Search Results

Search found 8367 results on 335 pages for 'temporal difference'.

Page 258/335 | < Previous Page | 254 255 256 257 258 259 260 261 262 263 264 265  | Next Page >

  • ATI firepro will not detect a second DVI-D monitor

    - by John
    OK so weird issue here. I have previously been running 6 screens off of 3 of the older ATI firepro graphics cards but they had a problem with the heat sink getting too hot and warping the PCB resulting in total failure of the card, to replace my three dead cards I purchased a new-type ATI firepro with the newer heat sink design. I'm only using one at the moment to make sure they've fixed the problem before I waste more money on 2 more cards but this is where things start to get weird. The Firepro's only have one port on them, they connect to two monitors via a splitter cable going from the one port to two DVI connectors for the screens. When I plug two identical monitors in via their DVI inputs not matter what I do windows and Catalyst will only detect one screen. However if I use the VGA input on one of the screens with a VGA - DVI adaptor to plug it in to the card it works fine. This confuses me greatly. I'm currently using the ATI Firepro 2270 Graphics card with identical DELL U2311H screens. I can post the rest of the system spec as well if needed but I wouldn't have thought it would make much difference as it had no problem handling 6 screens before the graphics cards failed. Naturally both catalyst and ATI drivers are the most current version. ATI tech support has been absolutely zero help, they seemed to get stumped as soon as I verified that both screens were plugged in and connected properly. Anyone have any ideas?

    Read the article

  • How to scan multiple pages from a book under Linux?

    - by rumtscho
    I want the process to look like: I choose the correct scan settings (dpi, color depth, etc) I lay the first page on the scanner and trigger the process The scanner scans the page and waits for me to position the next page correctly I confirm that the next page is ready for scanning Repeat the above two steps until I tell the scanner that there are no more pages to come The scanner saves everything into a single PDF. I tried both xsane and gscan2pdf. First problem: they want me to know how many pages will be scanned. This is already a nuisance, but I can do the counting if needed. The main problem is that in step 3, the scanner does not pause. It is probably optimised for being fed loose sheets. The next scan process is triggered automatically as soon as the CCD has returned to the start position. The time the scanner needs to return the CCD is very short and I can't turn the page and position the book properly. Is there a software which can do the scan process in the way I described above, or did I just miss a setting available in xsane or gscan2pdf to make the scanner pause? If it makes any difference, the scanner is an Epson Stylus SX620FW, I run it using the manufacturer-provided driver.

    Read the article

  • How do I increase the buffer size for domain sockets in OS X 10.6

    - by Chas. Owens
    In Linux I have no problem dumping tons of data into a domain socket, but the same code on OS X 10.6.2 blows up after about 65 records. The socket reader code looks like #!/usr/bin/perl use strict; use warnings; use IO::Socket; unlink "foo"; my $sock = IO::Socket::UNIX->new ( Local => 'foo', Type => SOCK_DGRAM, Timeout => 600, ) or die "Could not create socket: $!\n"; while (<$sock>) { chomp; print "[$_]\n"; } And the client code looks like #!/usr/bin/perl use strict; use warnings; use IO::Socket; my $sock = IO::Socket::UNIX->new ( Peer => 'foo', Type => SOCK_DGRAM, Timeout => 600, ) or die "Could not create socket: $!\n"; for my $i (1 .. 1_000_000) { print $sock "$i\n" or die $!; } close $sock; The error message I get is No buffer space available at write.pl line 15.. It seems fairly obvious that there is a difference in the buffer size between Linux and OS X, but I don't know how to set it OS X (or what the possible negative side effects might be).

    Read the article

  • Windows File Access Denied

    - by Tom
    I seem to have a general problem with "access denied on Windows". It manifests itself every time if e.g: My bat file calls a compiler creates a file on disk My bat file renames a file But I also have files downloaded (FireFox) to Windows desktop where Windows is giving me "access denied" if I try delete the file. Tried disable AVG + make exception in AVG resident shield (I have tried checking with Task Manager + Winternals process explorer that it is not process running still running that should cause the locks.) Windows 7. My user account is an administrator. All files are created by same user account. The problem is recent, but some things I first noticed yesterday (when I started calling .bat files again which I have used for many years) I have tried: Starting e.g. Windows Explorer with "run as administrator", but that makes no difference right-click - properties - security and changes permissions/ownership (I also get "access denied" when trying this so this does not help) Here is a ascreenshot if I try change security of a "locked" file. (The problem here is the locking occurs continously every time the file is created) ! If I click on, it states I am not the owner? Which baffles me as I just created it. (Yes, through a .bat file calling executables that create the file. But all running under my administrator user account. Interestingly after having this dialog open, the file somehow sometimes suddenly seem to allow me delete it)

    Read the article

  • Administrative shares in Windows 7 Pro not visible

    - by Chris Tybur
    My desktop machine has a clean install of Windows 7 Professional. For some reason the standard administrative shares Admin$, C$, D$, etc are not visible, either in Computer Management - Shared Folders - Shares or via net share. I also have a laptop with a clean install of Windows 7 Professional, and I can see the admin shares in both places. As such, I can map to \\laptop\c$ from the desktop, but I can't map to \\desktop\c$ from the laptop. I pretty much took the defaults during the Windows 7 installations. I've tried adding LocalAccountTokenFilterPolicy to the registry on the desktop, but that didn't work. On the desktop I've also disabled UAC, turned off Windows firewall, removed it from a homegroup, made sure file and printer sharing is turned on, but nothing has worked. There is some subtle difference between the two machines that I can't seem to find. I'm logging into both machines using a local account that is in the Administrators group. Both accounts have the same name and password. I really don't want to have to create a new share for the desktop's C drive, especially since C$ is visible and working on the laptop and therefore I should be able to make it work on the desktop. Any idea why the admin shares would work on one machine and not another? Or why LocalAccountTokenFilterPolicy would fail?

    Read the article

  • Building vs buying a server for an academic lab [closed]

    - by Roy
    I'm looking for advice on the classic build vs buy question. We need a new linux server to run Matlab computation on in our lab (academic). Matlab parallel computing toolbox licence allows up to 12 local workers so we are aiming at a 12 core server with 4GB memory per core (total of 48gb). The system will have an SSD for the OS and a raid-5 (4x2tb) for data. I looked around and found a (relatively) cheap vendor, Silicon Mechanics, that offers a system to our liking (specs below) for $6732. However, buying the components from newegg cost only $4464! The difference is $2268 which is 50% of the base cost. If buying from a company can be thought of as a sort of insurance, basically my premiums are of 50% of the base cost which to me sounds like a lot. Of course any downtime is bad, but the work is not "mission critical", i.e. if it takes a few days to fix it when it breaks its no the end of the world. If it takes weeks to months then its a problem. If it breaks 2-3 times in 3 years, not too bad. If it breaks every month not good. In term of build experience, I set up a linux cluster in grad school (from existing computers) and I build my home pcs but I never built a server before. The server components I'm thinking about: 1 x SUPERMICRO SYS-7046T-6F 4U Tower Server Barebone Dual LGA 1366 Intel 5520 DDR3 1333/1066/800 ($1,050) 12 x Kingston 4GB 240-Pin DDR3 SDRAM DDR3 1333 (PC3 10600) ECC Unbuffered Server Memory ($420) 2 x Intel Xeon E5645 Westmere-EP 2.4GHz LGA 1366 80W Six-Core ($1,116) 4 x Seagate Constellation ES 2TB 7200 RPM SATA 6.0Gb/s 3.5" ($1,040) 1 x SAMSUNG Internal DVD Writer Black SATA ($20) 1 x Intel 520 Series 2.5" 180GB SATA III MLC SSD $300 1 x LSI LSI00281 PCI-Express 2.0 x8 MD2 Low profile SATA / SAS MegaRAID SAS 9260CV-4i Controller Card, $695

    Read the article

  • explanation of RAM specs, and what do I need for a Gaming rig

    - by ewok
    I am looking into upgrading my custom built PC's RAM. I use the machine mostly for gaming, but I don't really know a ton about RAM, so I wanted to ask a few questions. The research I've done tells me there is a negligible increase in speed for anything above 1600 MHz. is this true or is it worth the extra money to go higher? Other than drawing more power from the PSU, is there any real difference in performance with different voltages (1.5V vs 1.65V)? most of the kits I've found in the 2x4 1600 range have a CAS latency of 9 and timing of 9-9-9-24. For a significant increase in price (usually about 1.5x), I can get either 8 or 7 and lower timing. Is it worth the cost? What I am looking for here is someone to give a good explanation of what the different specs represent, and how that relates to the performance of the machine. Specifically, I'm looking for what specs I need to focus on for a good gaming rig. I am NOT looking for a "buy this, it's the best RAM" without an explanation of why. The information will be much more valuable as it will allow me to make my own informed decision. As they say, give a man a fish, he'll eat for a day. teach a man to fish, and he'll eat for the rest of his life.

    Read the article

  • How do I setup JBoss 5.1.0.GA to run multiple instances?

    - by djangofan
    Does anyone have any experience or advice in setting up multiple JBoss 5.1.x instances on the same machine that has 1 network card? Here is what I did: Installed JBoss 5.1.0.GA into c:\myjboss 1.5. I copied the server/default directory to server/ports-01 and server/ports-02 so they have their own config. did I assume correctly? Ran .\run.bat -c ports-01 Ran .\run.bat -c ports-02 At this point there are 2 instances but the second instance doesn't load correctly because of what is probably a few port conflicts. For example: the http port ends up being 8080 for both instances, which it gets from line #49 in the C:\myjboss\server\all\conf\bindingservice.beans\META-INF\bindings-jboss-beans.xml file. Earlier in the server load it clearly gets the value from line#63 in that same file. I don't know why it gets part of the port config from line #49 and the other part from line#63. Confused. I also tried: .\run.bat -Djboss.service.binding.set=ports-01 -c ports-01 and it made little difference. Any ideas on what I am doing wrong?

    Read the article

  • Apache and Virtual Hosts Problem on OS X

    - by Charles Chadwick
    I recently formatted and installed my iMac. I am running 10.6.5. Prior to this format, I had the default Apache web server up and running with several virtual hosts, and everything ran beautifully. After formatting, I set everything back up again, and now Apache is acting funny. Here is a description of what I have going on. My default root directory for the Apache Web server is pointed to an external hard drive. In my httpd.conf, here is what I have: DocumentRoot "/Storage/Sites" Then a few lines beneath that: <Directory /> Options FollowSymLinks AllowOverride All Order deny,allow Allow from all </Directory> And then beneath that: <Directory "/Storage/Sites"> Options Indexes FollowSymLinks MultiViews AllowOverride All Order allow,deny Allow from All </Directory> At the end of this file, I have commented out the user dir include conf file: Include /private/etc/apache2/extra/httpd-userdir.conf And uncommented the virtual hosts conf file: Include /private/etc/apache2/extra/httpd-vhosts.conf Moving on, I have the following entry in my vhosts file: <VirtualHost *:80> DocumentRoot "/Storage/Sites/mysite" ServerName mysite.dev </VirtualHost> I also have a host record in my /etc/hosts file that points mysite.dev to 127.0.0.1 (I also tried using my router IP, 192.168.1.2). The problem I am coming across is, despite having PHP files in /Storage/Sites/mysite, the server is still looking at /Storage/Sites. I know this because in the DocumentRoot contains a php file with phpinfo() (whereas the index.php file in mysite has different code). I have tried setting up other virtual hosts, but they are still doing the same thing. Also, "NameVirtualHost *:80" is in my vhosts file. I saw as a solution on another thread here. Doesn't seem to make a difference. Any ideas on this? Let me know if this is not enough information.

    Read the article

  • Internet Troubles - PPPoE vs PPPoA?

    - by AkkA
    I have been having some internet troubles at home (ADSL2+ connection in Australia). We get random drop-outs from the authentication connection. It will keep the connection to the DSL service, but we lose authentication and either have to restart the router/modem (its combined, a Belkin one, not sure on model number) or unplug the phone cable, wait about 30 seconds and plug it in again. I've called the ISP (Telstra) a few times, but they only offer limited support when we dont use their supported hardware. Apparently something had happened on their side, they checked the box again (at least it sounded that simple), and told me it would be fine. It wasnt. I've replaced all the filters around the house, but that didnt help either. We do live a little bit away from the exchange (get a sync speed of about 3000/900), so I thought it could be due to line noise but that hasnt helped. Telstra allow both PPPoE and PPPoA connections (which I'm configuring through my router, dont have software on the PC side). I've been running PPPoA the whole time, would it make any difference changing it to PPPoE? If not, are there any other theories as to why we would be experiencing these drop-outs? It has been fine for at least 12 months, then suddenly started about 2 months ago.

    Read the article

  • What's going on with traceroute?

    - by Kevin
    The following is what happens when I run traceroute from a certain location: # traceroute google.com traceroute to google.com (74.125.227.39), 30 hops max, 60 byte packets 1 gateway.local.enactpc.com (10.0.0.1) 0.138 ms 0.101 ms 0.084 ms 2 * * * 3 * * * 4 * * * 5 * * * 6 * * * 7 * * * 8 * * * 9 * * * 10 * * * 11 * * * 12 * * * 13 * * * 14 * * * 15 * * * 16 * * * 17 * * * 18 * * * 19 * * * 20 * * * 21 * * * 22 * * * 23 * * * 24 * * * 25 * * * 26 * * * 27 * * * 28 * * * 29 * * * 30 * * * Absolutely nothing of interest... Now, originally I thought this was just a fact of the location's network set up. (I assume they block pings or something...) However, watch what happens when I use nmap to run a traceroute... # nmap -sP --traceroute google.com Starting Nmap 5.21 ( http://nmap.org ) at 2012-09-25 22:18 CDT Nmap scan report for google.com (74.125.227.40) Host is up (0.034s latency). Hostname google.com resolves to 11 IPs. Only scanned 74.125.227.40 rDNS record for 74.125.227.40: dfw06s06-in-f8.1e100.net TRACEROUTE (using proto 1/icmp) HOP RTT ADDRESS 1 0.19 ms gateway.local.enactpc.com (10.0.0.1) 2 1.93 ms 99-20-92-1.lightspeed.austtx.sbcglobal.net (99.20.92.1) 3 25.61 ms 99-20-92-2.lightspeed.austtx.sbcglobal.net (99.20.92.2) 4 ... 6 7 23.68 ms 12.83.68.137 8 31.30 ms gar23.dlstx.ip.att.net (12.122.85.73) 9 ... 10 31.82 ms 72.14.233.65 11 32.27 ms 209.85.250.77 12 32.98 ms dfw06s06-in-f8.1e100.net (74.125.227.40) Nmap done: 1 IP address (1 host up) scanned in 3.29 seconds When using nmap I get A LOT more results than with traceroute, why? Note, I checked, and the difference in target IP addresses is not related...

    Read the article

  • Freebsd jail for an small company - checklist - what shouldn't forget

    - by cajwine
    Looking for an checklist for an "small company freebsd/jail server". Having pretty common starting point: FreeBSD jail (remote/headless) for the company: public web, email, ftp server, and private (maybe in the future partially public) wiki (foswiki) 4 physical persons, (6 email addresses) + one admin - others will never use ssh) have already done usual hardening on the host side (like pf, sshguard etc). my major components are: dovecot, exim, apache22, proftpd, perl5.14. Looking for an checklist, what I shouldn't forget. My plan: openssl self-signed certificates for exim, dovecot and proftpd (wildcard keys) openssl self-signed certificate for apache (later will go for "trusted-signed" key) My questions are: is is an "good practice" having one pair of wildcard SSL-certificates for many programs? (exim, dovecot, proftpd) - or should I generate one key for each service? should I add all 4 persons as standard (unix) users, or I should go with virtual users? Asking because: have only small count of users, and it is more simple to configure everything (exim, dovecot) for local users ($HOME/Maildir), plus ability to set $HOME/.forward/vacation and etc. is here some (special) things what I should consider? (e.g. maybe, in the future we want setup our own webmail - will make this any difference?) any other recommendation? Thank you, hoping that this question fit into the http://serverfault.com/faq under the: Server and Business Workstation operating systems, hardware, software Operations, maintenance, and monitoring Looking for an checklist, but please explain why you're recommending it. See Good Subjective, Bad Subjective. related: What's your suggested mail server configuration for a FreeBSD server?

    Read the article

  • Erratic WiFi 2.4 GHz channel spikes, what gives?

    - by Francis W. Usher
    Sorry guys, first a gripe about my neighbor's WiFi access point (it is related): they totally hog the center nine 2.4 GHz channels (3-11), centered right at 7! I know the outer regions of the signal don't make as much of a difference, and technically they're running channels 5 & 9. Anyway, their signal is clearly interfering with mine, which is necessarily centered at 3 or 11 to evade their interference. I guess it's somewhat a case of access point envy: they happen to have both a stronger signal and a higher data rate, while occupying twice the band width that I do. Getting to the point, I've noticed that they tend to sit nice and pretty centered at 7, but they definitely auto-select their channel, and I've noticed that the auto-selection algorithm tends to shift towards the higher channels; hence I decided to pick channel 3, and I don't get so many intermittent lag spikes any more. Anyway, the thing that weirded me out was the reason they have to auto-select sometimes: unexplained, powerful (talking order of 0dB here), giant spikes of 2.4 GHz activity in consistent regions of the spectrum. I don't think it's just noise, since my wireless monitoring software is registering a MAC address, a manufacturer, and usually a fairly coherent ascii name... and it seems to be a fairly well-confined signal. But these signals are fairly common, and they do some weird stuff to my signal. So my question is what are these signals? Where are they coming from? Where are they going? Why are they so ridiculously strong? Why don't they ever last very long? Here's an inSSIDer screenshot I took, for your perusal. I am labeled with "me", my greedy neighbor labeled with "neighbor", and the 2 quasar signals are labeled with "WTF?".

    Read the article

  • Why does my microwave kill the Wi-Fi?

    - by Ohlin
    Every time I start the microwave in the kitchen, our home Wi-Fi stops working and all devices lose connection with our router! The kitchen and the Wi-Fi router are in opposite ends of the apartment but devices are being used a little here and there. We've been annoyed by the instability of the Wi-Fi for some time and it wasn't until recently we realized it was correlated to microwave usage. After some testing with having the microwave on and off we could narrow down the problem to only occurring when the router is in b/g/n mode and uses a set channel. If I change to b/g mode or set channel to auto then there is no problem any more...but still! The router is a Zyxel P-661HNU ("802.11n Wireless ADSL2+ 4-port Security Gateway" with latest firmware) and the microwave is made by Neff with an effect of 1000W (if this information might be useful to anyone). There is an "internet connection" light on the router and it doesn't go out when the interruption occurs so I think this is only an internal Wi-Fi issue. Now to my questions: What parts of the Wi-Fi can possibly be affected by the microwave usage? Frequency? Disturbances in the electrical system? How can setting Auto on channels make a difference? I thought the different channels were just some kind of separation system within the same frequency spectrum? Could this be a sign that the microwave is malfunctioning and slowly roasting us all at home? Is there any need to be worried? Since we were able to find router settings that cooperate well with our microwave's demand for attention, this question is mainly out of curiosity. But as most people out there...I just can't help the fact that I need to know how it's possible :-)

    Read the article

  • Over gigabit connection, Teracopy does 31MB/s, but Windows 8 does it at ~109MB per second?

    - by Gaurang
    I got my brain-melting first taste of Gigabit networking today, between my 2011 MacMini and Windows 8 Pro desktop connected via Cat.5e to Linksys WRT320N(sporting dd-WRT). After making sure that the line speed on both systems showed 1Gbps, I proceeded to copying a 2.4GB MP4 from the Mini to the Win 8 desktop (SMB sharing). Although satisfied with the 30-34 MB/s that Teracopy was showing (that was a proper step-up for me from 10 MB/s), I still was curious about this massive difference in the advertised and real-world speed. 2 hours of Google had me believing that there were other factors that resulted in less speed, SMB being one. So just for the sake of doing it, I iPerf'd both the systems and guess what that showed - around 875mbps on both systems! I then stumbled upon this little piece of info after which I turned off Teracopy and copied the same file through Windows 8's regular copier. 109 MB/s. Molten brains :) What exactly is causing this? And can I enable such speeds via Teracopy? I really dig the extra features that Teracopy has, will surely miss them now :D

    Read the article

  • Only tunnel certain applications via OpenVPN

    - by jinjin
    Hi, I've purchased a VPN solution, it works correctly when I have "redirect-gateway def1" in the configuration file (routing all traffic through the VPN). However when I remove that line from the configuration file, I am still able to ping-out of the machine (ping -I tap0), however I cannot ping the IP assigned to the machine (it's a public ip), i get the error: Destination Host Unreachable. I only want to have certain applications sending traffic through the VPN tunnel (eg: ZNC, irssi), all of which i can select which IP they use. However they can't recieve any data, making the tunnel essentially useless to me when disabling redirect-gateway. Any ideas on how to allow specific applications use the tunnel, without of forcing everything to go through it? My configuration file is as follows: dev tap remote #.#.#.# float #.#.#.# port 5129 comp-lzo ifconfig #.#.#.# 255.255.255.128 route-gateway #.#.#.# #redirect-gateway def1 secret key.txt cipher AES-128-CBC The output of ifconfig -a when the tunnel is connected: tap0 Link encap:Ethernet HWaddr 00:ff:47:d3:6d:f3 inet addr:#.#.#.# Bcast:#.#.#.# Mask:255.255.255.255 inet6 addr: <snip> Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:612 errors:0 dropped:0 overruns:0 frame:0 TX packets:35 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:25704 (25.1 KiB) TX bytes:6427 (6.2 KiB) EDIT: the Bcast:#.#.#.# (ifconfig) is different from route-gateway #.#.#.# (openvpn) if that makes any difference.

    Read the article

  • Postfix character encoding?

    - by Camran
    I use Postfix as a mailserver. I have Ubuntu OS. Then I use PHP to send emails. Problem is that none of my emails are encoded properly by a mailsoftware which my VPS provider uses. According to them, the problem lies with me. It is only the name field which isn't encoded properly. For example "Björn" becomes "Björn" in my emails. However, when I echo the $name, it outputs "Björn" which is correct. Also, gmail and hotmail does show it correctly. The strange part is that the "text" (the message itself) is encoded properly. I use the following for sending mail: $headers="MIME-Version: 1.0"."\n"; $headers.="Content-type: text/plain; charset=UTF-8"."\n"; $headers.="From: $name <$email>"."\n"; $name= iconv(mb_detect_encoding($name), "UTF-8//IGNORE//TRANSLIT", $name); //// I HAVE TRIED WITH AND WITHOUT THE LINE ABOVE, NO DIFFERENCE mail($to, '=?UTF-8?B?'.base64_encode($subject).'?=', $text, $headers, '[email protected]'); I have tried with and without the iconv line also, no luck. The last thing I can think of is POSTFIX, could there be a setting for character encoding there? Anybody knows?

    Read the article

  • Terminal emulation has stopped working. Garbage escape chars

    - by oligofren
    To enable me to do some remote administration of our servers I started using a terminal emulation program called TouchTerm Pro on my iPhone. While not the smoothest experience, it has allowed me to leave my computer behind when going out of town, which makes the slightly painful experience worthwhile. As of late, the app unfortunately no longer works. Pressing up and down keys after logging on via ssh gives me garbage like ^[[A and ^[[B. Combinations with Ctrl - like you can see in the video - no longer works either. Writing full command lines and executing by the enter key works though. Being able to search my bash history was the difference between a usable app and endless frustration, so getting it to work is essential. The app has (of course) met its end of life, not getting updated anymore. I am not quite sure, which side (client or server) that has to be "fixed"/hacked to make the control sequences work again. But is there something I can do to make it work as intended? You can see a video of TouchTerm in operation here.

    Read the article

  • why Thinkpad T410s intermittent keyboard death?

    - by patrickmdnet
    I have a Thinkpad T410s running Windows 7 64-bit. I have had it for three months. It has the latest BIOS (1.41) and trackpad drivers. In the last week I have started to notice that the keyboard intermittently stops working. Specifically, keystrokes have no effect, including Fn-F12 (shutdown) and Ctrl-Alt-Del. The LED on the capslock key does not turn on or off. Whatever state the lighted keys (e.g. mute) were in remains. The trackpad and trackpoint work properly, and I can close apps and properly shut down the machine. When I attach a USB keyboard it is recognized, but no keys work. If I run the Lenovo keyboard test, all the keys register properly and the caps lock light works again. When I quit the test app, the caps lock light stops working. If I hit Fn-F12 while the keyboard test is running, it goes into hibernation. When the machine comes back from hibernation, once I exit the keyboard test I again cannot do any input on the keyboard. I'm pretty convinced there is a software or driver problem. I never saw this the first three months I had the laptop. I do not recall installing anything recently. I am sure I've received some Windows security updates. I tried using wired networking instead of wireless - no difference. There doesn't appear to be any inciting event; it usually happens when I am working over ssh. I switched from rxvt+ssh to Putty and the problem still occurs. Any ideas?

    Read the article

  • Package pinning in Debian lenny

    - by bronto
    I need your advice as I don't know if I hit a bug, or I am misunderstanding something. On a Debian Lenny, I am trying to prevent the installation of two particular packages, when they are requested as dependencies fromother packages. I am using the same syntax I successfully used in Squeeze, but with no success at all. On squeeze, the following works as expected: # cat /etc/apt/preferences.d/local-no-pike.pref Package: pike7.6-core Pin: version * Pin-Priority: -1000 If I try to install pike7.6, which depends on pike7.6-core, apt and aptitude refuse to do so. On Lenny, the only difference is that there is no support for "fragments" in /etc/apt/preferences.d, and all preferences must be in the /etc/apt/preferences file. But it's not working. E.g., if the file contains: Package: grub-common Pin: version * Pin-Priority: -1000 apt doesn't stop me from installing grub, which depends on grub-common. I used strace to see if the file is being read, and it is. I was suggested to use some Debug:: options, but they didn't help to pinpoint the problem either. I have google'd a lot with some combinations of "lenny" "prevent" "package" "installation" "pinning" and the like, but nothing nice came out. And of course I read man apt_preferences. What am I missing here?

    Read the article

  • Backup Exec tape rotation guidelines

    - by HannesFostie
    Hi We use Backup Exec to take care of our backups for our data server, exchange server, and one more set of systems. Each of these 3 is being done on a separate "set" of tapes. Our goal is to be able to roll back a full 2 weeks, with 1 full backup each weekend and differential/incremental backups in between (the difference between the two in our case isn't very big, because the employees mostly use a very similar set of files throughout the week). While playing around with the settings on how to achieve this, we set the time for BE to keep the full backup to 14 days, but because we have too much data this would require manual intervention each time to erase a certain tape and use that. What I would like to know is what kind of guidelines, tricks, tips and general "stuff to think about" you keep in mind when designing your backup schedule. The type of backups (full/diff/incr) isn't of that much importance in our case as it's more or less set in stone. Made this community wiki as it's not a very specific question. Thanks in advance!

    Read the article

  • windows 7 turns off itself everyday at about 9am

    - by Radek
    I was given this comp at work and after a week or so this strange thing started to happen in the middle of doing something :-( It turns off itself at about 9.10am every morning Just once a day and it works fine after it had it little nap. it happens both if the comp was on all night or I turned it off before leaving the office. I tried to swapped the memory as I was told that there was an issue with memory. But moving or removing any memory did not make any difference. I am not aware that I would install any program that could cause that. I installed AVG and set it up to do every day scan about 8am + if restart is needed it requires user confirmation. 'The Software Protection service has stopped' few minutes before it turned off itself but it happened also at other times without the computer turned off. I turned off Windows automatic updates as the first thing when I got the comp configuration Windows 7 Ultimate Intel Core2 Quad Q9550 at 2.8GH, 8GB RAM ST31000528AS Barracuda 7200.12 SATA 3Gb/s 1TB Update Below message are logged when I turn the comp on again. Message 1: The previous system shutdown at 9:08:54 AM on ?6/?29/?2010 was unexpected. Message 2: Level:Critical Source: Kernel Power EventID 41 Task Category (63) The system has rebooted without cleanly shutting down first. This error could be caused if the system stopped responding, crashed, or lost power unexpectedly. Log after manual restart Update 2 (task scheduler)

    Read the article

  • How can I remove all drivers and other files related to a USB Mass Storage device?

    - by Bob
    I have a flash drive here that does not work on one OS on computer - let's call it the desktop Windows 7. It works fine on another computer - laptop Windows 7. It also works fine on Windows 8 on the same desktop computer. Other flash drives work fine under desktop Windows 7. So not a hardware issue, not a generic USB Mass Storage driver issue. It's something specific to this drive. On desktop Windows 7, I can connect the drive but no volume comes up under Windows Explorer. Ditto for Disk Management. With diskpart, loading hangs until I unplug the drive, if I replug it and try list disk it hangs again. If I unplug the drive at this point, list disk prints out all attached drives - including the just removed flash drive. The drive consistently appears under Device Manager, but uninstalling the drivers, restarting and reinstalling the drivers (by inserting the drive) only works for the first insertion. After that it fails again. I get the feeling that the driver files are not actually removed, and are corrupted, meaning every reinstall it's the same corrupted drivers being installed. Is there any way to remove these drivers completely? Or perhaps some other setting Windows 7 retains? Formatting the drive through another computer/OS does not help. I've also tried a complete wipe and rebuild of the MBR and single partition. The allocation unit size makes no difference; neither does a NTFS format. This is a relatively small matter, and I would not like to reinstall the entire OS!

    Read the article

  • Capabilities of business and SOHO routers

    - by Q8Y
    I'm currently studying for the CCNA certifications (especially for Cisco routers and configuration). I know that business routers provide more features than SOHO routers, the processing speed and RAM can be enough. Assume I need to connect a number of users through a network (accessing internet, share files, printers, ...). I have a high speed connection to the internet and I already applied QoS. How can I find out how many users such a single (SOHO) router could handle? In my case I'd attach to it multiple switches until I have the number of ports needed. Would everything work well and smoothly with 50 users? What about 300? At which point would I need a business router instead? If I implemented VLAN here, would it make any difference in the performance? When do I really need to use more than one router? (Both SOHO and business) I'm thinking that I may need them only if I want to increase the performance (instead of replacing the existing one) and if I have multiple locations, so in this situation I need to have multiple routers, right? Put differently: Is there is a need to have another router if my business all in one place?

    Read the article

  • Windows Vista Wrong Certificate With SNI

    - by JamesArmes
    I'm setting up SNI on an apache server and I thought things were going well. I have two URLs from different domains that point at the same site. I have one virtual host setup for each with the appropriate certificate for each. One of the certificates is valid but the other is self-signed (waiting on GoDaddy for the real cert). If I test the different URLs in Firefox, Safari and Opera all works well. I get no errors for the URL with the valid certificate and I get a self-signed warning for the other. However, in Internet Explorer 8 and Google Chrome, both URLs return the valid certificate (even if its not valid for the specific site). So for the one site, I get a valid certificate. For the other, I get a warning about the cert being for a different site. I tried switching the order of the vhosts and it made no difference. I know that Chrome and IE both use Window's HTTP stack so I understand why the behavior is the same for the two. What I don't understand is why I'm seeing this behavior.

    Read the article

< Previous Page | 254 255 256 257 258 259 260 261 262 263 264 265  | Next Page >