Search Results

Search found 3223 results on 129 pages for 'maximum'.

Page 91/129 | < Previous Page | 87 88 89 90 91 92 93 94 95 96 97 98  | Next Page >

  • Enabling JMX for proxool with tomcat

    - by dialt0ne
    I am trying to get proxool's MBeans available so that I can see/manipulate them with jconsole. I have jconsole working, but I don't see anything related to proxool. The system is using Sun Java 1.5.0_17 (I know, I know... I'm working with the developers to upgrade). JMX is enabled by modifying $JAVA_OPTS in my tomcat 5.5 startup script: SJO="$SJO -Dcom.sun.management.jmxremote" SJO="$SJO -Dcom.sun.management.jmxremote.port=4998" SJO="$SJO -Dcom.sun.management.jmxremote.authenticate=false" SJO="$SJO -Dcom.sun.management.jmxremote.ssl=false" JAVA_OPTS="$JAVA_OPTS $SJO" I have proxool configured with JNDI in server.xml: <GlobalNamingResources> <Resource name="jdbc/database" auth="Container" type="javax.sql.DataSource" factory="org.logicalcobwebs.proxool.ProxoolDataSource" user="username" password="password" proxool.driver-url="jdbc:oracle:thin:@fqdn.example.com:1521:MYSID" proxool.driver-class="oracle.jdbc.driver.OracleDriver" proxool.alias="mysid" proxool.maximum-connection-count="20" proxool.statistics="20s,5m,15m" proxool.statistics-log-level="INFO" proxool.jmx="true" proxool.verbose="true" /> </GlobalNamingResources> My test .jsp can run queries and I can see it using the connections with the proxool admin servlet, but I'm unsure if there's more I need to configure in tomcat or proxool to get JMX functioning. Advice? jmxproxy info edit: The jmxproxy servlet is working - when I go to the URL http://tomcatserver.example.com:4999/manager/jmxproxy/?qry=*:type%3DRequestProcessor,* the results are: OK - Number of results: 2 Name: Catalina:type=RequestProcessor,worker=http-8080,name=HttpRequest0 modelerType: org.apache.coyote.RequestInfo bytesSent: 0 requestBytesSent: 0 contentLength: -1 bytesReceived: 0 requestProcessingTime: 1297983483666 globalProcessor: org.apache.coyote.RequestGroupInfo@32dc51c8 requestBytesReceived: 0 serverPort: -1 stage: 0 requestCount: 0 maxTime: 0 processingTime: 0 errorCount: 0 Name: Catalina:type=RequestProcessor,worker=jk-127.0.0.1-8009,name=JkRequest794 modelerType: org.apache.coyote.RequestInfo virtualHost: tomcatserver.example.com bytesSent: 0 method: GET remoteAddr: 172.30.3.51 requestBytesSent: 0 contentLength: -1 workerThreadName: TP-Processor15 bytesReceived: 0 requestProcessingTime: 9 globalProcessor: org.apache.coyote.RequestGroupInfo@1e7d3b8e protocol: HTTP/1.1 currentQueryString: qry=*%3Atype%3DRequestProcessor%2C* requestBytesReceived: 0 serverPort: 4999 stage: 3 requestCount: 0 maxTime: 0 processingTime: 0 currentUri: /manager/jmxproxy/ errorCount: 0 And more to the point http://tomcatserver.example.com:4999/manager/jmxproxy/?qry=Catalina:type%3DEnvironment,resourcetype%3DGlobal,name%3DProxool yields: OK - Number of results: 0

    Read the article

  • What is the difference between these Pentium Extreme Edition CPUs?

    - by Giffyguy
    The CPU in question is the Pentium Extreme Edition 955. Intel's website shows four "versions", but for the most part they all look identical. They even share the same set of ordering codes. But one of them has a substantially lower TDP, which is seemingly unexplainable - since everything else is the same. Two of them say "LGA775, Tray" and I have no idea what "Tray" means either. Also, two of them have a different SPEC code. What I need to know is: What does "LGA775, Tray" mean? Why does the one CPU have a lower TDP? And what does that mean for me? Does that mean lower maximum power consumption? Does it mean the CPU may be more stable/endurant, because of a lower heat output? Why do two of them have a different SPEC code, and what does this mean? Finally, what does PLGA775 (as opposed to LGA775) mean, and do I need to be worried about that? Information from Intel's wbsite: Intel® Pentium® Processor Extreme Edition 955 (4M Cache, 3.46 GHz, 1066 MHz FSB) with SPEC Code 1 Boxed Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775 PLGA775 B1 95 Watts BX80553955 SL94N 2 Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775, Tray PLGA775 B1 130 Watts HH80553PH0994M SL94N 3 Boxed Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775 PLGA775 B1 130 Watts BX80553955 SL8WM 4 Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775, Tray PLGA775 B1 130 Watts HH80553PH0994M SL8WM

    Read the article

  • Too many concurrent connections Exchange 2010. What else is there to check?

    - by hydroparadise
    I thought that I had this under control before. But for some reason during our last email marketing promo, I start receiving from our mass email client (built in house).. The message could not be sent to the SMTP server. The transport error code is 0x800ccc67. The server repsonse was 421 4.3.2 The maximum number of concurrent connections has exceeded a limit, closing transmission channel again. There's several places I've checked to make sure that wouldn't be an issue. First I checked that receive connector was set to receive an adequate number of connections on our relay connector (1000 connections). Then, I would later find out about Throttling Policies. I created one and set all the properties I knew to set in terms of the policy following properties to 1000; EWSMaxConcurrency, OWAMaxConcurrency, CPAMaxConcurrency, and CPAMaxConcurrency. Still, the email client starts receiving the error shortly after 100 has been sent and takes about 15-30 seconds. The process is then repeatable, but still the error gets received at the same spot everytime. Is there a rate setting that I am missing? Was there a windows update that I missed looking at? Should the software have it's own throttling feature?

    Read the article

  • ubuntu dmidecode is not functioning properly

    - by Alaa Alomari
    dmidecode is giving irrelevant and conflicted results. it shows that i have two slots while the correct is 8 (the board is Tyan S5350.) uname -a Linux synd01 3.0.0-16-server #29-Ubuntu SMP Tue Feb 14 13:08:12 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux root@synd01:/home/badmin# dmidecode -t 16 dmidecode 2.9 SMBIOS 2.33 present. Handle 0x0011, DMI type 16, 15 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: None Maximum Capacity: 4 GB Error Information Handle: Not Provided Number Of Devices: 2 while root@synd01:/home/badmin# dmidecode -t 17 | grep Size Size: No Module Installed Size: No Module Installed Size: 1024 MB Size: 1024 MB Size: No Module Installed Size: No Module Installed Size: 1024 MB Size: 1024 MB also lshw shows: *-memory description: System Memory physical id: 11 slot: System board or motherboard size: 4GiB *-bank:0 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 0 slot: J3B1 clock: 166MHz (6.0ns) *-bank:1 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 1 slot: J3B3 clock: 166MHz (6.0ns) *-bank:2 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 2 slot: J2B2 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:3 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 3 slot: J2B4 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:4 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 4 slot: J3B2 clock: 166MHz (6.0ns) *-bank:5 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 5 slot: J2B1 clock: 166MHz (6.0ns) *-bank:6 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 6 slot: J2B3 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:7 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 7 slot: J1B1 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) what might cause this conflict and how can i fix it? Thanks

    Read the article

  • How to interpret iozone values

    - by Henno
    I ran a test to measure my I/O IOPS on Linux: iozone -s 4g -r 2k -r 4k -r 8k -r 16k -r 32k -O -b /tmp/results.xls iozone claims that output is in operations per second yet the numbers are too big for that to be plausible. I'm observing some 320 CMDs/s maximum on vmware esx console (esxtop, then v). File size set to 4194304 KB Record Size 2 KB Record Size 4 KB Record Size 8 KB Record Size 16 KB Record Size 32 KB OPS Mode. Output is in operations per second. Command line used: iozone -s 4g -r 2k -r 4k -r 8k -r 16k -r 32k -O -b tmpresults.xls Time Resolution = 0.000001 seconds. Processor cache size set to 1024 Kbytes. Processor cache line size set to 32 bytes. File stride size set to 17 * record size. random random bkwd record stride KB reclen write rewrite read reread read write read rewrite read fwrite frewrite fread freread 4194304 2 19025 5580 27581 29848 284 198 415 1103217 1498 18541 4340 24245 25618 4194304 4 15650 21942 18962 21068 252 1198 193 976164 1677 22802 23093 21089 21232 4194304 8 11121 11638 10273 10165 247 1196 202 625020^C The test ran for 15 hours before I pressed ^C. Is that ordinary expectation for such command line (dedicated 4 drive RAID10 LUN, 10k RPM SAS drives in EMC CX300)?

    Read the article

  • VMWare Raw Device Mapping Not Working

    - by George H. Lenzer
    While I'm waiting for VMWare support to get back to me, I thought I'd ask here. I have a 400 gig LUN presented from a fiber channel SAN to my VMWare host. It's legacy from another virtualization platform and I need to keep it as is to avoid a long period of downtime. I formatted my VMFS3 datastore with 4 meg blocks to allow up to 1 TB disks. Then I tried adding my 400 gig disk as a raw device in physical compatibility mode. I get the error: "File is larger than the maximum size supported by datastore 'Base Test'. [Base Test]VMTEST01/VMTEST01_2.vmdk Originally I had the VMFS datastore formatted with 1 meg blocks which was the cause of this problem since the largest disk allowed would be 256 gigs. But I deleted the data store and then reformatted with 4 megs blocks. I've also tried using virtual compatibility mode for the raw device but it still fails. Does anyone have any suggestions? I've been waiting for a little over a week for VMWare, but that's fine because I'm not yet a paying customer. I'm still in the eval phase.

    Read the article

  • WRT54GL Tomato Router in Client wireless mode to an iPhone Personal Hotspot

    - by Gordo
    I am trying to connect a router with Tomato firmware to an iPhone 4. The goal is to connect to the Personal Hotspot in Client Wireless mode. This should allow wired and wireless users to connect to the router rather then the iPhone. In theory this should be possible but I am having difficulty. Router Linksys WRT54GL Tomato 1.28.1816 firmware iPhone iPhone 4 iOS 5.1 (9B176) Carrier Rogers Wireless Personal Hotspot works with other devices, wifi/bluetooth/usb iPhone Personal Hotspot settings Mode: B/G Security: WPA or WPA2 Personal Encryption: AES Router IP: 172.20.10.1 Subnet: 172.20.10.0 Min IP: 172.20.10.2 Max IP: 172.20.10.14 maximum number of wireless tethered hosts is 5 I have followed the directions here: http://www.wi-fiplanet.com/tutorials/article.php/3810281 Ensured that the router subnet does not 'collide' with the iPhone subnet. Here is the configuration of the Tomato 'Basic - Network - Wireless' section: http://i.stack.imgur.com/pbmTB.png I have tried several variations of this configuration, but nothing seems to work. NOTE: I have successfully connected to my own wifi network in Wireless Client mode, so I am confident that there are no bad cables or other hardware issues. I would prefer to use Tomato, but DD-WRT maybe my only other option. Thanks!

    Read the article

  • What is the peak theoretical WiFi G user density? [closed]

    - by Bigbio2002
    I've seen a few WiFi capacity planning questions, and this one is related, but hopefully different enough not to be closed. Also, this is related specifically to 802.11g, but a similar question could be made for N. In order to squeeze more WiFi users into a space, the transmit power on the APs need to be reduced and the APs squeezed closer together. My question is, how far can you practically take this before the network becomes unusable? There will come a point where the transmit power is so weak that nobody will actually be able to pick up a connection, or be constantly roaming to/from APs spaced a few feet apart as they walk around. There are also only 3 available channels to use as well, which is a factor to consider. After determining the peak AP density, then multiply by users-per-AP, which should be easier to find out. After factoring all of this in and running some back-of-the-envelope calculations, I'd like to be able to get a figure of "XX users per 10ft^2" or something. This can be considered the physical limit of WiFi, and will keep people from asking about getting 3,000 people in a ballroom conference on WiFi. Can anyone with WiFi experience chime in, or better yet, provide some calculations for a more accurate figure? Assumptions: Let's assume an ideal environment with no reflection (think of a big, square, open room, with the APs spaced out on a plane), APs are placed on the ceiling so humans won't absorb the waves, and the only interference are from the APs themselves and the devices. As for what devices specifically, that's irrelevant for the first point of the question (AP density, so only channel and transmit power should matter). User experience: Wikipedia states that Wireless G has about 22Mbps maximum effective throughput, or about 2.75MB/s. For the purpose of this question, anything below 100KB/s per user can be deemed to be a poor user experience. As for roaming, I'll assume the user is standing in the same place, so hopefully that will be a non-issue.

    Read the article

  • Any program to help me check whether an ethernet channel can support full-length VLAN packet?

    - by Jimm Chen
    Sometimes, I have to face such a situation that I need to quickly and explicitly know whether a full length VLAN packet can traverse between two RJ45 ports. Yes, I mean 802.1Q ethernet frame with Etype=81 00 (diagram below). What I can do now is: Get two Windows PCs, for each PC, intall Intel Gigabit NIC and Intel specific driver to create a virtual NIC, with VLAN ID=3 assigned. Then connect the two PCs to each of the two RJ45 port. Finally execute ping to generate a full-length ethernet packet. ping -f -l 1472 <dest-IP> This way, I can be sure that the sent packet has the maximum "IP data payload" of 1500 bytes(8 bytes of ICMP header and 1472 bytes of ICMP data). If the ping gets reply, I know that the ethernet channel support full-length VLAN packet. From my experiment, some home switch or broad band routers(e.g. Linksys WRT54G) does not support full-length VLAN packet switching, so only ping -f -l 1468 succeeds. You see, I have to use an expensive Intel NIC to carry on that test, quite inconvenient. You know, for most laptop today, they do not equip an Intel NIC, and, even it is an Intel NIC, Intel VLAN driver, Intel has limitations on the models on which VLAN driver can be installed. So, my question is: Is there a small program that can let me send a full-length VLAN packet without installing a dedicated VLAN driver? Or better, the program has a stock feature that does the very job for my situation. Windows programs preferred, Linux solution welcome. Simpler the program, the better. Thank you.

    Read the article

  • Removing resource limits on Solaris 10

    - by mikeydonkey
    How should one remove all potential artificial resource limitations for a process? I just saw a case where a server application consumed resources so that some limitation was hit. The other shells into the same server etc were all extremely slow (waiting for something to free up for them; ie. prstat starting 5 minutes). It wasn't CPU/memory related problem so I think it has got something to do with ulimits / projects. Already managed to set the maximum open files to 500 000 and it helped a little bit. However there is something else and I can not figure out what resource is maxed out. I can get some in-house administrator probably to check this but I would like to understand how I could make sure there shouldn't be any limitations! If you think I am going the wrong way (would be better to figure out what limitation should be specfically tuned etc) please feel free to point me to the correct way. I know technical stuff - it's just Solaris 10 that is giving me headache :/

    Read the article

  • Sun Grid Engine (SGE) / limiting simultaneous array job sub-tasks

    - by wfaulk
    I am installing a Sun Grid Engine environment and I have a scheduler limit that I can't quite figure out how to implement. My users will create array jobs that have hundreds of sub-tasks. I would like to be able to limit those jobs to only running a set number of tasks at the same time, independent of other jobs. Like I might have one array job that I want to run 20 tasks at a time, and another I want to run 50 tasks at a time, and yet another that I'm fine running without limit. It seems like this ought to be doable, but I can't figure it out. There's a max_aj_instances configuration option, but that appears to apply globally to all array jobs. I can't see any way to use consumable resources, as I'd need a "complex attribute" that is per-job, and that feature doesn't seem to exist. It didn't look like resource quotas would work, but now I'm not so sure of that. It says "A resource quota set defines a maximum resource quota for a particular job request", but it's unclear if an array job's sub-tasks' resource requests will be aggregated for the purposes of the resource quota. I'm going to play with this, but hopefully someone already knows outright.

    Read the article

  • New to building computers worried about temps

    - by dave
    I'm new to building my own computers and I was wondering about maximum temperatures. I understand that the room temp can affect the computers temp but how relevent is it? I understand that if my room temp is 20°C none of my computer parts could be lower than that. But if my room is 27°C instead of 20°C would this cause my computers parts to heat up more/faster? My new computer I built myself for gaming is i7 2600k 16gb ram ddr3 1600 hd6970 2 gb 240gb ssd ( bought a nas with 3 2tb drives in raid 5 for my home network ) 850w modular psu I also have my old hp computer i3 2120 8gb ram hd6770 1tb hdd I also have 3 laptops in my household, but I am not worried about their temps, they heat up my legs but they are never under stress. Due to size and money reasons I used an old case and it only has one of the sides left on it. Is this bad for the computer and will the extra dust cause problems? Or should I leave it this way or take the missus wrath and buy a case? If so is there any certain case I should get? I don't care about looks I just want card reader and usb slots and for it to run as cool or cooler than now, my case has 1 fan. Also what are the max temps for my new and old computer parts? Is 40°C under load ok for my CPU, what about 70°C for my GPU is that ok too, or should I worry? What are normal and safe temps for my components? I have looked around but there seem to be lots of different answers. I know that 100°C is bad but I want my parts to last as long as possible and this site always seems to give good replies without arguing or flaming.

    Read the article

  • Ext3 fs: Block bitmap for group 1 not in group (block 0). is fs dead?

    - by ip
    My company has a server with one big partition with Mysql database and php files. Now this partition seems to be corrupted, as reported from kernel messages when I tried to mount it manually: [329862.817837] EXT3-fs error (device loop1): ext3_check_descriptors: Block bitmap for group 1 not in group (block 0)! [329862.817846] EXT3-fs: group descriptors corrupted! I've tried to recovery it running tools from a PLD livecd. These are the tools I have tested: - e2retrieve - testdisk - photorec - dd_rescue/dd_rhelp - ddrescue - fsck.ext2 - e2salvage without any success. dumpe2fs 1.41.3 (12-Oct-2008) Filesystem volume name: /dev/sda3 Last mounted on: <not available> Filesystem UUID: dd51610b-6de0-4392-a6f3-67160dbc0343 Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal filetype sparse_super Default mount options: (none) Filesystem state: not clean with errors Errors behavior: Continue Filesystem OS type: Linux Inode count: 9502720 Block count: 18987570 Reserved block count: 949378 Free blocks: 11555345 Free inodes: 11858398 First block: 0 Block size: 4096 Fragment size: 4096 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 16384 Inode blocks per group: 512 Last mount time: Wed Mar 24 09:31:03 2010 Last write time: Mon Apr 12 11:46:32 2010 Mount count: 10 Maximum mount count: 30 Last checked: Thu Jan 1 01:00:00 1970 Check interval: 0 (<none>) Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 128 Journal inode: 8 Journal backup: inode blocks dumpe2fs: A block group is missing an inode table while reading journal inode e2fsck 1.41.3 (12-Oct-2008) fsck.ext3: Group descriptors look bad... trying backup blocks... fsck.ext3: A block group is missing an inode table while checking ext3 journal for /dev/sda3 I tried also backup superblocks, same error result. There's any other tools I have to test before considering these disk definitely unrecoverable? Many thanks, ip

    Read the article

  • To what extent is size a factor in SSD performance?

    - by artif
    To what extent is the size of an SSD a factor in its performance? In my mind, correct me if I'm wrong, a bigger SSD should be, everything else being equal, faster than a smaller one. A bigger SSD would have more erase blocks and thus more leeway for the FTL (flash translation layer) to do garbage collection optimization. Also there would be more time before TRIM became necessary. I see on Wikipedia that it remarks that "The performance of the SSD can scale with the number of parallel NAND flash chips used in the device" so it seems throughput also increases significantly. Also many SSDs contain internal caches of some sort and presumably those caches are larger for correspondingly large SSDs. But supposing this effect exists, I would like a quantitative analysis. Does throughput increase linearly? How much is garbage collection impacted, if at all? Does latency stay the same? And so on. Would the performance of a 8 GB SSD be significantly different from, for example, an 80 GB SSD assuming both used high quality chips, controllers, etc? Are there any resources (webpages, research papers, presentations, books, etc) that discuss correlations between SSD performance (4 KB random write speed, latency, maximum sequential throughput, etc) and size? I realize this does not really sound like a programming question but it is relevant for what I'm working on (using flash for caching hard drive data) which does involve programming. If there is a better place to ask this question, eg a more hardware oriented site, what would that be? Something like the equivalent of stack overflow (or perhaps a forum) for in-depth questions on hardware interfaces, internals, etc would be appreciated.

    Read the article

  • Screen Flicker on a black MacBook

    - by sixtyfootersdude
    I have a MacBook Black. For about the last six months I have had a strange screen flicker when I: start my machine and plug in the power cord of my machine This morning when I woke up my computer the screen backlight did not turn on at all. When I held the computer in direct sunlight I could see the screen and I could tell that everything was working normally (other than the backlight). Pressing the screen brightness controls (F2) brought up the brightness panel. The brightness panel informed me that the screen was at maximum brightness. I did a bit of Searching and this is what I found: This post describes how to buy and replace a macbook screen. Do you think that this would solve my problem? Additional info: I am running 10.6.4 I recently upgraded from 10.4. I experienced similar issues in 10.4. I am pretty sure that this is a hardware issue. The problem does not occur when the screen is at a specific angle. It usually only happens at startup/wakeup or when the power is plugged/unplugged.

    Read the article

  • which grabber is good enough to get 1000fps?

    - by user261002
    I have two framegrabber with a fast camera (1800+ fps). can anybody who understand the hardware, explain to me which of the following grabbers can help me more to grab 1000fps ? here are the the features of the two grabbers : Inspecta-5 Full Camera Link® Version: · Support for line scan and area cameras. · Video data rate of up to 660 Mbytes/sec. · PCI – X bus interface for 64 Bit data width and 66 MHz clock frequency. · PCI bus interface for 32 Bit data width and 33 MHz clock frequency. · 2 Gigabyte Onboard Memory for fast video streams. · Four opt coupled input- output ports for external trigger and encoder signals. · 528 Mbytes/sec. maximum data rate on the PCI–X Bus. · SDK for Windows 2000/XP SILICONSOFTWARE V-Series Camera Link : “microEnable IV VD4-CL” · Camera Pixel Clock Support 85 MHz · Area Scan Cameras 32k * 64k max. image size · Line Scan Cameras 64k max. image width · Acquisition Buffer: 512 MB DDR-RAM · Sustainable Transfer Rate (max.) 850 MBytes/sec. · microEnable SDK for Windows XP/Vista/ 7/ Linux

    Read the article

  • Unable to connect via NetBIOS Name

    - by grom
    I can't connect to machines/shares by NetBIOS names. Below is console output showing the problem. C:\>nbtstat -n Local Area Connection: Node IpAddress: [192.168.1.100] Scope Id: [] NetBIOS Local Name Table Name Type Status --------------------------------------------- BEAST <00> UNIQUE Registered WORKGROUP <00> GROUP Registered BEAST <20> UNIQUE Registered WORKGROUP <1E> GROUP Registered WORKGROUP <1D> UNIQUE Registered ..__MSBROWSE__.<01> GROUP Registered C:\>nbtstat -A 192.168.1.3 Local Area Connection: Node IpAddress: [192.168.1.100] Scope Id: [] NetBIOS Remote Machine Name Table Name Type Status --------------------------------------------- BRCLAPTOP <00> UNIQUE Registered WORKGROUP <00> GROUP Registered BRCLAPTOP <20> UNIQUE Registered WORKGROUP <1E> GROUP Registered MAC Address = 00-1C-BF-14-B8-6E C:\>ping beast Pinging beast [fe80::59b8:179f:b90b:a63f%11] with 32 bytes of data: Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Ping statistics for fe80::59b8:179f:b90b:a63f%11: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms C:\>ping brclaptop Ping request could not find host brclaptop. Please check the name and try again. C:\>nbtstat -a brclaptop Local Area Connection: Node IpAddress: [192.168.1.100] Scope Id: [] Host not found.

    Read the article

  • SQLSTATE[HY000]: General error: 2006 MySQL server has gone away

    - by Barkat Ullah
    Server details: RAM: 16GB HDD: 1000GB OS: Linux 2.6.32-220.7.1.el6.x86_64 Processor: 6 Core Please see the link below for my # top preview: I can often see the error mentioned in title in my plesk panel and my /etc/my.cnf configuration are as below: bind-address=127.0.0.1 local-infile=0 datadir=/var/lib/mysql socket=/var/lib/mysql/mysql.sock user=mysql max_connections=20000 max_user_connections=20000 key_buffer_size=512M join_buffer_size=4M read_buffer_size=4M read_rnd_buffer_size=512M sort_buffer_size=8M wait_timeout=300 interactive_timeout=300 connect_timeout=300 tmp_table_size=8M thread_concurrency=12 concurrent_insert=2 query_cache_limit=64M query_cache_size=128M query_cache_type=2 transaction_alloc_block_size=8192 max_allowed_packet=512M [mysqldump] quick max_allowed_packet=512M [myisamchk] key_buffer_size=128M sort_buffer_size=128M read_buffer_size=32M write_buffer_size=32M [mysqlhotcopy] interactive-timeout [mysqld_safe] log-error=/var/log/mysqld.log pid-file=/var/run/mysqld/mysqld.pid open_files_limit=8192 As my server httpd conf is set to /etc/httpd/conf.d/swtune.conf and the configuration is as below: at prefork.c: <IfModule prefork.c> StartServers 8 MinSpareServers 10 MaxSpareServers 20 ServerLimit 1536 MaxClients 1536 MaxRequestsPerChild 4000 </IfModule> If I run grep -i maxclient /var/log/httpd/error_log then I can see everyday this error: [root@u16170254 ~]# grep -i maxclient /var/log/httpd/error_log [Sun Apr 15 07:26:03 2012] [error] server reached MaxClients setting, consider raising the MaxClients setting [Mon Apr 16 06:09:22 2012] [error] server reached MaxClients setting, consider raising the MaxClients setting I tried to explain everything that I changed to keep my server okay, but maximum time my server is down. Please help me which parameter can I change to keep my server okay and my sites can load fast. It is taking too much time to load my sites.

    Read the article

  • GA 8KNXP Rev1.0: 4GB installed, only 3.5 recognized by BIOS

    - by hurikhan77
    I've installed 2x 1 GB and 4x 512 MB memory into my GA-8KNXP system which would sum up to 4GB. The specs from the manual say: Maximum memory support: 4GB. If all six slots are utilized, slot 5+6 may only equipped with single-sided RAM modules. And so I did. Anyway: The BIOS counts up to 3.5 GB and finishes there. Also my linux system reports only 3.5 GB of memory although 4 GB memory support is activated in the kernel. So I suppose this is a memory mapping issue or a hardware issue. I've tried removing only on of the 512 MB memory modules leaving 5 modules in place. But that just stopped the system from powering on correctly (screen stays black although fans and leds come to live). Dual Channel was detected and enabled so the system technically found all 6 modules. "dmidecode" in linux reports only memory in slots 1 to 4 and ignores slots 5+6, so it only detects 3 GB of memory. It also says the system would support up to 16 GB of memory with 4 GB modules per slot. I think technically the chipset should be able to offer and utilize the complete 4 GB memory range. Any clues what else I could check? Or do I have just to live with 0.5 GB wasted memory?

    Read the article

  • Vista Screen resolution Changes when Switching Users

    - by Benjol
    I regularly have a problem when switching between users in Vista - the screen resolution drops down to 800x600. If I try to set the resolution back to the maximum, it says nothing, but just keeps it at 800x600. I can set it back to an intermediate value. Otherwise I have to either restart the PC, or sometimes if I log off one of the users, I can then set the resolution back to max. Might it also have something to do with using sleep mode instead of performing regular shutdowns? I thought it might be related to the desktop background image taking up too much space, but even with plain colours, the problem still occurs. There is an enormous thread on this here, but not really any answers. From what I can gather from that thread, it isn't related to any particular applications, nor limited to a particular make of graphics card or monitor, so I don't think that including hardware details is useful. This is a very annoying problem, as it screws up my desktop and screen layout every single time. Has anyone here experienced this problem or found a solution? I've noticed that Windows Update has tried to install nVidia updates and apparently they've failed on several occasions. Not sure if that is of any relevance or not. UPDATE The last post on the thread: FWIW - I had this problem for about 2 years and wrote a number of posts in this thread in the past. It survived OS reinstallation, change of practically all of my hardware piece by piece (mobo, cpu, monitor, graphics card, memory, power supply...) I used to be affected by this annoying problem at least once every 24-48 hours. About 1.5 months ago I wiped out my 32 bit vista ultimate installation and installed Windows7 ultimate 64 bit from scratch and never saw this problem again. GOOD RIDDANCE. Vista was a pathetic piece of __ that felt like a flashback to the old [horrible] NT4/Windows95 days. I was seriously considering switching over to Apple/Mac OSX if this problem persisted.

    Read the article

  • How to configure a large mtu (linux)

    - by Somejan
    I have a gigabit ethernet connection from my laptop to my router, and a working ipv6 connection to the internet. I can receive very large packets from sites on the internet, with sizes up to at least 10000 bytes (according to wireshark). (edit: turns out to be linux's 'generic receive offload') However, when trying to send anything, my local computer fragments at just below 1500 bytes for ipv6. (On ipv4, I can send tcp packets to the internet of at least 1514 bytes, I can ping with packets up to the configured mtu of 6128 but they are blackholed.) I'm on ubuntu 12.04. I have configured an mtu for my eth0 of 6128 (the maximum it accepts), both using ip link set dev eth0 mtu 6128 and in the NetworkManager applet gui, and restarted the connection. ip link show eth0 shows the 6128 mtu is indeed set. ip -6 route shows that none of the paths the kernel knows about have an mtu set. I can ping over ipv4 with packets up to 6128 bytes (though I don't get responses), but when I do ping6 myrouter -c3 -s1500 -Mdo I get error replies from my own computer saying that the packets are too large and the mtu is 1480. I have confirmed with Wireshark that nothing is put on the wire, and the replies are indeed generated by my own computer. So, how do I get my computer to use the larger mtu?

    Read the article

  • Flash drive suddenly died. Why? Can I recover it?

    - by mg
    Hi, I have a flash drive that I used not too much but, after few month of inactivity, it died. I know that flash drives have a limited write cycles but I am sure that this is not the problem. I tried to create a new partition table and format the drive nothing worked. This is the output of mkfs.ext2. marco@pinguina:~$ sudo LANG=en.UTF-8 mkfs.ext2 -v -c /dev/sdc1 [sudo] password for marco: mke2fs 1.41.11 (14-Mar-2010) fs_types for mke2fs.conf resolution: 'ext2', 'default' Calling BLKDISCARD from 0 to 4001431552 failed. Filesystem label= OS type: Linux Block size=4096 (log=2) Fragment size=4096 (log=2) Stride=0 blocks, Stripe width=0 blocks 244320 inodes, 976912 blocks 48845 blocks (5.00%) reserved for the super user First data block=0 Maximum filesystem blocks=1002438656 30 block groups 32768 blocks per group, 32768 fragments per group 8144 inodes per group Superblock backups stored on blocks: 32768, 98304, 163840, 229376, 294912, 819200, 884736 Running command: badblocks -b 4096 -X -s /dev/sdc1 976911 badblocks: Input/output error during ext2fs_sync_device Checking for bad blocks (read-only test): done Block 0 in primary superblock/group descriptor area bad. Blocks 0 through 2 must be good in order to build a filesystem. Aborting.... Is there something I can do to recover it?

    Read the article

  • Strange battery behavior on laptop

    - by EpsilonVector
    My laptop is behaving rather strangely lately, and I was hoping to get some idea as to what may be causing such symptoms. The problem: When charging, very minute or so it loses connectivity with the AC adapter for a split second, and regains it back immediately. When this happens the little light that indicates the computer is plugged in does flicker off and back on, but I checked the adapter by replacing the battery on my laptop, and this indeed solves the problem, so it is probably the battery which is at fault, not the adapter (I also tried to move the adapter's wire around just to make sure it had nothing to do with torn wires). I suppose that the obvious solution is to get a new battery, but as far as battery defects go- this is a rather strange one; it loses connection with the adapter, but still powers the computer, and changing the power setting to a balanced plan (was maximum performance) seem to have solved the problem too. Is there a chance this is not simply the battery, but some kind of other electronic defect? And if not, what can cause it to behave so strangely? PS I tried to recalibrate it- didn't help.

    Read the article

  • creating a backup system with freenas

    - by masfenix
    We are currently in the process of opening a new accounting firm in the new year (actually moving from our previous location). I am looking for a cheap/free solution to back up our files (small, text files couple of kb). I was impressed with FreeNas and Windows Backup but I found out that Windows Backup only saves for a maximum of 2 years. The work machines will be running Windows 8 or Windows 7. There can be many work machines however we have only one to start with (ie, think of it as just one employee). I have an old core 2 duo with 2 gigs of ram that I can convert to a server if need be. I want the syncing to be done through LAN since the data is confidential and should never touch the outside world. So ideally, I would like the following scenario: A skydrive/dropbox like service to sync my client files over work machines and a central server. The "server" part should store history of files (i don't know how this will be done since the file will have the same name?). This isn't really necessary, but I can see it become useful. I am not familiar with RAID, so does any software RAID solution exist? I will most likely be buying 2 hard drives.

    Read the article

  • How browsers handle multiple IPs

    - by Sandman4
    Can someone direct me to information on exact browsers behavior when browser gets multiple A records for a given hostname (say ip1 and ip2), and one of them is not accessible. I interested in EXACT details, like (but not limited to): Will browser get 2 IPs from OS, or it will get only one ? Which ip will browser try first (random or always the first one) ? Now, let's say browser started with the failed ip1 For how long will browser try ip1 ? If user hits "stop" while it waits for ip1, and then clicks refresh which IP will browser try ? What will happen when it times-out - will it start trying ip2 or give error ? (And if error, which ip will browser try when user clicks refresh). When user clicks refresh, will any browser attempt new DNS lookup ? Now let's assume browser tried working ip2 first. For the next page request, will browser still use ip2, or it may randomly switch ips ? For how long browsers keep IPs in their cache ? When browsers sends a new DNS request, and get SAME ips, will it CONTINUE to use the same known-to-be-working IP, or the process starts from scratch and it may try any of the two ? Of course it all may be browser dependent, and may also vary between versions and platforms, I'd be happy to have maximum of details. The purpose of this - I'm trying to understand what exactly users will experience when round-robin DNS based used and one of the hosts fails. Please, I'm NOT asking about how bad DNS load balancing is, and please refrain from answering "don't do it", "it's a bad idea", "you need heartbeat/proxy/BGP/whatever" and so on.

    Read the article

< Previous Page | 87 88 89 90 91 92 93 94 95 96 97 98  | Next Page >