Search Results

Search found 11587 results on 464 pages for 'pseudo random numbers'.

Page 357/464 | < Previous Page | 353 354 355 356 357 358 359 360 361 362 363 364  | Next Page >

  • Hard Disk Not Counting Reallocated Sectors

    - by MetaNova
    I have a drive that is reporting that the current pending sectors is "45". I have used badblocks to identify the sectors and I have been trying to write zeros to them with dd. From what I understand, when I attempt writing data directly to the bad sectors, it should trigger a reallocation, reducing current pending sectors by one and increasing the reallocated sector count. However, on this disk both Reallocated_Sector_Ct and Reallocated_Event_Count raw values are 0, and dd fails with I/O errors when I attempt to write zeros to the bad sectors. dd works fine, however, when I write to a good sector. # dd if=/dev/zero of=/dev/sdb bs=512 count=1 seek=217152 dd: error writing ‘/dev/sdb’: Input/output error Does this mean that my drive, in some way, has no spare sectors to be used for reallocation? Is my drive just in general a terrible person? (The drive isn't actually mine, I'm helping a friend out. They might have just gotten a cheap drive or something.) In case it is relevant, here is the output of smartctl -i : Model Family: Western Digital Caviar Green (AF) Device Model: WDC WD15EARS-00Z5B1 Serial Number: WD-WMAVU3027748 LU WWN Device Id: 5 0014ee 25998d213 Firmware Version: 80.00A80 User Capacity: 1,500,301,910,016 bytes [1.50 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Fri Oct 18 17:47:29 2013 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled UPDATE: I have run shred on the disk, which has caused Current_Pending_Sector to go to zero. However, Reallocated_Sector_Ct and Reallocated_Event_Count are still zero, and dd is now able to write data to the sectors it was previously unable to. This leads me with several other questions: Why aren't the reallocations being recored by the disk? I'm assuming the reallocation took place as I can now write data directly to the sector and couldn't before. Why did shred cause reallocation and not dd? Does the fact that shred writes random data instead of just zeros make a difference?

    Read the article

  • Automated Linux VMs on Hyper-V 2012

    - by Mick
    I have a requirement to create a ton of linux VMs for our customers (we run managed infrastructure) on Hyper-V 2012 in the coming months and I have an issue with automating it. Here is how I need it to work: User accesses their web page and creates a VM. VM is created with a unique IP and name User logs in over SSH I know Hyper-V quite well and can work with powershell and am a C# programmer so the development side of things is taken care of. I also know enough about Linux to be at least competent: I have used it on and off for a number of years but not done anything Enterprise-level with it. All this can be done easily by manual processes but I need to be able to script or program this to automate it as there could be hundreds of them being created but I don't know how. My first thought is to have a database with random-generated names and IPs already created but I don't know how to get a Linux VM to boot up and grab one from the database... I suppose a Kickstart script would take care of it but I don't know what to do from there. Here is what is bouncing around in my head: Create a std linux build. - Easy to do Someone clicks "Create VM" and I pull a name and IP from the database and write it to a kickstart script. - Easy to do I could then open the template VHDX file and copy in the script and then save it. - Not sure if possible User boots up new VM and the kickstart script gives it the name and IP I assigned it. My problem is that I don't know how to open a VHDX file and insert a kickstart script into it... can't figure it out. I am reaching here and this solution may be miles off... I am more used to creating Windows VMs with scripts and so on which i am more familiar with... any help would be appreciated. Thanks Mick

    Read the article

  • Comparing 2 (or 3 Files If Possible) "Line By Line"

    - by PythEch
    I want to find out the differences of 2 (or 3 files if possible) line by line. Diff utils can do this, however it gives inaccurate results. Because, 2 files have exact number of lines which is "134". But diff gives me "Added Lines" and "Removed Lines". However this is wrong, they have exact the same number of lines, there is no added or removed lines. The text files which I want to find differences of them, have only numbers written, maybe that's why that algortihm fails. I couldn't find any option to prevent that, however I may be wrong, I mean there should be an option for that, but again, I couldn't find. This is what I get (5am.txt vs 6am.txt, there is a huge problem): This is what I want (6am.txt vs 7am.txt, still has problems): But, first the first image still has this problem, at the last lines. Edit: After I figured out that there is no utility to do this, I handled myself. I almost did the same thing as what RedGrittyBrick have done. This script imitates diff utility so I (or you) can use it with diff2html. To use it with diff2html, just change line diff_stdout = os.popen("diff %s" % string.join(argv[1:]), "r") to diff_stdout = os.popen("script.py %s" % string.join(argv[1:]), "r") and name this script whatever you want: import sys f1=open(sys.argv[1],"r") f1_read=f1.readlines() f1.close() f2=open(sys.argv[2],"r") f2_read=f2.readlines() f2.close() changed={} first_c = "" for n in range(len(f1_read)): if f1_read[n]!=f2_read[n]: if first_c == "": first_c=n+1 changed[first_c]=n+1 else: first_c="" #Let's imitate diff-utils... for (x, y) in changed.items(): print "%d,%dc%d,%d" % (x,y,x,y) for i in range(x,y+1): sys.stdout.write("< %s" % f1_read[i-1]) print "---" for i in range(x,y+1): sys.stdout.write("> %s" % f2_read[i-1]) Final results:

    Read the article

  • How browsers handle multiple IPs

    - by Sandman4
    Can someone direct me to information on exact browsers behavior when browser gets multiple A records for a given hostname (say ip1 and ip2), and one of them is not accessible. I interested in EXACT details, like (but not limited to): Will browser get 2 IPs from OS, or it will get only one ? Which ip will browser try first (random or always the first one) ? Now, let's say browser started with the failed ip1 For how long will browser try ip1 ? If user hits "stop" while it waits for ip1, and then clicks refresh which IP will browser try ? What will happen when it times-out - will it start trying ip2 or give error ? (And if error, which ip will browser try when user clicks refresh). When user clicks refresh, will any browser attempt new DNS lookup ? Now let's assume browser tried working ip2 first. For the next page request, will browser still use ip2, or it may randomly switch ips ? For how long browsers keep IPs in their cache ? When browsers sends a new DNS request, and get SAME ips, will it CONTINUE to use the same known-to-be-working IP, or the process starts from scratch and it may try any of the two ? Of course it all may be browser dependent, and may also vary between versions and platforms, I'd be happy to have maximum of details. The purpose of this - I'm trying to understand what exactly users will experience when round-robin DNS based used and one of the hosts fails. Please, I'm NOT asking about how bad DNS load balancing is, and please refrain from answering "don't do it", "it's a bad idea", "you need heartbeat/proxy/BGP/whatever" and so on.

    Read the article

  • Nginx proxy to IIS Connection Timeout

    - by MitMaro
    I am having an issue with random timeouts with a Nginx proxy connecting to an IIS machine. I have been watching a packet capture between the two servers and it seems that the IIS machine is receiving a SYN packet but is not responding with what I think should be an ACK response. Before the timeout occurs there seems to be a slower response from the IIS server. There is no unusual memory or processor usage on the IIS or Nginx machine. Some information on the servers and setup: Nginx Machine: Ubuntu 10.04 64bit Nginx 0.7.65 Amazon EC2 Windows Machine: Windows Server 2008 IIS 7 ASP.net Application in Integrated Mode Nginx Error: 2011/01/10 17:57:40 [error] 8297#0: *30 connect() failed (110: Connection timed out) while connecting to upstream, client: 209.***.***.***, server: secure.example.com, request: "GET /a/path/deliver.aspx HTTP/1.1", upstream: "http://***.***.***.****:****//another/path/deliver.aspx", host: "secure.example.com" WireShark Packets 6521.449528 10.***.***.*** -> 174.***.***.*** TCP 38695 > us-cli [SYN] Seq=0 Win=5840 Len=0 MSS=1460 TSV=477422103 TSER=0 WS=7 6524.443239 10.***.***.*** -> 174.***.***.*** TCP 38695 > us-cli [SYN] Seq=0 Win=5840 Len=0 MSS=1460 TSV=477422403 TSER=0 WS=7 6530.443241 10.***.***.*** -> 174.***.***.*** TCP 38695 > us-cli [SYN] Seq=0 Win=5840 Len=0 MSS=1460 TSV=477423003 TSER=0 WS=7

    Read the article

  • Why are certain folders in my XP network share really, really slow?

    - by bikefixxer
    I have a workgroup set up with Windows XP. My file "server" is running XP Pro and the clients are running XP home. I've turned simple file sharing off on the server because certain clients need access to certain folders and not to others, and I want to keep it that way. Therefore, I've used the granular sharing/security settings to enable certain clients access to certain folders. I'm using the net use command in a batch file on the clients to add the share when they logon so it's always available via a mapped drive or a shortcut. On some clients "My Documents" points to the mapped drive, but all of the local and application settings stay local. Everything works well except for accessing a certain folder on the network. It contains a lot of random batch files and self-executable programs I use for diagnostics and what not, and nearly every time I open the folder the computer hangs for 15-60 seconds. This happens on every machine, including the server (but not nearly as often as the clients). I've searched high and low and cannot figure it out and it's driving me crazy. Here are all the things I've tried to no avail: Disabled firewall (XP) and anti-virus (ESET NOD32) Deleted any desktop.ini file I can find in the share Disabled "automatically search for network folders and printers" Disabled "remember each folder's view settings" Set HKCU\Software\Microsoft\Windows\CurrentVersion\Policies\Explorer NoRecentDocsNetHood = 1 Tried with mapped drives and with UNC shortcuts Ran CHKDSK Removed Read-Only attribute from all folders (well, tried to remove, it always came back on with a half check) Added the server's static IP to the hosts file on the clients I've tried monitoring the server's performance to see if anything makes sense. Occasionally the issue coincides with a spike in pages/sec (memory) but not always. Other than that, everything else seems normal. The anti-virus would seem to be the most likely cause to me considering the batch files and what not, but it still hangs when it is completely disabled. I'm at a loss and if anyone can help me with this I'd greatly appreciate it!

    Read the article

  • Why is MySQL table_cache full but never used

    - by Jeremy Clarke
    I have been using the tuning-primer.sh script to tune my my.cnf settings. I have most things working well but the part about TABLE CACHE makes no sense: TABLE CACHE Current table_cache value = 900 tables. You have a total of 0 tables You have 900 open tables. Current table_cache hit rate is 1% , while 100% of your table cache is in use. You should probably increase your table_cache When I do SHOW STATUS; I get the following table-related numbers: Open_tables = 900 Opened_tables = 0 It seems like something is going wrong. I have some extra memory I could use on increasing the table_cache size, but my sense is that the 900 tables already available aren't doing anything, and increasing it will just waste more energy. Why might this be happening? Are there other settings that could cause all my table_cache slots to be used even though there are no hits to them? I have 150 max connections and probably no more than 4 tables per join, FWIW. Here is the tuner script output for temp tables, which I've also been tuning: TEMP TABLES Current max_heap_table_size = 90 M Current tmp_table_size = 90 M Of 11032358 temp tables, 40% were created on disk Perhaps you should increase your tmp_table_size and/or max_heap_table_size to reduce the number of disk-based temporary tables. Note! BLOB and TEXT columns are not allow in memory tables. If you are using these columns raising these values might not impact your ratio of on disk temp tables.

    Read the article

  • sporadic routing to another website when opening a common url

    - by user226098
    I have a strange problem in our office: Sometimes when opening a url from one of our projects random url in any browser not the right website shows up but some other website. In most of the cases it redirects to google.com with some parameters like https://www.google.de/?gfe_rd=cr&ei=krOOU8_kGcSKswadyYDQBw&gws_rd=ssl or just the ugly google 404 page). But today it remains on the origial url but shows up the the content of http://debug.netdna-cdn.com/. This happens about 1 time a week and for no apparent reason. Even stranger it only occurs on a single pc in the network. It now happens on two different computers in the network. Both use windows 8. The problem cannot be fixed by clearing the browser cache but by rebooting the pc or using ipconfig /flushdns. So I think it has something to do with the dns cache of the machine. But I have no idea what the reason is for this and how i can figure out how to solve it. Any ideas?

    Read the article

  • How I can fix the "Display Driver has stopped responding and has recovered"?

    - by Vitor Rangel
    I'm using a GeForce GTX 580, with Windows 7 64-bit. The driver version of the GTX is 301.42. The problem happens after a few minutes, when I'm playing specifc games. It won't happen in all games - And I don't have any idea why these games doesn't work. The games that doesn't work: Battlefield 3, Civilization V, Sniper Elite V2. The games that work: Mass Effect 3, Crysis 2, Team Fortress 2, Left 4 Dead 2, Skyrim, L.A. Noire. As you can see, it's not a problem of "The games that demand more stop working". I've tryed updating the driver of the graphics-card, the bios of the motherboard, even formated my computer (It was needing it) and instaled every driver in the last version possible. This problem happens since I bought my graphics-card, 6 months ago. After a few minutes, from 10 to 20, the pixels in the monitor become strange, with random colors and effects, like it was broken. Then, everything goes black, and the message appears "Display Driver has stopped responding and has recovered". After that, I need to close the game and start again. I am not overclocking, and my temperature never goes higher than 70ºC.

    Read the article

  • ixgbe driver: Limit the max number of cores

    - by Shellex Wai
    I have a Linux workstation with 48 cores and runs ixgbe driver for fiber interface. And I have to test a project name Netmap on it. NetMap is a high performance network framework for high speed interfaces, which has been ported to Linux recently. For some reasons, I must try it on the machine. So I compile it and follow the instructions to run the test problems, but it doesn't work. I check dmesg and it says: [10399.085736] 794.159015 netmap_set_ringid [486] ringid o4o1 set to all 48 HW RINGS [10399.085742] 794.282011 netmap_obj_malloc [220] netmap_if request size 816 too large I asked the author of netmap for help. He told me that I have too many cores in the machine and it should work if I tell ixgbe use less cores (2 to 4 is ok). I am not familiar to driver development and I don't know how to limit the ring numbers by passing arguments to ixgbe driver. So I check the spec from intel's website but found nothing about it. So I come here for more helps. Thank you.

    Read the article

  • Multiple Video Cards - Stuttering

    - by jstawski
    I have two video cards: - XFX PVT84JUDD3 GeForce 8600GT XXX 256MB 128-bit GDDR3 PCI Express x16 SLI Supported Video Card - EVGA 256-P1-N399-LX GeForce 6200 256MB 64-bit GDDR2 PCI Video Card both running the same set of drivers on Windows 7 64-bit. When I work with 2 monitors connected to the 8600GT card everything works smoothly. When I connect the third one to the 6200 then Windows works well and all of a suddon the screens turns black for up to 5 minutes. Then it goes back and at some random interval it goes black again. I can still see the pointer and hit CTRL+ALT+DEL and see the menu to log off, bring the task manager, etc. I've tried changing the 6200 to another PCI slot and the error persists. I've tried connecting 2 monitors only one to each card, same problem. Tried swapping them, mixed and matched the monitors to see if it was a problem with the monitor and my conclusion was that it is not the monitor. The problem also occurred with Vista 64 as well. What could be generating this problem? Can it be the fact that they are different interfaces? Maybe the Motherboard? Should I change something on the BIOS? What do you guys think?

    Read the article

  • Motherboard Dying? AHCI Drive Init and boot loop intermittent failure

    - by Adam Heath
    My computer is now intermittently failing to boot up. For the last couple of days, when I turn it on it hangs on "AHCI Drive Init...", and when powered off and on again, it booted up fine. Today, it did the same but failed in a few other ways too, seemingly at random: Hangs on "AHCI Drive Init..." Boot loop (after "AHCI Drive Init..." appears for a split second (no drives listed)) Black screen (after "AHCI Drive Init..." appears for a split second, a black screen with all fans still running) The interesting part is that the above is not affected by what drives are connected, or what to. I have tried both disks, each disk individually and no disks (along with trying the primary and secondary SATA controllers), none of this has any effect on what happens. After about 20+ attempts of different combinations, it suddenly decided it would boot up into Windows, and I hadn't touched anything for about 2 cycles. Motherboard: Gigabyte GA-870A-USB3 Processor: Amd Phoenom II x6 1090T RAM: 8GB Corsair 1600 Primary Disk: Plextor 128GB SSD Secondary Disk: Western Digital Black 1TB OS: Windows 8.1 Is this my motherboard dying? Or could something else be the cause? Thanks!

    Read the article

  • SQL Server performance on VSphere 4.0

    - by Charles
    We are having a performance issue that we cannot explain with our VMWare environment and I am hoping someone here may be able to help. We have a web application that uses a databases backend. We have an SQL 2005 Cluster setup on Windows 2003 R2 between a physical node and a virtual node. Both physical servers are identical 2950's with 2x Xeaon x5460 Quad Core CPUs and 64GB of memory, 16GB allocated to the OS. We are utilizing an iSCSI San for all cluster disks. The problem is this, when utilizing the application under a repeated stress testing that adds CPUs to the cluster nodes, the Physical node scales from 1 pCPU to 8 pCPUs, meaning we see continued performance increases. When testing the node running Vsphere, we have the expected 12% performance hit for being virtual but we still scale from 1 vCPU to 4 vCPUs like the physical but beyond this performance drops off, by the time we get to 8 vCPUs we are seeing performance numbers worse than at 4 vCPUs. Again, both nodes are configured identically in terms of hardware, Guest OS, SQL Configurations etc and there is no traffic other than the testing on the system. There are no other VMs on the virtual server so there should be no competition for resources. We have contacted VMWare for help but they have not really been any suggesting things like setting SQL Processor Affinity which, while being helpful would have the same net effect on each box and should not change our results in the least. We have looked at all of VMWare's SQL Tuning guides with regards to VSphere with no benefit, please help!

    Read the article

  • Exchange 2003 -- Mailbox Management not deleting ALL messages aged 30 days or older...

    - by tcv
    I've recently created a Mailbox Management task within Exchange 2003 that, every night, looks at the contents of the Deleted Items within a particular mailbox and deletes mail that's 30 days or older. The scheduled task ran on its own last night and I have confirmed that messages within the right mailbox and the right folder were, in fact, processed. Many mails were deleted ... but not never email older than 30 days. In fact, the choice seems kinda random. Last night 3/10/2010 was the 30 day watermark. Mails were deleted from 3/10/2010, sure enough, but not all of them. Mails older than 3/10/2010 were deleted as well, but, again, not all of them. The only criteria I have on the management -- aside from the single mailbox and single folder scopes -- is the age criteria. The size criteria is set to Any, meaning I don't care about the size. I care about the age. It's made me wonder where there is some sort of limit on how many mails can be processed? The schedule is set for 12am and 1am every night. Any hints appreciated.

    Read the article

  • Router reporting failed admin login attempts from home server

    - by jeffora
    I recently noticed in the logs of my home router that it relatively regularly lists the following entry: [admin login failure] from source 192.168.0.160, Monday, June 20,2011 18:13:25 192.168.0.160 is the internal address of my home server, running Windows Home Server 2011. Is there anyway I can find out what specifically is trying to login to the router? Or is there some explanation for this behaviour? (not sure if this belongs here or on superuser...) [Update] I've run both Wireshark and netmon for a while on my home server. Wireshark captured the traffic, but didn't really show anything useful (or nothing I could make use of). A simple HTTP GET request is sent from the server (192.168.0.160) to the router (192.168.0.1), from a seemingly random port (I've seen examples from 50068, 52883), and it appears to do it twice in quick succession (incrementing port by 1), about every hour. Running netstat around the time of the failure didn't show anything (probably too long after anyway). I tried using netmon as it categorises by process, so I thought it might show a corresponding process for the port. Unfortunately, this comes in under the 'unknown' category, meaning it's basically just a slower, less useful Wireshark. I know there's not much to go on here, but does this help in anyway?

    Read the article

  • Queries passed to SQL Server are getting corrupted

    - by adrianbanks
    We are experiencing a bizarre error with our application at a customer site. We have managed to narrow it down to the point where we can replicate the behaviour using just Management Studio and SQL Server. We have two machines, A and B: +------------+ +--------------------+ | [A] | | [B] | | Management | -------------- | SQL Server 2008 R2 | | Studio | | Enterprise x64 | +------------+ +--------------------+ We are running a SQL script in Management Studio on machine A against the SQL Server instance on machine B. We are not actually executing the script, just parsing it. Most of the time, the parse operation works fine. Occasionally (seemingly randomly), the parse operation fails with a syntax error. The error message shows the part of the script with the error, which appears as some SQL from the original script that has been truncated and has random characters appended to it. An example: The original SQL: SELECT DISTINCT ST.TABLE_NAME as TableName FROM INFORMATION_SCHEMA.TABLES AS ST INNER JOIN INFORMATION_SCHEMA.COLUMNS AS SC ON SC.TABLE_NAME = ST.TABLE_NAME WHERE ST.TABLE_TYPE = 'BASE TABLE' AND SC.COLUMN_NAME = 'Identity' AND ST.TABLE_NAME != 'dtproperties' ORDER BY ST.TABLE_NAME The SQL that is in error (as reported by SQL Server): SELECT DISTINCT ST.TABLE_NAME as TableName FROM INFORMATION_SCHEMA.TABLES AS ST INNER JOIN INFORMATION_SCHEMA.COLUMNS AS SC ON SC.TABLE_NAME = Sa? The above example shows how the query is being corrupted. It doesn't always happen, and is not always the same bit of SQL that causes the error. Parsing this script against another SQL Server instance produces no errors, showing that the script is fine. It appears that something is corrupting the SQL that is being received the the server. This leads me to think that the problem lies either with the client end or in the transmission of the SQL from the client to the server. I have a SQL trace from the period where an error occurs, which shows the SQL has been corrupted when SQL Server receives it. We have been unable to track down any possible cause of this behaviour, and so cannot find a fix. Because the errors occur seemingly randomly, it is also very hard to generate reproduction steps to submit a bug report. Any ideas?

    Read the article

  • how to diagnose a hard system seizure? Dell+Ubuntu

    - by rob
    I've got Ubuntu 9.10 on a Dell Vostro 420 desktop, a little over a year old, which I use for plain vanilla work stuff (email, web, terminal, text editor). Every now and then, at totally random times, it completely freezes on me. Hard. Mouse and keyboard stop working, cursor stops blinking, clock stops moving. All I can do is hold down the power button on the front of the box to shut it off. Sometimes it happens after several months of continuous uptime; sometimes it happens a few minutes after a reboot, while all I've done is open a terminal to look at log files, or maybe firefox to do a google search. Each time, there is nothing at all in /var/log/messages at the time of the crash. This makes it seem like a hardware problem, and indeed a few months ago I opened the box and wiggled everything and the problem went away for a while. But now it's back. I went in and checked everything, took out each RAM card and reseated. No luck. I ran all the system diagnostics (the long version) and everything passed with flying colors. Something is messed up in this box, but without any useful logs or failed tests, how in the world am I going to find it? And of course, Dell's not gonna help me cause I went and replaced Windows with Ubuntu. What steps would you take next to track down this problem?

    Read the article

  • All network devices freezing when Airport Extreme Base Station is connected. Any ideas?

    - by Jon
    I've been troubleshooting this issue for a while, and through a series of events have it narrowed down to my airport extreme base station. I like this router, since I'm able to connect to IPV6 sites without any insane configuration (my alternate router is too old and doesn't support v6). My question is: Has anyone else had this issue, if so how is it resolved? If not, can you recommend a good IPv6 router? Here is how I came to the conclusion that it is the router: Devices: XBOX 360, HTC Incredible, Home-Built machine running FreeBSD, Home-Built machine running Ubuntu 10.04. 1.) Noticed freezing on Ubuntu Box. 2.) Noticed freezing on XBOX360 3.) Noticed freezing on HTC Incredible (only when connected to my network wirelessly). The above all happened at random times throughout the past few weeks. Over the last few days, I was playing XBOX and noticed that the XBOX and Ubuntu machines both froze. I picked up my phone, and it was also frozen. I reset all devices, power-cycled my router, and all was fine again. About two hours later, it happened again (I was playing Forza III, the XBOX froze; I went to the Ubuntu box and it was frozen; unfortunately, the HTC phone was not connected wirelessly, and the FreeBSD box was turned off). I can't even begin to imaging what a router could be doing to freeze devices with such differing hardware/software/OS, and I feel absurd for coming to this conclusion, but I have nothing else. I hooked up my archaic Netgear router, and have had no problems since. :(

    Read the article

  • Problems Installing slapd On Ubuntu Server 11.10

    - by Zach Dziura
    I know that there's a Ubuntu-specific StackExchange website, but I thought that I'd ask here because it's a server-specific question. If I'm wrong in my logic... Well, you people are better at this than I am! O=) On with the show! I'm in the process of installing Oracle Database 11g R2 Standard Edition onto Ubuntu Server 11.10. I found a guide on the Oracle Support Forums that walks you through the process fairly easily. Unfortunately, I'm running into issues installing one particular dependency: slapd. When I go to install it, I get this error message: (Reading database ... 64726 files and directories currently installed.) Unpacking slapd (from .../slapd_2.4.25-1.1ubuntu4.1_amd64.deb) ... Processing triggers for man-db ... Processing triggers for ufw ... Processing triggers for ureadahead ... Setting up slapd (2.4.25-1.1ubuntu4.1) ... Usage: slappasswd [options] -c format crypt(3) salt format -g generate random password -h hash password scheme -n omit trailing newline -s secret new password -u generate RFC2307 values (default) -v increase verbosity -T file read file for new password Creating initial configuration... Loading the initial configuration from the ldif file () failed with the following error while running slapadd: str2entry: invalid value for attributeType olcRootPW #0 (syntax 1.3.6.1.4.1.1466.115.121.1.15) slapadd: could not parse entry (line=1051) dpkg: error processing slapd (--configure): subprocess installed post-installation script returned error exit status 1 Errors were encountered while processing: slapd E: Sub-process /usr/bin/dpkg returned an error code (1) After much Google searches and forum trolling, I have yet to find a definitive answer as to what's going wrong. The error messages seem straight forward enough, but I have no idea how to debug this. Can anyone offer some assistance? Again, if I'm asking in the wrong place, I apologize. If I'm indeed asking properly, then thank you for any and all help!

    Read the article

  • Where do vendors publish internal transfer rates of HDDs?

    - by red888
    So I've started to dig into storage fundamentals and found that in order to calculate the IOPS of a HDD you need to know the internal transfer rate of the drive (time it takes data to move from the platters to internal disk's cache). I went on newegg and even a few vendor sites and could not find this info published for any HDDs. Is it sometimes called something else? Take this link to a seagate HDD for instance. Nowhere do I see "internal transfer rate", but I do see something called "Sustained Data Rate OD"- is that the same thing? Just so you know where I'm getting this info (Book: "Information Storage and Management Storing, Managing..."): Consider an example with the following specifications provided for a disk: The average seek time is 5 ms in a random I/O environment; therefore, T = 5 ms. Disk rotation speed of 15,000 revolutions per minute or 250 revolutions per second — from which rotational latency (L) can be determined, which is one-half of the time taken for a full rotation or L = (0.5/250 rps expressed in ms). 40 MB/s internal data transfer rate, from which the internal transfer time (X) is derived based on the block size of the I/O — for example, an I/O with a block size of 32 KB; therefore X = 32 KB/40 MB. Consequently, the time taken by the I/O controller to serve an I/O of block size 32 KB is (TS) = 5 ms + (0.5/250) + 32 KB/40 MB = 7.8 ms. Therefore, the maximum number of I/Os serviced per second or IOPS is (1/TS) = 1/(7.8 × 10^-3) = 128 IOPS.

    Read the article

  • Difficult to point-and-click target with Apple Magic Trackpad?

    - by Andrew Swift
    My Magic Trackpad is great for most things involving dragging and gestures, but for simple point-and-click use it is starting to get really annoying. For example, my bank has a numeric code that I need to enter from a visual grid on the screen, by clicking on the six numbers in order. To do this is quite difficult with the Magic Trackpad. Idea 1: it is because when you start dragging on the touchpad, there is a brief delay before the mouse starts to move. The delay might be enough to screw up my anticipation of where the cursor is going to go. Idea 2: it may have to do with the cursor acceleration. If I move it a little, the cursor moves a little. If I move it a lot, it goes much faster. I have tried various settings in the preference pane, and although the cursor does move more or less quickly, it doesn't seem any more or less easy to hit a given target. As I am writing this post, I tried a brief experiment -- I chose a spot on the page (the bracket in the superuser logo) and tried to move the cursor there in one quick movement. It's extremely difficult, even though I've been using Macs and touchpads since 1999. There is something about the behavior of the trackpad that is making it impossible for me to learn how to accurately predict where the cursor will end up. Does anyone else have this problem?

    Read the article

  • To what extent is size a factor in SSD performance?

    - by artif
    To what extent is the size of an SSD a factor in its performance? In my mind, correct me if I'm wrong, a bigger SSD should be, everything else being equal, faster than a smaller one. A bigger SSD would have more erase blocks and thus more leeway for the FTL (flash translation layer) to do garbage collection optimization. Also there would be more time before TRIM became necessary. I see on Wikipedia that it remarks that "The performance of the SSD can scale with the number of parallel NAND flash chips used in the device" so it seems throughput also increases significantly. Also many SSDs contain internal caches of some sort and presumably those caches are larger for correspondingly large SSDs. But supposing this effect exists, I would like a quantitative analysis. Does throughput increase linearly? How much is garbage collection impacted, if at all? Does latency stay the same? And so on. Would the performance of a 8 GB SSD be significantly different from, for example, an 80 GB SSD assuming both used high quality chips, controllers, etc? Are there any resources (webpages, research papers, presentations, books, etc) that discuss correlations between SSD performance (4 KB random write speed, latency, maximum sequential throughput, etc) and size? I realize this does not really sound like a programming question but it is relevant for what I'm working on (using flash for caching hard drive data) which does involve programming. If there is a better place to ask this question, eg a more hardware oriented site, what would that be? Something like the equivalent of stack overflow (or perhaps a forum) for in-depth questions on hardware interfaces, internals, etc would be appreciated.

    Read the article

  • How to diagnose storage system scaling problems?

    - by Unknown
    We are currently testing the maximum sequential read throughput of a storage system (48 disks total behind two HP P2000 arrays) connected to HP DL580 G7 running RHEL 5 with 128 GB of memory. Initial testing has been mainly done by running DD-commands like this: dd if=/dev/mapper/mpath1 of=/dev/null bs=1M count=3000 In parallel for each disk. However, we have been unable to scale the results from one array (maximum throughput of 1.3 GB/s) to two (almost the same throughput). Each array is connected to a dedicated host bust adapter, so they should not be the bottleneck. The disks are currently in JBOD configuration, so each disk can be addressed directly. I have two questions: Is running multiple DD commands in parallel really a good way to test maximum read throughput? We have noticed very high SWAPIN-% numbers in iotop, which I find hard to explain because the target is /dev/null How shoud we proceed in trying to find the reason for the scaling problem? Do you thing the server itself is the bottleneck here, or could there be some linux parameters that we have overlooked?

    Read the article

  • Internet Troubles - PPPoE vs PPPoA?

    - by AkkA
    I have been having some internet troubles at home (ADSL2+ connection in Australia). We get random drop-outs from the authentication connection. It will keep the connection to the DSL service, but we lose authentication and either have to restart the router/modem (its combined, a Belkin one, not sure on model number) or unplug the phone cable, wait about 30 seconds and plug it in again. I've called the ISP (Telstra) a few times, but they only offer limited support when we dont use their supported hardware. Apparently something had happened on their side, they checked the box again (at least it sounded that simple), and told me it would be fine. It wasnt. I've replaced all the filters around the house, but that didnt help either. We do live a little bit away from the exchange (get a sync speed of about 3000/900), so I thought it could be due to line noise but that hasnt helped. Telstra allow both PPPoE and PPPoA connections (which I'm configuring through my router, dont have software on the PC side). I've been running PPPoA the whole time, would it make any difference changing it to PPPoE? If not, are there any other theories as to why we would be experiencing these drop-outs? It has been fine for at least 12 months, then suddenly started about 2 months ago.

    Read the article

  • vSphere - datastore falling off a host

    - by Chadddada
    Recently we have been running the vCheck powershell script daily in order to help in monitoring our vSphere ESX 4.0 environment. One of the oddities that we have been seeing is that some of the datastores on the SAN don't always show up on every host. Our hosts are connected redundantly, via FC, to some brocade FC switches, which then connect via fiber to our EMC Ax4 SAN. While all the datastores are presented to each host we have, and they see them initially, they sometimes seem to fall off and are no longer visible. It easy enough to rescan for datastores and add them back to the hosts the hosts but this seems to be an error. Has anyone else seen this or know why it may be happening? Responses to questions: 1. Is it always the same ESX servers that lose their connection? – Scott Warren No this happens randomly on random hosts. If a VM is running on a particular host, of which the VM's disks are on a SAN datastore, then that datastore won't disappear. It seems to happen if a host doesn't touch a datastore for a bit and it just forgets about it.

    Read the article

< Previous Page | 353 354 355 356 357 358 359 360 361 362 363 364  | Next Page >