Search Results

Search found 503 results on 21 pages for 'cables'.

Page 5/21 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • 2 x Netgear GS724T (Dual GBIC) trunking issue

    - by Arthor
    I have the following: Netgear GS724T (Firmware Version V1.0.3_35, Protocol Version - 2.001.002) 4 x Indineon ISFP GBR/FC Settings STP Function - Enabled Fast Link - Enabled Trunking port 23,24, (21,22 - RJ45 cables, but not connected.) I have connected both switches via 2 fiber cables and want to use trunking. The problem I am having. Sometimes I get a an issue when none of the switches cannot talk with each other, nor the devices, sometime they can. The problem is irregular and no patten can be determined The statistics shows that when the switches does not work, they have RX errors If I remove one to the GBIC connections, then everything works as normal.] Question Does anyone have a solution for this please? Thanks

    Read the article

  • Computer to Tv cable question

    - by Keith D
    Hi all. Heres my query : I have a PC with all the usual outputs and a couple of TVs in the house with inputs to connect to a computer. Now, what i would like to do is get rid of cable TV and using the input into the spliters in the basement,( ie. where the input cable from outside actually feeds the system ) have the computer become the "Cable supplier" ( so to speak ) and have the output ( via some sort of box ) from the computer, convert what is on my monitor into an RF signal that is then fed into the cables in my house and ultimately to each TV / room . I don't know if there is such an item but would welcome any thoughts you might have on such a set up. I am not into HD or the like, so the picture quality needs only to be watchable, not HD. I don't want to have to set up seperate cables to feed the audio on each TV. Thanks in advance!

    Read the article

  • Mouse Icon Distorted on Secondary Display

    - by Nathan Taylor
    I have a strange issue with a dual monitor, extended desktop setup where the mouse is always fine on the primary monitor, but sometimes when I move to the secondary display the icon becomes garbled and distorted (sometimes it just looks like a vertical line, instead of a pointer). If I move the mouse back and forth rapidly between primary and secondary displays the level of "garbledness" of the icon will change and sometimes go away completely. If I switch the display settings and set it to "Duplicate Monitor 1" then I end up with a garbled icon on the primary display and an accurate one on the secondary. Very annoying. Computer is Windows 7 Ultimate with an HD8750 and the newest video drivers. Monitors are two Dell 24" displays connected via DVI cables. I have also tried VGA cables.

    Read the article

  • Cat 6 Only 100mbit speed

    - by Stu2000
    I tried two different cat6 cables directly connected between my two ubuntu machines. This one I ordered online: http://www.amazon.co.uk/gp/product/B002SQPDXS/ref=wms_ohs_product only achieves 100mbit speeds, but does appear to be supporting cross-talk (direct pc to pc), the other cat 6 cable, worked perfectly and gets the full 1gigabit speed. Both tests were performed using ftp and checking the network monitor with direct pc to pc connection. Did the product from amazon lie to me or do I need to manually set a setting somewhere in ubuntu for some cables? I had thought 10 quid for 20m of gigabit ethernet cable was a bit cheap, you get what you pay for... Regards, Stu Update: It seems that after rebooting, the device is set to 1000mbit sec when looking it up with sudo ethtool eth0 However after a while, this will drop down to just 100, after which to reset it to 1000 again, I have to reboot, and simply unpugging and re-plugging in the cable doesn't do it. I tried setting this in networking config file as suggested here: auto eth0 iface eth0 inet static pre-up /usr/sbin/ethtool -s eth0 speed 1000 duplex full but that resulted in my networking failing to start. Is there a problem with my 'auto-negotiation' or something? Can I manually override a setting to 1000mbit?

    Read the article

  • System fan connection on Mini-ITX server case and motherboard

    - by Robert
    The case: Newegg listing for Chenbro ES34169-BK-120 The motherboard: GIGABYTE GA-D525TUD (Newegg has it as well but I can't post more than one link due to being a new user) As far as the question, the system fan I have no idea how to get these to connect to the motherboard. There are two connectors which then go to extension fan cables. So when you connect these, it should be good, but the extension cables are two connectors that go to the system fans and a female molex connector (if you click the Chenbro listing, look at the 6th picture and you'll see the two connections being made and the molex connector just kind of hanging out in the case). Is there a piece I'm missing to get it to connect to the 3 pin sys_fan section of the board? Thanks,

    Read the article

  • Cable management between multiple racks

    - by RippieUK
    I am in the planning phase of re-cabling our 5 racks in one of our offices and I would like to ask for some guidance on how you go, or would go about managing cables that goes between racks. In our situation we have 5 racks where the furthest to the right is our main patch panel for 300 floor ports. The rack next to it is our main comms rack where main switches and ISP routers are located. the other 3 racks next to the comms rack then all need to connect back to the main comms rack. I am not sure if a 48 port patch panel in each rack would be any good for this scenario? mainly because i am not sure this can be linked back to the main switch with only 1 cable. Would a 48 port switch in each rack be better as you can uplink those back to main switch? Or should we just run cables between racks back to the main switch? Hope someone can offer some guidiance. Thx

    Read the article

  • Intel SASWT4I SAS/SATA Controller Question

    - by Joe Hopfgartner
    Hey there! I want to assemble a cheap storage sytem based on the Norco RPC-4020 Case. When searching for controllers I found this one: Intel® RAID Controller SASWT4I This is a quote form the Spec Sheet: Scalability. Supports up to 122 physical devices in SAS mode which is ideal for employing JBODs (Just a Bunch Of Disks) or up to 14 devices in RAID 0, 1, 1E/10E mode through direct connect device attachment or through expander backplane support. Does that mean I can attatch 14 SATA drives directly to the controller using SFF-8087 - 4x SATA breakout cables? That would be nice because then I can choose a mainboard that has 6 Onboard SATA and i can connect all 20 bays while only spending 155$ on the controller and like another 100$ on cables. Would that work? And why is it 14 and not 16 when there are 4 Ports? I am really confused about all the breakout/fanout/(edge-)expanding/multiplying/channel stuff...

    Read the article

  • some questions about raid card

    - by cpps
    I have some questions about raid card. Use LSI MegaRAID® SAS 9260-8i raid card as a example. There is only two connection ports on the raid card, and they provide two cables that can connect 8 SAS/SATA storages. The document say it can connect "Maximum 32 drives per controller", I want to know how can I connect more than 8 hard disks with this card. Is that they say "Eight internal SATA+SAS ports" means they provide two cables which can connect 8 hard drives, but you can use other way to connect Maximum 32 drives? The other question. I see host bus adapter has raid integrated , so what is the difference between host bus adapter and raid card. Are they the same? I also know is SAS/SATA Expander's function only to connect more hard drives? Thanks in advance.

    Read the article

  • New power supply and now HDDs are not recognized

    - by Michael
    So I upgraded to a new X4 ULTRA power supply that was recommended to me by a local TigerDirect store. After installing it along with a new liquid cooling system, I booted it up and it automatically fried my CD Drive. After that I noticed that the OS wouldn't start and figured out that none of the 4 HDDs in my computer were being recognized by the BIOS. I feel them spool at a steady pace and have tried new cables and connections but to no avail. I triple checked all of the connections and cables and have no idea what is wrong. This isn't the first time I changed a PS or CPU cooling system but I am at a dead end. Any ideas, aside from buying a USB HDD reader and seeing if they are all fried? Also, this is a stock Gateway mobo with the mobo USB connections already dead. Could the new PS have fried the SATA connections??

    Read the article

  • Upgrading HP DL185 G5 8LFF, is using a Dell J1520 4-Drop SATA Adapter possible?

    - by jpreed00
    The HP DL185 G5 8LFF model supports 8 3.5" drives and 1 optical drive. However, instead of the optical drive, I'd like to have 2x 2.5" drives instead. The problem is that the PSU has no more SATA power cables (even though the motherboard has 4 additional SATA data ports). The PSU does have a free 10-pin connector and it looks like the J1520 cable from Dell would fit the bill. Link to cable description Does anyone have any experience using these cables? Are they safe? Any other ideas for adding the disks to the server if I don't use the cable? Thanks!

    Read the article

  • Can I use CAT 6a connectors with 7a cable (and get 6a performance)?

    - by Mr. Flibble
    I'm re-wiring a building and want to get the best cable possible laid - it required re-plastering to make a change to the cables and the cables will be there for the next 10 - 20 years. Currently there appears to be cat 7a cable available but not too much in the way of cat 7a connectors. Also - I won't be using 40Gig hardware in the near future. So, my question: is it possible to use cat 6a connectors / patch panels with cat 7a cable and get the same performance as I would had I used cat 6a cable? Are there any gotchas in trying to do this?

    Read the article

  • Share ADSL Internet connection between two computers 40 meters away (straight) from each other

    - by dario_ramos
    I have a box with a working ADSL Internet connection. About 40 meters away (straight), in another house, there is another, older box. There are two houses in between. Would there be some practical way to supply an Internet connection to the older box? The neighbors are ok with us installing cables and stuff. I'd say wifi would not be practical, since the houses in between would weaken the signal too much. And using Ethernet cables might require a switch or router in between, due to Ethernet distance limitations. Advice?

    Read the article

  • How to interconnect laptop, PC, Android & Symbiam phones with WiFi?

    - by noquery
    What I have Level One wifi Router hub Laptop with Windows 7 (wifi enabled) Desktop PC with Windows 7 (with no wifi, maybe LAN cables can help) 2 android & 1 Symbian Phones each wifi enabled. LAN Cables Hathway Internet connection which allows only 1 login to access internet What I want Is it possible to access internet on PC, laptop, mobiles at the same time with only one connection? Since I don't know even A of networking so please suggest some software which require minimum cofiguration. Let me know if any other hardware I require.

    Read the article

  • How to switch easily between a 5.1 headset and 2.1 speakers ?

    - by Wookai
    I have a 5.1 headset that I mostly use for gaming and watching movies. It is connected using 3 jacks to the rear panel of my motherboard (plus one for the microphone). I also have some small 2.1 speakers that I sometimes use to listen to music or to share a video/movie with someone. For now, what I do is crawl under my desk, and switch the cables. As my motherboard has 7.1 capabilities, I am wondering if there could be a way of having all 4 jack cables always plugged in, and switching on which device to output the sound programmatically. Has anybody had a similar problem, and how did you solve it ?

    Read the article

  • Asus V1S screen dimming randomly

    - by Bill
    I have an Asus V1V, which is the same as the Asus V1S except for the video card. I have a problem where the screen will randomly lose brightness or flicker between being lit and not lit. The picture below is of the left hinge, with the cover removed. Pressing one of these cables affects this behaviour, and pressing it in place will resolve the issue for a few hours. My guess means the inverter cable is damaged, based on previous experience. As the picture shows, there are two cables, an LCD cable and what I assume is an inverter cable. I purchased an LCD cable for my model of laptop, but have been unable to find an inverter cable. It seems not to exist. I would like some input on if an inverter cable actually exists, if it is likely the problem, or solutions in general to resolve this problem permanently.

    Read the article

  • How to "get" a reliable parallel port on a laptop without a PCMCIA slot?

    - by ldigas
    Usb-Parallel port (for an old, but reliable matrix printer that has its special use) connections (cables) are unreliable. They sometimes work, sometimes don't - and since I installed Windows 7 I can't get neither of my old ones to work properly. PCMCIA is usually considered (and it is) a much more reliable solution, but unfortunatelly, none of my new laptops has a PCMCIA slot. So, all ideas are welcomed. What should I do? I'm open to all suggestions as long as you have some experience that they work more reliably than USB-Parallel cables and their wicked drivers.

    Read the article

  • No SATA drives after PSU Upgrade

    - by hauptbenutzer
    I know this sounds a lot like this but I just confirmed that my MBR is fine as well as the SSD drive in question. What happened: I upgraded my be-quiet 700w PSU to the 1000w dark power pro. When I tried booting the system and none of the drives (all SATA) were detected, resulting in the "Boot device failure" error. After that I unplugged all but the boot drive, triple checked that all cables were in fact nice and tight inside their sockets, replaced both e-SATA and power cables ; still with the same outcome. Finally I reconnected my old PSU and sure enough the PC booted without any hassle (except of course for the direful construction that is currently occupying my desk). Does anybody have any advice on how to proceed? Surely, it is possible the PSU is faulty but are there other explanations? Thanks in advance PS. if of any help: Motherboard is GIGABYTE GA-PH67A-UD3-B3 H67 LGA 1155

    Read the article

  • Windows Server 2008 R2 network adapter stops working, requires hard reboot

    - by Geoff Dalgas
    TL;DR version: Turns out this was a Windows Server 2008 R2 kernel networking bug. After siccing Microsoft support on it, we (eventually) got an unpublished kernel hotfix from Microsoft to address it. If you, too, are experiencing mysterious low-level network driver failures requiring a reboot/bluescreen cycle, you might want that hotfix (or maybe Service Pack 1 whenever it is released, too.) We have been using HAProxy along with heartbeat from the Linux-HA project. We are using two linux instances to provide a failover. Each server has with their own public IP and a single IP which is shared between the two using a virtual interface (eth1:1) at IP: 69.59.196.211 The virtual interface (eth1:1) IP 69.59.196.211 is configured as the gateway for the windows servers behind them and we use ip_forwarding to route traffic. We are experiencing an occasional network outage on one of our windows servers behind our linux gateways. HAProxy will detect the server is offline which we can verify by remoting to the failed server and attempting to ping the gateway: Pinging 69.59.196.211 with 32 bytes of data: Reply from 69.59.196.220: Destination host unreachable. Running arp -a on this failed server shows that there is no entry for the gateway address (69.59.196.211): Interface: 69.59.196.220 --- 0xa Internet Address Physical Address Type 69.59.196.161 00-26-88-63-c7-80 dynamic 69.59.196.210 00-15-5d-0a-3e-0e dynamic 69.59.196.212 00-21-5e-4d-45-c9 dynamic 69.59.196.213 00-15-5d-00-b2-0d dynamic 69.59.196.215 00-21-5e-4d-61-1a dynamic 69.59.196.217 00-21-5e-4d-2c-e8 dynamic 69.59.196.219 00-21-5e-4d-38-e5 dynamic 69.59.196.221 00-15-5d-00-b2-0d dynamic 69.59.196.222 00-15-5d-0a-3e-09 dynamic 69.59.196.223 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 225.0.0.1 01-00-5e-00-00-01 static On our linux gateway instances arp -a shows: peak-colo-196-220.peak.org (69.59.196.220) at <incomplete> on eth1 stackoverflow.com (69.59.196.212) at 00:21:5e:4d:45:c9 [ether] on eth1 peak-colo-196-215.peak.org (69.59.196.215) at 00:21:5e:4d:61:1a [ether] on eth1 peak-colo-196-219.peak.org (69.59.196.219) at 00:21:5e:4d:38:e5 [ether] on eth1 peak-colo-196-222.peak.org (69.59.196.222) at 00:15:5d:0a:3e:09 [ether] on eth1 peak-colo-196-209.peak.org (69.59.196.209) at 00:26:88:63:c7:80 [ether] on eth1 peak-colo-196-217.peak.org (69.59.196.217) at 00:21:5e:4d:2c:e8 [ether] on eth1 Why would arp occasionally set the entry for this failed server as <incomplete>? Should we be defining our arp entries statically? I've always left arp alone since it works 99% of the time, but in this one instance it appears to be failing. Are there any additional troubleshooting steps we can take help resolve this issue? THINGS WE HAVE TRIED I added a static arp entry for testing on one of the linux gateways which still didn't help. root@haproxy2:~# arp -a peak-colo-196-215.peak.org (69.59.196.215) at 00:21:5e:4d:61:1a [ether] on eth1 peak-colo-196-221.peak.org (69.59.196.221) at 00:15:5d:00:b2:0d [ether] on eth1 stackoverflow.com (69.59.196.212) at 00:21:5e:4d:45:c9 [ether] on eth1 peak-colo-196-219.peak.org (69.59.196.219) at 00:21:5e:4d:38:e5 [ether] on eth1 peak-colo-196-209.peak.org (69.59.196.209) at 00:26:88:63:c7:80 [ether] on eth1 peak-colo-196-217.peak.org (69.59.196.217) at 00:21:5e:4d:2c:e8 [ether] on eth1 peak-colo-196-220.peak.org (69.59.196.220) at 00:21:5e:4d:30:8d [ether] PERM on eth1 root@haproxy2:~# arp -i eth1 -s 69.59.196.220 00:21:5e:4d:30:8d root@haproxy2:~# ping 69.59.196.220 PING 69.59.196.220 (69.59.196.220) 56(84) bytes of data. --- 69.59.196.220 ping statistics --- 7 packets transmitted, 0 received, 100% packet loss, time 6006ms Rebooting the windows web server solves this issue temporarily with no other changes to the network but our experience shows this issue will come back. Swapping network cards and switches I noticed the link light on the port of the switch for the failed windows server was running at 100Mb instead of 1Gb on the failed interface. I moved the cable to several other open ports and the link indicated 100Mb for each port that I tried. I also swapped the cable with the same result. I tried changing the properties of the network card in windows and the server locked up and required a hard reset after clicking apply. This windows server has two physical network interfaces so I have swapped the cables and network settings on the two interfaces to see if the problem follows the interface. If the public interface goes down again we will know that it is not an issue with the network card. (We also tried another switch we have on hand, no change) Changing network hardware driver versions We've had the same problem with the latest Broadcom driver, as well as the built-in driver that ships in Windows Server 2008 R2. Replacing network cables As a last ditch effort we remembered another change that occurred was the replacement of all of the patch cords between our servers / switch. We had purchased two sets, one green of lengths 1ft - 3ft for the private interfaces and another set of red cables for the public interfaces. We swapped out all of the public interface patch cables with a different brand and ran our servers without issue for a full week ... aaaaaand then the problem recurred. Disable checksum offload, remove TProxy We also tried disabling TCP/IP checksum offload in the driver, no change. We're now pulling out TProxy and moving to a more traditional x-forwarded-for network arrangement without any fancy IP address rewriting. We'll see if that helps. Switch Virtualization providers On the off chance this was related to Hyper-V in some way (we do host Linux VMs on it), we switched to VMWare Server. No change. Switch host model We've reached the end of our troubleshooting rope and are now formally involving Microsoft support. They recommended changing the host model: http://en.wikipedia.org/wiki/Host_model http://technet.microsoft.com/en-us/magazine/2007.09.cableguy.aspx We did that, and.. we'll see.

    Read the article

  • Des pays proposent que l'ONU soit chargé de « maintenir l'ordre sur Internet », dont la Chine, l'Inde et l'Arabie Saoudite

    Des pays proposent que l'ONU soit chargé de « maintenir l'ordre sur Internet » Dont la Chine, l'Inde et l'Arabie Saoudite Le conseil des Nations Unis pourrait réagir suite à l'affaire Wikileaks, le site polémique qui continue de publier quotidiennement des câbles forts embarrassants pour les diplomaties du monde entier. Le conseil étudie en effet une proposition qui vise à créer un groupe de travail inter-gouvernemental dont le but serait d'harmoniser les efforts des décideurs pour "maintenir l'ordre" sur Internet. Cette proposition émane d'un groupe de plusieurs pays menés par le Brésil et...

    Read the article

  • How to configure 2 lan cards?

    - by Gurupal singh
    I have Ubuntu 14.04 installed on my system and i make it as a server in my office with having 15 employees working.I have 2 Lan cards in my system, one for input from router to my ubuntu server and other from my system to switch, which connects all my employees from through that switch via lan cables.Now, how can i configure my both LAN cards, as i wants to block some sites and make some restriction on the network. Please help me out. It's really a big problem for me. Thanks.

    Read the article

  • Exadata X3 Expandability Update

    - by Bandari Huang
    Exadata Database Machine X3-2 Data Sheet New 10/29/2012 Up to 18 racks can be connected without requiring additional InfiniBand switches. Exadata Database Machine X3-8 Data Sheet New 10/24/2012 Scale by connecting multiple Exadata Database Machine X3-8 racks or Exadata Storage Expansion Racks. Up to 18 racks can be connected by simply connecting via InfiniBand cables. Larger configurations can be built with additional InfiniBand switches.  

    Read the article

  • Explore What';s Inside of a Fiber Optic Cable

    Fiber optic cable (or optical fiber) is unlike most types of cables; it draw on light instead of electricity to transmit signals. As you have already known, light is the fastest method of transmittin... [Author: Rahim Bidgoli - Computers and Internet - April 02, 2010]

    Read the article

  • La norme USB 3.1 enfin finalisée signe l'arrivée des débits atteignant les 10 Gbps

    La norme USB 3.1 enfin finalisée signe l'arrivée des débits atteignant les 10 GbpsL'arrivée de la nouvelle norme USB 3.1 a été annoncée sur le forum USB. Voici quelques caractéristiques clés marquant cette évolution : augmentation du débit qui est désormais de 10 Gbps (au lieu de 5 Gbps) ; compatibilité avec les connecteurs et câbles actuels ; amélioration de l'encodage des données ; compatibilité avec la surcouche logicielle USB 3.0 existante ; maintien de la rétrocompatibilité USB 3.0 5 Gbps/USB 2.0.

    Read the article

  • How to create/extract the EDID for/from a Monitor

    - by Luis Alvarado
    Is it possible to create or extract the Extended Display Identification Data (EDID) for/from a monitor. I have some issues with my monitor with the VGA and HDMI cables and I would like to test if by adding the EDID to the Nvidia Settings it could help in solve this issues. With the VGA cable I get a black out error and with the HDMI I get some EDID errors (bad EDID). So how can I create the EDID or extract it from the monitor by detecting its capabilities.

    Read the article

  • Do you ?Get What You Pay For? In A Cable?

    We?ve all heard the phrase ?you get what you pay for? in regards to different products: televisions, computers, car audio systems. The question is, does this rule apply to cables? To some extent it c... [Author: Andrew Lang - Computers and Internet - March 27, 2010]

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >