  • Sessionstate not being saved between pages

    - by Grant
    Hi, i am having problems with an asp.net c# site whereby i am setting a session state object to true and then redirecting to another page that needs to check the value of the session state object and it is null. Sometimes it is set correctly and other times is is simply null. When i debug on my local machine it works perfectly every time. Only when i upload to my web server does this temperamental behaviour happen. As it is based around the security of the site it is obviously important that the session data be valid and accurate every time. Is session state data unreliable? AFAIK its set to inproc, cookieless, 30 min timeout, vanilla installation of IIS. Does anyone have any suggestions? Perhaps i need to thread.sleep inbetween the storing of the session data and the reading? NB: the time between the write and the read is about 70ms.. ample time for the data to be written to RAM.....

    Read the article

  • Trying to configure HWIC-3G-HSPA

    - by user1174838
    I'm trying to configure a couple of Cisco 1941 routes. The are both identical routers. Each as a HWIC-1T (Smart Serial interface) and a HWIC-3G-HSPA 3G interface. These routers are to be sent to remote sites. We have connectivity to one of the sites but if remote site A gors down we lose connectivity to remote site B. The HWIC-1T is the primary WAN interface using frame relay joining the two remote sites We want the HWIC-3G-HSPA to be usable for direct connectivity from head office to remote site B, and also the HWIC-3G-HSPA is do be used for comms between the remote sites when the frame relay is down (happens quite a bit). I initialy tried to do dynamic routing using EIGRP however in my lab setup of laptop - 1941 - 1941 - laptop, I was unable to get end to end connectivity. I later settled on static routing and have got end to end connectivity but only over frame relay, not the HWIC-3G-HSPA. The sanitized running config for remote site A: version 15.1 service tcp-keepalives-in service tcp-keepalives-out service timestamps debug datetime msec service timestamps log datetime msec service password-encryption service udp-small-servers service tcp-small-servers ! hostname remoteA ! boot-start-marker boot-end-marker ! ! logging buffered 51200 warnings enable secret 5 censored ! no aaa new-model clock timezone wst 8 0 ! no ipv6 cef ip source-route ip cef ! ip domain name yourdomain.com multilink bundle-name authenticated ! chat-script gsm "" "ATDT*98*1#" TIMEOUT 30 "CONNECT" ! username admin privilege 15 secret 5 censored ! controller Cellular 0/1 ! interface Embedded-Service-Engine0/0 no ip address shutdown ! interface GigabitEthernet0/0 ip address 192.168.2.5 255.255.255.0 duplex auto speed auto ! interface GigabitEthernet0/1 no ip address shutdown duplex auto speed auto ! interface Serial0/0/0 ip address 10.1.1.2 255.255.255.252 encapsulation frame-relay cdp enable frame-relay interface-dlci 16 frame-relay lmi-type ansi ! interface Cellular0/1/0 ip address negotiated encapsulation ppp dialer in-band dialer idle-timeout 2147483 dialer string gsm dialer-group 1 async mode interactive ppp chap hostname censored ppp chap password 7 censored cdp enable ! interface Cellular0/1/1 no ip address encapsulation ppp ! interface Dialer0 no ip address ! ip forward-protocol nd ! no ip http server no ip http secure-server ! ip route 0.0.0.0 0.0.0.0 Serial0/0/0 210 permanent ip route 0.0.0.0 0.0.0.0 Cellular0/1/0 220 permanent ip route 172.31.2.0 255.255.255.0 Cellular0/1/0 permanent ip route 192.168.3.0 255.255.255.0 10.1.1.1 permanent ip route 192.168.3.0 255.255.255.0 Cellular0/1/0 210 permanent ! access-list 1 permit any dialer-list 1 protocol ip list 1 ! control-plane ! line con 0 logging synchronous login local line aux 0 line 2 no activation-character no exec transport preferred none transport input all transport output pad telnet rlogin lapb-ta mop udptn v120 ssh stopbits 1 line 0/1/0 exec-timeout 0 0 script dialer gsm login modem InOut no exec transport input all rxspeed 7200000 txspeed 5760000 line 0/1/1 no exec rxspeed 7200000 txspeed 5760000 line vty 0 4 access-class 23 in privilege level 15 password 7 censored login local transport input all line vty 5 15 access-class 23 in privilege level 15 password 7 censored login local transport input all line vty 16 1370 password 7 censored login transport input all ! scheduler allocate 20000 1000 end The sanitized running config for remote site B: version 15.1 service tcp-keepalives-in service tcp-keepalives-out service timestamps debug datetime msec service timestamps log datetime msec service password-encryption service udp-small-servers service tcp-small-servers ! hostname remoteB ! boot-start-marker boot-end-marker ! logging buffered 51200 warnings enable secret 5 censored ! no aaa new-model clock timezone wst 8 0 ! no ipv6 cef ip source-route ip cef ! no ip domain lookup ip domain name yourdomain.com multilink bundle-name authenticated ! chat-script gsm "" "ATDT*98*1#" TIMEOUT 30 "CONNECT" username admin privilege 15 secret 5 censored ! controller Cellular 0/1 ! interface Embedded-Service-Engine0/0 no ip address shutdown ! interface GigabitEthernet0/0 ip address 192.168.3.1 255.255.255.0 duplex auto speed auto ! interface GigabitEthernet0/1 no ip address shutdown duplex auto speed auto ! interface Serial0/0/0 ip address 10.1.1.1 255.255.255.252 encapsulation frame-relay clock rate 2000000 cdp enable frame-relay interface-dlci 16 frame-relay lmi-type ansi frame-relay intf-type dce ! interface Cellular0/1/0 ip address negotiated encapsulation ppp dialer in-band dialer idle-timeout 2147483 dialer string gsm dialer-group 1 async mode interactive ppp chap hostname censored ppp chap password 7 censored ppp ipcp dns request cdp enable ! interface Cellular0/1/1 no ip address encapsulation ppp ! interface Dialer0 no ip address ! ip forward-protocol nd ! no ip http server no ip http secure-server ! ip route 0.0.0.0 0.0.0.0 Serial0/0/0 210 permanent ip route 0.0.0.0 0.0.0.0 Cellular0/1/0 220 permanent ip route 172.31.2.0 255.255.255.0 Cellular0/1/0 permanent ip route 192.168.2.0 255.255.255.0 10.1.1.2 permanent ip route 192.168.2.0 255.255.255.0 Cellular0/1/0 210 permanent ! kron occurrence PING in 1 recurring policy-list ICMP ! access-list 1 permit any dialer-list 1 protocol ip list 1 ! control-plane ! line con 0 logging synchronous login local line aux 0 line 2 no activation-character no exec transport preferred none transport input all transport output pad telnet rlogin lapb-ta mop udptn v120 ssh stopbits 1 line 0/1/0 exec-timeout 0 0 script dialer gsm login modem InOut no exec transport input all rxspeed 7200000 txspeed 5760000 line 0/1/1 no exec rxspeed 7200000 txspeed 5760000 line vty 0 4 access-class 23 in privilege level 15 password 7 censored login transport input all line vty 5 15 access-class 23 in privilege level 15 password 7 censored login transport input all line vty 16 1370 password 7 censored login transport input all ! scheduler allocate 20000 1000 end The last problem I'm having is the 3G interfaces go down after only a few minutes of inactivity. I've tried using kron to ping the local HWIC-3G-HSPA interface (cellular 0/1/0) every minute but that hasn't been successful. Manually pinging the IP assigned (by the telco) to ce0/1/0 does bring the interface up. Any ideas? Thanks

    Read the article

  • Embedding mercurial revision information in Visual Studio c# projects automatically

    - by Mark Booth
    Original Problem In building our projects, I want the mercurial id of each repository to be embedded within the product(s) of that repository (the library, application or test application). I find it makes it so much easier to debug an application ebing run by custiomers 8 timezones away if you know precisely what went into building the particular version of the application they are using. As such, every project (application or library) in our systems implement a way of getting at the associated revision information. I also find it very useful to be able to see if an application has been compiled with clean (un-modified) changesets from the repository. 'Hg id' usefully appends a + to the changeset id when there are uncommitted changes in a repository, so this allows is to easily see if people are running a clean or a modified version of the code. My current solution is detailed below, and fulfills the basic requirements, but there are a number of problems with it. Current Solution At the moment, to each and every Visual Studio solution, I add the following "Pre-build event command line" commands: cd $(ProjectDir) HgID I also add an HgID.bat file to the Project directory: @echo off type HgId.pre > HgId.cs For /F "delims=" %%a in ('hg id') Do <nul >>HgID.cs set /p = @"%%a" echo ; >> HgId.cs echo } >> HgId.cs echo } >> HgId.cs along with an HgId.pre file, which is defined as: namespace My.Namespace { /// <summary> Auto generated Mercurial ID class. </summary> internal class HgID { /// <summary> Mercurial version ID [+ is modified] [Named branch]</summary> public const string Version = When I build my application, the pre-build event is triggered on all libraries, creating a new HgId.cs file (which is not kept under revision control) and causing the library to be re-compiled with with the new 'hg id' string in 'Version'. Problems with the current solution The main problem is that since the HgId.cs is re-created at each pre-build, every time we need to compile anything, all projects in the current solution are re-compiled. Since we want to be able to easily debug into our libraries, we usually keep many libraries referenced in our main application solution. This can result in build times which are significantly longer than I would like. Ideally I would like the libraries to compile only if the contents of the HgId.cs file has actually changed, as opposed to having been re-created with exactly the same contents. The second problem with this method is it's dependence on specific behaviour of the windows shell. I've already had to modify the batch file several times, since the original worked under XP but not Vista, the next version worked under Vista but not XP and finally I managed to make it work with both. Whether it will work with Windows 7 however is anyones guess and as time goes on, I see it more likely that contractors will expect to be able to build our apps on their Windows 7 boxen. Finally, I have an aesthetic problem with this solution, batch files and bodged together template files feel like the wrong way to do this. My actual questions How would you solve/how are you solving the problem I'm trying to solve? What better options are out there than what I'm currently doing? Rejected Solutions to these problems Before I implemented the current solution, I looked at Mercurials Keyword extension, since it seemed like the obvious solution. However the more I looked at it and read peoples opinions, the more that I came to the conclusion that it wasn't the right thing to do. I also remember the problems that keyword substitution has caused me in projects at previous companies (just the thought of ever having to use Source Safe again fills me with a feeling of dread *8'). Also, I don't particularly want to have to enable Mercurial extensions to get the build to complete. I want the solution to be self contained, so that it isn't easy for the application to be accidentally compiled without the embedded version information just because an extension isn't enabled or the right helper software hasn't been installed. I also thought of writing this in a better scripting language, one where I would only write HgId.cs file if the content had actually changed, but all of the options I could think of would require my co-workers, contractors and possibly customers to have to install software they might not otherwise want (for example cygwin). Any other options people can think of would be appreciated. Update Partial solution Having played around with it for a while, I've managed to get the HgId.bat file to only overwrite the HgId.cs file if it changes: @echo off type HgId.pre > HgId.cst For /F "delims=" %%a in ('hg id') Do <nul >>HgId.cst set /p = @"%%a" echo ; >> HgId.cst echo } >> HgId.cst echo } >> HgId.cst fc HgId.cs HgId.cst >NUL if %errorlevel%==0 goto :ok copy HgId.cst HgId.cs :ok del HgId.cst Problems with this solution Even though HgId.cs is no longer being re-created every time, Visual Studio still insists on compiling everything every time. I've tried looking for solutions and tried checking "Only build startup projects and dependencies on Run" in Tools|Options|Projects and Solutions|Build and Run but it makes no difference. The second problem also remains, and now I have no way to test if it will work with Vista, since that contractor is no longer with us. If anyone can test this batch file on a Windows 7 and/or Vista box, I would appreciate hearing how it went. Finally, my aesthetic problem with this solution, is even strnger than it was before, since the batch file is more complex and this there is now more to go wrong. If you can think of any better solution, I would love to hear about them.

    Read the article

  • Debugging IDAPython Scripts outside of IDAPro

    - by YaronK
    I'm kinda new to scripting for IDA - nevertheless, I've written a complex script I need to debug, as it is not working properly. It is composed of a few different files containing a few different classes. Writing line-by-line in the commandline is not effective for obvious reasons. Running a whole script from the File doesn't allow debugging. Is there a way of using the idc, idautils, idaapi not from within IDA? I've written the script on PyDev for Eclipse, I'm hoping for a way to run the scripts from within it. A similar question is, can the api classes I have mentioned work on idb files without IDA having them loaded? Thanks.

    Read the article

  • Strange fstream problem

    - by noname
    Hi, I have really strange problem. In Visual C++ express, I have very simple code, just: #include <fstream> using namespace std; int main() { fstream file; file.open("test.txt"); file<<"Hello"; file.close(); } This same code works OK in my one project, but when I create now project and use this same lines of code, no file test.txt is created. Please, what is wrong?¨ EDIT: I expect to see test.txt in VS2008/project_name/debug - just like the first functional project does.

    Read the article

  • Preprocessor macros: how to insert arguments?

    - by mhambra
    Hi all, the code has a number of following sections: int filter; #ifdef INPUTFILTER_FOO LOG4CXX_DEBUG(log, "FOO filter used"); filter = F_FOO; #endif They are used multiple times in the code (used to provide I/O, threading support etc for all testing configurations), Circa they are essential for debugging but make the code look harsh, want to replace them with macros, one for each category_type namespace. So, want to expand the following: MACROSTUFFBAZ(log2, stuff, "BAZ") <- the text part is unique for each class, so it needs to be included in macro too. to: #ifdef INPUTSTUFF_BAZ LOG4CXX_DEBUG(log2, "BAZ stuff used"); stuff = S_BAZ; #endif To define macros, plan to use this: debug.hpp: #ifdef INPUTSTUFF_BAZ #define MACROSTUFFBAZ ... #else #define MACROSTUFFBAZ .. no code! #endif #endif (at least this will give a clear overview of the things currently undergoing probation, without seeing them around the code)

    Read the article

  • How am I supposed to deploy an ASP.NET MVC 4.0 website?

    - by Matt Frear
    What's the recommended way to deploy a website created with ASP.NET 4.0 and Visual Studio 2010? I've previously always added a web setup project to my solution, and used that to create an MSI, even for small applications. But when I build a web setup project in VS2010 it kind of works but some stuff still seems broken: 1. I need to turn on IIS 6 Compatibility on a Win 2008 R2 box to get the msi to run. 2. The msi includes web.config, web.debug.config, and web.release.config. I thought VS's web.config transformations was supposed to take care of that. -Matt

    Read the article

  • PhysX SDK - error LNK2019: unresolved external symbol when compiling "wavefront.cpp"

    - by user370102
    Hi all, I'm using the PhysX SDK and I'm trying to load an .obj file with the WavefrontObj object which is defined by the files "wavefront.h/.cpp", localized in the samples directory. When I'm compiling my project, I got this error: 1Linking... 1wavefront.obj : error LNK2019: unresolved external symbol "char * __cdecl FindMediaFile(char const *,char *)" (?FindMediaFile@@YAPADPBDPAD@Z) referenced in function "public: void __thiscall WAVEFRONT::InPlaceParser::SetFile(char const *)" (?SetFile@InPlaceParser@WAVEFRONT@@QAEXPBD@Z) 1C:\Users\Nicolas\Documents\GI05\CSED451 - Computer Graphics\ToyFK_Project\Debug\ToyFK_Project.exe : fatal error LNK1120: 1 unresolved externals I guess I forgot to link a library or something but I really can't find what... It's driving me crazy!!! Does somebody have an idea? Thank you

    Read the article

  • Debugging ASP.NET on a built-in web server suddenly stops

    - by Anton Gogolev
    I have Windows Server 2008 (64-bit), VS 2008 with its built-in webserver and an ASP.NET MVC 1.0 webapp. All I'm trying to do is to debug said app. I have a bunch of breakpoints, but they behave in a very strange way. When I fist start a debugging session with F5 and hit a breakpoint, the debugger stops just fine. However, after serveral F10s/F11s debugging suddenly "stops" (no exceptions at that time), but neither VS detaches from browsers' process, nor webapp execution stops: Visual Studio stays attached, and web request continues executing as usual. I tried various browsers (Chrome, Firefox, IE), but to no avail. What do I do to solve this? It really drives me insane.

    Read the article

  • Tripple-wrapping fails: \colorbox ? \NewEnviron ? \newenvironment fails

    - by o_O Tync
    Hello! I am trying to wrap an environment created with \NewEnviron (package 'environ') into an old good \newenvironment: \NewEnviron{test}{\colorbox[gray]{0.7}{\BODY}} \newenvironment{wrapper}{\begin{test}}{\end{test}} \begin{wrapper} debug me \end{wrapper} However, this gives me a strange error: LaTeX Error: \begin{test} on input line 15 ended by \end{wrapper}. LaTeX Error: \begin{wrapper} on input line 15 ended by \end{document}. If I replace \NewEnviron{test}{aaa(\BODY)bbb} with \newenvironment{test}{aaa(}{)bbb} — everything works as expected! It seems like \NewEnviron fails to find its end for some reason. I'm trying to do some magic with 'floatfig' wrapped into a \colorbox so I need a way to convert \colorbox to an environment and wrap it into another one. I can define a new command but it's not a very good idea. Thanks in advance!

    Read the article

  • Reference non-GAC version of DLL in Visual Studio 2010

    - by Eric J.
    This is similar to Add Non-GAC reference to project but the solutions presented there don't seem to help. I have a WinForms UI Library (Krypton from ComponentFactory) installed in the GAC. There's a bug I want to track down in that library, so I added the source code to my solution, removed the old references from my WinForms project to Krypton DLLs, added them back as a project references, ensured Copy Local is set to true, double-checked that the path (on reference properties tab) points to my local project, and... ...the GAC version is still being used while debugging. I cannot set a breakpoint in the Krypton source, Debugger.Break() or other code changes to not execute, and when I start the Visual Studio 2010 debugger, I see a Loading from ... GAC_MISL message relating to the Krypton DLLs flash by in the VS 2010 status bar. The DLLs are not copied to the WinForm's Debug folder. How can I reference the "project" version of the files while debugging while leaving them registered in the GAC?

    Read the article

  • implement button click in html

    - by vbNewbie
    I have been trying to execute a button event in html page that displays additional content on the web page. I am getting a null reference error when using the getelementbyid and not sure how to change this. Here is the html reference I need to engage: <div class="button" style="float:none;width:180px;margin:20px auto 30px;"><a href="#" id="more" style="width:178px">Show more ?</a></div> </div> and here is my code: Dim wb As New WebBrowser wb.Navigate(fromUrl) While wb.ReadyState <> WebBrowserReadyState.Complete Application.DoEvents() End While Debug.Write(wb.DocumentText) Dim htmlElements As HtmlElementCollection = wb.Document.GetElementsByTagName("<a") If Not wb.Document Is Nothing Then Try If wb.DocumentText.Contains("more") Then If wb.Document.GetElementById("more").GetAttribute("href") Then wb.Document.GetElementById("more").InvokeMember("#") End If End If Catch ex As Exception MessageBox.Show(ex.Message.ToString) End Try End If I appreciate any ideas.

    Read the article

  • Initiate a PHP class where class name is a variable

    - by ed209
    I need some help with an error I have not encountered before and can't seem to find anywhere. In a PHP mvc framework (just from a tutorial) I have the following: // Initiate the class $className = 'Controller_' . ucfirst($controller); if (class_exists($className)) { $controller = new $className($this->registry); } $className is showing the correct class name (case is also correct). But when I run it I get this in the apache error log (no php error) [Wed Mar 31 10:34:12 2010] [notice] child pid 987 exit signal Segmentation fault (11) Process id is different on every call. I am running PHP 5.3.0 on os x 10.6. This site seems to work on 5.2.11 on another Mac. Not really sure where to go next to debug it. I guess it could be an apache setting as much as a php bug or a problem with the code... any suggestions on where to look next?

    Read the article

  • Progress bar increment by 1 every 100th of second

    - by Matthew De'Loughry
    I'm trying to get a JProgressBar to increment by 1 every 100th of a second, and at the moment I'm using Thread.sleep(100) inside a while statement like so: try { while (i<=100){ doTime(); } } catch (InterruptedException ex) { Logger.getLogger(SplashScreen.class.getName()).log(Level.SEVERE, null, ex); } public void doTime() throws InterruptedException{ jLabel1.setText("sleeping"); Thread.sleep(100); jLabel1.setText("start"); i++; pb.setValue(i); pb.repaint(); } and If I debug by doing a System.out.println it displays in real time but the swing GUI freezes until it drops out of the while loop can anyone help? thanks matt

    Read the article

  • Visual Studio debugger problem

    - by Alexandre Pepin
    In Visual Studio 2008, after debugging about 1-2 minutes, when I press F10 (Step Over), the debugger hangs and Visual Studio freezes for 5-10 seconds and then go to the next line. Then whatever I do (F10, F5, F11, etc), the debugger continues the execution as if i pressed F5 and all my forms that I was debugging close. I always have to restart the application. It is very hard to reproduce and it does not occurs every time I want to debug something. Does anyone has a solution ?

    Read the article

  • Debugging JavaScript in Internet Explorer

    - by Erik W
    I am working on a relatively complex JavaScript-driven website. It runs great in all browsers except Internet Explorer. I am getting this very curious error: "A Runtime Error has occurred. Do you wish to Debug? Line: 93,865,600. Error: Expected ';'" The issue is, I don't have 93 million lines of code, and clicking "Yes" doesn't attach to Visual Studio like it normally does. I can click on 'No' and the website continues to run fine, but if a user doesn't have JavaScript debugging disabled, I don't want them to see this meaningless error. Suggestions/Tools/Plugins to get to the bottom of this? And yeah, I learned my lesson, switch over and check my project in Internet Explorer more often... Thanks,

    Read the article

  • How to define using statements in web.config?

    - by Hasan Gürsoy
    I'm using MySql in my asp.net project. But I don't want to type every "using MySql.Data.MySqlClient;" statement in every aspx.cs file. How can I define this lines in web.config file? I've defined some namespaces like below but this only works for aspx pages: <?xml version="1.0"?> <configuration> <system.web> <compilation debug="false" targetFramework="4.0"/> <pages> <namespaces> <add namespace="System.Web.Configuration"/> <add namespace="MySql.Data"/> <add namespace="MySql.Data.MySqlClient"/> </namespaces> </pages> </system.web> </configuration>

    Read the article

  • C#: proprietary DLLs requiring access to my assemblies

    - by Craig Johnston
    My solution uses a proprietary assembly, which when debugging the solution throws an Exception saying it can't find an assembly that is meant to be one of the projects in my solution. I cannot add a reference to the proprietary assembly because all I have is the DLL. When I compile everything into a single application directory and run the app it works fine, but I want to debug. Where should assemblies be placed if you want a proprietary assembly in the solution to see them? I assume the issue is that there is no path specified and it is just looking in a default directory of some kind.

    Read the article

  • Customer session is different in different parts of a Magento website

    - by Josh Pennington
    I have a function inside of a Helper in Magento that returns whether or not a customer attribute equals one. Here is my Helper class class Nie_Nie_Helper_Data extends Mage_Core_Helper_Abstract { public function isNieAdmin() { if(Mage::getSingleton('customer/session')->getCustomer()->getNieAdmin() == 1) { return true; } else { return false; } } } Now when I call this function from a class that extends Mage_Core_Block_Template, everything seems to work fine. However when I try to use this inside one of my controllers, it does not work. In fact when I do Mage::getSingleton('customer/session')-getCustomer()-debug() the only variable that is returned is the website_id. Does anyone know what I have to do in order to get this to work? Thanks Josh Pennington

    Read the article

  • Problem using pantheios file stock back end

    - by Tanuj
    I am trying to use pantheios file stock back end to log from my dll in c++. The file gets created but nothing gets written to the file. Here is a snippet of my code if (pantheios::pantheios_init() < 0) { MessageBox(NULL, "Init Failed", "fvm", MB_OK); }else { MessageBox(NULL, "Init Passed", "fvm", MB_OK); pantheios::log_INFORMATIONAL("Logger enabled!"); } DWORD pid = GetCurrentProcessId(); sprintf_s(moduleName, sizeof(moduleName), "C:\\%d.log", pid); pantheios_be_file_setFilePath(moduleName, PANTHEIOS_BE_FILE_F_TRUNCATE,PANTHEIOS_BE_FILE_F_TRUNCATE, PANTHEIOS_BEID_LOCAL); pantheios::log(pantheios::debug, "Entering main"); I get the Init Passed message box but no log statements are dumped in the file.

    Read the article

  • How to load program reading stdin and taking parameters in gdb?

    - by vinc456
    I have a program that takes input from stdin and also takes some parameters from command line. It looks like this: cat input.txt myprogram -path "/home/user/work" I try to debug the code with gdb inside emacs, by M-x gdb, I try to load the program with the command: gdb cat input.txt myprogram -path "/home/user/work" However, gdb does not like it. Question cribbed from here. Unfortunately I don't understand the solution and am not sure what to do beyond compiling with the -g option and running the command M-x gdb.

    Read the article

  • Problem in Closing Exe

    - by chandruswami
    In C#, I am using form1 as homescreen,.. while running exe from Debug folder, form1.exe appears in Process tab in task manager,... The problem is: Through form1 at runtime, i may create more instances of form1 while trying to close particular instance, the instances closed,.. but still exe appears in task manager. what i found: If i close the instances in the order what we created,.. all exe closes correctly,.. but if close the 4th instance and then 3rd instance,.. exe remains in task manager. (instead of 3rd and then 4th instance) I also used Application.Exit() but still the Exe remains in taskmanager,......

    Read the article

  • T-SQL: How Do I Create A "Private" Function Inside A Stored Procedure

    - by RPM1984
    Okay so im writing a SQL Server 2008 Stored Procedure (maintenance script). In doing so, being a good boy i've done plenty of error handling, checking rowcounts, printing output messages, etc But in doing this, ive found myself writing over and over again something like this: SELECT @RowsAffected = @@ROWCOUNT IF @RowsAffected > 0 BEGIN PRINT CAST(@RowsAffected, NVARCHAR(2)) + 'rows updated.' END Or debug messages like this: PRINT 'User ' + CAST(@UserId AS NVARCHAR(5)) + ' modified successfully' Is there a way i can create a kind of 'subroutine' inside the stored procedure (like a private method) that can accept something as a parameter (doesnt have to though) and do some logic? I want to be able to do something like this: CheckRowCounts Or this: PrintUserUpatedMessage(@UserId) Which would then perform the above logic (check rowcount, print message, etc) And yes obviously i can create a UDF, but then i would need to create/drop it etc as this logic is only required for the life of the execution of this stored procedure. Getting sick and tired of writing the same code over and over again, and changing all the different areas ive used it when i get an error =) Can anyone help?

    Read the article

  • "Attach to process" missing from Delphi 7's Run menu

    - by glob
    I have to resurrect an ancient Delphi 7 application, which means I have to use the D7 IDE. Upgrading the project to a more recent version of Delphi unfortunately isn't an option. My new D7 installation's Run menu is missing Attach to Process. Aside from the missing menu item, the debugger works fine (I can debug normal Delphi executables started with Run). I know D7 supported this feature (it's in the help file), so does anyone have any idea what I've missed? The installation is Delphi 7 Enterprise (Version 7.0 Build 4.453). Current Run menuitems: Run Parameters... - Step Over Trace Into Trace to next Source line Run to Cursor Run Until Return Show Execution Point Program Pause Program Reset - Evaluate/Modify Add Watch Add Breakpoint

    Read the article

  • iPhone: Cannot get simulator to generate .gcda profiling data files.

    - by Derek Clarkson
    I'm attempting to profile my code using the iPhone simulator. I've enabled Generate Test Coverage File and Instrument Program Flow and added -lgcov to the linker flags. According to everything I've read that should be all I need to do in terms of setup. Executing the program I can see the .gcno files appearing along side the .o compiled code in the build/.build/Debug-iphonesimulator/.build/Objects-normal/i386 directory. But when I run the app in the simulator I do not get any *.gcda files appearing. My understanding is that these files contain the data from the instrumentation. But I cannot find them anywhere on the computer. I know they can be produced and appear along side the *.gcno files because I have an old trashed buil directory which does have them. I just cannot figure out what I have to do to get them to appear and record the run. Any help appreciated.