Search Results

Search found 21965 results on 879 pages for 'array map'.

Page 754/879 | < Previous Page | 750 751 752 753 754 755 756 757 758 759 760 761  | Next Page >

  • SATA drives or chipset throwing DRDY ERR and ICRC ABRT

    - by Matt
    I have an SD-VIA-1A2S PCI card with 2 sata ports (and one ATA-133 that isn't used). Two new Western Digital Caviar Green drives (WD10EARS 1TB) throw repeated errors in kern.log (removed date/time/host info for brevity): [ 7.376475] ata2.00: exception Emask 0x12 SAct 0x0 SErr 0x1000500 action 0x6 [ 7.376480] ata2.00: BMDMA stat 0x5 [ 7.376483] ata2: SError: { UnrecovData Proto TrStaTrns } [ 7.376489] ata2.00: cmd c8/00:40:20:00:00/00:00:00:00:00/e0 tag 0 dma 32768 in [ 7.376490] res 51/84:2f:20:00:00/00:00:00:00:00/e0 Emask 0x12 (ATA bus error) [ 7.376493] ata2.00: status: { DRDY ERR } [ 7.376495] ata2.00: error: { ICRC ABRT } [ 7.376504] ata2: hard resetting link I'm using Ubuntu 9.04 - 2.6.28-18-generic, though I have tried live cds of Ubuntu 9.10, Fedora 12 and OpenSUSE 11.2 - all running various 2.6.31 kernels - and all received the same error. Based on testing these drives and this card in two other machines and combos of connecting the drives directly to the motherboard or the add-in card, I'm relatively convinced that it's the VIA chipset that is the problem. Another computer that also has an onboard VIA SATA chipset (like the add-in card) produces the same errors when the drives are directly on that motherboard. I have been able to verify that the drives are perfectly good, and I tried everything I can think of in terms of swapping cables, psu isn't overloaded, etc. The error happens on boot once or twice, after using fdisk on the drive once or twice, and constantly when attempting to sync a new mdadm raid 1 array created on the two drives. Any thoughts on where to go from here - driver/kernel wise? I'm completely open to buying a new PCI add-in card if someone can recommend one with 2 internal sata ports that works well in Debian/Ubuntu. Thanks!

    Read the article

  • Move database from SQL Server 2012 to 2008

    - by Rich
    I have a database on a SQL Sever 2012 instance which I would like to copy to a 2008 server. The 2008 server cannot restore backups created by a 2012 server (I have tried). I cannot find any options in 2012 to create a 2008 compatible backup. Am I missing something? Is there an easy way to export the schema and data to a version-agnostic format which I can then import into 2008? The database does not use any 2012 specific features. It contains tables, data and stored procedures. Here is what I have tried so far: I tried "tasks" - "generate scripts" on the 2012 server, and I was able to generate the schema (including stored procedures) as a sql script. This didn't include any of the data, though. After creating that schema on my 2008 machine, I was able to open the "Export Data" wizard on the 2012 machine, and after configuring the 2012 as source machine and the 2008 as target machine, I was presented with a list of tables which I could copy. I selected all my tables (300+), and clicked through the wizard. Unfortunately it spends ages generating its scripts, then fails with errors like "Failure inserting into the read-only column 'FOO_ID'". I also tried the "Copy Database Wizard", which claimed to be able to copy "from 2000 or later to 2005 or later". It has two modes: 1) "detach and attach", which failed with error: Message: Index was outside the bounds of the array. StackTrace: at Microsoft.SqlServer.Management.Smo.PropertyBag.SetValue(Int32 index, Object value) ... at Microsoft.SqlServer.Management.Smo.DataFile.get_FileName() 2) SQL Management Object Method which failed with error "Cannot read property IsFileStream.This property is not available on SQL Server 7.0."

    Read the article

  • RAID 5 - DELL 2850 and others

    - by Kiara
    I have installed Ubuntu on a DELL 2850 and I have configured an array of 5 disks (SCSI 73GB 10K) in RAID5. I wanted to simulate a drive error so in the middle of something I just took one of the drives out and put it back again after a bit. Then the drive shows an orange light and seems to be rebuilding but actually is taking hours and hours with no results. So I went to the PERC utility (Ctrl+M) and the disk shows "REBLD". But it never gets to an online state. So I went to Objects - Physical drives - Rebuilding - View rebuild process. And in here I can see a bar moving from 0%... but if I reboot before finishing and get into the PERC Utility again, it seems to start again rebuilding from 0% - so it is not rebuilding automatically. My concern is: what would happen in a real situation? Do I have to just switch the server off and go to the Perc utility to start the rebuilding manually? I thought the whole point was to have this done automatically and without the need of stopping the server. Or does it perhaps rebuild automatically indeed but needs to have enough time without rebooting because otherwise the rebuilding process will start from scratch? It seems to take more than 3h for a 73gb disk! My second question is: can I mix then hard drives? So if I have a RAID of 5x73GB 10K can I use different size (146GB) or speeds (15K)? Apparently someone said it is OK in here Poweredge 2850: replace disk with larger in RAID?

    Read the article

  • Communication software wanted: email, sms, IM, phone calls [closed]

    - by user63835
    I am searching for a software solution that integrates / unifies my communication. I use email, instant messaging, SMS and phone. I would like to get all emails, SMS, instant messaging dialogs and meta-data about phone calls into one application. Important is that I can access all past communication with one application. There should be a global address-book to map the communication data to persons or organizations. I want all the communication data in one place to access and backup it easily. The software solution is not required to be multi-user application or server application. It is just for one user (me) only, but server or multi-user applications are not excluded. I may run it on a server hardware. It should run on Linux (Lubuntu / Ubuntu prefered). Free and OpenSource software is prefered. It would be nice if I could perform new communication (like writing a new email, sms, etc.) with one application, but that is not a must have requirement. I could also work with different applications dedicated for different types of communication like IM-application for IM and email-application for email, if all that communication data from the specialized applications will be delivered to one single place where I can access and backup it. I have an android phone and currently I am using Google contacts as the address-book. In the long term this may change, to get back the control over my data. I did some Internet search but did not find a nice solution, yet. If I am looking for unified messaging and unified communication, am I on the right track? The current Thunderbird version has IM functionality integrated. Did not try it, yet. For SMS it may be possible to use an app to send every SMS (incoming and outgoing) as an email, but I am not sure if those SMS-emails can be mapped to an address-book contact. I don't remember exactly, but isn't there a Google android app (I think Google voice) integrating SMS into google services? But in Germany this function has not been released, yet. Maybe a groupware solution would solve the requirements, but I don't have much experience with it. As communication possibilites are groing, I am woundering that there seems to be such a big gap of solutions. I can't believe I am the only one who would like solution, better integrating all the communication channels more easily. If you know a software solution that solves these requirements (partly) I would be glad if you tell me about it. Thanks in advance.

    Read the article

  • Rails 3 shows 404 error instead of index.html (nginx + unicorn)

    - by Miko
    I have an index.html in public/ that should be loading by default but instead I get a 404 error when I try to access http://example.com/ The page you were looking for doesn't exist. You may have mistyped the address or the page may have moved. This has something to do with nginx and unicorn which I am using to power Rails 3 When take unicorn out of the nginx configuration file, the problem goes away and index.html loads just fine. Here is my nginx configuration file: upstream unicorn { server unix:/tmp/.sock fail_timeout=0; } server { server_name example.com; root /www/example.com/current/public; index index.html; keepalive_timeout 5; location / { try_files $uri @unicorn; } location @unicorn { proxy_pass http://unicorn; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $host; proxy_redirect off; } } My config/routes.rb is pretty much empty: Advertise::Application.routes.draw do |map| resources :users end The index.html file is located in public/index.html and it loads fine if I request it directly: http://example.com/index.html To reiterate, when I remove all references to unicorn from the nginx conf, index.html loads without any problems, I have a hard time understanding why this occurs because nginx should be trying to load that file on its own by default. -- Here is the error stack from production.log: Started GET "/" for 68.107.80.21 at 2010-08-08 12:06:29 -0700 Processing by HomeController#index as HTML Completed in 1ms ActionView::MissingTemplate (Missing template home/index with {:handlers=>[:erb, :rjs, :builder, :rhtml, :rxml, :haml], :formats=>[:html], :locale=>[:en, :en]} in view paths "/www/example.com/releases/20100808170224/app/views", "/www/example.com/releases/20100808170224/vendor/plugins/paperclip/app/views", "/www/example.com/releases/20100808170224/vendor/plugins/haml/app/views"): /usr/local/rvm/gems/ruby-1.9.2-rc2/gems/actionpack-3.0.0.beta4/lib/action_view/paths.rb:14:in `find' /usr/local/rvm/gems/ruby-1.9.2-rc2/gems/actionpack-3.0.0.beta4/lib/action_view/lookup_context.rb:79:in `find' /usr/local/rvm/gems/ruby-1.9.2-rc2/gems/actionpack-3.0.0.beta4/lib/action_view/base.rb:186:in `find_template' /usr/local/rvm/gems/ruby-1.9.2-rc2/gems/actionpack-3.0.0.beta4/lib/action_view/render/rendering.rb:45:in `_determine_template' /usr/local/rvm/gems/ruby-1.9.2-rc2/gems/actionpack-3.0.0.beta4/lib/action_view/render/rendering.rb:23:in `render' /usr/local/rvm/gems/ruby-1.9.2-rc2/gems/haml-3.0.15/lib/haml/helpers/action_view_mods.rb:13:in `render_with_haml' etc... -- nginx error log for this virtualhost comes up empty: 2010/08/08 12:40:22 [info] 3118#0: *1 client 68.107.80.21 closed keepalive connection My guess is unicorn is intercepting the request to index.html before nginx gets to process it.

    Read the article

  • Outbound HTTP performance tuning recommendations

    - by Richard Gadsden
    I'll detail my exact setup below, but general recommendations for a better web-browsing experience will be useful. A nice checklist of things to try would be great! I have 600 users on a single site with an 8MB leased line. I get a lot of moans about the performance of "the internet" (ie web-browsing). What recommendations do the community have for speeding things up without just throwing more bandwidth at it? I expect I will end up buying some more, but good management tips are always valuable. My setup is this: Cisco PIX (515E) firewall on the edge of the network. It's just doing some basic NAT, and opening up a handful of ports to various bastion hosts (aka DMZ servers). The DMZ is just a switch that the servers are plugged into. ISA 2006 Enterprise array (two servers) connecting DMZ to the internal LAN, with WebSense Web Security filtering HTTP traffic so users can't look at porn or waste bandwidth on YouTube during working hours. I've done a few things - I've just switched my internal DNS over to use root hints, which halved DNS query latency from 500ms to 250ms. Well worth doing. I'm trying to cache more aggressively, but so much more of the internet is AJAXy and doesn't cache very well as compared to five years ago. Plus the 70GB of cache which felt like a lot a few years ago really isn't any more. I'm getting about 45% cache hits by number of requests, but only about 22% by size, ie larger objects are less likely to be cached. Latency seems to be part of the problem. Is that attributable to the bandwidth problem, or are there things I can look at to try to reduce latency even on heavily-loaded bandwidth?

    Read the article

  • JAWStats statspath error on windows

    - by crosenblum
    I have AWStats which works fine, and JAWStats I am trying to get working. I have tried back and forward slashes to get the program to read the dirdata files. I even moved the folder of dirdata outside of program files folder, in case it had problems with folder names with spaces in them. Here is my config file. // core config parameters $sConfigDefaultView = "thismonth.all"; $bConfigChangeSites = true; $bConfigUpdateSites = true; $sUpdateSiteFilename = "xml_update.php"; // individual site configuration // awstats092012.noname.jumpingcrab.com.txt $aConfig["site1"] = array( "statspath" => "C:\\Program Files\\AWStats\\DirData\\", "statsname" => "awstats[MM][YYYY].yourexample.com.txt", "updatepath" => "C:\\Program Files\\AWStats\\wwwroot\\cgi-bin\\awstats.pl\\", "siteurl" => "http://yourexample.com", "theme" => "default", "fadespeed" => 250, "password" => "", "includes" => "" ); Domain names changed to protect the innocent...:P Here is the error message: An error has occured: No AWStats Log Files Found JAWStats cannot find any AWStats log files in the specified directory: C:\Program Files\AWStats\DirData\ Is this the correct folder? Is your config name, site1, correct? Please refer to the installation instructions for more information.

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here. EDIT: I found another person who has the exact same problem as me: http://www.ibm.com/developerworks/forums/thread.jspa?messageID=14451763

    Read the article

  • NVidia ION and /dev/mapper/nvidia_... issues.

    - by Ritsaert Hornstra
    I have an NVidia ION board with 4 SATA ports and want to use that to run a Linux Server (CentOS 5.4). I first hooed up 3 HDs (that will be a RAID5 array) and a forth small boot HD. I first started to use the onboard RAID capability but that does not work correctly under Linux: the raid capacity is not a real RAID but uses lvm to define some arays. After setting the BIOS back to normal SATA mode and whiping the HDs, the first boot harddisk (/dev/sda) is seen as /dev/sda BEFORE mounting and after mounting as /dev/mapper/nvidia_. CentOS is unable to install on it (and grub is not installable on it either). So somehow the harddisk is still seen as if it belongs to some lvm volume. I tried to clean out the HD by issuing a few dd if=/dev/zero of=/dev/sda commands to wipe the starting cylinders and final cylinders but to no avail. Did anyone see this problem and did anyone find a solution? UPDATE When I create only a single ext3 partition on the first HD (/dev/mapper/nvidia_...) no LVM partitions are seen and I can boot from /dev/mapper/nvidia_.... Now the next step is to see how I can get rid of this folly.

    Read the article

  • Sendmail relay authentication

    - by Pawel Veselov
    I'm trying to set up my sendmail to authenticate against a relay (comcast). I'm not seeing any attempts to authenticate at all. I'm trying to just debug how authentication works, and can't connect all the pieces... I have, in my .mc file: define(`RELAY_MAILER_ARGS', `TCP $h 587')dnl define(`SMART_HOST', `relay:smtp.comcast.net.')dnl define(`confAUTH_MECHANISMS', `PLAIN')dnl FEATURE(`authinfo',`hash /etc/mail/client-info')dnl And in my /etc/mail/client-info: AuthInfo:*.comcast.net "U:root" "I:comcast_user" "P:comcast_password" Now, I know everything is fine with the u/p, as I could authenticate directly through SMTP, using telnet. There are two things I don't understand. When AuthInfo records are searched for, they are matched by the target hostname. How? Does it it use the map key (something I would expect), or uses the so-called "Domain" ("R:" parameter that I don't set in my auth-info line) What is "U:", really? Sendmail README (http://www.sendmail.org/m4/smtp_auth.html) says it's "user(authoraztion id)", and "I:" is "authentication ID". That suggests that my username should be in "U:", actually, but http://www.sendmail.org/~ca/email/auth.html says that "I:" is your remote user name. The session looks like this: [root@manticore]/etc/mail# sendmail -qf -v Warning: Option: AuthMechanisms requires SASL support (-DSASL) Running /var/spool/mqueue/p97CgcWq023273 (sequence 1 of 399) [email protected]... Connecting to smtp.comcast.net. port 587 via relay... 220 omta19.westchester.pa.mail.comcast.net comcast ESMTP server ready >>> EHLO my.host.name 250-omta19.westchester.pa.mail.comcast.net hello [my.ip.add.res], pleased to meet you 250-HELP 250-AUTH LOGIN PLAIN 250-SIZE 15728640 250-ENHANCEDSTATUSCODES 250-8BITMIME 250-STARTTLS 250 OK >>> STARTTLS 220 2.0.0 Ready to start TLS >>> EHLO my.host.name 250-omta19.westchester.pa.mail.comcast.net hello [my.ip.add.res], pleased to meet you 250-HELP 250-AUTH LOGIN PLAIN 250-SIZE 15728640 250-ENHANCEDSTATUSCODES 250-8BITMIME 250 OK >>> MAIL From:<> SIZE=2183 550 5.1.0 Authentication required MAILER-DAEMON... aliased to postmaster postmaster... aliased to root root... aliased to [email protected] postmaster... aliased to root root... aliased to [email protected] >>> RSET 250 2.0.0 OK [root@manticore]/etc/mail# sendmail -d0.1 Version 8.14.3 Compiled with: DNSMAP LOG MAP_REGEX MATCHGECOS MILTER MIME7TO8 MIME8TO7 NAMED_BIND NETINET NETINET6 NETUNIX NEWDB NIS PIPELINING SCANF SOCKETMAP STARTTLS TCPWRAPPERS USERDB XDEBUG Thanks, Pawel.

    Read the article

  • Are HDMI to VGA Adapters Really Device-Specific?

    - by allquixotic
    There are a lot of devices on the market right now (especially mobile devices) with a Micro-HDMI or Mini-HDMI port and no VGA or D-Sub output. Most manufacturers of said devices sell a cable that looks something like this: I have yet to find a cable like this that claims to work on a wide array of devices. In general, these cables claim to work with one specific device only. The way these cables work, I think, is that analog VGA signals are sent from the HDMI port on the device. This should work for devices that have special hardware on the motherboard/GPU capable of driving this. Is it the case that these cables have to be custom designed for each device? Or, is it rather that any device which possesses this special "signaling of analog VGA over the HDMI port" can be made to work with a cable that is physically compatible (i.e. the HDMI end plugs into the device and the VGA end accepts a VGA monitor cable)? Note that I am not looking for a product recommendation, just a conceptual clarification on what exactly these devices are doing. Also, a few remarks: The cables like the one depicted here are not digital to analog converters. I know about these: they are expensive, and they are the ONLY solution if your device only outputs a digital signal and is incapable of driving analog VGA over the HDMI port. The cables like the one depicted here are not straight crossover cables from VGA to HDMI, either. The crossover cables are designed to send a digital HDMI signal over the VGA port's wires; that is, the wire protocol is HDMI (digital) but the physical pinout is the same as VGA, even though nothing analog is happening. Once again, this is not the behavior that, I believe, the devices which I'm talking about in this question are doing. The cabling and devices that this question is about transmit the analog VGA data over the HDMI port (the HDMI port is in the device outputting the data, and the VGA side is the monitor/projector).

    Read the article

  • ZFS: Mirror vs. RAID-Z

    - by John Clayton
    I'm planning on building a file server using OpenSolaris and ZFS that will provide two primary services - be an iSCSI target for XenServer virtual machines & be a general home file server. The hardware I'm looking at includes 2x 4-port SATA controllers, 2x small boot drives (one on each controller), and 4x big drives for storage. This allows one free port per controller for upgrading the array down the road. Where I'm a little confused is how to setup the storage drives. For performance, mirroring appears to be king. I'm having a hard time seeing what the benefit would be of using RAIDZ over mirroring would be. With this setup I can see two options - two mirrored pools in one stripe, or RAIDZ2. Both should protect against 2 drive failures, and/or one controller failure...the only benefit of RAIDZ2 would be that any 2 drives could fail. The storage should be 50% of capacity in both cases, but the first should have much better performance, right? The other thing I'm trying to wrap my mind around is the benefit of mirrored arrays with more than two devices. For data integrity what, if any, would be the benefit of a RAIDZ over a three-way mirror? Since ZFS maintains file integrity what does RAIDZ bring to the table...doesn't ZFS's integrity checks negate the value of RAIDZ's parity?

    Read the article

  • Apache Simple Configuration Issue: Setting up per-user directory permission denied problem

    - by Huckphin
    Hello. I am just getting Apache 2.2 running on Fedora 13 Beta 64-bit. I am running into issues setting my per-user directory. The goal is to make localhost/~user map to /home/~user/public_html. I think that I have the permissions right because I have 755 to /home/~user, and I have 755 to /home/~user/public_html/ and I have 777 for all contents inside of /home/~user/public_html/ recursively set. My mod_userdir configuration looks like this: <IfModule mod_userdir.c> # # UserDir is disabled by default since it can confirm the presence # of a username on the system (depending on home directory # permissions). # UserDir disabled root UserDir enabled huckphin # # To enable requests to /~user/ to serve the user's public_html # directory, remove the "UserDir disabled" line above, and uncomment # the following line instead: # UserDir public_html The error that I am seeing in the error log is this: [Sat May 15 09:54:29 2010] [error] [client 127.0.0.1] (13)Permission denied: access to /~huckphin/index.html denied When I login as the apache user, I know that /~huckphin does not exist, and this is not what I want. I want it to be accessing ~huckphin, not /~huckphin. What do I need to change on my configuration for this to work? [Added after comments] Hi Andol, thank you for your suggestions. So, first off, you said that you assume that I have the userdir module enabled, but I am not sure what that means exactly. That could be part of the problem. I do have the Module loaded, using the LoadModule directive. I have this: LoadModule userdir_module modules/mod_userdir.so I also did a find on where mod_userdir is, and I found it located here: [huckphin@crhyner-workbox]/% find / . -name '*mod_userdir.so*' 2> /dev/null /usr/lib64/lighttpd/mod_userdir.so /usr/lib64/httpd/modules/mod_userdir.so Is there something else I need to enable? Also, my directory configuration was mentioned. I have uncommented the default configuration given. I have not looked into what all of the configurations mean, and this could probably explain the issue. Here is the Directory that I have for the user directories: <Directory "/home/*/public_html"> AllowOverride FileInfo AuthConfig Limit Options MultiViews Indexes SymLinksIfOwnerMatch IncludesNoExec <Limit GET POST OPTIONS> Order allow,deny Allow from all </Limit> <LimitExcept GET POST OPTIONS> Order deny,allow Deny from all </LimitExcept> </Directory>

    Read the article

  • Getting Classic ASP to work in .js files under IIS 7

    - by Abdullah Ahmed
    I am moving a clients classic asp webapp to a new IIS7 based server. The site contains some .js files which have javascript but also classic asp in <% % tags which contains a bunch of conditional statements designed to spit out pieces of javascript based on session state variables. Here's a brief example of what the file could be like.... var arrHOFFSET = -1; var arrLeft ="<"; var arrRight = ">"; <% If ((Session("dashInv") = "True") And ((Session("systemLevelStaff") = "4") Or (Session("systemLevelCompany") = "4"))) Then %> addMainItem("/MgmtTools/WelcomeInventory.asp?wherefrom=salesMan","",81,"center","","",0,0,"","","","",""); <% Else %> <% If (Session("dashInv") = "False") And ((Session("systemLevelStaff") = "4") Or (Session("systemLevelCompany") = "4")) Then %> <% Else %> addMainItem("/calendar/welcome.asp","",81,"center","","",0,0,"","","","",""); <% End If %> <% End If %> defineSubmenuProperties(135,"center","center",-3,0,"","","","","","",""); Currently this file (named custom.js for example) will start throwing js errors, because the server doesnt seem to recognize the asp code in it and therefore does not parse it. I know I need to somehow specify that a .js file should also be treated like an .asp file and run through parsing it. However I am not sure how to go about doing this. Here is what I've tried so far... Under the Server node in IIS under HANDLER MAPPINGS I created a new Script Map with the following settings. Request Path: *.js Executable: C:\Windows\System32\inetsrv\asp.dll Name: ASPClassicInJSFiles Mapping: Invoke Handler only if request is mapped to : File Verbs: All verbs Access: Script I also created a similar handler under the site node itself. Under MIME Types .js is defined as application/x-javascript None of these work. If I simply rename the file to have .asp extension then things work, however this app is poorly coded and has literally 100's of files with the .js files included in them under various names and locations, so rename, search and replace is the last option I have.

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Where do I connect the HDD LED wires on my RAID adapter?

    - by Giffyguy
    I'm using a Promise FastTrak TX8660 with RAID 5. The manual (and Google) just doesn't seem to explain how exactly to connect a standard two-pin HDD LED wire to the eight available pins on the card. The Manual just says - To connect your LED, follow the following diagram: The card itself resembles the diagram: But it doesn't make any sense to me. All I have is a two-pin connecter for HDD LED on the front of my computer case. I don't need anything fancy like the fault LED or seperate indicators for each drive. I just want to be able to see when my RAID 5 array is working, that's all. I don't know what the "R" and "G" stand for, but my HDD LED wires are red and white. I tried connecting the red wire to the "R" pin and the white wire to the "G" pin, but that just makes the LED on the front of my case light up indefinitely, even when the computer is idle. Which pins am I suppose to connect the HDD LED header to for basic activity indication?

    Read the article

  • 24TB RAID 6 configuration

    - by Phil
    I am in charge of a new website in a niche industry that stores lots of data (10+ TB per client, growing to 2 or 3 clients soon). We are considering ordering about $5000 worth of 3TB drives (10 in a RAID 6 configuration and 10 for backup), which will give us approximately 24 TB of production storage. The data will be written once and remain unmodified for the lifetime of the website, so we only need to do a backup one time. I understand basic RAID theory, however I am not experienced with it. My question is, does this sound like a good configuration? What potential problems could this setup cause? Also, what is the best way to do a one-time backup? Have two RAID 6 arrays, one for offsite backup and one for production? Or should I backup the RAID 6 production array to a JBOD? EDIT: The data server is running Windows 2008 Server x64. EDIT 2: To reduce rebuild time, what would you think about using two RAID 5's instead of one RAID 6?

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • Repairing inconsistent pages in database

    - by Raj
    We have a SQL 2000 DB. The server crashed due to Raid array failure. Now when we run DBCC CHECKDB, we get an error that there are 27 consistency errors in 9 pages. When we run DBCC PAGE on these pages, we get this: Msg 8939, Level 16, State 106, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (m_freeCnt == freeCnt) failed. Values are 2 and 19. Msg 8939, Level 16, State 108, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (emptySlotCnt == 0) failed. Values are 1 and 0. Since the indicated index is non-clustered and is created by a unique constarint that includes 2 columns, we tried dropping and recreating the index. This resulted in the following error: CREATE UNIQUE INDEX terminated because a duplicate key was found for index ID 2. Most significant primary key is '3280'. The statement has been terminated. However running Select var_id,result_on from tests group by var_id,result_on having count(*)>1 returns 0 rows. Here is what we are planning to do: Restore a pre-server crash copy of the DB and run DBCC CHECKDB If that returns clean, then restore again with no recovery Apply all subequent TLOG backups Stop production app, take a tail log backup and apply that too Drop prod DB and rename the freshly restored DB to make it prod Start prod app Could someone please punch holes in this approach? Maybe, suggest a different approach? What we need is minimum downtime. SQL 2000 DB Size 94 GB The table that has corrupt pages has 460 Million+ rows of data Thanks for the help. Raj

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here.

    Read the article

  • nginx - Redirect specific page paths to https while keeping everything else on http (in a single server call)?

    - by Kris Anderson
    From what I've gathered so far it's clear that running if statements in nginx should be avoided at all costs. Most of the examples I've found so far regarding specific page redirects involve multiple servers being used. But, isn't that a bit wasteful? I'm not sure, but I would think multiple servers to accomplish this would be somewhat slower then a single server when under heavy load. My current server call is this: server { listen 10.0.0.60:80; listen 10.0.0.60:443 default ssl; #other code } What I want to do is redirect certain http requests to https requests. For example, I want /login/ and /my-account/ to always be forced to use SSL. If you're on /help/ though, I want that served over the default http. Is there a way to accomplish this within a single server call? Or is there no downside to using 2 server calls to get this working? nginx seems to be under pretty active development and a lot of the older guides I've followed were from times when you couldn't listen to requests for port 80 and 443 within the same server call. But now that nginx has been updated to support that (I'm running 1.2.4), I'm wondering if there's a "best practice" way of handling this today. Any help would be greatly appreciated. EDIT: I did find this guide: http://redant.com.au/blog/manage-ssl-redirection-in-nginx-using-maps-and-save-the-universe/ and I updated my code as follows: map $uri $my_preferred_proto { default "http"; ~^/#/user/login "https"; } server { listen 10.0.0.60:80; ## listen for ipv4; this line is default and implied listen 10.0.0.60:443 default ssl; if ($my_preferred_proto = "none") { set $my_preferred_proto $scheme; } if ($my_preferred_proto != $scheme) { return 301 $my_preferred_proto://mysite.com$request_uri; } It's not working though. When I change the default to https everything is redirected to SSL so it does somewhat work. But the redirect of /#/user/login is not redirecting to HTTPS. Any ideas? Also, is this a good way to go about this?

    Read the article

  • Disk IO slow on ESXi, even slower on a VM (freeNAS + iSCSI)

    - by varesa
    I have a server with ESXi 5 and iSCSI attached network storage(4x1Tb Raid-Z on freenas 8.0.4). Those two machines are connected to each other with Gigabit ethernet. The raid-z volume is divided into three parts: two zvols, shared with iscsi, and one directly on top of zfs, shared with nfs and similar. I ssh'd into the freeNAS box, and did some testing on the disks. I used ddto test the third part of the disks (straight on top of ZFS). I copied a 4GB (2x the amount of RAM) block from /dev/zero to the disk, and the speed was 80MB/s. Other of the iSCSI shared zvols is a datastore for the ESXi. I did similar test with time dd .. there. Since the dd there did not give the speed, I divided the amount of data transfered by the time show by time. The result was around 30-40 MB/s. Thats about half of the speed from the freeNAS host! Then I tested the IO on a VM running on the same ESXi host. The VM was a light CentOS 6.0 machine, which was not really doing anything else at that time. There were no other VMs running on the server at the time, and the other two "parts" of the disk array were not used. A similar dd test gave me result of about 15-20 MB/s. That is again about half of the result on a lower level! Of course the is some overhead in raid-z - zfs - zvolume - iSCSI - VMFS - VM, but I don't expect it to be that big. I belive there must be something wrong in my system. I have heard about bad performance of freeNAS's iSCSI, is that it? I have not managed to get any other "big" SAN OS to run on the box (NexentaSTOR, openfiler). Can you see any obvious problems with my setup?

    Read the article

  • Cannot browse network shares in Windows Explorer, but paths are still accessible

    - by Jeff Lockhart
    Windows Explorer has somehow corrupted itself and I'm not sure how to fix this problem. My Windows installation has been in use for a few years with network shares setup and working. Recently, I noticed that a program that I use to save network share paths to a database was no longer opening the explorer window to browse the path. It usually opens to the last path saved, but now it was just not opening at all. When I go to Windows Explorer to browse the network share directly, I get the error \\SERVER is not accessible. You might not have permission to use this network resource. Contact the administrator of this server to find out if you have access permissions. The specified network provider name is invalid. The network shares are just shares on the server itself (once saved to the database, they're used on the server as well as clients to reach files). The strange thing is, the files are still accessible from the program that uses them if I type the network share path in manually. So it is only a problem with Windows Explorer browsing the path. The reason I think there is some sort of configuration or setting, possibly in the registry, corrupted is that when the problem first manifest itself, I was somehow able to open an explorer window to a network share path, but the breadcrumb in the address bar did not function properly. It duplicated the share name folder at the top of the breadcrumb stack and when I clicked the second of the duplicated share folder, it crashed explorer.exe. I haven't been able to browse any network share path since this happened. I have tried using the IP address directly \\192.168.1.# as well as \\localhost and neither of those work either. I have tried running sfc /scannow and it did not find any errors. I tried ipconfig /flushdns and this made no difference. Attempting to map the network share to a drive fails using either the explorer GUI or net use command. Is there some way to reset Windows Explorer somehow to resolve this? I'd really like to avoid reinstalling Windows entirely if I can.

    Read the article

  • umount bind of stale NFS

    - by Paul Eisner
    i've got a problem removing mounts created with mount -o bind from a locally mounted NFS folder. Assume the following mount structure: NFS mounted directory: $ mount -o rw,soft,tcp,intr,timeo=10,retrans=2,retry=1 \ 10.20.0.1:/srv/source /srv/nfs-source Bound directory: $ mount -o bind /srv/nfs-source/sub1 /srv/bind-target/sub1 Which results in this mount map $ mount /dev/sda1 on / type ext3 (rw,errors=remount-ro) # ... 10.20.0.1:/srv/source on /srv/nfs-source type nfs (rw,soft,tcp,intr,timeo=10,retrans=2,retry=1,addr=10.20.0.100) /srv/nfs-source/sub1 on /srv/bind-target/sub1 type none (rw,bind) If the server (10.20.0.1) goes down (eg ifdown eth0), the handles become stale, which is expected. I can now un-mount the NFS mount with force $ umount -f /srv/nfs-source This takes some seconds, but works without any problems. However, i cannot un-mount the bound directory in /srv/bind-target/sub1. The forced umount results in: $ umount -f /srv/bind-target/sub1 umount2: Stale NFS file handle umount: /srv/bind-target/sub1: Stale NFS file handle umount2: Stale NFS file handle Here is a trace http://pastebin.com/ipvvrVmB I've tried umounting the sub-directories beforehand, find any processes accessing anything within the NFS or bind mounts (there are none). lsof also complains: $ lsof -n lsof: WARNING: can't stat() nfs file system /srv/nfs-source Output information may be incomplete. lsof: WARNING: can't stat() nfs file system /srv/bind-target/sub1 (deleted) Output information may be incomplete. lsof: WARNING: can't stat() nfs file system /srv/bind-target/ Output information may be incomplete. I've tried with recent stable Linux kernels 3.2.17, 3.2.19 and 3.3.8 (cannot use 3.4.x, cause need the grsecurity patch, which is not, yet, supported - grsecurity is not patched in in the tests above!). My nfs-utils are version 1.2.2 (debian stable). Does anybody have an idea how i can either: force the un-mount some other way? (any dirty trick is welcome, data loss or damage neglible at this point) use something else instead of mount -o bind? (cannot use soft links, cause mounted directories will be used in chroot; bindfs via FUSE is far to slow to be an option) Thanks, Paul Update 1 With 2.6.32.59 the umount of the (stale) sub-mounts work just fine. It seems to be a kernel regression bug. The above tests where with NFSv3. Additional tests with NFSv4 showed no change. Update 2 We have tested now multiple 2.6 and 3.x kernels and are now sure, that this was introduced in 3.0.x. We will fille a bug report, hopefully they figure it out.

    Read the article