Search Results

Search found 39406 results on 1577 pages for 'two legged'.

Page 381/1577 | < Previous Page | 377 378 379 380 381 382 383 384 385 386 387 388  | Next Page >

  • RPM issues after signing JDK 1.6 64-bit

    - by organicveggie
    I'm trying to sign the Java JDK 1.6u21 64-bit RPM on CentOS 5.5 for use with Spacewalk and I'm running into problems. It seems to sign okay, but then when I check the signature it seems to be missing the key I just used to sign it. Yet RPM shows the key in it's list... # rpm --addsign jdk-6u21-linux-amd64.rpm Enter pass phrase: Pass phrase is good. jdk-6u21-linux-amd64.rpm: gpg: WARNING: standard input reopened gpg: WARNING: standard input reopened # rpm --checksig -v jdk-6u21-linux-amd64.rpm jdk-6u21-linux-amd64.rpm: Header V3 DSA signature: NOKEY, key ID ecfd98a5 MD5 digest: OK (650e0961e20d4a44169b68e8f4a1691b) V3 DSA signature: OK, key ID ecfd98a5 Yet I have the key imported (edited for privacy): # rpm -qa gpg-pubkey* |grep ecfd98a5 gpg-pubkey-ecfd98a5-4caa4a4c # rpm -qi gpg-pubkey-ecfd98a5-4caa4a4c Name : gpg-pubkey Relocations: (not relocatable) Version : ecfd98a5 Vendor: (none) Release : 4caa4a4c Build Date: Mon 04 Oct 2010 10:20:49 PM CDT Install Date: Mon 04 Oct 2010 10:20:49 PM CDT Build Host: localhost Group : Public Keys Source RPM: (none) Size : 0 License: pubkey Signature : (none) Summary : gpg(FirstName LastName <[email protected]>) Description : -----BEGIN PGP PUBLIC KEY BLOCK----- Version: rpm-4.4.2.3 (NSS-3) ...key goes here... =gKjN-----END PGP PUBLIC KEY BLOCK----- And I'm definitely running a 64-bit version of CentOS: # uname -a Linux spacewalk.mycompany.corp 2.6.18-194.11.4.el5 #1 SMP Tue Sep 21 05:04:09 EDT 2010 x86_64 x86_64 x86_64 GNU/Linux Without a valid signature, Spacewalk refuses to install the RPM unless I completely disable signature checking. I have tried this with two different keys and two different users on the same machine without any success. Any bright ideas?

    Read the article

  • Probability of Blade Chassis Failure

    - by ChrisZZ
    In my organisation we are thinking about buying blade servers - instead of rack servers. Of course technology vendors also make them sound very nice. A concern, that I read very often in different forums, is, that there is a theoretical possibility of the server chassis going down - which would in consequence take all the blades down. That is due to shared infrastructure. My reaction on this probability would be to have redundancy and by two chassis instead of one (very costly of course). Some people (including e.g. HP Vendors) try to convince us, that the chassis is very very unlikely to fail, due to many redundancies (redundant power supply, etc.). Another concern on my side is, that if something goes down, spare parts might be required - which is difficult in our location (Ethiopia). So I would ask to experienced administrators, that have managed blade server: What is your experience? Do they go down as a whole - and what is the sensible shared infrastructure, that might fail? That question could be extended to shared storage. Again I would say, that we need two storage units instead of only one - and again the vendors say, that this things are so rock solid, that no failure is expected. Well - I can hardly believe, that such a critical infrastructure can be very reliable without redundancy - but maybe you can tell me, whether you have successfull blade-based projects, that work without redundancy in its core parts (chassis, storage...) At the moment, we look at HP - as IBM looks much to expensive... thanks a lot best regards Christian

    Read the article

  • Multiple IP's using one NIC connectivity problem - Windows

    - by Vincent
    I have a frame relay network that is directly connected to a GPRS network. I also have a ADSL high speed network and recently I have been trying to achieve the following network configuration using windows 7 (Also tried XP) with no success to date. On one server I have two NIC's NIC1 I would like the following two static IP address's 10.0.1.110 and 10.0.1.200 the cisco router has a default gateway of 10.0.1.1 the ADSL is DHCP. NIC1 and the cisco router do not have access to the internet. NIC2 is setup for DHCP with a primary DNS and secondary DNS configured to enable internet connectivity. With NIC1 all incoming TCP connections are from IP address's starting with 10.192.x.x I cannot establish a TCP connection to both 10.0.1.110 and 10.0.1.200. Its either one or the other. I have a static route implemented in windows of: route -p 10.192.0.0 mask 255.255.0.0 10.0.1.1 metric 1 I have tried leaving out the gateway in the NIC1 and many other combinations with no success. Can anyone please help? What am I doing wrong?

    Read the article

  • Tcpreplaying using VMware

    - by Methos
    This is more like a testbed setup question. I want to use VMware to debug some networking code in the linux kernel in the VM. My VM has two network interfaces. What I want to do is replay the capture file in the host and receive the packets in the VM. My problem is I do not see replayed packets in the VM. I am running VMware and tcpreplay on the host as sudo. Hence I think there should not be any problem access devices files. I am running VMware workstation 7.0 a. I first began with Custom networking as that provides option of creating your own virtual network name. I wrote /dev/vmnet3 and /dev/vmnet4 for the two interfaces respectively. However, after booting the guest, I did not see any of these interfaces or devices files (in /dev) created on the host. b. Then I tried 'Host Only', but that does not show what bridge/device file is associated with the interface. c. Finally I tried bridged networking mode. I see vmnet1, vmnet8 and vboxnet0 on the host. I have tcpreplayed the capture file on each of these interfaces, for all the above three cases. I tried to capture packets in the VM using "tcpdump -i any". However, I do not see any packets. Any ideas/pointers?

    Read the article

  • CNAME redirect to Wordpress blog not working (.htaccess problem)

    - by Vincent Chan
    I have two domains hosting in two different servers: domain1.com & domain2.com I would like to forward "blog.domain1.com" to "blog2.domain2.com" which is a Wordpress blog using CNAME redirect. Before I installed Wordpress. blog.domain1.com (=redirect=) blog2.domain2.com/index.htm (working fine) The browser will keep the URL (http://blog.domain1.com) even the index.htm is on domain2.com server. However, after I installed Wordpress, the browser will change the URL to (http://blog2.domain2.com) This is my current setup: On domain1.com DNS: blog.domain1.com CNAME redirect to domain2.com on domain2.com .htaccess: Options +FollowSymLinks RewriteEngine On RewriteCond %{HTTP_HOST} ^blog\.domain1\.com RewriteRule ^(.*)$ http://blog2.domain2.com/$1 [R=301,L] on blog2.domain2.com .htaccess: DirectoryIndex index.php <IfModule mod_rewrite.c> Options +FollowSymLinks RewriteEngine On RewriteBase /blog2/ RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /blog2/index.php [L] </IfModule> blog2.domain2.com is installed under domain2.com/blog2/ All I want to do is keeping the URL (blog.domain1.com) unchanged for the whole Wordpress redirect. Thanks a lot.

    Read the article

  • Which is the fastest way to move 1Petabyte from one storage to a new one?

    - by marc.riera
    First of all, thanks for reading, and sorry for asking something related to my job. I understand that this is something that I should solve by myself but as you will see its something a bit difficult. A small description: Now Storage = 1PB using DDN S2A9900 storage for the OSTs, 4 OSS , 10 GigE network. (lustre 1.6) 100 compute nodes with 2x Infiniband 1 infiniband switch with 36 ports After Storage = Previous storage + another 1PB using DDN S2A 990 or LSI E5400 (still to decide) (lustre 2.0) 8 OSS , 10GigE network 100 compute nodes with 2x Infiniband Previous experience: transfered 120 TB in less than 3 days using following command: tar -C /old --record-size 2048 -b 2048 -cf - dir | tar -C /new --record-size 2048 -b 2048 -xvf - 2>&1 | tee /tmp/dir.log So , big problem here, using big mathematical equations I conclude that we are going to need 1 month to transfer the data from one side to the new one. During this time the researchers will need to step back, and I'm personally not happy with this. I'm telling you that we have infiniband connections because I think that may be there is a chance to use it to transfer the data using 18 compute nodes (18 * 2 IB = 36 ports) to transfer the data from one storage to the other. I'm trying to figure out if the IB switch will handle all the traffic but in case it just burn up will go faster than using 10GigE. Also, having lustre 1.6 and 2.0 agents on same server works quite well, with this there is no need to go by 1.8 to upgrade the metadata servers with two steps. Any ideas? Many thanks Note 1: Zoredache, we can divide it in two blocks (A)600Tb and (B)400Tb. The idea is to move (A) to new storage which is lustre2.0 formated, then format where (A) was with lustre2.0 and move (B) to this lustre2.0 block and extend with the space where (B) was. This way we will end with (A) and (B) on separate filesystems, with 1PB each.

    Read the article

  • vyatta Server Reboots by itself

    - by Fernando
    I have an issue regarding some hardware, maybe you can help me. First, I set up a Supermicro Superserver SYS-5016I-NTF with a Intel Xeon X3470 and 4 GB of Ram with a Hotlava Card Tambora 64G4 with Intel Chipset 82599EB and 4x10G SPF+ ports. Installed Vyatta community edition 6.3. I used it as router making BGP connections with 2 operators. No load at all, temp ranges normal. But the issue is that it reboots by itself in a ramdom way. Not very often, once every few days. But it is unacceptable for production purposes. So I try to test on different hardware, and installed Vyatta community edition 6.3 on a Dell PowerEdge 2950, with Xeon(R) E5345 @ 2.33GHz and 4 GB of Ram. Same Vyatta configuration as Supermicro Server. With same hotlava Card model ( I bought two of them ) Well I have reboots with this equipment as well. Same frecuency as above. I have checked syslog no strange logs until boot process starts to be logged. So it seems server reboot suddenly. I have installed latest driver for the chipset of the Hotlava card. Servers are placed in a datacenter with UPS So finally two things in common in both servers: Hotlava Card. Someone with issues with this card, or the chipset?? Could be it this card?? Vyatta 6.3 community edition. I don't thing is the problem. Is a regular Debian with packages to glue together different services. Or maybe is something I am missing. Andy ideas, suggestions?? Thank you very much... Fernando

    Read the article

  • Rewriting html links with modproxyperlhtml

    - by Juancho
    I'm trying to setup an Apache reverse proxy using mod_proxy and modproxyperlhtml. This is my scenario: Domain for the proxy: http : // www.myserver.com/ Destination server (the one behind the proxy): http : // myserver.foo.com/myapp/ I'm sorry that I have to space the URL but serverfault doesn't allow me to post more than two links as "spam protection mechanism" (ridiculous on a site where you ask questions about servers and it's really probable to post more than two times the same URL's to explain your question). The idea is to map http : // www.myserver.com/ to http : // myserver.foo.com/myapp/ . Note that the path on the proxy is / and on the destination server is /myapp/. All of the examples I can find on the net (like the one on the official documentation of modproxyperlhtml) are the other way around, ie. path on the proxy /myapp/ and path on the destination server /. This is my current config that doesn't work: ProxyPass / http : // myserver.foo.com/myapp/ ProxyPassReverse / http : // myserver.foo.com/myapp/ PerlInputFilterHandler Apache2::ModProxyPerlHtml PerlOutputFilterHandler Apache2::ModProxyPerlHtml SetHandler perl-script PerlSetVar ProxyHTMLVerbose "On" LogLevel Info <Location / > # ProxyPassReverse /myapp/ PerlAddVar ProxyHTMLURLMap "/myapp/ /" PerlAddVar ProxyHTMLURLMap "http : // myserver.foo.com /" </Location> The examples use the ProxyPassReverse inside the Location directive, but on my case doesn't work, only when outside. With this configuration the links aren't being replaced as they should be, my guess is that the location isn't being found, thus the rewrite rules aren't being applied. The error log only shows that it uncompresses the content, searches it but doesn't find anything: [Tue Nov 13 0842:05 2012] [warn] [ModProxyPerlHtml] Uncompressing text/html; charset=UTF-8, Content-Encoding: gzip\n [Tue Nov 13 08:42:05 2012] [warn] [ModProxyPerlHtml] Content-type 'text/html; charset=UTF-8' match: /(text\\/javascript|text\\/html|text\\/css|text\\/xml|application\\/.*javascript|application\\/.*xml)/is\n [Tue Nov 13 08:42:05 2012] [warn] [ModProxyPerlHtml] Compressing output as Content-Encoding: gzip\n [Tue Nov 13 08:42:06 2012] [warn] [ModProxyPerlHtml] Content-type 'text/html; charset=UTF-8' match: /(text\\/javascript|text\\/html|text\\/css|text\\/xml|application\\/.*javascript|application\\/.*xml)/is\n What could be wrong ?

    Read the article

  • Microsoft Application Request Routing with Windows Authentication

    - by theplatz
    I'm running into a problem trying to get Windows Authentication working in an environment that uses Microsoft Application Request Routing and was hoping someone might be able to help. The problem I'm running into is that only some requests are authenticated, while others fail with 401 errors. I have followed the Special Case of Running IIS 7.0 in a Web Farm instructions found at http://blogs.msdn.com/b/webtopics/archive/2009/01/19/service-principal-name-spn-checklist-for-kerberos-authentication-with-iis-7-0.aspx to no avail. My current server setup looks like the following: ARR Two servers set up with IIS shared configuration using IIS 7.5 on Windows 2008 R2 Anonymous authentication turned on for the Default Web Site Web Farm Two servers running IIS 7.5 on Windows 2008 R2 Three web sites set up using port binding to differentiate between virtual hosts. Ports being used are 8000, 8001, and 8002 Application pools for Windows Authentication all use a common domain account SPN added to domain account for http/<virthalhost-name>:<port-number> and http/<virtualhost-name>.<fully-qualified-domain>:<port-number> The IIS logs show the following when authentication is working/failing. If I understand correctly, all requests should show DOMAIN\User_Name: 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/stylesheets/techweb.landing.css - 8002 DOMAIN\User_Name ARR-HOST-1-IP-ADDRESS 200 0 0 62 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/images/user-background-right.gif - 8002 - ARR-HOST-1-IP-ADDRESS 401 2 5 0 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/images/user-background-left.gif - 8002 DOMAIN\User_Name ARR-HOST-IP-ADDRESS 200 0 0 31 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/images/user-icon.png - 8002 - ARR-HOST-1-IP-ADDRESS 401 2 5 0 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/images/user-icon.png - 8002 - ARR-HOST-1-IP-ADDRESS 401 1 2148074248 0 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/images/application-icon.png - 8002 - ARR-HOST-1-IP-ADDRESS 401 1 2148074248 0 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/images/user-background-right.gif - 8002 - ARR-HOST-1-IP-ADDRESS 401 1 3221225581 15 2012-11-19 15:03:17 CLUSTER-IP-ADDRESS GET /home/images/building.gif - 8002 DOMAIN\User_Name ARR-HOST-2-IP-ADDRESS 200 0 0 218 Does anyone know what might cause this problem and how I can resolve it?

    Read the article

  • Install a KVM guest with LVM partitioning on an LVM partitioned host using virt-install fails, volume group already exists

    - by Rilik84
    our setup consists of a ubuntu 10.04 kvm host server with LVM, on top of which we install the ubuntu 10.04 virtual machines via virt-install and preseed. Each VM has a dedicated logical volume which we pass to virt-install via the "--disk path=/dev/sysvg/vm-name" parameter. The virtual machines themselves are using LVM as well. Virt-install seems to have a few issues with this setup. Say we want to install two virtual machines in parallel. The first vm installs correctly while the second halts during the partitioning, complaining with this error: "volume group name already in use". I tried removing the logical volumes, recreated them, rebooted the kvm host to clear any leftovers but the issue perists. The preseed is telling the vms to create a volume group named "sysvg", which is the same name used by the volume group of the kvm host. Considering this I did another test: I got rid of the preseed part taking care of the partitioning/lvm creation and started the creation of two vms in parallel. If, when prompted, I instruct the vms' installer to do a guided partitioning of the disk with LVM, it will still fail giving this different error on both the vms: Physical Volume /dev/sda5 is already in volume group sysvg. As I wrote, sysvg is the volume group used by the KVM host. So I thought the name clashing was the issue. By removing the preseed part I skipped the volume group naming. I can't understand how the virtual machines would be aware of the presence of that volume group since they're supposed to be isolated from it, especially after I removed and recreated the logical volumes dedicated to them. That detail should not be exposed at all to them! Thanks for the help. I'm clueless.

    Read the article

  • Domain names timing out after VPS IP change

    - by Fourjays
    I rent a CentOS 5 VPS from a UK-based provider, with DirectAdmin also installed. On Thursday night, they carried out planned maintenance to changed the two IPs I had been assigned to two new ones. On Friday, after the change had taken place, I updated my domain name records to reflect the IP change. Since then, all of the domains pointing to the VPS are timing out. Additionally, DirectAdmin was also not responding, but was was resolved by running the ipswap scripts as found in the DirectAdmin knowledgebase. It did not fix my domains though. I have contacted the VPS provider but I have been waiting for a response for some time now. I have checked again, and again, and all the IPs referenced in DirectAdmin are correct. If I go to the server IP in my browser it responds with "Apache is functioning normally." Email accounts on the server are also functioning correctly. But if I access a domain itself, it times out. Running a ping and a DNS look-up, I can confirm the nameserver IPs are correct. If I run a trace route it reaches an IP that is similar to my VPS IPs (last 2 blocks are different) before timing out (it never shows my server IP). I am relatively new to VPS management so don't have a vast wealth of experience with troubleshooting problems on them. I have checked all of the httpd configuration files, which don't seem to have any IP references in them at all. Looking in the Apache error logs, what errors there are do not coincide with times I have tried to access the site. Is this issue at my provider's end? Is there anything else I can check or test, to rule out post-IP-change problems with my server configuration? It was all running fine prior to the IP change.

    Read the article

  • Optimizing Disk I/O & RAID on Windows SQL Server 2005

    - by David
    I've been monitoring our SQL server for a while, and have noticed that I/O hits 100% every so often using Task Manager and Perfmon. I have normally been able to correlate this spike with SUSPENDED processes in SQL Server Management when I execute "exec sp_who2". The RAID controller is controlled by LSI MegaRAID Storage Manager. We have the following setup: System Drive (Windows) on RAID 1 with two 280GB drives SQL is on a RAID 10 (2 mirroed drives of 280GB in two different spans) This is a database that is hammered during the day, but is pretty inactive at night. The DB size is currently about 13GB, and is used by approximately 200 (and growing) users a day. I have a couple of ideas I'm toying around with: Checking for Indexes & reindexing some tables Adding an additional RAID 1 (with 2 new, smaller, HDs) and moving the SQL's Log Data File (LDF) onto the new RAID. For #2, my question is this: Would we really be increasing disk performance (IO) by moving data off of the RAID 10 onto a RAID 1? RAID 10 obviously has better performance than RAID 1. Furthermore, SQL must write to the transaction logs before writing to the database. But on the flip side, we'll be reducing both the size of the disks as well as the amount of data written to the RAID 10, which is where all of the "meat" is - thereby increasing that RAID's performance for read requests. Is there any way to find out what our current limiting factor is? (The drives vs. the RAID Controller)? If the limiting factor is the drives, then maybe adding the additional RAID 1 makes sense. But if the limiting factor is the Controller itself, then I think we're approaching this thing wrong. Finally, are we just wasting our time? Should we instead be focusing our efforts towards #1 (reindexing tables, reducing network latency where possible, etc...)?

    Read the article

  • Sharp mx2600 driver cannot see all the paper trays

    - by Frank R
    I am wondering if someone might have experienced this problem and have a solution. I have just taken over a network about a month ago so it is hard to know what truly worked and didn't work. However the end users reported that they used to be able to choose the tray they wanted to print from in the printer preferences in the driver for the Sharp MX2600n device then send the print job. Now they only have two trays to choose from instead of the four trays that exist. The only thing I have changed that might relate to this network device is the Admin password on the domain controller. I haven't made any changes to the Sharp device or the driver, until recently when I tired to update the driver for this device but that didn't fix anything. The domain controller is a Server 2008 VM running in Hyper-visor and it is pushing the shared printer out to the domain. I have looked at the web interface to manage the device and I can see all four paper trays in there, however if I try to see the number of trays from the driver interface, I can only see the top two paper trays and there should be four of them. This is the same with the admin account on the server or a workstation inside the domain, also a standard user account see's the same result. I have even tried updating the tray status within the driver to show more trays, but that doesn't help. I am hoping there is someone out there that has experienced this problem and knows a solution.

    Read the article

  • Nginx and automatic updates

    - by Desmond Hume
    I'm on Ubuntu 12.04.1 with unattended-upgrades configured for automatic security updates, and I installed Nginx by first adding deb http://nginx.org/packages/ubuntu/ lucid nginx deb-src http://nginx.org/packages/ubuntu/ lucid nginx to /etc/apt/sources.list file, just as was suggested by the official wiki, and then by sudo apt-get update sudo apt-get install nginx which installed Nginx with all the standard modules. But now I think I could make good use of one or two of the Nginx optional modules, like the gzip precompression module or some security-related one. So far, I see two ways of adding an optional module to Nginx, one is compiling and installing from the source code and the other is described in this article. So, which of the ways should I choose so that automatic updates still run for and apply to Nginx and its optional modules? Or should I create a cron job with a command/script specific for Nginx instead of using unattended-upgrades utility? Can I choose between volume updates and security-only updates to be automatically applied to the standard and optional modules? And finally, is there a possibility to automatically update Nginx's modules on the fly (without any connections having been dropped), like the documentation suggests it's possible with sudo kill -USR2 $( cat /run/nginx.pid ) P.S. Actually I'm not certain if unattended-upgrades utility would automatically update the standard modules in the first place, not enough time has passed since Nginx was installed to say for sure.

    Read the article

  • SLI Video Cards

    - by Scott
    I'm configuring a new desktop. I'm looking through all PCI Express 2.0 x16 video cards on NewEgg at the moment. All cards seem to be stating that they have SLI Support or CrossFireX support. I know that these 2 technologies enable you to connect more than one video card together to create more of a powerful video experience. These cards that have this support seem to be more expensive that other cards though. When I did a NewEgg search for cards that did NOT have these two supports, no matches came up for PCI Express 2.0 x16 (haven't checked other interfaces yet though). Can you run an SLI/CrossFireX card as a single card (and if you can is it efficient or even good?), or do you need to have more than one card to run them? Also, do they make cards without these two technologies anymore, and are they even cheaper at this point? I really have no need for SLI/CrossFireX at all, so I was wondering what I should look into. Do cards without this technology not run on the PCI Express 2.0 x16 interface? Thanks ahead of time for all your help.

    Read the article

  • SLI Video Cards

    - by Scott
    I'm configuring a new desktop. I'm looking through all PCI Express 2.0 x16 video cards on NewEgg at the moment. All cards seem to be stating that they have SLI Support or CrossFireX support. I know that these 2 technologies enable you to connect more than one video card together to create more of a powerful video experience. These cards that have this support seem to be more expensive that other cards though. When I did a NewEgg search for cards that did NOT have these two supports, no matches came up for PCI Express 2.0 x16 (haven't checked other interfaces yet though). Can you run an SLI/CrossFireX card as a single card (and if you can is it efficient or even good?), or do you need to have more than one card to run them? Also, do they make cards without these two technologies anymore, and are they even cheaper at this point? I really have no need for SLI/CrossFireX at all, so I was wondering what I should look into. Do cards without this technology not run on the PCI Express 2.0 x16 interface? Thanks ahead of time for all your help.

    Read the article

  • Adding third disk as a single disk in a server with an existing RAID1

    - by slowhandsolo
    I've got a ProLiant DL360 G5 server (Fedora 13) with two SAS disks in a hardware RAID 1, working fine. Now I hot plugged another SAS disk. I'd like to configure this new hard disk out of my RAID, as a single non-RAID disk (ex. /dev/sdb). Even after rebooting the server, I can't see the new disk with "fdisk -l". It displays only my hardware RAID, but not the new disk. [root@myserver]# fdisk -l Disco /dev/cciss/c0d0: 300.0 GB, 299966445568 bytes Disposit. Inicio Comienzo Fin Bloques Id Sistema /dev/cciss/c0d0p1 * 1 126 512000 83 Linux /dev/cciss/c0d0p2 126 71798 292422656 8e Linux LVM Disco /dev/dm-0: 234.9 GB, 234881024000 bytes Disco /dev/dm-1: 10.5 GB, 10536091648 bytes Disco /dev/dm-2: 21.0 GB, 20971520000 bytes Disco /dev/dm-3: 31.5 GB, 31474057216 bytes Disco /dev/dm-4: 1577 MB, 1577058304 bytes However, I can see the new disk using the HP Array Configuration Utility CLI for Linux "hpacucli": [root@myserver]# hpacucli => controller slot=0 physicaldrive all show status physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 300 GB): OK physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 300 GB): OK physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 300 GB): OK => controller slot=0 pd all show detail Smart Array P400i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 **unassigned** physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: **Unassigned Drive** As you can see, I've got two SAS disks in a RAID 1 and the new disk as "unassigned". Is there any way to work with the new disk as another non-RAID single disk? If relevant, I want to create a new partition in my new disk, format it with mkfs and mount it, but as I can't see it with fdisk, I don't know how to do it. Thanks!

    Read the article

  • SQL 2008 SP1 crashing almost daily

    - by matijake
    Hey, almost every day our new DB crashes. It is virtual server residing on same hardware as 5 other servers, two of them beeing identical MS SQL2008sp1 and two Oracle 11g's so I can pretty much rule out hardware issues. Server has dedicated local LUN, 4vCPU and 8GB memory with 2GB windows swap file. It runs 4 instances. Primary instance is limited to 5GB memory and paralelism set to 4 running on MS SQL 2008 SP1 @ Windows Server 2008 Enterprise R2 x64. Only that primary instance is crashing. After it crashes nothing can connect to it, it's even impossible to shut it down through service manager. What I found in logs is: ***Stack Dump being sent to C:\Program Files\Microsoft SQL Server\MSSQL10.MSSQLSERVER\MSSQL\LOG\SQLDump0081.txt SqlDumpExceptionHandler: Process 4788 generated fatal exception c0000005 EXCEPTION_ACCESS_VIOLATION. SQL Server i s terminating this process.     Whole log can be seen at: http://kabl.org/files/SQLDump0081.txt second crash log made second later at: http://kabl.org/files/SQLDump0082.txt I have analyzed mini crashdump with Microsoft tools, but no promising results. If it can help, here it is: http://kabl.org/files/SQLDump0081.mdmp Any ideas are greatly welcome, since it is becoming quite a pain in the ass to restart server almost every day :) Regrads, -Matija

    Read the article

  • Sharepoint Central Administration stuck / high CPU usage

    - by johnnyb10
    I'm using WSS 3 and I recently added a new web application to my SharePoint Server. After adding it, I wasn't able to open the Central Administration site. I also noticed that there was a w3wp.exe error (Event ID 1000) in the Event Viewer. The situation now is that the w3wp.exe process is hovering around 50% CPU usage continuously. I installed a program called IIS Peek, and it shows continuous GET requests on the Central Administration site; this happens even if I stop the Central Administration site in IIS. The IP addresses identified in the GET request is my workstation, which is what I used to attempt to access Central Administration after I created the new web application. Can someone explain what's going on and how I might fix it? It seems as if my computer tried to access Central Administration and then it hung, but the page requests that were happening at the time are somehow continuing over and over again. So my two problems are the inability to access Central Administration, and the CPU Usage of w3wp.exe, which I'm assuming are two symptoms of the same problem. I'd like to know if there's anything I can do besides restarting IIS, because we have clients accessing other sites on this server. Thanks.

    Read the article

  • MS Word 2010: Hide citation title when 2 publications by same first author from different years are in one citation block

    - by srunni
    I'm trying to hide the display of the titles for two publications by the same first author from different years that are in the same citation block. By default, the title is shown in citations when there are two publications by the same author in a given document. The easiest way to get around this is to right click on the citation, click "Edit Citation", and then suppress the title. However, the issue with this is that if there are 2 citations in 1 citation block (i.e., "(Smith, J., et al. 2010, Smith, J., et al. 2011)" rather than "(Smith, J., et al. 2010) (Smith, J., et al. 2011)"), then using that suppress option only suppresses the title for the first citation (in this case, the 2010 publication). OTOH, if I try to initially insert the publications in separate citation blocks, I can suppress the title in both citations, but I can't cut and paste one into the other's citation block. I can click "Cut" and the citation that was just cut disappears, but the "Paste" option is not available when my cursor is in the second citation block. Any ideas? Thanks!

    Read the article

  • Tracking down source of duplicate email messages in Outlook / Exchange environment

    - by Ken Pespisa
    I have a few users, who are also Blackberry users, that occasionally have duplicate emails generated from their "mailbox". I put mailbox in quotes because I'm not exactly sure where the duplicates are created. One of these users is in non-cached mode, and the other is in cached mode, and both experience the problem. In fact, the non-cached mode user was originally experiencing the problem while in cached mode, and I made the switch a few weeks ago to attempt to solve the problem. Today I discovered the issue still exists. I'm not sure if the fact that they are blackberry users could be causing the problem at all. I don't see how, but felt I should mention it anyway. Does anyone have ideas on how I might begin to troubleshoot this? I can see in the non-cached user's mailbox "Sent Items" that the message was sent only once. I confirmed the message does not state that there was a conflict and in fact that makes sense because they are in non-cached mode. On the server, we have a mail journaling feature turned on for our third-party mail archiving system, and I can see that that system sees two sent messages. And likewise, the recipient does in fact have two messages in their inbox with consecutive message IDs ([email protected]) and ([email protected]). It would seem to me that the duplicates are generated on the client, but is there a way to tell for sure?

    Read the article

  • Why does this loopback device creation malfunction?

    - by user50118
    The stackoverflow people thought this was more appropriate here, I put it there as it is part of a program but I can see their POV, so here it is: At the bottom of the code you can see it failing. In fact, I'll put it here at the start too because it is the problem I need to solve: [350591.924819] EXT4-fs (loop0): bad geometry: block count 9750806 exceeds size of device (9750168 blocks) I don't understand why the device is supposedly too small. I made this partition two days ago with normal fdisk, it was created and formatted with ext4 supplying no options other than the partition (/dev/sdb2) to format. The only explaination I can think of is that ext4 has the size of the partition wrong somehow but that seems very unlikely. What is wrong with my math? The offset is correct, you can see that with the file command, and the size should be correct too because End - Start comes to the same number of sectors minus 1, just like it should (A disk starting on sector 1 and ending on sector 2 would be 2 - 1 = 1 and have two sectors). # sfdisk -luS /dev/sdb Disk /dev/sdb: 9729 cylinders, 255 heads, 63 sectors/track Units = sectors of 512 bytes, counting from 0 Device Boot Start End #sectors Id System /dev/sdb2 78295040 156296384 78001345 83 Linux # losetup -r -f --show -o $((78295040 * 512)) --sizelimit $((78001345 * 512)) /dev/sdb /dev/loop0 # file -s /dev/loop0 /dev/loop0: Linux rev 1.0 ext4 filesystem data (needs journal recovery) (extents) (large files) (huge files) # mount -o ro -t ext4 /dev/loop0 /mnt mount: wrong fs type, bad option, bad superblock on /dev/loop0, missing codepage or helper program, or other error In some cases useful info is found in syslog - try dmesg | tail or so # dmesg | tail -n 1 [350591.924819] EXT4-fs (loop0): bad geometry: block count 9750806 exceeds size of device (9750168 blocks)

    Read the article

  • NAT confusion regarding cisco ASA5510

    - by LonelyLonelyNetworkN00b
    I'm setting up my first cisco firewalls. A little information first:I have two asa5510 setup in a working active/standby pair. From my ISP i have two public subnets. A /29 and a /26. On my DMZ interface i have the /26 configured. On my WAN Interface i have configured the /29 IPs. My isp routes the /26 via the /29 primary IP. I'm running ASA 8.2. I've turned NAT-Control off, because i don't want to use nat for for other than some internal interfaces. In essence i don't want to use NAT unless i specify it. I have a internal interface with the network of 192.168.100.0/24. I've tried setting up nat limke this: nat (inside) 1 192.168.100.0 255.255.255.0 global (WAN) 1 interface I was under the impression that this would let connections that was going from 192.168.100.0/24 and out the WAN interface to be Port-Address-translated. I'm not getting this to work for some reason. Inside interface has security level of 100, and wan has security level of 0.

    Read the article

  • Triple monitor setting in Linux with USB-HDMI adapter

    - by Oscar Carballal
    I'm trying to set up a triple monitor desktop at my office using Fedora 17, but it seems impossible, let me explain the setting: Laptop ASUS K53SD with 2 graphic cards, Intel and nVidia (Screen controled by Intel card) 24" Full HD monitor connected to the HDMI output (controlled by Intel card) 23" Full HD monitor connected to an USB-HDMI adapter (via framebuffer in /dev/fb2, apparently) VGA output (not used) controlled by nVidia card First of all, the USB-HDMI adapter works perfectly, it gives me a green screen (which means the communication is OK) and I can make it work if I set up a single monitor setting via framebuffer in Xorg. Here I leave the page where I got the instructions: http://plugable.com/2011/12/23/usb-graphics-and-linux Now I'm trying to set up the the two main monitors (laptop and 24") with the intel driver and the 23" with the framebuffer, but the most succesful configuration I get is the two main monitors working and the third disconnected. Do you have any idea what can I do to make this work? Here I leave my xRandr output and my Xorg conf: -> xrandr Screen 0: minimum 320 x 200, current 3286 x 1080, maximum 8192 x 8192 LVDS1 connected 1366x768+0+0 (normal left inverted right x axis y axis) 344mm x 193mm 1366x768 60.0*+ 1024x768 60.0 800x600 60.3 56.2 640x480 59.9 VGA2 disconnected (normal left inverted right x axis y axis) HDMI1 connected 1920x1080+1366+0 (normal left inverted right x axis y axis) 531mm x 299mm 1920x1080 60.0*+ 50.0 25.0 30.0 1680x1050 59.9 1680x945 60.0 1400x1050 74.9 59.9 1600x900 60.0 1280x1024 75.0 60.0 1440x900 75.0 59.9 1280x960 60.0 1366x768 60.0 1360x768 60.0 1280x800 74.9 59.9 1152x864 75.0 1280x768 74.9 60.0 1280x720 50.0 60.0 1440x576 25.0 1024x768 75.1 70.1 60.0 1440x480 30.0 1024x576 60.0 832x624 74.6 800x600 72.2 75.0 60.3 56.2 720x576 50.0 848x480 60.0 720x480 59.9 640x480 72.8 75.0 66.7 60.0 59.9 720x400 70.1 DP1 disconnected (normal left inverted right x axis y axis) 1920x1080_60.00 60.0 The Xorg file: # Xorg configuration file for using a tri-head display Section "ServerLayout" Identifier "Layout0" Screen 0 "HDMI" 0 0 Screen 1 "USB" RightOf "HDMI" Option "Xinerama" "on" EndSection ########### MONITORS ################ Section "Monitor" Identifier "USB1" VendorName "Unknown" ModelName "Acer 24as" Option "DPMS" EndSection Section "Monitor" Identifier "HDMI1" VendorName "Unknown" ModelName "Acer 23SH" Option "DPMS" EndSection ########### DEVICES ################## Section "Device" Identifier "Device 0" Driver "intel" BoardName "GeForce" BusID "PCI:0:02:0" Screen 0 EndSection Section "Device" Identifier "USB Device 0" driver "fbdev" Option "fbdev" "/dev/fb2" Option "ShadowFB" "off" EndSection ############## SCREENS ###################### Section "Screen" Identifier "HDMI" Device "Device 0" Monitor "HDMI1" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "USB" Device "USB Device 0" Monitor "USB1" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection

    Read the article

  • How can I make XAnalogTV fill my screen?

    - by Breakthrough
    I recently installed xscreensaver, as well as the additional/extra screensavers. Many of the OpenGL ones function correctly, going fullscreen as expected. However, for some reason, the XAnalogTV screensaver leaves two "blank" spots on the edges of my screen. If I manually launch XAnalogTV, it displays a window, which it fills correctly. When I maximize the window, the same effect occurs: the window maximizes, but the two edges of the screen are literally "transparent". This effect also occurs when the screensaver is set to fullscreen. For these reasons, I believe the problem may be related to the aspect ratio of the screen. The edges of the screen are literally "ignored", with nothing being drawn there. Specifically, note the transition between the maximized and full-screen screenshots (with the un-drawn whitespace shrinking as the vertical height has been increased). For reference, I am running Xubuntu 12.04 on a Dell Vostro 1520 (Intel P8600, Nvidia 9300M) with a 1440 x 900 display (16:10). I have also set the GetViewPortIsFullOfLies preference to true. Is there any way to force XAnalogTV to fill my entire screen? Relevant screenshots (windowed, maximized, and full-screen, respectively):

    Read the article

< Previous Page | 377 378 379 380 381 382 383 384 385 386 387 388  | Next Page >