Search Results

Search found 42321 results on 1693 pages for 'sql reporting services 05'.

Page 431/1693 | < Previous Page | 427 428 429 430 431 432 433 434 435 436 437 438  | Next Page >

  • Fun with upgrading and BCP

    - by DavidWimbush
    I just had trouble with using BCP out via xp_cmdshell. Probably serves me right but that's a different issue. I got a strange error message 'Unable to resolve column level collations' which turned out to be a bit misleading. I wasted some time comparing the collations of the the server, the database and all the columns in the query. I got so desperate that I even read the Books Online article. Still no joy but then I tried the interweb. It turns out that calling bcp without qualifying it with a path causes Windows to search the folders listed in the Path environment variable - in that order - and execute the first version of BCP it can find. But when you do an in-place version upgrade, the new paths are added on the end of the Path variable so you don't get the latest version of BCP by default. To check which version you're getting execute bcp -v at the command line. The version number will correspond to SQL Server version numbering (eg. 10.50.n = 2008 R2). To examine and/or edit the Path variable, right-click on My Computer, select Properties, go to the Advanced tab and click on the Environment Variables button. If you change the variable you'll have to restart the SQL Server service before it takes effect.

    Read the article

  • SQL Azure Service Issues &ndash; 10.27.2012 (Restored Now)

    - by ToStringTheory
    Please note that if you have a Windows Azure website, or use SQL Azure, your site may be experiencing downtime currently.  Notice I just called in regarding one of my public facing internet sites, because the site was failing to load anything but its error page, I couldn’t connect to the database to inspect application error logs, and the Windows Azure Management portal won’t load the SQL Azure extension. After speaking to the representative, he also mentioned that they were also having some problems updating the Service Dashboard which shows service up/down time, and for now, they are posting messages at http://account.windowsazure.com.  Please note that this issue may only be effecting certain regions.  Last, I may have misheard the representative, but he said that the outage was being categorized as a level 8, and if I heard correctly, I think he said that level 8 was the worst level.  I can’t say for sure on this though, because the phone connection to their support number was bad – large amounts of white noise. Good Luck! Update It appears that this outage may also be effecting the following services: SQL Database, Service Bus, Datamarket, Windows Azure Marketplace, Shared Caching, Access Control 2.0, and SQL Reporting. The note on the account page says for the South Central US region, however, I believe the representative I spoke to also mentioned North Central. As I said before though, the connection was bad. Update 2 My site regained connectivity about an hour ago, and it appears that the service dashboard is back in operation with correct status and history. It does appear that I misheard on the phone regarding multiple regions, so chances are this only effected a percentage of the platform. All in all, if this WAS their worst level of a problem, they really got it fixed and back up pretty fast. All in all, I understand that it is inherent for a complex system such as Azure to have ups and downs, but at the end of the day, I am still happy to support Azure to its fullest!

    Read the article

  • WIF, ADFS 2 and WCF&ndash;Part 6: Chaining multiple Token Services

    - by Your DisplayName here!
    See the previous posts first. So far we looked at the (simpler) scenario where a client acquires a token from an identity provider and uses that for authentication against a relying party WCF service. Another common scenario is, that the client first requests a token from an identity provider, and then uses this token to request a new token from a Resource STS or a partner’s federation gateway. This sounds complicated, but is actually very easy to achieve using WIF’s WS-Trust client support. The sequence is like this: Request a token from an identity provider. You use some “bootstrap” credential for that like Windows integrated, UserName or a client certificate. The realm used for this request is the identifier of the Resource STS/federation gateway. Use the resulting token to request a new token from the Resource STS/federation gateway. The realm for this request would be the ultimate service you want to talk to. Use this resulting token to authenticate against the ultimate service. Step 1 is very much the same as the code I have shown in the last post. In the following snippet, I use a client certificate to get a token from my STS: private static SecurityToken GetIdPToken() {     var factory = new WSTrustChannelFactory(         new CertificateWSTrustBinding(SecurityMode.TransportWithMessageCredential,         idpEndpoint);     factory.TrustVersion = TrustVersion.WSTrust13;       factory.Credentials.ClientCertificate.SetCertificate(         StoreLocation.CurrentUser,         StoreName.My,         X509FindType.FindBySubjectDistinguishedName,         "CN=Client");       var rst = new RequestSecurityToken     {         RequestType = RequestTypes.Issue,         AppliesTo = new EndpointAddress(rstsRealm),         KeyType = KeyTypes.Symmetric     };       var channel = factory.CreateChannel();     return channel.Issue(rst); } To use a token to request another token is slightly different. First the IssuedTokenWSTrustBinding is used and second the channel factory extension methods are used to send the identity provider token to the Resource STS: private static SecurityToken GetRSTSToken(SecurityToken idpToken) {     var binding = new IssuedTokenWSTrustBinding();     binding.SecurityMode = SecurityMode.TransportWithMessageCredential;       var factory = new WSTrustChannelFactory(         binding,         rstsEndpoint);     factory.TrustVersion = TrustVersion.WSTrust13;     factory.Credentials.SupportInteractive = false;       var rst = new RequestSecurityToken     {         RequestType = RequestTypes.Issue,         AppliesTo = new EndpointAddress(svcRealm),         KeyType = KeyTypes.Symmetric     };       factory.ConfigureChannelFactory();     var channel = factory.CreateChannelWithIssuedToken(idpToken);     return channel.Issue(rst); } For this particular case I chose an ADFS endpoint for issued token authentication (see part 1 for more background). Calling the service now works exactly like I described in my last post. You may now wonder if the same thing can be also achieved using configuration only – absolutely. But there are some gotchas. First of all the configuration files becomes quite complex. As we discussed in part 4, the bindings must be nested for WCF to unwind the token call-stack. But in this case svcutil cannot resolve the first hop since it cannot use metadata to inspect the identity provider. This binding must be supplied manually. The other issue is around the value for the realm/appliesTo when requesting a token for the R-STS. Using the manual approach you have full control over that parameter and you can simply use the R-STS issuer URI. Using the configuration approach, the exact address of the R-STS endpoint will be used. This means that you may have to register multiple R-STS endpoints in the identity provider. Another issue you will run into is, that ADFS does only accepts its configured issuer URI as a known realm by default. You’d have to manually add more audience URIs for the specific endpoints using the ADFS Powershell commandlets. I prefer the “manual” approach. That’s it. Hope this is useful information.

    Read the article

  • Cluster Nodes as RAID Drives

    - by BuckWoody
    I'm unable to sleep tonight so I thought I would push this post out VERY early. When you don't sleep your mind takes interesting turns, which can be a good thing. I was watching a briefing today by a couple of friends as they were talking about various ways to arrange a Windows Server Cluster for SQL Server. I often see an "active" node of a cluster with a "passive" node backing it up. That means one node is working and accepting transactions, and the other is not doing any work but simply "standing by" waiting for the first to fail over. The configuration in the demonstration I saw was a bit different. In this example, there were three nodes that were actively working, and a fourth standing by for all three. I've put configurations like this one into place before, but as I was looking at their architecture diagram, it looked familar - it looked like a RAID drive setup! And that's not a bad way to think about your cluster arrangements. The same concerns you might think about for a particular RAID configuration provides a good way to think about protecting your systems in general. So even if you're not staying awake all night thinking about SQL Server clusters, take this post as an opportunity for "lateral thinking" - a way of combining in your mind the concepts from one piece of knowledge to another. You might find a new way of making your technical environment a little better. Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • Vagrant reporting VirtualBox guest additions out of date

    - by DTest
    Fairly new to Vagrant, so bear with me if I don't understand the process. I downloaded a CentOS box off http://www.vagrantbox.es/ Started it up running VirtualBox 4.2.4 and got this message: [default] The guest additions on this VM do not match the install version of VirtualBox! This may cause things such as forwarded ports, shared folders, and more to not work properly. If any of those things fail on this machine, please update the guest additions and repackage the box. Guest Additions Version: 4.0.8 VirtualBox Version: 4.2.4 So I used the vbguest plugin to update the guest additions, then repackaged the box as suggested. Having replaced the old box and loading it up I get the same message about guest additions being outdated, but vbguest reports that they are up to date (the automatic vbguest update is disabled in my Vagrantfile): Vagrant::Config.run do |config| config.vm.box = "centos56_64" config.vbguest.auto_update = false config.vbguest.no_remote = true end And the commands: dtest$ vagrant up [default] Importing base box 'centos56_64'... [default] The guest additions on this VM do not match the install version of VirtualBox! This may cause things such as forwarded ports, shared folders, and more to not work properly. If any of those things fail on this machine, please update the guest additions and repackage the box. Guest Additions Version: 4.0.8 VirtualBox Version: 4.2.4 [default] Matching MAC address for NAT networking... [default] Clearing any previously set forwarded ports... [default] Forwarding ports... [default] -- 22 => 2222 (adapter 1) [default] Creating shared folders metadata... [default] Clearing any previously set network interfaces... [default] Booting VM... [default] Waiting for VM to boot. This can take a few minutes. [default] VM booted and ready for use! [default] Mounting shared folders... [default] -- v-root: /vagrant dtest$ vagrant vbguest --no-install [default] Detected Virtualbox Guest Additions 4.2.4 --- OK. [default] Virtualbox Guest Additions on host: 4.2.4 - guest's version is 4.2.4 Since they appear to be updated after an install, I could ignore the message. But is it possible to get rid of it?

    Read the article

  • Generic Repository with SQLite and SQL Compact Databases

    - by Andrew Petersen
    I am creating a project that has a mobile app (Xamarin.Android) using a SQLite database and a WPF application (Code First Entity Framework 5) using a SQL Compact database. This project will even eventually have a SQL Server database as well. Because of this I am trying to create a generic repository, so that I can pass in the correct context depending on which application is making the request. The issue I ran into is my DataContext for the SQL Compact database inherits from DbContext and the SQLite database inherits from SQLiteConnection. What is the best way to make this generic, so that it doesn't matter what kind of database is on the back end? This is what I have tried so far on the SQL Compact side: public interface IRepository<TEntity> { TEntity Add(TEntity entity); } public class Repository<TEntity, TContext> : IRepository<TEntity>, IDisposable where TEntity : class where TContext : DbContext { private readonly TContext _context; public Repository(DbContext dbContext) { _context = dbContext as TContext; } public virtual TEntity Add(TEntity entity) { return _context.Set<TEntity>().Add(entity); } } And on the SQLite side: public class ElverDatabase : SQLiteConnection { static readonly object Locker = new object(); public ElverDatabase(string path) : base(path) { CreateTable<Ticket>(); } public int Add<T>(T item) where T : IBusinessEntity { lock (Locker) { return Insert(item); } } }

    Read the article

  • Designing a Database Application with OOP

    - by Tim C
    I often develop SQL database applications using Linq, and my methodology is to build model classes to represent each table, and each table that needs inserting or updating gets a Save() method (which either does an InsertOnSubmit() or SubmitChanges(), depending on the state of the object). Often, when I need to represent a collection of records, I'll create a class that inherits from a List-like object of the atomic class. ex. public class CustomerCollection : CoreCollection<Customer> { } Recently, I was working on an application where end-users were experiencing slowness, where each of the objects needed to be saved to the database if they met a certain criteria. My Save() method was slow, presumably because I was making all kinds of round-trips to the server, and calling DataContext.SubmitChanges() after each atomic save. So, the code might have looked something like this foreach(Customer c in customerCollection) { if(c.ShouldSave()) { c.Save(); } } I worked through multiple strategies to optimize, but ultimately settled on passing a big string of data to a SQL stored procedure, where the string has all the data that represents the records I was working with - it might look something like this: CustomerID:34567;CurrentAddress:23 3rd St;CustomerID:23456;CurrentAddress:123 4th St So, SQL server parses the string, performs the logic to determine appropriateness of save, and then Inserts, Updates, or Ignores. With C#/Linq doing this work, it saved 5-10 records / s. When SQL does it, I get 100 records / s, so there is no denying the Stored Proc is more efficient; however, I hate the solution because it doesn't seem nearly as clean or safe. My real concern is that I don't have any better solutions that hold a candle to the performance of the stored proc solution. Am I doing something obviously wrong in how I'm thinking about designing database applications? Are there better ways of designing database applications?

    Read the article

  • SQL Server Interview Questions

    - by Rodney Vinyard
    User-Defined Functions Scalar User-Defined Function A Scalar user-defined function returns one of the scalar data types. Text, ntext, image and timestamp data types are not supported. These are the type of user-defined functions that most developers are used to in other programming languages. Table-Value User-Defined Function An Inline Table-Value user-defined function returns a table data type and is an exceptional alternative to a view as the user-defined function can pass parameters into a T-SQL select command and in essence provide us with a parameterized, non-updateable view of the underlying tables. Multi-statement Table-Value User-Defined Function A Multi-Statement Table-Value user-defined function returns a table and is also an exceptional alternative to a view as the function can support multiple T-SQL statements to build the final result where the view is limited to a single SELECT statement. Also, the ability to pass parameters into a T-SQL select command or a group of them gives us the capability to in essence create a parameterized, non-updateable view of the data in the underlying tables. Within the create function command you must define the table structure that is being returned. After creating this type of user-defined function, I can use it in the FROM clause of a T-SQL command unlike the behavior found when using a stored procedure which can also return record sets.

    Read the article

  • SQL Rally Pre-Con: Data Warehouse Modeling – Making the Right Choices

    - by Davide Mauri
    As you may have already learned from my old post or Adam’s or Kalen’s posts, there will be two SQL Rally in North Europe. In the Stockholm SQL Rally, with my friend Thomas Kejser, I’ll be delivering a pre-con on Data Warehouse Modeling: Data warehouses play a central role in any BI solution. It's the back end upon which everything in years to come will be created. For this reason, it must be rock solid and yet flexible at the same time. To develop such a data warehouse, you must have a clear idea of its architecture, a thorough understanding of the concepts of Measures and Dimensions, and a proven engineered way to build it so that quality and stability can go hand-in-hand with cost reduction and scalability. In this workshop, Thomas Kejser and Davide Mauri will share all the information they learned since they started working with data warehouses, giving you the guidance and tips you need to start your BI project in the best way possible?avoiding errors, making implementation effective and efficient, paving the way for a winning Agile approach, and helping you define how your team should work so that your BI solution will stand the test of time. You'll learn: Data warehouse architecture and justification Agile methodology Dimensional modeling, including Kimball vs. Inmon, SCD1/SCD2/SCD3, Junk and Degenerate Dimensions, and Huge Dimensions Best practices, naming conventions, and lessons learned Loading the data warehouse, including loading Dimensions, loading Facts (Full Load, Incremental Load, Partitioned Load) Data warehouses and Big Data (Hadoop) Unit testing Tracking historical changes and managing large sizes With all the Self-Service BI hype, Data Warehouse is become more and more central every day, since if everyone will be able to analyze data using self-service tools, it’s better for him/her to rely on correct, uniform and coherent data. Already 50 people registered from the workshop and seats are limited so don’t miss this unique opportunity to attend to this workshop that is really a unique combination of years and years of experience! http://www.sqlpass.org/sqlrally/2013/nordic/Agenda/PreconferenceSeminars.aspx See you there!

    Read the article

  • A Simple Guide to Web Programming Services

    The internet has evolved dramatically over the past 10 years or so. From simple static webpages containing no more than text and images, it has transformed to highly interactive content. It has come to the point that the web may very well be your virtual desktop. This article describes the basic foundation of these websites and what makes them tick.

    Read the article

  • How to recognize an optimus laptop?

    - by kellogs
    kellogs@kellogs-K52Jc ~ $ lspci 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 18) 00:02.0 VGA compatible controller: Intel Corporation Core Processor Integrated Graphics Controller (rev 18) 00:16.0 Communication controller: Intel Corporation 5 Series/3400 Series Chipset HECI Controller (rev 06) 00:1a.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 06) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 06) 00:1c.1 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 2 (rev 06) 00:1c.5 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 6 (rev 06) 00:1d.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev a6) 00:1f.0 ISA bridge: Intel Corporation Mobile 5 Series Chipset LPC Interface Controller (rev 06) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 4 port SATA AHCI Controller (rev 06) 00:1f.6 Signal processing controller: Intel Corporation 5 Series/3400 Series Chipset Thermal Subsystem (rev 06) 02:00.0 Network controller: Atheros Communications Inc. AR9285 Wireless Network Adapter (PCI-Express) (rev 01) 03:00.0 System peripheral: JMicron Technology Corp. SD/MMC Host Controller (rev 80) 03:00.2 SD Host controller: JMicron Technology Corp. Standard SD Host Controller (rev 80) 03:00.3 System peripheral: JMicron Technology Corp. MS Host Controller (rev 80) 03:00.4 System peripheral: JMicron Technology Corp. xD Host Controller (rev 80) 03:00.5 Ethernet controller: JMicron Technology Corp. JMC250 PCI Express Gigabit Ethernet Controller (rev 03) ff:00.0 Host bridge: Intel Corporation Core Processor QuickPath Architecture Generic Non-core Registers (rev 05) ff:00.1 Host bridge: Intel Corporation Core Processor QuickPath Architecture System Address Decoder (rev 05) ff:02.0 Host bridge: Intel Corporation Core Processor QPI Link 0 (rev 05) ff:02.1 Host bridge: Intel Corporation Core Processor QPI Physical 0 (rev 05) ff:02.2 Host bridge: Intel Corporation Core Processor Reserved (rev 05) ff:02.3 Host bridge: Intel Corporation Core Processor Reserved (rev 05) kellogs@kellogs-K52Jc ~ $ inxi -SGx System: Host: kellogs-K52Jc Kernel: 3.5.0-17-generic x86_64 (64 bit, gcc: 4.7.2) Desktop: KDE 4.9.5 (Qt 4.8.3) Distro: Linux Mint 14 Nadia Graphics: Card: Intel Core Processor Integrated Graphics Controller bus-ID: 00:02.0 X.Org: 1.13.0 drivers: intel (unloaded: fbdev,vesa) Resolution: [email protected] GLX Renderer: Mesa DRI Intel Ironlake Mobile GLX Version: 2.1 Mesa 9.0.3 Direct Rendering: Yes kellogs@kellogs-K52Jc ~ $ lshw [...] *-display description: VGA compatible controller product: Core Processor Integrated Graphics Controller vendor: Intel Corporation physical id: 2 bus info: pci@0000:00:02.0 version: 18 width: 64 bits clock: 33MHz capabilities: vga_controller bus_master cap_list rom configuration: driver=i915 latency=0 resources: irq:44 memory:d0000000-d03fffff memory:c0000000-cfffffff ioport:e080(size=8) Manufacturer advertises the K52Jc model which I bought as optimus enabled. However, no traces of it in the output above. Of course, Bumblebee would not start on this machine. Should I rest assured that is a defective / un-optimused machine ?

    Read the article

  • Terminal services printers/scanners?

    - by earlz
    Is there some list of printers/scanners that are known to work with Terminal Services or some way to determine automatically if the device will work from the specifications? I am needing to advise a customer on a small(as in, can set on a desk) all-in-one printer/scanner/fax that works with Terminal Services. The client OS is Windows XP, the server OS is Server 2003.

    Read the article

  • Building a distributed system on Amazon Web Services

    - by Songo
    Would simply using AWS to build an application make this application a distributed system? For example if someone uses RDS for the database server, EC2 for the application itself and S3 for hosting user uploaded media, does that make it a distributed system? If not, then what should it be called and what is this application lacking for it to be distributed? Update Here is my take on the application to clarify my approach to building the system: The application I'm building is a social game for Facebook. I developed the application locally on a LAMP stack using Symfony2. For production I used an a single EC2 Micro instance for hosting the app itself, RDS for hosting my database, S3 for the user uploaded files and CloudFront for hosting static content. I know this may sound like a naive approach, so don't be shy to express your ideas.

    Read the article

  • How to Create Features for Windows SharePoint Services 3.0

    To customise a SharePoint (WSS 3.0) site, you'll need to understand 'Features'. The 'Feature' framework has become the most important method of customising a SharePoint site, because it is now defined by a list of Features, a layout page and a master page. One templated site can be turned into another by toggling Features and maybe switching the layout page or master page. Charles Lee explains.

    Read the article

  • SolidQ Journal - free SQL goodness for February

    - by Greg Low
    The SolidQ Journal for February just made it out by the end of February 28th. But again, it's great to see the content appearing. I've included the second part of the article on controlling the execution context of stored procedures. The first part was in December. Also this month, along with Fernando Guerrero's editorial, Analysis Services guru Craig Utley has written about aggregations, Herbert Albert and Gianluca Holz have continued their double-act and described how to automate database migrations,...(read more)

    Read the article

  • Project Euler 11: (Iron)Python

    - by Ben Griswold
    In my attempt to learn (Iron)Python out in the open, here’s my solution for Project Euler Problem 11.  As always, any feedback is welcome. # Euler 11 # http://projecteuler.net/index.php?section=problems&id=11 # What is the greatest product # of four adjacent numbers in any direction (up, down, left, # right, or diagonally) in the 20 x 20 grid? import time start = time.time() grid = [\ [8,02,22,97,38,15,00,40,00,75,04,05,07,78,52,12,50,77,91,8],\ [49,49,99,40,17,81,18,57,60,87,17,40,98,43,69,48,04,56,62,00],\ [81,49,31,73,55,79,14,29,93,71,40,67,53,88,30,03,49,13,36,65],\ [52,70,95,23,04,60,11,42,69,24,68,56,01,32,56,71,37,02,36,91],\ [22,31,16,71,51,67,63,89,41,92,36,54,22,40,40,28,66,33,13,80],\ [24,47,32,60,99,03,45,02,44,75,33,53,78,36,84,20,35,17,12,50],\ [32,98,81,28,64,23,67,10,26,38,40,67,59,54,70,66,18,38,64,70],\ [67,26,20,68,02,62,12,20,95,63,94,39,63,8,40,91,66,49,94,21],\ [24,55,58,05,66,73,99,26,97,17,78,78,96,83,14,88,34,89,63,72],\ [21,36,23,9,75,00,76,44,20,45,35,14,00,61,33,97,34,31,33,95],\ [78,17,53,28,22,75,31,67,15,94,03,80,04,62,16,14,9,53,56,92],\ [16,39,05,42,96,35,31,47,55,58,88,24,00,17,54,24,36,29,85,57],\ [86,56,00,48,35,71,89,07,05,44,44,37,44,60,21,58,51,54,17,58],\ [19,80,81,68,05,94,47,69,28,73,92,13,86,52,17,77,04,89,55,40],\ [04,52,8,83,97,35,99,16,07,97,57,32,16,26,26,79,33,27,98,66],\ [88,36,68,87,57,62,20,72,03,46,33,67,46,55,12,32,63,93,53,69],\ [04,42,16,73,38,25,39,11,24,94,72,18,8,46,29,32,40,62,76,36],\ [20,69,36,41,72,30,23,88,34,62,99,69,82,67,59,85,74,04,36,16],\ [20,73,35,29,78,31,90,01,74,31,49,71,48,86,81,16,23,57,05,54],\ [01,70,54,71,83,51,54,69,16,92,33,48,61,43,52,01,89,19,67,48]] # left and right max, product = 0, 0 for x in range(0,17): for y in xrange(0,20): product = grid[y][x] * grid[y][x+1] * \ grid[y][x+2] * grid[y][x+3] if product > max : max = product # up and down for x in range(0,20): for y in xrange(0,17): product = grid[y][x] * grid[y+1][x] * \ grid[y+2][x] * grid[y+3][x] if product > max : max = product # diagonal right for x in range(0,17): for y in xrange(0,17): product = grid[y][x] * grid[y+1][x+1] * \ grid[y+2][x+2] * grid[y+3][x+3] if product > max: max = product # diagonal left for x in range(0,17): for y in xrange(0,17): product = grid[y][x+3] * grid[y+1][x+2] * \ grid[y+2][x+1] * grid[y+3][x] if product > max : max = product print max print "Elapsed Time:", (time.time() - start) * 1000, "millisecs" a=raw_input('Press return to continue')

    Read the article

  • How should I set up protection for the database against sql injection when all the php scripts are flawed?

    - by Tchalvak
    I've inherited a php web app that is very insecure, with a history of sql injection. I can't fix the scripts immediately, I rather need them to be running to have the website running, and there are too many php scripts to deal with from the php end first. I do, however, have full control over the server and the software on the server, including full control over the mysql database and it's users. Let's estimate it at something like 300 scripts overall, 40 semi-private scripts, and 20 private/secure scripts. So my question is how best to go about securing the data, with the implicit assumption that sql injection from the php side (e.g. somewhere in that list of 300 scripts) is inevitable? My first-draft plan is to create multiple tiers of different permissioned users in the mysql database. In this way I can secure the data & scripts in most need of securing first ("private/secure" category), then the second tier of database tables & scripts ("semi-private"), and finally deal with the security of the rest of the php app overall (with the result of finally securing the database tables that essentially deal with "public" information, e.g. stuff that even just viewing the homepage requires). So, 3 database users (public, semi-private, and secure), with a different user connecting for each of three different groups of scripts (the secure scripts, the semi-private scripts, and the public scripts). In this way, I can prevent all access to "secure" from "public" or from "semi-private", and to "semi-private" from "public". Are there other alternatives that I should look into? If a tiered access system is the way to go, what approaches are best?

    Read the article

  • FTP Reporting Disk Quota Exceeded

    - by Austin
    I am using Notepad++ with FTP_Synchronize to upload files to a server, however, it appears that it is not allowing my file to upload because apparently the "Disk Quota Exceeded" 11:18:49 > -> TYPE I 11:18:49 > Response (200): Type set to I 11:18:49 > -> PASV 11:18:49 > Response (227): Entering Passive Mode (*,*,*,*,*,*). 11:18:50 > -> STOR /home/*/../../var/www/html/test.html 11:18:50 > Response (150): Opening BINARY mode data connection for /home/*/../../var/www/html/test.html 11:18:50 > Response (552): Transfer aborted. Disk quota exceeded Now it may appear that yeah my Disk quota is exceeded, however I've gone to the back-end and saw: Total Used Bandwidth 107.055 MB Allowed Quota 3,000.0 MB Note: Stars were put in place for irrelevant data.

    Read the article

  • How do I connect Ubuntu to Sony Bravia LED TV via HDMI?

    - by VedVals
    My laptop connects to 46" Sony Bravia LED TV using HDMI cable in Windows without any problem. However, it just doesn't work with Ubuntu 12.04. It always says No Signal. Problem somewhat persists after upgrading to 13.04. Bravia detects my laptop as a connection now but I am unable to display anything. What drivers/applications should I install to connect via HDMI? Output of sudo lspci -nn : 00:00.0 Host bridge [0600]: Intel Corporation 2nd Generation Core Processor Family DRAM Controller [8086:0104] (rev 09) 00:01.0 PCI bridge [0604]: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port [8086:0101] (rev 09) 00:02.0 VGA compatible controller [0300]: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller [8086:0116] (rev 09) 00:16.0 Communication controller [0780]: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 [8086:1c3a] (rev 04) 00:1a.0 USB controller [0c03]: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 [8086:1c2d] (rev 05) 00:1b.0 Audio device [0403]: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller [8086:1c20] (rev 05) 00:1c.0 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 [8086:1c10] (rev b5) 00:1c.1 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 2 [8086:1c12] (rev b5) 00:1c.3 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 4 [8086:1c16] (rev b5) 00:1c.4 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 5 [8086:1c18] (rev b5) 00:1c.5 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 6 [8086:1c1a] (rev b5) 00:1d.0 USB controller [0c03]: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 [8086:1c26] (rev 05) 00:1f.0 ISA bridge [0601]: Intel Corporation HM67 Express Chipset Family LPC Controller [8086:1c4b] (rev 05) 00:1f.2 SATA controller [0106]: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller [8086:1c03] (rev 05) 00:1f.3 SMBus [0c05]: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller [8086:1c22] (rev 05) 01:00.0 VGA compatible controller [0300]: NVIDIA Corporation GF108M [GeForce GT 525M] [10de:0df5] (rev ff) 03:00.0 Network controller [0280]: Intel Corporation Centrino Wireless-N 1030 [Rainbow Peak] [8086:008a] (rev 34) 04:00.0 USB controller [0c03]: NEC Corporation uPD720200 USB 3.0 Host Controller [1033:0194] (rev 04) 06:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8111/8168 PCI Express Gigabit Ethernet controller [10ec:8168] (rev 06)

    Read the article

< Previous Page | 427 428 429 430 431 432 433 434 435 436 437 438  | Next Page >