Search Results

Search found 7122 results on 285 pages for 'wait cursor'.

Page 109/285 | < Previous Page | 105 106 107 108 109 110 111 112 113 114 115 116  | Next Page >

  • First Foray&ndash;About timeout

    - by SQLMonger
    It has been quite a while since I signed up for this blog site and high time that something was posted.  I have a list of topics that I will be working through and posting.  Some I am sure will have been posted by others, but I will be sticking to the technical problems and challenges that I’ve recently faced, and the solutions that worked for me.  My motto when learning something new has always been “My kingdom for an example!”, and I plan on delivering useful examples here so others can learn from my efforts, failures and successes.   A bit of background about me… My name is Clayton Groom. I am a founding partner of a consulting firm in St. Louis Missouri, Covenant Technology Partners, LLC and focus on SQL Server Data Warehouse design, Analysis Services and Enterprise Reporting solutions.  I have been working with SQL Server since the early nineties, when it still only ran on OS/2. I love solving puzzles and technical challenges.   Enough about me… On to a real problem… SSIS Connection Time outs versus Command Time outs Last week, I was working on automating the processing for a large Analysis Services cube.  I had reworked an SSIS package and script task originally posted by Vidas Matelis that automates the process of adding new and dropping old partitions to/from an Analysis Services cube.  I had the package working great, tested, and ready for deployment.  It basically performs a query against the source system to determine if there is new data in the warehouse that will require a new partition to be added to the cube, and it checks the cube to see if there are any partitions that are present that are no longer needed in a rolling 60 month window. My client uses Tivoli for running all their production jobs, and not SQL Agent, so I had to build a command line file for Tivoli to use to run the package. Everything was going great. I had tested the command file from my development workstation using an XML configuration file to pass in server-specific parameters into the package when executed using the DTExec utility. With all the pieces ready, I updated the dtsconfig file to point to the UAT environment and started working with the Tivoli developer to test the job.  On the first run, the job failed, and from what I could see in the SSIS log, it had failed because of a timeout. Other errors in the log made me think that perhaps the connection string had not been passed into the package correctly. We bumped the Connection Manager  timeout values from 20 seconds to 120 seconds and tried again. The job still failed. After changing the command line to use the /SET option instead of the /CONFIGFILE option, we tested again, and again failure. After a number more failed attempts, and getting the Teradata DBA involved to monitor and see if we were connecting and failing or just failing to connect, we determined that the job was indeed connecting to the server and then disconnecting itself after 30 seconds.  This seemed odd, as we had the timeout values for the connection manager set to 180 seconds by then.  At this point one of the DBA’s found a post on the Teradata forum that had the clues to the puzzle: There is a separate “CommandTimeout” custom property on the Data source object that may needed to be adjusted for longer running queries.  I opened up the SSIS package, opened the data flow task that generated the partition list table and right-clicked on the data source. from the context menu, I selected “Show Advanced Editor” and found the property. Sure enough, it was set to 30 seconds. The CommandTimeout property can also be edited in the SSIS Properties sheet. In order to determine how long the timeout needed to be, I ran the query from the task in the development environment and received a response in a matter of seconds.  I then tried the same query against the production database and waited several minutes for a response. This did not seem to be a reasonable response time for the query involved, and indeed it wasn’t. The Teradata DBA’s adjusted the query governor settings for the service account I was testing with, and we were able to get the response back down under a minute.  Still, I set the CommandTimeout property to a much higher value in case the job was ever started during a time of high-demand on the production server. With this change in place, the job finally completed successfully.  The lesson learned for me was two-fold: Always compare query execution times between development and production environments, and don’t assume that production will always be faster.  With higher user demands, query governors, and a whole lot more data, the execution time of even what might seem to be simple queries can vary greatly. SSIS Connection time out settings do not affect command time outs.  Connection timeouts control how long the package will wait for a response from the server before assuming the server is not available or is not responding. Command time outs control how long a task will wait for results to start being returned before deciding that the server is not responding. Both lessons seem pretty straight forward, and I felt pretty sheepish once I finally figured out what the issue was.  To be fair though, In the 5+ years that I have been working with SSIS, I could only recall one other time where I had to set the CommandTimeout property, and that memory only resurfaced while I was penning this post.

    Read the article

  • What could be causing this long waiting time on page load?

    - by Andrew Findlay
    What could be causing a 1.18s wait time when my page loads? Just to make sure I did not have any conflicting or parallel scripts loading, I completely deleted all the script on my home page and ran the speed test again. Although I had a blank website and 5kb file size, there was still a 900ms "waiting" time. I'm wondering if it could be my server? Any other thoughts or suggestions as it doesn't seem to be scripts. EDIT - Just ran a DNS test on pingdom and here are my results. Does this tell me anything? No nameservers found at child?

    Read the article

  • Possible to use screen lock as timeout? [duplicate]

    - by Alex
    This question already has an answer here: Any app that tells me to take regular breaks from working? 3 answers What I'd like to do is lock the screen and have it wait a set amount of time (eg 20 mins) before it lets me log back in - so I make myself to have a break from the computer. Is it possible to do this? Thanks EDIT: Thanks for the suggestions - but I don't actually want something to remind me to take scheduled breaks. More something I can click when I realise I'm getting distracted and it'll immediately lock the screen for a fixed amount of time. Or even just lock screen if I can find a way to stop it letting me log in for 20 mins or so.

    Read the article

  • XBMC freezes pc after viewing movies

    - by Eric
    Tough to replicate, but basically after watching any movie in my library on XBMC, it'll randomly start freezing my pc. All I can do is either force shutdown by holding down the power button or wait for it to shut itself down. It's not any particular movie, it's not any particular amount of time watching one. It only happens while using XBMC. PC is older, I know the hardware is outdated, but it's not overheating nor is a simple movie too much for it to play, at least I don't think it is. Specs: Intel Core 2 6400. nVidia Quardro FX 560 4GB RAM So any suggestions? I don't have any bug/error reports because it doesn't print out any. I'm trying to find a program like XBMC, as I like having my movies organized and not have to hunt through folders to find them, so any suggestions there?

    Read the article

  • Why does this static field always get initialized over-eagerly?

    - by TheSilverBullet
    I am looking at this excellent article from Jon Skeet. While executing the demo code, Jon Skeet says that we can expect three different kinds of behaviours. To quote that article: The runtime could decide to run the type initializer on loading the assembly to start with... Or perhaps it will run it when the static method is first run... Or even wait until the field is first accessed... When I try this out (on framework 4), I always get the first result. That is, the static method is initialized before the assembly is loaded. I have tried running this multiple times and get the same result. (I tried both the debug and release versions) Why is this so? Am I missing something?

    Read the article

  • How do I cancel a time-delayed screenshot?

    - by coversnail
    I'm using the default screenshot application that comes with Ubuntu gnome-screenshot When I was using it earlier to take screenshots of the lock screen I had set a long time delay, but forgot to change it back after I'd finished. When I next took a timed screenshot I had to wait a long time for it to take because the delay was still set so long. Clicking the icon to relaunch the screenshot application has no effect whilst the timer is in effect, I imagine there is probably a simple terminal command to shut down an application, but I don't know it! Is there a way to do this?

    Read the article

  • Download mirrors down after fresh installation

    - by user169866
    I dont know whats the problem but it seems after every fresh installation of ubuntu in any device (have started noticing this problem since ubuntu 11.04) the connection to the software sources are down. I cannot download any software from either apt-get or software center. Also i cannot use the Universal Source for packages like chromium, etc. And then suddenly after a few days, the mirrors are back up again!! Its normal back again! I dont know what the problem is, but it happens every time. Is there any solution to this or we just have to wait for a few days till the mirrors are back again? (and I have also tried changing the download server, It doesn't helps!)

    Read the article

  • Naming a predicate: "precondition" or "precondition_is_met"?

    - by RexE
    In my web app framework, each page can have a precondition that needs to be satisfied before it can be displayed to the user. For example, if user 1 and user 2 are playing a back-and-forth role-playing game, user 2 needs to wait for user 1 to finish his turn before he can take his turn. Otherwise, the user is displayed a waiting page. This is implemented with a predicate: def precondition(self): return user_1.completed_turn The simplest name for this API is precondition, but this leads to code like if precondition(): ..., which is not really obvious. Seems to me like it is more accurate to call it precondition_is_met(), but not sure about that either. Is there a best practice for naming methods like this?

    Read the article

  • How long can a user remember what they were working on? [migrated]

    - by GlenPeterson
    A web application lets the user browse its screens for future or past months. The time period the user is currently viewing follows the user through every screen of the system. But users can be logged in for a month or more. After a certain period of inactivity, we will prompt the user: You were viewing November 2008 when you last clicked. Want to view the current (default) time period instead? How long between user clicks should we wait to show this message? I'm guessing somewhere between 30 minutes and 3 hours most people will forget what they were doing, but I'd love to have some data, or someone's experience to base it on. Other suggestions related to this issue?

    Read the article

  • Don&rsquo;t Miss &ldquo;Transform Field Service Delivery with Oracle Real-Time Scheduler&rdquo;

    - by ruth.donohue
    Field resources are an expensive element in the service equation. Maximizing the scheduling and routing of these resources is critical in reducing costs, increasing profitability, and improving the customer experience. Oracle Real-Time Scheduler creates cost-optimized plans and schedules for service technicians that increase operational efficiencies and improve margins. It enhances Oracle’s Siebel Field Service with real-time scheduling and dispatch capabilities that ensure service requests are allocated efficiently and service levels are honored. Join our live Webcast to learn how your organization can leverage Oracle Real-Time Scheduler to: Increase operational efficiency with real-time scheduling that enables field service technicians to handle more calls per day and reduce travel mileage Resolve issues faster with dynamic work flows that ensure you have the right technician with the right skill set for the right job Improve the customer experience with real-time planning that optimizes field technician routing, reduces customer wait times, and minimizes missed SLAs Date: Thursday, March 10, 2011 Time: 8:30 am PT / 11:30 am ET / 4:30 pm UK / 5:30 pm CET Click here to register now.   Technorati Tags: Siebel Field Service,Oracle Real-Time Scheduler

    Read the article

  • Questions and Answers from Today's Upgrade Webcast with Roy Swonger

    - by margaret hamburger
    Thanks for attending today's live webcast, 3 Compelling Reasons to Upgrade to Oracle Database 11g with Oracle Database Upgrade Expert Roy Swonger. We had an amazing turnout this morning and responded to more than 40 of your upgrade questions that I just couldn't wait to share with you. Don't worry if you missed today's live webcast. You can register for the On-Demand version to learn about Oracle Database 11g upgrade best practices with real customer examples, plus loads of great upgrade resources for making database upgrades faster and easier. You can also download a copy of our webcast presentation.

    Read the article

  • Why isn't reflection on the SCJP / OCJP?

    - by Nick Rosencrantz
    I read through Kathy Sierra's SCJP study guide and I will read it again more throughly to improve myself as a Java programmer and be able to take the certification either Java 6 or wait for the Java 7 exam (I'm already employed as Java developer so I'm in no hurry to take the exam.) Now I wonder why reflection is not on the exam? The book it seems covers everything that should be on the exam and AFAIK reflection is at least as important as threads if not more used inpractice since many frameworks use reflection. Do you know why reflection is not part of the SCJP? Do you agree that it's at least important to know reflection as threads? Thanks for any answer

    Read the article

  • New Enhanced Visual WebGui WINWEB and .NETHTML5 Versions

    - by Webgui
    After a long wait and huge anticipation from the Visual WebGui community, I am happy to announce the release of new versions for the WINWEB and .NETHTML5 branches. The new 6.4.0 Release d and 6.4.0 beta3 versions are available after an extensive work on core capabilities of Visual WebGui including extension of existing controls and adding new controls such as Strip Controls, RibbonBar, DataGridView, ComboBox, PropertyGrid and RadioButton, DataGridView, ComboBox, PropertyGrid and RadioButton, as well as some major enhancements to both versions in terms of cross-browser support and performance.We apologize for the delay in the release of those most expected versions, but we believe that the extra time lead to a more mature and complete product. As you can see the changelog is pretty long and includes a list of enhancements, new features and bug fixes: http://visualwebgui.com/Developers/KB/tabid/654/article/w_changelogs/Default.aspx The new versions are available for all versions with open source and for The new versions are available for all versions with open sources for Visual Studio 2005, 2008 and 2010. You are welcome to download the WINWEB Free Trial and the Free .NETHTML5 beta on the downloads page.

    Read the article

  • weblogs.asp.net! I am here now!

    - by kaushalparik27
    Hello all webloggers!! Finally after much wait I got my blog space approved here. I really want to thank moderators (specially Terry for mail follow up) helping me out creating my weblog here. I; usually; blog about things and situation that I come across while development or something on which I succeeded to have some study/reading. Till now, I was maintaining my blog here (which I am still going to maintain in future as well!). Wishing for the best and thanks all future readers!

    Read the article

  • Ubuntu Server 12.04 Screen Resolution "Out of Range"

    - by Alastair Mackie
    I'm fairly new to ubuntu and have just installed Ubuntu Server 12.04 on a spare machine to experiment and play with! The installation went without problem, however whenever the OS boots the monitor displays a an error message saying the resolution is "out of range" and i can't see to do anything - i can wait as long as i like, but nothing appears. Ubuntu is the only OS installed so bypasses GRUB on boot, although the GRUB screen is also out of range if forced on startup. I can access a shell from the recover mode and i can get at a terminal through a LiveCD of the Desktop version but have had little luck with either. I've been trying to figure this out for days and i'm at a total loss. Any thoughts?

    Read the article

  • Motorola India meets Mayan calender dead line – earlier than predicted

    - by Boonei
    My favorite cell phone maker Moto is closing it doors in India. Plan is to  have their service shops open. If you still want to grab the last living decendent of the phone in India there is good news “would continue to sell its phones till stocks are exhausted while service centers would continue to function”. Ya !  lock up in your safe, wait 20 years, then sell this antique for a fortune. There is will be staff cut and Moto promised to help employees at these difficult times. India is one of the most sort out market for mobile makers, what is running in Googles mind ? May be world is falling apart like Mayans predicted ?    

    Read the article

  • In the context of semantic versioning, does a change in the default configuration warrant a new major version?

    - by michielvoo
    My module is enabled by default (i.e. when you add the module). There's also a configuration you can optionally use, which supports an enabled="true|false" setting. This way the module can be disabled after it's been added, without the need to remove the module. But I realized the module doesn't play nicely with another module that is also enabled by default. I am considering changing my module so it's not be enabled by default. This would break for anyone that has not explicitly enabled it with the enabled="true" configuration setting. Should I wait for v2.0 for this? semver.org mentions the public API and breaking changes, not configuration. Is it generally accepted that configuration is part of the public API?

    Read the article

  • Session Mania: Content Catalog & Suggest-a-Session

    - by Justin Kestelyn
    As ably reported in the Oracle Technology Network blog, the Oracle Develop Conference's content catalog is now public (as are the catalogs for JavaOne and Oracle OpenWorld), meaning you can now explore technical sessions scheduled for the conf to your heart's content."But something's missing", you may tell yourself. "Where is my favorite subject, the one I happen to also be an expert on?" Well, there's good news for you, too: The Suggest-A-Session project has returned. It works thus: Submit a session idea via Oracle Mix and ask your colleagues, Oracle Mix community, friends and anyone else you know to vote for your session. (You must be an Oracle Mix member to vote.) Voting is open through June 20. For the most part, the top voted sessions will be selected for the Oracle Develop Conf (or Oracle OpenWorld) official agenda. See the FAQ for fine print.Apparently some people have already jumped into this loophole, including Oracle ACE Director Marco Gralike, who has "gone video" on us: Why wait? Suggest-a-session!

    Read the article

  • VS2010 crashes when opening a vsp generated using VS 2012

    - by Tarun Arora
    I recently profiled some web applications using Visual Studio 2012, a vsp (Visual Studio Profile) file was generated as a result of the profiling session. I could successfully open the vsp file in Visual Studio 2012 as expected but when I tried to open the vsp file in Visual Studio 2010 the VS2010 IDE crashed. As a responsible citizen I raised bug # 762202 on Microsoft Connect site using the Microsoft Visual Studio 2012 Feedback Client. Note – In case you didn’t already know, VSP generated in Visual Studio 2012 is not backward compatible. Please refer below for the steps to reproduce the issue and the resolution of the connect bug. 1. Behaviour and Steps to Reproduce the Issue Description I have generated a vsp file by using the Visual Studio 2012 Standalone profiler. When I try and open the vsp file in Visual Studio 2010 the IDE crashes. I understand that a vsp generated by using VS 2012 cannot be opened in VS 2010, but the IDE crashing is not the behaviour I would expect to see. Steps to Reproduce the Issue 1. Pick up the Stand lone profiler from the VS 2012 installation media. The folder has both x 64 and x86 installer, since the machine I am using is x64 bit. I have installed the x64 version of the standalone profiler. 2. I have configured the system path by setting the 'environment variable' path to where the profiler is installed. In my case this is, C:\Program Files (x86)\Microsoft Visual Studio 11.0\Team Tools\Performance Tools 3. Created a new environment variable _NT_SYMBOL_PATH and set its value to CACHE*C:\SYMBOLSCACHE;SRV*C:\SYMBOLSCACHE*HTTP://MSDL.MICROSOFT.COM/DOWNLOAD/SYMBOLS;\\FOO\BUILD1234 4. Open up CMD as an administrator and run 'VSPerfASPNETCmd /tip http://localhost:56180/ /o:C:\Temp\SampleEISK.vsp' 5. This generates the following message on the cmd       Microsoft (R) VSPerf ASP.NET Command, Version 11.0.0.0     Copyright (C) Microsoft Corporation. All rights reserved.     Configuring and attaching to ASP.NET process. Please wait.     Setting up profiling environment.     Starting monitor.     Launching ASP.NET service.     Attaching Monitor to process.     Launching Internet Explorer.     The profiler is attached to ASP.net. Please run your application scenario now.     Press Enter to stop data collection...   6. I perform certain actions and then I come back to the cmd and hit enter to shut down the profiling. Once I do this, the following message is written to the cmd, Press Enter to stop data collection... Profiling now shut down. Report file "C:\Temp\SampleEISK.vsp" was generated. Running VsPerfReport, packing symbols into the .VSP. Shutting down profiling and restarting ASP.NET. Please wait. Restarting w3wp.exe.   7. I look in the C:\Temp folder and I can see the SampleEISK.vsp file generated. I can successfully open this file in Visual Studio 2012. 8. When I am trying to open the vsp file in VS 2010 the VS 2010 IDE crashes. Kaboooom! What I would expect to happen I expect to receive a message "VS 2010 does not support the vsp file generated by VS 2012". What actually happened The VS 2010 IDE crashed 2. Resolution This is a valid bug! However, there isn’t much value in releasing a hotfix for this issue. Refer below to the resolution provided by the Visual Studio Profiler Team.  Thank you for taking the time to report this issue. We completely agree that Visual Studio 2010 should not crash. However in this particular case this is not a bug we are going to retroactively release a fix to 2010 for at this point. Given that a fix would not unblock the scenario of opening a 2012 created file on Visual Studio 2010, and there is not an active update channel for Visual Studio 2010 other than manually locating and installing hot fixes, we will not be fixing this particular issue. Best Regards, Visual Studio Profiler Team   Though it would be great to improve the behaviour however, this is not a defect that would stop you from progressing in any way. It’s important to note however that VSP files generated by Visual Studio 2012 are not backward compatible so you should refrain from opening these files in Visual Studio 2010.

    Read the article

  • Moving from one DNS provider to another

    - by Senthil Kumaran
    I had registered with a particular DNS provider X and I have been unhappy with their services and now when the time for renewal came, I did not renew and I let it expire. I am hoping that once it is expired from this provider, I would be able to sign up for the same domain name from an alternative provider which I have tested and I am satisfied. What kind of precautions should I take? The domain name is not a critical one, it is of a NGO and we prefer to own it again without any change in the name. The information given by the expiry notice says Domains can be renewed between 90 days before and 14 days after the expiry date. If domains are not renewed they will be removed from the account and set for deletion. Should I wait for time till gets deleted at their end so that I can sign up for the same from another provider?

    Read the article

  • C#4: Why does this static field always get initialized over-eagerly?

    - by TheSilverBullet
    I am looking at this excellent article from Jon Skeet at this location: http://csharpindepth.com/Articles/General/Beforefieldinit.aspx While executing the demo code, Jon Skeet says that we can expect three different kinds of behaviours. To quote that article: The runtime could decide to run the type initializer on loading the assembly to start with... Or perhaps it will run it when the static method is first run... Or even wait until the field is first accessed... When I try this out (on framework 4), I always get the first result. That is, the static method is initialized before the assembly is loaded. I have tried running this multiple times and get the same result. (I tried both the debug and release versions) Why is this so? Am I missing something?

    Read the article

  • System unable to boot in normal mode..! need to select recovery mode and than Generic Mode to boot.?

    - by Haresh Veera
    I am using Ubuntu Server 12.04 LTS KDE Mode. Couple of Days back I updated the system using Muon Package manager. After Updating, now when ever I boot the system, It get stuck at starting bluetooth Daemon Ok / Stopping Bluetooth Daemon Fail.and after long wait its get start to GUI Mode, but with no mouse detection. So need to reboot by pressing CTL+ALT+DEL and when I select recovery mode - Boot in Generic -- It boot perfectly. How can I set the same as default, and remove the error boot loader script. I am no expert to linux or Kernel.

    Read the article

  • Asynchronous update design/interaction patterns

    - by Andy Waite
    These days many apps support asynchronous updates. For example, if you're looking at a list of widgets and you delete one of them then rather than wait for the roundtrip to the server, the app can hide the one you deleted, giving immediate feedback. The actual deletion on the server will happen in the background. This can be seen in web apps, desktop apps, iOS apps, etc. But what about when the background operation fails. How should you feed back to the user? Should you restore the UI to the pre-deletion state? What about when multiple background operations fail together? Does this behaviour/pattern have a name? Perhaps something based on the Command pattern?

    Read the article

  • Tip #15: How To Debug Unit Tests During Maven Builds

    - by ByronNevins
    It must be really really hard to step through unit tests in a debugger during a maven build.  Right? Wrong! Here is how i do it: 1) Set up these environmental variables: MAVEN_OPTS=-Xmx1024m -Xms256m -XX:MaxPermSize=512mMAVEN_OPTS_DEBUG=-Xmx1024m -Xms256m -XX:MaxPermSize=512m  -Xdebug (no line break here!!)  -Xrunjdwp:transport=dt_socket,server=y,suspend=y,address=9999MAVEN_OPTS_REG=-Xmx1024m -Xms256m -XX:MaxPermSize=512m 2) create 2 scripts or aliases like so:  maveny.bat: set MAVEN_OPTS=%MAVEN_OPTS_DEBUG% mavenn.bat: set MAVEN_OPTS=%MAVEN_OPTS_REG%    To debug do this: run maveny.bat run mvn install attach your debugger to port 9999 (set breakpoints of course) When maven gets to the unit test phase it will hit your breakpoint and wait for you. When done debugging simply run mavenn.bat Notes If it takes a while to do the build then you don't really need to set the suspend=y flag. If you set the suspend=n flag then you can just leave it -- but only one maven build can run at a time because of the debug port conflict.

    Read the article

  • Thread.Interrupt Is Evil

    - by Alois Kraus
    Recently I have found an interesting issue with Thread.Interrupt during application shutdown. Some application was crashing once a week and we had not really a clue what was the issue. Since it happened not very often it was left as is until we have got some memory dumps during the crash. A memory dump usually means WindDbg which I really like to use (I know I am one of the very few fans of it).  After a quick analysis I did find that the main thread already had exited and the thread with the crash was stuck in a Monitor.Wait. Strange Indeed. Running the application a few thousand times under the debugger would potentially not have shown me what the reason was so I decided to what I call constructive debugging. I did create a simple Console application project and try to simulate the exact circumstances when the crash did happen from the information I have via memory dump and source code reading. The thread that was  crashing was actually MS code from an old version of the Microsoft Caching Application Block. From reading the code I could conclude that the main thread did call the Dispose method on the CacheManger class which did call Thread.Interrupt on the cache scavenger thread which was just waiting for work to do. My first version of the repro looked like this   static void Main(string[] args) { Thread t = new Thread(ThreadFunc) { IsBackground = true, Name = "Test Thread" }; t.Start(); Console.WriteLine("Interrupt Thread"); t.Interrupt(); } static void ThreadFunc() { while (true) { object value = Dequeue(); // block until unblocked or awaken via ThreadInterruptedException } } static object WaitObject = new object(); static object Dequeue() { object lret = "got value"; try { lock (WaitObject) { } } catch (ThreadInterruptedException) { Console.WriteLine("Got ThreadInterruptException"); lret = null; } return lret; } I do start a background thread and call Thread.Interrupt on it and then directly let the application terminate. The thread in the meantime does plenty of Monitor.Enter/Leave calls to simulate work on it. This first version did not crash. So I need to dig deeper. From the memory dump I did know that the finalizer thread was doing just some critical finalizers which were closing file handles. Ok lets add some long running finalizers to the sample. class FinalizableObject : CriticalFinalizerObject { ~FinalizableObject() { Console.WriteLine("Hi we are waiting to finalize now and block the finalizer thread for 5s."); Thread.Sleep(5000); } } class Program { static void Main(string[] args) { FinalizableObject fin = new FinalizableObject(); Thread t = new Thread(ThreadFunc) { IsBackground = true, Name = "Test Thread" }; t.Start(); Console.WriteLine("Interrupt Thread"); t.Interrupt(); GC.KeepAlive(fin); // prevent finalizing it too early // After leaving main the other thread is woken up via Thread.Abort // while we are finalizing. This causes a stackoverflow in the CLR ThreadAbortException handling at this time. } With this changed Main method and a blocking critical finalizer I did get my crash just like the real application. The funny thing is that this is actually a CLR bug. When the main method is left the CLR does suspend all threads except the finalizer thread and declares all objects as garbage. After the normal finalizers were called the critical finalizers are executed to e.g. free OS handles (usually). Remember that I did call Thread.Interrupt as one of the last methods in the Main method. The Interrupt method is actually asynchronous and does wake a thread up and throws a ThreadInterruptedException only once unlike Thread.Abort which does rethrow the exception when an exception handling clause is left. It seems that the CLR does not expect that a frozen thread does wake up again while the critical finalizers are executed. While trying to raise a ThreadInterrupedException the CLR goes down with an stack overflow. Ups not so nice. Why has this nobody noticed for years is my next question. As it turned out this error does only happen on the CLR for .NET 4.0 (x86 and x64). It does not show up in earlier or later versions of the CLR. I have reported this issue on connect here but so far it was not confirmed as a CLR bug. But I would be surprised if my console application was to blame for a stack overflow in my test thread in a Monitor.Wait call. What is the moral of this story? Thread.Abort is evil but Thread.Interrupt is too. It is so evil that even the CLR of .NET 4.0 contains a race condition during the CLR shutdown. When the CLR gurus can get it wrong the chances are high that you get it wrong too when you use this constructs. If you do not believe me see what Patrick Smacchia does blog about Thread.Abort and List.Sort. Not only the CLR creators can get it wrong. The BCL writers do sometimes have a hard time with correct exception handling as well. If you do tell me that you use Thread.Abort frequently and never had problems with it I do suspect that you do not have looked deep enough into your application to find such sporadic errors.

    Read the article

< Previous Page | 105 106 107 108 109 110 111 112 113 114 115 116  | Next Page >