  • Cheapest iSCSI SAN for Windows 2008/SQL Server clustering?

    - by MichaelGG
    Are there any production-quality iSCSI SANs suitable for use with Windows Server 2008/SQL Server for failover clustering? So far, I've only seen Dell's MD3000i, and HP's MSA 2000 (2012i), which both are around $6K with a minimal disk configuration. Buffalo (yea, I know), has a $1000 device with iSCSI support, but they say it will not work for 2008 failover clustering. I'm interested in seeing something suitable for failover in a production environment, but with very low IO requirements. (Clustering, say, a 30GB DB.) As for using software: On Windows, StarWind seems to have a great solution. But it's actually more money than buying a hardware SAN. (As I understand, only the enterprise edition supports having replicas, and that's $3000 a license.) I was thinking I could use Linux, something like DRBD + an iSCSI target would be fine. However, I haven't seen any free or low-cost iSCSI software that supports SCSI-3 persistent reservations, which Windows 2008 needs for failover clustering. I know $6K isn't much at all, just curious to see if there are practical cheaper solutions out there. And finally, yes, the software is expensive, but many small business get MS BizSpark, so the Windows 2008 Enterprise / SQL 2008 licenses are completely free.

    Read the article

  • Windows 7 - Windows XP - sharing - why isn't working?

    - by durumdara
    Hi! This is seems to be "hardware" and not "software" / "programming" question, but I need to use this share in my programs, so it is "close to programming". We had an XP based wireless network. The server is XP Professional, the clients are XP Home (Notebooks). This was working well with folder sharing (with user rights, not simple share). Then we replaced the one of the notebook with Win7/X64 notebook. First time this can reach the server, and the another client too. Later I went to another sites, and connect to another servers, another networks. And then, when I return to this network, I saw that I cannot connect to this server. Nothing of resources I see, and when try to dbl click on this computer, I got login window, where I can write anything, never I can login... The interesting part, that: Another XP home can see the server, can login as quest, or with other user. The server can see the XP home notebook. The Win7 can see the notebook's shared folders, and XP home can see the Win7 shared folders. The server can see the Win7 folders, BUT: the Win7 cannot see the server folders. Cannot see the resources too... The Win7 is in "work networking group", the group name is not mshome. I tried everything on the server, I tried to remove MS client, restore it with simple sharing, set guest password, etc., but I lost the possibilities to access this server from Win7. Does anyone have any idea what I need to see, what I need to set to access these resource - to use them in my programs? Thanks for every info, link: dd

    Read the article

  • Keep-Alive header not sent from Tomcat 5.5 http connector?

    - by Codek
    We're currently using a hardware load balancer, which then goes to Apache and that then goes to Tomcat 5.5 via the AJP connector. We've decided to dump apache for various reasons - In our current system it doesnt provide any advantage. However when I look at the headers sent when we do this, the "Keep-Alive: timeout=15 max=96" header doesnt get sent when you use the tomcat http connector Interestingly, i can find no documentiation on "keepalivetimeout" for tomcat5.5, but i can for tomcat6. But neither can i find evidence that tomcat5.5 doesnt support this setting. here's my connector: <Connector port="8090" maxHttpHeaderSize="8192" maxThreads="400" minSpareThreads="150" maxSpareThreads="300" enableLookups="false" connectionTimeout="2" maxKeepAliveRequests="400" disableUploadTimeout="true" /> So; Is there any way I can specify the keepalive timeout if we use the http connector with tomcat 5.5, and force this header entry to be sent? Just to be clear - the exact header entry i see back from the server is this with apache: Keep-Alive: timeout=2, max=100 But nothing from tomcat/coyote. I've looked at this some more, and I dont think the Keep-Alive header entry really matters. The problem seems to be that keep-alives are simply not supported in tomcat 5.5 http connector? They do seem to work in tomcat6 (+java 6). Thanks, Dan

    Read the article

  • Intel Atom overheating in ASUS EEE Box 1501P

    - by Sergey L.
    I have had an ASUS EEE Box 1501P for just a little bit over a year. Of course it breaks 2 months after the warranty runs out. http://www.asus.com/Eee/EeeBox_PC/EeeBox_PC_EB1501P/ I have been using the box as a Home Media Center. Running mostly 24/7 often pausing a video overnight. Since last week the fan started running extremely loud. After some digging I found that the Intel Atom CPU in it is overheating and the built-in sensor is reporting temperatures way over 105°C. This got me worried, so I took the unit apart. Completely vacuumed the heat sink, oiled the fan, but the unit is still showing the same behaviour. After turning it on and just observing the hardware monitor in the BIOS the temperature slowly rises from 40°C to over 95°C in appx 5 min. I am running the newest BIOS and a lightweight Linux OPENELEC OS with XBMC on it. Now I am wondering if it could be a faulty heat sensor in the Atom. Recommended running temperature is up to 85°C, but I have not detected any performance hits when running at the above mentioned 105°C and there seem to be no software faults. How can an Atom with an attached heat sink and a fan running at full capacity even get this hot in the first place at 0 load? Aren't those things designed to generate virtually no heat? Could it be a faulty heat sensor? What shall I try to fix this? I would prefer not to damage the CPU, since it is hard fused into the motherboard and cannot be replaced. I could remove the heat pipe/heat sink, but it is getting hot, so heat is properly transferring from the CPU to the heat pipe, the fan is running at full capacity, is recently oiled and warm air is making it out of the exhaust. Edit: One more note: The North-bridge (or whatever it is called nowadays) is on the same heat pipe.

    Read the article

  • SQL Full-Text indexing not populating

    - by Sam
    Hi, We installed a clustered SQL 2005 installation on windows 2008 and reattached our san drives from another machine and restored to do a migration to new hardware. There have been a few minor issues, but this one has me stuck. Trying to populate Full-Text indexes is not working. I create a basic table with some simple text in a new database and get the same results as old indexes. 2010-09-27 10:30:46.85 spid19s Informational: Full-text Full population initialized for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'). Population sub-tasks: 1. 2010-09-27 10:31:15.36 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001DF. Attempt will be made to reindex it. 2010-09-27 10:31:15.37 spid19s The component 'MSFTE.DLL' reported error while indexing. Component path 'D:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Binn\MSFTE.DLL'. 2010-09-27 10:31:15.37 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001E0. Attempt will be made to reindex it. The rebuild/repopulate procedure finishes, but I get zero rows in the index. The .dll in the message is present and the service accounts have access to this. My FTData also has data in it, so it seems there wouldn't be permission issue on this folder. Application throws this error: “PHP Warning: mssql_query() [function.mssql-query]: message: Full-text catalog 'ikm_PageIndex_FText' is in an unusable state. Drop and re-create this full-text catalog. (severity 16) in E:\Inetpub\knowledgebase_insidemesa\lib\database\mssql.php on line 154” A microsoft discussion is the only post I found which had claimed to fix this - said it was registry related, but then didn't post the fix.

    Read the article

  • Picking a linux compatible motherboard

    - by Chris
    Last time I bought a new computer (I build them myself) I got a motherboard that had really poor linux support for a long time. Specifically the audio. I had to wait months before the kernel supported the on board audio chipset. That is exactly the situation I'm trying to avoid this time around. I have some specific questions about "server motherboards" actually. I looked at a few models of server motherboards by intel, and some random models on newegg. I wasn't able to see much of a difference from regular desktop motherboard other than most had two sockets, and support for much more ram. These boards seem more popular with Linux users. Why? AMD and Intel both have server CPUs as well. Some question, what's the difference? To make this question more concrete, I was looking at this this motherboard. The main questions about it that I can't answer are: Can I get a motherboard without on board raid and audio? I wanted to get a hardware raid controller and a PCI audio card. I thought a server motherboard would be cheaper and not have these "extras", since who wants an audio card on a server? Where can I found out about Linux support for the components on this board? "Intel ICH10R", "Realtek ALC889", "Marvell 88E8056" I'm buying this computer to work as a Linux desktop for a lot of compiling, coding and audio/video work, but I don't want to rule out the possibility of installing windows and playing some games at one point. (even if the last game I got has been sitting in its box unopened for almost a year). Is it a good idea to buy a "server motherboard" and play games on it, or are desktop boards better value for this? The ultimate solution for me would be a motherboard that had GPL divers for onboard LAN, a single CPU socket, lots of PCI express and PCI. USB 3.0, and no fancy hard disk controllers since I'll be getting a separate one.

    Read the article

  • BIOS corrupted? How to proceed? Acer Travelmate 290

    - by dtlussier
    I have a older ACER Travelmate 290 (manufactured in 2002 or 2003), which I recently tried to upgrade to Ubuntu 9.10. After doing the upgrade process it appeared as if I had a problem with my x server configuration, as on the first reboot post-install I heard the Ubuntu startup sound, but had a black screen. I thought I would then reboot again to drop down into text-mode to trouble shoot the x configuration problem. However, when I tried rebooting, something went wrong and since then when I start up the machine I get absolutely nothing except the first hardware check (i.e. HDD light flashes, CD/DVD drive spins, etc.). Other than that the screen remains totally black and I have no HDD or processor activity at all. I have tried restarting it a number of time holding down all kinds of key combinations to try and coax it into the BIOS (if possible) with no luck. I have also tried putting in both a live Linux disc and a Windows install disk without any luck. With a disk in the drive it will spin for a few seconds and then stop. All this has lead me to suspect that the BIOS is somehow corrupt (not sure about the right terminology). I have tried putting a new BIOS image and installer program downloaded from ACER on a USB key to see if it will run when I start up the machine, but no luck. I'm not sure if this method of interacting/updating/flashing the BIOS will work outside of Windows/DOS as both OSs are mentioned kind of ambiguously in the documentation. I have also taken the laptop case apart and inspected the various cards and cannot find any obviously burned out components. I'm not sure how to proceed at this point in terms of components to try, or how to try and load a new BIOS image onto the board. Any advice here would be great, especially from those with experience with this particular line of laptops. Thanks!

    Read the article

  • Upgrading memory on an IBM Power 710 Express (8231-E2B)

    - by cairnz
    We have a Power 710 Express server that was loaded with 4x4 GB memory on a single riser card. I have replaced the 4 chips with 4x8GB and put in another riser card and loaded it with 4x8GB more for a total of 64GB memory. The firmware is AL730_078. When i power it on, the service processor boots up and i can access the ASMi. From here I can look at "Memory Serial Presence Data" and see that the system in some way detects 8x8 GB. However when i look at Hardware Deconfiguration and specifically Memory Deconfiguration, it is still listed with old values, 16384MB, and claims there are 4x4 chips in the C17 riser. How do i proceed to make the server recognize properly the amount of memory installed? I get a FSPSP04 and B181B50F progress code on booting because (i think) it hasn't been told the memory has changed. It then does not proceed to booting the operating system (VIOS) when turned on. Are there any steps I have overlooked here? Can I do some commands, either on the service processor, or otherwise, to tell the system to configure with the proper amount of memory? PS: This is a stand alone server, not configured with HMC or SDMC.

    Read the article

  • HP Officejet 4500 G510n-z Not Showing up in Remote Desktop (Terminal Services)

    - by Greg_the_Ant
    I installed this printer on a windows XP machine. First using the wireless option, and later using USB. In both cases when I connect to my other computer (also Windows XP) via terminal services and check printers in the local resources tab it does not show up on the remote session. I used to have a Samsung connected to my local computer over USB and and that worked fine over terminal services. Things I tried so far: I did read this page and installed the software fix on both computers: (Printers that use ports that do not begin with...) I installed the minimum HP software install on the remote computer and that didn't help either. I also tried running the add new printer wizard on the remote computer: I selected "local printer attached to this computer" and did not check the "automatically.." option. On the next page of the wizard I can select an option for "use the following port". I see options for TS001 through TS009 there. I'm assuming those are coming from the local machine. I tried clicking each one and then checking "have disk" and pointing it to C:\3be8dc611b11322e8ddf8a67\i386\msxpsdrv.inf 1 but for every single TS00.. port it says "The specified location does not contain information about your hardware." Any help would be greatly appreciated. I'm pretty stuck at this point. 1 C:\3be8dc611b11322e8ddf8a67 is the folder I extracted the HP driver software to after I downloaded it.

    Read the article

  • Providing access to a Samba server for VPN clients

    - by Kamil Kisiel
    We have some Windows users that connect to our network via VPN from home. They need to be able to connect to our Samba server and access a mapped network drive just as they do as when they are on our LAN. The complication is that VPN clients are placed on a subnet other than our office LAN, and behind a firewall. What's the easiest way for me to allow them to still connect to the network share? The solutions I've currently seen involve setting up a WINS server for name resolution purposes and then tunnelling a bunch of the NetBIOS stuff through the firewall. However that means I'd have to set up the VPN DHCP server to hand out the WINS address, something I'm not even sure is possible on the Cisco hardware we have. I'm thinking there must be an easier way. Should I use an LMHOSTS file? Or just map by IP address? Also, I'm not terribly familiar with Windows networking, so which ports would I need to pass through my firewall in order to get the file sharing through?

    Read the article

  • "The directory name is invalid" when trying to install drivers in Windows 7 via Device Manager

    - by Luke
    First off, this computer is not mine, it's a customer's system. Having said that... The hard drive was moved to a new motherboard, CPU, RAM combo, and booted up fine. Customer puts in driver CD, drivers won't load. He brings it into me. Under Device Manager for Windows 7 x64, I see lots of PCI to PCI bridge, one SMBus Controller, and about 20 Unknown Devices. Greeeeeat... So I start with the SMBus driver directly from the Asus website for the motherboard (P8H77-M Pro). If I install from the setup program, it tells me to reboot, then it starts the install. It gets half way through the setup, then fails (An unknown error occurred. Setup will exit). When I try to point to the folder from Device Manager, it starts copying files for the driver, even presents me with the proper name of the device, but says that an error has occurred there as well: The directory name is invalid. Doing some Googling, I saw that many people had this issue with Vista. K, Vista and 7 are similar, maybe the solutions are the same... But they aren't. I tried: Copying the entire driver folder and setup utility to the Program Files folder and running it / selecting it in DM Downloading another set of drivers in case this one is corrupt Disabling UAC Deleting and recreating the %WINDIR%\TEMP folder Removing all references to previous hardware that I could find, even in Device Manager's hidden mode So far, nothing has worked. A wipe and reload will be out of the question

    Read the article

  • Windows Server 2008 R2 DNS - One IP, multiple servers

    - by Blu Dragon
    I need opinions and examples on how to best to accomplish the setup I am looking for. I have a public-facing AD domain server with one public IP address. I have setup an external zone for example.com and I successfully have my own name servers pointing to it at ns0.example.com and ns1.example.com. I also have an internal zone for my private network at home.example.com. I am behind a router with the domain server in the DMZ. I want dev.example.com to be accessible from the outside world over https and to point to internal IP address 192.168.1.78. Likewise, I want www.example.com to be accessible from the outside world and point to internal IP address 192.168.1.79. Both dev and www servers are CentOS 5.6 VMs running inside of Hyper-V on the domain server (bad idea I know but I am limited on hardware atm). What is best way to achieve this? From what I have read and researched on Google, I may need to setup a reverse proxy but I am not sure how well that will work with SSL.

    Read the article

  • Virtual (ESXi4) Win 2k8 R2 server hangs when adding role(s)

    - by Holocryptic
    I'm trying to provision a 2k8r2 Enterprise server in ESXi4. The OS installation goes fine, VMware tools, adding to domain, updates. All the basic stuff before you start adding Roles and Features. I've had this happen on two attempts already, and I'm not sure where the problem might be. I don't think it's hardware, because I have another 2k8r2 Standard server that's running fine. The only real difference is the install media. The server that's working was installed using a trial ISO and license. The one I'm having problems with is a full MAK installation. When I go to add a Role (the last case was Application Server) it gets all the way to "collecting installation results" before it hangs. CPU utilization in the vSphere client shows little spikes of activity with flatlines inbetween, but the whole console is locked up. The only way to release it is to power off and bring it back up. When you go to look at the added roles after bringing it back up, it shows that it is installed, but I don't trust that something didn't get wedged in all of that. The first install I did was with Thin Disk provisioning. The second attempt was with regular disk provisioning. In both cases 4GB of RAM, 2 vCPUs. VMware host is a HP Proliant DL380 G6, RAID-1 OS, RAID-5 data volume. 12 GB RAM. Has anyone else had this problem, or know where I should start poking around?

    Read the article

  • CD-ROM Cant Be Accessed After Installing VMware Tools on VMware Server 2.0.2

    - by Optimal Solutions
    Using VMware Server 2.02, I set up a new VM (Windows XP Pro) applied all of the updates, added Windows addons from the install CD, etc... I got it to a stable point and up through that point I was able to access the CD-ROM drive (E: on my host). What I never did before was install "VMware Tools" and since it claims to give better mouse and video support, I gave it a shot. What it does is it places the install package in a virtual CD-ROM drive. I ran the install, no errors and it wants a reboot. I log back in after reboot and pop in the install CD for Microsoft Office 2003 and I receive the message "Please Insert A Disc Into Drive D:". Drive D: would be the next logical drive after the C: drive where I chose to install the OS. The message box sits there and if I click "Cancel", to return to Windows Explorer, the status bar seems to blink ever 1/2 second - as if its polling for a CD-ROM drive or something. No bangs or exclamations in the Device Manager for any hardware. I had taken a snapshot prior to the VMware Tools install and upon restoring it, the CD-ROM is back. I made copies of two other VMs, installed the VMware Tools on those VMs and both experienced the same issues: Windows 2003 Server and Windows 7 (32-bit). Has anyone seen this issue and know of a fix for this? It would be nice to have the better graphics and better mouse control AND use my CD-ROM drive as well! Thank you.

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • Audio card with built-in ground isolator?

    - by Dave Jarvis
    What audio cards would you recommend that eliminate hum, and hard-drive & mouse movement signal interference? Hardware components: Motherboard. Asus P5Q SE Audio. Realtek ALC 1200, 8-Channel High-Definition Audio CODEC (on board) Harddrive. WD Caviar 320 GB Mouse. Logitech Marbleman USB Mixer. Mackie d.4 Pro Amplifier. Sonance Sonamp 260 All components are plugged into the same Monster Power HDP 910 powerbar (does not help eliminate noise). I have no other components plugged in. The computer uses a Monster iCable 1000 to go from mini (on board audio) to RCA (mixer). I have moved the cable as far from other cables as possible. A ground loop isolator between the mixer and on board audio eliminates all noise. I would rather not use a ground loop isolator; an internal audio card that is Linux-compatible (Kubuntu) would be ideal. Suggestions?

    Read the article

  • Poor Write Performance in VM inside Proxmox PVE 2.0

    - by sorsenne
    I am running a PVE 2.0 on a decent Hardware (2 SATA HDDs as RAID1, 12GB RAM, i7 CPU) but the I/O Performance is very poor inside the VM (Ubuntu 11.10 Server). The very same VM was copied to another Server running simply Ubuntu Server with KVM and had better I/O Perf. this is how the HDD is shown in the Guest: ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) ata1.00: ATA-8: ST3000DM001-9YN166, CC49, max UDMA/133 ata1.00: 5860533168 sectors, multi 16: LBA48 NCQ (depth 31/32), AA ata1.00: configured for UDMA/133 scsi 0:0:0:0: Direct-Access ATA ST3000DM001-9YN1 CC49 PQ: 0 ANSI: 5 sd 0:0:0:0: [sda] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) sd 0:0:0:0: [sda] 4096-byte physical blocks sd 0:0:0:0: [sda] Write Protect is off sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA I tested with DD: $ dd bs=1M count=128 if=/dev/zero of=test conv=fdatasync 128+0 records in 128+0 records out 134217728 bytes (134 MB) copied, 19.2222 s, 7.0 MB/s on the Host, this same Test will result with 156 MB/s in average. PS: I am using VirtIO and see no error in dmesg.

    Read the article

  • Spurious alleged file corruption with an SSD

    - by Johannes Rössel
    Recently my Laptop sometimes warns about corrupted files on the hard drive (Samsung SSD PB22-JS3 TM). This has only happened so far when updating (or checking out) an SVN repository with either TortoiseSVN or the command line Subversion client. The fun thing is that the corrupted file has always been a .svn directory (although the directory entry may contain files in that directory too, if they're small enough?—?which should be the case with SVN). However, when looking into the warned-about directory I notice nothing strange or unusual and don't get any more warnings about it and another try (SVN stops updating once that error occurs?—?TortoiseSVN even with an appropriate error message) of updating the working copy works (well, mostly; sometimes it does it again, albeit with a different directory). Since the laptop is only a few months old I doubt the SSD is failing already—five months of normal usage shouldn't be too surprising. Also it (so far) occurred only with SVN updates on a large repository. Maybe that's too many writes in a short time and some part between the software and the hardware doesn't quite catch up fast enough or so?—?I don't know enough about this to actually make an informed guess here. Anyone knows what's up here? ETA: Note to add: I've run chkdsk (it seems to schedule itself anyway when this happens) and it didn't find anything out of the ordinary.

    Read the article

  • How can find the USB wireless adapter into the dmesg log file?

    - by AndreaNobili
    I am pretty new in Linux (RaspBian for RaspBerry Pi but I think that there are not difference) and I have to install an USB wireless network adapter (the product is the TP-Link TL-WN725N, this one: http://www.tp-link.it/products/details/?model=TL-WN725N ) Now, I think that this is not automatically recognized by my system because if I execute ifconfig command I obtain the following output: pi@raspberrypi ~ $ ifconfig eth0 Link encap:Ethernet HWaddr b8:27:eb:2a:9f:b0 inet addr:192.168.1.8 Bcast:192.168.1.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:475 errors:0 dropped:0 overruns:0 frame:0 TX packets:424 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:34195 (33.3 KiB) TX bytes:89578 (87.4 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) So now it see only my ethernet network interface and not the wireless. So I was thinkig to try to see into the dmesg, but I don't know what have I to see and how to select it into the dmesg output. For example by the following command I can see the line of the dmesg log file relate to my ethernet port: pi@raspberrypi ~ $ cat /var/log/dmesg |grep -i eth [ 3.177620] smsc95xx 1-1.1:1.0 eth0: register 'smsc95xx' at usb-bcm2708_usb-1.1, smsc95xx USB 2.0 Ethernet, b8:27:eb:2a:9f:b0 [ 18.030389] smsc95xx 1-1.1:1.0 eth0: hardware isn't capable of remote wakeup [ 19.642167] smsc95xx 1-1.1:1.0 eth0: link up, 100Mbps, full-duplex, lpa 0x45E1 But what can I try to search for the USB wireless adapter? Tnx

    Read the article

  • Computer turns off unexpectedly

    - by Shahar
    My computer turns itself off unexpectedly after some time of use. It appears that this might be temperature related, but not for sure. I installed 2 tools that monitor temperature: SpeedFan and CPU Thermometer. The only definite finding is that there is a sensor (labelled temp1 in SpeedFan and CPU in CPU thermometer), which shows a temperature of 108C a second before the computer powers down. Until that moment, this sensor shows a constant temperature of 40C. I can usually reproduce the shutdown by viewing a few movies together, which cause another sensor (labelled CPU in SpeedFan) to go up to 60sC, but I do experience the problem even at times when this sensor remains low and cool. It does seem that the problem is more frequent if the computer is turned back on immediately after shutdown, but not always. I have had other hardware problems recently, which might be related: My hard disk heated up. I installed a fan on it, which worked to reduce the heat. The hard disk sensor shows around 40C. I had occasional blue screens and hard disk failures. Replacing the power supply seems to solve both these issues, but then this powerdown problem began appearing. I would appreciate any suggestions as to how to determine where the fault is, or what needs to be replaced.

    Read the article

  • New router messed up server 2003 setup...

    - by Aceth
    Hey, We were sent a new 2wire router today configured it as best we can to match the old bt voyager. We've also got X static IP's. We've manage to get our webserver on one of the new IP's public facing. then we use a hardware firewall which is in a DMZ again with a different static IP. This firewall then is our gateway for our internal LAN. with a few servers etc. The problem we're having is only our PDC (primary Domain controller which has exchange 2003 on) can't ping externally even an external IP. We've connected laptops to the 2wire router and obtain a private ip 192.168.1.X and it works fine can ping etc. our other servers with an internal ip behind the firewall can ping out fine. We've connected to the firewalls logging console and the pings from the server are allowed through so its fine there. The server in question is a Windows server 2003 R2 Enterprise SP2 + Exchange 2003 Server doesn't have firewall turned on. it has static private IP .. gateway is pointing to the right one External Static IP is routing fine inwards We've ran out of ideas .. help??

    Read the article

  • Best practices for settings for Oracle database creation

    - by Gary
    When installing an Oracle Database, what non-default settings would you normally apply (or consider applying) ? I'm not after hardware dependent setting (eg memory allocation) or file locations, but more general items. Similarly anything that is a particular requirement for a specific application rather than generally applicable isn't really useful. Do you separate out code/API schemas (PL/SQL owners) from data schemes (table owners) ? Do you use default or non-default roles, and if the latter, do you password protect the role ? I'm also interested in whether there's any places where you do a REVOKE of a GRANT that is installed by default. That may be version dependent as 11g seems more locked down for its default install. These are ones I used in a recent setup. I'd like to know whether I missed anything or where you disagree (and why). Database Parameters Auditing (AUDIT_TRAIL to DB and AUDIT_SYS_OPERATIONS to YES) DB_BLOCK_CHECKSUM and DB_BLOCK_CHECKING (both to FULL) GLOBAL_NAMES to true OPEN_LINKS to 0 (did not expect them to be used in this environment) Character set - AL32UTF8 Profiles I created an amended password verify function that used the apex dictionary table (FLOWS_030000.wwv_flow_dictionary$) as an extra check to prevent simple passwords. Developer logins CREATE PROFILE profile_dev LIMIT FAILED_LOGIN_ATTEMPTS 8 PASSWORD_LIFE_TIME 32 PASSWORD_REUSE_TIME 366 PASSWORD_REUSE_MAX 12 PASSWORD_LOCK_TIME 6 PASSWORD_GRACE_TIME 8 PASSWORD_VERIFY_FUNCTION verify_function_11g SESSIONS_PER_USER unlimited CPU_PER_SESSION unlimited CPU_PER_CALL unlimited PRIVATE_SGA unlimited CONNECT_TIME 1080 IDLE_TIME 180 LOGICAL_READS_PER_SESSION unlimited LOGICAL_READS_PER_CALL unlimited; Application login CREATE PROFILE profile_app LIMIT FAILED_LOGIN_ATTEMPTS 3 PASSWORD_LIFE_TIME 999 PASSWORD_REUSE_TIME 999 PASSWORD_REUSE_MAX 1 PASSWORD_LOCK_TIME 999 PASSWORD_GRACE_TIME 999 PASSWORD_VERIFY_FUNCTION verify_function_11g SESSIONS_PER_USER unlimited CPU_PER_SESSION unlimited CPU_PER_CALL unlimited PRIVATE_SGA unlimited CONNECT_TIME unlimited IDLE_TIME unlimited LOGICAL_READS_PER_SESSION unlimited LOGICAL_READS_PER_CALL unlimited; Privileges for a standard schema owner account CREATE CLUSTER CREATE TYPE CREATE TABLE CREATE VIEW CREATE PROCEDURE CREATE JOB CREATE MATERIALIZED VIEW CREATE SEQUENCE CREATE SYNONYM CREATE TRIGGER

    Read the article

  • VMware Workstation reboot 32-bit host when starting 64-bit guest

    - by Powerman
    I'm trying to start 64-bit guest (MacOSX and Windows7) on 32-bit host (Hardened Gentoo Linux, kernel 2.6.28-hardened-r9) using VMware Workstation (6.5.3.185404 and 7.0.1.227600). If VT-X disabled in BIOS, VMware refuse to start 64-bit guest (as expected). If VT-X enabled in BIOS, VMware start guest without complaining, but then, in about a second (I suppose as soon as guest try to switch on 64-bit) my host reboots (actually, it's more like reset - normal reboot procedure skipped and BIOS POST start immediately). My hardware is Core 2 Duo 6600 on ASUS P5B-Deluxe with latest stable BIOS 1101. I've power-cycled system, then enabled Vanderpool in BIOS. My CPU doesn't support Trusted Execution Technology, and there no way to disable it in BIOS. I've rebooted several times after that, sometimes with power-cycled, and ensure Vandertool is enabled in BIOS. I've also run VMware-guest64check-5.5.0-18463 tool, and it report "This host is capable of running a 64-bit guest operating system under this VMware product.". About a year ago I tried to disable hardened in kernel to ensure this isn't because of PaX/GrSecurity, but that doesn't help. I have not checked 32-bit guests with VT-X enabled yet, but without VT-X they works ok. ASUS provide "beta" BIOS updates, but according to their descriptions these updates doesn't fix this issue, so I'm not sure is it good idea to try it. My best guess now it's motherboard/BIOS bug. Any ideas?

    Read the article

  • How do I install a different OS on a Compaq Presario cq56 with preinstalled SuSE 11?

    - by McCoy
    Thing is, I don't have a clue of Linux systems, I usually use WinXP. Bought a notebook with SuSE 11 on it, because I have my XP licence and thought I could install that if I found the chipset drivers for the hardware (which I'm not completely sure I have the right versions of). Then I thought I'd give it a shot with the SuSE, looked nice enough. But I can't get my external hd to work (tried force mount) and the banshee doesn't do anything like playing video. Since that is one of the two main purposes of this notebook, I need to get that to work. Tried downloading VLC player, but that only works with SuSE 11.1 upwards. So I downloaded a SuSE 11.3 and burned the iso. But surprise, no way the notebook would boot from cd. Same with the XP cd (considered setting up a dual boot). And no, I can't get to BIOS to reset to default, either. So I can basically do nothing else than going online with this thing and that's not enough for me (gamer in withdrawal, yikes!). I need at least to get to my firefox profile on the external hd and be able to watch video. Can somebody please help me? I think at this point I'd prefer to install XP and MAYBE the SuSE 11.3 after that. I'm not a native speaker, so please speak plainly, thanks. :) Edit: if this is impossible, could someone please help me with the external hd mount and video playback? Edit: Found out how to boot from cd by now. But still no XP, because I get bluescreen after bluescreen while setup is loading files. I guess it's the missing SATA drivers...

    Read the article

  • Windows XP mounting USB drive to same letter as previously mapped network drive

    - by GAThrawn
    Why does Windows always mount a USB drive as the next drive letter after the last physical drive, even when that letter is already taken by a mapped drive, and is there any way to improve this behaviour? What happens is I tend to use a few different flash drives on my PC, as well as having both a Blackberry and a personal phone that mount as USB drives when I plug them in to charge. Being on a corporate PC I also have a number of mapped network drives (some set by login script, some set as persistent mappings in my profile). When I first login I'll have drive letters like this: C: - Local Drive D: - DVD Drive G: - Login script mapped drive J: - Login script mapped drive When I plug the Blackberry in it'll mount two drives (one for onboard storage, one for the SD card) as E: and F:. If I then plug in another USB drive it will mount as G:, even though that's already taken by a network mapped drive. This leaves me with the following drives: C: - Local Drive D: - DVD Drive E: - USB drive (Blackberry) F: - USB drive (Blackberry) G: - Login script mapped drive [G: - USB drive - mounted but not visible in Explorer or command prompt] J: - Login script mapped drive I then have to go into Disk Management, find the new USB drive that's mounted to G: and re-assign it to another letter eg Z:, once this is done Auto-Play detects it and throws up its normal dialog, and its browseable in Explorer. While this is OK to do if you only use one or two USB drives and have admin access to your PC with your login account, its a total pain in the proverbial if you regularly use a whole load of different USB devices, and corporate policy means you have one account for your normal login (that only has User access to workstations), but have to use a different account for any privileged action. I realize that one possible reason for this is the difference between hardware which is mounted and assigned drive letters at the systen level, and mapped drives which are done at the user level. For USB devices that are already plugged in before login, then obviously they're mounted before Windows knows what network drives may be mapped. However if you plug the USB devices in after you're fully logged in and have drives mapped then Windows must know which letters are available?

    Read the article