Search Results

Search found 15344 results on 614 pages for 'layout manager'.

Page 512/614 | < Previous Page | 508 509 510 511 512 513 514 515 516 517 518 519  | Next Page >

  • Intel DriverInstall issue on HP ProLiant server DL580G5

    - by TomTom
    Given: A HP ProLiant server to be used for Hyper-V server (R 2) Problem: The server has a HP NC364T quad port card, which actually is an Intel 1000 Pro adapter. We are stuck getting this adapter properly working. We need to get it working with: 2 trunks of 2 ports each one of them fully vlan "aware" (without filtering anything - so that Hyper-V can do the VLAN filtering). So far we did: Install the server Install latest PSP. Problem here - tool does not work to set up teaming. We tried to install the latest ProWin pack from Intel - the drivers there are a LOT more current (26th of Marrch 2010, 9.13.41.0). The intalled driver (Microsoft) is ancient (march 2009, 9.13.4.10) A driver update fails both on command line (pnputil) as well as the PortLock device manager executable. No informatoin is provided. the ANS toolset can not create teams (fails with error - again, no reason provided), I know of no logs and the event log has no information either. Questions: What are the best drivers to use? How do we actually install them? How can we then set up teaming and how do we set up the VLAN behavior wanted?

    Read the article

  • SQL Server restore a backup results in an error.

    - by Mario
    I have a database in dev (SQL Server 2005 on Windows Server 2008) that I need to move to prod (SQL Server 2000 on Windows Server 2003). My process is as follows: Login to dev, open SQL Server Management Studio Right click on the database | Tasks | Backup. Keep all default options (full backup etc.) Move .bak file locally to prod (no network drive), login to prod, open SQL Server Enterprise Manager. Right click Databases node | All Tasks | Restore database. Change Restore as database to reflect the same database name. Click radio button 'From device'. Click 'Select Devices' Click Restore from: Add..., browse to .bak file (small - only 6mb) Now I am ready to restore the database, so I click OK and get the following error: "The media family on device 'E:...bak' is incorrectly formed. SQL Server cannot process this media family. RESTORE DATABASE is terminating abnormally." This error is immediate. I have tried a few different variations of this - restoring the db to dev machine with a different db name and log file names (where it originated), creating an empty database with the same physical path to files before and trying to restore to that, making a few different .bak files and making sure they are verified before uploading them to prod. I know for a fact the directory for the .mdf and .ldf files exist on prod, though the files themselves don't exist. If, before I click OK to restore, go to the options tab instead I get the following error: Error 3241: The media family on device 'E:...bak' is incorrectly formed. SQL Server cannot process this media family. RESTORE FILELIST is terminating abnormally. Anyone have any bright ideas?

    Read the article

  • Windows XP - Power surge on hub port

    - by Swift-Tuttle
    Since last few weeks I constantly get this error, as status bar balloon: Power Surge on Hub Port - A USB device has exceeded the power limits of its hub port. Due to this now I am unable to access any USB devices properly, they get disconnected intermittently. I did quite a few things to resolve this problem, firstly obviously through the Windows help. I even tried all the things told on the Microsoft website(which essentially says is to check and update the driver) but in vain. One suggestion, I found when I google'd was to disable the USB2 controller through the Device Manager and since at every startup the System configuration comes up complaining that it has been changed etc.(On that same site it is mentioned to ignore this message.) But after everything I still cant solve this problem. Any help is much appreciated. The system is installed with Windows XP service Pack 3 and all the updates till last month. Please let me know if any other hardware info is required. **UPDATE** My laptop is about 5 years old now, its an HP with Celeron 1.4G processor. Windows XP SP3 installed. All latest windows updates installed. 2 USB ports available. BIOS is HP 68DTD ver F.0A Do I need to update my BIOS from somewhere ? or is this a hardware problem altogether?

    Read the article

  • Confused about the Windows 7 Preinstallation Kit

    - by David Brown
    I build custom PCs and would like to use the Windows 7 Preinstallation Kit to make installation go a little quicker and customize the Windows image. However, since each PC is built to a particular customer's specifications, the hardware will rarely be the same. So, I would like to have a single answer file that will work for everything. I'm not sure if that's possible, however. What I mostly want to do for now is add my support information as well as pre-set anything that I would normally change after each installation completes. I have a Windows 7 Professional Upgrade DVD set (both 32-bit and 64-bit), but no OEM disks. I copied the Install.wim file to my local drive and opened it in the Windows System Image Manager, but it asks me to choose a catalog file specifically for each edition of Windows 7. Will this limit the answer file to whichever edition I choose? I would think choosing Starter would give me the most basic settings, which would apply to all other editions, but I'm not entirely sure of this. I don't intend to install any extra applications or drivers. I merely want to insert an OEM disk, my OPK USB drive, and have it work for whatever edition of Windows 7 I'm installing. If a large number of similarly-configured PCs need to be built, I'll go ahead and create a custom answer file in that case, but for a single machine order, that seems like overkill. In addition, do I need a separate answer file for 32-bit and 64-bit versions of Windows 7? Or will it work for both, even though I copied the Install.wim file from the 32-bit disk? Thanks!

    Read the article

  • Java Deployment Ruleset not working

    - by adbertram
    I've created a Java Deployment Ruleset that looks like this: <ruleset version="1.0+"> <rule> <id location="http://hpfweb.mydomain.com/" /> <action permission="run" version="1.6.0_20" /> </rule> <rule> <id location="http://*.mydomain.com" /> <action permission="run" /> </rule> <rule> </ruleset> I've created a self-signed cert, added it into the keystore as well as Trusted Certification Authorities. I have an app at http://hpfweb.mydomain.com that requires Java v1.6.20 and will error out if any other version is attempted. When only this version is installed on the computer the application works. However, if a newer version is installed, it does not. As you can see, I've attempted to force the version to 1.6.0_20 in the ruleset. I've confirmed the deployment rule set is being applied successfully by going into the Java Control Panel -- Security and "view the active deployment rule set". It is exactly as you see here. I've also looked at the web source for the application and all references point to http://hpfweb* links. When the applet is launched I've brought up task manager and have confirmed the java.exe launched is coming from the jre6 directory. When the newer version is installed, I'm getting the error "accesscontrolexception - access denied (java.awt.AWTPermission.accessEventQueue".

    Read the article

  • Is it possible to get CCM Updates Schedule using Powershel or VBScript?

    - by frogman
    I want to be able to check the CCM Updates Schedule as seen in Configuration Manager Updates tab. I've been looking around on google and I've not been able to find a consistent answer to this. I tried to create a COM object using UDA.CCMUpdatesDeployment. This allows me to successfully set the recurring schedule with SetUserDefinedSchedule method. If I try to use GetUserDefinedSchedule I only get the original values of the variables. PS> $UD = New-Object -com "UDA.CCMUpdatesDeployment" PS> $A= 101 PS> $B= 102 PS> $UD.GetUserDefinedSchedule([ref]$A, [ref]$B) PS> $A 101 PS> $B 102 PS> $UD.GetUserDefinedSchedule MemberType : Method OverloadDefinitions : {void GetUserDefinedSchedule (Variant, Variant)} TypeNameOfValue : System.Management.Automation.PSMethod Value : void GetUserDefinedSchedule (Variant, Variant) Name : GetUserDefinedSchedule IsInstance : True I actually want to be able to do this remotely for a list of servers in a text file but right now any way would do.

    Read the article

  • Issue resolving names on Hyper-V guest with Routing and Remote Access

    - by John Sheehan
    I've got a Win2k8 standard server running Hyper-V with a Server 2003 web guest instance running. The host is publicly available on the internet. I've created an Internal Private network in the Hyper-V Virtual Network manager. I've set the host IP for that virtual adapter to 192.168.0.1. I've set the IP on the guest to 192.168.0.2. They can ping each other and share files. I can't browse the web on the guest though. NSLOOKUPs are working. I've tried setting the DNS server setting on the guest to 192.168.0.1 and something external like Google's 8.8.8.8 server to no avail. Windows firewall is disabled on the internal virtual network. I've tried it with both DNS installed on the host and without it. I'm not sure which RRAS/NAT settings are relevant to pass on so ask if you need me to clarify anything. How do I get outbound internet working on the guest VM?

    Read the article

  • Removing SCIM input method as default from gnome terminal

    - by Mark
    Hello - I am recently back into the Linux world after about a 10 year absence. While I can find my way around most things, terminals and desktop managers are different than I remember. One of the biggest problems that I am encountering today is that when running a gnome terminal (this is Suse 10.0 enterprise), I'm getting behavior in the window that I don't want. Specifically, when I type, my typing is underlined as if something is trying to spell check my window. Further, it seems as if when running vi or less, my keystrokes are only processed by these apps when I hit 'return'. I.e. if I'm running less and want to go back a page, I'll hit b, but nothing happens until I hit 'return'. I seem to have tracked this down to the 'input method". Right clicking in the Gnome terminal allows me to set my input method to one of a dozen values. It seems that currently, it's set to "SCIM Input Method". If I then select 'default' or 'X Input Method', apps (i.e. things like less, vi, and even the bash shell) behave as I would expect. Can someone tell me a) what is this SCIM input method b) how can I make it so that it is not the default? I've poked around various configuration files in my home directory as well as in /etc, but I can't see to find how this is set. I guess as a final question, can I just get rid of SCIM? Or is that tied into the window manager somehow? I do appreciate any clarifications that I can get. Thanks.

    Read the article

  • Recommendations for good FTP server for Win 2008 x64

    - by sfhtimssf1970
    I spent a bunch of time learning/configuring the "all new and better" FTP feature for IIS7. In my opinion, it still fails hard: In order to have multiple FTP sites on the same machine, you have to use host|user usernames (like domain.com|jason) for every account. Using IIS Manager auth doesn't seem to work at all. I'm sure I'm doing something wrong, but I can't figure out what the hell it is. I've read all the official articles on it and configured it a hundred different ways. Doesn't play well with passive connection types. That has to be disabled on the client in order for it to work. Doesn't have any way to allow one user to see multiple sites no matter what binding they are connected to. For instance, if "jason" connects to ftp.domain.com, he should be able to see domain2.com, domain3.com without seeing domain4.com and domain5.com. It takes an act of God to set this up with IIS7. So I'm wanting to install a third party FTP server instead. I've looked at FileZilla both ZFTPServer. Anyone know of any pros/cons on these? Any other recommendations?

    Read the article

  • How can I remotely tell what brand/model internal SCSI card is installed in a machine?

    - by edmicman
    I am doing some consulting work for a previous employer upgrading and migrating old servers to new hardware. There is an existing file server (HP ProLiant DL380) that has an tape backup drive connected; it is using a SCSI interface and I'm pretty sure it's using an internal SCSI card. They are upgrading to a new server hardware (HP ProLiant DL160 G6). The old server is 2U, the new one 1U and we would want to move the tape drive to the new server, too. I'm trying to figure out if the SCSI card in the old server would be able to be installed in the new one or if we'll need to source a new card; mostly I don't know for sure the height of the card and if it's low-profile enough that it would fit in the new server. There is not much of a technical resource onsite and the old server is in-use anyway so I would like to avoid making a trip in myself or trying to have someone onsite pop open the case and tell me what card is there. It's running Windows Server 2003 - is there a way to tell from say Device Manager what make and model the SCSI card might be? Or any other system diagnostic program or something that would give me hardware info like that? Thanks for any info!

    Read the article

  • RemoteApp .rdp embed creds?

    - by Chris_K
    Windows 2008 R2 server running Remote Desktop Services (what we used to call Terminal Services back in the olden days). This server is the entry point into a hosted application -- you could call it Software as a Service I suppose. We have 3rd party clients connecting to use it. Using RemoteApp Manager to build RemoteApp .rdp shortcuts to distribute to client workstations. These workstations are not in the same domain as the RDS server. There is no trust relationship between domains (nor will there be). There is a tightly controlled site to site VPN between workstations and the RDS server, we're quite confident we have access to the server locked down. The remoteApp being run is an ERP application with its own authentication scheme. The issue? I'm trying to avoid the need to create AD logins for every end user when connecting to the RemoteApp server. In fact, since we're doing a remoteApp and they have to authenticate to that app, I'd rather just not prompt them at all for AD creds. I certainly don't want them caught up in managing AD passwords (and periodic expirations) for accounts they only use to get to their ERP login. However, I can't figure out how to embed AD creds in a RemoteApp .rdp file. I don't really want to turn off all authentication on the RDS server at that level. Any good options? My goal is to make this as seamless as possible for the end-users. Clarifying questions are welcome.

    Read the article

  • Which linux distributions offer seamless support for UEFI and an LVM root out of the box?

    - by Jannik Jochem
    My new ultrabook (an Asus UX32VD) requires UEFI in order to boot from the internal harddisk. I use an LVM partition which contains my root fs and dual-boot Windows 8. I somehow managed to get this working on Sabayon Linux, however the overall process was pretty painful, and system upgrades keep breaking my configuration because everything depends on a hand-configured kernel and a hand-crafted GRUB2 configuration. This causes a lot of hassle and distractions for me, so I am considering to switch to a different distribution. However, I cannot find any concrete resources that precisely document the state of UEFI support in the popular distributions. As an example, the length of the Ubuntu wiki page on UEFI suggests that installing on UEFI systems is a non-trivial process, and this AskUbuntu thread on encrypted LVM on UEFI systems suggests that LVM might also be a problem. I know that this question seems somewhat open-ended, so I'll formulate concrete questions: Are there any Linux distributions with an installer that supports installing to an LVM root in a UEFI boot setting where Windows 8 is dual-booted? Which distributions support UEFI without having to jump through hoops in order to bootstrap into a UEFI-booted system or requiring manual configuration of the boot manager?

    Read the article

  • scanner no longer working windows 7

    - by Sackling
    I have a windows 7 64 pro machine that for some reason no longer works with a brother all in one printer/scanner, when I try to scan. This happened seemingly out of nowhere. Printing still works. When I try to scan from photoshop, photoshop crashes. When I try to scan from device manager (which takes a really long time to access the printer) I get an error saying: "operation could not be completed. (error 0x00000015). the device is not ready. I tried uninstalling/reinstalling the printer and drivers. I have also run the brother driver cleaner and then reinstalled and get the same results every time. I had access to another HP all in one. And very strangely When I setup this new printer I have a similar issue that happens. I am able to print but when I try to scan from the HP tool nothing pops up. So my thoughts are it is something to do with the twain driver? But I don't know what to do or check. Any help is appreciated.

    Read the article

  • can not connect to SQL running on amazon ec2 machine

    - by njj56
    I am using SQL managment studio 2008 running on an Amazon EC2 machine. I am unable to connect to the database in my asp.net application. The EC2 instance has been set to accept connections over the SQL port. I am also able to remote the machine as well as view websites hosted on the server. Listed below is part of the connection string relating to this instance. When the program is ran and this connection string is called, it returns tcp error 0 - no return response. it just times out. <add name="ProjectServer" connectionString="Data Source=*IP ADDRESS HERE*,1433;Initial Catalog=*Catalog Name*;User ID=IP-0A6ED514\Administrator;"/> I removed the ip and the catalog name for the example, but I am sure they are correct. The only thing that I could think may cause an error, is the differences in names between the user id and the server name - the server name is ip-0A6ED514\sharepoint but the user name is ip-0A6ED514\administrator when I log into the sql server manager on the EC2 instance. A password is not used. Not sure if I would need to leave in a blank string for password - also not sure if the difference between server name and user id to log in makes a difference. Any help is appreciated. Thank you. update - when this connection string is used with out the port, i get tcp provider error 40 - when the port is in there, i get error 0 edit- the sql server is using windows authentication - does this make a difference? Usually I always use SQL server authentication

    Read the article

  • Live Mesh starts exactly once on fresh Win7 Ultimate installation

    - by Reb.Cabin
    I did a fresh install of Windows 7 Ulimate 64-bit on a formatted drive on a refurbed Lenovo PC, applied all 102 (!) windows updates, windows seems to be working fine. No quirks installing, no apps, no junkware, just straight, legal, Win7 Ultimate right from an unopened 2009 Microsoft box. Ok, breathe sigh -- Install Live Mesh (no messenger, no mail, no writer, no photo, none of the rest of the Windows Live freeware). Set up my shares, let it run overnight. watch MOE.exe in the Task-Manager perf pane to make sure it's all settled down. reboot. Ok, check that MOE is running and files are getting updated properly from other machines in the mesh. Great. HOWEVER -- when I try to launch Windows Live Mesh app from the Start jewel, I get a brief hourglass, then nothing. Reboot. Same story. result -- the shares I already posted seem to be synching properly, but I can't run the app, so I can't add and delete shares. The background process MOE seems to run, but I can't get the app going. btw, the reason I did this fresh install is I had exactly the same experience running Vista, so I wiped the machine hoping it would solve this nasty problem. Imagine my surprise! Will be grateful for clues, advice, etc, please & thanks!

    Read the article

  • How to prevent blocking http auth popups on firefox restart with many tabs open

    - by Glen S. Dalton
    I am using the latest firefox with tab mix plus and tabgoups manager. I have maybe 50 or 100 tabs oben in different tab groups. When I shutdown firefox and start it again all tabs and tab groups are perfectly rebuilt. But I have also many pages open that are behind a standard http auth, and these pages all request their usernames and passwords. So during startup firefox pops up all these pages' http auth windows. And they block everything else in firefox, they are like modal windows. (I am involved in website development and the beta versions are behind apache http auth.) I have to click many times the OK button in the popups, before I can do anything. All the usernames and passwords are already filled in. (And the firefox taskbar entry blinks and the firefox window heading also blinks, and focus switches back and foth, which also annoys me. And sometimes the popups do not react to my clicks, because firefox is maybe just switching focus somewhere else. This is the worst.) I want a plugin or some way to skip those popups. There are some plugins I tried some time ago, but they did not do what I need, because they require a mouse click for each login, which is no improvement over the situation like it already is. This is not about password storage (because firefox already stores them). But of course, if some password storing plugin could heal this it would be great.

    Read the article

  • Controller Error: Do I need to worry?

    - by Kryten
    Hi, I have a HP Pavillion dv5224ea Laptop with Windows 7 on it. Recently I discovered a Error in Event Viewer: The driver detected a controller error on \Device\Ide\IdePort1. (more details): - System - Provider [ Name] atapi - EventID 11 [ Qualifiers] 49156 Level 2 Task 0 Keywords 0x80000000000000 - TimeCreated [ SystemTime] 2010-03-07T12:43:07.090197600Z EventRecordID 30198 Channel System Computer Alistair-Win7 Security - EventData \Device\Ide\IdePort1 0000100001000000000000000B0004C002000000850100C00000000000000000000000000000000000000000000000000000000004100000 -------------------------------------------------------------------------------- Binary data: In Words 0000: 00100000 00000001 00000000 C004000B 0008: 00000002 C0000185 00000000 00000000 0010: 00000000 00000000 00000000 00000000 0018: 00000000 00001004 In Bytes 0000: 00 00 10 00 01 00 00 00 ........ 0008: 00 00 00 00 0B 00 04 C0 .......À 0010: 02 00 00 00 85 01 00 C0 ......À 0018: 00 00 00 00 00 00 00 00 ........ 0020: 00 00 00 00 00 00 00 00 ........ 0028: 00 00 00 00 00 00 00 00 ........ 0030: 00 00 00 00 04 10 00 00 ........ Event Viewer is recording A LOT of these errors (sometimes 13, one after the other!). Do I need to worry? What does this error mean? What device could "\Device\Ide\IdePort1" be? What is a ATAPI Error? Do I need to re-install Windows? I generally find the occurs when I try to backup my machine (using Windows Backup) or when using a program that uses Volume Shadow Copy. I have run "sfc", no problems. There are no Device Errors in Device Manager. I have also run "vssadmin list writers", no problems. Whats going on??? Would it be a good idea to re-install Windows 7?

    Read the article

  • I had a power outage. Now MySQL's lock file won't go away. What do you suggest?

    - by jasonspiro
    I do freelance IT consulting for various clients, both in Toronto, Canada, and worldwide. A client recently experienced a power failure. Now they've been having various problems with a Slackware 12.0.0 machine which also acts as a DNS server. One problem is that they can't log into phpMyAdmin. I tried stopping and restarting MySQL. But even when MySQL is stopped, the lock file stays around. jasonspiro@cybertron:~$ sudo /etc/init.d/mysql stop Shutting down MySQL. SUCCESS! jasonspiro@cybertron:~$ sudo /etc/init.d/mysql stop ERROR! MySQL manager or server PID file could not be found! jasonspiro@cybertron:~$ sudo /etc/init.d/mysql status ERROR! MySQL is not running, but lock exists jasonspiro@cybertron:~$ ls -l /var/lock/subsys/mysql -rw-r--r-- 1 root root 0 2012-07-05 16:18 /var/lock/subsys/mysql Why is MySQL's lock file hanging around despite the fact that MySQL isn't running? Can I simply stop MySQL, delete the lock file, and start MySQL again? Are there any other steps that I should take next, or nothing?

    Read the article

  • Connect over WiFi to SQL Server from another computer

    - by Bronzato
    I tried to connect over WiFi to SQL Server with SQL Server Management Studio from another computer, but it failed. I have a computer with Windows 7 & SQL Server 2008 (lets say the server computer). Next to it I have a freshly installed computer with Windows 7 & SQL Server Management Studio (let's say the client computer). What I did on the server computer: Configure firewall by enabling port 1433 Enabled network protocols (TCP/IP) inside SQL Server Configuration Manager Checked Allow remote connections to this server in server properties in the SQL Server Management application. Started SQL Server Browser Restarted services (SQL Server Browser is stopped at this point, but I don't think it is necessary. Is it?) Next, I successfully tested a ping on the port 1433 from my client computer with a tool named tcping (ex: tcping 192.168.1.4 1433). But I still cannot connect from my client computer to SQL Server on my server computer. Ok, something new with this problem: Until now, I successfully connected to my "server computer" with Management Studio. What I did is type the computer name in the server name field in the connection window of Management Studio. My previous (failed) attempt was to type the computer name followed by the instance of SQL server (ex: COMPUTER_NAME\SQL2008). I don't know why I only have to type the computer name. Now my new challenge is to be successful in connecting my VB6 application to this remote database located on my "server computer". I have a connection string for this but it failed to connect. Here is my connection string: "Provider=SQLOLEDB.1;Password=mypassword;User ID=sa;Initial Catalog=TPB;Data Source=THIERRY-HP\SQL2008" Any idea what's going wrong?

    Read the article

  • Help Installing SQL Server 2008 Express Edition

    - by Jordan S
    Ok I am running Windows 7, 64 bit. I cleaned of SQL server 2005 completely off my system leaving only SQL Compact Edition. I went here http://www.microsoft.com/downloads/details.aspx?FamilyID=01af61e6-2f63-4291-bcad-fd500f6027ff&displaylang=en and installed SQL Server 2008 Express Edition Service Pack 1. After the install, under my start bar menu all i have for SQL configuration tools are the Configuration Manager, Error and Usage Reporting and the Install Center. I don't have the SQL Managment Studio. So I went here http://www.microsoft.com/downloads/details.aspx?FamilyID=08e52ac2-1d62-45f6-9a4a-4b76a8564a2b&displaylang=en and downloaded the SQL Server 2008 Management Studio Express but when I try to install it I get a warning says This program has known compatibility issues and that I need to Install SQL Server 2008 Service Pack 1. I thought that is what I installed. So, I tried to continue running the install but I then get an error message that says Invoke or BeginInvoke can not be called on a Form before it is opened... How can I check if Service pack 1 is installed or not? What should I do? Also I rebooted my system and checked for Windows Updates and it says that Windows it up to date.

    Read the article

  • CD-ROM Cant Be Accessed After Installing VMware Tools on VMware Server 2.0.2

    - by Optimal Solutions
    Using VMware Server 2.02, I set up a new VM (Windows XP Pro) applied all of the updates, added Windows addons from the install CD, etc... I got it to a stable point and up through that point I was able to access the CD-ROM drive (E: on my host). What I never did before was install "VMware Tools" and since it claims to give better mouse and video support, I gave it a shot. What it does is it places the install package in a virtual CD-ROM drive. I ran the install, no errors and it wants a reboot. I log back in after reboot and pop in the install CD for Microsoft Office 2003 and I receive the message "Please Insert A Disc Into Drive D:". Drive D: would be the next logical drive after the C: drive where I chose to install the OS. The message box sits there and if I click "Cancel", to return to Windows Explorer, the status bar seems to blink ever 1/2 second - as if its polling for a CD-ROM drive or something. No bangs or exclamations in the Device Manager for any hardware. I had taken a snapshot prior to the VMware Tools install and upon restoring it, the CD-ROM is back. I made copies of two other VMs, installed the VMware Tools on those VMs and both experienced the same issues: Windows 2003 Server and Windows 7 (32-bit). Has anyone seen this issue and know of a fix for this? It would be nice to have the better graphics and better mouse control AND use my CD-ROM drive as well! Thank you.

    Read the article

  • Webcam becomes "Unknown Device" after Windows Messenger 2011 is installed

    - by Boris
    I have Sony VAIO VGN-NS290J laptop. I installed Windows 7 Ultimate 64-bit. I was able to find drivers for all hardware without any problems. Recently, I installed Microsoft Windows Live Essentials 2011, i.e. Windows Live Messenger 2011. Ever since that application is running on my computer, my webcam is not recognized by the OS any more. It is listed as the "Unknown Device" and placed in the Universal Serial Bus controllers group in the Device Manager. There don't seem to be any drivers for this webcam. It's a standard Sony Motion Eye web camera and Sony does not offer any drivers for it. There is one application to download that utilizes the camera, but there are no drivers (and the system is showing the same behavior regardless of the presence of the application). It happens from time to time that the webcam becomes recognized by the OS again, after a couple of restarts; but not always. Then it becomes unknown again. I am absolutely positive that this issue is caused by the Windows Live Messenger 2011, because same symptoms caused the same effects before. I wish to be able to continue to use this software, but also to use my webcam. I was wondering if anyone had a similar issue and if there is a way to fix it. Thanks for all the help, I appreciate it. Update: I have discovered a pattern - if the camera goes astray, restarting the machine does not bring it back; but switching the computer off and turning it back on does. Every time! This is getting super complicated :)

    Read the article

  • Windows Server 2008 R2 install reboots unexpectedly during "Completing installation" phase

    - by knda
    I am attempting to install Windows Server 2008 R2 onto a Cisco UCS C201 M2 rack mounted server but am having major difficulties and wondering if anyone has some insight or items they could recommend for me to look at to get this one resolved. Installation is being attempted via the Cisco remote console (using CIMC's Virtual dvd-rom).. following the first phase of Setup where the installation files are copied to the target hard drive, then a reboot occurs to load Setup from the HDD, mid-way in the "Completing Installation" phase the system then reboots unexpectedly. System configuration Cisco UCS C201 M2 (2RU rack mounted server) 16GB RAM, 2x 73GB 15K SAS, 4x 300GB 10k SAS Add-on cards - Intel quad-port GigE card (no fibre channel cards) Storage - LSI MegaRAID SAS 9261-8i. onboard SATA is disabled (no SATA drives connected) KVM - Belkin No physical DVD-ROM.. :( I have... Run memtest86+, no RAM faults Disabled/enabled SATA support (BIOS) Attempted install from USB DVD-ROM, no effect Attempted unattended install scripted via Cisco Configuration Manager DVD provided Removed Belkin KVM in case that was causing drama Discovered that the Cisco website is "awesome" for searching for PDFs/Drivers cough, reverted back to Google Downloaded latest LSI drivers from LSI's site and used during Server 2008 install checked Windows ISO against checksum's from MS site checked Windows ISO by using it for an install in a VM Running out of ways to troubleshoot this as I am not sure how to enable any sort of 'verbose' mode during the setup process. Next step I have planned is to remove the Intel NIC and try the installation again.. Edit: Problem was the "Cisco INTEL QUAD PT GBE" (1000/PT) .. will have to see if this card is faulty or if it's just drivers.. thanks for the help.

    Read the article

  • Linux Sound Drivers - Recompiling kernel with ehcd-hcd module

    - by jhome
    I just installed Linux Mint and I am trying to get my usb soundcard to work. I am completely new to Linux so I have only been learning about all the important parts of the OS this afternoon. No one I know has compiled kernel so I can't ask anyone. I am following instructions on this site: http://wiki.ubuntuusers.de/Benutzer/BigMc#Final-setup-of-US-122L-US-144 "Recompile your Kernel with ehcd-hcd as a module: Instructions for Ubuntu (german) Change "Device Drivers - USB support - EHCI HCD (USB 2.0) support)" to "M" when configuring. Make sure you also install the kernel headers." I know how to do any of these processes. Someone mentioned a package manager. Is recompiling basically in layman's terms reinstallation? Where do I go to the change device drivers? Cheers Edit: I am attempting to be able to use my Tascam US-144 on Linux Mint. Apparently, to use it properly it has to regress to functionality of a former unit (US-122), so according to the instructions a USB port has to be USB 1.0, rather than USB 2.0. I've tried using that ndis** programme for wireless drivers but with no success.

    Read the article

  • Xvnc4 started from xinetd only displays empty gray X screen

    - by Scott Thomason
    I'm attempting to setup an Ubuntu 10.10 box so that anyone can connect to port 5900 and be greeted by the gdm login manager. To do so, I added a vnc entry in /etc/services and I am starting Xvnc4 using this xinetd config file: service vnc { protocol = tcp socket_type = stream wait = no user = nobody server = /usr/bin/Xvnc server_args = -geometry 1000x700 -depth 24 -broadcast -inetd -once -securitytypes None } This kind of works...I can start multiple sessions all to port 5900, and I get an X screen. The problem is that I only get an empty, gray X screen with no applications started. I know when you run vncserver from the command line it will look to your ~/.vnc/ directory for your passwd and xstartup files, and I think what I want to do is put "gnome-session" into the xstart file. However, which xstartup file? The running user is "nobody" who obviously doesn't have a ~/.vnc/ directory. I tried a /root/.vnc/xstartup file and a ~scott/.vnc/xstartup file and it doesn't look like they were even read. I changed the xinetd vnc service so that it would "strace" Xvnc4. I looked thru all the "open" lines and didn't get a clue as to what file it was trying to read for xstart. Can anyone help? I just want a terminal server where the user is presented with a gdm login screen.

    Read the article

< Previous Page | 508 509 510 511 512 513 514 515 516 517 518 519  | Next Page >