  • How can I restore my original IME Romaji input settings?

    - by JOhn K
    the this one, Japanese IME on Windows: switch back to romaji input method (3) did not help. The problem seems the same. My Vista home premium version PC, I had been using Microsoft IME to use English and Japanese input using romaji henkan for a long time. One day, all of a sudden, first when I started up the PC, it has cap lock indicator ON. So, I press SHIFT key, CAP lock indicator is off!(This I have to do every morning.) Now when I want to type romaji input to change to Japanese, I switch EN English (United States) to "JP Japanese (Japan) and select input to hiragana input. It worked until that day. But now when I set to input romaji for hiragana as I used to do and start typing, then it shows Japanese hiragana directly on the display just as keyboard setting as Japanese ???109???????? as shown in Wikipedia JIS keyboard. And I cannot show hiragana as I wanted ( I can convert to Kanji OK) etc. by hitting space key. But its key board arrangement is what I never learned. Other thing I found is when I hit "`" key, it switches between hiragana and alphabet. When I see Control panel setting it is the same setting as I have seen. Please suggest me a solution to get the original setting for IME input mode as I used to do. John K.

    Read the article

  • can't figure out why apache LDAP auth fails

    - by SethG
    Suddenly, yesterday, one of my apache servers became unable to connect to my LDAP (AD) server. I have two sites running on that server, both of which use LDAP to auth against my AD server when a user logs in to either site. It had been working fine two days ago. For reasons unknown, as of yesterday, it stopped working. The error log only says this: auth_ldap authenticate: user foo authentication failed; URI /FrontPage [LDAP: ldap_simple_bind_s() failed][Can't contact LDAP server], referer: http://mysite.com/ I thought perhaps my self-signed SSL cert had expired, so I created a new one for mysite.com, but not for the server hostname itself, and the problem persisted. I enabled debug-level logging. It shows the full SSL transaction with the LDAP server, and it appears to complete without errors until the very end when I get the "Can't contact LDAP server" message. I can run ldapsearch from the commandline on this server, and I can login to it, which also uses LDAP, so I know that the server can connect to and query the LDAP/AD server. It is only apache that cannot connect. Googling for an answer has turned up nothing, so I'm asking here. Can anybody provide insight to this problem? Here's the LDAP section from the apache config: <Directory "/web/wiki/"> Order allow,deny Allow from all AuthType Basic AuthName "Login" AuthBasicProvider ldap AuthzLDAPAuthoritative off #AuthBasicAuthoritative off AuthLDAPUrl ldaps://domain.server.ip/dc=full,dc=context,dc=server,dc=name?sAMAccountName?sub AuthLDAPBindDN cn=ldapbinduser,cn=Users,dc=full,dc=context,dc=server,dc=name AuthLDAPBindPassword password require valid-user </Directory>

    Read the article

  • Windows 8 & Hyper-V Can't Bridge Wifi Connection

    - by xinunix
    So I have an odd issue that I can't quite figure out... I am running Windows 8 Enterprise on a Dell 6420 laptop. I have a Broadcom 802.11n wireless adapter. I am connected to an home router (Netgear WNDR3700) that is connected to the internet. It is a very simple home network setup. I am trying to stand-up a few VMs in Hyper-V and want the VMs to be able to access the internet over my wireless connection. I have found numerous examples of how to set this up using both External and Internal Virtual Switches but have yet to be able to get it to work on my machine. I have narrowed the issue down to the fact that my host machine always loses internet connection when I bridge my wifi connection (both when it is bridged automatically by windows when I setup an external virtual switch bound to the wifi adapter or if I do it manually by creating an internal virtual switch, right click on it and my wifi network and select "Bridge Connections".) In both cases after the bridge is established, my host machine can no longer connect to the internet. I am not sure where to start with troubleshooting this problem. After the bridge is setup, an ipconfig shows all netowrk devices on the machine as "Media Disconnected". I do know that the wireless adapter is connected to the router b/c it shows the connection as active and full-strength. The only thing I can possibly think of is that this machine also has the Cisco VPN client installed on it which installs a Cisco Virtual Network Adapter. Is it possible that this Cisco Virtual Adapter is causing me issues when I try to bridge? I saw some people had a similar issue with a VirtualBox virtual adapter when trying to share via Hyper-V. Any thoughts or suggestions on how to troubleshoot?

    Read the article

  • OS X random, jumpy dragging behavior

    - by Chris
    This problem has been going on since I got 10.7, and is persisting or even getting worse since I updated to Mavricks. The best way to describe it is thru an example- Let's say I'm working in Safari. Everything is working fine. Then, I'll switch to another app by clicking on it's window, for example, I'll click on Messages to shoot back a reply. When I click back to Safari, keyboard and mouse inputs don't work! The only way I can regain control of the app (Safari) is by clicking on the apps top bar, which then causes the app to jump left or right. If I'm in Messages and I switch back to Safari by clicking said top bar, it works fine. Same with switching back and forth using command-tab. I've narrowed the problem down to this - the first app (Safari, in this example) is, for some reason, deciding that I'm in the process of dragging the window around. This could be just an oddly persistent glitch in my system, but has anyone else seen this before? Perhaps a misplaced default write... somewhere along the line? Update A PRAM reset did absolutely nothing

    Read the article

  • Configure Cisco Pix 515 with DMZ and no NAT

    - by Rickard
    I hope that someone could shed some light over my situation, as I am fairly new to PIX configurations. I will be getting a new net for my department, which I am going to configure. At my hands, I have a Cisco PIX 515 (not E), a Cisco 2948 switch (and if needed, I can bring up a 2621XM router, but this is my private and not owned by my dept.). The network I will be getting is the following: 10.12.33.0/26 Link net between the ISP routers and my network will be 10.12.32.0/29 where GW is .1 and HSRP roututers are .2 and .3 The ISP has asked me not to NAT the addresses on my side, as they will set it up to give 10.12.33.2 as a one-to-one nat to a public IP. The rest of the IP's will be a many-to-one NAT to another public IP. 10.12.33.2 is supposed to be my server placed on the DMZ, the rest of the IP's will be used for my clients and the AD server (which is currently also acting as a DHCP server in the old network config with another ISP). Now, the question is, how would I best configure this? I mean, am I thinking wrong here, I am expected to put the PIX first from the ISP outlet, then to the switch which will connect my clients. But with the ISP routers being on a different network, how will the firewall forward the packets to the other network, it's a firewall, not a router. I have actually never configured a pix before, and fortunately, this is more like a lab network, not a production network, so if something goes wrong it's not the end of the world, if though annoying. I am not asking for a full configuration from anyone, just some directions, or possibly some links which will give me some hints. Thank you very much!

    Read the article

  • How can I split 200Mbps of streaming traffic into routers?

    - by Jared
    As the title says, I have 200Mbps of streaming video traffic coming into my command center. How do I split the load between routers? Setup is like this: fiber --- router --- switch --- workstations I'm sorry I haven't dealt with this much traffic before. so please be gentle if you're going to kick me out :) EDITED FOR DETAILS: Okay, this specific project is for our company's IP CCTV system. We have deployed over 100++ cameras all over a building/campus and we have estimated each camera to take about 2Mbps of bandwidth each. Now, they're all connected to a switch and that's entirely fine. But coming into our command center, they have to be on a router since it'll get more than 200++ cameras next year (and I don't want to have too many hosts on one subnet). My plan was to have the 1st hundred on a 172.16.9.x block and the 2nd hundred on a 172.16.10.x block (all /24). The servers I have are currently sized to match (about 5 dual 6-core xeons) and I'd have about 19 workstations all streaming video from the 5 servers. (servers pull video from the cameras). But 200Mbps of constant traffic? How the hell do I even break this up? I need to have 1 gateway, to manage the routes... I honestly think I'm way in over my head.

    Read the article

  • Switching from prefork MPM to worker MPM + php-fpm on ubuntu

    - by Shane
    All tutorials I found were how to fresh install worker MPM + PHP-FPM, since my wordpress blog's already up and running with prefork MPM, correct me if I'm wrong in the simulated installation process: I'm on ubuntu and according to some tutorials, the following lines would do all the tricks: apt-get install apache2-mpm-worker libapache2-mod-fastcgi php5-fpm php5-gd a2enmod actions fastcgi alias Then you setup configuration in /etc/apache2/conf.d/php5-fpm.conf: <IfModule mod_fastcgi.c> AddHandler php5-fcgi .php Action php5-fcgi /php5-fcgi Alias /php5-fcgi /usr/lib/cgi-bin/php5-fcgi FastCgiExternalServer /usr/lib/cgi-bin/php5-fcgi -host 127.0.0.1:9000 -pass-header Authorization </IfModule> After all these, restart: service apache2 restart && service php5-fpm restart Question: 1) Would it cause any down time in the whole process for previously running sites with prefork MPM? 2) Do you have to change any already existent configuration files like php or mysql or apache2(would they take effect immediately after the switch without you doing anything)? 3) I've already have apc up and running, do you have to re-install/re-configure it after the switch? 4) How do you find out if apache2 is working in worker MPM mode as expected? Thanks a lot!

    Read the article

  • Can I have 2Gbit over 1Gbit Nics

    - by Daniel
    So this really baffles me. Apparently because 1Gbit can transmit data in both directions simultaneously it should be possible to get 2Gbit of data transfer on a single NIC (1Gbit flow seend and 1Gbit receive). People claim that because 1Gbit is full-duplex (almost always) it is exactly 2Gbit in total. My intuition and electrical background tells me that something is not right here 4 twisted pairs 250Mbit capacity each gives 1Gbit. Unless it is really possible to transfer data in both directions simultaneously. I did a test with iperf. Ubuntu server 12.04 <-- MacBook Pro. Both with decent CPU speed. Tested speed of connection individually and on Mac I can see 112MB/s regardless which direction data is going. On Ubuntu with vnstat and ifstat I got 970Mbit speeds. Now, launching iperf in server mode on both machines at the same time and sending data using 2 iperf clients shows that I'm for example on Ubuntu box sending at 600Mbit, and receiving 350Mbit. which adds up to pretty much 1Gbit link. So to me there is no magical 2Gbit. Can someone confirm that or tell why I'm wrong? Another thing that confuses me i the fact that e.g. 24-port switch has for example: Throughput»up»to:»50.6Mpps Switching»capacity:»68Gbps Switch»fabric»speed:»88Gbps Which would suggest thay can handle 2GBit per port.

    Read the article

  • Failover strategy for a 4 servers scenario

    - by Joao Villa-Lobos
    Hi all, I am trying to figure out how to set up replication & failover in a scenario with 4 servers (2 per location) where any server may assume the Master role. My initial scenario is the following one: 2 servers in location A (One Master, One Slave); 2 servers in location B (Two Slaves). For this I'm thinking on using the configuration Master-Master Active-Passive suggested on O'Reilly's "High Performance MySQL" on all of them so each one can become a Master when needed. If the Master "dies" the other server from location A assumes the Master role whenever possible. It will always have a bigger priority then the servers on location B. A server on location B will only switch to Master if no server on location A is able to do so. Since MySQL can't handle this automatically I need some other way to implement this. I've read already about heartbeat and Maatkit. Is this the way to go? Has anyone used this in a similar scenario? Is there some other way to go in order to achieve this? Any pointers about failout will be appreciated. I want to keep this as simple as possible avoiding stuff such as DRDB. I'm not concerned about high availability just a way to switch roles automatically without too many hassle. I'm using SuSe Enterprise 10 and MySQL 5.1.30-community. Thanks in advance, João

    Read the article

  • Selective Pointer device remapping in linux

    - by user6368
    I just got an HP 2710p (hp tablet, with digitizer), and I've played around with linux for a while now, and thought I would go ahead and install it. Everything works fine, excepting normal tablet functions, which is to be expected. I'm working on the screen rotation, and there are on-screen keyboards, etc, but I'm having issues with the stylus. I can tap and left click with the stylus as normal, but the side button (which in windows functions as a right mouse button) appears as a 'button 2' to xev (a middle/scroll wheel button). I can switch 'button 2' and 'button 3' universally using xmodmap, but I'd like to do so exclusively for stylus so I don't screw up regular pointing devices. Altering xorg.conf (which is surprisingly bare) with the recommended sections (adding sections for each of the stylus buttons) does nothing. I'm running crunchbang, which is an ubuntu/debian varient with openbox as the windows manager. Thanks Also, as a seperate note, does anybody know how to detect when I rotate and/or latch the lid shut? I was thinking maybe I could run a script to switch the buttons when I close it, but I can't find any information.

    Read the article

  • vDS - vCenter Problem

    - by rbmadison
    We are implementing a vSphere farm and are using a distrubuted switch. The VC is a VM within the farm connected to the distrubuted switch. We had a SAN issue and all of our VMs were down. When the SAN recovered and we restarted the ESX host containing the VC the VC couldn't connect to the network through the vDS. We had to remove a NIC from the vDS on that host and create a regular vswitch and then connect the VC to that before the VC would connect to the network. Is this typical behavior? If the VC goes down does all vDS networking stop on all the hosts? That seems to be a very bad thing. I thought networking would work even though the VC is down because the hosts have the vDS configuration cached. Is there a better way to configure it to prevent this from happening. We want to keep the VC as a VM for HA and recoverabilty purposes. Can anyone offer suggestions or explanations? I appreciate the help. Thanks, Rick

    Read the article

  • Misconfigured external monitor on Mac OS X Snow Leopard 10.6.3

    - by Mike
    I have an external monitor (specifically, an HDTV) hooked up to my 2.53GHz 13" macbook pro. This display works fine and I use it with my mac in clamshell mode (eg. with an external keyboard/mouse and the laptop closed and the built-in mac screen turned off) My Mac has multiple users on it. For User A I can use the mac with the external monitor in both clamshell and dual-monitor setups. For User B, I can use the monitor in a dual-monitor setup, but whenever I switch to clamshell mode the Mac switches to an incorrect output resolution or frequency setting that my HDTV doesn't recognize, resulting in a blank screen and a message about Unsupported Resolution. Chances are I did this to myself by misconfiguring my display settings at some point in the past, but I have no idea how to undo it. I (obviously) can't seen the display to change the settings when it's borked. I can see the display settings if I switch to Dual-monitor mode, but those settings only affect the dual monitor setup; no matter how I change the settings in dual-monitor mode, the clamshell mode setup remains borked. How can I dig myself out of this hole?

    Read the article

  • Shadow copy referencing invalid volume from symboliclink

    - by ccook
    I recently replaced my motherboard after the last one failed (was shorting and causing random reboots). I'm sure this was not healthy for the machine, and that a clean install would do wonders, but I'd like to fix the current install. That aside, I've been tracking down a pair of errors in the application log. Volume Shadow Copy Service error: Error calling a routine on a Shadow Copy Provider {b5946137-7b9f-4925-af80-51abd60b20d5}. Routine details IVssSnapshotProvider::QueryVolumesSupportedForSnapshots(ProviderId,29,...) [hr = 0x80042302, A Volume Shadow Copy Service component encountered an unexpected error. Check the Application event log for more information. ]. Operation: Query volumes supported by this provider Context: Provider ID: {b5946137-7b9f-4925-af80-51abd60b20d5} Snapshot Context: 29 Followed by Volume Shadow Copy Service error: Unexpected error calling routine Error calling CreateFile on volume '\?\Volume{f4bda86e-049d-11e1-9255-bcaec56690a1}\'. hr = 0x80070020, The process cannot access the file because it is being used by another process. This error is reproducible at command line, creating the two event log entries C:\Windows\system32>vssadmin list volumes vssadmin 1.1 - Volume Shadow Copy Service administrative command-line tool (C) Copyright 2001-2005 Microsoft Corp. Error: The shadow copy provider had an unexpected error while trying to process the specified command. Using WinObj from Sysinternals, I have tracked down the global object. '\?\Volume{f4bda86e-049d-11e1-9255-bcaec56690a1}\' - SymbolicLink - '\Device\HarddiskVolume8' Running DISKPART, and running the command "list volume" within it lists volumes 0 through 6, there is not a HarddiskVolume8. How can I remove this reference to HarddiskVolume8, and get shadow copy up and running?

    Read the article

  • Cisco Catalyst 4500 Policy Based Routing

    - by Logan
    In order to test a new firewall I just set up I'm trying to implement policy based routing on our core switch. I want traffic from certain vlans to be routed to the new firewall while everything else continues being routed through the old firewall. I was trying to use this guide. Everything from that guide works fine except trying to run the "ip policy route-map" command in the interface configuration mode. IOS is telling me that such a command doesn't exist. A "show ip interface vlan" command says that policy routing is disabled. Any ideas? Output of "show ver": Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500-IPBASEK9-M), Version 12.2(53)SG, RELEASE SOFTWARE (fc3) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2009 by Cisco Systems, Inc. Compiled Thu 16-Jul-09 19:49 by prod_rel_team Image text-base: 0x10000000, data-base: 0x11D1E3CC ROM: 12.2(31r)SG2 Dagobah Revision 226, Swamp Revision 34 RTTMCB2223-1 uptime is 3 years, 22 weeks, 2 days, 19 hours, 28 minutes Uptime for this control processor is 51 weeks, 2 days, 18 hours, 2 minutes System returned to ROM by power-on System restarted at 19:22:02 UTC Tue Jul 12 2011 System image file is "bootflash:cat4500-ipbasek9-mz.122-53.sg.bin" ... cisco WS-C4510R (MPC8245) processor (revision 4) with 524288K bytes of memory. Processor board ID FOX103703W3 MPC8245 CPU at 400Mhz, Supervisor V Last reset from PowerUp 42 Virtual Ethernet interfaces 244 Gigabit Ethernet interfaces 511K bytes of non-volatile configuration memory. Configuration register is 0x2

    Read the article

  • Win 7: apps crash, then explorer crashes, then services fail, then boom

    - by snorfys
    Periodically, every 2-3 days one of my systems will go haywire: every app will crash search will fail via the start menu and then explorer will fail. Restarting explorer via taskmanager will cause it to fail again, then it'll BSOD and restart. The eventlog for when this happens goes something like this every time: ERROR: Session "ReadyBoot" stopped due to the following error: 0xC0000188 (supposedly not a problem) WARNING: The maximum file size for session "ReadyBoot" has been reached... (forget where I found out, but also 'not a problem') ERROR: Session "Circular Kernel Context Logger" stopped due to the following error: 0xC0000188 (again, supposedly not a problem) WARNING: The maximum file size for session "Circular Kernel Context Logger" has been reached... ERROR: Faulting application name: Explorer.EXE, version: 6.1.7600.16450, time stamp:... ERROR: Faulting application name: explorer.exe, version: 6.1.7600.16450, time stamp:... ERROR: Faulting application name: svchost.exe_iphlpsvc, version: 6.1.7600.16385, time stamp:... ERROR: The Service Name service terminated unexpectedly. It has done this 1 time(s) That last one happens a number of times but with a different service name. Then finally we have: ERROR: The Service Control Manager tried to take a corrective action (Restart the service) after the unexpected termination of the Server service, but this action failed with the following error: An instance of the service is already running. After that, I have my BSOD and logs complaining that windows started up without shutting down. It's a new machine: Intel i3 530 4gb RAM (Ran memtest for 4 hrs, no problems) 320GB WD/250GB Seagate HDDs (Happened on fresh installs on 2 separate HDDs) Win7 Pro/Ultimate x64 (wife's copy of pro, my copy of ult, no change) Fresh install + driver and windows update (happened without updates as well) I'm at a bit of a loss as to what I can look at next. Especially since it'll work like a charm for 2-3 days and then it's hooped for a night (I'm on it now in fact - no problems).

    Read the article

  • Desktop virtualization

    - by gurpal2000
    Is there currently a proper Type 1 "desktop" hypervisor? Either free or not? This is just for tinkering around at home on some beefy Phenom machines. Basically i want to be able to run say 2 OSs on the same PC but without loading windows or a heavy flavour of linux and then use a hotkey to switch between them. I should get full performance out of them. So do i need something better than vmware workstation and/or virtualbox. I think these are "Type 2"? I already run VMWare w/s and VBox but is there a more performant solution? I saw a YouTube video from Citrix where a laptop was running XP and Vista. With the touch of a hot key they could switch between them. There was no visible underlying OS (there might be a hypervisor)? I have access to Citrix XenDesktop 3 enterprise edition evaluation. I realise this isn't for desktops but can i achieve my goal (geekiness) ? If i use the free XenServer 5.5.0 how do my client PCs access windows/linux/whatever from the xenserver? Is it via a thin client RDP type application? If so if there one for both windows and linux? Also if i do use XenServer can i use USB in either direction? What is Citrix receiver can i use that for (3) ? If so, is there some hotkey i can configure? whatever client is used to access the server software (whether it be on a different server or local) can i get full opengl/directx acceleration? what about Xen? i tried the Xen LiveCD but no clue as how to configure it. As you can see much confusion. Any help/pointers welcome. Cheers.

    Read the article

  • SELinux blocking Samba directory listing

    - by Sean M
    I am running Samba on a CentOS server, and I am experiencing a problem where it allows me to connect to the server and see a share, but shows the share as an empty directory. I find this behavior strange. Here is the stanza in my smb.conf for the given share: [seanm] path = /home/seanm writeable = yes valid users = seanm, root read only = No Here's what I see on the server side: [seanm@server ~]$ ls -l -rw-r--r-- 1 seanm seanm 40 Jan 4 13:45 pangram.txt And yet: [seanm@client ~]$ smbclient //server/seanm -U seanm -W WORKGROUP Enter seanm's password: Domain=[WORKGROUP] OS=[Unix] Server=[Samba 3.0.33-3.29.el5_5.1] smb: \> ls . D 0 Fri Jan 7 10:08:55 2011 .. D 0 Fri Jan 7 07:58:31 2011 58994 blocks of size 262144. 50356 blocks available This behavior is present on both a Windows client and a Linux client system. The behavior is present with the firewall on and with the firewall off, so it's not that. Neither /var/log/messages nor /var/log/secure have any complaints about Samba. I doubt that SELinux is a problem: just in case, here are the relevant settings. [root@server ~]# getsebool -a | grep samba samba_domain_controller --> off samba_enable_home_dirs --> on samba_export_all_ro --> off samba_export_all_rw --> off samba_share_fusefs --> off samba_share_nfs --> off use_samba_home_dirs --> on virt_use_samba --> off What am I doing wrong here, and what can I do to fix it? Edit: SELinux probably is the problem, judging by the fact that the issue goes away when I set SELinux to "permissive" or issue setsebool -P samba_export_all_rw on - both of which are unacceptable for production environments. What the heck kind of context does a directory need to have on it for Samba users to actually get files from it? I consider rolling your own rules and/or context to be deeply sub-optimal.

    Read the article

  • 10Gbe sfp+ Cross Over Cable required? Is there such a thing?

    - by dc-patos
    To preface, this is my first experience with 10GBe networking and I have encountered an issue which research does not seem to document a solution for... I have two servers (older DL580G5 and DL380G5), each with a HP NC522SFP 10Gbe dual sfp+ port adapter. I have purchased copper "passive" direct connect adapter cables (which look like twinax), which seem to work well when I connect them to the sfp+ ports on my Dell 5524 switch. However, if I directly connect the two servers with the same cable, the link doesn't come up. I am running WS2012 standard on each server. My intention is to use one of these servers as a home brew SAN and I would like to enable mutiple 10Gbe paths for iSCSI traffic. My question(s): Can I connect the two adapters to each other, such as I would with other less speedy generations of ethernet? If I can, do I require a crossover cable, or some type of other sfp+ cable solution to do this? My 10Gbe sfp+ switch ports are premium, but server to server connections are doable in small numbers for me and I would really like the multiple paths this would give me. Is there a simple solution?

    Read the article

  • switching dns server providers

    - by Yoav Aner
    I'm trying to wrap my head around something that I thought I kinda understood, but clearly there's some piece missing. We're currently using Zerigo as our primary dns, with slave dns running on linode. This works quite well. However, recent DDOS attacks on zerigo meant that whilst dns queries were still resolved, we were unable to make any dns changes. Since we rely on dns changes on our own infrastructure, I'm looking to improve this somehow. I'd rather not ditch zerigo completely, and realise that this or similar problems can happen with ANY primary dns hosting provider. It might not be DDOS, but a bug on their server, or something that means we can no longer issue updates. For this I want to have some fallback option: a completely independent (primary) dns provider (maybe AWS), which we will keep in-sync manually. We will switch-over to it when there's a problem. This brings me to my question: How do I make sure we can switch those providers quickly enough? specifically, on our registrar, there's a list of name servers, but no settings like TTL etc. How do dns clients know to use the newly updated name server records? Is this configured in the SOA? However, the SOA itself is hosted with the dns provider and we might not be able to update it... This is not a question about a one-time move, which can be planned and scheduled and tested, but rather to be able to do so when things are half-broken.

    Read the article

  • Add and remove letterhead in Word document

    - by Daniel Wolf
    Our company has letterheaded paper (pre-printed paper with our logo on it). Whenever we send something out by mail, we print it on that paper. However, when we send the same document via email, we convert it to a PDF file. Now the problem is: when converting a Word document to PDF, it should contain the letterhead. When printing the same document on paper, it should not (or else the letterhead would be printed twice). Currently, we are using two different Word document templates - one with letterhead, one without. So whenever we want to add or remove the letterhead, we have to create a new document with the other template and copy and paste everything over. Nasty solution. What I'm looking for is some simple way to switch the letterhead on and off. What I've tried so far: Switching the template: There does not seem to be a simple way to switch the template for an existing document. Using a picture watermark: Our letterhead goes all the way to the border of the page. (No printer supports this, of course, but it is fine for export to PDF.) Apparently depending on the current default printer, Word will not allow a borderless watermark, instead shifting the image around. Using the page header: When editing the page header, I can insert pictures at arbitrary positions, which is great. However, I could not find a way (short of macros) to enable/disable just the pictures in the header. (The text should remain there.)

    Read the article

  • OpenVZ with brdiged interfaces and VLAN

    - by Deimosfr
    Hi, I've got a problem with OpenVZ with brdiged VLAN. Here is my configuration : +------+ +-------+ +-----------+ +---------+ br0 |VE101 | | | | OpenBSD |----->| Debian |------->| | | WAN |--->| Router | | OpenVZ | +------+ | | | Firewall |----->| br0 br1 | br1 +------+ +-------+ +-----------+ +---------+------->|VE102 | |br0 | | |VLAN br0.110 +------+ v +---------+ |VE103.110| +---------+ I can't make VLAN working on br0 (br0.110) and I would like to understand why. I don't have any switch so no problem with unmanageable switch. I've configured a VLAN interface on OpenBSD in /etc/hostname.vlan110 : inet 192.168.110.254 255.255.255.0 NONE vlan 110 vlandev sis1 And it seams working fine. I've also adapted my PF configuration to work with VLAN but I don't see any incoming traffic. On my Debian lenny, here is my interfaces configuration : # The loopback network interface auto lo iface lo inet loopback # br0 auto br0 iface br0 inet static address 192.168.100.1 netmask 255.255.255.0 gateway 192.168.100.254 network 192.168.100.0 broadcast 192.168.100.255 bridge_ports eth0 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off # VLAN 110 auto br0.110 iface br0.110 inet static address 192.168.110.1 netmask 255.255.255.0 network 192.168.110.0 gateway 192.168.110.254 broadcast 192.168.110.255 pre-up vconfig add br0 110 post-down vconfig rem br0.110 It looks like ok, but when I start my VE, here is the message : ... Configure veth devices: veth103.0 Adding interface veth103.0 to bridge br0.110 on CT0 for VE103 can't add veth103.0 to bridge br0.110: Operation not supported VE start in progress... So I've got one error here. I've followed this documentation http://wiki.openvz.org/VLAN but it doesn't work. I've certainly missed something but I don't know why. Someone could help me please ? Thanks

    Read the article

  • Measure Total Bandwidth for Billing

    - by TonyZ
    I am setting up a new network which customers will host their applications on. It needs to be able to scale out to a few hundred servers and each server will have several VMs on it. Right now in my test environment, after the telco router, we are using a Linux router/firewall which is then connected to a Layer 2 switch. Could be a layer 3 in the future. I need to track total bandwidth per VM for each machine, and I need to do it in a way that it is not part of the VM. Each VM will have a private class ip address which is Natted by the gateway, or we may eventually run more than firewall/reverse proxy off a layer 3 switch. So my thinking is that I can do it off of a promiscuous port on the switches, or at the gateway firewall. I would like to have an out of the box solution, preferably open source. Does anyone have suggestions on the easiest way to set this up, and the easiest tool to use. I have looked at the web sites for Nagios, Zenoss, Zabbix, ntops on the firewall, etc. It is hard to ascertain just from the web sites if they do exactly this or not. Obviously, performance is also somewhat key here. Anything running on the gateway should not drag it down doing traffic accounting. Thanks for any thoughts. Tony Zakula

    Read the article

  • Disabling Keyboard Wakeup for Ubuntu 10.04 on Acer 1810TZ

    - by sybreon
    My Acer Aspire 1810TZ laptop suspends fine but wakes up on any slight key-press. I would like to disable this behaviour. I read that it involves disabling something in the /proc/acpi/wakeup but SLPB does not seem to be listed at all. root@1810TZ:/etc# cat /proc/acpi/wakeup Device S-state Status Sysfs node UHC0 S3 disabled pci:0000:00:1d.0 UHC1 S3 disabled pci:0000:00:1d.1 UHC2 S3 disabled pci:0000:00:1d.2 UHCR S3 disabled EHC1 S3 disabled pci:0000:00:1d.7 UHC3 S3 disabled pci:0000:00:1a.0 UHC4 S3 disabled UHC5 S3 disabled EHC2 S3 disabled pci:0000:00:1a.7 EXP1 S4 disabled pci:0000:00:1c.0 PXSX S4 disabled pci:0000:01:00.0 EXP2 S4 disabled PXSX S4 disabled EXP3 S4 disabled PXSX S4 disabled EXP4 S4 disabled pci:0000:00:1c.3 PXSX S4 disabled pci:0000:02:00.0 EXP5 S4 disabled PXSX S4 disabled EXP6 S4 disabled PXSX S4 disabled However, the relevant bits seem to be detected from dmesg. [ 0.357628] ACPI: AC Adapter [ACAD] (on-line) [ 0.357749] input: Power Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0C:00/input/input0 [ 0.357754] ACPI: Power Button [PWRB] [ 0.357817] input: Lid Switch as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0D:00/input/input1 [ 0.359319] ACPI: Lid Switch [LID0] [ 0.359390] input: Sleep Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0E:00/input/input2 [ 0.359394] ACPI: Sleep Button [SLPB] [ 0.359475] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input3 [ 0.359479] ACPI: Power Button [PWRF] Not quite sure what to do next.

    Read the article

  • Which is the fastest way to move 1Petabyte from one storage to a new one?

    - by marc.riera
    First of all, thanks for reading, and sorry for asking something related to my job. I understand that this is something that I should solve by myself but as you will see its something a bit difficult. A small description: Now Storage = 1PB using DDN S2A9900 storage for the OSTs, 4 OSS , 10 GigE network. (lustre 1.6) 100 compute nodes with 2x Infiniband 1 infiniband switch with 36 ports After Storage = Previous storage + another 1PB using DDN S2A 990 or LSI E5400 (still to decide) (lustre 2.0) 8 OSS , 10GigE network 100 compute nodes with 2x Infiniband Previous experience: transfered 120 TB in less than 3 days using following command: tar -C /old --record-size 2048 -b 2048 -cf - dir | tar -C /new --record-size 2048 -b 2048 -xvf - 2>&1 | tee /tmp/dir.log So , big problem here, using big mathematical equations I conclude that we are going to need 1 month to transfer the data from one side to the new one. During this time the researchers will need to step back, and I'm personally not happy with this. I'm telling you that we have infiniband connections because I think that may be there is a chance to use it to transfer the data using 18 compute nodes (18 * 2 IB = 36 ports) to transfer the data from one storage to the other. I'm trying to figure out if the IB switch will handle all the traffic but in case it just burn up will go faster than using 10GigE. Also, having lustre 1.6 and 2.0 agents on same server works quite well, with this there is no need to go by 1.8 to upgrade the metadata servers with two steps. Any ideas? Many thanks Note 1: Zoredache, we can divide it in two blocks (A)600Tb and (B)400Tb. The idea is to move (A) to new storage which is lustre2.0 formated, then format where (A) was with lustre2.0 and move (B) to this lustre2.0 block and extend with the space where (B) was. This way we will end with (A) and (B) on separate filesystems, with 1PB each.

    Read the article

  • VMWare converter performance

    - by bellocarico
    Hello, I have a question about my test lab. It's more to understand the concept more than apply this into production: I have an ESXi with few VMs linux/windows configured and I'd like to use VMWare converter to create backups. To speedup the process I decided to create a Windows VM on the same ESXi host where I've installed Windows 7 and VMWare Converter. The Host has a gigabit card but it's currently connected to a 100Mb FD port. Windows 7 sees a 1gb card connected. When I do the backup using VMWare converter I specify the host IP as source and destination, so I thought the copy could be faster then use my laptop across the network. Well, to cut a long sotry short: I get dreadful performance (4Mb/sec). I'm a buit confused on this because despite the fact that the host is running 100Mb communication between VMs and hosts shouldn't (correct me if I'm wrong) have any limitation instead. I did tweak windows 7 to optimise network performane but I got just a little improvement. i still need 4 hours to back up a 50Gb (thin) VM. Additionally I wanted to ask: Would jumbo frame help in this? I know that jumbo frame have to be supported end to end, and the network switch where the host is currently connected doesn't support this, but I was wondering: 1) Does ESXi host support jumbo frames at all? 2) Can I enable it somehow? 3) If I do so, I guess bulk transfert between VMs and host would improve, but would this affect the communication going through the real switch as this doesn't do jumbo? Thanks for reading

    Read the article

< Previous Page | 194 195 196 197 198 199 200 201 202 203 204 205  | Next Page >