Search Results

Search found 73059 results on 2923 pages for 'system string'.

Page 1126/2923 | < Previous Page | 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133  | Next Page >

  • graphic error on console

    - by Christian Elsner
    I have Linux on an embedded system. There is no graphic system, but I still have graphic errors. For example, if I type: ifconfig eth2 hw ether 00:0e:8c:d0:59:d2 I see: ifconfig eth hw ether 00:0e:8:2:2 If I type Enter, it accepts the command I typed, so it's just a matter of displaying. Everything is fine, when I log in via SSH. Anyone any ideas, what could be the cause or where to look at? Output of lspci: 00:00.0 Host bridge: Intel Corporation 3100 Chipset Memory I/O Controller Hub 00:00.1 Unassigned class [ff00]: Intel Corporation 3100 DRAM Controller Error Reporting Registers 00:01.0 System peripheral: Intel Corporation 3100 Chipset Enhanced DMA Controller 00:02.0 PCI bridge: Intel Corporation 3100 Chipset PCI Express Port A 00:03.0 PCI bridge: Intel Corporation 3100 Chipset PCI Express Port A1 00:1c.0 PCI bridge: Intel Corporation 631xESB/632xESB/3100 Chipset PCI Express Root Port 1 (rev 01) 00:1c.1 PCI bridge: Intel Corporation 631xESB/632xESB/3100 Chipset PCI Express Root Port 2 (rev 01) 00:1d.0 USB Controller: Intel Corporation 631xESB/632xESB/3100 Chipset UHCI USB Controller #1 (rev 01) 00:1d.1 USB Controller: Intel Corporation 631xESB/632xESB/3100 Chipset UHCI USB Controller #2 (rev 01) 00:1d.7 USB Controller: Intel Corporation 631xESB/632xESB/3100 Chipset EHCI USB2 Controller (rev 01) 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev c9) 00:1f.0 ISA bridge: Intel Corporation 631xESB/632xESB/3100 Chipset LPC Interface Controller (rev 01) 00:1f.2 IDE interface: Intel Corporation 631xESB/632xESB/3100 Chipset SATA IDE Controller (rev 01) 00:1f.3 SMBus: Intel Corporation 631xESB/632xESB/3100 Chipset SMBus Controller (rev 01) 02:00.0 Ethernet controller: Intel Corporation 82574L Gigabit Network Connection 03:01.0 Network controller: Siemens Nixdorf AG Device 4003 (rev 02) 03:01.1 Unassigned class [ff00]: Siemens Nixdorf AG Device 4003 (rev 02) 03:02.0 Ethernet controller: Siemens Nixdorf AG Device 4047 (rev 01) 03:03.0 Ethernet controller: National Semiconductor Corporation DP83815 (MacPhyter) Ethernet Controller 03:04.0 Unassigned class [ff00]: Siemens Nixdorf AG Device 4057 (rev 01) 04:00.0 PCI bridge: Texas Instruments XIO2000(A)/XIO2200(A) PCI Express-to-PCI Bridge (rev 03) 05:00.0 Ethernet controller: Advanced Micro Devices [AMD] 79c970 [PCnet32 LANCE] (rev 44) 06:00.0 PCI bridge: Texas Instruments XIO2000(A)/XIO2200(A) PCI Express-to-PCI Bridge (rev 03) 07:00.0 VGA compatible controller: Silicon Motion, Inc. SM720 Lynx3DM (rev c1) 07:01.0 USB Controller: NEC Corporation USB (rev 43) 07:01.1 USB Controller: NEC Corporation USB (rev 43) 07:01.2 USB Controller: NEC Corporation USB 2.0 (rev 04) The whole thing is running on an Intel Core 2 Duo U2500

    Read the article

  • HDMI Sound for HTPC

    - by Brent Arias
    I have the (perhaps) the same problem as stated in this other HDMI sound to HTPC question. I tried the advice of clicking on the speaker in the system tray. I can see the HDMI audio device I want to use. That device claims to be functioning properly. But there is no sound, and it won't let me select it as the active audio device. When I click on the troubleshooter, it says that there are no speakers connected. I would think this is because my computer us unable to pipe sound through the video card (preventing the HDMI from carrying it), except that it truly claims that it has an HDMI sound device that is working correctly. So I'm not sure what is wrong at this point. Thoughts? My system is Windows 7 x64. In case it makes a difference, the video card I'm using is this GeForce GTX 560

    Read the article

  • Windows 7 sata disk not recognized after wake up from sleep state

    - by Gabber
    My windows 7 x64 PC/server worked fine until I installed a brand new seagate SATA hard disk (2 TB). My first disk was a IDE Maxtor (250 GB). I tried to use it as a secondary drive leaving the maxtor as primary and, when I put the computer in sleep state, on wake-up the SATA disk is not recognized anymore until next reboot. Now I'm trying to set it as primary disk (I copied the old HD contents with HD clone), when the computer goes in sleep state, on wake up it doesn't see the disc thus causing my system to crash. I tried the following: BIOS update (Asus M2V motherboard) but the situation worsened as the system didn't wake up from the sleep (with both my HD's) Reinstalling the drivers Bios changes Microsoft Hotfix KB977178 that seemed to address exactly my problem but gave me "The update is not applicable to your computer" message. Disabling hybrid sleep but no results. I also tried all the suggestions from this question Why doesn't Windows 7 wake up from sleep?. Still no results.

    Read the article

  • CentOS Live CD Creation issues

    - by Dheeraj
    I am creating my customized CentOS 6.3 Live CD. I am following information given at https://projects.centos.org/trac/livecd/wiki/GetToolset My "livecd-creator" command completes successfully and an ISO image is created. But when I try to boot up my system with this ISO, it goes up to the CentOS blue screen and then the CAPS lock and Scroll Lock LEDs on the keyboard starts flashing. Then from here after, the system takes no input from keyboard and I have to power cycle it and it does the same thing. Could you get me any suggestion why this is causing and possible workaround. Thanks.

    Read the article

  • How to build compass in sublime text 2

    - by aurel
    I downloaded this package which allows use to build compass in though sublime text by pressing cmd+b. I created a sass file, made sure compass is selected from the tools build system compass menu. But when I press cmd+b the file does not compile and I get no error. I only get [Finished in 0.0s with exit code 1]. However I also tested to build the code with sass (tools build system sass) and it works fine. Do I need to do anything to the sass file for compass to work. Thanks

    Read the article

  • Emulating CP/M under Linux

    - by gh403
    I need to be able to run a very old piece of software -- the HI-TECH z80 C Compiler for CP/M. It has been released as freeware by HI-TECH. Alas, it only runs on CP/M. After a lot of Googling, I found a page of utilities for UZIX. One of those utilities is a script to abstract away the emulation of a CP/M machine, thus allowing you to use the compiler as you would any other UNIX program. The problem with this script is that it depends on their own CP/M emulator, which unfortunately will not compile on a modern (x64) system. My question: is there a usable CP/M emulator for Linux that could be used in a similar fashion? Specifically, I need to be able to somehow have it access files from the host system, a la DOSBox. I'm willing to rewrite a script (I don't have to re-use the UZIX one); I just need an emulator. Thanks for any help!

    Read the article

  • Insert Hyperlink via VBA

    - by Martin
    I have a Word VBA macro that loops through a directory and writes down the file path of files selected for some criteria into a new Word document. Works well as plain text (as part of a loop): wdDocResults.Content.InsertAfter objFile.Path & Chr(13) However, I'd like them to be hyperlinks. The following works as single macro, but when called from within another script, it does nothing at all (no matter if path is provided as variable or string, or as H:... or \\MyServernameAsNetDrive...): ActiveDocument.Hyperlinks.Add Anchor:=Selection.Range, Address:= objFile.Path, _ SubAddress:="", ScreenTip:="", TextToDisplay:=objFile.Path If try to select the current line in order to make sure something is selected at the right place -- error: out of memory": wrdDocResults.Content.InsertAfter objFil.Path Selection.Expand wdLine ActiveDocument.Hyperlinks.Add Anchor:=Selection.Range, Address:= objFile.Path, _ SubAddress:="", ScreenTip:="", TextToDisplay:=objFile.Path I also tried inserting a string resembling the Hyperlink field code ({ Hyperlink "..." }, which is of course not recognized... Any help is appreciated... Thanks in advance!

    Read the article

  • Few questions about SLI

    - by toomanyairmiles
    Hi all, thanks in advance for your help. I've just added a second card to my system so I can add a third monitor. I'd got as far as determining both cards need to use the same driver (after a blind alley with another cheap ATi card) so I'm now the proud owner of a second BFG 9800 GTX+ card. One is a BFG OCX and the other an BFG OC (small difference in clock speeds but they are in all other respects the same) but wanted to know the following:- 1) Is it worth adding the SLI connector, will it really boost overall performance (I'm guessing that the OCX card will then perform as the OC card does)? 2) Are SLI connectors (the one's that run across the top of the cards) motherboard or manufacturer specific? 3) If I do SLI the cards will I still be able to use all four monitor connectors or just the two on the master card? I'm not a gamer, I'm an IA and web designer so the system is mostly for Photoshop and Illustrator work and the occasional knock around in command and conquer.

    Read the article

  • Connect to wired and wireless networks at same time, Ubuntu

    - by Gary Chambers
    Currently, I have a media PC running Ubuntu 10.04 that I am trying to connect via a wired network cable directly to a NAS box, and wirelessly to the router. This works no problem after I run sudo /etc/init.d/networking restart but I can't get both interfaces to come up on system startup. My /etc/network/interfaces file reads as follows: auto eth0 iface eth0 inet static address 10.0.1.2 netmask 255.255.254.0 broadcast 10.0.1.255 network 10.0.1.0 auto wlan2 iface wlan2 inet dhcp As I say, I know this works, because I can get it to work by restarting the network interfaces, but I can't bring them both up on system startup. Does anyone know why this might be?

    Read the article

  • NT4 server generate too much weird DNS queries, How can i see the source PID?

    - by Hanan N.
    I have a NT4 server that in the last two weeks started to generate too many weird DNS queries to the DNS server is set to use. I have got warnings from the IPS system that it has blocked the responses from the DNS server back to the NT4 server. The queries it generate doesn't relate to any computer in the network, it is like 120624100088.xxxxxxx.net where xxx is the internal network, the numbers are just random at each query. I have done some research on how to get the PID that is generating the queries, and i found that only Process Monitor could give me that information, but since it is NT4 system Process Monitor doesn't work on it. It is a production server and i am just can't stop services as i want. I would like to get your advice on how can i get the PID that is generating these queries? Thanks.

    Read the article

  • Mac OS X Server 10.6.6 "disables" CPU in VMware Fusion

    - by wjlafrance
    Hello! I installed Mac OS X Server 10.6.0 in VMWare Fusion the other night and it worked perfectly, until I ran Software Update. I upgraded to 10.6.6 through the combo updater, and now when I start the VM it says: "The CPU has been disabled by the guest operating system. You will need to power off or reset the virtual machine at this point." I've switched the operating system in the options to OS X Server 32bit, 64bit, and even to Windows 7, and nothing has worked. Does anyone have any ideas?

    Read the article

  • Webcam microphone input in Gnome/pulseaudio

    - by sdaau
    Just got a "Trust" webcam, which gets recognized on my Ubuntu Lucid. It has a built in microphone - which also gets recognized - however, I cannot really get it to act as the system microphone input? Here are some screenshots of what is shown by gnome-volume-control: The default window shows Trust webcam - which has two profiles: "Analog Mono Input" and "Off" - of course, I have it on "Analog Mono Input": However, on the "Input" tab - there is no matching "device for sound input" - neither a matching connector: Then I installed pavucontrol - but that doesn't show that much more; it tells first that gnome-volume-control reads from "Internal Audio Analog Stereo": Then in "Input devices" tab, there is again nothing resembling the mic input from webcam: Finally, under "Configuration" tab, the "Trust" webcam shows, but even if its profile is on "Analog Mono Input", nothing much happens:   So, does anyone know how I could get this webcam microphone to be recognized as the system input? Many thanks in advance for any answers, Cheers!

    Read the article

  • Client-based program to track response time for online webservice

    - by Søren Haagerup
    I am helping a customer with general IT support, and they have a problem with a hosted web-based system being slow. The provider of the system blames the client's computer, and the client calls me for help. I blame the provider, but it is hard to get them to do something about it without rock-solid evidence. And every time the provider comes around for a TeamViewer session, everything of course runs smoothly. Does there exist a client program or browser plugin that tracks statistics about response time for specific web services?

    Read the article

  • networked storage for a research group, 10-100 TB

    - by Marc
    this is related to this post: http://serverfault.com/questions/80854/scalable-24-tb-nas-for-research-department but perhaps a little more general. Background: We're a research lab of around 10 people who do a lot of experiments that involve taking pictures at one of several lab setups and then analyzing it an one of several lab computers. Each experiment may produce 2 or 3 GB of data, and we are generating data at the rate of about 10 TB/year. Right now, we are storing the data on a 6-bay netgear readynas pro, but even with 2 TB drive, this only gives us 10 TB of storage. Also, right now we are not backing up at all. Our short term backup plan is to get a second readynas, put it in a different building and mirror the one drive onto the other. Obviously, this is somewhat non-ideal. Our options: 1) We can pay our university $400/ TB /year for "backed up" online storage. We trust them more than we trust us, but not a whole lot. 2) We can continue to buy small NASs and mirror them between offices. One limit, although stupid, is that we don't have an unlimited number of ethernet jacks. 3) We can try to implement our own data storage solution, which is why I'm asking you guys. One thing to consider is that we're a very transient population and none of us are network administration experts. I will probably be here only another year or so, and graduate students, who are here the longest, have a 5-6 year time scale. So nothing can require expert oversight. Our data transfer rates are low - most of the data will just sit on the server waiting for someone to look at it once or twice - so we don't need a really high speed system. Given these contraints, can someone recommend a fairly low-cost, scalable, more or less turn key shared data storage system with backup in a separate physical location. Does such a thing exist or should we just pay the university to take care of it for us? As a second question, our professor just got tenure and is putting together a budget. Here the goal is to ask for as much as you can and hope you get a fraction of it. So the same question, minus the low-cost. Without budget constraints, can you recommend a scalable turn-key backed up storage system. Thanks

    Read the article

  • Color Calibrate Dual Monitor XP SP2

    - by Laramie
    This topic has been touched on before but not really answered. I have a dual monitor system and the colors differ wildly. I currently live Buenos Aires where color correction hardware costs premium prices. I do some graphic design, but don't require a pro-level calibration. That said, I'd like my monitors to be set as close to "true color" as possible. I've located the useful and free Monitor Calibration Wizard, but it seems to adjust the entire system internally at startup. I could use the Microsoft Color Control Panel Applet to set a different ICC or ICM profile for each monitor, but the Monitor Calibration Wizard outputs its own format for profiles.

    Read the article

  • Configuring BitLocker on existing Windows Server 2008

    - by neildeadman
    On our file server, we want to enable BitLocker so that we can encrypt a single drive and I know that we have to also encrypt the drive the system is installed on. In my tests with VMs, I have to create a partition on the same disk as Windows is installed either before I install Windows or after (I can use the BitLocker Drive Preparation Tool). This tool shrinks the C: drive to make way for a 1.5GB partition. I'm a little concerned about doing this with a live system so wanted to see if it was possible to get BitLocker to use a partition on another drive?

    Read the article

  • Dell PowerEdge R720 - Corrupted RAID

    - by BT643
    Apologies in advance for the lengthy question. We have a Dell PowerEdge R720 server with: 2 x 136GB SAS drives in RAID 1 for the OS (Ubuntu Server 12.04) 6 x 3TB SATA drives in RAID 5 for data A few days ago we were getting errors when trying to access files on the large RAID 5 partition. We rebooted the server and got a message about the raid controller has found a foriegn config. We've had this before, and just needed to use Dell's RAID configuration utility to import foreign config on the RAID. Last time this worked, but this time, it started doing a disk check then we got this: FSCK has returned the following: "/dev/sdb1 inode 364738 has a bad extended attribute block 7 /dev/sdb1 unexpected inconsistency run fsck manually (i.e without -a or -p options) MOUNTALL fsck /ourdatapartition [1019] terminated with status 4 MOUNTALL filesystem has errors /ourdatapartition errors where found while checking the disk drive for /ourdatapartition Press F to fix errors, I to Ignore or M for Manual Recovery" We pressed F to try and fix the errors, but it eventually errored with: Inode 275841084, i_blocks is 167080, should be 0. Fix? yes Inode 275841141 has an invalid extend node (blk 2206761006, lblk 0) Clear? yes Inode 275841141, i_blocks is 227872, should be 0. Fix? yes Inode 275842303 has an invalid extend node (blk 2206760975, lblk 0) Clear? yes .... Error storing directory block information (inode=275906766, block=0, num=2699516178): Memory allocation failed /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** e2fsck: aborted /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** mountall: fsck /ourdatapartition [1286] terminated with status 9 mountall: Unrecoverable fsck error: /ourdatapartition We noticed one of the drive lights was not lit at all, and thought this may have failed and be the problem. We replaced the drive with a spare, and tried "F" to repair it again, but we keep just getting the same error as above. In the RAID configuration utility, all drives show as "online" and "optimal". We do have this data on another replicated server, so we're not worried about "recovering" anything, we just want to get the system back online asap. The server has 64 or 32GB memory, can't remember off the top of my head, but either way, with a 14TB RAID, I think it may still not be enough. Thanks EDIT - I checked the memory usage while fsck was running as suggested and after 2 or 3 minutes, it looked like this, using up nearly all of our servers memory: When it failed after 5 minutes or so with the error in my post, the memory immediately freed up again:

    Read the article

  • OS2/Warp - Remotely Stop and Restart a Program

    - by Justin S
    Our current phone system runs off of a legacy OS2/Warp box. Periodically we have to log into the machine and restart OS2RSD.exe and then start it again and the phone system starts working again. The problem is we have to physically get in front of the box and use the GUI to stop and restart the process. Is it possibly to remotely run a script to kill OS2RSD.exe if its running and then start it again? I have been unable to figure this out on my own. The OS is OS2/Warp Version 3 if that helps.

    Read the article

  • Linux-Vserver: How to do upgrade Debian 5.0 to 6.0 on vservers and main machine?

    - by Bartosz Kowalczyk
    I have server with debian lenny. I installed vserver on this server a few years ago. Summary I have 5 guest of vservers and main system, now. Each guest is debian lenny. Now, I'm wanting upgrade from lenny to squeezy on this servers (each Vservers and main machine). Do you do it? I should upgrade as usually system ? First I should upgrade every vserver next main machines and I have to do reset all machines and vservers? Please, advise me how to do it ?

    Read the article

  • Thermal risks to other components when watercooling CPU

    - by B Sharp
    I recently ordered all the components for a new desktop system to replace my old, dying computer. I wanted to have a really quiet desktop, so I got a case rated for being quiet and opted to try a closed-system CPU water cooling kit (Antec Kuhler H2O 620) that was on sale for a very good price over the Thanksgiving weekend. Most of my components are still in transit, but I became somewhat worried when a friend mentioned that abandoning air cooling units can result in heat buildup inside the case due to heat generated by the video card and other components such as RAM, the northbridge, MOSFETs and voltage regulators radiating heat that the CPU fan would normally at least keep circulating around so it doesn't build up in localized areas. Is this a realistic problem? What other precautions should I take to remove heat from other components? Adding more case fans seems like it would get really noisy. Are there quiet alternatives?

    Read the article

  • Shared storage solution for our sql server backups

    - by Gokhan
    We have 3 clustered sql servers. We have 5+ multi terrabyte databases and their backup files (compressed using quest litespeed) are hitting over 600gb each, We are required to keep at least a week or two weeks (if we can) of weekly full backups and then 6 days differential backups, and a week or 2 weeks worth of log backups local. We are currently limited to 2TB volumes from our san team, we can have multiple volumes but they are expensive ($200 per raw TB per month) and having to deal with many backup volumes instead of a single big volume is difficult. I think if we could have a shared network storage of 20TB+ raid 10 or so for all our servers for keeping the backups and another department will copy them to tape from the network storage and delete files according to the retention period would be good, if this box would be a build in operating system (even unix a complete file storage system) that would be good. What do you guys think, does this make sense to you, is there any manufacturer that sells a storage product like that which that work in a clustered environment? Thank you

    Read the article

  • Windows 7 sata disk not recognized after wake up from sleep state [closed]

    - by Gabber
    My windows 7 x64 PC/server worked fine until I installed a brand new seagate SATA hard disk (2 TB). My first disk was a IDE Maxtor (250 GB). I tried to use it as a secondary drive leaving the maxtor as primary and, when I put the computer in sleep state, on wake-up the SATA disk is not recognized anymore until next reboot. Now I'm trying to set it as primary disk (I copied the old HD contents with HD clone), when the computer goes in sleep state, on wake up it doesn't see the disc thus causing my system to crash. I tried the following: BIOS update (Asus M2V motherboard) but the situation worsened as the system didn't wake up from the sleep (with both my HD's) Reinstalling the drivers Bios changes Microsoft Hotfix KB977178 that seemed to address exactly my problem but gave me "The update is not applicable to your computer" message. Disabling hybrid sleep but no results.

    Read the article

  • Transferring DHCP using Windows Server Migration Tool - Why is Powershell is crashing on the import of the .mig file?

    - by Mike
    I am migrating DHCP from a windows server 2003R2 DC to a Windows Server 2008R2 DC I've followed this video and its predecessor (Installing Windows Server Migration Tools) http://technet.microsoft.com/en-us/video/migrating-dhcp-using-the-windows-server-2008-r2-migration-tools.aspx I went through everything smoothly until the last step. I have exported a .mig file with my DHCP configuration on the old 2003r2 server. I transferred this .mig file over to my 2008R2 server, when running the import command, it will appear to work for a minute or two and then I get a generic windows "Powershell has stopped working" error and I have to close the program. Under the problem details I see the following: FileVersionOfSystemManagementAutomation: 6.1.7600.16385 InnermostExceptionType: System.AccessViolationException OutermostExceptionType: System.AccessViolationException DeepestPowerShellFrame: unknown OS Version: 6.1.7600.2.0.0.272.7 LocaleID: 1033 Seems like there are permissions issues maybe? I am running powershell as an admin and am logged in to the server as a domain administrator. Any Ideas? Thanks

    Read the article

  • How can a single disk in a hardware SATA RAID-10 array bring the entire array to a screeching halt?

    - by Stu Thompson
    Prelude: I'm a code-monkey that's increasingly taken on SysAdmin duties for my small company. My code is our product, and increasingly we provide the same app as SaaS. About 18 months ago I moved our servers from a premium hosting centric vendor to a barebones rack pusher in a tier IV data center. (Literally across the street.) This ment doing much more ourselves--things like networking, storage and monitoring. As part the big move, to replace our leased direct attached storage from the hosting company, I built a 9TB two-node NAS based on SuperMicro chassises, 3ware RAID cards, Ubuntu 10.04, two dozen SATA disks, DRBD and . It's all lovingly documented in three blog posts: Building up & testing a new 9TB SATA RAID10 NFSv4 NAS: Part I, Part II and Part III. We also setup a Cacit monitoring system. Recently we've been adding more and more data points, like SMART values. I could not have done all this without the awesome boffins at ServerFault. It's been a fun and educational experience. My boss is happy (we saved bucket loads of $$$), our customers are happy (storage costs are down), I'm happy (fun, fun, fun). Until yesterday. Outage & Recovery: Some time after lunch we started getting reports of sluggish performance from our application, an on-demand streaming media CMS. About the same time our Cacti monitoring system sent a blizzard of emails. One of the more telling alerts was a graph of iostat await. Performance became so degraded that Pingdom began sending "server down" notifications. The overall load was moderate, there was not traffic spike. After logging onto the application servers, NFS clients of the NAS, I confirmed that just about everything was experiencing highly intermittent and insanely long IO wait times. And once I hopped onto the primary NAS node itself, the same delays were evident when trying to navigate the problem array's file system. Time to fail over, that went well. Within 20 minuts everything was confirmed to be back up and running perfectly. Post-Mortem: After any and all system failures I perform a post-mortem to determine the cause of the failure. First thing I did was ssh back into the box and start reviewing logs. It was offline, completely. Time for a trip to the data center. Hardware reset, backup an and running. In /var/syslog I found this scary looking entry: Nov 15 06:49:44 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_00], 6 Currently unreadable (pending) sectors Nov 15 06:49:44 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_07], SMART Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 171 to 170 Nov 15 06:49:45 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_10], 16 Currently unreadable (pending) sectors Nov 15 06:49:45 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_10], 4 Offline uncorrectable sectors Nov 15 06:49:45 umbilo smartd[2827]: Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error Nov 15 06:49:45 umbilo smartd[2827]: # 1 Short offline Completed: read failure 90% 6576 3421766910 Nov 15 06:49:45 umbilo smartd[2827]: # 2 Short offline Completed: read failure 90% 6087 3421766910 Nov 15 06:49:45 umbilo smartd[2827]: # 3 Short offline Completed: read failure 10% 5901 656821791 Nov 15 06:49:45 umbilo smartd[2827]: # 4 Short offline Completed: read failure 90% 5818 651637856 Nov 15 06:49:45 umbilo smartd[2827]: So I went to check the Cacti graphs for the disks in the array. Here we see that, yes, disk 7 is slipping away just like syslog says it is. But we also see that disk 8's SMART Read Erros are fluctuating. There are no messages about disk 8 in syslog. More interesting is that the fluctuating values for disk 8 directly correlate to the high IO wait times! My interpretation is that: Disk 8 is experiencing an odd hardware fault that results in intermittent long operation times. Somehow this fault condition on the disk is locking up the entire array Maybe there is a more accurate or correct description, but the net result has been that the one disk is impacting the performance of the whole array. The Question(s) How can a single disk in a hardware SATA RAID-10 array bring the entire array to a screeching halt? Am I being naïve to think that the RAID card should have dealt with this? How can I prevent a single misbehaving disk from impacting the entire array? Am I missing something?

    Read the article

< Previous Page | 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133  | Next Page >