Search Results

Search found 48592 results on 1944 pages for 'cannot start'.

Page 294/1944 | < Previous Page | 290 291 292 293 294 295 296 297 298 299 300 301  | Next Page >

  • configure monit on linux to monitor a process and then reboot

    - by Elad Dotan
    I would like monit to monitor my service and once it's stopped then I want the computer to reboot. The process don't have a certain port that I can monitor. This is what I did: check process chat with pidfile /var/run/chat.pid start program = "/etc/init.d/chat start" stop program = "/etc/init.d/chat stop" if changed ppid then exec /sbin/reboot I tried all sort of things but it only restart my service. Any suggestion.

    Read the article

  • How would one use Cocos2d to create a game like this.

    - by John Stewart
    http://itunes.apple.com/us/app/angry-birds/id343200656?mt=8&ign-mpt=uo%3D6 So I am getting started with this all game dev thing on iphone and I decided that I will start playing with Cocos2d as my starting engine. Now just so i have a goal in mind, I picked angry birds as my initial target of what sort of game play would I like to learn to build. This is not going to be a market release game. This is totally going to be learning purposes only. So to start off my question is: Would something like this be achievable using Cocos2d? How would I go about building the physics for this? How can one do a screen scroll like the way they do in cocos2d? (any example code would be great) This is just to start off. If you have any particular questions please do add to this question.

    Read the article

  • List service and services status under Win-7

    - by Ronaldo Junior
    I have a service monitor app that monitors the status of three other servers app - you know those kind of green, red status stuff, start, stop, etc. The problem is that it shows the wrong state in Windows 7 even if the user is the administrator. The start, stop buttons are disabled and the install button enabled, the status color is grey which is also wrong. The start button should be enabled with the service status showing green - the apps are running. If the application is run with the setting "run as administrator" then it behaves normally. The application is written in Delphi 7 and works perfectly in other versions of Windows. This line of code: OpenSCManager(PChar(sMachine),Nil,SC_MANAGER_ALL_ACCESS) always return 0 under Win7, causing the problem. Any ideas and if possible, any workaround apart from "run as administrator". Regards Ronaldo

    Read the article

  • number of days in a period that fall within another period

    - by thomas
    I have 2 independent but contiguous date ranges. The first range is the start and end date for a project. Lets say start = 3/21/10 and end = 5/16/10. The second range is a month boundary (say 3/1/10 to 3/31/10, 4/1/10 to 4/30/10, etc.) I need to figure out how many days in each month fall into the first range. The answer to my example above is March = 10, April = 30, May = 16. I am trying to figure out an excel formula or VBA function that will give me this value. Any thoughts on an algorithm for this? I feel it should be rather easy but I can't seem to figure it out. I have a formula which will return TRUE/FALSE if ANY part of the month range is within the project start/end but not the number of days. That function is below. return month_start <= project_end And month_end >= project_start

    Read the article

  • Problem measuring N times the execution time of a code block

    - by Nazgulled
    EDIT: I just found my problem after writing this long post explaining every little detail... If someone can give me a good answer on what I'm doing wrong and how can I get the execution time in seconds (using a float with 5 decimal places or so), I'll mark that as accepted. Hint: The problem was on how I interpreted the clock_getttime() man page. Hi, Let's say I have a function named myOperation that I need to measure the execution time of. To measure it, I'm using clock_gettime() as it was recommend here in one of the comments. My teacher recommends us to measure it N times so we can get an average, standard deviation and median for the final report. He also recommends us to execute myOperation M times instead of just one. If myOperation is a very fast operation, measuring it M times allow us to get a sense of the "real time" it takes; cause the clock being used might not have the required precision to measure such operation. So, execution myOperation only one time or M times really depends if the operation itself takes long enough for the clock precision we are using. I'm having trouble dealing with that M times execution. Increasing M decreases (a lot) the final average value. Which doesn't make sense to me. It's like this, on average you take 3 to 5 seconds to travel from point A to B. But then you go from A to B and back to A 5 times (which makes it 10 times, cause A to B is the same as B to A) and you measure that. Than you divide by 10, the average you get is supposed to be the same average you take traveling from point A to B, which is 3 to 5 seconds. This is what I want my code to do, but it's not working. If I keep increasing the number of times I go from A to B and back A, the average will be lower and lower each time, it makes no sense to me. Enough theory, here's my code: #include <stdio.h> #include <time.h> #define MEASUREMENTS 1 #define OPERATIONS 1 typedef struct timespec TimeClock; TimeClock diffTimeClock(TimeClock start, TimeClock end) { TimeClock aux; if((end.tv_nsec - start.tv_nsec) < 0) { aux.tv_sec = end.tv_sec - start.tv_sec - 1; aux.tv_nsec = 1E9 + end.tv_nsec - start.tv_nsec; } else { aux.tv_sec = end.tv_sec - start.tv_sec; aux.tv_nsec = end.tv_nsec - start.tv_nsec; } return aux; } int main(void) { TimeClock sTime, eTime, dTime; int i, j; for(i = 0; i < MEASUREMENTS; i++) { printf(" » MEASURE %02d\n", i+1); clock_gettime(CLOCK_REALTIME, &sTime); for(j = 0; j < OPERATIONS; j++) { myOperation(); } clock_gettime(CLOCK_REALTIME, &eTime); dTime = diffTimeClock(sTime, eTime); printf(" - NSEC (TOTAL): %ld\n", dTime.tv_nsec); printf(" - NSEC (OP): %ld\n\n", dTime.tv_nsec / OPERATIONS); } return 0; } Notes: The above diffTimeClock function is from this blog post. I replaced my real operation with myOperation() because it doesn't make any sense to post my real functions as I would have to post long blocks of code, you can easily code a myOperation() with whatever you like to compile the code if you wish. As you can see, OPERATIONS = 1 and the results are: » MEASURE 01 - NSEC (TOTAL): 27456580 - NSEC (OP): 27456580 For OPERATIONS = 100 the results are: » MEASURE 01 - NSEC (TOTAL): 218929736 - NSEC (OP): 2189297 For OPERATIONS = 1000 the results are: » MEASURE 01 - NSEC (TOTAL): 862834890 - NSEC (OP): 862834 For OPERATIONS = 10000 the results are: » MEASURE 01 - NSEC (TOTAL): 574133641 - NSEC (OP): 57413 Now, I'm not a math wiz, far from it actually, but this doesn't make any sense to me whatsoever. I've already talked about this with a friend that's on this project with me and he also can't understand the differences. I don't understand why the value is getting lower and lower when I increase OPERATIONS. The operation itself should take the same time (on average of course, not the exact same time), no matter how many times I execute it. You could tell me that that actually depends on the operation itself, the data being read and that some data could already be in the cache and bla bla, but I don't think that's the problem. In my case, myOperation is reading 5000 lines of text from an CSV file, separating the values by ; and inserting those values into a data structure. For each iteration, I'm destroying the data structure and initializing it again. Now that I think of it, I also that think that there's a problem measuring time with clock_gettime(), maybe I'm not using it right. I mean, look at the last example, where OPERATIONS = 10000. The total time it took was 574133641ns, which would be roughly 0,5s; that's impossible, it took a couple of minutes as I couldn't stand looking at the screen waiting and went to eat something.

    Read the article

  • am i returning the correct values?

    - by phill
    I wrote the following code: import java.lang.*; import DB.*; private Boolean validateInvoice(String i) { int count = 0; try { //check how many rowsets ResultSet c = connection.DBquery("select count(*) from Invce i,cust c where tranid like '"+i+"' and i.key = c.key "); while (c.next()) { System.out.println("rowcount : " + c.getInt(1)); count = c.getInt(1); } if (count > 0 ) { return TRUE; } else { return FALSE; } //end if } catch(Exception e){e.printStackTrace();return FALSE;} } The errors I'm getting are: i.java:195: cannot find symbol symbol : variable TRUE location: class changei.iTable return TRUE; i.java:197: cannot find symbol symbol : variable TRUE location: class changei.iTable return FALSE; i.java:201:: cannot find symbol symbol : variable FALSE location: class changei.iTable catch(Exception e){e.printStackTrace();return FALSE;} The Connection class comes from the DB package i created. Is the return TRUE/FALSE correct since the function is a Boolean return type?

    Read the article

  • BSOD when using Visual Studio 2008

    - by I'm raaaaageeed
    Man, I am so fucking mad right now that my hand is broken from punching my piece of shit laptop. Fucking I'm in Visual Studio trying to get work done, and the piece of shit keeps telling me "LOL VSHost.exe crashed!" So I'm like fuck you you little piece of shit and keep ignoring it Then now everytime I start VS2008 and start working on a project I get the following blue screen: STOP: 0x0000007E (0xC000001D, 0x80573002*, 0xF78E6840, 0xF78E653C) = *can barely read my own handwriting on that one sorry lool Btw VSHost.exe was crashing in the mscorwks.dll FUCKING HELP ME I HAVE SO MUCH WORK TO DO

    Read the article

  • help with linq query

    - by Luis
    Hi, i am trying to get some data, but i dont know how can i do a if in linq, this is how i am trying to do from so in db.Operations where ((opType!= "0" ? so.Operation == int.Parse(opType) : false) && (idState!=0 ? so.State == idState : false) && (start != null ? so.StartDate == start : false) && (end !=null ? so.EndDate == end : false)) select so the optype is a Int, the idState is a Int, end is a datetime, start is a datime what i am trying to do is, if those aren't null they add to the query function, so i can get all data together

    Read the article

  • Ubuntu 12.04 crash analysis - strange binary data on all open files at the moment of crash

    - by lanbo
    A couple of hours ago we got a system crash on Ubuntu 12.04. We checked all the log files and there is nothing suspicious to blame to. Last stuff that was logged was some dovecot activity. There are no kernel panic messages. Nothing. It is a new server (new hardware) we are testing before production. And because it is new hard, I'm suspicious the problem may be due to some faulty hardware. We already run memtester with no problem detected. I'll be happy to hear from other hardware testing tools (the machine has SSD). Anyway, the thing I wanted to ask you is a different one. The strange thing is on every open file at the moment of the crash we found the next sequence of symbols was written into them: "@^@^@^@^@^@^@...". For example, on the syslog log file we got: Apr 16 15:53:56 odyssey dovecot: pop3-login: Aborted login (auth failed, 1 attempts): user=<info>, method=PLAIN, rip=46.29.255.73, lip=5.9.58.177 ^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^@^ [these continues for about 1000 chars...] ^@^@^@^@Apr 16 15:55:12 odyssey kernel: imklog 5.8.6, log source = /proc/kmsg started. We got all these symbols in all open files. These include: syslog, mail.log, kern.log, ... But also on some logs that are output by php scripts run in CRONs from user accounts (not root). So, any idea why all open files got these characters written during the crash? This is pretty bad since the crash corrupted many files (we don't even know which other ones may be affected). We are suspicious that all open files (in write mode maybe) at the moment of the crash got all these symbols inserted. Why is that? BTW [in case it helps], the system automatically rebooted after the crash but Apache did not start. There were not traces in /var/apache2/*log why apache did not start. After running a "service apache2 start" it started with no problems. Also, we rebooted the machine manually and Apache also started on reboot. But it did not start after the crash and no errors were reported. Thanks guys!

    Read the article

  • Access denied on virtual machine

    - by newbie
    I have a friend on the same network as me hosting a virtual machine using vmware server.The guest OS is Windows 7 and Windows Server 2003.He granted me administrative priveleges for the machine but when i try to add a user to that VM it says access denied. Moreover when i try to start the VM remotely using the command vmrun -T server -h https://computer-name.domain.com:8333/sdk -u domain/user -p passwd start "[standard] Win2k3Client1/Win2k3Client1.vmx" This shows unsufficient priveleges on host operating system but i am able to login with same username password on VMWare Web Access

    Read the article

  • "Error 1067: The process terminated unexpectedly" when trying to install MySQL on Win7 x64.

    - by Gravitas
    Hi, I've run into a brick wall trying to install MySQL v5.5 on my machine. My PC is Windows 7 x64, Enterprise edition. MySQL installs fine, but when I run the "MySQL Instance Configuration Wizard", it pauses forever on the step "Start Service" (I can let it run for 30 minutes with no response). If I go into services, I see that the "MySQL" service hasn't started, and if I try to start it, it says "Windows could not start MySQL Service on Local Computer. Error 1067: The process terminated unexpectedly." I've tried the following: Turning off firewall. Uninstalling all antivirus software. Installing / reinstalling 32-bit version of MySQL. Installing / reinstalling 64-bit version of MySQL. Uninstalling, deleting the contents of "C:\program files\MySQL" and "C:\program files (x86)\MySQL", reinstalling. Checking to see that there is no rogue services named MySQL???? (from a previous install). Checking that port 3306 is not used by an alternate program. Changing the default port that MySQL uses. Checking for "my.ini" and "my.ini.cnf" in "C:\windows" (nothing there but that can cause a problem). Running both MySQL installer, and configuration wizard, in "Adminstrator mode". Turning off UAC. Installing with defaults, not changing anything. Rebooting my machine (about 6 reboots so far). Opening up port 3306 in the firewall (both TCP and UDP, inbound and outbound). Swearing at the klutz of a programmer who designed MySQL so you can't even install it (as if that would help!) My machine is working 100% in every other way. InfiniDB (a MySQL compatible database) installs 100%, as does Visual Studio 2010, Microsoft SQL Server, etc, etc. Your advice on how to work around this? p.s. Here is the screen it got stuck on for 15 minutes until I killed the process: Update 2010-12-20 Tried MySQL v5.1, it didn't work either. Its amazing - if you type "mysqld /?", or "mysqld -help", it doesn't give you any help. And, if you try to restart the service manually, it doesn't display any error messages. Could it be any more unhelpful? Update 2010-12-21 Installed MySQL 6.0 alpha, and it worked. However, I'd rather not use an alpha release, given that the "stable" release is anything but :( Update 2010-12-21 Found http://dev.mysql.com/doc/refman/5.1/en/windows-troubleshooting.html, dealing with troubleshooting under Windows. Discovered that you can generate an error log if the service doesn't start - see here: http://dev.mysql.com/doc/refman/5.1/en/error-log.html

    Read the article

  • maven: Including module assembly into assembly of parent project

    - by Ilya Izhovkin
    I have a set of projects, each has been configured to build with maven, and each has assembly plugin enabled. So, I have something like that: project1/ target/ lib/ ... project1-1.0.jar start.sh ... project2/ target/ lib/ ... project2-1.0.jar start.sh ... I need to create parent project, and configure assembly for it, which must include all subproject's assemblies. parent_project/ target/ project1/ lib/ ... project1-1.0.jar project2/ lib/ ... project2-1.0.jar start.sh ... How can I achieve this?

    Read the article

  • Full Text Search in MSSQL2008 shows wrong display_item for Thai language

    - by ensecoz
    I am working with MSSQL2008. My task is to investigate the issue where FTS cannot find the right result for Thai. First, I have the table which enables the FTS on the column 'ItemName' which is nvarchar. The Catalog is created with the Thai Language. Note that the Thai language is one of the languages that doesn't separate the word by spaces, so '????' '???' '????' are written like this in a sentence: '???????????' In the table, there are many rows that include the word (????); for example row#1 (ItemName: '???????????') On the webpage, I try to search for '????' but SQLServer cannot find it. So I try to investigate it by trying the following query in SQLServer: select * from sys.dm_fts_parser(N'"???????????"', 1054, 0, 0) ...to see how the words are broken. The first one is the text to be broken. The second parameter is to specify that we're using Thai (WorkBreaker, so on). Here is the result: row#1 (display_item: '????', source_item: '???????????') row#2 (display_item: '????', source_item: '???????????') row#3 (display_item: '??', source_item: '???????????') Notice that the first and second row display the wrong display_item '?' in the '????' isn't even Thai characters. '?' in '????' is not a Thai character either. So the question is where did those alien characters come from? I guess this why I cannot search for '????' because the word breaker is broken and keeping the wrong character in the indexes. Please help!

    Read the article

  • Script execution flow stopped?

    - by vijay.shad
    Hi all, Now my script is able to start server, But I am still have some problem with my script. When the start server command is executed, the control does not pass the line and does not execute further of that line. Please tell me what is the problem and how can I get smooth execution of the my script.

    Read the article

  • how do i claim a low-numbered port as non-root the "right way"

    - by qbxk
    I have a script that I want to run as a daemon listening on a low-numbered port (< 1024) Script is in python, though answers in perl are also acceptable. The script is being daemonized using start-stop-daemon in a startup script, which may complicate the answer What I really (think) don't want is to type ps -few and see this process running with a "root" on it's line. How do I do it? ( from my less-than-fully-educated-about-system-calls perspective, I can see 3 avenues, Run the script as root (no --user/--group/--chuid to start-stop-daemon), and have it de-escalate it's user after it claims the port Setuid root on the script (chmod u+s), and run the script as the running user, (via --user/--group/--chuid to start-stop-daemon, the startup script still has to be called as root), in the script, acquire root privileges, claim the port, and then revert back to normal user something else i'm unaware of )

    Read the article

  • stylesheet_link_tag producing absolute links instead of relative

    - by mathee
    I set up facebooker to tunnel my Ruby on Rails application. The issue is that I would like to test locally. That is, I don't want to have to start a tunnel every time I want to see my changes. Right now, when I start the application using ruby script/server (not calling rake facebooker:tunnel:background_start beforehand), links created by helpers (e.g., stylesheet_link_tag, javascript_include_tag, image_tag) are prepended with my tunnlr address: http://web1.tunnlr.com:myPort/. (For example, a CSS link looks like this in the page source: http://web1.tunnlr.com:myPort//stylesheets/appName.css?1234567890.) I don't want that functionality; I can't see my CSS or JavaScript changes without having to start the tunnel first. I want the links to be relative, not absolute. So, stylesheet_link_tag should produce /stylesheets/appName.css?1234567890. Does anyone know why it's doing that in the first place and how to fix it? Thanks in advance.

    Read the article

  • SQL to return dates that fall in period and range

    - by Nate
    Hey stackers, I’ve been grinding my head on this for a while… My goal is to return all dates that fall between a start and end date and have a certain period as a factor, from the start date. (hard to explain) For example… Start Date: Nov 20, 1987; End Date: Jan 01, 1988; Period: 10 days; I want these dates: Nov 20, 1987; Nov 30, 1987; Dec 10, 1987; Dec 20, 1987; Dec 30, 1987; I already have a date table with all dates from 1900 to 2099. The period could be by days, months or years. Any ideas? Let me know if you need more info.

    Read the article

  • Monit network availability checking

    - by viraptor
    Hi, I'd like to start a service with monit but only when I have the correct ip bound to the host. Can this be done somehow with the normal config? For example I want to start a process xxx with pidfile xxx.pid, but only if host currently has 10.0.0.1 bound to some interface.

    Read the article

  • Linux issues on setting a timer function

    - by laura
    I am creating a process with 2 children, 1 of the children is responsible to read questions (line by line from a file), output every question and reading the answer, and the other one is responsable to measure the time elapsed and notify the user at each past 1 minute about the remaining time. My problem is that i couldn't find any useful example of how i can make this set time function to work. Here is what i have tried so far. The problem is that it outputs the same elapsed time every time and never gets out from the loop. #include<time.h> #define T 600000 int main(){ clock_t start, end; double elapsed; start = clock(); end = start + T; while(clock() < end){ elapsed = (double) (end - clock()) / CLOCKS_PER_SEC; printf("you have %f seconds left\n", elapsed); sleep(60); } return 0; }

    Read the article

  • lexical analysis gives only one output?

    - by Caffè
    I tested this example(lexe.java), but it gave me only one output. I gave this text as a reader: public class LexeTest{ private int a = 14; } And the nextToken() function is : public Category nextToken () { if (inp.findWithinHorizon (tokenPat, 0) == null) return Category.EOF; else { lastLexeme = inp.match ().group (0); if (inp.match ().start (1) != -1) return nextToken (); else if (inp.match ().start (2) != -1) return Category.IDENT; else if (inp.match ().start (3) != -1) return Category.NUMERAL; Category result = tokenMap.get (lastLexeme); if (result == null) return Category.ERROR; else return result; } } Isdie the main method: System.out.println(lexeObject.nextToken()); output is : IDENT Why? but the textfile contains multiple keywords? Anyone know what's the problem?

    Read the article

  • How to completely wipe rubygems along with rails etc

    - by Earlz
    Ok, so I decided I'd be cool and try to use Rails3 that's in beta. Then, things were getting hard to manage so I got rvm. I installed ruby 1.9.2-head in rvm and things were working, and then a computer restart later rails wouldn't start up. So I figured I'd just try running the system ruby and start rails in it. same error. Then, I uninstalled rails3 and got rails: no such file or directory type errors.. So now I'm royally screwed because rails2 is still installed but will not uninstall because of invisible dependencies, along with a lot of other random gems. How do I completely clear out all ruby gems and such so I can start anew?

    Read the article

  • What is the best place to setup system wide environment variables on Linux?

    - by Sorin Sbarnea
    I just want to setup a system wide environment variable, JAVA_HOME for all users, including root user. Requirements: accessible to normal users accessible to root always loaded, not only for bash (gnome-terminal does not start a bash by default) to work on Ubuntu, Debian and optionally Red Hat great if addition could be easily scripted So far here is the no-list: /etc/profile.d/java.sh - not executed if you start a new console from gnome-terminal /etc/profile - same as above ~/.profile - current user only, also any solution assuming ~ would not be acceptable because home directory could be on NIS, and JAVA_HOME could be different.

    Read the article

  • Windows 7 boot problem

    - by nijikunai
    My system doesn't boot at all, upon starting it takes me to the Windows Error Recovery screen saying "Windows failed to start, a recent software or hardware change might be the cause" and gives two options Launch System Repair (Recommended) Start Windows normally But neither options work, upon clicking either of them, some progress bars get displayed and the screen just freezes on "Starting Windows". I tried booting from the Windows 7 disk but it too freezes on the "Starting Windows" screen. I even tried booting from ubuntu, slax linux, but they don't work too.

    Read the article

  • How do I extend the virsh/qemu/libvirt Timeout?

    - by Nick
    There's a known issue with starting virtual machines with large hard drive images. Apparently, the time-out is 3 seconds, but in reality, it can take up to 15 seconds for a machine to start. I've read several bug reports, and people confirming it's a time-out problem, but I have yet to see a solution. Is there an option I can pass, like: virsh start MyMachine --ignore-timeout Or a config file that needs changed? Thanks!

    Read the article