Search Results

Search found 24301 results on 973 pages for 'execution process mfg'.

Page 633/973 | < Previous Page | 629 630 631 632 633 634 635 636 637 638 639 640  | Next Page >

  • PySide Qt script doesn't launch from Spyder but works from shell

    - by Maxim Zaslavsky
    I have a weird bug in my project that uses PySide for its Qt GUI, and in response I'm trying to test with simpler code that sets up the environment. Here is the code I am testing with: http://stackoverflow.com/a/6906552/130164 When I launch that from my shell (python test.py), it works perfectly. However, when I run that script in Spyder, I get the following error: Traceback (most recent call last): File "/home/test/Desktop/test/test.py", line 31, in <module> app = QtGui.QApplication(sys.argv) RuntimeError: A QApplication instance already exists. If it helps, I also get the following warning: /usr/lib/pymodules/python2.6/matplotlib/__init__.py:835: UserWarning: This call to matplotlib.use() has no effect because the the backend has already been chosen; matplotlib.use() must be called *before* pylab, matplotlib.pyplot, or matplotlib.backends is imported for the first time. Why does that code work when launched from my shell but not from Spyder? Update: Mata answered that the problem happens because Spyder uses Qt, which makes sense. For now, I've set up execution in Spyder using the "Execute in an external system terminal" option, which doesn't cause errors but doesn't allow debugging, either. Does Spyder have any built-in workarounds to this?

    Read the article

  • Cache consistency & spawning a thread

    - by Dave Keck
    Background I've been reading through various books and articles to learn about processor caches, cache consistency, and memory barriers in the context of concurrent execution. So far though, I have been unable to determine whether a common coding practice of mine is safe in the strictest sense. Assumptions The following pseudo-code is executed on a two-processor machine: int sharedVar = 0; myThread() { print(sharedVar); } main() { sharedVar = 1; spawnThread(myThread); sleep(-1); } main() executes on processor 1 (P1), while myThread() executes on P2. Initially, sharedVar exists in the caches of both P1 and P2 with the initial value of 0 (due to some "warm-up code" that isn't shown above.) Question Strictly speaking – preferably without assuming any particular CPU – is myThread() guaranteed to print 1? With my newfound knowledge of processor caches, it seems entirely possible that at the time of the print() statement, P2 may not have received the invalidation request for sharedVar caused by P1's assignment in main(). Therefore, it seems possible that myThread() could print 0. References These are the related articles and books I've been reading. (It wouldn't allow me to format these as links because I'm a new user - sorry.) Shared Memory Consistency Models: A Tutorial hpl.hp.com/techreports/Compaq-DEC/WRL-95-7.pdf Memory Barriers: a Hardware View for Software Hackers rdrop.com/users/paulmck/scalability/paper/whymb.2009.04.05a.pdf Linux Kernel Memory Barriers kernel.org/doc/Documentation/memory-barriers.txt Computer Architecture: A Quantitative Approach amazon.com/Computer-Architecture-Quantitative-Approach-4th/dp/0123704901/ref=dp_ob_title_bk

    Read the article

  • Unable to change the system zone setting on Windows Server 2008 R2.

    - by Ganesh
    Hi All, I have an MFC application that tries to change the system zone setting on the Windows Server 2008 R2. I am using the SetTimeZoneInformation() API which fails with the error code 1314 .i.e. “A required privilege is not held by the client.”. Please refer the sample code below: TIME_ZONE_INFORMATION l_TimeZoneInfo; DWORD l_dwRetVal = 0; ZeroMemory(&l_TimeZoneInfo, sizeof(TIME_ZONE_INFORMATION)); l_TimeZoneInfo.Bias = -330; l_TimeZoneInfo.StandardBias = 0; l_TimeZoneInfo.StandardDate.wDay = 0; l_TimeZoneInfo.StandardDate.wDayOfWeek = 0; l_TimeZoneInfo.StandardDate.wHour = 0; l_TimeZoneInfo.StandardDate.wMilliseconds = 0; l_TimeZoneInfo.StandardDate.wMinute = 0; l_TimeZoneInfo.StandardDate.wMonth = 0; l_TimeZoneInfo.StandardDate.wSecond = 0; l_TimeZoneInfo.StandardDate.wYear = 0; CString l_csDaylightName = _T("India Daylight Time"); CString l_csStdName = _T("India Standard Time"); wcscpy(l_TimeZoneInfo.DaylightName,l_csDaylightName.GetBuffer(l_csDaylightName.GetLength())); wcscpy(l_TimeZoneInfo.StandardName,l_csStdName.GetBuffer(l_csStdName.GetLength())); ::SetLastError(0); if(0 == ::SetTimeZoneInformation(&l_TimeZoneInfo)) { l_dwRetVal = ::GetLastError(); CString l_csErr = _T(""); l_csErr.Format(_T("%d"),l_dwRetVal); } The MFC application has been developed using Visual Studio 2008 and is UAC aware i.e. the application has UAC enabled in its manifest file with the UAC execution level set to “HighestAvailable”. I have administrator privileges and when I run the application it still fails to change the system zone setting. Thanks in Advance, Ganesh

    Read the article

  • Best intro to C++ static metaprogramming?

    - by jwfearn
    Static metaprogramming (aka "template metaprogramming") is a great C++ technique that allows the execution of programs at compile-time. A light bulb went off in my head as soon as I read this canonical metaprogramming example: #include <iostream> using namespace std; template< int n > struct factorial { enum { ret = factorial< n - 1 >::ret * n }; }; template<> struct factorial< 0 > { enum { ret = 1 }; }; int main() { cout << "7! = " << factorial< 7 >::ret << endl; // 5040 return 0; } If one wants to learn more about C++ static metaprogramming, what are the best sources (books, websites, on-line courseware, whatever)?

    Read the article

  • DataTable won't DataBind with a DataTable.NewRow()

    - by David
    Is DataRow.NewRow() insufficient as the only row in a DataTable? I would expect this to work, but it doesn't. It's near the end of my Page_Load inside my If(!Postback) block. gridCPCP is GridView DataTable dt = new DataTable(); dt.Columns.Add("ID", int.MinValue.GetType()); dt.Columns.Add("Code", string.Empty.GetType()); dt.Columns.Add("Date", DateTime.MinValue.GetType()); dt.Columns.Add("Date2", DateTime.MinValue.GetType()); dt.Columns.Add("Filename", string.Empty.GetType()); //code to add rows if (dt.Rows.Count > 0) { gridCPCP.DataSource = dt; gridCPCP.DataBind(); } else { dt.Rows.Add(dt.NewRow()); gridCPCP.DataSource = dt; gridCPCP.DataBind(); //EXCEPTION int TotalColumns = gridCPCP.Rows[0].Cells.Count; gridCPCP.Rows[0].Cells.Clear(); gridCPCP.Rows[0].Cells.Add(new TableCell()); gridCPCP.Rows[0].Cells[0].ColumnSpan = TotalColumns; gridCPCP.Rows[0].Cells[0].Text = "No Record Found"; } The exception throws on gridCPCP.DataBind() and only when execution reaches the else block. If there were rows added above via dt.Rows.Add(new object[] { ... } binding works. System.ArgumentOutOfRangeException: Length cannot be less than zero. Parameter name: length

    Read the article

  • standard way to perform a clean shutdown with Boost.Asio

    - by Timothy003
    I'm writing a cross-platform server program in C++ using Boost.Asio. Following the HTTP Server example on this page, I'd like to handle a user termination request without using implementation-specific APIs. I've initially attempted to use the standard C signal library, but have been unable to find a design pattern suitable for Asio. The Windows example's design seems to resemble the signal library closest, but there's a race condition where the console ctrl handler could be called after the server object has been destroyed. I'm trying to avoid race conditions that cause undefined behavior as specified by the C++ standard. Is there a standard (correct) way to stop the server? So far: #include <csignal> #include <functional> #include <boost/asio.hpp> using std::signal; using boost::asio::io_service; extern "C" { static void handle_signal(int); } namespace { std::function<void ()> sighandler; } void handle_signal(int) { sighandler(); } int main() { io_service s; sighandler = std::bind(&io_service::stop, &s); auto res = signal(SIGINT, &handle_signal); // race condition? SIGINT raised before I could set ignore back if (res == SIG_IGN) signal(SIGINT, SIG_IGN); res = signal(SIGTERM, &handle_signal); // race condition? SIGTERM raised before I could set ignore back if (res == SIG_IGN) signal(SIGTERM, SIG_IGN); s.run(); // reset signals signal(SIGTERM, SIG_DFL); signal(SIGINT, SIG_DFL); // is it defined whether handle_signal can still be in execution at this // point? sighandler = nullptr; }

    Read the article

  • .Net Finalizer Order / Semantics in Esent and Ravendb

    - by mattcodes
    Help me understand. I've read that "The time and order of execution of finalizers cannot be predicted or pre-determined" Correct? However looking at RavenDB source code TransactionStorage.cs I see this ~TransactionalStorage() { try { Trace.WriteLine( "Disposing esent resources from finalizer! You should call TransactionalStorage.Dispose() instead!"); Api.JetTerm2(instance, TermGrbit.Abrupt); } catch (Exception exception) { try { Trace.WriteLine("Failed to dispose esent instance from finalizer because: " + exception); } catch { } } } The API class (which belongs to Managed Esent) which presumable takes handles on native resources presumably using a SafeHandle? So if I understand correctly the native handles SafeHandle can be finalized before TransactionStorage which could have undesired effects, perhaps why Ayende has added an catch all clause around this? Actually diving into Esent code, it does not use SafeHandles. According to CLR via C# this is dangerous? internal static class SomeType { [DllImport("Kernel32", CharSet=CharSet.Unicode, EntryPoint="CreateEvent")] // This prototype is not robust private static extern IntPtr CreateEventBad( IntPtr pSecurityAttributes, Boolean manualReset, Boolean initialState, String name); // This prototype is robust [DllImport("Kernel32", CharSet=CharSet.Unicode, EntryPoint="CreateEvent")] private static extern SafeWaitHandle CreateEventGood( IntPtr pSecurityAttributes, Boolean manualReset, Boolean initialState, String name) public static void SomeMethod() { IntPtr handle = CreateEventBad(IntPtr.Zero, false, false, null); SafeWaitHandle swh = CreateEventGood(IntPtr.Zero, false, false, null); } } Managed Esent (NativeMEthods.cs) looks like this (using Ints vs IntPtrs?): [DllImport(EsentDll, CharSet = EsentCharSet, ExactSpelling = true)] public static extern int JetCreateDatabase(IntPtr sesid, string szFilename, string szConnect, out uint dbid, uint grbit); Is Managed Esent handling finalization/dispoal the correct way, and second is RavenDB handling finalizer the corret way or compensating for Managed Esent?

    Read the article

  • Whats wrong with this piece of code?

    - by cambr
    vector<int>& mergesort(vector<int> &a) { if (a.size() == 1) return a; int middle = a.size() / 2; vector<int>::const_iterator first = a.begin(); vector<int>::const_iterator mid = a.begin() + (middle - 1); vector<int>::const_iterator last = a.end(); vector<int> ll(first, mid); vector<int> rr(mid, last); vector<int> l = mergesort(ll); vector<int> r = mergesort(rr); vector<int> result; result.reserve(a.size()); int dp = 0, lp = 0, rp = 0; while (dp < a.size()) { if (lp == l.size()) { result[dp] = (r[rp]); rp++; } else if (rp == r.size()) { result[dp] = (l[lp]); lp++; } else if (l[lp] < r[rp]) { result[dp] = (l[lp]); lp++; } else { result[dp] = (r[rp]); rp++; } dp++; } a = result; return a; } It compiles coorectly but while execution, I am getting: This application has requested the runtime to end it in an unusual way. This is a weird error. Is there something that is fundamentally wrong with the code?

    Read the article

  • How to show form in front in C#

    - by corlettk
    Folks, Please does anyone know how to show a Form from an otherwise invisible application, and have it get the focus (i.e. appear on top of other windows)? I'm working in C# .NET 3.5. I suspect I've taken "completely the wrong approach"... I do not Application.Run(new TheForm ()) instead I (new TheForm()).ShowModal()... The Form is basically a modal dialogue, with a few check-boxes; a text-box, and OK and Cancel Buttons. The user ticks a checkbox and types in a description (or whatever) then presses OK, the form disappears and the process reads the user-input from the Form, Disposes it, and continues processing. This works, except when the form is show it doesn't get the focus, instead it appears behind the "host" application, until you click on it in the taskbar (or whatever). This is a most annoying behaviour, which I predict will cause many "support calls", and the existing VB6 version doesn't have this problem, so I'm going backwards in usability... and users won't accept that (and nor should they). So... I'm starting to think I need to rethink the whole shebang... I should show the form up front, as a "normal application" and attach the remainer of the processing to the OK-button-click event. It should work, But that will take time which I don't have (I'm already over time/budget)... so first I really need to try to make the current approach work... even by quick-and-dirty methods. So please does anyone know how to "force" a .NET 3.5 Form (by fair means or fowl) to get the focus? I'm thinking "magic" windows API calls (I know Twilight Zone: This only appears to be an issue at work, we're I'm using Visual Studio 2008 on Windows XP SP3... I've just failed to reproduce the problem with an SSCCE (see below) at home on Visual C# 2008 on Vista Ulimate... This works fine. Huh? WTF? Also, I'd swear that at work yesterday showed the form when I ran the EXE, but not when F5'ed (or Ctrl-F5'ed) straight from the IDE (which I just put up with)... At home the form shows fine either way. Totaly confusterpating! It may or may not be relevant, but Visual Studio crashed-and-burned this morning when the project was running in debug mode and editing the code "on the fly"... it got stuck what I presumed was an endless loop of error messages. The error message was something about "can't debug this project because it is not the current project, or something... So I just killed it off with process explorer. It started up again fine, and even offered to recover the "lost" file, an offer which I accepted. using System; using System.Windows.Forms; namespace ShowFormOnTop { static class Program { [STAThread] static void Main() { Application.EnableVisualStyles(); Application.SetCompatibleTextRenderingDefault(false); //Application.Run(new Form1()); Form1 frm = new Form1(); frm.ShowDialog(); } } } Background: I'm porting an existing VB6 implementation to .NET... It's a "plugin" for a "client" GIS application called MapInfo. The existing client "worked invisibly" and my instructions are "to keep the new version as close as possible to the old version", which works well enough (after years of patching); it's just written in an unsupported language, so we need to port it. About me: I'm pretty much a noob to C# and .NET generally, though I've got a bottoms wiping certificate, I have been a professional programmer for 10 years; So I sort of "know some stuff". Any insights would be most welcome... and Thank you all for taking the time to read this far. Consiseness isn't (apparently) my forte. Cheers. Keith.

    Read the article

  • PHP Error handling in WordPress plugin

    - by AaronM
    I am a newbie to both PHP and Wordpress (but do ok in C#), and am struggling to understand the error handling in a custom plugin I am attempting to write. The basics of the plugin is to query an exsiting MSSQL database (note its not the standard MYSQL db...) and return the rows back to the screen. This was working well, but the hosting provider has taken my database offline, which led me to the error handling problem (which I thought was ok). The following code is failing to connect to the database (as expected), but puts an error onto the screen and stops the page processing. It does not even output the 'or die' error text. QUESTION: How can I just output a simple "Cant load data" message, and continue on normally? function generateData() { global $post; if ("$post->post_title" == "Home") { try { $myServer = "<servername>"; $myUser = "<username>"; $myPass = "<password>"; $myDB = "<dbName>"; //connection to the database $dbhandle = mssql_connect($myServer, $myUser, $myPass) or die("Couldn't open database $myDB"); //... query processing here... } catch (Exception $e) { echo "Cannot load data<br />"; } } return $content; } Error being generated: (line 31 is $dbhandle = mssql_connect...) Warning: mssql_connect() [function.mssql-connect]: Unable to connect to server: <servername> in <file path> on line 31 Fatal error: Maximum execution time of 30 seconds exceeded in <file path> on line 31

    Read the article

  • BackgroundWorker might be causing my application to hang

    - by alexD
    I have a Form that uses a BackgroundWorker to execute a series of tests. I use the ProgressChanged event to send messages to the main thread, which then does all of the updates on the UI. I've combed through my code to make sure I'm not doing anything to the UI in the background worker. There are no while loops in my code and the BackgroundWorker has a finite execution time (measured in seconds or minutes). However, for some reason when I lock my computer, often times the application will be hung when I log back in. The thing is, the BackgroundWorker isn't even running when this happens. The reason I believe it is related to the BackgroundWorker though is because the form only hangs when the BackgroundWorker has been executed since the application was loaded (it only runs when given a certain user input). I pass this thread a List of TreeNodes from a TreeView in my UI through the RunWorkerAsync method, but I only read those nodes in the worker thread..any modifications I make to them is done in the UI thread through the progressChanged event. I do use Thread.Sleep in my worker thread to execute tests at timed intervals (which involves sending messages over a TCP socket, which was not created in the worker thread). I am completely perplexed as to why my application might be hanging. I'm sure I'm doing something 'illegal' somewhere, I just don't know what.

    Read the article

  • Total Order between !different! volatile variables?

    - by andreas
    Hi all, Consider the following Java code: volatile boolean v1 = false; volatile boolean v2 = false; //Thread A v1 = true; if (v2) System.out.println("v2 was true"); //Thread B v2 = true; if (v1) System.out.println("v1 was true"); If there was a globally visible total order for volatile accesses then at least one println would always be reached. Is that actually guaranteed by the Java Standard? Or is an execution like this possible: A: v1 = true; B: v2 = true; A: read v2 = false; B: read v1 = false; A: v2 = true becomes visible (after the if) B: v1 = true becomes visible (after the if) I could only find statements about accesses to the same volatile variable in the Standard (but I might be missing something). "A write to a volatile variable (§8.3.1.4) v synchronizes-with all subsequent reads of v by any thread (where subsequent is defined according to the synchronization order)." http://java.sun.com/docs/books/jls/third_edition/html/memory.html#17.4.4 Thanks!

    Read the article

  • Thread Local Memory, Using std::string's internal buffer for c-style Scratch Memory.

    - by Hassan Syed
    I am using Protocol Buffers and OpensSSL to generate, HMACs and then CBC encrypt the two fields to obfuscate the session cookies -- similar Kerberos tokens. Protocol Buffers' API communicates with std::strings and has a buffer caching mechanism; I exploit the caching mechanism, for successive calls in the the same thread, by placing it in thread local memory; additionally the OpenSSL HMAC and EVP CTX's are also placed in the same thread local memory structure ( see this question for some detail on why I use thread local memory and the massive amount of speedup it enables even with a single thread). The generation and deserialization, "my algorithms", of these cookie strings uses intermediary void *s and std::strings and since Protocol Buffers has an internal memory retention mechanism I want these characteristics for "my algorithms". So how do I implement a common scratch memory ? I don't know much about the rdbuf(streambuf - strinbuf ??) of the std::string object. I would presumeably need to grow it to the lowest common size ever encountered during the execution of "my algorithms". Thoughts ? My question I guess would be: " is the internal buffer of a string re-usable, and if so, how ?" Edit: See comments to Vlad's answer please.

    Read the article

  • Java performance issue

    - by Colby77
    Hi, I've got a question related to java performance and method execution. In my app there are a lot of place where I have to validate some parameter, so I've written a Validator class and put all the validation methods into it. Here is an example: public class NumberValidator { public static short shortValidator(String s) throws ValidationException{ try{ short sh = Short.parseShort(s); if(sh < 1){ throw new ValidationException(); } return sh; }catch (Exception e) { throw new ValidationException("The parameter is wrong!"); } } ... But I'm thinking about that. Is this OK? It's OO and modularized, but - considering performance - is it a good idea? What if I had awful lot of invocation at the same time? The snippet above is short and fast, but there are some methods that take more time. What happens when there are a lot of calling to a static method or an instance method in the same class and the method is not synchronized? All the calling methods have to fall in line and the JVM executes them sequentially? Is it a good idea to have some class that are identical to the above-mentioned and randomly call their identical methods? I think it is not, because "Don't repeat yourself " and "Duplication is Evil" etc. But what about performance? Thanks is advance.

    Read the article

  • Perl IO modules possibly causing issues in Net::DNS module

    - by Rich
    Hi! I’m porting some software that I wrote for a White Russian OpenWRT system to a new Kamikaze 8.09.1 OpenWRT system but I am having some serious issues that I’m hoping you can help me with. Old system Linux kernel 2.4.34 MIPSEL arch Perl 5.8.7 Net::DNS 0.48 IO 1.21 IO::Socket 1.28 IO::Socket::INET 1.28 New system Linux kernel 2.6.26.8 MIPS arch Perl 5.10.0 Net::DNS 0.66 IO 1.23_01 IO::Socket 1.30_01 IO::Socket::INET 1.31 First, let me provide some background information… I am trying to resolve my server (clearprobe.winbeam.com) from within my Perl program and see the following if I enable debugging in Net::DNS: resolve: Server 'clearprobe-ddns.winbeam.com' ;; query(clearprobe-ddns.winbeam.com) ;; setting up an AF_INET() family type UDP socket ;; send_udp(192.168.88.1:53) ;; send_udp(4.2.2.2:53) ;; send_udp(192.168.88.1:53) ;; send_udp(4.2.2.2:53) resolve: res->errorstring: query timed out Both of these servers resolve clearprobe.winbeam.com fine from the command line: root@cwb-2-11:~# echo “nameserver 192.168.88.1” > /etc/resolv.conf root@cwb-2-11:~# nslookup clearprobe-ddns.winbeam.com Server: 192.168.88.1 Address 1: 192.168.88.1 router Name: clearprobe-ddns.winbeam.com Address 1: 64.13.48.40 64-13-48-40.war.clearwire-dns.net root@cwb-2-11:~# echo “nameserver 4.2.2.2” > /etc/resolv.conf root@cwb-2-11:~# nslookup clearprobe-ddns.winbeam.com Server: 4.2.2.2 Address 1: 4.2.2.2 vnsc-bak.sys.gtei.net Name: clearprobe-ddns.winbeam.com Address 1: 64.13.48.40 64-13-48-40.war.clearwire-dns.net Using Perl’s call to the C gethostbyaddr() function works fine, but I need to do another lookup later in the software which requires that I specify the nameserver (clearprobe-ddns.winbeam.com is the authority for my internal DNS zone), hence my Net::DNS requirement. Now, here is the IO module-specific information: What I am seeing is that the reply is coming back from the nameserver (confirmed via tcpdump – I can send the captures if you’d like), but the UDP packets are sitting in the process’s UDP receive queue pending reception by Net::DNS (the approx 1752 bytes per response stay queued waiting for $sel-can_read()): root@cwb-2-11:~# netstat -una Active Internet connections (servers and established) Proto Recv-Q Send-Q Local Address Foreign Address State udp 1752 0 0.0.0.0:52680 0.0.0.0:* root@cwb-2-11:~# netstat -una Active Internet connections (servers and established) Proto Recv-Q Send-Q Local Address Foreign Address State udp 5256 0 0.0.0.0:52680 0.0.0.0:* If I force $sock[AF_INET]-recv($buf, $self-_packetsz) around line 803 of /usr/lib/perl5/5.10/Net/DNS/Resolver/Base.pm, instead of waiting for IO::Select’s can_read() function ( @ready = $sel-can_read($timeout)) to populate @ready, the response is received and processed. Any idea what could be causing this issue? In a possibly related matter, I noticed in another script that the following code fails in the same manner (network responses stay in the process’s TCP receive queue) with the new system: $sock = new IO::Socket::INET( PeerAddr => "$server", PeerPort => 37, Proto => 'tcp', Timeout => 5 ); Whereas the following code works: $sock = new IO::Socket::INET( PeerAddr => "$server", PeerPort => 37, Proto => 'tcp' ); I have looked through the NET::DNS code and don’t see a timeout passed for the UDP sockets, so I am not sure if that this is related or not. Please let me know if I can provide you with any further information in order to help diagnose this issue. Thanks! -Rich

    Read the article

  • Multiple threads modifying a collection in Java??

    - by posdef
    Hi, The project I am working on requires a whole bunch of queries towards a database. In principle there are two types of queries I am using: read from excel file, check for a couple of parameters and do a query for hits in the database. These hits are then registered as a series of custom classes. Any hit may (and most likely will) occur more than once so this part of the code checks and updates the occurrence in a custom list implementation that extends ArrayList. for each hit found, do a detail query and parse the output, so that the classes created in (I) get detailed info. I figured I would use multiple threads to optimize time-wise. However I can't really come up with a good way to solve the problem that occurs with the collection these items are stored in. To elaborate a little bit; throughout the execution objects are supposed to be modified by both (I) and (II). I deliberately didn't c/p any code, as it would be big chunks of code to make any sense.. I hope it make some sense with the description above. Thanks,

    Read the article

  • Error handling in PHP

    - by Industrial
    Hi guys, We're building a PHP app based on Good old MVC (codeigniter framework) and have run into trouble with a massive chained action that consists of multiple model calls, that together is a part of a big transaction to the database. We want to be able to do a list of actions and get a status report of each one back from the function, whatever the outcome is. Our first initial idea was to utilize the exceptions of PHP5, but since we want to also need status messages that doesnt break the execution of the script, this was our solution that we came up with. It goes a little something like this: $sku = $this->addSku( $name ); if ($sku === false) { $status[] = 'Something gone terrible wrong'; $this->db->trans_rollback(); return $status; } $image= $this->addImage( $filename); if ($image=== false) { $error[] = 'Image could not be uploaded, check filesize'; $this->db->trans_rollback(); return $status; } Our controller looks like this: $var = $this->products->addProductGroup($array); if (is_array($var)) { foreach ($var as $error) { echo $error . '<br />'; } } It appears to be a very fragile solution to do what we need, but it's neither scalable, neither effective when compared to pure PHP exceptions for instance. Is this really the way that this kind of stuff generally is handled in MVC based apps? Thanks!

    Read the article

  • Qt - QWebView Problem

    - by user547057
    Hi, I have a PyQt gui script which consists of a QWebView widget. I'm trying to send a GET request, i.e go to a page, fill a form and hit click using the code at the bottom of this question. Since i'm dealing with the documentElement(a QWebElement) of the webview, I need to place all DOM actions in a separate function(which I have named fillForm) and connect the loadFinished() signal into the function. Without connecting the signal, the document will not have loaded and I won't be able to get the elements I want. I'm able to submit the form correctly and get the proper response from the webpage. The problem i'm having is that, the above leads to a sort of infinite loop. This is because the webpage gets reloaded each time a new page is loaded, so the form gets filled each and every single time without stopping. I'd like to know if there's some way of finding out whether the WebView's page has loaded fully, non-asynchronously or maybe pause execution of the script(without freezing the gui) until the whole document has loaded. I'm unable to come up with a satisfactory solution(my idea consisted of keeping a global variable to track clicks) to this problem. I would appreciate it if someone could help me out with a better way to tackle this. Thanks! Here's the code i'm using import sys from PyQt4.QtCore import * from PyQt4.QtGui import * from PyQt4.QtWebKit import * from PyQt4 import QtCore app = QApplication(sys.argv) web = QWebView() web.load(QUrl("http://mywebsite.com")) def fillForm(): doc = web.page().mainFrame().documentElement() searchform = doc.findFirst("input[type=text]") searchform.setAttribute("value", "hello") button = doc.findFirst("input[type=submit]") button.evaluateJavaScript("click()") QtCore.QObject.connect(web, QtCore.SIGNAL("loadFinished"), fillForm) web.show() sys.exit(app.exec_())

    Read the article

  • Zend Framework :: Is this code good for user login (Its begining- because that I want to know if its

    - by Yosef
    Hi, I new in Zend. Main Question: Is this code good for user login (Its beginning- because that I want to know if its can be improve)? Code understanding question: Is every time that in action call to his view- code execution in action not going to next row until view request? (I asking about IndexAction that I write down) Thanks view index.phtml <? echo $this->form controller IndexAction.php public function indexAction() { $form=new Application_Form_Login(); $this->view->form = $form; if ($this->getRequest()->isPost()) { $formData = $this->getRequest()->getPost(); if ($form->isValid($formData)) { echo " test value username: ".$form->getValue('username'); } } } form Login.php public function init() { $this->setMethod('post'); $this->setName('user login'); $username = new Zend_Form_Element_Text('username'); $username->setLabel("username") ->setRequired(true) ->addFilter('StripTags') ->addFilter('StringTrim') ->addValidator('NotEmpty'); $password = new Zend_Form_Element_Password('password'); $password->setLabel('password') ->setRequired(true) ->addFilter('StripTags') ->addFilter('StringTrim') ->addValidator('NotEmpty'); $submit = new Zend_Form_Element_Submit('submit'); $this->addElements(array($username, $password, $submit)); }

    Read the article

  • ReportServer 2005 Custom Assembly Error

    - by user752083
    We have a reportserver on sql server 2005, it has previously been working on computer X which we are replacing with a computer Y. Computer X only had one default sql instance as our test environment, machine Y is a new machine with 2 sql instances, Y\TEST and Y\DEV. Both machines run Windows Server 2003 and Both have Sql Server 2005 installed together with Report Server We have not currently done any work on the DEV instance, just on the TEST instance. The reportserver is installed for TEST. SSRS previously worked as intended on X machine, and on Y\TEST its working for reports not using any custom code. However for some of the reports we are loading a custom assembly Localization. This assembly currently exists in following folders on server: C:\Program Files\Microsoft Visual Studio 8\Common7\IDE\PublicAssemblies C:\Program Files\Microsoft Visual Studio 8\Common7\IDE\PrivateAssemblies C:\Program Files\Microsoft SQL Server\MSSQL.2\Reporting Services\ReportServer\bin Also in rssrvpolicy.config, the entry for Report_Expressions_Default_Permissions has been changed from Execution to FullTrust (Although this was not necessary on the machine X). When attempting to upload the rdl files through the web interface, we get the following errors: Error while loading code module: ‘Localization, Version=1.0.0.0, Culture=neutral, PublicKeyToken=e302ddd55ecd694a’. Details: Could not load file or assembly 'Localization, Version=1.0.0.0, Culture=neutral, PublicKeyToken=e302ddd55ecd694a' or one of its dependencies. The system cannot find the file specified. (rsErrorLoadingCodeModule) Get Online Help There is an error on line 14 of custom code: [BC30451] Name 'Localization' is not declared. (rsCompilerErrorInCode) Get Online Help Does anyone know any other places with potential errors?

    Read the article

  • java.lang.IllegalAccessError in Windows xp

    - by Priya.S
    Hi I have installed NetBeens 6.9.1 in my windows xp system. java web application wokring fine. But i have not get web method in my java web application. its error occurring. Error Message : init: deps-module-jar: deps-ear-jar: deps-jar: wsimport-init: Created dir: D:\javaprg\projects\myApp\build\generated-sources\jax-ws wsimport-client-userServiceService: Created dir: D:\javaprg\projects\myApp\build\generated\jax-wsCache\userServiceService D:\javaprg\projects\myApp\nbproject\jaxws-build.xml:31: java.lang.IllegalAccessError: tried to access class com.sun.tools.ws.Invoker from class com.sun.tools.ws.ant.WrapperTask at com.sun.tools.ws.ant.WrapperTask.createClassLoader(WrapperTask.java:85) at com.sun.istack.tools.ProtectedTask.execute(ProtectedTask.java:46) at org.apache.tools.ant.UnknownElement.execute(UnknownElement.java:291) at sun.reflect.GeneratedMethodAccessor139.invoke(Unknown Source) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25) at java.lang.reflect.Method.invoke(Method.java:589) at org.apache.tools.ant.dispatch.DispatchUtils.execute(DispatchUtils.java:106) at org.apache.tools.ant.Task.perform(Task.java:348) at org.apache.tools.ant.Target.execute(Target.java:390) at org.apache.tools.ant.Target.performTasks(Target.java:411) at org.apache.tools.ant.Project.executeSortedTargets(Project.java:1397) at org.apache.tools.ant.Project.executeTarget(Project.java:1366) at org.apache.tools.ant.helper.DefaultExecutor.executeTargets(DefaultExecutor.java:41) at org.apache.tools.ant.Project.executeTargets(Project.java:1249) at org.apache.tools.ant.module.bridge.impl.BridgeImpl.run(BridgeImpl.java:281) at org.apache.tools.ant.module.run.TargetExecutor.run(TargetExecutor.java:539) at org.netbeans.core.execution.RunClassThread.run(RunClassThread.java:154) BUILD FAILED (total time: 1 second)

    Read the article

  • Index Tuning for SSIS tasks

    - by Raj More
    I am loading tables in my warehouse using SSIS. Since my SSIS is slow, it seemed like a great idea to build indexes on the tables. There are no primary keys (and therefore, foreign keys), indexes (clustered or otherwise), constraints, on this warehouse. In other words, it is 100% efficiency free. We are going to put indexes based on usage - by analyzing new queries and current query performance. So, instead of doing it our old fashioned sweat and grunt way of actually reading the SQL statements and execution plans, I thought I'd put the shiny new Database Engine Tuning Advisor to use. I turned SQL logging off in my SSIS package and ran a "Tuning" trace, saved it to a table and analyzed the output in the Tuning Advisor. Most of the lookups are done as: exec sp_executesql N'SELECT [Active], [CompanyID], [CompanyName], [CompanyShortName], [CompanyTypeID], [HierarchyNodeID] FROM [dbo].[Company] WHERE ([CompanyID]=@P1) AND ([StartDateTime] IS NOT NULL AND [EndDateTime] IS NULL)',N'@P1 int',1 exec sp_executesql N'SELECT [Active], [CompanyID], [CompanyName], [CompanyShortName], [CompanyTypeID], [HierarchyNodeID] FROM [dbo].[Company] WHERE ([CompanyID]=@P1) AND ([StartDateTime] IS NOT NULL AND [EndDateTime] IS NULL)',N'@P1 int',2 exec sp_executesql N'SELECT [Active], [CompanyID], [CompanyName], [CompanyShortName], [CompanyTypeID], [HierarchyNodeID] FROM [dbo].[Company] WHERE ([CompanyID]=@P1) AND ([StartDateTime] IS NOT NULL AND [EndDateTime] IS NULL)',N'@P1 int',3 exec sp_executesql N'SELECT [Active], [CompanyID], [CompanyName], [CompanyShortName], [CompanyTypeID], [HierarchyNodeID] FROM [dbo].[Company] WHERE ([CompanyID]=@P1) AND ([StartDateTime] IS NOT NULL AND [EndDateTime] IS NULL)',N'@P1 int',4 and when analyzed, these statements have the reason "Event does not reference any tables". Huh? Does it not see the FROM dbo.Company??!! What is going on here? So, I have multiple questions: How do I get it to capture the actual statement executing in my trace, not what was submitted in a batch? Are there any best practices to follow for tuning performance related to SSIS packages running against SQL Server 2008?

    Read the article

  • Crystal report fails to load when application is deployed in IIS

    - by user1663380
    I copied the packageTmp over to the inetpub/wwwroot, then added a website and included it as my path installed the crystal report runtime,CRRuntime_32bit_13_0_4 but still did not work i also have crystalreportviewers13 folder in wwwroot/aspnet _client/systemweb/4_0_30319 this is the error I encountered when I go to the page with crystal report may i know where the path is defined? This problem occurs when I deploy my application in IIS. Exception Details: System.Runtime.InteropServices.COMException: Invalid file name. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [COMException (0x800001fb): Invalid file name.] CrystalDecisions.ReportAppServer.ClientDoc.ReportClientDocumentClass.Open(Object& DocumentPath, Int32 Options) +0 CrystalDecisions.ReportAppServer.ReportClientDocumentWrapper.Open(Object& DocumentPath, Int32 Options) +95 CrystalDecisions.ReportAppServer.ReportClientDocumentWrapper.EnsureDocumentIsOpened() +270 [CrystalReportsException: Load report failed.] CrystalDecisions.ReportAppServer.ReportClientDocumentWrapper.EnsureDocumentIsOpened() +333 CrystalDecisions.CrystalReports.Engine.ReportDocument.Load(String filename, OpenReportMethod openMethod, Int16 parentJob) +877 CrystalDecisions.CrystalReports.Engine.ReportClass.Load(String reportName, OpenReportMethod openMethod, Int16 parentJob) +1183 CrystalDecisions.CrystalReports.Engine.ReportDocument.EnsureLoadReport() +113 CrystalDecisions.CrystalReports.Engine.ReportDocument.SetDataSourceInternal(Object val, Type type) +53 CrystalDecisions.CrystalReports.Engine.ReportDocument.SetDataSource(DataTable dataTable) +66

    Read the article

  • Looking for best practise for writing a serial device communication app

    - by cdotlister
    I am pretty new to serial comms, but would like advise on how to best achieve a robust application which speak to and listens to a serial device. I have managed to make use of System.IO.SerialPort, and successfully connected to, sent data to and recieved from my device. The way things work is this. My application connects to the Com Port and opens the port.... I then connect my device to the com port, and it detects a connection to the PC, so sends a bit of text. it's really just copyright info, as well as the version of the firmware. I don't do anything with that, except display it in my 'activity' window. The device then waits. I can then query information, but sending a command such as 'QUERY PARAMETER1'. It then replies with something like: 'QUERY PARAMETER1\r\n\r\n76767\r\n\r\n' I then process that. I can then update it by sending 'SET PARAMETER1 12345', and it will reply with 'QUERY PARAMETER1\r\n\r\n12345\r\n\r\n'. All pretty basic. So, what I have done is created a Communication Class. this call is called in it's own thread, and sends data back to the main form... and also allows me to send messages to it. Sending data is easy. Recieving is a bit more tricky. I have employed the use of the datarecieved event, and when ever data comes in, I echo that to my screen. My problem is this: When I send a command, I feel I am being very dodgy in my handling. What I am doing is, lets say I am sending 'QUERY PARAMETER1'. I send the command to the device, I then put 'PARAMETER1' into a global variable, and I do a Thread.Sleep(100). On the data received, I then have a bit of logic that checks the incoming data, and sees if the string CONTAINS the value in the global variable. As the reply may be 'QUERY PARAMETER1\r\n\r\n76767\r\n\r\n', it sees that it contains my parameter, parses the string, and returns the value I am looking for, but placing it into another global variable. My sending method was sleeping for 100ms. It then wakes, and checks the returned global variable. If it has data... then I'm happy, and I process the data. Problem is... if the sleep is too short.. it will fail. And I feel it's flaky.. putting stuff into variables.. then waiting... The other option is to use ReadLine instead, but that's very blocking. So I remove the data received method, and instead... just send the data... then call ReadLine(). That may give me better results. There's no time, except when we connect initially, that data comes from the device, without me requesting it. So, maybe ReadLine will be simpler and safer? Is this known as 'Blocking' reads? Also, can I set a timeout? Hopefully someone can guide me.

    Read the article

  • How to parameterize a path in ANT?

    - by strelokstrelok
    I have the following defined in a file called build-dependencies.xml <?xml version="1.0" encoding="UTF-8"?> <project name="build-dependencies"> ... <path id="common-jars"> <fileset file="artifacts/project-1/jar/some*.jar" /> <fileset file="artifacts/project-2/jar/someother*.jar" /> </path> ... </project> I include it at the top of my build.xml file. Now I need to make the artifacts folder a parameter so it can be changed during execution of different targets. Having this... <?xml version="1.0" encoding="UTF-8"?> <project name="build-dependencies"> ... <path id="common-jars"> <fileset file="${artifacts}/project-1/jar/some*.jar" /> <fileset file="${artifacts}/project-2/jar/someother*.jar" /> </path> ... </project> ...and defining an "artifacts" property (and changing it) in the target does not work because it seems that the property substitution happens when the path is defined in build-dependencies.xml How can I solve this? One way I was thinking was to have a parameterized macro and call that before the path is actually used, but that seems not elegant. Something like this: <macrodef name="create-common-jars"> <attribute name="artifacts"/> <sequential> <path id="common-jars"> <fileset file="@{artifacts}/project-1/jar/some*.jar" /> <fileset file="@{artifacts}/project-2/jar/someother*.jar" /> </path> </sequential> </macrodef>

    Read the article

< Previous Page | 629 630 631 632 633 634 635 636 637 638 639 640  | Next Page >