Search Results

Search found 91557 results on 3663 pages for 'server 2008'.

Page 363/3663 | < Previous Page | 359 360 361 362 363 364 365 366 367 368 369 370  | Next Page >

  • Update table without using cursor and on date

    - by Muhammad Kashif Nadeem
    Please copy and run following script DECLARE @Customers TABLE (CustomerId INT) DECLARE @Orders TABLE ( OrderId INT, CustomerId INT, OrderDate DATETIME ) DECLARE @Calls TABLE (CallId INT, CallTime DATETIME, CallToId INT, OrderId INT) ----------------------------------------------------------------- INSERT INTO @Customers SELECT 1 INSERT INTO @Customers SELECT 2 ----------------------------------------------------------------- INSERT INTO @Orders SELECT 10, 1, DATEADD(d, -20, GETDATE()) INSERT INTO @Orders SELECT 11, 1, DATEADD(d, -10, GETDATE()) ----------------------------------------------------------------- INSERT INTO @Calls SELECT 101, DATEADD(d, -19, GETDATE()), 1, NULL INSERT INTO @Calls SELECT 102, DATEADD(d, -17, GETDATE()), 1, NULL INSERT INTO @Calls SELECT 103, DATEADD(d, -9, GETDATE()), 1, NULL INSERT INTO @Calls SELECT 104, DATEADD(d, -6, GETDATE()), 1, NULL INSERT INTO @Calls SELECT 105, DATEADD(d, -5, GETDATE()), 1, NULL ----------------------------------------------------------------- I want to update @Calls table and need following results. I am using the following query UPDATE @Calls SET OrderId = ( CASE WHEN (s.CallTime > e.OrderDate) THEN e.OrderId END ) FROM @Calls s INNER JOIN @Orders e ON s.CallToId = e.CustomerId and the result of my query is not what I need. Requirement: As you can see there are two orders. One is on 2010-12-12 and one is on 2010-12-22. I want to update @Calls table with relevant OrderId with respect to CallTime. In short If subsequent Orders are added, and there are further calls then we assume that a new call is associated with the most recent Order Note: This is sample data so this is not the case that I always have two Orders. There might be 10+ Orders and 100+ calls. Note2 I could not find good title for this question. Please change it if you think of any better. Thanks.

    Read the article

  • Connecting to MSSQL Express in silverlight 4 appl, the db doesn't shows up in Management Studio Expr

    - by Gabriel
    I'm using MSSQLExpress named instance in my Silverlight 4 application. The database located in the web application data folder. I attached the db via VS2010. The program works, but the db doesn't show up in Management Studio Express. If I delete the connection from within VS2010, and Try to attach to db via Management Studio Express, on writes, that the database with same the name already exists. Why the database connected via VS2010 doesn't show up in Management Studio Express? Thanks in advance Gabor

    Read the article

  • Is it a good idea to use a computed column as part of a primary key ?

    - by Brann
    I've got a table defined as : OrderID bigint NOT NULL, IDA varchar(50) NULL, IDB bigint NULL, [ ... 50 other non relevant columns ...] The natural primary key for this table would be (OrderID,IDA,IDB), but this it not possible because IDA and IDB can be null (they can both be null, but they are never both defined at the same time). Right now I've got a unique constraint on those 3 columns. Now, the thing is I need a primary key to enable transactional replication, and I'm faced with two choices : Create an identity column and use it as a primary key Create a non-null computed column C containing either IDA or IDB or '' if both columns were null, and use (OrderID,C) as my primary key. The second alternative seams cleaner as my PK would be meaningful, and is feasible (see msdn link), but since I've never seen this done anywhere, I was wondering if they were some cons to this approach.

    Read the article

  • Is it possible for two VS2008 C# class library projects to share a single namespace?

    - by jeah
    I am trying to share a common namespace between two projects in a single solution. The projects are "Blueprint" and "Repositories". Blueprint contains Interfaces for the entire application and serves as a reference for the application structure. In the Blueprint project, I have an interface with the following declaration: namespace Application.Repositories{ public interface IRepository{ IEntity Get(Guid id); } } In the Repositories project I have a class the following class: namespace Application.Repositories{ public class STDRepository: IRepository { STD Get(Guid id){ return new SkankyExGirlfriendDataContext() .FirstOrDefault<STD>(x=>x.DiseaseId == id); } } } However, this does not work. The Repositories project has a reference to the Blueprint project. I receive a VS error: "The type or namespace name 'IRepository' could not be found (are you missing a using directive or an assembly reference?) - Normally, this is easy to fix but adding a using statement doesn't make sense since they have the same namespace. I tried it anyway and it didn't work. The reference has been added, and without the line of code referencing that interface, both projects compile successfully. I am lost here. I have searched all over and have found nothing, so I am assuming that there is something fundamentally wrong with what I'm doing ... but I don't know what it is. So, I would appreciate some explanation or guidance as to how to fix this problem. I hope you guys can help. Note: The reason I want to do it this way and keep the interfaces under the same namespace is because I want a solid project to keep all the interfaces in, in order to have a reference for the full architecture of the application. I have considered work arounds, such as putting all of the interfaces in the Blueprint.Application namespace instead of the application namespace. However, that would require me to write the using statement on virtually every page in the application...and my fingers get tired. Thanks again guys...

    Read the article

  • Multiple conditions on select query

    - by stats101
    I have a select statement and I wish to calculate the cubic volume based on other values within the table. However I want to check that neither pr.Length_mm or pr.Width_mm or pr.Height_mm are NULL prior. I've looked at CASE statements, however it only seems to evaluate one column at a time. SELECT sa.OrderName, sa.OrderType, pr.Volume_UOM ,pr.Length_mm*pr.Width_mm*pr.Height_mm AS Volume_Cubic ,pr.Length_mm*pr.Width_mm AS Volume_Floor ,pr.Length_mm ,pr.Height_mm ,pr.Width_mm FROM CostToServe_MCB.staging.Sale sa LEFT JOIN staging.Product pr ON sa.ID = pr.ID

    Read the article

  • error C2146: syntax error : missing ';' before identifier 'g_App'

    - by numerical25
    I wish c++, was a little more specific on the messages they give. The following error is being thrown in the document below main.h #ifndef main_h #define main_h //includes #include <windows.h> #include <commctrl.h> #include <d3d9.h> #include <fstream> #include "capplication.h" //constants #define TITLE "D3D Tut 01: Create Window" #define WINDOW_X 350 #define WINDOW_Y 320 //Button ID's #define ID_START 1 #define ID_CANCEL 2 //globals extern CApplication g_App; //function prototypes LRESULT CALLBACK WindowProcedure(HWND,UINT,WPARAM,LPARAM); #endif The only header file that could possible throw this error is the capplication.h. given below capplication.h #ifndef capplication_h #define capplication_h #include"main.h" class CApplication { public: CApplication(void); ~CApplication(void); void InitWindow(void); void SaveSettings(void); void LoadSettings(void); void KillWindow(void); inline bool GetWindowStatus(void) { return m_bRunningWindow; } inline HWND GetWindowHandle(void) { return m_hWindow; } inline void SetWindowStatus(bool bRunningWindow) { m_bRunningWindow = bRunningWindow; } private: bool m_bRunningWindow; HWND m_hWindow, m_hBtnStart, m_hBtnCancel, m_hLblResolution, m_hCbResolution, m_hLblBackBuffer, m_hCbBackBuffer, m_hLblDepthStencil, m_hCbDepthStencil, m_hLblVertexProcessing, m_hCbVertexProcessing, m_hLblMultiSampling, m_hCbMultiSampling, m_hLblAnisotropy, m_hCbAnisotropy; DWORD m_dwWidth, m_dwHeight, m_dwVertexProcessing, m_dwAnisotropy; D3DFORMAT m_ColorFormat, m_DepthStencilFormat; D3DMULTISAMPLE_TYPE m_MultiSampling; }; #endif Besides that, the only suspicious thing I see is fstream given in the first code. I did have it as fstream.h But VC++ was not recognizing it so I was told to remove the h and I did. now I am down to this error. and I have no clue what it could be. Possibly something obvious

    Read the article

  • C# Dataset Dynamically Add DataColumn

    - by Wesley
    I am trying to add a extra column to a dataset after a query has completed. I have a database relationship of the following: Employees / \ Groups EmployeeGroups Empoyees holds all the data for that individual, I'll name the unique key the UserID. Groups holds all the groups that a employee can be a part of, i.e. Super User, Admin, User; etc. I will name the unique key GroupID EmployeeGroups holds all the associations of which groups each employee belongs too. (UserID | GroupID) What I am trying to accomplish is after querying for a all users I want to loop though each user and add what groups that user is a part of by adding a new column to the dataset named 'Groups' which is a string to insert the values of the next query to get all the groups that user is a part of. Then by user of databinding populate a listview with all employees and their group associations My code is as follows; Position 5 is the new column I am trying to add to the dataset. string theQuery = "select UserID, FirstName, LastName, EmployeeID, Active from Employees"; DataSet theEmployeeSet = itsDatabase.runQuery(theQuery); DataColumn theCol = new DataColumn("Groups", typeof(string)); theEmployeeSet.Tables[0].Columns.Add(theCol); foreach (DataRow theRow in theEmployeeSet.Tables[0].Rows) { theRow.ItemArray[5] = "1234"; } At the moment, the code will create the new column but when i assign the data to that column nothing will be assigned, what am I missing? If there is any further explination or information I can provide, please let me know. Thank you all

    Read the article

  • "Error opening associated documents" message when loading VS

    - by kumar
    When loading up a solution in VS2008 I get this message: An error was encountered while opening associated documents the last time this solution was loaded. Document load is being skipped during this solution load in order to avoid that error. It shut down immediately the first time I opened it. The next time I opened it, VS popped up a message box but did not shut down at first; however, it did shut down when I clicked a usercontrol or ASPX page. How can I find which document is causing the problem? Thanks...

    Read the article

  • Visual C++/CLI "An unhandled exception of type 'System.StackOverflowException' occurred in"

    - by JennyWong
    Hi, I have a game I am making, it is giving me this message... "An unhandled exception of type 'System.StackOverflowException' occurred in game.exe" To explain...I have a 2D array with 9 different opening moves and I am getting a random number to use as the array reference to retrieve the details needed for a move... you may get the same move again - but that's illegal. the move may be illegal for other reasons too So to try and fix this, I am calling the function again from within the function. The error occurs very randomly Is this bad practise to call a function from within itself? What would be a better way to randomly row from a 2D array, AND if it isn't accept to get another one.... Or better still, how can I retrieve a random LEGAL move?

    Read the article

  • Crystal Report print functionlity doesn't work after deployment?

    - by Ahmed
    I'm using crystal reports to build reports, everything is ok while development. But after deployment of website, print functionality doesn't work. I use _rptDocument.PrintToPrinter(1, false, 0, 0); to print report. I've tried two methods to deploy website Normal Publish option. Web Deployment Project. But I got the same output, print functionality doesn't work. Also, I tried to set default printer, this also doesn't work. Any ideas?

    Read the article

  • check_ssh executed from Nagios server returns "Server answer: ", nothing else

    - by phs
    Commmand works on the host I need to monitor (its IP is denoted as $HOSTADDRESS$ here): [root@host ~]# /usr/local/nagios/libexec/check_ssh localhost SSH OK - OpenSSH_4.3 (protocol 2.0) However, on the Nagios server, it does not: root@server:~# /usr/lib/nagios/plugins/check_ssh -H $HOSTADDRESS$ Server answer: I can see that the port is open: root@server:~# /usr/lib/nagios/plugins/check_tcp -H $HOSTADDRESS$ -p 22 TCP OK - 0.123 second response time on port 22|time=0.123277s;;;0.000000;10.000000 And I can verify with telnet: root@server:/etc/nagios3/conf.d# telnet $HOSTADDRESS$ 22 Trying $HOSTADDRESS$... Connected to $HOSTADDRESS$. Escape character is '^]'. After searching the web for two hours and trying different suggestions I am out of ideas. I have several other hosts with similar setup, and they don't have this problem. I have compared the configs and they look the same (I think). I am clearly missing something here.

    Read the article

  • Visual Studio - how to create two projects using the same sources

    - by mack369
    My solution consists of 2 executable projects and a couple dlls. Project1 is a Smart Device Project, Project2 is a Windows Forms Project. Both projects use the same libraries, the reason of that is I want to test my libraries on PC before I deploy it on the device. The problem is that the DLL project type can be Smart Device Class Library or Class Library, not both. I cannot add a reference from SD project to WF and vice versa. I was able to add reference from SD project to a dll file (generated from Class Library project) instead of the project itself, but for some reason I got the message "cannot load XXX type from YYY assembly". It doesn't depend on my code, because when I created separate project for the same sources, everything was fine. The only solution I've found is to create 2 types of projects for each library, but I don't know how to make 2 projects based on the same sources.

    Read the article

  • vs2008, opencv2.1,compile error in cxcore.hpp

    - by Long Gu
    Hi, gurus: I installed opencv2.1, made a new project (proj_A) using vs2008, used it for my computer vision tasks, it works fine. I copied an old project (proj_B, also made using vs2008) from other PC, compile it with ".h" and ".lib" files copied from opencv1.0 (which I did not install onto my PC), it compiles fine. I re-directed ".h" and ".lib" files in proj_B to opencv2.1 folders instead, compiled the proj_B, and then I got these errors from cxcore.hpp: class CV_EXPORTS RNG { public: enum { A=4164903690U, UNIFORM=0, NORMAL=1 }; // errors here, line 936 errors are: 5c:\opencv2.1\include\opencv\cxcore.hpp(936) : error C2143: syntax error : missing '}' before 'constant' 5c:\opencv2.1\include\opencv\cxcore.hpp(936) : error C2059: syntax error : 'constant' 5c:\opencv2.1\include\opencv\cxcore.hpp(936) : error C2143: syntax error : missing ';' before '}' 5c:\opencv2.1\include\opencv\cxcore.hpp(936) : error C2238: unexpected token(s) preceding ';' (400+ similar errors, but I believe the answer should be the same, so only list 1 set here) I compared setting for proj_A and proj_B, made them identical, and find no improvement. proj_A works well, proj_B refuse to compile. May I know what's wrong? Urgent, need to get it solved ASAP! Thanks a lot!

    Read the article

  • What is the best practice to segment c#.net projects based on a single base project

    - by Anthony
    Honestly, I can't word my question any better without describing it. I have a base project (with all its glory, dlls, resources etc) which is a CMS. I need to use this project as a base for othe custom bake projects. This base project is to be maintained and updated among all custom bake projects. I use subversion (Collabnet and Tortise SVN) I have two questions: 1 - Can I use subversion to share the base project among other projects What I mean here is can I "Checkout" the base project into another "Checked Out" project and have both update and commit seperatley. So, to paint a picture, let's say I am working on a custom project and I modify the core/base prject in some way (which I know will suit the others) can I then commit those changes and upon doing so when I update the base project in the other "Checked out" resources will it pull the changes? In short, I would like not to have to manually deploy updated core files whenever I make changes into each seperate project. 2 - If I create a custom file (let's say an webcontrol or aspx page etc) can I have it compile seperatley from the base project Another tricky one to explain. When I publish my web application it creates DLLs based on the namespaces of projects attached to it. So I may have a number of DLLs including the "Website's" namespace DLL, which could simply be website. I want to be able to make a seperate, custom, control which does not compile into those DLLs as the custom files should not rely on those DLLS to run. Is it as simple to set a seperate namespace for those files like CustomFiles.ProjectName for example? Think of the whole idea as adding modules to the .NET project, I don't want the module's code in any of the core DLLs but I do need for module to be able to access the core dlls. (There is no need for the core project to access the module code as it should be one way only in theory, though I reckon it woould not be possible anyway without using JSON/SOAP or something like that, maybe I am wrong.) I want to create a pluggable environment much like that of Joomla/Wordpress as since PHP generally doesn't have to be compiled first I see this is the reason why all this is possible/easy. The idea is to allow pluggable themes, modules etc etc. (I haven't tried simply adding .NET themes after compile/publish but I am assuming this is possible anyway? OR does the compiler need to reference items in the files?)

    Read the article

  • what is a virtual adapter

    - by numerical25
    I hear the term virtual adapter from time to time. But not exactly sure what it is. I can't exactly find a good definition online. Is there an exact definition for a virtual adapter. If so, what is it. Or what does it usually mean ?

    Read the article

  • June 2013 release of SSDT contains a minor bug that you should be aware of

    - by jamiet
    I have discovered what seems, to me, like a bug in the June 2013 release of SSDT and given the problems that it created yesterday on my current gig I thought it prudent to write this blog post to inform people of it. I’ve built a very simple SSDT project to reproduce the problem that has just two tables, [Table1] and [Table2], and also a procedure [Procedure1]: The two tables have exactly the same definition, both a have a single column called [Id] of type integer. CREATE TABLE [dbo].[Table1] (     [Id] INT NOT NULL PRIMARY KEY ) My stored procedure simply joins the two together, orders them by the column used in the join predicate, and returns the results: CREATE PROCEDURE [dbo].[Procedure1] AS     SELECT t1.*     FROM    Table1 t1     INNER JOIN Table2 t2         ON    t1.Id = t2.Id     ORDER BY Id Now if I create those three objects manually and then execute the stored procedure, it works fine: So we know that the code works. Unfortunately, SSDT thinks that there is an error here: The text of that error is: Procedure: [dbo].[Procedure1] contains an unresolved reference to an object. Either the object does not exist or the reference is ambiguous because it could refer to any of the following objects: [dbo].[Table1].[Id] or [dbo].[Table2].[Id]. Its complaining that the [Id] field in the ORDER BY clause is ambiguous. Now you may well be thinking at this point “OK, just stick a table alias into the ORDER BY predicate and everything will be fine!” Well that’s true, but there’s a bigger problem here. One of the developers at my current client installed this drop of SSDT and all of a sudden all the builds started failing on his machine – he had errors left right and centre because, as it transpires, we have a fair bit of code that exhibits this scenario.  Worse, previous installations of SSDT do not flag this code as erroneous and therein lies the rub. We immediately had a mass panic where we had to run around the department to our developers (of which there are many) ensuring that none of them should upgrade their SSDT installation if they wanted to carry on being productive for the rest of the day. Also bear in mind that as soon as a new drop of SSDT comes out then the previous version is instantly unavailable so rolling back is going to be impossible unless you have created an administrative install of SSDT for that previous version. Just thought you should know! In the grand schema of things this isn’t a big deal as the bug can be worked around with a simple code modification but forewarned is forearmed so they say! Last thing to say, if you want to know which version of SSDT you are running check my blog post Which version of SSDT Database Projects do I have installed? @Jamiet

    Read the article

  • Create a dynamic control and AddHandle WITH Values/Brackets

    - by Jacob Kofoed
    Hi, it seems that adding for example a button Dim myButton as New Button and then addHandler to mySub("lol", 255) is not possible. Where mySub is Shared Sub MySub(byRef myString as string, myInteger as Integer) So: addHandler myButton.click, addressOf mySub("lol", 255) - returns an error saying it does not work with parentheses or whatever. I somehow see why this might not be possible, so I'm looking for a work-around on this problem. Please help _jakeCake

    Read the article

  • Why is my class method not visible when I implement an interface in my class?

    - by Phsika
    i can not see MyLoad.TreeLoader(.... but why i can not see? i implemented iloader to TreeViewLoad. i should see TreeLoader why? namespace Rekursive { public partial class Form1 : Form { public Form1() { InitializeComponent(); } private void Form1_Load(object sender, EventArgs e) { //treeView1.Nodes.Add("Test"); iloader MyLoad = new TreeViewLoad(); MyLoad.loader("test", treeView1, 1); // i can not see MyLoad.TreeLoader(.... but why i can not see? // i implemented iloader to TreeViewLoad. i should see TreeLoader why? //TreeViewLoad myloader = new TreeViewLoad(); } } interface iloader { void loader(string nodeName, TreeView myTre, int id); } class TreeViewLoad : iloader { public void TreeLoader(TreeView tre) { // i will call loader... } public void loader(string nodeName, TreeView myTre, int id) { myTre.Nodes.Add(nodeName + id.ToString()); if (id

    Read the article

< Previous Page | 359 360 361 362 363 364 365 366 367 368 369 370  | Next Page >