Search Results

Search found 27142 results on 1086 pages for 'control structure'.

Page 720/1086 | < Previous Page | 716 717 718 719 720 721 722 723 724 725 726 727  | Next Page >

  • PacketFence Installation?

    - by Charles Miton
    So I've stumbled across PacketFence during my search for a decent Network Access Control system. After doing a little research about it's capabilities I've come to realize it's meets all the requirements that I was looking for. Unfortunately, being primarily a MS Administrator, I'm having many issues trying to successfully getting it up and running. Is there anyone or any place that has a step-by-step tutorial on how to do this? I love the prospect of using Open Source software, but need some help jumping this particular hurdle. I'm trying to use CentOS for the OS but I'm open to alternatives if thats what it takes to get this system up and running.

    Read the article

  • Asus z53 laptop overheating problem

    - by Tiberiu Hajas
    hi all, wondering if anyone encountered overheating of asus laptop ? especially the z53 model ? usually the right side of the laptop and vent in the upper corner is blowing hot air when under even minimal load, the CPU temperature can easily get to 65-70C and GPU is even above 80C. I'm using NHC (notebook health control) to set to a higher conservatory power consumption but that helps only a bit, anyone opened up the case ? wondering is require a dust clean ...etc ? I still have some warranty on it. thanks

    Read the article

  • 301 redirect from non www to www issue

    - by esmitex
    I have been trying to set a 301 redirect from a non www to a www domain since yesterday but it only cause problems on my site. I first tried it from the control panel of the website, then by modifying the .htaccess file with the following: Options +FollowSymlinks RewriteEngine on rewritecond %{http_host} ^mydomain.com [nc] rewriterule ^(.*)$ http://www.mydomain.com/$1 [r=301,nc] My site is based on wordpress, the first problem that occurred was that I could not access my backend anymore… when I was trying to log in the page would just reload itself and then there was an endless loop and the whole site was unaccessible. After removing these few lines, everything was fine.

    Read the article

  • Dye Sub printer with specific prints remaining - can I command-line query this?

    - by Jason N
    Hey, I've got a Sony Dye-Sub printer that holds ink/paper sets - i.e. a very certain amount of ink and paper for ~200 prints. This information is available to me from within Control Panel Printers Preferences Printer Device Information (i.e. current 189 remaining prints). Any way I can perhaps get this information from the command line? I'd like to write a little program to tell me when the number of prints gets low (i.e. < 20), rather than suffer the annoying Windows "run out of paper" popup. I've found the Windows VBScript print utilities, but can't seem to find the request I need for this. Any suggestions? Jason

    Read the article

  • How to add a permanent redirect (301) for an htm file in IIS 7

    - by bconlon
    Looking in Web Analytics I could see several external sites pointing at an old .htm file on my web server that no longer existed, so I thought I would get IIS to redirect to the new .aspx replacement. How hard could it be? This has annoyed me for quite a while today so here is the answer. 1. Install the Http Redirection module - this is not installed by default!! Windows 7 Start->Control Panel->Programs and Features->Turn Windows Features on or off. Internet Information Services->World Wide Web Services->Common Http Features->HTTP Redirection. Windows Server 2008 Start->Administrative Tools->Server Manager. Roles->Web Server (IIS). Role Services->Add Role Services. Common Http Features->HTTP Redirection. 2. Edit your web.config file <configuration>     .....     <location path="oldfile.htm">         <system.webServer>             <httpRedirect enabled="true" destination="/newfile.aspx" exactDestination="true" childOnly="true" httpResponseStatus="Permanent" />         </system.webServer>     </location>     ..... </configuration> When a user clicks or Google crawls ‘oldfile.htm’ it will get a permanent redirect to ‘/newfile.aspx’ - and should take any Page Rank to the new file.  #

    Read the article

  • What is causing a vm to exhibit packet loss?

    - by Joe Philllips
    We have a pretty nice piece of hardware set up to run multiple virtual machines in vmware and one of the vm's is an instance of Windows Server 2003 running SQL Server 2005. For some reason we occasionally see 10-20 seconds of straight packet loss to this machine from remote machines (my workstation) as well as other vm's on the same physical hardware. I am using PingPlotter to keep a close eye on the packet loss. So far we've turned off flow control on the NIC but we are already running out of other things to try. What might be causing this and how can I identify the problem? Note: We also have another server with a very similar configuration with the same type of problem to a lesser extent (because its not used as heavily?)

    Read the article

  • Cannot authenticate a domain user with SQL Server 2008

    - by Sambo
    I'm new to setting up Domains so I might be missing something simple here... I've installed SQL Server 2008 on a Windows Server 2008 R2 box and I have another WS2008 R2 box acting as the domain controller. I've joined the SQL server to the domain and it seems to be behaving itself fine. I can ping the DC by name and IP address. I created a domain user 'SPSQLAdmin' that I want to use for database access with SharePoint but I can't seem to log on to SQL with this user. SQL complains, saying that the user belongs to an untrusted domain. I've configured the DC to delegate control for any service to the SQL Server but it doesn't improve the situation. What should I try next? Thanks in advance.

    Read the article

  • Windows 2003 Server on a domain, XP client PCs on a workgroup - file share without authentication?

    - by Zach
    I have a windows 2003 server on a domain and client PCs running XP on a workgroup. I have created a file share on the server that should be accessible by the client PCs. I even set the security and sharing to 'Everyone' just to test. When I try to access the file share from any of the XP machines, I get an authentication prompt that displays asking for credentials, even though 'Everyone' has full control currently (just for testing purposes). Why is it asking to authenticate? I need it to where it doesn't ask to authenticate. I also made sure passwords were set on all XP machines since I found this could be one possible issue and they all were. Any ideas? Thanks!

    Read the article

  • Microsoft Outlook tips and tricks for improving user experience?

    - by Roee Adler
    I'm one of those heavy Microsoft Outlook users, currently working on the 2007 version. God knows this tool is heavy and may impose problems. I wondered what the Super User crowd has to suggest in order to improve the usage experience. Several suggestions of my own: Always work in cached mode (Tools--Account Settings--Change--Use Cached Exchange Mode) Use Outlook's local archiving capabilities Use Outlook's RSS reader - it's simple and allows offline access to your feeds If you have e-mail subscriptions to magazines, blogs, etc. - create a subdirectory to keep them, and a rule to automatically move them there when they arrive (one rule per subscription, based on the sender e-mail.) You can also share suggestions that require configuration of Exchange Server, for those of us who can make bring them to their IT managers. What are your suggestions? PS: "Use Gmail" is not an accepted answer, some of us don't control what email system we use...

    Read the article

  • Why does 301 redirect work for http but not for https?

    - by Tom G
    Through my domain registrar I have set up a domain, essayme.co.uk, to automatically forward to https://google.com. If I go to http://essayme.co.uk it works as expected and redirects me to https://google.com. $curl -i http://essayme.co.uk HTTP/1.1 301 Moved Permanently Cache-Control: max-age=900 Content-Type: text/html Location: https://google.com Server: Microsoft-IIS/7.5 X-AspNet-Version: 4.0.30319 X-Powered-By: ASP.NET Date: Sat, 07 Jun 2014 11:14:16 GMT Content-Length: 0 Age: 0 Connection: keep-alive However, if I go to https://essayme.co.uk it just freezes and times out. $curl -i https://essayme.co.uk curl: (7) Failed connect to essayme.co.uk:443; Operation timed out What is happening in the second case? (and, if possible, how can I get the redirect to work for https?) Problem background/clarification: I don't have an SSL certificate for the essayme.co.uk domain above, but I do for my live domain (let's call it mywebsite.com), and I was seeing the exact same problem on this domain (hence why I'm trying to debug the problem). Unfortunately I can't experiment with the live domain (as it's live) and I would like to avoid having to buy a second certificate for essayme.co.uk just for debugging (unless absolutely necessary). The problem I was seeing: my live domain, mywebsite.com (not its real name), has a valid SSL certificate. Visiting https://www.mywebsite.com displayed the webpage as expected. I had set up forwarding (like in the question above) from the naked domain (mywebsite.com) to https://www.mywebsite.com) Visiting http://mywebsite.com redirected to https://www.mywebsite.com as expected. However, visiting https://mywebsite.com would freeze and time out (as in the question above). I also tried forwarding it to http://www.otherwebsite.com as an experiment (i.e. forwarding to another site that does not use SSL), but the result was the same: Visiting http://mywebsite.com redirected to http://www.otherwebsite.com as expected. Visiting https://mywebsite.com would freeze and time out again. So I set up essayme.co.uk as an experiment to try and understand why it doesn't work.

    Read the article

  • How to create an GUI that communicate with the USB Devices

    - by VINAYAK
    I am doing my Project using win 32 programming.I am just learning about win32 programming and able to create an UI.I want to communicate with an USB Device with that UI.SO,How can i go for that?Is there any predefined functions will be there are we need to create the function for communicating with the OS and get the devices List and got the details about them. My purpose is to , 1.Creating an UI that tells about the Basic information about the device(We want to send a control request to the device to get the descriptors). 2.For that first of all i want to communicate with the OS for device attachment.That will lead to get the information about the device and Enumeration takes place and then only i request the device information through descriptors by using standard Requests. 3.And also i want to create the driver for my device.That will also need to achieve for communicating with OS(Windows). So,can anyone help me about this?How can i achieve this or approach this? Note: I am at the entry level now so anyone give response will be in a detailed format like step by step process would be appreciable.

    Read the article

  • Financial institutions build predictive models using Oracle R Enterprise to speed model deployment

    - by Mark Hornick
    See the Oracle press release, Financial Institutions Leverage Metadata Driven Modeling Capability Built on the Oracle R Enterprise Platform to Accelerate Model Deployment and Streamline Governance for a description where a "unified environment for analytics data management and model lifecycle management brings the power and flexibility of the open source R statistical platform, delivered via the in-database Oracle R Enterprise engine to support open standards compliance." Through its integration with Oracle R Enterprise, Oracle Financial Services Analytical Applications provides "productivity, management, and governance benefits to financial institutions, including the ability to: Centrally manage and control models in a single, enterprise model repository, allowing for consistent management and application of security and IT governance policies across enterprise assets Reuse models and rapidly integrate with applications by exposing models as services Accelerate development with seeded models and common modeling and statistical techniques available out-of-the-box Cut risk and speed model deployment by testing and tuning models with production data while working within a safe sandbox Support compliance with regulatory requirements by carrying out comprehensive stress testing, which captures the effects of adverse risk events that are not estimated by standard statistical and business models. This approach supplements the modeling process and supports compliance with the Pillar I and the Internal Capital Adequacy Assessment Process stress testing requirements of the Basel II Accord Improve performance by deploying and running models co-resident with data. Oracle R Enterprise engines run in database, virtually eliminating the need to move data to and from client machines, thereby reducing latency and improving security"

    Read the article

  • how to get the update manager window visible?

    - by Max Waterman
    I can see from the launcher that the Update Manager is running - it has the little triangle by it. However, I am having trouble seeing the window. If I click on it from one desktop, it switches to another, so I assume that the Update Manager has its window on that other desktop, but it still doesn't show anything. If I click alt-tab to switch between apps, I can see that the Update Manager is there, but selecting it just shows me a blank screen. Also, when I select it, while still holding the alt-key, I see the top menu bar switch to 'Update Manager', but when I release alt, it changes back to Ubuntu Desktop. It's almost like the app is off the screen somewhere, perhaps with just a single pixel showing or something like that. disclaimer: One thing that might be affecting things is that I have 'focus follows mouse' configured, which makes things a bit funky with the menu not being on the window, where it should be (perhaps there's a way to put it back with the window?) - I like to be able to type into background windows, and manually control which window is in the foreground.

    Read the article

  • Macbook Pro + Windows 7 (bootcamp) = Terrible battery life

    - by Scott Beeson
    I recently put Windows 7 Ultimate x64 on my wife's Macbook pro because of some software she bought for her business. Since then, the battery life has been abysmal. I've identified and researched one of the problems, which is display brightness. There is no brightness control in the windows power options, but I did manually turn it down in Bootcamp. However, it is still reporting very low battery life estimates. I'm wondering if this is because Windows thinks the display is at full brightness. Can anyone shed any light on this? (Pun intended). Also, are there any other things to look out for that may improve the battery life? (I mean in the context of Mac + Windows, not in general)

    Read the article

  • Importing tab delimited file into array in Visual Basic 2013 [migrated]

    - by JaceG
    I am needing to import a tab delimited text file that has 11 columns and an unknown number of rows (always minimum 3 rows). I would like to import this text file as an array and be able to call data from it as needed, throughout my project. And then, to make things more difficult, I need to replace items in the array, and even add more rows to it as the project goes on (all at runtime). Hopefully someone can suggest code corrections or useful methods. I'm hoping to use something like the array style sMyStrings(3,2), which I believe would be the easiest way to control my data. Any help is gladly appreciated, and worthy of a slab of beer. Here's the coding I have so far: Imports System.IO Imports Microsoft.VisualBasic.FileIO Public Class Main Dim strReadLine As String Private Sub Form1_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load Dim sReader As IO.StreamReader = Nothing Dim sRawString As String = Nothing Dim sMyStrings() As String = Nothing Dim intCount As Integer = -1 Dim intFullLoop As Integer = 0 If IO.File.Exists("C:\MyProject\Hardware.txt") Then ' Make sure the file exists sReader = New IO.StreamReader("C:\MyProject\Hardware.txt") Else MsgBox("File doesn't exist.", MsgBoxStyle.Critical, "Error") End End If Do While sReader.Peek >= 0 ' Make sure you can read beyond the current position sRawString = sReader.ReadLine() ' Read the current line sMyStrings = sRawString.Split(New Char() {Chr(9)}) ' Separate values and store in a string array For Each s As String In sMyStrings ' Loop through the string array intCount = intCount + 1 ' Increment If TextBox1.Text <> "" Then TextBox1.Text = TextBox1.Text & vbCrLf ' Add line feed TextBox1.Text = TextBox1.Text & s ' Add line to debug textbox If intFullLoop > 14 And intCount > -1 And CBool((intCount - 0) / 11 Mod 0) Then cmbSelectHinge.Items.Add(sMyStrings(intCount)) End If Next intCount = -1 intFullLoop = intFullLoop + 1 Loop End Sub

    Read the article

  • Syncing client and server CRUD operations using json and php

    - by Justin
    I'm working on some code to sync the state of models between client (being a javascript application) and server. Often I end up writing redundant code to track the client and server objects so I can map the client supplied data to the server models. Below is some code I am thinking about implementing to help. What I don't like about the below code is that this method won't handle nested relationships very well, I would have to create multiple object trackers. One work around is for each server model after creating or loading, simply do $model->clientId = $clientId; IMO this is a nasty hack and I want to avoid it. Adding a setCientId method to all my model object would be another way to make it less hacky, but this seems like overkill to me. Really clientIds are only good for inserting/updating data in some scenarios. I could go with a decorator pattern but auto generating a proxy class seems a bit involved. I could use a generic proxy class that uses a __call function to allow for original object data to be accessed, but this seems wrong too. Any thoughts or comments? $clientData = '[{name: "Bob", action: "update", id: 1, clientId: 200}, {name:"Susan", action:"create", clientId: 131} ]'; $jsonObjs = json_decode($clientData); $objectTracker = new ObjectTracker(); $objectTracker->trackClientObjs($jsonObjs); $query = $this->em->createQuery("SELECT x FROM Application_Model_User x WHERE x.id IN (:ids)"); $query->setParameters("ids",$objectTracker->getClientSpecifiedServerIds()); $models = $query->getResults(); //Apply client data to server model foreach ($models as $model) { $clientModel = $objectTracker->getClientJsonObj($model->getId()); ... } //Create new models and persist foreach($objectTracker->getNewClientObjs() as $newClientObj) { $model = new Application_Model_User(); .... $em->persist($model); $objectTracker->trackServerObj($model); } $em->flush(); $resourceResponse = $objectTracker->createResourceResponse(); //Id mappings will be an associtave array representing server id resources with client side // id. //This method Dosen't seem to flexible if we want to return additional data with each resource... //Would have to modify the returned data structure, seems like tight coupling... //Ex return value: //[{clientId: 200, id:1} , {clientId: 131, id: 33}];

    Read the article

  • Multi monitor windows positioning problem

    - by Peter Stegnar
    I need a good multi monitor tool mainly to gain control over the windows positioning. I have problem that closed window/application remembers at which monitors it was (closed). I have disconnect this monitor (this is often LCD TV) I have problem with this "remembering" windows/applications that was closed in LCD TV are out of sight when LCD TV is disconnected. What is the best practice to deal with this problem other that that not to close windows on this monitor)? Are there any good multi-monitor software to deal with this?

    Read the article

  • How do you make Windows 7 fully case-sensitive with respect to the filesystem?

    - by trusktr
    I want to make Windows 7 case-sensitive when it reads/writes anything on the hard drive (the C drive, or any other NTFS drive). I found a video via google that says to change the registry key HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Explorer\Advanced\DontPrettyPath to a value of 1 (source). I also found a Windows support item that says something about modifying the registry key HKLM\SYSTEM\CurrentControlSet\Control\Session Manager\kernel\obcaseinsensitive that leads me to assume putting a value of 0 will make Windows case-sensitive with NTFS filesystems (source). I have a feeling the second solution is the answer, but I'm not sure and I don't want to try it without being sure. Does anyone know for sure what is the correct way to make Windows 7 case-sensitive when it reads/writes to the C drive (and any other NTFS drive)?

    Read the article

  • How to Restart Windows Update Service in Windows 7?

    - by N.O.R.G.
    I'm running into an issue with Windows Update on Windows 7 Professional. I am totally up to date in Windows Updates as of last week, but discovered this issue [today] during my Sunday morning PC maintenance ritual. In CONTROL PANEL - SYSTEM & SECURITY - Windows Update, when I select "Check for Updates", I get a pop-up stating: "Windows Update cannot currently check for updates, because the service is not running. You may need to restart your computer." I've re-started several times, checked that the service hadn't been disabled at start up, and I've googled extensively on the topic - but have come up with nothing. I know there must be some way to start the service from the cmd line, and I would like to know how to get the service to start at boot. Please let me know if I have left any details out that may aid in formulating a response. Any of the community's excellent insights would be greatly appreciated!

    Read the article

  • Is it possible to tunnel ICMP over TCP?

    - by Robert Atkins
    I don't want to tunnel TCP over ICMP (as ptunnel does), I want to go the other way around. I'm in the situation where I have TCP (HTTP) connectivity to a machine but an internal firewall over which I have no control is swallowing pings. The monitoring software I'm using appears to determine connectivity by attempting to send a ping before it tries to just connect to the web service on the target machine. It's failing this ping test and giving up. I believe if I could fool my monitoring software into thinking pings were getting through, it would then connect to the web service and be on its merry way. Anyone know how I can do this? I have SSH and root access on the destination machine.

    Read the article

  • Ganglia divide colors by rolles

    - by com
    Sorry for a silly question I am still newbie to Ganglia. In Ganglia I control few important metrics for mysql (seconds behind master and etc.). In addition I have few bunches of mysql servers (every bunch has it's own tasks, but all of the bunches should be tested for seconds behind master). I am interested if this possible to show all metrics on the one page with different colors to different bunches. Right now in metric "seconds behind master" I see all mysql servers with metric "seconds behind master" with colors to different states (red is critical, gray is ok). Can I set a color to a graph according to it's bunch? Thanks!

    Read the article

  • Laptop VGA Out Stopped Working

    - by Jack7890
    I regularly use an external monitor with my laptop. Today, when I booted up, the external monitor refused to work--it just keeps going into power save mode. I tried a different external monitor and had the same problem, so it must be a problem with the laptop itself. Things I've tried: Going into the Display Settings via the Control Panel (I'm running Vista) and attaching/unattaching/reattaching the external monitor. Turning the computer off, unplugging, plugging it back in, and rebooting Blowing into the VGA out to get rid of any dust Toggling through the Fn+F7 options I'm thinking maybe this is an issue with my video card? If necessary, I'm comfortable opening up my laptop and playing around with things, but I'm not sure what to look for. Does anyone have any suggestions?

    Read the article

  • Hot Off the Press - Oracle Exadata: A Data Management Tipping Point

    - by kimberly.billings
    Advances in data-management architecture - including CPU, memory, storage, I/O, and the database - have been steady but piecemeal. In this report, Merv Adrian describes how Oracle Exadata not only provides the latest technology in each part of the data-management architecture, but also integrates them under the full control of one vendor with a unified approach to leveraging the full stack. He writes, "the real "secret sauce" of Oracle Exadata V2 is the way in which these technologies complement each other to deliver additional performance and scalability." Merv interviews two Exadata customers, Banco Transylvania and TUI Netherlands, and concludes that early indications are that Oracle Exadata is delivering on its promise of extreme performance and scalability. His recommendation to IT is to target corporate applications with the biggest potential for speed-based enhancement, and consider whether Oracle Exadata V2 can cost-effectively enable new ways to use these for competitive advantage. Read the full report. var gaJsHost = (("https:" == document.location.protocol) ? "https://ssl." : "http://www."); document.write(unescape("%3Cscript src='" + gaJsHost + "google-analytics.com/ga.js' type='text/javascript'%3E%3C/script%3E")); try { var pageTracker = _gat._getTracker("UA-13185312-1"); pageTracker._trackPageview(); } catch(err) {}

    Read the article

  • How likely can my data be recovered after Windows CHKDSK performed on a degraded RAID 5 array?

    - by chrisling106
    Hello there, We have a RAID 5 setup with 3 SATA disks, #2 went down as reported on the pre-POST screen. Unfortunately, for some reason out of my control, the system was rebooted with a degraded RAID :-O Windows XP (64-bit) loaded, CHKDSK ran automatically and done its recovery! From that point onwards, the following error prompts every time even in Safe Mode: lsass.exe - The endpoint format is invalid I took those 3 disks to the data recovery expert and need to wait at least 2-4 days for results. There are 2 VMs on multiple files stored in this RAID 5 array, and there's no backup! Sorry, I just inherited the system from an ex-staff who has left the company 2 months before I joined. How likely the data can be recovered?

    Read the article

  • Transparently cache files from a network drive in Linux

    - by Vadim
    We have a Linux server that reads files from a network drive and processes them. In a common scenario, a user will log in and access the same files over and over again. The size of the files varies but the larger ones can be around 50+ Mb. The files seldom change. I was wondering if it's somehow possible to transparently cache the files. I don't want (or can) change the program the reads the files, nor do I control the protocol by which the files are accessed. I just want something to detect that I access a certain path, copy the file locally (if needed) and then read the file from the local drive. I've read about Bcache but can't figure out if it's what I need. Do you have any suggestions? Thanks, Vadim.

    Read the article

< Previous Page | 716 717 718 719 720 721 722 723 724 725 726 727  | Next Page >