  • Dell OMCI: Wacky values for Temperature and etc? (Win7x64)

    - by Yablargo
    Hey All. I am running a Dell Precision R5400 Workstation with dell OMCI installed. I am using it to test polling various data over WMI for our monitoring across the enterprise. I'm getting some weird results. perhaps someone can help point me in the direction of some clarification? Posted is the results of my DCIM\SYSMAN\DCIM_NumericSensor probe for sensor type 2(temp sensor) Microsoft (R) Windows Script Host Version 5.8 Copyright (C) Microsoft Corporation. All rights reserved. ----------------------------------- DCIM_NumericSensor instance ----------------------------------- Accuracy: AccuracyUnits: AdditionalAvailability: Availability: AvailableRequestedStates: BaseUnits: 2 Caption: CommunicationStatus: CreationClassName: DCIM_NumericSensor CurrentReading: -214748365 CurrentState: Unknown Description: DetailedStatus: DeviceID: Root/MainSystemChassis/TemperatureObj ElementName: Temperature Sensor:CPU0 EnabledDefault: 2 EnabledState: 2 EnabledThresholds: ErrorCleared: ErrorDescription: HealthState: 5 Hysteresis: IdentifyingDescriptions: InstallDate: IsLinear: LastErrorCode: LocationIndicator: LowerThresholdCritical: LowerThresholdFatal: LowerThresholdNonCritical: MaxQuiesceTime: MaxReadable: MinReadable: Name: NominalReading: NormalMax: NormalMin: OperatingStatus: OperationalStatus: 2 OtherEnabledState: OtherIdentifyingInfo: OtherSensorTypeDescription: PollingInterval: PossibleStates: Unknown,Normal,Fatal,Lower Non-Critical,Upper Non-Critical,Lower Critical,Upper Critical PowerManagementCapabilities: PowerManagementSupported: PowerOnHours: PrimaryStatus: ProgrammaticAccuracy: RateUnits: 0 RequestedState: 12 Resolution: SensorType: 2 SettableThresholds: Status: StatusDescriptions: StatusInfo: SupportedThresholds: SystemCreationClassName: DCIM_ComputerSystem SystemName: dt:5Q7BKK1 TimeOfLastStateChange: Tolerance: TotalPowerOnHours: TransitioningToState: 12 UnitModifier: 0 UpperThresholdCritical: UpperThresholdFatal: UpperThresholdNonCritical: ValueFormulation: 2 I'm not really sure whats going on, but note the CurrentReading: -214748365. I have reinstalled OMCI a few times, installed the OMCI 7x compatability and same thing I consistently get that error. It almost looks like its a issue between 32/64 bit value or something? Do I have to convert it to a float ? :)

    Read the article

  • C Programming arrays, I dont understand how I would go about making this program, If anyone can just guide me through the basic outline please :) [on hold]

    - by Rashmi Kohli
    Problem The temperature of a car engine has been measured, from real-world experiments, as shown in the table and graph below: Time (min) Temperature (oC) 0 20 1 36 2 61 3 68 4 77 5 110 Use linear regression to find the engine’s temperature at 1.5 minutes, 4.3 minutes, and any other time specified by the user. Background In engineering, many times we measure several data points in an experiment, but then we need to predict a value that we have not measured which lies between two measured values, such as the problem statement above. If the relation between the measured parameters seems to be roughly linear, then we can use linear regression to find the relationship between those parameters. In the graph of the problem statement above, the relation seems to be roughly linear. Hence, we can apply linear regression to the above problem. Assuming y {y0, y1, …yn-1} has a linear relation with x {x0, x1, … xn-1}, we can say that: y = mx+b where m and b can be found with linear regression as follows: For the problem in this lab, using linear regression gives us the following line (in blue) compared to the measured curve (in red). As you can see, there is usually a difference between the measured values and the estimated (predicted) values. What linear regression does is to minimize those differences and still give us a straight line (blue). Other methods, such as non-linear regression, are also possible to achieve higher accuracy and better curve fitting. Requirements Your program should first print the table of the temperatures similar to the way it’s printed in the problem statement. It should then calculate the temperature at minute 1.5 and 4.3 and show the answers to the user. Next, it should prompt the user to enter a time in minutes (or -1 to quit), and after reading the user’s specified time it should give the value of the engine’s temperature at that time. It should then go back to the prompt. Hints •Use a one dimensional array to store the temperature values given in the problem statement. •Use functions to separate tasks such as calculating m, calculating b, calculating the temperature at a given time, printing the prompt, etc. You can then give your algorithm as well as you pseudo code per function, as opposed to one large algorithm diagram or one large sequence of pseudo code.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Graphing perpendicular offsets in a least squares regression plot in R

    - by D W
    I'm interested in making a plot with a least squares regression line and line segments connecting the datapoints to the regression line as illustrated here in the graphic called perpendicular offsets: http://mathworld.wolfram.com/LeastSquaresFitting.html I have the plot and regression line done here: ## Dataset from http://www.apsnet.org/education/advancedplantpath/topics/RModules/doc1/04_Linear_regression.html ## Disease severity as a function of temperature # Response variable, disease severity diseasesev<-c(1.9,3.1,3.3,4.8,5.3,6.1,6.4,7.6,9.8,12.4) # Predictor variable, (Centigrade) temperature<-c(2,1,5,5,20,20,23,10,30,25) ## Fit a linear model for the data and summarize the output from function lm() severity.lm <- lm(diseasesev~temperature,data=severity) # Take a look at the data plot( diseasesev~temperature, data=severity, xlab="Temperature", ylab="% Disease Severity", pch=16 ) abline(severity.lm,lty=1) title(main="Graph of % Disease Severity vs Temperature") Should I use some kind of for loop and segments http://www.iiap.res.in/astrostat/School07/R/html/graphics/html/segments.html to do the perpendicular offsets? Is there a more efficient way? Please provide an example if possible.

    Read the article

  • SSD becomes hot, disk failure warning

    - by Aegluin
    I have a two weeks old SSD (Kingston SSDnow 64GB). Yesterday, the computer shutdown twice and after rebooting I was bombarded with disk failure warnings. I usually take such warnings serious (and backed up), but skeptical. After cooling down, the laptop boots again and the only red Smart value was the temperature (Ubuntu did not show the temperature of failure, but the at that time 29°). After refreshing the Smart status and doing a "self test", everything is green. Before contacting Kingston support, I would like to know whether it could be due to a software issue: Is it possible that it is false alarm, and how can I check? I installed Ubuntu 12.04 32bit and took care of alignment. I supposed Ubuntu set up with optimal settings for SSDs, how can I check that there was no mistake? The current temperature is around 40-56°. Is such a temperature abnormal for SSDs? Output of sudo smartctl --all /dev/sda: http://pastebin.ubuntu.com/1175940/

    Read the article

  • CPU overheating after cleaning it

    - by Roberts
    I wanted to clean my computer CPU heatsink and fan itself, because the temperature is not what I wanted. About (50C ~ 70C). I have Intel Core 2 Duo E4300 @1.8 GHz (LGA775). The heatsink wasn't so scary filled with dust but I wanted to clean it anyway. I didn't know how to get heatsink with fan from the socket. So after 25 minutes I've figured it out. But I didn't know how to get it back on so I spent a lot time getting out the motherboard from the case. The fan and heatsink... The case and all components are clear of dust. (I'm tired now). Then I put all back just the way it was, well did few things on cable management. But the problem was that I didn't know how to connect front audio connectors. I had Windows XP hibernated. So I started the PC and everything was normal, except CMOS memory was clear. I configured the BIOS just the way it was and while I was doing that I saw about 58C CPU temperature and fan at 1789 RPM. Restarted the computer with new settings applied. But Windows halted with Blue Screen (I forgot what error it was but something with KERNEL). Restarted the PC and deleted hibernation session and everything was back normal. But couldn't record any sound from front panel microphone. The problem was that I messed ground wire with mic. Again after fixing it I turned computer on. No problems. The fan currently is noisy and temperature was 78C. The temperature before was 55C - 60C at idle. Now it's about 60C. If I do something then temperature raises to 79C. While speaking in skype the temperature was 82C. Could this problem occur because of the thermal grease (it's old and never replaced)? Edit The problem wasn't in thermal paste (because I didn't touch it). The problem was that I installed heatsink wrong. Now instead of regular 60C CPU temperature the CPU is at 48C (cool).

    Read the article

  • Is my disk hot or not?

    - by adriangrigore
    I am trying to figure out the temperature of my dedicated server's harddisk. For this purpose, I've downloaded HDTune to monitor the S.M.A.R.T. Status. The problem is that the current temperature for "C2 Temperature" is 73 degrees celsius, but the little thermometer on top of the window shows 27 degrees celsius. See this screenshot: http://screencast.com/t/OGJhZGIxND Another monitoring software (Anfibia Reactor) shows similar behavior: Disk temperature is around 30 degrees, but it says that the disk is too hot. So, is my disk hot or not? Since this is a dedicated server, I can't just open the case and put a thumb on it.

    Read the article

  • SteelSeries & JavaFX External Control via Tinkerforge

    - by Geertjan
    The first photo shows me controling a JavaFX chart by rotating a Tinkerforge device, while the other two are of me using code by Christian Pohl from Nordhorn, Germany, to show components from Gerrit Grunwald's SteelSeries library being externally controled by Tinkerforge devices: What these examples show is that you can have a robot (i.e., an external device), of some kind, that can produce output that can be visualized via JavaFX charts and SteelSeries components. For example, imagine a robot that moves around while collecting data on the current temperature throughout a building. That's possible because a temperature device is part of Tinkerforge, just like the rotating device and distance device shown in the photos above. The temperature data collected by the robot would be displayed in various ways on a computer via, for example, JavaFX charts and SteelSeries components. From there, reports could be produced and adjustments could be made to the robot while it continues moving around collecting temperature data. The fact that Tinkerforge has Wifi support makes a scenario such as described here completely possible to implement. And all of this can be programmed in Java, without very much work, since the Java bindings for Tinkerforge are simple to use, such as shown in yesterday's blog entry.

    Read the article

  • Internet of Things (IoT) Thanksgiving Special: Turkey Tweeter (Part 1)

    - by hinkmond
    It's time for the Internet of Things (ioT) Thanksgiving Special. This time we are going to work on a special Do-It-Yourself project to create an Internet of Things temperature probe to connect your Turkey Day turkey to the Internet by writing a Thanksgiving Day Java Embedded app for your Raspberry Pi which will send out tweets as it cooks in your oven. If you're vegetarian, don't worry, you can follow along and just run the simulation of the Turkey Tweeter, or better yet, try a tofu version of the Turkey Tweeter. Here is the parts list: 1 Vernier Go!Temp USB Temperature Probe 1 Uncooked Turkey 1 Raspberry Pi (not Pumpkin Pie) 1 Roll thermal reflective tape You can buy the Vernier Go!Temp USB Temperature Probe for $39 from here: http://www.vernier.com/products/sensors/temperature-sensors/go-temp/. And, you can get the thermal reflective tape from any auto parts store. (Don't tell them what you need it for. Say it's for rebuilding your V-8 engine in your Dodge Hemi. Avoids the need for a long explanation and sounds cooler...) The uncooked turkey can be found in your neighborhood grocery store. But, if you're making a vegetarian Tofurkey, you're on your own... The Java Embedded app will be the same, though (Java is vegan). So, grab all your parts and come back here for the next part of this project... Hinkmond

    Read the article

  • The plugin of munin is always timed out

    - by haoX
    I want to use munin to make a graph of ttyACM0 in Linux, but munin can not create the graph. I found some information in "munin-node.log". it shows that "Service 'temperature' timed out". So I changed timeout to 60 or 120 in /munin/plugin-conf.d/munin-node, but it does not work. It's also timed out. Here is part of my code: if [ "$1" = "config" ]; then echo 'graph_title Temperature of board' echo 'graph_args --base 1000 -l 0' echo 'graph_vlabel temperature(°C)' echo 'graph_category temperature' echo 'graph_scale no' echo 'graph_info This graph shows the temperature of board' for i in 1 2 3 4 5; do case $i in 1) TYPE="Under PCB" ;; 2) TYPE="HDD" ;; 3) TYPE="PHY" ;; 4) TYPE="CPU" ;; 5) TYPE="Ambience" ;; esac name=$(clean_name $TYPE) if [ "$TYPE" != "NA" ]; then echo "temp_$name.label $TYPE"; fi done exit 0 fi for i in 1 2 3 4 5; do case $i in 1) TYPE="Under PCB" VALUE=$(head -1 /dev/ttyACM0 | awk '{print $1}') ;; 2) TYPE="HDD" VALUE=$(head -1 /dev/ttyACM0 | awk '{print $2}') ;; 3) TYPE="PHY" VALUE=$(head -1 /dev/ttyACM0 | awk '{print $3}') ;; 4) TYPE="CPU" VALUE=$(head -1 /dev/ttyACM0 | awk '{print $4}') ;; 5) TYPE="Ambience" VALUE=$(head -1 /dev/ttyACM0 | awk '{print $5}') ;; esac name=$(clean_name $TYPE) if [ "$TYPE" != "NA" ]; then echo "temp_$name.value $VALUE" fi

    Read the article

  • US Summer Heat Wave Visualized

    - by Jason Fitzpatrick
    While it seems like every summer people complain about the heat, this summer there’s a basis to their grievance. In the past month there have been 4,230 daily high-temperature records set across the continental United States. Over at NPR they’ve rounded up some environmental data that paints a picture of the US as a scorching hot place to be right now. The above map shows the number of locations reporting a recording setting temperature in the month of June; many of those places are on track to appear on the July map (available in the full NPR post). For more interesting stats about this year’s heatwave–like the fact that record temperature reports are up 71% from last year–hit up the link below. How Hot Is It? All You Need To See Are These Two Maps [NPR] How to Use an Xbox 360 Controller On Your Windows PC Download the Official How-To Geek Trivia App for Windows 8 How to Banish Duplicate Photos with VisiPic

    Read the article

  • Samsung Series 5 overheating

    - by Sean Brad
    I bought a Samsung Series 5 Ultra 2 weeks ago and installed Ubuntu 12.04 LTS. I am experiencing problems with overheating. When streaming, watching a movie or when having several programms/actions going on at the same time the CPU temperature rises to 95 degrees and the computer freezes. This happens sometimes when the computer is on battery and always when it is recharging. When I am using the computer on battery the CPU temperature is floating from around 75-95 degrees depending what it's doing. When the battery is recharging the CPU temperature is ranging from 88-95 degrees no matter what tasks it performs. Have anyone experienced this and how may the problem be solved? Best regards

    Read the article

  • HP 4510s Probook Overheating

    - by Ivan
    I am having overheating problems with Ubuntu 12.04. Average temperature is approximately 70-74 °C and when Skype is turned on it goes nuts over 80 °C. Elipse refuses to open for some reason and of course everything is slower than it should be. I also had Linux Mint 11 installed and same thing happened. Strange thing is when running Windows, everything is okay and temperature is normal. Of course I have googled this issue and found some advices like install Jupiter which helped just a bit, installed additional drivers, opened laptop and cleaned it completely, disabled fan always on option from Bios. I have also switched from Unity to classic old look and still temperature is the same. Somehow I think it has something to do with the graphics card but I am all lost now. Any advices? Thank you!

    Read the article

  • How to use SQL to output latest info with multiple col

    - by TGU
    Hi, I have a "weather" table below with 3 cols: City Temperature Date New York 22 C 10/10/2005 Seattle 21 C 10/10/2005 New York 18 C 10/09/2005 Seattle 20 C 10/09/2005 Washington 17 C 10/09/2005 New York 21 C 10/08/2005 Washington 20 C 10/08/2005 I want to find out the latest info on the City and Temperature in 3 cols as well (see example): City Temperature Date New York 22 C 10/10/2005 Seattle 21 C 10/10/2005 Washington 17 C 10/09/2005 Can anyone help? Thanks Rgds

    Read the article

  • ViewPager and Fragment Pager adapter implementation

    - by Rohit Deshmukh
    So I am trying to implement sliding views/fragments using viewpager and fragment pager adapter. convert_home is my main xml file that has android.support.v4.view.PagerTitleStrip and temperature.xml and velocity.xml are my two other views. I have no clue where I am going wrong. package app.converto; import android.os.Bundle; import android.support.v4.app.Fragment; import android.support.v4.app.FragmentActivity; import android.support.v4.app.FragmentManager; import android.support.v4.app.FragmentPagerAdapter; import android.support.v4.view.ViewPager; import android.view.LayoutInflater; import android.view.Menu; import android.view.View; import android.view.ViewGroup; import android.widget.TextView; public class ConverTo extends FragmentActivity { SectionsPagerAdapter mSectionsPagerAdapter; ViewPager mViewPager; @Override public void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); mSectionsPagerAdapter = new SectionsPagerAdapter(getSupportFragmentManager()); mViewPager.setAdapter(mSectionsPagerAdapter); setContentView(R.layout.converto_home); mViewPager = (ViewPager) findViewById(R.id.pager); } @Override public boolean onCreateOptionsMenu(Menu menu) { getMenuInflater().inflate(R.menu.converto_home, menu); return true; } public class SectionsPagerAdapter extends FragmentPagerAdapter { public SectionsPagerAdapter(FragmentManager fm) { super(fm); } @Override public Fragment getItem(int i) { switch(i){ case 0: Fragment1 fragment = new Fragment1(); return fragment; case 1: Fragment2 fragment2 = new Fragment2(); return fragment2; } defaultFragment fragment3 = new defaultFragment(); return fragment3; } @Override public int getCount() { return 2; } // // @Override // public CharSequence getPageTitle(int position) { // switch (position) { // case 0: return getString(R.string.velocity); // case 1: return getString(R.string.temperature); // case 2: return getString(R.string.distance); // } // return null; // } } public static class Fragment1 extends Fragment{ public Fragment1(){ } @Override public void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); } @Override public View onCreateView(LayoutInflater inflater, ViewGroup container, Bundle savedInstanceState) { //return inflater.inflate(R.layout.temperature, container, false); View view = inflater.inflate(R.layout.temperature, container, false); TextView textView = (TextView) view.findViewById(R.id.sample); textView.setText(getArguments().getString("title")); return view; } } public static class Fragment2 extends Fragment{ public Fragment2(){ } @Override public void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); } @Override public View onCreateView(LayoutInflater inflater, ViewGroup container, Bundle savedInstanceState) { //return inflater.inflate(R.layout.velocity, container, false); View view = inflater.inflate(R.layout.temperature, container, false); TextView textView = (TextView) view.findViewById(R.id.sample); textView.setText(getArguments().getString("title")); return view; } } public static class defaultFragment extends Fragment{ public defaultFragment(){ }//end constructor @Override public void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); } @Override public View onCreateView(LayoutInflater inflater, ViewGroup container, Bundle savedInstanceState) { // return inflater.inflate(R.layout.temperature, container, false); View view = inflater.inflate(R.layout.temperature, container, false); TextView textView = (TextView) view.findViewById(R.id.sample); textView.setText(getArguments().getString("title")); return view; }//end oncreate }//end default fragment }

    Read the article

  • Declaring arrays in c language without initial size

    - by user2534857
    this is the question-- Write a program to manipulate the temperature details as given below. - Input the number of days to be calculated. – Main function - Input temperature in Celsius – input function - Convert the temperature from Celsius to Fahrenheit.- Separate function - find the average temperature in Fahrenheit. how can I make this program without initial size of array ?? #include<stdio.h> #include<conio.h> void input(int); int temp[10]; int d; void main() { int x=0; float avg=0,t=0; printf("\nHow many days : "); scanf("%d",&d); input(d); conv(); for(x=0;x<d;x++) { t=t+temp[x]; } avg=t/d; printf("Avarage is %f",avg); getch(); } void input(int d) { int x=0; for(x=0;x<d;x++) { printf("Input temperature in Celsius for #%d day",x+1); scanf("%d",&temp[x]); } } void conv() { int x=0; for(x=0;x<d;x++) { temp[x]=1.8*temp[x]+32; } }

    Read the article

  • Does a hard drive "working hard", i.e. when defragmenting or otherwise continuously active, significantly affect a laptop's temperature?

    - by Marko
    Trying to diagnose and fix an overheating Acer 5735 laptop, running speedfan and doing general workload to try and cause the overheat conditions. I notice that windows xp is badly fragmented according to defraggler, at 58% fragmentation. So I defrag whilst watching the speedfan window, which was at the start reporting high warning style symbols for all of the sensors. After the defrag, I rebooted and ran a few programs, and even defraggler again and the sensors in speedfan all reported green i.e. not high. Wondering if there is a correlation between windows fragmentation causing the hard drive to work harder and produce more heat inside the laptop? dont want to just assume that the problems are resolved, so either speedfan is not accurate enough or fragmentation can lead to additional hard drive heat? All comments or suggestions welcome.

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • Fans running very fast on MacBook Pro 8.1 ubuntu 12.04

    - by Tomasz Kacprzak
    I installed Ubuntu 12.04 on Macbook Pro 8.1 and one of the first things I noticed was that the fans were starting to spin very fast every few minutes for 10-30 sec and then going back to normal. That was happening even without any processor load, when completely idle. The fans were usually spinning at 4000 RPM and made much noise. The computer was not getting hotter than usual. When running OSX Lion there was no noise at all, fans almost all the time at 2000 RPM. I spent some time on it and found out that Precise uses a deamon to control the temperature, called macfanctld. You can use /etc/macfanctld.conf to set the configuration. I found out that the high fan speed is not due to the fact that the temperature is getting hot, but because there are two sensors which indicate wrong numbers (you can check that using 'sensors' command ): TW0P: +129.0°C TCTD: +256.0°C TCFC: +0.0°C TMBS: +0.0°C or setting the macfanctld log level to 2: Speed: 4992, *AVG: 56.9C, TC0P: 50.2C, TG0P: 51.5C, Sensors: TB0T:34 TB1T:34 TB2T:33 TC0C:58 TC0D:56 TC0E:59 TC0F:60 TC0P:50 TC1C:58 TC2C:58 TC3C:58 TC4C:57 TCFC:0 TCGC:57 TCSA:53 TCTD:256 TG0D:52 TG0P:52 THSP:42 TM0S:64 TMBS:0 TP0P:54 TPCD:60 TW0P:129 Th1H:51 Th2H:48 Tm0P:40 Ts0P:32 Ts0S:43 Moreover, TCTD was randomly jumping from temperatures of 0 to 256, so this may be the reason for unjustified random fan speeds. macfanctld is taking an average of the sensors including the values above, so the actual AVG temp used to control the fans is wrong, usually biased up, hence high RPM and noise. The workaround solution is to use an option in the macfanctld.conf which allows to ignore the malfunctioning sensors: exclude: 13 16 21 24 After reboot the reported temperatures are usually normal and the fans are working at reasonable speeds. I tested the response of the fans to heavy processor load by asking MATLAB to invert 10000x10000 matrix and the AVG temperature jumped to 63deg, and the fan to max 6200 RPM and then got it back to normal temperature. So I think it is safe so far. There is a expired bug about the failing sensor readings: https://bugs.launchpad.net/ubuntu/+source/linux/+bug/955538 which may be good to open again. My question would be: does anyone know what the failing sensors do and if there is any danger in excluding them? Maybe some better solution to this problem?

    Read the article

  • Fans running very fast on MacBook Pro 8.1

    - by Tomasz Kacprzak
    I installed Ubuntu 12.04 on Macbook Pro 8.1 and one of the first things I noticed was that the fans were starting to spin very fast every few minutes for 10-30 sec and then going back to normal. That was happening even without any processor load, when completely idle. The fans were usually spinning at 4000 RPM and made much noise. The computer was not getting hotter than usual. When running OSX Lion there was no noise at all, fans almost all the time at 2000 RPM. I spent some time on it and found out that Precise uses a deamon to control the temperature, called macfanctld. You can use /etc/macfanctld.conf to set the configuration. I found out that the high fan speed is not due to the fact that the temperature is getting hot, but because there are two sensors which indicate wrong numbers (you can check that using 'sensors' command ): TW0P: +129.0°C TCTD: +256.0°C TCFC: +0.0°C TMBS: +0.0°C or setting the macfanctld log level to 2: Speed: 4992, *AVG: 56.9C, TC0P: 50.2C, TG0P: 51.5C, Sensors: TB0T:34 TB1T:34 TB2T:33 TC0C:58 TC0D:56 TC0E:59 TC0F:60 TC0P:50 TC1C:58 TC2C:58 TC3C:58 TC4C:57 TCFC:0 TCGC:57 TCSA:53 TCTD:256 TG0D:52 TG0P:52 THSP:42 TM0S:64 TMBS:0 TP0P:54 TPCD:60 TW0P:129 Th1H:51 Th2H:48 Tm0P:40 Ts0P:32 Ts0S:43 Moreover, TCTD was randomly jumping from temperatures of 0 to 256, so this may be the reason for unjustified random fan speeds. macfanctld is taking an average of the sensors including the values above, so the actual AVG temp used to control the fans is wrong, usually biased up, hence high RPM and noise. The workaround solution is to use an option in the macfanctld.conf which allows to ignore the malfunctioning sensors: exclude: 13 16 21 24 After reboot the reported temperatures are usually normal and the fans are working at reasonable speeds. I tested the response of the fans to heavy processor load by asking MATLAB to invert 10000x10000 matrix and the AVG temperature jumped to 63deg, and the fan to max 6200 RPM and then got it back to normal temperature. So I think it is safe so far. There is a expired bug about the failing sensor readings: https://bugs.launchpad.net/ubuntu/+source/linux/+bug/955538 which may be good to open again. My question would be: does anyone know what the failing sensors do and if there is any danger in excluding them? Maybe some better solution to this problem?

    Read the article

  • How to write a real time data acquisition program [closed]

    - by Tosin Awe
    I have to write a program in assembly language that will monitor temperature continuously, and I have no idea where to begin. The temperature must be displayed in BCD format, and the high and low set points will be programmed into the system. if the set points are exceeded then an alarm will be indicated. The low point is 20 degrees Celsius, and the high point is 24 degrees Celsius. Can somebody give me some hints on how to complete this task?

    Read the article

  • Max. Temp. on Intel Burn Test for Stock Dell Precision T3500

    - by HK1
    I'm troubleshooting an issue on a Dell Precision T3500. As part of my troubleshooting I've decided to try running a stress test using Intel Burn Test software. This machine is a stock configuration with 12GB of RAM and a Xeon W3670 processor (nothing overclocked). When I run IBT using the standard mode, SpeedFan reports a processor temperature in excess of 80C. I've seen numbers as high as 90C but even at that temperature the machine does not become unstable or crash. However, it seems way too high. This processor has a TCase of 67.9C according to Intel's website. I'm guessing that means I'm in the danger zone any time I go over that temperature. I've checked the cooling system and everything looks fine. I've even took out the heat sink and reinstalled it with new thermal compound. This did not appear to make the problem better or worse. Is there a discrepancy somewhere here in the way temperatures are measured or displayed? I've also tried using HWMonitor from CPUID and it reports the same temperatures. Should I just let the Standard Test go and disregard the temperature outputs?

    Read the article

  • Is there any way to use the xscreensaver gltext to monitor system information?

    - by Shane
    I am trying to get the X screensaver gltext to monitor my system temp and maybe some other stats. Writing a script that puts together the stats periodically is no problem, but the main thing I'm running into is that gltext doesn't refresh - whatever text I feed it stays there. So, for example, I run this command: $ /usr/lib/xscreensaver/gltext -text "`cat /proc/acpi/thermal_zone/THRM/temperature`" and get a gltext window showing: temperature: 60 C I can manipulate it and format it as necessary, but as my CPU heats up and cools down, it doesn't update, even if I include time variables that do. I have a script that feeds gltext the time as the first line and the temp as the second line - and although the time updates continuously as the time changes, the temperature value remains the same as whenever the screensaver started. Is it possible to do what I want, which is change the text every 60 seconds if the temperature changes?

    Read the article

  • SMART Status Data Interpretation - Disk Utility

    - by Mah
    Last week my external harddisk (Seagate Barracuda 1.5TB in a custom enclosure) showed signs of failure (Disk Utility SMART Pre-failure status - several bad sectors) and I decided to change it. I bought a new HDD (Seagate Barracuda 2TB) and connected it to my Ubuntu box with a SATA to USB cable that could not report SMART status. I copied all the contents of the old HDD to the new HDD (one partition with rsync, the other with parted cp) and then gently replaced the old HDD with the new one inside my aluminum enclosure. For obscure reasons after reconnecting the new HDD through the old enclosure, the Linux box could not detect my partitions. I recovered the partitions with testdisk and restarted the computer. After the restart I checked the SMART status of the new HDD an I get this: Read Error Rate --------------- Normalized 108 Worst 99 Threshold 6 Value 16737944 I got a high value on the Seek Error Rate as well. Wondering why this happens I copied 2 GB directory from one partition to the other and rechecked the SMART status (5 minutes later). This time I got the following: Read Error Rate --------------- Normalized 109 Worst 99 Threshold 6 Value 24792504 As you see there has been an increase in the error rate. I am unable to interpret these numbers. Is my new hard disk already dying? What are the acceptable values in these fields for Seagate hard disks? Then why the assessment is still good? While I could get temperature and airflow temperature data from my old HDD, I can not fetch them for the new one. I noticed that my old hdd had got really hot sometimes. Is it possible that the enclosure is killing the harddisks due to high temperature?... Thanks