with 8192K/1024K bytes of memory. Processor board ID FAB0409X1WS, with hardware revision 0x01 Last reset from power-on Processor is running Enterprise Edition Software Cluster command switch capable Cluster member switch capable 12 FastEthernet/IEEE 802.3 interface(s) 32K bytes of flash-simulated non-volatile configuration memory. Base ethernet MAC Address: 00:01:42:D0:67:00 Motherboard assembly number: 73-3397-08 Power supply part number: 34-0834-01 Motherboard serial number: FAB040843G4 Power supply serial number: DAB05030HR8 Model revision number: A0 Motherboard revision number: C0 Model number: WS-C2912-XL-EN System serial number: FAB0409X1WS Configuration register is 0xF thanks, -ankit

    Read the article

  • Request bursting from web application Load Tests

    - by MaseBase
    I'm migrating our web and database hosting to a new environment on all new machines. I've recently performed a Load Test using WAPT to generate load from multiple distributed clients. The server has plenty of room to handle the traffic load, but I'm seeing an odd pattern of incoming traffic during the load tests. Here is the gist of our setup: Firewall server running MS Forefront TMG 2010 on Win 2k8 server Request routing done by IIS Application Request Routing on firewall machine Web server is a Hyper-V VM on the Database server (which is the host OS) These machines are hefty with dual-CPU's with six cores (12 total procs) Web server running IIS 7.5 Web applications built in ASP.NET 2.0, with 1 ISAPI filter (Url Rewrite) in front What I'm seeing during the load tests is that the requests all come through in bursts. Even though I have 7 different distributed clients sending traffic loads, the requests come through about 300-500 requests at a time. The performance monitor shows nearly all of the counters moving through this pattern, where a burst of requests comes in the req/sec jumps to 70, the queued requests jumps to 500, the current requests jumps up, the CPU jumps up, everything. Then once it's handled that group of requests, it has a lull for nearly 10 seconds where nearly nothing is happening. 0-5 req/sec, 0 queued requests, minimal CPU usage. Then after 10 seconds of inactivity, another burst comes through, spiking all of the counters once again. What I can't figure out is why the requests are coming through in bursts when I know that the load being generated is not sent that way, especially considering the various load-generating clients sending traffic all in different intervals with random think time's between each request. Is there something in the layers between Hyper-V or perhaps in the hardware which might cause this coalesce of requests together? Here is what i'm looking at, the highlighted metric is Requests/sec, but the others critical counter go with it: Requests Queued (which I'd obviously like to keep as close to 0 as possible). Any ideas on this?

    Read the article

  • Spurious alleged file corruption on Windows 7

    - by Johannes Rössel
    Recently my Laptop sometimes warns about corrupted files on the hard drive (Samsung SSD PB22-JS3 TM). This has only happened so far when updating (or checking out) an SVN repository with either TortoiseSVN or the command line Subversion client. The fun thing is that the corrupted file has always been a .svn directory (although the directory entry may contain files in that directory too, if they're small enough?—?which should be the case with SVN). However, when looking into the warned-about directory I notice nothing strange or unusual and don't get any more warnings about it and another try (SVN stops updating once that error occurs?—?TortoiseSVN even with an appropriate error message) of updating the working copy works (well, mostly; sometimes it does it again, albeit with a different directory). Since the laptop is only a few months old I doubt the SSD is failing already—five months of normal usage shouldn't be too surprising. Also it (so far) occurred only with SVN updates on a large repository. Maybe that's too many writes in a short time and some part between the software and the hardware doesn't quite catch up fast enough or so?—?I don't know enough about this to actually make an informed guess here. Anyone knows what's up here? ETA: Note to add: I've run chkdsk (it seems to schedule itself anyway when this happens) and it didn't find anything out of the ordinary.

    Read the article

  • Using NginX and Apache alongside for both static and dynamic files

    - by faridv
    Background: I've searched a lot and found these useful threads about using of Apache or NginX for static or dynamic files. But they are old (mostly about 1 or 2 years ago) and I think both webservers, specifically Nginx has had important changes in performance and usage. So I think take another look on these issue cannot be that bad. Nginx (for static files) and Apache (for dynamic content)? nginx better than apache for dynamic content? [closed] Apache or NGINX for PHP? Nginx as reverse proxy to Apache with only dynamic content? My question: I have a PHP web application with lots of dynamic files and lots of static contents (videos, images etc.) and it's currently running on a CentOS 6 server and Apache 2.2 since 2 months ago. In past few days, number of our site visitors have gained so fast and I just thought if this number continues to increase with current ratio, we need to change many things (web server, application, etc.) to prevent failures. Because of hardware limitations that we are facing, I thought that it's best for us to start with web server. Should I start with something else? Should I try to increase performance of my PHP application and forget about web server for now? (even if gonna take a long time!) Because of huge usage of .htaccess files (for redirection, rewrites, etc.), I think it's gonna be painful to migrate to NginX as default web server or maybe only for dynamic files. Does this mean that I can't even use Nginx as reverse proxy? I'm not sure latest stable version of NginX and PHP-FPM have a better performance over my current Apache and my limitations (too many things) won't let me to give it a try. Which one is doing better currently? What will I lose by migrating to Nginx? To make it short, what should I do?

    Read the article

  • Is it possible to detect nearby Wi-Fi enabled devices, not necessarily on the same network? [closed]

    - by Sky
    first question on StackExchange ever. I hope I got the right board. I'm trying to create a device (either from a standard AP or some other unconventional means) that will be able to detect nearby Wi-Fi enabled devices. For example, if a cellular phone (iPhone for instance) would be carried into the secured area, its MAC address will be logged. A cellular phone is a good example because it's the most common threat that should be detected. Some important points: The detection can be either active or passive, doesn't matter. The detected device might be connected to a different network, or might not be connected to anything at all. I assume most cellular phones are actively probing when not connected, but I'm not sure. It is important to not only identify the breach, but also to identify the device (MAC address). Conventional hardware is only optional. Distance of detection is at least 6 meters (20 feet). Handling one device at a time is good. Speed of detection is important, under 5 seconds is ideal. So my question is, is this even possible? If so, what can I use in order to make this a reality? Thank you for reading!

    Read the article

  • NAT cause huge External (actually internal) bandwidth usage

    - by user67953
    We have 4 servers running in a data center, with internal IP: 192.168.3.* assigned. A hardware (FORTIGATE) firewall configured NAT, and it will lead the traffic as: external IP: 111.222.333.10 -> 192.168.3.10 www.server1.com 111.222.333.11 -> 192.168.3.11 www.server2.com 111.222.333.12 -> 192.168.3.12 www.server3.com In DNS, we have www.server1.com A 111.222.333.10 Now if I send a lot of data to www.server1.com from www.server2.com, the data will be send through 111.222.333.10 (external IP) and this cause our bandwidth usage huge (expensive!). The work around I have is to add a local host mapping to server2: 192.168.3.10 www.server1.com. That way when send files from server2 to www.server1.com, it will be internal. However, we are having more and more servers, it would be hard to manually add mapping to every server. Just wondering do we have another solution for this? Can we do something in the FORTIGATE firewall? ps. The DNS server being used is public, such as opendns, Google dns etc.

    Read the article

  • Switch Windows 8 from a hybrid MBR/GPT => GPT only on Macbook Pro Retina

    - by Sid
    I used DiskUtility+Bootcamp Wizard to setup my hard drive for Windows 8 (final MSDN). Somewhere in that process, the Apple tools turned my GPT disk into a hybrid MBR/GPT. All my 4 primary MBR partitions are used up, so when I try turning on Bitlocker in Windows 8, it complains about not finding a System drive. I know on Windows 8 the Bitlocker setup tries to create the 200(?)MB system partition if it's missing. However with all 4 partitions filled I suspect it can't create system drive = it can't find it = throws back an error like "BitLocker Setup could not find a target system drive. You may need to manually prepare your drive for BitLocker". I've already tried disabling hibernation, swap file etc. Now I'm thinking that if I were to get rid of the MBR scheme altogether, perhaps I can be alright within the GPT world without MBR's 4 primary partitions limit. So, how can I get rid of the MBR tables on the hybrid scheme in a manner that still leaves Mac OS and Windows 8 in working conditions? Details: Hardware is the MacbookPro Retina. Primary MBR partitions are consumed as follows: EFI partition HFS+ partition (=encrypted, therefore ="Apple_CoreStorage") HFS+ partition (Recovery partition, contains unencrypted Mac bootloader) NTFS partition (Windows8 all-in-one partition) diskutil list output sid-mbpr:~ sid$ diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *251.0 GB disk0 1: EFI 209.7 MB disk0s1 2: Apple_CoreStorage 160.0 GB disk0s2 3: Apple_Boot Recovery HD 650.0 MB disk0s3 4: Microsoft Basic Data Win8 90.1 GB disk0s4 GPT vs MBR addresses sid-mbpr:~ sid$ sudo gptsync /dev/rdisk0 Password: Current GPT partition table: # Start LBA End LBA Type 1 40 409639 EFI System (FAT) 2 409640 312909639 Unknown 3 312909640 314179175 Mac OS X Boot 4 314179584 490233855 Basic Data Current MBR partition table: # A Start LBA End LBA Type 1 1 409639 ee EFI Protective 2 409640 312909639 ac Apple RAID 3 312909640 314179175 ab Mac OS X Boot 4 * 314179584 490233855 07 NTFS/HPFS Status: GPT partition of type 'Unknown' found, will not touch this disk.** **: Ignore this message, the gptsync tool is old and doesn't understand the UUID for "Apple_CoreStorage" / FileVault2 partitions. Since LBA addresses are alright, safe to ignore this message.

    Read the article

  • Windows 7 - Windows XP - sharing - why isn't working?

    - by durumdara
    Hi! This is seems to be "hardware" and not "software" / "programming" question, but I need to use this share in my programs, so it is "close to programming". We had an XP based wireless network. The server is XP Professional, the clients are XP Home (Notebooks). This was working well with folder sharing (with user rights, not simple share). Then we replaced the one of the notebook with Win7/X64 notebook. First time this can reach the server, and the another client too. Later I went to another sites, and connect to another servers, another networks. And then, when I return to this network, I saw that I cannot connect to this server. Nothing of resources I see, and when try to dbl click on this computer, I got login window, where I can write anything, never I can login... The interesting part, that: Another XP home can see the server, can login as quest, or with other user. The server can see the XP home notebook. The Win7 can see the notebook's shared folders, and XP home can see the Win7 shared folders. The server can see the Win7 folders, BUT: the Win7 cannot see the server folders. Cannot see the resources too... The Win7 is in "work networking group", the group name is not mshome. I tried everything on the server, I tried to remove MS client, restore it with simple sharing, set guest password, etc., but I lost the possibilities to access this server from Win7. Does anyone have any idea what I need to see, what I need to set to access these resource - to use them in my programs? Thanks for every info, link: dd

    Read the article

  • Cheapest iSCSI SAN for Windows 2008/SQL Server clustering?

    - by MichaelGG
    Are there any production-quality iSCSI SANs suitable for use with Windows Server 2008/SQL Server for failover clustering? So far, I've only seen Dell's MD3000i, and HP's MSA 2000 (2012i), which both are around $6K with a minimal disk configuration. Buffalo (yea, I know), has a $1000 device with iSCSI support, but they say it will not work for 2008 failover clustering. I'm interested in seeing something suitable for failover in a production environment, but with very low IO requirements. (Clustering, say, a 30GB DB.) As for using software: On Windows, StarWind seems to have a great solution. But it's actually more money than buying a hardware SAN. (As I understand, only the enterprise edition supports having replicas, and that's $3000 a license.) I was thinking I could use Linux, something like DRBD + an iSCSI target would be fine. However, I haven't seen any free or low-cost iSCSI software that supports SCSI-3 persistent reservations, which Windows 2008 needs for failover clustering. I know $6K isn't much at all, just curious to see if there are practical cheaper solutions out there. And finally, yes, the software is expensive, but many small business get MS BizSpark, so the Windows 2008 Enterprise / SQL 2008 licenses are completely free.

    Read the article

  • Why would my HDD main partition suddenly become hidden?

    - by Luis Oscar
    A few days ago I was using my computer as usual and I turned it off. The next day it wouldn't boot up. It just stayed after the hardware diagnostic window on the intermittent underscore screen. So clearly It wasn't booting up. I tried turning it on and off a couple of times with no avail. Finally I used windows 7 disk and it seemed as if there was no HDD. not even the installation would see the HDD. So i thought it was dead, i bought a new one installed it with windows and used a external case with the old HDD. plug it in and still couldn't see it. I finally downloaded a partition program EASUS or something and my HDD was there listed WITHOUT a system letter. I could however explore it and i set it as Unhidden and it came back to life. I could see it normally. I really just wish someone could explain to me what happened here, was it a virus? does it means the HDD is about to die? How can i prevent this or what should I do now? should i stop using this OLD HDD? Thanks

    Read the article

  • Picking a linux compatible motherboard

    - by Chris
    Last time I bought a new computer (I build them myself) I got a motherboard that had really poor linux support for a long time. Specifically the audio. I had to wait months before the kernel supported the on board audio chipset. That is exactly the situation I'm trying to avoid this time around. I have some specific questions about "server motherboards" actually. I looked at a few models of server motherboards by intel, and some random models on newegg. I wasn't able to see much of a difference from regular desktop motherboard other than most had two sockets, and support for much more ram. These boards seem more popular with Linux users. Why? AMD and Intel both have server CPUs as well. Some question, what's the difference? To make this question more concrete, I was looking at this this motherboard. The main questions about it that I can't answer are: Can I get a motherboard without on board raid and audio? I wanted to get a hardware raid controller and a PCI audio card. I thought a server motherboard would be cheaper and not have these "extras", since who wants an audio card on a server? Where can I found out about Linux support for the components on this board? "Intel ICH10R", "Realtek ALC889", "Marvell 88E8056" I'm buying this computer to work as a Linux desktop for a lot of compiling, coding and audio/video work, but I don't want to rule out the possibility of installing windows and playing some games at one point. (even if the last game I got has been sitting in its box unopened for almost a year). Is it a good idea to buy a "server motherboard" and play games on it, or are desktop boards better value for this? The ultimate solution for me would be a motherboard that had GPL divers for onboard LAN, a single CPU socket, lots of PCI express and PCI. USB 3.0, and no fancy hard disk controllers since I'll be getting a separate one.

    Read the article

  • HP Officejet 4500 G510n-z Not Showing up in Remote Desktop (Terminal Services)

    - by Greg_the_Ant
    I installed this printer on a windows XP machine. First using the wireless option, and later using USB. In both cases when I connect to my other computer (also Windows XP) via terminal services and check printers in the local resources tab it does not show up on the remote session. I used to have a Samsung connected to my local computer over USB and and that worked fine over terminal services. Things I tried so far: I did read this page and installed the software fix on both computers: (Printers that use ports that do not begin with...) I installed the minimum HP software install on the remote computer and that didn't help either. I also tried running the add new printer wizard on the remote computer: I selected "local printer attached to this computer" and did not check the "automatically.." option. On the next page of the wizard I can select an option for "use the following port". I see options for TS001 through TS009 there. I'm assuming those are coming from the local machine. I tried clicking each one and then checking "have disk" and pointing it to C:\3be8dc611b11322e8ddf8a67\i386\msxpsdrv.inf 1 but for every single TS00.. port it says "The specified location does not contain information about your hardware." Any help would be greatly appreciated. I'm pretty stuck at this point. 1 C:\3be8dc611b11322e8ddf8a67 is the folder I extracted the HP driver software to after I downloaded it.

    Read the article

  • Keep-Alive header not sent from Tomcat 5.5 http connector?

    - by Codek
    We're currently using a hardware load balancer, which then goes to Apache and that then goes to Tomcat 5.5 via the AJP connector. We've decided to dump apache for various reasons - In our current system it doesnt provide any advantage. However when I look at the headers sent when we do this, the "Keep-Alive: timeout=15 max=96" header doesnt get sent when you use the tomcat http connector Interestingly, i can find no documentiation on "keepalivetimeout" for tomcat5.5, but i can for tomcat6. But neither can i find evidence that tomcat5.5 doesnt support this setting. here's my connector: <Connector port="8090" maxHttpHeaderSize="8192" maxThreads="400" minSpareThreads="150" maxSpareThreads="300" enableLookups="false" connectionTimeout="2" maxKeepAliveRequests="400" disableUploadTimeout="true" /> So; Is there any way I can specify the keepalive timeout if we use the http connector with tomcat 5.5, and force this header entry to be sent? Just to be clear - the exact header entry i see back from the server is this with apache: Keep-Alive: timeout=2, max=100 But nothing from tomcat/coyote. I've looked at this some more, and I dont think the Keep-Alive header entry really matters. The problem seems to be that keep-alives are simply not supported in tomcat 5.5 http connector? They do seem to work in tomcat6 (+java 6). Thanks, Dan

    Read the article

  • Windows Server 2008 R2 DNS - One IP, multiple servers

    - by Blu Dragon
    I need opinions and examples on how to best to accomplish the setup I am looking for. I have a public-facing AD domain server with one public IP address. I have setup an external zone for example.com and I successfully have my own name servers pointing to it at ns0.example.com and ns1.example.com. I also have an internal zone for my private network at home.example.com. I am behind a router with the domain server in the DMZ. I want dev.example.com to be accessible from the outside world over https and to point to internal IP address 192.168.1.78. Likewise, I want www.example.com to be accessible from the outside world and point to internal IP address 192.168.1.79. Both dev and www servers are CentOS 5.6 VMs running inside of Hyper-V on the domain server (bad idea I know but I am limited on hardware atm). What is best way to achieve this? From what I have read and researched on Google, I may need to setup a reverse proxy but I am not sure how well that will work with SSL.

    Read the article

  • Intel Atom overheating in ASUS EEE Box 1501P

    - by Sergey L.
    I have had an ASUS EEE Box 1501P for just a little bit over a year. Of course it breaks 2 months after the warranty runs out. http://www.asus.com/Eee/EeeBox_PC/EeeBox_PC_EB1501P/ I have been using the box as a Home Media Center. Running mostly 24/7 often pausing a video overnight. Since last week the fan started running extremely loud. After some digging I found that the Intel Atom CPU in it is overheating and the built-in sensor is reporting temperatures way over 105°C. This got me worried, so I took the unit apart. Completely vacuumed the heat sink, oiled the fan, but the unit is still showing the same behaviour. After turning it on and just observing the hardware monitor in the BIOS the temperature slowly rises from 40°C to over 95°C in appx 5 min. I am running the newest BIOS and a lightweight Linux OPENELEC OS with XBMC on it. Now I am wondering if it could be a faulty heat sensor in the Atom. Recommended running temperature is up to 85°C, but I have not detected any performance hits when running at the above mentioned 105°C and there seem to be no software faults. How can an Atom with an attached heat sink and a fan running at full capacity even get this hot in the first place at 0 load? Aren't those things designed to generate virtually no heat? Could it be a faulty heat sensor? What shall I try to fix this? I would prefer not to damage the CPU, since it is hard fused into the motherboard and cannot be replaced. I could remove the heat pipe/heat sink, but it is getting hot, so heat is properly transferring from the CPU to the heat pipe, the fan is running at full capacity, is recently oiled and warm air is making it out of the exhaust. Edit: One more note: The North-bridge (or whatever it is called nowadays) is on the same heat pipe.

    Read the article

  • SQL Full-Text indexing not populating

    - by Sam
    Hi, We installed a clustered SQL 2005 installation on windows 2008 and reattached our san drives from another machine and restored to do a migration to new hardware. There have been a few minor issues, but this one has me stuck. Trying to populate Full-Text indexes is not working. I create a basic table with some simple text in a new database and get the same results as old indexes. 2010-09-27 10:30:46.85 spid19s Informational: Full-text Full population initialized for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'). Population sub-tasks: 1. 2010-09-27 10:31:15.36 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001DF. Attempt will be made to reindex it. 2010-09-27 10:31:15.37 spid19s The component 'MSFTE.DLL' reported error while indexing. Component path 'D:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Binn\MSFTE.DLL'. 2010-09-27 10:31:15.37 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001E0. Attempt will be made to reindex it. The rebuild/repopulate procedure finishes, but I get zero rows in the index. The .dll in the message is present and the service accounts have access to this. My FTData also has data in it, so it seems there wouldn't be permission issue on this folder. Application throws this error: “PHP Warning: mssql_query() [function.mssql-query]: message: Full-text catalog 'ikm_PageIndex_FText' is in an unusable state. Drop and re-create this full-text catalog. (severity 16) in E:\Inetpub\knowledgebase_insidemesa\lib\database\mssql.php on line 154” A microsoft discussion is the only post I found which had claimed to fix this - said it was registry related, but then didn't post the fix.

    Read the article

  • Providing access to a Samba server for VPN clients

    - by Kamil Kisiel
    We have some Windows users that connect to our network via VPN from home. They need to be able to connect to our Samba server and access a mapped network drive just as they do as when they are on our LAN. The complication is that VPN clients are placed on a subnet other than our office LAN, and behind a firewall. What's the easiest way for me to allow them to still connect to the network share? The solutions I've currently seen involve setting up a WINS server for name resolution purposes and then tunnelling a bunch of the NetBIOS stuff through the firewall. However that means I'd have to set up the VPN DHCP server to hand out the WINS address, something I'm not even sure is possible on the Cisco hardware we have. I'm thinking there must be an easier way. Should I use an LMHOSTS file? Or just map by IP address? Also, I'm not terribly familiar with Windows networking, so which ports would I need to pass through my firewall in order to get the file sharing through?

    Read the article

  • "The directory name is invalid" when trying to install drivers in Windows 7 via Device Manager

    - by Luke
    First off, this computer is not mine, it's a customer's system. Having said that... The hard drive was moved to a new motherboard, CPU, RAM combo, and booted up fine. Customer puts in driver CD, drivers won't load. He brings it into me. Under Device Manager for Windows 7 x64, I see lots of PCI to PCI bridge, one SMBus Controller, and about 20 Unknown Devices. Greeeeeat... So I start with the SMBus driver directly from the Asus website for the motherboard (P8H77-M Pro). If I install from the setup program, it tells me to reboot, then it starts the install. It gets half way through the setup, then fails (An unknown error occurred. Setup will exit). When I try to point to the folder from Device Manager, it starts copying files for the driver, even presents me with the proper name of the device, but says that an error has occurred there as well: The directory name is invalid. Doing some Googling, I saw that many people had this issue with Vista. K, Vista and 7 are similar, maybe the solutions are the same... But they aren't. I tried: Copying the entire driver folder and setup utility to the Program Files folder and running it / selecting it in DM Downloading another set of drivers in case this one is corrupt Disabling UAC Deleting and recreating the %WINDIR%\TEMP folder Removing all references to previous hardware that I could find, even in Device Manager's hidden mode So far, nothing has worked. A wipe and reload will be out of the question

    Read the article

  • BIOS corrupted? How to proceed? Acer Travelmate 290

    - by dtlussier
    I have a older ACER Travelmate 290 (manufactured in 2002 or 2003), which I recently tried to upgrade to Ubuntu 9.10. After doing the upgrade process it appeared as if I had a problem with my x server configuration, as on the first reboot post-install I heard the Ubuntu startup sound, but had a black screen. I thought I would then reboot again to drop down into text-mode to trouble shoot the x configuration problem. However, when I tried rebooting, something went wrong and since then when I start up the machine I get absolutely nothing except the first hardware check (i.e. HDD light flashes, CD/DVD drive spins, etc.). Other than that the screen remains totally black and I have no HDD or processor activity at all. I have tried restarting it a number of time holding down all kinds of key combinations to try and coax it into the BIOS (if possible) with no luck. I have also tried putting in both a live Linux disc and a Windows install disk without any luck. With a disk in the drive it will spin for a few seconds and then stop. All this has lead me to suspect that the BIOS is somehow corrupt (not sure about the right terminology). I have tried putting a new BIOS image and installer program downloaded from ACER on a USB key to see if it will run when I start up the machine, but no luck. I'm not sure if this method of interacting/updating/flashing the BIOS will work outside of Windows/DOS as both OSs are mentioned kind of ambiguously in the documentation. I have also taken the laptop case apart and inspected the various cards and cannot find any obviously burned out components. I'm not sure how to proceed at this point in terms of components to try, or how to try and load a new BIOS image onto the board. Any advice here would be great, especially from those with experience with this particular line of laptops. Thanks!

    Read the article

  • How do I install a different OS on a Compaq Presario cq56 with preinstalled SuSE 11?

    - by McCoy
    Thing is, I don't have a clue of Linux systems, I usually use WinXP. Bought a notebook with SuSE 11 on it, because I have my XP licence and thought I could install that if I found the chipset drivers for the hardware (which I'm not completely sure I have the right versions of). Then I thought I'd give it a shot with the SuSE, looked nice enough. But I can't get my external hd to work (tried force mount) and the banshee doesn't do anything like playing video. Since that is one of the two main purposes of this notebook, I need to get that to work. Tried downloading VLC player, but that only works with SuSE 11.1 upwards. So I downloaded a SuSE 11.3 and burned the iso. But surprise, no way the notebook would boot from cd. Same with the XP cd (considered setting up a dual boot). And no, I can't get to BIOS to reset to default, either. So I can basically do nothing else than going online with this thing and that's not enough for me (gamer in withdrawal, yikes!). I need at least to get to my firefox profile on the external hd and be able to watch video. Can somebody please help me? I think at this point I'd prefer to install XP and MAYBE the SuSE 11.3 after that. I'm not a native speaker, so please speak plainly, thanks. :) Edit: if this is impossible, could someone please help me with the external hd mount and video playback? Edit: Found out how to boot from cd by now. But still no XP, because I get bluescreen after bluescreen while setup is loading files. I guess it's the missing SATA drivers...

    Read the article

  • Upgrading memory on an IBM Power 710 Express (8231-E2B)

    - by cairnz
    We have a Power 710 Express server that was loaded with 4x4 GB memory on a single riser card. I have replaced the 4 chips with 4x8GB and put in another riser card and loaded it with 4x8GB more for a total of 64GB memory. The firmware is AL730_078. When i power it on, the service processor boots up and i can access the ASMi. From here I can look at "Memory Serial Presence Data" and see that the system in some way detects 8x8 GB. However when i look at Hardware Deconfiguration and specifically Memory Deconfiguration, it is still listed with old values, 16384MB, and claims there are 4x4 chips in the C17 riser. How do i proceed to make the server recognize properly the amount of memory installed? I get a FSPSP04 and B181B50F progress code on booting because (i think) it hasn't been told the memory has changed. It then does not proceed to booting the operating system (VIOS) when turned on. Are there any steps I have overlooked here? Can I do some commands, either on the service processor, or otherwise, to tell the system to configure with the proper amount of memory? PS: This is a stand alone server, not configured with HMC or SDMC.

    Read the article

  • CD-ROM Cant Be Accessed After Installing VMware Tools on VMware Server 2.0.2

    - by Optimal Solutions
    Using VMware Server 2.02, I set up a new VM (Windows XP Pro) applied all of the updates, added Windows addons from the install CD, etc... I got it to a stable point and up through that point I was able to access the CD-ROM drive (E: on my host). What I never did before was install "VMware Tools" and since it claims to give better mouse and video support, I gave it a shot. What it does is it places the install package in a virtual CD-ROM drive. I ran the install, no errors and it wants a reboot. I log back in after reboot and pop in the install CD for Microsoft Office 2003 and I receive the message "Please Insert A Disc Into Drive D:". Drive D: would be the next logical drive after the C: drive where I chose to install the OS. The message box sits there and if I click "Cancel", to return to Windows Explorer, the status bar seems to blink ever 1/2 second - as if its polling for a CD-ROM drive or something. No bangs or exclamations in the Device Manager for any hardware. I had taken a snapshot prior to the VMware Tools install and upon restoring it, the CD-ROM is back. I made copies of two other VMs, installed the VMware Tools on those VMs and both experienced the same issues: Windows 2003 Server and Windows 7 (32-bit). Has anyone seen this issue and know of a fix for this? It would be nice to have the better graphics and better mouse control AND use my CD-ROM drive as well! Thank you.

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • Virtual (ESXi4) Win 2k8 R2 server hangs when adding role(s)

    - by Holocryptic
    I'm trying to provision a 2k8r2 Enterprise server in ESXi4. The OS installation goes fine, VMware tools, adding to domain, updates. All the basic stuff before you start adding Roles and Features. I've had this happen on two attempts already, and I'm not sure where the problem might be. I don't think it's hardware, because I have another 2k8r2 Standard server that's running fine. The only real difference is the install media. The server that's working was installed using a trial ISO and license. The one I'm having problems with is a full MAK installation. When I go to add a Role (the last case was Application Server) it gets all the way to "collecting installation results" before it hangs. CPU utilization in the vSphere client shows little spikes of activity with flatlines inbetween, but the whole console is locked up. The only way to release it is to power off and bring it back up. When you go to look at the added roles after bringing it back up, it shows that it is installed, but I don't trust that something didn't get wedged in all of that. The first install I did was with Thin Disk provisioning. The second attempt was with regular disk provisioning. In both cases 4GB of RAM, 2 vCPUs. VMware host is a HP Proliant DL380 G6, RAID-1 OS, RAID-5 data volume. 12 GB RAM. Has anyone else had this problem, or know where I should start poking around?

    Read the article

  • Poor Write Performance in VM inside Proxmox PVE 2.0

    - by sorsenne
    I am running a PVE 2.0 on a decent Hardware (2 SATA HDDs as RAID1, 12GB RAM, i7 CPU) but the I/O Performance is very poor inside the VM (Ubuntu 11.10 Server). The very same VM was copied to another Server running simply Ubuntu Server with KVM and had better I/O Perf. this is how the HDD is shown in the Guest: ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) ata1.00: ATA-8: ST3000DM001-9YN166, CC49, max UDMA/133 ata1.00: 5860533168 sectors, multi 16: LBA48 NCQ (depth 31/32), AA ata1.00: configured for UDMA/133 scsi 0:0:0:0: Direct-Access ATA ST3000DM001-9YN1 CC49 PQ: 0 ANSI: 5 sd 0:0:0:0: [sda] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) sd 0:0:0:0: [sda] 4096-byte physical blocks sd 0:0:0:0: [sda] Write Protect is off sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA I tested with DD: $ dd bs=1M count=128 if=/dev/zero of=test conv=fdatasync 128+0 records in 128+0 records out 134217728 bytes (134 MB) copied, 19.2222 s, 7.0 MB/s on the Host, this same Test will result with 156 MB/s in average. PS: I am using VirtIO and see no error in dmesg.

    Read the article

< Previous Page | 239 240 241 242 243 244 245 246 247 248 249 250  | Next Page >