Search Results

Search found 2510 results on 101 pages for 'hp pavilion'.

Page 10/101 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • How to perform diagnostics (stress test) on HP Smartarray Controller

    - by pepoluan
    At my office, we have a server that we suspect its RAID controller (HP Smartarray) is failing. A cold boot, however, does not indicate anything. Can anyone recommend me a method to stress-test the controller? Symptoms that makes me suspect a failing controller: Disk access getting slower, queue getting longer Running dmesg on the XenServer console I see many messages similar to this one: end_request: I/O error, dev tda, sector 253655584 (the sector number is never the same) When we move the VM to another physical host, we no longer see the above message Running idle (without any running VM), the dmesg no longer emit the above message A search on Google indicated that the above message is most commonly associated with a failing SmartArray controller. How can I be sure that the SmartArray controller is failing?

    Read the article

  • HP Officejet 6000 E609n unexpectedly goes offline

    - by Sajee
    My local library has a number of Windows Vista SP1 PCs connected to two HP Officejet 6000 E609n wireless printers. Each PC can print to either of the two printers and one of the two printers is the default on each PC. This configuration has worked well over the last year w/o any trouble. Recently, the library staff is reporting that sometimes when patrons try to print, they can't. Closer inspection shows that the the default wireless printer is offline. In order to get the printer online again, the printer has to be restarted. In Control Panel Printers applet, under the Printer menu, the "Use Printer Offline" option is grayed out and there's no way to bring the printer back online w/o restarting it. Does anyone know what's going on here?

    Read the article

  • HP Proliant ML115 G5 - Boot order lost after reboot

    - by Filipe YaBa Polido
    I have one HP Proliant ML 115 G5 (AMD) with the latest BIOS (07-06-2009) and recently I've installed an USB disk. This is a common problem on old Proliant servers. When you plug the USB disk, BIOS boot order changes and tries to boot via USB. So, I'll change the BIOS settings and make the SATA disk the default boot device. The problem is, when I need to unplug the usb disk, and plug it again later. I can't be always changing the BIOS settings... How can one solve this for ever?!?!

    Read the article

  • Server 2008 R2 - Cannot add HP UPD PCL 6 - Failed with error 0x000000002

    - by Rasmus
    I am having a problem with adding a print driver to one of our 2008 R2 RDS servers. On all other RDS servers in the farm there is no problem. The print server is 2008 R2. The HP Universal Print Driver PCL 6 is installed on the print server. When trying to add a printer with the driver on the failing RDS server i just get the error "Cannnot connect to the printer. Failed with errorcode 0x00000002" I have tried to add the driver to the RDS server localy but it fails with the same error. The driver has been installed before and is currently visible in the printmanagement.msc. When trying to remove the print driver i am unable to do it because it's "Currently in use" What to do? Have tried everyting - i think :-) Thanks. /Rasmus

    Read the article

  • HP Ambient Light Sensor Adjustment

    - by Robin Day
    I have an HP nc4400 running Windows 7 64 bit. If I have the ambient light sensor enabled, it works well, but, its slightly too dim. I can turn off the light sensor and turn up the brightness manually and its more than bright enough. When I go to the brightness settings in Windows I can make the screen dimmer with the ambient light sensor enabled but cannot make it as bright as if it is disabled. So my question is, is it possible to keep the light sensor enabled but configure it so that the screen is brighter for given "ambient light". At the moment I have to turn it off whenever I'm in the office or outside in sunlight as I need the screen as bright as possible and it seems no matter how light it is, it never goes to full brightness when it's enabled.

    Read the article

  • HP Probook 6550b has issues with an external monitor

    - by chama
    I recently got a new HP Probook 6550b laptop for work. However, very often, when left alone (not put to sleep), the built in display will go dark. Not only that, but whenever I plug in an external monitor, the display will blank out as well. Sometimes after this happens, putting the laptop to sleep and then waking it up solves the problem. But only sometimes and only for a short time. The next time I plug in my monitor, it happens again. I know this isn't only my problem - 6 other people got the same laptop as I have at the same time, and we're all having such issues. Any suggestions as to the root of this problem and a way to fix it? It's driving me crazy!

    Read the article

  • hp laserjet 4200 madness

    - by C-dizzle
    I have an HP LaserJet 4200 printer that is acting really weird. I can print from internet just fine, no problem... but when I try to print from a document used in microsoft word, for example, I always get "Manual Feed Tray 1". I have racked my brain on this and cannot get it figured out. It's a networked printer and only an administrator account can make changes to it, I have also reset the printer back to factory settings, uninstalled and reinstalled onto the pc's and server it is connected to. Running out of hair since I'm pulling it all out... please help.

    Read the article

  • HP Z210 SFF: two different video cards produce no Displayport output when installed

    - by ConcernedOfTunbridgeWells
    I have a HP Z210 SFF that I'm trying to install a video card into. I've tried two different cards in Slot 2 (a Quadro FX380LP and a Quadro 600). Neither of these cards produce a displayport signal when installed. With neither installed the displayport port on the motherboard works fine with the built in graphics. When I install the cards it produces no signal and the cards don't either. The Quadro 600 is brand new and the odds of having two dead video cards is quite low. Is there something fundamental that I could be missing out - a BIOS setting maybe?

    Read the article

  • Hp Procurve Switch : port filtered

    - by user117140
    My HP Procurve switch is blocking port 22 and I dont know how to unblock it.Please let me know From the server, see port 22 is blocked [root@server ~]#nmap -p22,80,443 10.247.172.70 Starting Nmap 4.11 ( http://www.insecure.org/nmap/ ) at 2012-04-16 14:12 IST mass_dns: warning: Unable to determine any DNS servers. Reverse DNS is disabled. Try using --system-dns or specify valid servers with --dns_servers Interesting ports on 10.247.172.70: PORT STATE SERVICE 22/tcp filtered ssh ------------------> see 80/tcp filtered http 443/tcp filtered https This is blocked on cisco switch but I dont have any clue how this is done. I know that vlan is configured on switch. vlan 54 ip ospf 10.247.172.65 area 0.0.0.10 vrrp vrid 54 owner virtual-ip-address 10.247.172.65 255.255.255.192 priority 255 enable exit exit Please let me know how to unblock ssh port 22 access on this switch?

    Read the article

  • Ubuntu/Linux version recommendation for HP dv6 3122TX?

    - by sanjayav
    I purchased a HP dv6 3122TX recently and after installing Ubuntu 10.10 64 bit I ran into multiple issues like, The wireless driver is not supported by Uubntu. (1) [The driver is RaLink RT3090 ] The ethernet stopped working sometimes for no reason [The driver is Realtek RTL8111/8168B ] "Corrupted low memory at ..." issue which is described as a kernel bug in Ubuntu support forums. (It started to take me to a terminal instead of the GUI and couldn't start x server after that) As I'm not an expert Ubuntu user I got fed up of all these issue and got back to Windows 7. But I need an Ubuntu installation up and running for my development work. What are your suggestions about a reasonable Ubuntu version that I should try? Or a different Linux variation? Should I stick to a 32-bit version? It'd be great anyone can give some advice on this issue.

    Read the article

  • HP dv9000 Vista laptop won't boot from CD/DVD drive

    - by ScottEdwards2000
    My HP dv9000 Vista laptop recently got the BSOD with error 0x0000c1f5. The only way to fix this error is to be able to boot from CD/DVD and use some repair software I have. The problem is that the laptop REFUSES to boot from any CD/DVD I try. I've changed the boot order so the CD/DVD is first, and I can hear the drive spin up a bit upon power-up, but after a second, it spins down and then the laptop tries to boot from hard drive. Any ideas? (I've tried lots of CDs so it's not the media itself) Thanks much!

    Read the article

  • Suitable companion monitors for HP LP3065 30" primary monitor

    - by Bittercoder
    I have an HP LP3065 30" monitor - now I want to add a couple of companion screens to either side of it - I've heard to people suggesting 21" monitors in portrait mode - but it seems difficult to find a suitable panel these day, as 22" wide-screen monitors have become common, and I can't seem to find anything with a suitable 1600 pixel width. Can anyone recommend a suitable monitor, and suggest what criteria are best for picking a suitable monitor - what's important to consider - I'm thinking things like: Exact resolution match? Viewing angle? Small/thin bezel?

    Read the article

  • HP Photosmart C5280 black ink not printing properly

    - by Andreas Strandfelt
    I just got a used HP Photosmart C5280 from my father in law. There is a problem with the black ink, though. Sometimes, it doesn't print and when it does, it's not really black. An example can be seen at the following link, where I created three black boxes on a Word page and printed. The outcome is somewhat blueish: Other tests with black text only come out as blank pages. I have tried using the print head cleaning utility from the menu of the printer as well as doing the cleaning myself with alcohol. Nothing has worked. Any ideas before I throw out the black cartridge?

    Read the article

  • HP DL380 G5 Predictive failure of a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • High IO latency on ESXi 4.1 on HP DL580 G7

    - by teddydestodes
    at my Company we were experiencing some weird spikes on IO latency on one of our ESXi instances. we've spend 24h figuring out whats wrong and no clue so far. after giving up we put all the disks into a different server (HP DL380 G7) with much less RAM and only one 6(HT) cores (from 12 on the DL 580) which run fine for about 2 hours. I dont know the specs for the DL380 but both servers have a Smart Array P410i with BBWC (the DL 580 has 1GB) Is it possible that one(or all) of the disks is failing without actually failing?

    Read the article

  • HP EX485 Media Server Keeps Powering Down & Restarting Automatically

    - by AWoo
    HP Home Media Server EX485 approx 3 years old. Unit suddenly powers itself off and restarts automatically as if the power button was pressed. Server restarts up OK for a few minutes and the cycle repeats itself again & again. Reseated all drives, check fans in chassis and they are OK (turning). Can login to server to see logs before it powers itself down again. Suggestions any help is appreciated on resolving this problem. Thanks.

    Read the article

  • HP 120 printer network install con windows 7 home

    - by Fusca
    I have a HP-1210 printer connected to a win 7 ultimate edt, this one, the printer-host, is logged to a domain. I also have a Windows 7 home edition (not logged into the domain) and I want to install the hp1210 printer. Other printers in the network (connected to the domain) are currently connected to the printer. In the Win 7 Home I ran the HP1210 installer but it doesn't find the printer over the network. Is this because this win7home is not connected to the domain? Is there any way to manually specify the printer path?

    Read the article

  • HP DL380 Losing Drive Array

    - by jidl
    I have an HP Proliant DG380 G7 dropping one of it's arrays every hour, on the hour, for 2-5 minutes. The OS is SBS 2011 Standard, the servers runs Exchange, DC, files & Trend WFBS 8. I can watch the D Drive disappear for the duration of the problem - then it just comes back up and all is well again. There is no loss of network connectivity, although the mapped drives also disappear. We thought it might be to do with Sharepoint / VSS writers failing but it looks as though this is a symptom rather than cause. It survives a reboot. Any ideas as to what could be running on a regular schedule like this?

    Read the article

  • HP ENVY 4-Sleekbook or Samsung Series 5 NP530U3B Ultrabook?

    - by Sam
    I am a high school student and I need a laptop within the budget of 650$. I usually have a browser, microsoft office, music, and possibly a movie or something open at once. Will the HP ENVY 4's Intel Core i3 processor be enough to handle this or would I have to get the Samsung series 5 13 inch ultrabook to get this job done? I really like the look of the HP ENVY 4, but I also want a laptop that will be quick enough to handle my needs. PLEASE HELP!

    Read the article

  • HP Procurve Issue Passing Multiple VLANs over a link

    - by MichaelRwat
    Just to start off with I am a Cisco guy that got placed into an HP project. Basic topology overview from outside in: ASA 5505 with two Ethernet connections to a 2910-24 port switch. This switch is then (Cisco Trunking) to a 2626 switch passing vlan (1 untagged and 100 tagged)between them. I created SVI's on each of the switches for both VLAN's for testing purposes. I can not get vlan 100 to pass across this link. I also have trunks configured to AP's off of the switch and can not ping the vlan 100 BVI on the AP's but can reach the vlan 1 BVI. Port 25 on Access layer (2626) connects (trunks) with port A1 of 2610. STP is not running at all on any switch (this is not my network I can't change this nor did I design this) Distribution Sw: MP1-0# show run ip default-gateway 10.100.100.100 vlan 1 name "DATA" untagged 1-22,24-A1,B1 ip address 10.100.100.6 255.255.255.0 no untagged 23 exit vlan 100 name "GUEST" untagged 23 tagged 24-A1 ip address 10.100.102.6 255.255.255.0 exit Access Sw: ip default-gateway 10.100.100.100 vlan 1 name "DEFAULT_VLAN" untagged 1-26 ip address 10.100.100.5 255.255.255.0 exit vlan 100 name "GUEST" ip address 10.100.102.5 255.255.255.0 tagged 15,25 exitt From the ASA I can ping the vlan 100 address of the 2610 but not the 2626 (10.100.102.6)[Not passing the "trunk"] If I plug into an access port vlan 100 of the 2626 I can ping the SVI for vlan 100 as intended. I can not ping across the "trunk" over vlan 100 but I can across vlan 1. There may be something obvious I'm missing but please review my configuration and thank you for the assistance.

    Read the article

  • InterVLAN routing on a HP V1910 series switch

    - by tintix
    Recently bought a HP V1910-16G switch (former 3com 29??) with IPv4 routing capabilities. After unpacking I did a firmware upgrade to the latest 5.20 Release 1513P06. I did set up additional VLANs (#2 and #3) and VLAN interfaces for those. The problem is that connected PCs on different VLAN's can't ping each other. Looks like VLAN routing doesn't even work. So here's my setup: VLAN ID VLAN interface 1 10.0.0.21/24 2 10.0.5.1/24 3 10.0.6.1/24 Have one PC connected to VLAN 2 (IP address 10.0.5.2, default gateway 10.0.5.1) and a second PC connected to VLAN 3 (IP address 10.0.6.2, default gateway 10.0.6.1) Routing table: Destination IP Mask Next Hop 0.0.0.0 0.0.0.0 10.0.0.1 10.0.0.0 255.255.255.0 10.0.0.21 10.0.0.21 255.255.255.255 127.0.0.1 10.0.5.0 255.255.255.0 10.0.5.1 10.0.5.1 255.255.255.255 127.0.0.1 10.0.6.0 255.255.255.0 10.0.6.1 10.0.6.1 255.255.255.255 127.0.0.1 127.0.0.0 255.0.0.0 127.0.0.1 127.0.0.1 255.255.255.255 127.0.0.1 The first PC can't ping the second PC one and vice versa. They only can ping their own gateways and that's all. What I'm doing wrong?

    Read the article

  • HP Procurve 2610 intervlan routing

    - by user19039
    Can anyone tell me why inter vlan routing is working for all vlans except my newly created vlan 4/ I have an hp procurve 2610. Any help would be appreciated. I have basically this 1 switch with all unmanaged switches attached to the core. We have a second 2610 on port 28 Running configuration: ; J9085A Configuration Editor; Created on release #R.11.25 hostname "Core_HP" interface 22 speed-duplex 100-full exit ip routing snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 1-12,17-22,26-27 ip address 192.168.4.6 255.255.255.0 tagged 25 no untagged 13-16,23-24,28 exit vlan 2 name "WAN" untagged 28 ip address 10.254.254.3 255.255.255.0 exit vlan 3 name "Wireless" untagged 13-16,24 ip address 192.168.7.6 255.255.255.0 ip helper-address 192.168.4.2 tagged 27 exit vlan 35 name "guest" untagged 23 tagged 24 exit vlan 4 name "esxi" untagged 25 ip address 10.10.1.1 255.255.248.0 exit ip route 192.168.5.0 255.255.255.0 10.254.254.1 ip route 192.168.6.0 255.255.255.0 10.254.254.1 ip route 0.0.0.0 0.0.0.0 192.168.4.10 show ip route IP Route Entries Destination Gateway VLAN Type Sub-Type M etric Dist. ------------------ --------------- ---- --------- ---------- - --------- ----- 0.0.0.0/0 192.168.4.10 1 static 1 1 10.10.0.0/21 esxi 4 connected 0 0 10.254.254.0/24 WAN 2 connected 0 0 127.0.0.0/8 reject static 0 250 127.0.0.1/32 lo0 connected 0 0 192.168.4.0/24 DEFAULT_VLAN 1 connected 0 0 192.168.5.0/24 10.254.254.1 2 static 1 1 192.168.6.0/24 10.254.254.1 2 static 1 1 192.168.7.0/24 Wireless 3 connected 0 0 show ip Internet (IP) Service IP Routing : Enabled Default TTL : 64 Arp Age : 20 VLAN | IP Config IP Address Subnet Mask Prox y ARP ------------ + ---------- --------------- --------------- ---- ----- DEFAULT_VLAN | Manual 192.168.4.6 255.255.255.0 No WAN | Manual 10.254.254.3 255.255.255.0 No Wireless | Manual 192.168.7.6 255.255.255.0 No esxi | Manual 10.10.1.1 255.255.248.0 No guest | Disabled

    Read the article

  • How do I resolve certificate errors on HP blade center

    - by Martin Hilton
    I'm trying to sort out the ssl certificate errors that we get when trying to manage our HP c7000 blade enclosures. To that end I have created a signing certificate and imported it into the browser. In Onboard Administrator I created a certificate signing request, which I signed with my CA and then uploaded the certificate. This worked perfectly, and I no longer get any SSL errors when connection to Onboard Administrator. The problem comes when trying to connect through Onboard Administrator to the iLo on the blades themselves. Done by clicking on the "Web Administration" link. Onboard Administrator links to the blade with it's IP address rather than host name. But the certificate signing request that iLo creates uses the host name. Even when this certificate is signed the browser still complains it is for the wrong domain. I either need to be able to get Onboard Administrator to connect to the blades using host name rather than IP address, or get a certificate signing request which contains the IP address as the CN rather than the host name. It doesn't particularly matter which. Does anybody know how to configure this?

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • Ubuntu 12.04 - HP ProLiant DL380 G4 - Load Maxes Out / Unresponsive

    - by Brian S
    Trying to post this question on here. I've posted it on the Ubuntu forums as well with no replies. Recently I upgraded an HP ProLiant DL380 G4 server from Ubuntu 10.04 server to Ubuntu 12.04 server. Upon doing so, the server will not - at random times - get to a load of 400+ and then become completely non-responsive. I use an SNMP graphing program (cacti) and the load steadily increases by about 10 every five minutes until it gets over 400 and the graphing stops. The graphs may not be accurate, but the CPU load averages about 3% before this happens - and right when the load starts increasing, it jumps to about 25% for 15 minutes and dramatically dips down to less than 1% (about 0.3%) until the graphing stops. I'm not able to open a SSH tunnel to the server to do anything. I've checked the /var/log/syslog and all logging stops at that time as well - with nothing else in there. The odd thing is - the server still responds to DNS queries for the zones it is authoritative on during this time - and at normal speed. Just not sure what the next step would be in order to find out what is going on - and how this issue can be corrected. The server cannot stay with Ubuntu 10.04 Server and needs to stay upgraded.

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >