Search Results

Search found 27337 results on 1094 pages for 't sql'.

Page 810/1094 | < Previous Page | 806 807 808 809 810 811 812 813 814 815 816 817  | Next Page >

  • Installing Microsoft Atlanta

    - by John Paul Cook
    Since my previous post on Microsoft Atlanta, I've been asked how someone can get started with it. Go to https://www.microsoftatlanta.com/ and click the Create Account button using a Windows Live id such as a Hotmail account. If you don’t have Silverlight installed, you’ll be prompted to install it somewhere along the way. I encourage you to install Atlanta and try it out. The product is still being developed and your early feedback can make a difference. When you click Download Registration Certificate...(read more)

    Read the article

  • Building a Redundant / Distributed Application

    - by MattW
    This is more of a "point me in the right direction" question. My team of three and I have built a hosted web app that queues and routes customer chat requests to available customer service agents (It does other things as well, but this is enough background to illustrate the issue). The basic dev architecture today is: a single page ajax web UI (ASP.NET MVC) with floating chat windows (think Gmail) a backend Windows service to queue and route the chat requests this service also logs the chats, calculates service levels, etc a Comet server product that routes data between the web frontend and the backend Windows service this also helps us detect which Agents are still connected (online) And our hardware architecture today is: 2 servers to host the web UI portion of the application a load balancer to route requests to the 2 different web app servers a third server to host the SQL Server DB and the backend Windows service responsible for queuing / delivering chats So as it stands today, one of the web app servers could go down and we would be ok. However, if something would happen to the SQL Server / Windows Service server we would be boned. My question - how can I make this backend Windows service logic be able to be spread across multiple machines (distributed)? The Windows service is written to accept requests from the Comet server, check for available Agents, and route the chat to those agents. How can I make this more distributed? How can I make it so that I can distribute the work of the backend Windows service can be spread across multiple machines for redundancy and uptime purposes? Will I need to re-write it with distributed computing in mind? I should also note that I am hosting all of this on Rackspace Cloud instances - so maybe it is something I should be less concerned about? Thanks in advance for any help!

    Read the article

  • SSD-HDD price parity

    - by jchang
    It is hard to believe that we are essentially at SSD-HDD price parity? Of course I am comparing enterprise class 10K/15K HDDs to consumer grade SSDs. Below are prices I am seeing 300GB 15K HDD $370 900GB 10K HDD $600 1TB 7200 HDD $230 (less for consumer HDDs) 512GB SATA SSD $400-600 Intel SSD DC S3700 400GB $940 The 512GB SATA SSDs are consumer grade, MLC NAND, with only 7% over provisioning. That is 512GB (1GB = 2^30) of NAND, with 512GB (1GB =10^9) of user capacity. Intel just announced the SSD...(read more)

    Read the article

  • SQLBits VI hotel discount extended

    - by MartinBell
    Park Plaza have extended the deadline date for the SQLBits discount to 7th April. If you wish to take advantage of the discount make sure you book early. For more details see http://www.sqlbits.com/information/Travel.aspx...(read more)

    Read the article

  • Visiting China

    - by Bill Graziano
    This summer I had the chance to visit China.  My brother and his wife are living in China and teaching English.  I spent a little over two weeks in Shanghai, Suzhou and Yancheng.  During that time I wrote some detailed updates for family and a few close friends on the impressions of a good Midwestern kid visiting the Middle Kingdom. I dumped them all into one document, did a little editing and now they’re posted.  You can download it here.  Below you can see my futile attempts to eat using chopsticks and me posing as a tourist on Nanjing Road in Shanghai.  The only thing I can say about chopsticks is that I didn’t starve.

    Read the article

  • Clustered Index

    - by Derek Dieter
    The clustered index on a table can be defined as: the sort order for how the data for the table is actually stored. Being that the clustered index is the actual data itself, you cannot have two clustered indexes. You can however have many non clustered indexes. These non clustered indexes are [...]

    Read the article

  • Taming Hopping Windows

    - by Roman Schindlauer
    At first glance, hopping windows seem fairly innocuous and obvious. They organize events into windows with a simple periodic definition: the windows have some duration d (e.g. a window covers 5 second time intervals), an interval or period p (e.g. a new window starts every 2 seconds) and an alignment a (e.g. one of those windows starts at 12:00 PM on March 15, 2012 UTC). var wins = xs     .HoppingWindow(TimeSpan.FromSeconds(5),                    TimeSpan.FromSeconds(2),                    new DateTime(2012, 3, 15, 12, 0, 0, DateTimeKind.Utc)); Logically, there is a window with start time a + np and end time a + np + d for every integer n. That’s a lot of windows. So why doesn’t the following query (always) blow up? var query = wins.Select(win => win.Count()); A few users have asked why StreamInsight doesn’t produce output for empty windows. Primarily it’s because there is an infinite number of empty windows! (Actually, StreamInsight uses DateTimeOffset.MaxValue to approximate “the end of time” and DateTimeOffset.MinValue to approximate “the beginning of time”, so the number of windows is lower in practice.) That was the good news. Now the bad news. Events also have duration. Consider the following simple input: var xs = this.Application                 .DefineEnumerable(() => new[]                     { EdgeEvent.CreateStart(DateTimeOffset.UtcNow, 0) })                 .ToStreamable(AdvanceTimeSettings.IncreasingStartTime); Because the event has no explicit end edge, it lasts until the end of time. So there are lots of non-empty windows if we apply a hopping window to that single event! For this reason, we need to be careful with hopping window queries in StreamInsight. Or we can switch to a custom implementation of hopping windows that doesn’t suffer from this shortcoming. The alternate window implementation produces output only when the input changes. We start by breaking up the timeline into non-overlapping intervals assigned to each window. In figure 1, six hopping windows (“Windows”) are assigned to six intervals (“Assignments”) in the timeline. Next we take input events (“Events”) and alter their lifetimes (“Altered Events”) so that they cover the intervals of the windows they intersect. In figure 1, you can see that the first event e1 intersects windows w1 and w2 so it is adjusted to cover assignments a1 and a2. Finally, we can use snapshot windows (“Snapshots”) to produce output for the hopping windows. Notice however that instead of having six windows generating output, we have only four. The first and second snapshots correspond to the first and second hopping windows. The remaining snapshots however cover two hopping windows each! While in this example we saved only two events, the savings can be more significant when the ratio of event duration to window duration is higher. Figure 1: Timeline The implementation of this strategy is straightforward. We need to set the start times of events to the start time of the interval assigned to the earliest window including the start time. Similarly, we need to modify the end times of events to the end time of the interval assigned to the latest window including the end time. The following snap-to-boundary function that rounds a timestamp value t down to the nearest value t' <= t such that t' is a + np for some integer n will be useful. For convenience, we will represent both DateTime and TimeSpan values using long ticks: static long SnapToBoundary(long t, long a, long p) {     return t - ((t - a) % p) - (t > a ? 0L : p); } How do we find the earliest window including the start time for an event? It’s the window following the last window that does not include the start time assuming that there are no gaps in the windows (i.e. duration < interval), and limitation of this solution. To find the end time of that antecedent window, we need to know the alignment of window ends: long e = a + (d % p); Using the window end alignment, we are finally ready to describe the start time selector: static long AdjustStartTime(long t, long e, long p) {     return SnapToBoundary(t, e, p) + p; } To find the latest window including the end time for an event, we look for the last window start time (non-inclusive): public static long AdjustEndTime(long t, long a, long d, long p) {     return SnapToBoundary(t - 1, a, p) + p + d; } Bringing it together, we can define the translation from events to ‘altered events’ as in Figure 1: public static IQStreamable<T> SnapToWindowIntervals<T>(IQStreamable<T> source, TimeSpan duration, TimeSpan interval, DateTime alignment) {     if (source == null) throw new ArgumentNullException("source");     // reason about DateTime and TimeSpan in ticks     long d = Math.Min(DateTime.MaxValue.Ticks, duration.Ticks);     long p = Math.Min(DateTime.MaxValue.Ticks, Math.Abs(interval.Ticks));     // set alignment to earliest possible window     var a = alignment.ToUniversalTime().Ticks % p;     // verify constraints of this solution     if (d <= 0L) { throw new ArgumentOutOfRangeException("duration"); }     if (p == 0L || p > d) { throw new ArgumentOutOfRangeException("interval"); }     // find the alignment of window ends     long e = a + (d % p);     return source.AlterEventLifetime(         evt => ToDateTime(AdjustStartTime(evt.StartTime.ToUniversalTime().Ticks, e, p)),         evt => ToDateTime(AdjustEndTime(evt.EndTime.ToUniversalTime().Ticks, a, d, p)) -             ToDateTime(AdjustStartTime(evt.StartTime.ToUniversalTime().Ticks, e, p))); } public static DateTime ToDateTime(long ticks) {     // just snap to min or max value rather than under/overflowing     return ticks < DateTime.MinValue.Ticks         ? new DateTime(DateTime.MinValue.Ticks, DateTimeKind.Utc)         : ticks > DateTime.MaxValue.Ticks         ? new DateTime(DateTime.MaxValue.Ticks, DateTimeKind.Utc)         : new DateTime(ticks, DateTimeKind.Utc); } Finally, we can describe our custom hopping window operator: public static IQWindowedStreamable<T> HoppingWindow2<T>(     IQStreamable<T> source,     TimeSpan duration,     TimeSpan interval,     DateTime alignment) {     if (source == null) { throw new ArgumentNullException("source"); }     return SnapToWindowIntervals(source, duration, interval, alignment).SnapshotWindow(); } By switching from HoppingWindow to HoppingWindow2 in the following example, the query returns quickly rather than gobbling resources and ultimately failing! public void Main() {     var start = new DateTimeOffset(new DateTime(2012, 6, 28), TimeSpan.Zero);     var duration = TimeSpan.FromSeconds(5);     var interval = TimeSpan.FromSeconds(2);     var alignment = new DateTime(2012, 3, 15, 12, 0, 0, DateTimeKind.Utc);     var events = this.Application.DefineEnumerable(() => new[]     {         EdgeEvent.CreateStart(start.AddSeconds(0), "e0"),         EdgeEvent.CreateStart(start.AddSeconds(1), "e1"),         EdgeEvent.CreateEnd(start.AddSeconds(1), start.AddSeconds(2), "e1"),         EdgeEvent.CreateStart(start.AddSeconds(3), "e2"),         EdgeEvent.CreateStart(start.AddSeconds(9), "e3"),         EdgeEvent.CreateEnd(start.AddSeconds(3), start.AddSeconds(10), "e2"),         EdgeEvent.CreateEnd(start.AddSeconds(9), start.AddSeconds(10), "e3"),     }).ToStreamable(AdvanceTimeSettings.IncreasingStartTime);     var adjustedEvents = SnapToWindowIntervals(events, duration, interval, alignment);     var query = from win in HoppingWindow2(events, duration, interval, alignment)                 select win.Count();     DisplayResults(adjustedEvents, "Adjusted Events");     DisplayResults(query, "Query"); } As you can see, instead of producing a massive number of windows for the open start edge e0, a single window is emitted from 12:00:15 AM until the end of time: Adjusted Events StartTime EndTime Payload 6/28/2012 12:00:01 AM 12/31/9999 11:59:59 PM e0 6/28/2012 12:00:03 AM 6/28/2012 12:00:07 AM e1 6/28/2012 12:00:05 AM 6/28/2012 12:00:15 AM e2 6/28/2012 12:00:11 AM 6/28/2012 12:00:15 AM e3 Query StartTime EndTime Payload 6/28/2012 12:00:01 AM 6/28/2012 12:00:03 AM 1 6/28/2012 12:00:03 AM 6/28/2012 12:00:05 AM 2 6/28/2012 12:00:05 AM 6/28/2012 12:00:07 AM 3 6/28/2012 12:00:07 AM 6/28/2012 12:00:11 AM 2 6/28/2012 12:00:11 AM 6/28/2012 12:00:15 AM 3 6/28/2012 12:00:15 AM 12/31/9999 11:59:59 PM 1 Regards, The StreamInsight Team

    Read the article

  • Windows Server 2003 network boogey men every DBA should know

    - by merrillaldrich
    Recently I was again visited by my old friends TCP Chimney and SynAttackProtect . (Yeah, sometimes I feel like I mostly blog about 5-year old problems, but many of us as DBA's have to work on older versions or older systems, and so repeat older problems :-). This has been written about before, but as I BinGoogled around I noticed you are more likely to find the documents if you search for the cause, and not the symptoms. Most people who face a problem, of course, know the symptoms but not the cause....(read more)

    Read the article

  • Moving WSS sites to a new SharePoint 2010 Foundation server

    - by Gustavo Cavalcanti
    This existing question helps but it doesn't answer all my questions. I have WSS 3 running on Server1 (Server 2003) and its database is DBServer1 (SQL 2008). I have installed SharePoint 2010 Foundation on Server2 (Server 2008) with databases on DBServer2 (SQL 2008 R2). SP 2010 Foundation is up and running ok and it already has one newly created Web Application. Now my goal is to copy all sites from Server1/DBServer1 to Server2/DBServer2 (and eventually retire Server1/DBServer1). Could you please help me with a step-by-step list on how to accomplish this? Thank you!

    Read the article

  • Got that Friday feeling?

    - by Rebecca Amos
    Saturday is just around the corner, and we’re all starting to wrap up for the weekend. If you’re the DBA that ‘Friday feeling’ might be as much about checking and preparing your SQL Servers for the next two days, as about looking forward to spending time with friends and family. Whether you’re double-checking your disaster recovery strategy, or know that it’s your turn to be on-call this weekend, it’s likely you’re preparing for the worst, just in case. The fact that you’re making these checks, and caring about both your servers and your users, means that you might be an exceptional DBA. You’re already putting in that extra effort to make other people’s lives easier. So why not take some time for your professional development and enter the Exceptional DBA Awards? If you’re looking for some inspiration for your entry, download our Judges’ Top Tips poster for advice on what the judges are looking for from this year’s entrants. Not only will you be boosting your professional development, but you could win full conference registration for the 2011 PASS Summit in Seattle (where the awards ceremony will take place), four nights' hotel accommodation, and a copy of Red Gate’s SQL DBA Bundle. So take some time out for yourself this weekend and get started on your entry: www.exceptionaldba.com

    Read the article

  • Maximum execution time of 300 seconds exceeded error while importing large MySQL database

    - by Spacedust
    I'm trying to import 641 MB MySQL database with a command: mysql -u root -p ddamiane_fakty < domenyin_damian_fakty.sql but I got an error: ERROR 1064 (42000) at line 2351406: You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near '<br /> <b>Fatal error</b>: Maximum execution time of 300 seconds exceeded in <b' at line 253 However limits are set much higher: mysql> show global variables like "interactive_timeout"; +---------------------+-------+ | Variable_name | Value | +---------------------+-------+ | interactive_timeout | 28800 | +---------------------+-------+ 1 row in set (0.00 sec) and mysql> show global variables like "wait_timeout"; +---------------+-------+ | Variable_name | Value | +---------------+-------+ | wait_timeout | 28800 | +---------------+-------+ 1 row in set (0.00 sec)

    Read the article

  • Tell me a Story

    - by Geoff N. Hiten
    I recently had a friend ask me to review his resume.  He is a very experienced DBA with excellent skills.  If I had an opening I would have hired him myself.  But not because of the resume.  I know his skill set and skill levels, but there is no way his standard resume can convey that.  A bare bones list of job titles and skills does not set you apart from your competition, nor does it convey whether you have junior or senior level skills and experience.  The solution is to not use the standard format. Tell me a story.  I want to know what you were responsible for.  Describe a tough project and how you saved time/money/personnel on that project.  Link your work activity to business value.  Drop some technical bits in there since we do work in a technical field, but show me what you can do to add value to my business well above what I would pay you.  That will get my attention. The resume exists for one primary and one secondary reason.  The primary reason is to get the interview.  A Resume won’t get you a job, so don’t expect it to.  The secondary reason is to give you and the interviewer a starting point for conversations.  If I can say “Tell me more about when….” and reference an item from your resume, then that is great for both of us.  Of course, you better be able to tell me more, both from the technical and the business side, at least if I am hiring a senior or higher level position.  As for the junior DBAs, go ahead and tell your story too.  Don’t worry about how simple or basic your projects or solutions seem.  It is how you solved the problem and what you learned that I am looking for.  If you learn rapidly and think like a DBA, I can work with that, regardless of you current skill level.

    Read the article

  • Welcome to the Red Gate BI Tools Team blog!

    - by BI Tools Team
    Welcome to the first ever post on the brand new Red Gate Business Intelligence Tools Team blog! About the team Nick Sutherland (product manager): After many years as a software developer and project manager, Nick took an MBA and turned to product marketing. SSAS Compare is his second lean startup product (the first being SQL Connect). Follow him on Twitter. David Pond (developer): Before he joined Red Gate in 2011, David made monitoring systems for Goodyear. Follow him on Twitter. Jonathan Watts (tester): Jonathan became a tester after finishing his media degree and joining Xerox. He joined Red Gate in 2004. Follow him on Twitter. James Duffy (technical author): After a spell as a writer in the video game industry, James lived briefly in Tokyo before returning to the UK to start at Red Gate. What we're working on We launched a beta of our first tool, SSAS Compare, last month. It works like SQL Compare but for SSAS cubes, letting you deploy just the changes you want. It's completely free (for now), so check it out. We're still working on it, and we're eager to hear what you think. We hope SSAS Compare will be the first of several tools Red Gate develops for BI professionals, so keep an eye out for more from us in the future. Why we need you This is your chance to help influence the course of SSAS Compare and our future BI tools. If you're a business intelligence specialist, we want to hear about the problems you face so we can build tools that solve them. What do you want to see? Tell us! We'll be posting more about SSAS Compare, business intelligence and our journey into BI in the coming days and weeks. Stay tuned!

    Read the article

  • Basic Defensive Database Programming Techniques

    We can all recognize good-quality database code: It doesn't break with every change in the server's configuration, or on upgrade. It isn't affected by concurrent usage, or high workload. In an extract from his forthcoming book, Alex explains just how to go about producing resilient TSQL code that works, and carries on working.

    Read the article

  • TechEd North America 2012–Day 2 #msTechEd #teched

    - by Marco Russo (SQLBI)
    This is the second day at TechEd North America 2012 and yesterday I had many conversations about PowerPivot and SSAS Tabular. In the evening the book signing at O’Reilley booth has been a big success! I’m writing this post from the speaker’s room. It’s not crowded this morning because the keynote is going on and there are no people also in the hall, everyone is in the keynote room. Today will be a very busy day: I’ll be staffing at Technical Learning Center from 12:30pm to 3:30pm so this is a first chance for joining the conversation about Tabular and DAX. But there is another choice this evening at Community Night starting at 6:30pm until 9:00pm. Join us at this Ask the Expert event! And, well, don’t miss the Many-to-Many Relationships in BISM Tabular from Alberto this afternoon at 5:00 pm in room S330E. Look at my yesterday’s post if you want to look at our full schedule for the week. Enjoy TechEd!

    Read the article

  • Given the choice 8 out of 10 Optimisers prefer.........

    - by GrumpyOldDBA
    Did you know that included columns do not partake in the uniqueness of a unique index? ( see below ) A few months ago we upgraded our major production system from SQL2000 to SQL2008, this has allowed me to apply some of the index tuning techniques I devised for SQL2005 way back when to the current environment now we're confident we have no unexpected surprises to surface. Amongst the techniques I use is to pull information from the dmvs to find tables ( and indexes ) which are getting high numbers...(read more)

    Read the article

  • What makes a great place to work

    - by Rob Farley
    Co-incidentally, I’ve been looking for office space for LobsterPot Solutions during the same few days that Luke Hayler ( @lukehayler ) has asked for my thoughts (okay, he ‘tagged’ me) on what makes a great place to work . He lists People and Environment, and I’m inclined to agree, but with a couple of other things too. I have three children. Two of them (both boys) are in school, but my daughter is only two. For the boys’ schools, we quickly realised that what they need most is a feeling of safety...(read more)

    Read the article

  • Deletes that Split Pages and Forwarded Ghosts

    - by Paul White
    Can DELETE operations cause pages to split? Yes. It sounds counter-intuitive on the face of it; deleting rows frees up space on a page, and page splitting occurs when a page needs additional space. Nevertheless, there are circumstances when deleting rows causes them to expand before they can be deleted. The mechanism at work here is row versioning (extract from Books Online below): Isolation Levels The relationship between row-versioning isolation levels (the first bullet point) and page splits is...(read more)

    Read the article

  • ASP.NET Multi-Select Radio Buttons

    - by Ajarn Mark Caldwell
    “HERESY!” you say, “Radio buttons are for single-select items!  If you want multi-select, use checkboxes!”  Well, I would agree, and that is why I consider this a significant bug that ASP.NET developers need to be aware of.  Here’s the situation. If you use ASP:RadioButton controls on your WebForm, then you know that in order to get them to behave properly, that is, to define a group in which only one of them can be selected by the user, you use the Group attribute and set the same value on each one.  For example: 1: <asp:RadioButton runat="server" ID="rdo1" Group="GroupName" checked="true" /> 2: <asp:RadioButton runat="server" ID="rdo2" Group="GroupName" /> With this configuration, the controls will render to the browser as HTML Input / Type=radio tags and when the user selects one, the browser will automatically deselect the other one so that only one can be selected (checked) at any time. BUT, if you user server-side code to manipulate the Checked attribute of these controls, it is possible to set them both to believe that they are checked. 1: rdo2.Checked = true; // Does NOT change the Checked attribute of rdo1 to be false. As long as you remain in server-side code, the system will believe that both radio buttons are checked (you can verify this in the debugger).  Therefore, if you later have code that looks like this 1: if (rdo1.Checked) 2: { 3: DoSomething1(); 4: } 5: else 6: { 7: DoSomethingElse(); 8: } then it will always evaluate the condition to be true and take the first action.  The good news is that if you return to the client with multiple radio buttons checked, the browser tries to clean that up for you and make only one of them really checked.  It turns out that the last one on the screen wins, so in this case, you will in fact end up with rdo2 as checked, and if you then make a trip to the server to run the code above, it will appear to be working properly.  However, if your page initializes with rdo2 checked and in code you set rdo1 to checked also, then when you go back to the client, rdo2 will remain checked, again because it is the last one and the last one checked “wins”. And this gets even uglier if you ever set these radio buttons to be disabled.  In that case, although the client browser renders the radio buttons as though only one of them is checked the system actually retains the value of both of them as checked, and your next trip to the server will really frustrate you because the browser showed rdo2 as checked, but your DoSomething1() routine keeps getting executed. The following is sample code you can put into any WebForm to test this yourself. 1: <body> 2: <form id="form1" runat="server"> 3: <h1>Radio Button Test</h1> 4: <hr /> 5: <asp:Button runat="server" ID="cmdBlankPostback" Text="Blank Postback" /> 6: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 7: <asp:Button runat="server" ID="cmdEnable" Text="Enable All" OnClick="cmdEnable_Click" /> 8: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 9: <asp:Button runat="server" ID="cmdDisable" Text="Disable All" OnClick="cmdDisable_Click" /> 10: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 11: <asp:Button runat="server" ID="cmdTest" Text="Test" OnClick="cmdTest_Click" /> 12: <br /><br /><br /> 13: <asp:RadioButton ID="rdoG1R1" GroupName="Group1" runat="server" Text="Group 1 Radio 1" Checked="true" /><br /> 14: <asp:RadioButton ID="rdoG1R2" GroupName="Group1" runat="server" Text="Group 1 Radio 2" /><br /> 15: <asp:RadioButton ID="rdoG1R3" GroupName="Group1" runat="server" Text="Group 1 Radio 3" /><br /> 16: <hr /> 17: <asp:RadioButton ID="rdoG2R1" GroupName="Group2" runat="server" Text="Group 2 Radio 1" /><br /> 18: <asp:RadioButton ID="rdoG2R2" GroupName="Group2" runat="server" Text="Group 2 Radio 2" Checked="true" /><br /> 19:  20: </form> 21: </body> 1: protected void Page_Load(object sender, EventArgs e) 2: { 3:  4: } 5:  6: protected void cmdEnable_Click(object sender, EventArgs e) 7: { 8: rdoG1R1.Enabled = true; 9: rdoG1R2.Enabled = true; 10: rdoG1R3.Enabled = true; 11: rdoG2R1.Enabled = true; 12: rdoG2R2.Enabled = true; 13: } 14:  15: protected void cmdDisable_Click(object sender, EventArgs e) 16: { 17: rdoG1R1.Enabled = false; 18: rdoG1R2.Enabled = false; 19: rdoG1R3.Enabled = false; 20: rdoG2R1.Enabled = false; 21: rdoG2R2.Enabled = false; 22: } 23:  24: protected void cmdTest_Click(object sender, EventArgs e) 25: { 26: rdoG1R2.Checked = true; 27: rdoG2R1.Checked = true; 28: } 29: 30: protected void Page_PreRender(object sender, EventArgs e) 31: { 32:  33: } After you copy the markup and page-behind code into the appropriate files.  I recommend you set a breakpoint on Page_Load as well as cmdTest_Click, and add each of the radio button controls to the Watch list so that you can walk through the code and see exactly what is happening.  Use the Blank Postback button to cause a postback to the server so you can inspect things without making any changes. The moral of the story is: if you do server-side manipulation of the Checked status of RadioButton controls, then you need to set ALL of the controls in a group whenever you want to change one.

    Read the article

  • MDW Reports–New Source Code ZIP File Available

    - by billramo
    In my MDW Reports series, I attached V1 of the RDL files in my post - May the source be with you! MDW Report Series Part 6–The Final Edition. Since that post, Rachna Agarwal from MSIT in India updated the RDL files that are ready to go in a single ZIP. The reports assume that they will ne uploaded to the Report Manager’s root folder and use a shared data source named MDW. The reports also integrate with the new Query Hash Statistics reports. You can download them from my SQLBlog.com download site.

    Read the article

  • SQLTeam.com Reader Survey

    I'm conducting a survey of the readers on the site. If you have a few moments I'd appreciate it if you could fill it out. It's only nine questions and will take just a few minutes. I'm trying to learn more about what topics are interesting to SQLTeam readers.

    Read the article

  • Do you know your DNS server?

    - by John Paul Cook
    If you don’t know your DNS server is valid, you need to find out before July 9. The FBI found rogue DNS servers and replaced them with clean, safe DNS servers to protect the public. These safe, clean servers will be turned off on July 9, 2012. If your computer was compromised to use the rogue servers, it will stop resolving DNS queries on July 9 when the clean servers are turned off. The FBI has provided full technical details at http://www.fbi.gov/news/stories/2011/november/malware_110911/DNS-changer-malware.pdf...(read more)

    Read the article

< Previous Page | 806 807 808 809 810 811 812 813 814 815 816 817  | Next Page >