Search Results

Search found 28880 results on 1156 pages for 'check disk'.

Page 388/1156 | < Previous Page | 384 385 386 387 388 389 390 391 392 393 394 395  | Next Page >

  • How to tune system settings for mongoDB on Linux?

    - by jsh
    Trying to squeeze a lot out of one question here -- please bear with me. Although the MongoDB man pages make several useful recommendations about system settings like ulimit (http://docs.mongodb.org/manual/reference/ulimit/), and other production factors (http://docs.mongodb.org/manual/administration/production-notes/) they seem mysteriously silent on things like virtual memory and swap settings. The closest we get to a hint is that "...the operating system’s virtual memory subsystem manages MongoDB’s memory..." (http://docs.mongodb.org/manual/faq/fundamentals/#does-mongodb-require-a-lot-of-ram). Running the same job - high writes and high reads on about 10,000,000 records in a single collection -- on my 4-processor, 4GB RAM macbook and an 8-core ubuntu box with 64GB RAM I saw dramatically WORSE read performance on the linux box with factory settings, and could hear the disk constantly spinning, indicating high I/O and presumably swapping. Yes, other things were happening on the box, but there was plenty of free RAM, disk space, etc.; furthermore, I did not see evidence that Mongo was expanding to take advantage of all that free RAM as it is touted to do. Linux box default settings were as follows: vm.swappiness =60 vm.dirty_background_ratio = 10 vm.dirty_ratio = 20 vm.dirty_expire_centisecs =3000 vm.dirty_writeback_centisecs=500 I hazarded some guesses looking at docs and blogs for other types of databases (Oracle, MYSQL, etc.), experimented, and adjusted as below. vm.swappiness=10 vm.dirty_background_ratio=5 vm.dirty_ratio=5 vm.dirty_writeback_centisecs=250 vm.dirty_expire_centisecs=500 I saw some immediate apparent improvements in read time. However, when I ran my test jobs again, read performance continued to be painfully sluggish during heavy writes. Then, I REBUILT the collection from an available data source - and suddenly I can read at 1ms or less per record WHILE doing the write job! So the question is really two-fold: 1) What are appropriate VM settings for MongoDB on Linux? 2) (bonus) Does Mongo do some checking or optimization with the OS while data is being built? In other words, if I have built a large data set with suboptimal VM or I/O settings, does Mongo make assumptions during the memory-mapping process that will fail to take advantage of optimizations down the road? Obviously I don't fully grok memory mapping under the hood (I was hoping I wouldn't have to). Any help appreciated...thanks! -j

    Read the article

  • Does putting the XFS log on an SSD significantly improve performance?

    - by Paul Wagland
    I have a five disk array running XFS in RAID5, and I would like to improve it's performance. I have seen some hints that putting the log onto a separate device can help, does putting the log onto an SSD help dramtically? In theory, it should, but I have not been able to find any case studies where someone has actually done this, and buying an SSD and then having it not work well would be inconvenient at best…

    Read the article

  • Prevent Concurrent File Changes: Windows Server 2003

    - by ThinkBohemian
    I have a program installed that writes configurations to disk installed on Windows Server 2003. When two administrators log into the machine at the same time, the last admin to save will persist their configurations, while the first admin's saves will be lost. Is there any way I can restrict access to a only this program so that only one person can edit it at a time? If not, is it possible to restrict user access to only one program?

    Read the article

  • Router vs switch in a LAN [closed]

    - by servernewbie
    If I have a LAN and and connect it with a switch, I understand it uses a CAM table to route packets in layer 2 (by saving mac to port relations). So far all good. However, when using a router for a LAN (ONLY for a LAN, not to connect it to "the outside" WAN/internet/etc) I get a bit confused as to how it internally processes packets. I would first split this into two router scenarios: Router with buit-in switch In this scenario, I would expect that it will act exactly as a switch with a CAM table internally. This would probably benefit a bit in speed (guessing here?) compared to the next option. Router without built-in switch Here is where I get confused. If hostA wants to send a packet to hostB, it will ARP to find hostB's MAC address and send it there. Now, if we had a switch (above scenario) this would be easy. But how does it work now in a router WITHOUT a switch? If I would guess, hostA would send an Ethernet frame with hostB's MAC address to the line. The router would fetch the packet (even though the router has another MAC address, it would still fetch this packet even if it only contains hostB's MAC address). It would strip the Ethernet frame header and check the IP, and then check its own internal ARP table again for the MAC address. Now, this would seem like a waste of resources compared to a router with a built-in switch. But maybe it does not work like that at all. Does it also contain a CAM table? If that would be true, what would then the difference between these two routers really be?

    Read the article

  • ZFS recordsize for VirtualBox and other virtual disks

    - by JOTN
    Has anyone run across any good benchmarks or other research on tuning the ZFS recordsize when putting virtual disk files on it for a guest OS? I'm using VirtualBox at the moment. I have notice significant performance improvement when working with a DBMS by setting the ZFS recordsize to the same as the DB blocksize, so I'm guessing matching the blocksize of the guest filesystem would also be a good idea.

    Read the article

  • Is there a system monitoring tool that lets me write complex queries against the data?

    - by benhsu
    I am looking for a system stat collection tool that will let me write queries against the data collected. I am planning to answer questions like: what is the average load, over the last 30 days, on this machine between 9AM and 5PM, as opposed to at night what was the average disk io on these 10 machines yesterday what was the average daytime memory usage on these 10 machines last week, as opposed to 2 weeks ago Has anyone done this with, say, collectd or graphite?

    Read the article

  • Recognition of USB drive

    - by lamcro
    I have a Motorola phone, with a MicroSD slot, which my Ubuntu machine does not recognize as a USB drive. It does know there is something there since It automatically charges my phone whenever I connect it. using the command lsusb shows it as "Motorola PCS" Is there a way to tell Ubuntu/Linux that the connected hardware is a disk drive?

    Read the article

  • "What happens?" server performance monitor

    - by AlexAtNet
    Hello! After reviewing some thread about server monitoring software I end up with a simple question: Which of the server monitoring tools should I use for automatic detection of "abnormal" situations with recommendations on how to fix them? I look for software that checks the system performance after installation and calculate some average load values (memory, CPU, etc). And when something happens (CPU load is increased to 20%) then it tries to detect a reason for this. If it is apache, it should check for access logs. If mysql, it should check mysql logs and tell me what happens. It this is because some user decodes a lot of images, I'd like to know which command is executed, when and user name. The same for disk usage, memory, number of processes, threads and so on. Ideally, this software should periodically checks the system and report problems: errors in PHP error log, outdated packages, security vulnerabilities. In other word I'm looking a software that will keep my simple Debian/Apache/PHP/MySQL server without forcing me to monitor the charts every day. I hope that such program exists. Thanks, Alex

    Read the article

  • How can I change the binding order of network adapters in Windows 7?

    - by Chris Farmer
    The end goal here is that I am trying to install an Oracle 10g server on my Windows 7 x64 dev box. I use DHCP, and the Oracle installer is throwing up this warning: Checking Network Configuration requirements ... Check complete. The overall result of this check is: Failed <<<< Problem: The install has detected that the primary IP address of the system is DHCP-assigned. Recommendation: Oracle supports installations on systems with DHCP-assigned IP addresses; However, before you can do this, you must configure the Microsoft LoopBack Adapter to be the primary network adapter on the system. See the Installation Guide for more details on installing the software on systems configured with DHCP. I have installed the loopback adapter, but I am not sure how to make it the primary network adapter. I see this Microsoft KB article on the subject but it's Windows XP-oriented, and I can't seem to find a comparable one for Windows 7. Some of the options it talks about don't seem to be present in the views of the adapters that I see. So, how can I make the loopback adapter become the primary adapter?

    Read the article

  • Why does HP Update at remote system trigger RDP printing at local system?

    - by lcbrevard
    This is obscure. When connected with RDP to another system that has HP Update installed on it, either directly running the HP Update or having the notification pop up to ask if you want to run HP Update causes the local system to try to print something to peculiarly-chosen-local-printer. Case 1: Desktop Win 7 Ult system RDP connected to HP Laptop Win 7 Ult system. When HP Update runs on the laptop a dialog for XPS Writer Save As... appears on Desktop system. Even if you put in a name, nothing gets generated and the dialog repeats. And repeats. Until you (a) close the RDP connection and (b) clean out the queued entries. If the HP Update pops up the request to run the update and you are not at the desk when this happens, there can be dozens of queued requests for this bogus printing. NOTE: the XPS Writer is not selected as a default printer on either system. Case 2: (Different) HP Laptop Win 7 Ult system RDP connected to XP Pro "brand X" desktop system but with HP printer drivers installed. If the request to run HP Update notification pops on the XP system, dozens of attempts to print, in this case to a Versa Check Printer driver, are queued. Dismissing the HP request, closing RDP, and cleaning out the queue are required to stop this. NOTE: the Versa Check Writer is not selected as a default printer on either system. THE QUESTION: What the heck is going on here? Some kind of scripting or COM activity that is misdirected?

    Read the article

  • iTunes can't see iPhone after reinstalling Leopard

    - by Joseph SG
    My Mac hard disk died, so I replaced it and installed OS X Leopard 10.5.8. Problem now, iTunes doesn't see my iPhone 3GS at all. iPhoto works just fine, but iTunes is blind. I have too much info on my iPhone, I don't wish to restore/reset it and wish to get everything from my iPhone sync'd into iTunes afresh. How can I do that?

    Read the article

  • Fix single entry from mbr

    - by Sander
    I use EasyBCD to manage my tripleboot of (1) Windows Server 2008 R2, (2) Windows 7 Professional and (3) Ubuntu Linux. While trying to change the order of my boot menu I ended up losing the Windows Server entry. Luckily I had a boot menu backup (.bcd file) that allowed me to restore my boot menu using EasyBCD. However, when I now select the Windows Server option in my boot menu the Windows Server Recovery Environment starts up. So I have to select language/keyboard layout/etc. and then I have 3 options as shown in the image below. . My goal is to fix the one corrupted Windows Server entry from my boot menu without messing up or losing the two other ones. I'm guessing the Recovery Console (Command Prompt) is the next step and that I will be needing bootrec.exe. But when consulting this page: Use the Bootrec.exe tool in the Windows Recovery Environment to troubleshoot and repair startup issues in Windows (about half way down there's a link that shows the bootrec.exe options) I'm getting uncertain. The page lists 4 options for bootrec.exe : /FixMbr /FixBoot /ScanOs /RebuildBcd What option do I need to fix just the server entry of my boot menu? Thanks in advance, Sander P.S. All three OS's are on the same physical disk (3 different partitions). Disk layout: System reserved (primary partition, 100 MB) Windows 7 (primary parition, 150 GB) Windows Server 2008 (primary partition, 150 GB) Extended partition (linux partitions (/,/swap,/home), 150GB + data partition, 150 GB) P.P.S. This is what my boot menu looks like using EasyBCD (Detailed/Debug mode) on my Windows 7 installation. Windows Boot Manager -------------------- identifier {9dea862c-5cdd-4e70-acc1-f32b344d4795} device partition=\Device\HarddiskVolume1 description Windows Boot Manager locale en-US inherit {7ea2e1ac-2e61-4728-aaa3-896d9d0a9f0e} default {93f90e43-cae8-11df-b05a-c9177e705936} resumeobject {93f90e3e-cae8-11df-b05a-c9177e705936} displayorder {93f90e43-cae8-11df-b05a-c9177e705936} {93f90e3f-cae8-11df-b05a-c9177e705936} {93f90e46-cae8-11df-b05a-c9177e705936} toolsdisplayorder {b2721d73-1db4-4c62-bf78-c548a880142d} timeout 10 displaybootmenu Yes Windows Boot Loader ------------------- identifier {93f90e43-cae8-11df-b05a-c9177e705936} device partition=\Device\HarddiskVolume3 path \Windows\system32\winload.exe description Windows Server 2008 R2 - Standard locale en-US inherit {6efb52bf-1766-41db-a6b3-0ee5eff72bd7} recoverysequence {93f90e44-cae8-11df-b05a-c9177e705936} recoveryenabled Yes osdevice partition=\Device\HarddiskVolume3 systemroot \Windows resumeobject {93f90e42-cae8-11df-b05a-c9177e705936} nx OptOut Windows Boot Loader ------------------- identifier {93f90e3f-cae8-11df-b05a-c9177e705936} device partition=C: path \Windows\system32\winload.exe description Windows 7 - Professional locale nl-NL inherit {6efb52bf-1766-41db-a6b3-0ee5eff72bd7} recoverysequence {93f90e40-cae8-11df-b05a-c9177e705936} recoveryenabled Yes osdevice partition=C: systemroot \Windows resumeobject {93f90e3e-cae8-11df-b05a-c9177e705936} nx OptIn Real-mode Boot Sector --------------------- identifier {93f90e46-cae8-11df-b05a-c9177e705936} device partition=C: path \NST\AutoNeoGrub0.mbr description Ubuntu 10.04 - Lucid Lynx

    Read the article

  • Zabbix not getting data for one filesystem

    - by Dennis Williamson
    I have Zabbix monitoring disk space for several volumes on several servers. It works fine on all of them except for one of the volumes on one of the servers which always reports as 0. However, when I run ./zabbix_get -s localhost -p 10050 -k 'vfs.fs.size[/home, free]' locally on the machine in question, it gives me the correct, non-zero size which matches the output of df. How can I go about troubleshooting and correcting this problem?

    Read the article

  • Windows install missing NTLDR

    - by Jack
    Hi all. I'm having trouble install WinXP Pro on my pc because NTLDR is missing or can't find during installation process. I highly doubt it's my DVD drive because this machine work fine before the install process. The DVD rom work. Is there a work around for this problem? edit: this is the problem that i'm having. I'm trying to reformat the hard disk with killdisk.

    Read the article

  • Does changing the default HDFS replication factor from 3 affect mapper performance?

    - by liamf
    Have a HDFS/Hadoop cluster setup and am looking into tuning. I wonder if changing the default HDFS replication factor (default:3) to something bigger will improve mapper performance, at the obvious expense of increasing disk storage used? My reasoning being that if the data is already replicated to more nodes, mapper jobs can be run on more nodes in parallel without any data streaming/copying? Anyone got any opinions?

    Read the article

  • Recover strategy single bad sector in moricon

    - by Damon
    This week, my harddisk made me an early christmas present in the form of a single defect sector. To make up for the puny size of the present, it chose a sector inside moricons.dll for that. This means that now the system takes about 5 minutes to boot before Windows gives up and moves on, and there's 2 dozen scary "critical failure" entries in the system log after every boot, which is annoying. OK, admittedly, I shouldn't complain, it could be worse, the bad sector could be in ntldr... SMART info more or less indicates (for what SMART can indicate anyway) that the drive is mostly OK. Soft Read Error Rate has a score of 96, and Current Pending Sector Count has a raw value of 8, which translates to a score of 100. Acronis DriveMonitor makes this an issue (lowering the overall rating to 75%), HDD Health calls it "excellent", giving an overall rating of 95% (which is what this harddisk from day one). No single score is below 95 (power on hours and spin up count), and most are 100 anyway. Well, whatever, I've seen drives with perfect SMART values fail from one second to the other, and drives with moderate values work for years. So, I'm inclined not to put too much weight into that overall. TL;DR Now... to the problem: I don't feel like trashing the disk just yet (that's planned with a new OS install upgrading to Win7 early next year, independently of this issue), but in the mean time, I would still like to have a smoothly running system again. Therefore, I feel tempted to tamper with it, but before I render my system entirely unusable (since I've never done this before), I'd like to verify that my planned procedere is likely to suceed in having a working system again: Copy moricons.dl_ from the Windows install disk, rename it to moricons.zip, and unzip it. This gives an intact 5.1.2600.2180 version (the broken one is 5.1.2600.5512 - but I guess this makes not much of a difference, since it's an icon-only DLL, and an outdated copy should work better than one that can't be read) Run chkdsk /r /f` which will "repair" the file (i.e. delete the file without asking, tell the drive to remap the sector, and toss some unreadable junk into a file with a hexadecimal number) Hopefully Windows still boots after this (is that a reasonable expectation, or do I need to have something like BartPE ready? -- but then again, what's that good for in case chkdsk has nuked the entire file system...) Delete the junk file generated by chkdsk, copy the new DLL to %windir%\system32 Reboot. Pray. Maybe I just shouldn't touch anything, since it still kind of works... if annoying, but it works. Unsure... But, is there anything fundamentally wrong with the planned approach? Is this a sensible approach at all?

    Read the article

  • Blue Screen error BAD_POOL_CALLER 0x000000C2

    - by Adam
    My computer was working fine for months but now when it starts up the Windows XP screen comes up to show the computer is starting up but then a blue screen appears with the error below: BAD_POOL_CALLER STOP: 0x000000C2 (0x00000043, 0xDB3C6000, 0x00000000, 0x00000000) I have tried booting off the Windows XP CD and trying to do a re-installation but when the setup try's to query the disk the setup crashes and exists. I've run diags and that says everything is fine. Any ideas?

    Read the article

  • grub refuses to install to raid array

    - by ronno
    I have a software raid 0 setup with dual booting Windows 7 and Ubuntu 12.04. The GRUB bootloader that is already on the hard drive seems to work fine. However, since the latest package update for grub, it refuses to install the new version to the hard disk. grub-install throws the following error: /usr/sbin/grub-probe: error: cannot find a GRUB drive for /dev/mapper/< raid name_RAID0p9. Check your device.map. Auto-detection of a filesystem of /dev/mapper/< raid name_RAID0p9 failed. Try with --recheck. If the problem persists please report this together with the output of "/usr/sbin/grub-probe --device-map="/boot/grub/device.map" --target=fs -v /boot/grub" to < [email protected] update-grub pops the same "/usr/sbin/grub-probe: error: cannot find a GRUB drive for /dev/mapper/< raid name_RAID0p9. Check your device.map." every alternate line. I don't understand what exactly is going on. I'm afraid to reinstall the grub package because it might mess up the boot, which currently works fine. Is it safe to just ignore this?

    Read the article

  • iMac MXM Update Failing

    - by dmcollie
    Hi all iMac 24" Late 2006 Mac OS X (10.6.3) I'm trying to install Bootcamp. I've partitioned my HD but when I reboot with the Windows installation disk I get a black (blank) screen. The advice from the Apple Support website is to install the MXM Update but when I run that as per the instructions I get this error: An unexpected error occurred (11.1). Your firmware cannot be updated. Any ideas on how to proceed? Thanks.

    Read the article