  • Outbound HTTP performance tuning recommendations

    - by Richard Gadsden
    I'll detail my exact setup below, but general recommendations for a better web-browsing experience will be useful. A nice checklist of things to try would be great! I have 600 users on a single site with an 8MB leased line. I get a lot of moans about the performance of "the internet" (ie web-browsing). What recommendations do the community have for speeding things up without just throwing more bandwidth at it? I expect I will end up buying some more, but good management tips are always valuable. My setup is this: Cisco PIX (515E) firewall on the edge of the network. It's just doing some basic NAT, and opening up a handful of ports to various bastion hosts (aka DMZ servers). The DMZ is just a switch that the servers are plugged into. ISA 2006 Enterprise array (two servers) connecting DMZ to the internal LAN, with WebSense Web Security filtering HTTP traffic so users can't look at porn or waste bandwidth on YouTube during working hours. I've done a few things - I've just switched my internal DNS over to use root hints, which halved DNS query latency from 500ms to 250ms. Well worth doing. I'm trying to cache more aggressively, but so much more of the internet is AJAXy and doesn't cache very well as compared to five years ago. Plus the 70GB of cache which felt like a lot a few years ago really isn't any more. I'm getting about 45% cache hits by number of requests, but only about 22% by size, ie larger objects are less likely to be cached. Latency seems to be part of the problem. Is that attributable to the bandwidth problem, or are there things I can look at to try to reduce latency even on heavily-loaded bandwidth?

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here. EDIT: I found another person who has the exact same problem as me: http://www.ibm.com/developerworks/forums/thread.jspa?messageID=14451763

    Read the article

  • JAWStats statspath error on windows

    - by crosenblum
    I have AWStats which works fine, and JAWStats I am trying to get working. I have tried back and forward slashes to get the program to read the dirdata files. I even moved the folder of dirdata outside of program files folder, in case it had problems with folder names with spaces in them. Here is my config file. // core config parameters $sConfigDefaultView = "thismonth.all"; $bConfigChangeSites = true; $bConfigUpdateSites = true; $sUpdateSiteFilename = "xml_update.php"; // individual site configuration // awstats092012.noname.jumpingcrab.com.txt $aConfig["site1"] = array( "statspath" => "C:\\Program Files\\AWStats\\DirData\\", "statsname" => "awstats[MM][YYYY].yourexample.com.txt", "updatepath" => "C:\\Program Files\\AWStats\\wwwroot\\cgi-bin\\awstats.pl\\", "siteurl" => "http://yourexample.com", "theme" => "default", "fadespeed" => 250, "password" => "", "includes" => "" ); Domain names changed to protect the innocent...:P Here is the error message: An error has occured: No AWStats Log Files Found JAWStats cannot find any AWStats log files in the specified directory: C:\Program Files\AWStats\DirData\ Is this the correct folder? Is your config name, site1, correct? Please refer to the installation instructions for more information.

    Read the article

  • NVidia ION and /dev/mapper/nvidia_... issues.

    - by Ritsaert Hornstra
    I have an NVidia ION board with 4 SATA ports and want to use that to run a Linux Server (CentOS 5.4). I first hooed up 3 HDs (that will be a RAID5 array) and a forth small boot HD. I first started to use the onboard RAID capability but that does not work correctly under Linux: the raid capacity is not a real RAID but uses lvm to define some arays. After setting the BIOS back to normal SATA mode and whiping the HDs, the first boot harddisk (/dev/sda) is seen as /dev/sda BEFORE mounting and after mounting as /dev/mapper/nvidia_. CentOS is unable to install on it (and grub is not installable on it either). So somehow the harddisk is still seen as if it belongs to some lvm volume. I tried to clean out the HD by issuing a few dd if=/dev/zero of=/dev/sda commands to wipe the starting cylinders and final cylinders but to no avail. Did anyone see this problem and did anyone find a solution? UPDATE When I create only a single ext3 partition on the first HD (/dev/mapper/nvidia_...) no LVM partitions are seen and I can boot from /dev/mapper/nvidia_.... Now the next step is to see how I can get rid of this folly.

    Read the article

  • Apache doesn't run multiple requests

    - by Reinderien
    I'm currently running this simple Python CGI script to test rudimentary IPC: #!/usr/bin/python -u import cgi, errno, fcntl, os, os.path, sys, time print("""Content-Type: text/html; charset=utf-8 <!doctype html> <html lang="en"> <head> <meta charset="utf-8" /> <title>IPC test</title> </head> <body> """) ftempname = '/tmp/ipc-messages' master = not os.path.exists(ftempname) if master: fmode = 'w' else: fmode = 'r' print('<p>Opening file</p>') sys.stdout.flush() ftemp = open(ftempname, fmode) print('<p>File opened</p>') if master: print('<p>Operating as master</p>') sys.stdout.flush() for i in range(10): print('<p>' + str(i) + '</p>') sys.stdout.flush() time.sleep(1) ftemp.close() os.remove(ftempname) else: print('<p>Operating as a slave</p>') ftemp.close() print(""" </body> </html>""") The 'server-push' portion works; that is, for the first request, I do see piecewise updates. However, while the first request is being serviced, subsequent requests are not started, only to be started after the first request has finished. Any ideas on why, and how to fix it? Edit: I see the same non-concurrent behaviour with vanilla PHP, running this: <!doctype html> <html lang="en"> <!-- $Id: $--> <head> <meta charset="utf-8" /> <title>IPC test</title> </head> <body> <p> <?php function echofl($str) { echo $str . "</b>\n"; ob_flush(); flush(); } define('tempfn', '/tmp/emailsync'); if (file_exists(tempfn)) $perms = 'r+'; else $perms = 'w'; assert($fsync = fopen(tempfn, $perms)); assert(chmod(tempfn, 0600)); if (!flock($fsync, LOCK_EX | LOCK_NB, $wouldblock)) { assert($wouldblock); $master = false; } else $master = true; if ($master) { echofl('Running as master.'); assert(fwrite($fsync, 'content') != false); assert(sleep(5) == 0); assert(flock($fsync, LOCK_UN)); } else { echofl('Running as slave.'); echofl(fgets($fsync)); } assert(fclose($fsync)); echofl('Done.'); ?> </p> </body> </html>

    Read the article

  • Are HDMI to VGA Adapters Really Device-Specific?

    - by allquixotic
    There are a lot of devices on the market right now (especially mobile devices) with a Micro-HDMI or Mini-HDMI port and no VGA or D-Sub output. Most manufacturers of said devices sell a cable that looks something like this: I have yet to find a cable like this that claims to work on a wide array of devices. In general, these cables claim to work with one specific device only. The way these cables work, I think, is that analog VGA signals are sent from the HDMI port on the device. This should work for devices that have special hardware on the motherboard/GPU capable of driving this. Is it the case that these cables have to be custom designed for each device? Or, is it rather that any device which possesses this special "signaling of analog VGA over the HDMI port" can be made to work with a cable that is physically compatible (i.e. the HDMI end plugs into the device and the VGA end accepts a VGA monitor cable)? Note that I am not looking for a product recommendation, just a conceptual clarification on what exactly these devices are doing. Also, a few remarks: The cables like the one depicted here are not digital to analog converters. I know about these: they are expensive, and they are the ONLY solution if your device only outputs a digital signal and is incapable of driving analog VGA over the HDMI port. The cables like the one depicted here are not straight crossover cables from VGA to HDMI, either. The crossover cables are designed to send a digital HDMI signal over the VGA port's wires; that is, the wire protocol is HDMI (digital) but the physical pinout is the same as VGA, even though nothing analog is happening. Once again, this is not the behavior that, I believe, the devices which I'm talking about in this question are doing. The cabling and devices that this question is about transmit the analog VGA data over the HDMI port (the HDMI port is in the device outputting the data, and the VGA side is the monitor/projector).

    Read the article

  • ZFS: Mirror vs. RAID-Z

    - by John Clayton
    I'm planning on building a file server using OpenSolaris and ZFS that will provide two primary services - be an iSCSI target for XenServer virtual machines & be a general home file server. The hardware I'm looking at includes 2x 4-port SATA controllers, 2x small boot drives (one on each controller), and 4x big drives for storage. This allows one free port per controller for upgrading the array down the road. Where I'm a little confused is how to setup the storage drives. For performance, mirroring appears to be king. I'm having a hard time seeing what the benefit would be of using RAIDZ over mirroring would be. With this setup I can see two options - two mirrored pools in one stripe, or RAIDZ2. Both should protect against 2 drive failures, and/or one controller failure...the only benefit of RAIDZ2 would be that any 2 drives could fail. The storage should be 50% of capacity in both cases, but the first should have much better performance, right? The other thing I'm trying to wrap my mind around is the benefit of mirrored arrays with more than two devices. For data integrity what, if any, would be the benefit of a RAIDZ over a three-way mirror? Since ZFS maintains file integrity what does RAIDZ bring to the table...doesn't ZFS's integrity checks negate the value of RAIDZ's parity?

    Read the article

  • Unable to authenticate to Windows Server 2003 for file browsing as non-administrator user.

    - by Fopedush
    I've got a windows server 2003 box containing a raid 5 array I use for mass storage. I want to set up a special non-administrator account that can be used to browse files over the network, with only read access. Ideally I'll map my network drive as this user to avoid accidentally hosing my data, and mount as an administrator user on occasions where I actually need write access. I've created a non-administrator user on the Windows Server box (called "ReadOnly)", and granted the user read permissions on the folders I need. However, when I try to browse to the files, and authenticate as this user, I'm told "Permission denied". If I throw the readOnly user into the administrators group, however, I can authenticate and browse just fine. I am, of course, only attempting to browse to folder for which I have given this user read permissions. Obviously my ReadOnly user is missing some privilege here, but I can't figure out what it is. I've been digging around in group policy editor all day to no avail. What am I missing? Fake Edit: I'm doing my browsing from a Windows 7 box, but I don't think that is relevant.

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Where do I connect the HDD LED wires on my RAID adapter?

    - by Giffyguy
    I'm using a Promise FastTrak TX8660 with RAID 5. The manual (and Google) just doesn't seem to explain how exactly to connect a standard two-pin HDD LED wire to the eight available pins on the card. The Manual just says - To connect your LED, follow the following diagram: The card itself resembles the diagram: But it doesn't make any sense to me. All I have is a two-pin connecter for HDD LED on the front of my computer case. I don't need anything fancy like the fault LED or seperate indicators for each drive. I just want to be able to see when my RAID 5 array is working, that's all. I don't know what the "R" and "G" stand for, but my HDD LED wires are red and white. I tried connecting the red wire to the "R" pin and the white wire to the "G" pin, but that just makes the LED on the front of my case light up indefinitely, even when the computer is idle. Which pins am I suppose to connect the HDD LED header to for basic activity indication?

    Read the article

  • Blocking 'good' bots in nginx with multiple conditions for certain off-limits URL's where humans can go

    - by Glenn Plas
    After 2 days of searching/trying/failing I decided to post this here, I haven't found any example of someone doing the same nor what I tried seems to be working OK. I'm trying to send a 403 to bots not respecting the robots.txt file (even after downloading it several times). Specifically Googlebot. It will support the following robots.txt definition. User-agent: * Disallow: /*/*/page/ The intent is to allow Google to browse whatever they can find on the site but return a 403 for the following type of request. Googlebot seems to keep on nesting these links eternally adding paging block after block: my_domain.com:80 - 66.x.67.x - - [25/Apr/2012:11:13:54 +0200] "GET /2011/06/ page/3/?/page/2//page/3//page/2//page/3//page/2//page/2//page/4//page/4//pag e/1/&wpmp_switcher=desktop HTTP/1.1" 403 135 "-" "Mozilla/5.0 (compatible; G ooglebot/2.1; +http://www.google.com/bot.html)" It's a wordpress site btw. I don't want those pages to show up, even though after the robots.txt info got through, they stopped for a while only to begin crawling again later. It just never stops .... I do want real people to see this. As you can see, google get a 403 but when I try this myself in a browser I get a 404 back. I want browsers to pass. root@my_domain:# nginx -V nginx version: nginx/1.2.0 I tried different approaches, using a map and plain old nono if's and they both act the same: (under http section) map $http_user_agent $is_bot { default 0; ~crawl|Googlebot|Slurp|spider|bingbot|tracker|click|parser|spider 1; } (under the server section) location ~ /(\d+)/(\d+)/page/ { if ($is_bot) { return 403; # Please respect the robots.txt file ! } } I recently had to polish up my Apache skills for a client where I did about the same thing like this : # Block real Engines , not respecting robots.txt but allowing correct calls to pass # Google RewriteCond %{HTTP_USER_AGENT} ^Mozilla/5\.0\ \(compatible;\ Googlebot/2\.[01];\ \+http://www\.google\.com/bot\.html\)$ [NC,OR] # Bing RewriteCond %{HTTP_USER_AGENT} ^Mozilla/5\.0\ \(compatible;\ bingbot/2\.[01];\ \+http://www\.bing\.com/bingbot\.htm\)$ [NC,OR] # msnbot RewriteCond %{HTTP_USER_AGENT} ^msnbot-media/1\.[01]\ \(\+http://search\.msn\.com/msnbot\.htm\)$ [NC,OR] # Slurp RewriteCond %{HTTP_USER_AGENT} ^Mozilla/5\.0\ \(compatible;\ Yahoo!\ Slurp;\ http://help\.yahoo\.com/help/us/ysearch/slurp\)$ [NC] # block all page searches, the rest may pass RewriteCond %{REQUEST_URI} ^(/[0-9]{4}/[0-9]{2}/page/) [OR] # or with the wpmp_switcher=mobile parameter set RewriteCond %{QUERY_STRING} wpmp_switcher=mobile # ISSUE 403 / SERVE ERRORDOCUMENT RewriteRule .* - [F,L] # End if match This does a bit more than I asked nginx to do but it's about the same principle, I'm having a hard time figuring this out for nginx. So my question would be, why would nginx serve my browser a 404 ? Why isn't it passing, The regex isn't matching for my UA: "Mozilla/5.0 (X11; Linux x86_64) AppleWebKit/536.5 (KHTML, like Gecko) Chrome/19.0.1084.30 Safari/536.5" There are tons of example to block based on UA alone, and that's easy. It also looks like the matchin location is final, e.g. it's not 'falling' through for regular user, I'm pretty certain that this has some correlation with the 404 I get in the browser. As a cherry on top of things, I also want google to disregard the parameter wpmp_switcher=mobile , wpmp_switcher=desktop is fine but I just don't want the same content being crawled multiple times. Even though I ended up adding wpmp_switcher=mobile via the google webmaster tools pages (requiring me to sign up ....). that also stopped for a while but today they are back spidering the mobile sections. So in short, I need to find a way for nginx to enforce the robots.txt definitions. Can someone shell out a few minutes of their lives and push me in the right direction please ? I really appreciate ANY response that makes me think harder ;-)

    Read the article

  • 24TB RAID 6 configuration

    - by Phil
    I am in charge of a new website in a niche industry that stores lots of data (10+ TB per client, growing to 2 or 3 clients soon). We are considering ordering about $5000 worth of 3TB drives (10 in a RAID 6 configuration and 10 for backup), which will give us approximately 24 TB of production storage. The data will be written once and remain unmodified for the lifetime of the website, so we only need to do a backup one time. I understand basic RAID theory, however I am not experienced with it. My question is, does this sound like a good configuration? What potential problems could this setup cause? Also, what is the best way to do a one-time backup? Have two RAID 6 arrays, one for offsite backup and one for production? Or should I backup the RAID 6 production array to a JBOD? EDIT: The data server is running Windows 2008 Server x64. EDIT 2: To reduce rebuild time, what would you think about using two RAID 5's instead of one RAID 6?

    Read the article

  • Repairing inconsistent pages in database

    - by Raj
    We have a SQL 2000 DB. The server crashed due to Raid array failure. Now when we run DBCC CHECKDB, we get an error that there are 27 consistency errors in 9 pages. When we run DBCC PAGE on these pages, we get this: Msg 8939, Level 16, State 106, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (m_freeCnt == freeCnt) failed. Values are 2 and 19. Msg 8939, Level 16, State 108, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (emptySlotCnt == 0) failed. Values are 1 and 0. Since the indicated index is non-clustered and is created by a unique constarint that includes 2 columns, we tried dropping and recreating the index. This resulted in the following error: CREATE UNIQUE INDEX terminated because a duplicate key was found for index ID 2. Most significant primary key is '3280'. The statement has been terminated. However running Select var_id,result_on from tests group by var_id,result_on having count(*)>1 returns 0 rows. Here is what we are planning to do: Restore a pre-server crash copy of the DB and run DBCC CHECKDB If that returns clean, then restore again with no recovery Apply all subequent TLOG backups Stop production app, take a tail log backup and apply that too Drop prod DB and rename the freshly restored DB to make it prod Start prod app Could someone please punch holes in this approach? Maybe, suggest a different approach? What we need is minimum downtime. SQL 2000 DB Size 94 GB The table that has corrupt pages has 460 Million+ rows of data Thanks for the help. Raj

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • how does openvpn decide which interface to get IP addrs from

    - by bkrupa
    Using ubuntu 10.04 on both ends. We have a client and server machine on the SAME network attempting to make a vpn connection. We use the config files from here and made minimal changes. The server and client start and seem to connect without any trouble. The server looks like: Wed Feb 23 22:13:22 2011 MULTI: multi_create_instance called Wed Feb 23 22:13:22 2011 192.168.1.55:47166 Re-using SSL/TLS context Wed Feb 23 22:13:22 2011 192.168.1.55:47166 LZO compression initialized Wed Feb 23 22:13:22 2011 192.168.1.55:47166 Control Channel MTU parms [ L:1574 D:138 EF:38 EB:0 ET:0 EL:0 ] Wed Feb 23 22:13:22 2011 192.168.1.55:47166 Data Channel MTU parms [ L:1574 D:1450 EF:42 EB:135 ET:32 EL:0 AF:3/1 ] Wed Feb 23 22:13:22 2011 192.168.1.55:47166 Local Options hash (VER=V4): 'f7df56b8' Wed Feb 23 22:13:22 2011 192.168.1.55:47166 Expected Remote Options hash (VER=V4): 'd79ca330' Wed Feb 23 22:13:22 2011 192.168.1.55:47166 TLS: Initial packet from 192.168.1.55:47166, sid=69112e42 5458135b *...* Wed Feb 23 22:13:22 2011 192.168.1.55:47166 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Wed Feb 23 22:13:22 2011 192.168.1.55:47166 [client1] Peer Connection Initiated with 192.168.1.55:47166 On the client side the connection looks like: Wed Feb 23 22:20:07 2011 [server] Peer Connection Initiated with [AF_INET]192.168.1.41:1194 Wed Feb 23 22:20:10 2011 SENT CONTROL [server]: 'PUSH_REQUEST' (status=1) Wed Feb 23 22:20:10 2011 PUSH: Received control message: 'PUSH_REPLY,route-gateway 10.8.0.4,ping 10,ping-restart 120,ifconfig 10.8.0.50 255.255.255.0' ... Wed Feb 23 22:20:10 2011 /sbin/ifconfig tap0 10.8.0.50 netmask 255.255.255.0 mtu 1500 broadcast 10.8.0.255 Wed Feb 23 22:20:10 2011 Initialization Sequence Completed The openvpn server has been configured to assign ip addresses in the range 10.8.0.* and the client has been given 10.8.0.50. When I run the following nmap from the client: Starting Nmap 5.00 ( http://nmap.org ) at 2011-02-23 22:04 EST Host 10.8.0.50 is up (0.00047s latency). Nmap done: 256 IP addresses (1 host up) scanned in 30.34 seconds Host 192.168.1.1 is up (0.0025s latency). Host 192.168.1.18 is up (0.074s latency). Host 192.168.1.41 is up (0.0024s latency). Host 192.168.1.55 is up (0.00018s latency). Nmap done: 256 IP addresses (4 hosts up) scanned in 6.33 seconds If I run an nmap from the server on 10.8.0.* I get nothing. If the client has two interfaces (wireless and tap device) when you look for a certain ip address, how does it decide which interface to connect on? edit I am trying to set up a vpn so that I can connect to my home network from a remote network. It seems like openvpn is connecting but none of the computers on my home network appear as network machines even after the connection is "Established". Stripped versions of the client and server config files are posted below. Thanks for any help you can offer. server.conf port 1194 proto udp dev tap ca /etc/openvpn/easy-rsa/keys/ca.crt cert /etc/openvpn/easy-rsa/keys/server.crt key /etc/openvpn/easy-rsa/keys/server.key # This file should be kept secret dh /etc/openvpn/easy-rsa/keys/dh1024.pem ifconfig-pool-persist ipp.txt server-bridge 10.8.0.4 255.255.255.0 10.8.0.50 10.8.0.100 keepalive 10 120 comp-lzo persist-key persist-tun status openvpn-status.log verb 3 client.conf client dev tap dev-node tap0901 proto udp remote ********** 1194 resolv-retry infinite nobind persist-key persist-tun ca ca.crt cert client1.crt key client1.key comp-lzo verb 3 one other thing that might be helpful, I tried to connect using the openvpn gui for windows and the connection stalls out on "obtaining configuration" and the bar just scrolls forever.

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here.

    Read the article

  • Disk IO slow on ESXi, even slower on a VM (freeNAS + iSCSI)

    - by varesa
    I have a server with ESXi 5 and iSCSI attached network storage(4x1Tb Raid-Z on freenas 8.0.4). Those two machines are connected to each other with Gigabit ethernet. The raid-z volume is divided into three parts: two zvols, shared with iscsi, and one directly on top of zfs, shared with nfs and similar. I ssh'd into the freeNAS box, and did some testing on the disks. I used ddto test the third part of the disks (straight on top of ZFS). I copied a 4GB (2x the amount of RAM) block from /dev/zero to the disk, and the speed was 80MB/s. Other of the iSCSI shared zvols is a datastore for the ESXi. I did similar test with time dd .. there. Since the dd there did not give the speed, I divided the amount of data transfered by the time show by time. The result was around 30-40 MB/s. Thats about half of the speed from the freeNAS host! Then I tested the IO on a VM running on the same ESXi host. The VM was a light CentOS 6.0 machine, which was not really doing anything else at that time. There were no other VMs running on the server at the time, and the other two "parts" of the disk array were not used. A similar dd test gave me result of about 15-20 MB/s. That is again about half of the result on a lower level! Of course the is some overhead in raid-z - zfs - zvolume - iSCSI - VMFS - VM, but I don't expect it to be that big. I belive there must be something wrong in my system. I have heard about bad performance of freeNAS's iSCSI, is that it? I have not managed to get any other "big" SAN OS to run on the box (NexentaSTOR, openfiler). Can you see any obvious problems with my setup?

    Read the article

  • How do you re-mount an ext3 fs readwrite after it gets mounted readonly from a disk error?

    - by cagenut
    Its a relatively common problem when something goes wrong in a SAN for ext3 to detect the disk write errors and remount the filesystem read-only. Thats all well and good, only when the SAN is fixed I can't figure out how to re-re-mount the filesystem read-write without rebooting. Behold: [root@localhost ~]# multipath -ll mpath0 (36001f93000a310000299000200000000) dm-2 XIOTECH,ISE1400 [size=1.1T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=2][active] \_ 1:0:0:1 sdb 8:16 [active][ready] \_ 2:0:0:1 sdc 8:32 [active][ready] [root@localhost ~]# mount /dev/mapper/mpath0 /mnt/foo [root@localhost ~]# touch /mnt/foo/blah All good, now I yank the LUN out from under it. [root@localhost ~]# touch /mnt/foo/blah [root@localhost ~]# touch /mnt/foo/blah touch: cannot touch `/mnt/foo/blah': Read-only file system [root@localhost ~]# tail /var/log/messages Mar 18 13:17:33 localhost multipathd: sdb: tur checker reports path is down Mar 18 13:17:34 localhost multipathd: sdc: tur checker reports path is down Mar 18 13:17:35 localhost kernel: Aborting journal on device dm-2. Mar 18 13:17:35 localhost kernel: Buffer I/O error on device dm-2, logical block 1545 Mar 18 13:17:35 localhost kernel: lost page write due to I/O error on dm-2 Mar 18 13:17:36 localhost kernel: ext3_abort called. Mar 18 13:17:36 localhost kernel: EXT3-fs error (device dm-2): ext3_journal_start_sb: Detected aborted journal Mar 18 13:17:36 localhost kernel: Remounting filesystem read-only It only thinks its read-only, in reality its not even there. [root@localhost ~]# multipath -ll sdb: checker msg is "tur checker reports path is down" sdc: checker msg is "tur checker reports path is down" mpath0 (36001f93000a310000299000200000000) dm-2 XIOTECH,ISE1400 [size=1.1T][features=0][hwhandler=0][rw] \_ round-robin 0 [prio=0][enabled] \_ 1:0:0:1 sdb 8:16 [failed][faulty] \_ 2:0:0:1 sdc 8:32 [failed][faulty] [root@localhost ~]# ll /mnt/foo/ ls: reading directory /mnt/foo/: Input/output error total 20 -rw-r--r-- 1 root root 0 Mar 18 13:11 bar How it still remembers that 'bar' file being there... mystery, but not important right now. Now I re-present the LUN: [root@localhost ~]# tail /var/log/messages Mar 18 13:23:58 localhost multipathd: sdb: tur checker reports path is up Mar 18 13:23:58 localhost multipathd: 8:16: reinstated Mar 18 13:23:58 localhost multipathd: mpath0: queue_if_no_path enabled Mar 18 13:23:58 localhost multipathd: mpath0: Recovered to normal mode Mar 18 13:23:58 localhost multipathd: mpath0: remaining active paths: 1 Mar 18 13:23:58 localhost multipathd: dm-2: add map (uevent) Mar 18 13:23:58 localhost multipathd: dm-2: devmap already registered Mar 18 13:23:59 localhost multipathd: sdc: tur checker reports path is up Mar 18 13:23:59 localhost multipathd: 8:32: reinstated Mar 18 13:23:59 localhost multipathd: mpath0: remaining active paths: 2 Mar 18 13:23:59 localhost multipathd: dm-2: add map (uevent) Mar 18 13:23:59 localhost multipathd: dm-2: devmap already registered [root@localhost ~]# multipath -ll mpath0 (36001f93000a310000299000200000000) dm-2 XIOTECH,ISE1400 [size=1.1T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=2][enabled] \_ 1:0:0:1 sdb 8:16 [active][ready] \_ 2:0:0:1 sdc 8:32 [active][ready] Great right? It says [rw] right there. Not so fast: [root@localhost ~]# touch /mnt/foo/blah touch: cannot touch `/mnt/foo/blah': Read-only file system OK, doesn't do it automatically, I'll just give it a little push: [root@localhost ~]# mount -o remount /mnt/foo mount: block device /dev/mapper/mpath0 is write-protected, mounting read-only Noooooooooo. I have tried all sorts of different mount/tune2fs/dmsetup commands and I cannot figure out how to get it to un-flag the block device as write-protected. Rebooting will fix it, but I'd much rather do it on-line. An hour of googling has gotten me nowhere either. Save me ServerFault.

    Read the article

  • RabbitMQ message consumers stop consuming messages

    - by Bruno Thomas
    Hi server fault, Our team is in a spike sprint to choose between ActiveMQ or RabbitMQ. We made 2 little producer/consumer spikes sending an object message with an array of 16 strings, a timestamp, and 2 integers. The spikes are ok on our devs machines (messages are well consumed). Then came the benchs. We first noticed that somtimes, on our machines, when we were sending a lot of messages the consumer was sometimes hanging. It was there, but the messsages were accumulating in the queue. When we went on the bench plateform : cluster of 2 rabbitmq machines 4 cores/3.2Ghz, 4Gb RAM, load balanced by a VIP one to 6 consumers running on the rabbitmq machines, saving the messages in a mysql DB (same type of machine for the DB) 12 producers running on 12 AS machines (tomcat), attacked with jmeter running on another machine. The load is about 600 to 700 http request per second, on the servlets that produces the same load of RabbitMQ messages. We noticed that sometimes, consumers hang (well, they are not blocked, but they dont consume messages anymore). We can see that because each consumer save around 100 msg/sec in database, so when one is stopping consumming, the overall messages saved per seconds in DB fall down with the same ratio (if let say 3 consumers stop, we fall around 600 msg/sec to 300 msg/sec). During that time, the producers are ok, and still produce at the jmeter rate (around 600 msg/sec). The messages are in the queues and taken by the consumers still "alive". We load all the servlets with the producers first, then launch all the consumers one by one, checking if the connexions are ok, then run jmeter. We are sending messages to one direct exchange. All consumers are listening to one persistent queue bounded to the exchange. That point is major for our choice. Have you seen this with rabbitmq, do you have an idea of what is going on ? Thank you for your answers.

    Read the article

  • Is it possible to have a wireless in-house NAS with wireless data transfer rates of equivalent to SATA speeds?

    - by techaddict
    Basically I would like to know, if it is possible to set up an NAS in my house to be accessed wirelessly, that can reach equivalent real-life data transfer speeds to USB 3.0 or an internal SATA hard drive. I have been wanting to do this for some time ( a couple of years now). Basically, this is what I want to do: Plug in a number of hard drives in an array, somewhere in my house, to be left plugged in and never have to be monitored. Ideally several terabytes. Whenever I am home, to have my computer and laptop configured to automatically find the NAS, as easy as plugging in an external hard drive - except completely wirelessly. Data transfer needs to be as seamless and quick as having added another internal hard drive in my laptop. Moreover, data should be able to accessed without having to copy it over - I should be able to wirelessly access the NAS and browse files, and open files directly from the NAS. For example, say I wanted to open a video - I should be able to play the video that is located on the NAS, directly from the NAS, completely wirelessly. If I wanted to open a .pdf file, I should be able to open it and read it directly from the NAS, as if it were located on my physical internal hard drive. Cost is important as well. Please tell me what equipment I need for this to be possible. I know you geniuses out there who can tell me if this is possible.

    Read the article

  • Very poor SCSI hd performance on IBM x336 with LSI 1030 RAID1

    - by David Tschoepe
    I'm experiencing very poor performance on an IBM x336 server with dual 73GB 15k hard drives on a U320 controller, LSI 1030. We're getting maybe 3.5MB/sec max (per HD Tune utility). It should be over 100MB/sec at least, I would think (another x335 box is running 70-80MB/sec). The server was recently setup and didn't really notice the problem, but may have been there from the beginning, so not sure. I have installed the IBM ServerRAID Windows utility. The server is running Windows 2008 R2 Web edition (if that matters). I thought maybe one of the drives was bad, so far I have removed one of the drives out of the array and tested again, but still the same results. I'm waiting for the RAID1 to resync and I will try pulling the other drive next. I've also used the ServerRAID utility but haven't noticed anything in there that might indicate a problem. Not sure if I'm on the right path here. So looking for some advice to track this down.

    Read the article

  • Performing mechanical movements using computer

    - by Vi
    How to make a computer (in particular, my laptop) to perform some mechanical movements without buying anything $5, soldering things inside computer or creating big sophisticated circuits? Traditionally CD-ROM tray is used to make computer do some movement IRL by, for example, SSH command, but in laptop tray is one-shot (unless manually reloaded) and also not very comfortable [mis]usage. Some assistance circuits can be in use too, but not complex. For example, there is a little motor that can work on USB power. Devices in my computer: DVD-ROM tray: one-time push. USB power: continuous power to the motor or LEDS or relay that turns on something powerful. Audio card. 3 outputs (modprobe alsa model=test can set Mic and Line-in as additional output). One controllable DC output (microphone) that can power up LED and some electronic (may be even mechanic?) relay. Also with sophisticated additional circuiting can control a lot of devices with a good precision. Both input and output support. Probably the most useful object in computer for radio ham. Modem. Don't know about this much, it doesn't work because of hsfmodem crashes kernel if memory is = 1GB. May be it's "pick up" and "hang up" can turn on and off power taken from USB port? Video card. VGA port? S-Video port? Will them be useful? Backlight. Tunable, but probably unuseful. CardBus (or some) slot. Nothing interesting for the task probably (is it?). AC adapter and battery. Probably nothing programmable here. /* My AC adapter already have additional jacks to connect extra devics */ Keyboard. No use. Touchpad. Good sensor (synclient -m 1), but no output. Various LEDs inside laptop. Probably too weak and requires soldering. Fans inside laptop. Poor control over them, requires soldering and dangerous to tinker. HDD (internal and external) that can be spin down and up (hdparm -Y, cat /dev/ubb). But connecting anything serially with it's power line makes HDD underpowered... And too complex. Is something are missed? Any ideas how to use described components? Any other ideas? May be there are easily available /* in developing countries */ cheap devices like "enhanced multimeters" that are controllable from computer and can provide configurable output and measure current and other things? Things to aid pushing many physical buttons with computer. Isn't this a simple idea and implementation and a lot of use in good hands?

    Read the article

  • How to set up a centralized backup server with lots of offsite workstations, intermittent internet connectivity, and stubborn users?

    - by Zac B
    This might be an impossible question. Context: We have a bunch of computers across around 1000 users. We have a centralized office where 900 of the users work, most of the time. Most of the computers are laptops. They are very frequently coming on and off the network for hours at a time. Users often take their computers home and do lots of work from home. In addition, there are a handful of users who work elsewhere in the country, who are offline (no internet connection whatsoever) for more than half of the time they use their machines. All of the machines are Windows 7/XP. Problem: People are always losing data. One day someone accidentally deletes a bunch of files. The next day someone else installs a bad driver or tries to mess with something in system32 and needs a personal data backup/reinstall of Windows. Because of how many of our business operations are done without an internet connection, and how frequently computers come on- and offline, it's unfeasible to make users use network storage for all of their data. We tried giving them Dropboxes, and they stored their files elsewhere. We bought and deployed Altiris, and they uninstalled it and blamed us when they couldn't get files back that they accidentally deleted while they were offline and hadn't taken a backup in months. We tried teaching them backup best-practices, and using scheduled sync tools to upload things to the network drives, and they turned them off because they "looked like viruses". It doesn't help that many of these users are pretty high up in the business and are not amicable to any sort of "you need to do something regularly because we say so" solution. Question: Other than finding another job where IT is treated differently and users are willing to follow best practices, how would people recommend I implement a file backup solution that supports the following: Backs up to a centralized server over LAN or WAN whenever a network link becomes available, or on a schedule. Supports interrupted/resumed backups (and hopefully file-delta only backups), since connections to the network (WAN or LAN) are often slow and only open for half an hour or so. Supports relatively rapid, "I accidentally deleted the TPS reports! Oh no!" single-file recovery, ideally administered from the central backup server rather than the client PC. Supports local-to-local file delta backup on a schedule, so that users without a network connection for a few days can still retrieve accidental deletions or whatnot. Ideally, the local stored backups would be pushed up to the server whenever network link is available. Isn't configurable on the clients without certain credentials. Because the CFOs (who won't give up their admin rights on the domain) will disable it if they can. Backs up the entire hard drive. There are people who are self-righteous about storing things in C:\, or in the recycle bin, or in the C:\Windows dir (yes, I know). I'm fine integrating multiple products/solutions, or scripting different programs together myself (I'm a somewhat competent programmer), but I've been drawing a blank on where to start. Dropbox is folder-specific, Altiris doesn't cope with LAN outages or interrupted/resumed backups, Volume Shadow Copy is awesome for a local-to-local solution, but I don't know how to push days of stored shadow copies up to a server in a 2 hour window of network access. The company is fine with spending decent money on this, thousands (USD) on a server, and hundreds on clients, if necessary. I want to emphasize that this isn't a shopping list request. While I wish there was a program out there that did what I want, I've looked pretty hard, and not found anything that fits the bill. Instead, I'm hoping for ideas on where to start hacking things together from scratch/from different technologies to make something stable that works. Cheers!

    Read the article

  • Why are SMART error rates going down?

    - by Jeff Shattock
    I have a hard drive that's part of a Linux software raid5 array. SMART has reported that its multi_zone_error_rate was 0, then 1, then 3. So I figured I better start backing up more frequently and prepare to replace the drive. Now, today, the multi_zone_error_rate of that very same drive is back down to 1. It seems that 2 errors unhappened while I wasn't looking. I've also seen simliar behaviour by inspecting the syslog on the server. Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 8 02:31:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 These are raw values, not the human-useful values that smartctl -a produces, but the behaviour is similar: error rates changing, then undoing the change. None of these are the drive that had the multi_zone weirdness. I haven't seen any problems from the RAID; its most recent scrub ( < 24 hours ago) came back totally clean. The only thing I can think of is that the SMART reporting circuitry on the drive isn't working properly all the time. The cables are in tight on the drive and board. What's going on here?

    Read the article