Search Results

Search found 27229 results on 1090 pages for 'default aspx'.

Page 328/1090 | < Previous Page | 324 325 326 327 328 329 330 331 332 333 334 335  | Next Page >

  • Do Hyper-V guests see multiple CPUs (sockets) or multiple CPU cores when assigned more than 1 vCPU?

    - by Filip Kierzek
    I have SQL Server 2008 Express running on Hyper-V based virtual machine with two vCPU-s. I've just been reading up on SQL Server 2012 Express and noticed that it's CPU is "Limited to lesser of 1 Socket or 4 cores" (http://msdn.microsoft.com/en-us/library/cc645993(v=SQL.110).aspx) My question is how do the SQL Server 2012 limits on CPUs/Cores translate into vCPU-s? Are they "processors" or are they "cores"?

    Read the article

  • How to sync two computers using new MobileMe calendar

    - by CesarGon
    I have been using MobileMe for over a year with success. I use it to sync my Outlook calendars in my work and home computers, using Windows 7 and Outlook 2007. The main Outlook calendar folder in my work computer is replicated to MobileMe as "Work", and synced to my home computer, and the main calendar folder in my home computer is replicated to MobileMe as "Home", and synced to my work computer. This means that I can see both "Work" and "Home" calendars from both computers (as well as from the web interface through me.com), which is very convenient. Yesterday I migrated to the new MobileMe calendar, accepting the suggestion that popped up on the me.com website. After the migration, the MobileMe control panel on each of Windows computers asked me to re-configure my calendar setup, and everything fell apart. The "Home" and "Work" calendar folders in Outlook are now ignored by MobileMe, and new ones named "Home in MobileMe" and "Work in MobileMe" have been created, and placed in a separate Outlook data file rather than the default. This means that now: I now have four folders, two of which are not replicated to MobileMe The two folders that are not replicated reside on a separate data file, so alarms and reminders don't work; they're basically useless to me as calendar folders In addition, the button in the MobileMe Control Panel that used to let me specify what MobileMe folder should be synced against the default Outlook folder has gone. MobileMe is now too smart. Do you have any idea how to undo this mess and go back to a situation where I have two folders, as described in the top paragraph, which keep synced? I don't want an extra data file. Thanks.

    Read the article

  • MySQL encoding problem after site move

    - by Quan Zhou
    Guys, I need your help. Since last month my friend has lost his database on Dreamhost, he decided to move his wordpress based blog site (written in Chinese) to my server. He's using a wp-plugin called wp-db-backup to perform regular db backups. And the servers backgrounds are: Dreamhost: Linux 2.6.31.5-modsign-aufs2-grsec-2-opt mysql Ver 14.12 Distrib 5.0.16, for pc-linux-gnu (i386) using readline 5.0 apache2 unknown version My Server: Linux li159-46 2.6.32.12-x86_64-linode12 mysql Ver 14.14 Distrib 5.1.45, for debian-linux-gnu (x86_64) using readline 6.1 nginx 0.8.36 His site's encoding was UTF-8 in both wp-config and db. I imported his db backup file in UTF-8 by default, then I sync'd files using rsync from dreamhost, then I just changed the db address and nothing more. But when I take first look at the "new" site, it was full of unreadable characters, I met this problem before, I changed charset options in browser but none of them can make it displayed properly. Then I converted his db to GB18030, it works with only if browser set charset to GB18030 either GBK, but by default they recognize the charset as UTF-8. I tried to edit the headers but it doesn't work. What could I do now? Thx~~

    Read the article

  • nginx: SSI working on Apache backend, but not on gunicorn backend

    - by j0nes
    I have nginx in front of an Apache server and a gunicorn server for different parts of my website. I am using the SSI module in nginx to display a snippet in every page. The websites include a snippet in this form: For static pages served by nginx everything is working fine, the same goes for the Apache-generated pages - the SSI include is evaluated and the snippet is filled. However for requests to my gunicorn backend running a Python app in Django, the SSI include does not get evaluated. Here is the relevant part of the nginx config: location /cgi-bin/script.pl { ssi on; proxy_pass http://default_backend/cgi-bin/script.pl; include sites-available/aspects/proxy-default.conf; } location /directory/ { ssi on; limit_req zone=directory nodelay burst=3; proxy_pass http://django_backend/directory/; include sites-available/aspects/proxy-default.conf; } Backends: upstream django_backend { server dynamic.mydomain.com:8000 max_fails=5 fail_timeout=10s; } upstream default_backend { server dynamic.mydomain.com:80; server dynamic2.mydomain.com:80; } proxy_default.conf: proxy_redirect off; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; What is the cause for this behaviour? How can I get SSI includes working for my pages generated on gunicorn? How can I debug this further?

    Read the article

  • really weird DNS problem in Ubuntu {after one month, seems like ISP problem}

    - by OmniWired
    Hello everyone. I been having this random dns problem, in Ubuntu 10.04 and in 10.10 it started about 2 weeks ago after (I believe) an update. Basically when I go to a website randomly I get that the website I'm visiting is not available ("Oops! Google Chrome could not connect to ..." & "This webpage is not available."). I tested with Chromium "7.0.515.0 (58587)" and Firefox minefield (4.0ish) and 3.6.9. I did these 4 things already: /etc/default/grub GRUB_CMDLINE_LINUX="ipv6.disable=1" and this: /etc/sysctl.conf net.ipv6.conf.all.disable_ipv6 = 1 net.ipv6.conf.default.disable_ipv6 = 1 net.ipv6.conf.lo.disable_ipv6 = 1 *disabling Chromium DNS pre-fetching *using Google and OpenDNS servers as well as ISP DNS servers. But didn't improve, also no other computers in my network have the same problem. All computer wired to the same router. I'm a software engineer that run out of ideas, please help me. Thanks in advance. UPDATE: some programs (synaptic / firefox update/ vuze(azureus)) say connection refused for the error. Most of the time a second try will fix the "refusal". UPDATE2: I found out with Wireshark, that everytime I have this problem i've got this 192.168.0.10 8.8.8.8 ICMP Destination unreachable (Port unreachable) Confirmed an ISP error. ISP;Speedy Location: Argentina, Buenos Aires (capital Federal) Area.

    Read the article

  • Windows 7 x64 wired connection problem. IP, gateway, dns assigned, can't ping. Network detected as "Network"

    - by Emil Lerch
    I am having a problem connecting to a specific wired network with my Latitude E6410 laptop. Other wired networks seem to work fine, but this one does not. I have a coworker with me with the same Intel 82577LM Gigabit Network card, and he can connect just fine. I've updated to the latest Intel drivers (11.8.75.0) and am not using Pro Set. I obtain all DHCP information just fine (IP, netmask, DNS server, default gateway). I cannot ping anything (internal or on the Internet - I tried pinging Google's public DNS servers by IP 8.8.8.8), nor can I get answers to any DNS queries through NS Lookup. Windows troubleshooting says everything is fine, but I can't get DNS responses. I've seen issues like this in the past that were related to link speed/duplex autonegotiaion failures, so I've tried manually setting link speed/duplex to all values one by one with no success. My coworker is using all default settings, so he is just using autonegotiate. Any ideas of other things to try?

    Read the article

  • How can i use the `eject` command on a computer i have SSH'd into?

    - by will
    So if i do eject on my machine, it works exactly as expected, however, if i ssh into the machine next to me, and do the same thing, it does not work... my computer: eject: using default device `cdrom' eject: device name is `cdrom' eject: expanded name is `/dev/cdrom' eject: `/dev/cdrom' is a link to `/dev/sr0' eject: `/dev/sr0' is not mounted eject: `/dev/sr0' is not a mount point eject: checking if device "/dev/sr0" has a removable or hotpluggable flag eject: `/dev/sr0' is not a multipartition device eject: trying to eject `/dev/sr0' using CD-ROM eject command eject: CD-ROM eject command succeeded other computer: eject: using default device `cdrom' eject: device name is `cdrom' eject: expanded name is `/dev/cdrom' eject: `/dev/cdrom' is a link to `/dev/sr0' eject: `/dev/sr0' is not mounted eject: `/dev/sr0' is not a mount point eject: checking if device "/dev/sr0" has a removable or hotpluggable flag eject: `/dev/sr0' is not a multipartition device eject: unable to open `/dev/sr0' if i look in the /dev/ dir, then i find cdrom which is a symlink to sr0 - as mentioned by the verbose outputs of eject -v. On my machine, if i try and look at it, if the drive is open, it will close it, and then give this: $ less sr0 sr0 is not a regular file (use -f to see it) so $ less -f sr0 sr0: No medium found but if i do it on the other computer, $ less -f sr0 sr0: Permission denied so i look at the files more, and get this on both machines: $ ls -la sr0 brw-rw----+ 1 root cdrom 11, 0 Nov 12 10:13 sr0 Does anyone know a way around this? I do not have root access.

    Read the article

  • Migrating SBS 2003 to 2011, and hangs when migrating Public Folders

    - by Daniel P
    I've been following the migration guide at http://www.it-book.co.uk/1651/migration-from-sbs-2003-to-sbs-2011-3. The option "Migrate Exchange mailbox and settings" links me to http://technet.microsoft.com/en-us/library/gg563803.aspx When I get to the stage of right-clicking "Move All Replicas", it instantly hangs. I can't see anything specifically in the event viewer at the time this happens. Is this a case of waiting, or is there something more going on here?

    Read the article

  • Abysmal transfer speeds on gigabit network

    - by Vegard Larsen
    I am having trouble getting my Gigabit network to work properly between my desktop computer and my Windows Home Server. When copying files to my server (connected through my switch), I am seeing file transfer speeds of below 10MB/s, sometimes even below 1MB/s. The machine configurations are: Desktop Intel Core 2 Quad Q6600 Windows 7 Ultimate x64 2x WD Green 1TB drives in striped RAID 4GB RAM AB9 QuadGT motherboard Realtek RTL8810SC network adapter Windows Home Server AMD Athlon 64 X2 4GB RAM 6x WD Green 1,5TB drives in storage pool Gigabyte GA-MA78GM-S2H motherboard Realtek 8111C network adapter Switch dLink Green DGS-1008D 8-port Both machines report being connected at 1Gbps. The switch lights up with green lights for those two ports, indicating 1Gbps. When connecting the machines through the switch, I am seeing insanely low speeds from WHS to the desktop measured with iperf: 10Kbits/sec (WHS is running iperf -c, desktop is iperf -s). Using iperf the other way (WHS is iperf -s, desktop iperf -c) speeds are also bad (~20Mbits/sec). Connecting the machines directly with a patch cable, I see much higher speeds when connecting from desktop to WHS (~300 Mbits/sec), but still around 10Kbits/sec when connecting from WHS to the desktop. File transfer speeds are also much quicker (both directions). Log from desktop for iperf connection from WHS (through switch): C:\temp>iperf -s ------------------------------------------------------------ Server listening on TCP port 5001 TCP window size: 8.00 KByte (default) ------------------------------------------------------------ [248] local 192.168.1.32 port 5001 connected with 192.168.1.20 port 3227 [ ID] Interval Transfer Bandwidth [248] 0.0-18.5 sec 24.0 KBytes 10.6 Kbits/sec Log from desktop for iperf connection to WHS (through switch): C:\temp>iperf -c 192.168.1.20 ------------------------------------------------------------ Client connecting to 192.168.1.20, TCP port 5001 TCP window size: 8.00 KByte (default) ------------------------------------------------------------ [148] local 192.168.1.32 port 57012 connected with 192.168.1.20 port 5001 [ ID] Interval Transfer Bandwidth [148] 0.0-10.3 sec 28.5 MBytes 23.3 Mbits/sec What is going on here? Unfortunately I don't have any other gigabit-capable devices to try with.

    Read the article

  • Using ddr2 and ddr3 together

    - by Noam
    I have a Gigabyte board called GA-EP45C-DS3. It has four DDR2 slots, and 2 DDR3 slots. I would like to use them in parallel, and achieve the result of 12gb RAM. Will it work? see: http://www.gigabyte.com.tw/Products/Motherboard/Products_Overview.aspx?ProductID=2870

    Read the article

  • Using ddr2 and ddr3 together

    - by Noam
    I have a Gigabyte board called GA-EP45C-DS3. It has four DDR2 slots, and 2 DDR3 slots. I would like to use them in parallel, and achieve the result of 12gb RAM. Will it work? see: http://www.gigabyte.com.tw/Products/Motherboard/Products_Overview.aspx?ProductID=2870

    Read the article

  • IIS 7 + Tomcat 7 - how to reach http://localhost:8080/my_app under e.g. http://my_app.local

    - by Sk8erPeter
    In brief: IIS 7 + Apache Tomcat 7 + isapi_redirect.dll: I have a deployed and working Tomcat-application available under http://localhost:8080/my_app. I would like to see the same content under http://my_app.local (and NOT the default Tomcat-site [which you can see below]). How can I do that? Longer explained: I have IIS 7 (7.5.7600.16385) and Apache Tomcat/7.0.22 installed. I deployed an application (let's call it "my_app") in Tomcat, which now can be reached at http://localhost:8080/my_app, works fine. I added a new web site in IIS panel with the path of the Tomcat deployed my_app, which looks like this: "c:\Program Files\Apache Software Foundation\Tomcat 7.0\webapps\my_app" I binded the host name my_app.local. After that, I configured isapi_redirect.dll like this (or that). Now, when I open http://my_app.local, I can see the default Tomcat site (see below). BUT under http://my_app.local I would like to see the same content as under http://localhost:8080/my_app. How can I do that? Thank you very much in advance!! my config files: isapi_redirect.properties (I made a dir junction to c:\tomcat, so this also works :) ) workers.properties uriworkermap.properties rewrites.properties (empty)

    Read the article

  • FTP Server on Centos 5.8 - Transfer fails randomly

    - by Diego
    Hi have ProFTPD runningon a brand new CentOS 5.8 server with Plesk, and its behaviour is inconsistent at best. I tried to transfer a directory from my PC, and every time I get a transfer failed on a random file. It's never the same one that fails, it just fails. Sometimes it's a .gif, sometimes it's a .css, sometimes it's a JPG. Of several hundred files, a dozen is always failing for no apparent reason. The error that I get is the following: COMMAND:> [27/11/2012 11:43:52] STOR main_border.gif [27/11/2012 11:43:53] 500 Invalid command: try being more creative ERROR:> [27/11/2012 11:43:53] Syntax error: command unrecognized. The above is just an example, the "command unrecognized" occurs with LIST and other commands as well. Here's the ProFTPD configuration, just in case: ServerName "ProFTPD" #ServerType standalone ServerType inetd DefaultServer on <Global> DefaultRoot ~ psacln AllowOverwrite on </Global> DefaultTransferMode binary UseFtpUsers on TimesGMT off SetEnv TZ :/etc/localtime Port 21 Umask 022 MaxInstances 30 ScoreboardFile /var/run/proftpd/scoreboard TransferLog /usr/local/psa/var/log/xferlog #Change default group for new files and directories in vhosts dir to psacln <Directory /var/www/vhosts> GroupOwner psacln </Directory> # Enable PAM authentication AuthPAM on AuthPAMConfig proftpd IdentLookups off UseReverseDNS off AuthGroupFile /etc/group Include /etc/proftpd.include Note: file /etc/proftpd.include is blank. The above is the default configuration set by Plesk 11. I don't know much of why is that way, my knowledge of Linux System Administration is very basic and the one of ProFTPD is a complete zero. Thanks in advance for the help. Update Issue experienced with CuteFTP and FileZilla. Update Replaced ProFTPd with PureFTPd, issue persists. Sometimes I get "command unrecognized", sometimes "failed to establish data connection". I'm starting to think that it could be a network issue, but I have completely zero knowledge of networking.

    Read the article

  • Internet doesn't work when enable local Lan

    - by rakesh yadav
    We have the following network setup: A) Router IP 192.168.51.49 B) Windows Server 2008 R2 with dual NIC: B1) WAN interface (192.168.0.2) ( Used for internet) B2) LAN interface (192.168.1.2) ( used for local connectivity) when i keep both LAN Enabled than my internet doesn't work, but if I disabled my local Lan than internet working fine. so please help me how can resolved this issue or should i need to do routing on my server Please find the below attached route print result C:\Users\Administrator>route print =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 192.168.51.49 192.168.51.50 276 0.0.0.0 0.0.0.0 192.168.30.227 192.168.30.228 266 192.168.30.224 255.255.255.240 On-link 192.168.30.228 266 192.168.30.228 255.255.255.255 On-link 192.168.30.228 266 192.168.30.239 255.255.255.255 On-link 192.168.30.228 266 192.168.51.48 255.255.255.240 On-link 192.168.51.50 276 192.168.51.50 255.255.255.255 On-link 192.168.51.50 276 192.168.51.63 255.255.255.255 On-link 192.168.51.50 276 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 202.56.230.5 255.255.255.255 192.168.51.49 192.168.51.50 21 202.56.230.6 255.255.255.255 192.168.51.49 192.168.51.50 21 192.168.26.124 255.255.255.255 192.168.51.49 192.168.51.50 21 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 192.168.51.50 276 224.0.0.0 240.0.0.0 On-link 192.168.30.228 266 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 192.168.51.50 276 255.255.255.255 255.255.255.255 On-link 192.168.30.228 266 =========================================================================== Persistent Routes: Network Address Netmask Gateway Address Metric 0.0.0.0 0.0.0.0 192.168.30.227 Default 0.0.0.0 0.0.0.0 192.168.51.49 Default ===========================================================================

    Read the article

  • IPv6 Routing / Subnetting

    - by nappo
    Recently I have installed Citrix Xen Server 6.2 on a machine. My Provider (Hetzner) gave me the IPv6 Subnet 2a01:4f8:200:xxxx::/64. Followed an article in the providers wiki (1) i got it working and can assign IPs to my guests (CentOS). However i can't assign a second IP to a single guest - it will result in a timeout. I'm not very familiar with IPv6 routing / subnetting - any help or tips for further troubleshooting is welcome! My Setup: XenServer 6.2 IPv6: 2a01:4f8:200:xxxx::2/112 ip -6 route: 2a01:4f8:200:xxxx::/112 dev xenbr0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 0 fe80::1 dev xenbr0 metric 1024 mtu 1500 advmss 1440 hoplimit 0 default via fe80::1 dev xenbr0 metric 1024 mtu 1500 advmss 1440 hoplimit 0 Guest 1 IPv6: 2a01:4f8:200:xxxx::3/64 IPv6: 2a01:4f8:200:xxxx::4/64 ip -6 route: 2a01:4f8:200:xxxx::/64 dev eth0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev eth0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 default via fe80::1 dev eth0 metric 1 mtu 1500 advmss 1440 hoplimit 4294967295 Guest 2 IPv6: 2a01:4f8:200:xxxx::5/64 Guest 1 IPv6 is working fine, Guest 2 too. As suggested by the wiki article (1) i split my /64 network into a /112. Is it right to set the host /112 and the guests /64? Why is that?

    Read the article

  • Windows Vista: Folder options not working

    - by Thomas Matthews
    I'm running Windows Vista Service Pack 2. I have the Folder Options set to "Open each folder in the same window." (Organize | Folder Options | General). Each time I open a folder, it opens in a new window. How do I get it to open each folder in the same window? I have tried the following techniques with no success: 1. Expand number of MBAG entries in Registry. (The number is 40,000 now.) 2. Delete Bags and MBAG entries in Registry. (Rebooted machine after, still no success). 3. Change to "Open each folder in its own window". Saved, then changed back. 4. Under View tab, changed "Remember each folder's view settings": unchecked, Apply to Folders, checked, Apply to folders. 5. Applied application from Annoyances.org. Still no success. 6. Clicked on Reset Default Options, then OK. (Opening in same fold is a default option!) Still unsucessful. I want the folders to open in the same window, just like the options say.

    Read the article

  • Xen PV packet loss

    - by Delphinator
    I'm having some serious issues with packetloss with one of my servers. This server is a somewhat old (P4-era) machine running Debian Squeeze and Xen 4.0. There are two domUs running on it (both also Debian Squeeze), one gateway and a fileserver. Unfortunatly the processor has no virtualization extensions, therefore only PV can be used. While investigating why our network seems to be slower than it should I found some pretty bad packet loss (~25%). After further investigation and several experiments I did a measurment between the dom0 and one of the domUs: Server listening on UDP port 5001 Receiving 1470 byte datagrams UDP buffer size: 110 KByte (default) ------------------------------------------------------------ ------------------------------------------------------------ Client connecting to dom0, UDP port 5001 Sending 1470 byte datagrams UDP buffer size: 110 KByte (default) ------------------------------------------------------------ [ 3] local 192.168.1.2(domU) port 33817 connected with 192.168.1.100(dom0) port 5001 [ 4] local 192.168.1.2(domU) port 5001 connected with 192.168.1.100(dom0) port 48606 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 46.3 MBytes 38.7 Mbits/sec [ 3] Sent 33020 datagrams [ 3] Server Report: [ 3] 0.0-10.0 sec 46.2 MBytes 38.6 Mbits/sec 0.030 ms 89/33019 (0.27%) [ 3] 0.0-10.0 sec 1 datagrams received out-of-order [ 4] 0.0-10.2 sec 43.0 MBytes 35.3 Mbits/sec 13.074 ms 11575/42256 (27%) tl;dr: 27% packet loss from dom0 to domU with 50Mbit UDP packets. Same thing happens from anywhere in the network. The problem gets better for smaller bandwidths (0.047% for 5Mbit) and worse for higher (59% for 200Mbit) ones. I did increase the CPU-weight of the dom0, there is no swapping going on, and actual networking-hardware is not involved. I never expected Xen (or anything related) to drop packets, and I'm completly clueless what to try next.

    Read the article

  • Multicast hostname lookups on OSX

    - by KARASZI István
    I have a problem with hostname lookups on my OSX computer. According to Apple's HK3473 document it says for v10.6: Host names that contain only one label in addition to local, for example "My-Computer.local", are resolved using Multicast DNS (Bonjour) by default. Host names that contain two or more labels in addition to local, for example "server.domain.local", are resolved using a DNS server by default. Which is not true as my testing. If I try to open a connection on my local computer to a remote port: telnet example.domain.local 22 then it will lookup the IP address with multicast DNS next to the A and AAAA lookups. This causes a two seconds lookup timeout on every lookup. Which is a lot! When I try with IPv4 only then it won't use the multicast queries to fetch the remote address just the simple A queries. telnet -4 example.domain.local 22 When I try with IPv6 only: telnet -6 example.domain.local 22 then it will lookup with multicast DNS and AAAA again, and the 2 seconds timeout delay occurs again. I've tried to create a resolver entry to my /etc/resolver/domain.local, and /etc/resolver/local.1, but none of them was working. Is there any way to disable this multicast lookups for the "two or more label addition to local" domains, or simply disable it for the selected subdomain (domain.local)? Thank you!

    Read the article

  • Using public interfaces on a server connected through a GRE tunnel

    - by Evan
    I'm pretty new to networking so please forgive any terminology mistakes. I have 2 servers connected with a GRE tunnel. Server1 (10.0.0.1) ---- Server2 (10.0.0.2) I want to be able to bind to the public IPs on Server2 using Server1. To do this, I setup virtual interfaces with Server2's public IPs on Server1 and then used routing rules on Server1 to route the packets through the GRE tunnel. On Server1: ip rule add from [Server2's first public IP] table gre ip rule add from [Server2's second public IP] table gre ip route add default via 10.0.0.2 dev gre1 table gre This works great and I can see the packets arriving via GRE on Server2. I can see the packet exiting the tunnel on Server2's gre1 device as shown: From Server1: ping -I [Server2's public ip] google.com tcpdump from Server2's GRE tunnel device: 12:07:17.029160 IP (tos 0x0, ttl 64, id 0, offset 0, flags [DF], proto ICMP (1), length 84) [Server2's public ip] > 74.125.225.38: ICMP echo request, id 6378, seq 50, length 64 This is exactly the packet I want. However, I'm not seeing it go out at all on eth0:0 (where Server2's public IP is bound to). I've tried to use routing rules to get packets coming from Server2's public IP (which would be coming out of dev gre1) to go through dev eth0 on the public default gateway and that doesn't work either. I'm at a loss, thank you to anyone who can help.

    Read the article

  • Desktop bigger than screen

    - by alex
    I am using MSI U115 11" netbook (OS: Windows XP Home, graphics card: Intel Graphics Media Accelerator 500) and today after I switched it on, desktop was bigger than screen. To be exact: screen resolution was set to the lowest possible and I could move mouse outside of screen (but only below - left, right and up worked normally, mouse could not exceed screen boundaries). I changed resolution back to normal, but the problem with desktop being bigger than screen remained (as before, only lower part - cannot see task bar, etc. When I hit windows button on keyboard, only upper part of menu start is visible). What I already tried was changing all kind of graphics and screen settings - none of them helped. I also tried to restore the system to few days before, but it didn't help neither. What can I do to make the desktop look "normally"? EDIT: Some additional info regarding screen: Sorry it's in polish - but let me explain. There are two screens I can choose (Monitor domyslny means default screen), but the second one (the default one) is not available. After I choose it and click apply number 1. is used (and as you can see it has only two resolutions available. There are more in the second one - but without 1024x600 though). The two ticked and grayed out options here are Use this screen as the main one and Enlarge Windows desktop to match this monitor's size. Too bad I cannot change them. When I choose the second screen, the first box is unchecked and grayed out. The second box is available to be changed but it doesn't matter anyway as after applying changes it reverts to the first screen anyway. EDIT: Intel Graphics Media Control Panel screenshot.

    Read the article

  • What's the best way to run Drupal and Django sites behind the same Varnish server?

    - by Alexis Bellido
    I have a high traffic website running with Drupal and Apache, five web servers behind a Varnish server load balancing. Let's say this site is example.com. I'm using five backends and a director like this in my default.vcl: director balancer round-robin { { .backend = web1; } { .backend = web2; } { .backend = web3; } { .backend = web4; } { .backend = web5; } } Now I'm working on a new Django project that will be a new section of this site running on example.com/new-section. After checking the documentation I found I can do something like this: sub vcl_recv { if (req.url ~ "^/new-section/") { set req.backend = newbackend; } else { set req.backend = default; } } That is, using a different backend for a subdirectory /new-section under the same domain. My question is, how do I make something like this work with my director and load balancing setup? I'm probably going to run two or more web servers (backends) with my new Django project, each one with a mix of Gunicorn, Nginx, and a few Python packages, and would like to put all of those in their own Varnish director to load balance. Is it possible to do use the above approach to decide which director to use?, like this: sub vcl_recv { if (req.url ~ "^/new-section/") { set req.director = newdirector; } else { set req.director = balancer; } } All suggestions welcome. Thanks!

    Read the article

  • Cisco ASA Site-to-Site VPN Dropping

    - by ScottAdair
    I have three sites, Toronto (1.1.1.1), Mississauga (2.2.2.2) and San Francisco (3.3.3.3). All three sites have ASA 5520. All the sites are connected together with two site-to-site VPN links between each other location. My issue is that the tunnel between Toronto and San Francisco is very unstable, dropping every 40 min to 60 mins. The tunnel between Toronto and Mississauga (which is configured in the same manner) is fine with no drops. I also noticed that my pings with drop but the ASA thinks that the tunnel is still up and running. Here is the configuration of the tunnel. Toronto (1.1.1.1) crypto map Outside_map 1 match address Outside_cryptomap crypto map Outside_map 1 set peer 3.3.3.3 crypto map Outside_map 1 set ikev1 transform-set ESP-AES-256-MD5 ESP-AES-256-SHA crypto map Outside_map 1 set ikev2 ipsec-proposal AES256 group-policy GroupPolicy_3.3.3.3 internal group-policy GroupPolicy_3.3.3.3 attributes vpn-idle-timeout none vpn-tunnel-protocol ikev1 ikev2 tunnel-group 3.3.3.3 type ipsec-l2l tunnel-group 3.3.3.3 general-attributes default-group-policy GroupPolicy_3.3.3.3 tunnel-group 3.3.3.3 ipsec-attributes ikev1 pre-shared-key ***** isakmp keepalive disable ikev2 remote-authentication pre-shared-key ***** ikev2 local-authentication pre-shared-key ***** San Francisco (3.3.3.3) crypto map Outside_map0 2 match address Outside_cryptomap_1 crypto map Outside_map0 2 set peer 1.1.1.1 crypto map Outside_map0 2 set ikev1 transform-set ESP-AES-256-MD5 ESP-AES-256-SHA crypto map Outside_map0 2 set ikev2 ipsec-proposal AES256 group-policy GroupPolicy_1.1.1.1 internal group-policy GroupPolicy_1.1.1.1 attributes vpn-idle-timeout none vpn-tunnel-protocol ikev1 ikev2 tunnel-group 1.1.1.1 type ipsec-l2l tunnel-group 1.1.1.1 general-attributes default-group-policy GroupPolicy_1.1.1.1 tunnel-group 1.1.1.1 ipsec-attributes ikev1 pre-shared-key ***** isakmp keepalive disable ikev2 remote-authentication pre-shared-key ***** ikev2 local-authentication pre-shared-key ***** I'm at a loss. Any ideas?

    Read the article

  • Linux support for TRIM on SSD drives

    - by DLux
    Does any know if there is a way to enable TRIM support on Linux for SSDs? This is included with Windows 7, and I was surprised that I couldn't find much information about it under Linux. Info on SSD and TRIM can be found here - http://www.anandtech.com/storage/showdoc.aspx?i=3531&p=10

    Read the article

  • Mounting a VirtualBox shared folder on boot with fstab in OpenSuse 11.3

    - by ccook
    I have followed the steps found here, however, the share is not mounted on boot. The share will mount if i run 'mount -a' after booting. Why would the share not mount on boot? 1 - Set up a Virtual Machine and install OpenSUSE 11.2 2 - Create a shared folder on host (HostFolder) 3 - Setup the shared folder in Virtualbox Via the Virtual Machine details or via Devices Shared Folders... 4 - Install dependencies for running the Virtualbox installer You need to install the right development kernelpackage for your machinetype (use 'zypper search -i kernel' to see what's installed) sudo zypper install make gcc kernel-source kernel-hosttype/default-devel 5 - Run the Virtual Machine and go to Devices Guest Additions This mounts an iso image in your OpenSUSE guest. 6 - Open a root terminal and run cd /usr/src/linux make oldconfig && make prepare && make scripts && make dep cp ../linux-obj/$HOSTTYPE/default/Module.symvers . make prepare A commenter on previously mentioned thread says this step is unnecessary but it doesn't work without on my system. I suggest trying step 7 first and returning to step 6 if that fails. * 7 - Run ./VirtualboxLinux yourhosttype .run from the mounted iso image. 8 - Create shared folder in OpenSUSE (GuestFolder) 9 - Test with sudo mount -t vboxsf HostFolder /home/user/GuestFolder It works? Great! Let's set up the system so it automounts for your regular useraccount instead of root-only access. 10 - Add this line to /etc/fstab HostFolder /home/user/GuestFolder vboxsf defaults,uid=1000,gid=1000 0 0 11 - It works for me but if it still doesn't automount after a reboot; sudo mount -a

    Read the article

  • ipmi - can't ping or remotely connect

    - by Fidel
    I've tried configuring the IPMI controller to accept remote connections, but I can't even ping it. Here is it status: #/usr/local/bin/ipmitool lan print 2 Set in Progress : Set Complete Auth Type Support : NONE PASSWORD Auth Type Enable : Callback : : User : NONE PASSWORD : Operator : PASSWORD : Admin : PASSWORD : OEM : IP Address Source : Static Address IP Address : 192.168.1.112 Subnet Mask : 255.255.255.0 MAC Address : 00:a0:a5:67:45:25 IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10 BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Enabled Gratituous ARP Intrvl : 8.0 seconds Default Gateway IP : 192.168.1.1 Default Gateway MAC : 00:00:00:00:00:00 802.1q VLAN ID : Disabled 802.1q VLAN Priority : 0 RMCP+ Cipher Suites : 0,1,2,3 Cipher Suite Priv Max : uaaaXXXXXXXXXXX : X=Cipher Suite Unused : c=CALLBACK : u=USER : o=OPERATOR : a=ADMIN : O=OEM # /usr/local/bin/ipmitool user list 2 ID Name Enabled Callin Link Auth IPMI Msg Channel Priv Limit 1 true false true true USER 2 admin true false true true ADMINISTRATOR # /usr/local/bin/ipmitool channel getaccess 2 2 Maximum User IDs : 5 Enabled User IDs : 2 User ID : 2 User Name : admin Fixed Name : No Access Available : callback Link Authentication : enabled IPMI Messaging : enabled Privilege Level : ADMINISTRATOR # /usr/local/bin/ipmitool channel info 2 Channel 0x2 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : multi-session Active Session Count : 0 Protocol Vendor ID : 7154 Volatile(active) Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available Non-Volatile Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available # /usr/local/bin/ipmitool chassis status System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : unknown Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false # arp Address HWtype HWaddress Flags Mask Iface 192.168.1.112 ether 00:A0:A5:67:45:25 C bond0 # /usr/local/bin/ipmitool -I lan -H 192.168.1.112 -U admin -P admin chassis power status Error: Unable to establish LAN session Unable to get Chassis Power Status In summary. It exists on the ARP list so arp's are being broadcast. I can't ping it and can't connect to it. Can anyone spot any glaring mistakes in the configuration? Many thanks, Fidel

    Read the article

< Previous Page | 324 325 326 327 328 329 330 331 332 333 334 335  | Next Page >