Search Results

Search found 16034 results on 642 pages for 'context switch'.

Page 199/642 | < Previous Page | 195 196 197 198 199 200 201 202 203 204 205 206  | Next Page >

  • NIC are not advertising Correct Speeds

    - by Squidly
    I have an IBM x336 that is not advertising the proper LINK speeds. One interface is the other is not. I've tried to Force it to 1000/Full but then it just shows link down. I have confirmed the switch is set to auto negotiate like my switches. I have also changed out my Ethernet Cables. I'm at a loss where to look further. I have verified that it will connect at 1G on a different swtich. This also has happened on two different servers on the same switch. This is my output from mii-tool -v for each interface. eth0: negotiated 100baseTx-FD, link ok product info: vendor 00:08:18, model 24 rev 0 basic mode: autonegotiation enabled basic status: autonegotiation complete, link ok capabilities: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD advertising: 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD flow-control link partner: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD eth1: negotiated 1000baseT-FD flow-control, link ok product info: vendor 00:08:18, model 24 rev 0 basic mode: autonegotiation enabled basic status: autonegotiation complete, link ok capabilities: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD advertising: 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD flow-control link partner: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD

    Read the article

  • Why is my connection slow?

    - by Jay R.
    I have a Dell Precision T5400 with a Broadcom 1Gb onboard NIC. For some strange reason, when I access machines on our local network, the best I can get is around 125KB/s download speed. My laptop that has a 10/100Mb NIC onboard usually gets around 300KB/s or better from the same network resource. Both machines are plugged into the same 1Gb switch which connects to our local network wall jack at 100Mb half duplex. There is also a printer plugged into the same switch at 100Mb full. The resource I'm using for the test is a 30MB zip file copied from a jetty webserver that is running as part of a cruisecontrol installation. The cruisecontrol installation is running WindowsXP with full real-time antivirus and Altiris patch management and inventory running. That stuff on its own is eating some of the download speed. I've seen the laptop reach into the multiple MB/s download speed before, but the desktop never seems to get past 125KB/s to 130KB/s. In WindowsXP, before I upgraded the driver in the desktop, it was that slow. In Fedora, it is still slow even though it appears to be using the same driver version as the upgraded Windows driver. The upgraded Windows driver is faster, but still not nearly as fast as the laptop. What gives? Any insight to improve the situation would be appreciated. Could it be that the BroadCom board just isn't that good, or the driver in linux is just not as good as the Windows one?

    Read the article

  • How to best tune my SAN/Initiators for best performance?

    - by Disco
    Recent owner of a Dell PowerVault MD3600i i'm experiencing some weird results. I have a dedicated 24x 10GbE Switch (PowerConnect 8024), setup to jumbo frames 9K. The MD3600 has 2 RAID controllers, each has 2x 10GbE ethernet nics. There's nothing else on the switch; one VLAN for SAN traffic. Here's my multipath.conf defaults { udev_dir /dev polling_interval 5 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout none path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes # prio rdac } blacklist { device { vendor "*" product "Universal Xport" } # devnode "^sd[a-z]" } devices { device { vendor "DELL" product "MD36xxi" path_grouping_policy group_by_prio prio rdac # polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And iscsid.conf : node.startup = automatic node.session.timeo.replacement_timeout = 15 node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 10 node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 After my tests; i can barely come to 200 Mb/s read/write. Should I expect more than that ? Providing it has dual 10 GbE my thoughts where to come around the 400 Mb/s. Any ideas ? Guidelines ? Troubleshooting tips ?

    Read the article

  • Disabling Keyboard Wakeup for Ubuntu 10.04 on Acer 1810TZ

    - by sybreon
    My Acer Aspire 1810TZ laptop suspends fine but wakes up on any slight key-press. I would like to disable this behaviour. I read that it involves disabling something in the /proc/acpi/wakeup but SLPB does not seem to be listed at all. root@1810TZ:/etc# cat /proc/acpi/wakeup Device S-state Status Sysfs node UHC0 S3 disabled pci:0000:00:1d.0 UHC1 S3 disabled pci:0000:00:1d.1 UHC2 S3 disabled pci:0000:00:1d.2 UHCR S3 disabled EHC1 S3 disabled pci:0000:00:1d.7 UHC3 S3 disabled pci:0000:00:1a.0 UHC4 S3 disabled UHC5 S3 disabled EHC2 S3 disabled pci:0000:00:1a.7 EXP1 S4 disabled pci:0000:00:1c.0 PXSX S4 disabled pci:0000:01:00.0 EXP2 S4 disabled PXSX S4 disabled EXP3 S4 disabled PXSX S4 disabled EXP4 S4 disabled pci:0000:00:1c.3 PXSX S4 disabled pci:0000:02:00.0 EXP5 S4 disabled PXSX S4 disabled EXP6 S4 disabled PXSX S4 disabled However, the relevant bits seem to be detected from dmesg. [ 0.357628] ACPI: AC Adapter [ACAD] (on-line) [ 0.357749] input: Power Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0C:00/input/input0 [ 0.357754] ACPI: Power Button [PWRB] [ 0.357817] input: Lid Switch as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0D:00/input/input1 [ 0.359319] ACPI: Lid Switch [LID0] [ 0.359390] input: Sleep Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0E:00/input/input2 [ 0.359394] ACPI: Sleep Button [SLPB] [ 0.359475] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input3 [ 0.359479] ACPI: Power Button [PWRF] Not quite sure what to do next.

    Read the article

  • Outlook won't re-connect to exchange after network is re-connected

    - by stan503
    I have a setup at my desk where I connect my computer to a an RJ45 switch that switches between two networks. One network is the corporate network, which is maintained by my company's IT, and the other is my own private network where I do testing (the two networks have to be separated). The corporate network hosts the exchange server where I get e-mail. When I switch from the private network to the corporate network, I expect Outlook to re-connect to the exchange server. However, I have found that sometimes when I come back, Outlook take an extremely long time to re-connect. Send/Receive will give me back the error 'The server is not available' (0x8004011D). It will sit there for 10 minutes to a few hours before it finally re-connects. The only other option is to reboot my computer, which is a huge pain for me since I run multiple VMs on it. This usually happens when I'm connected to the private network for a significant amount of time, so I'm thinking it's because Outlook has cached the network status. Is there a way to force Outlook to do a 'hard' re-connect to the exchange server? I'm using Windows XP SP 3 with Outlook 2007.

    Read the article

  • FastGate A20 Line And Himem.sys Issue With Updating BIOS

    - by Boris_yo
    I have been persistent with a thought to perform my first BIOS update ever through MS-DOS but have been postponing this task until today. Despite people telling me any bootable ISO will do it either through CD-ROM or RAMDRIVE, I am still having problems. First is the problem with CD-ROM driver trying to make it work with 4 driver files (cd1.SYS, cd2.SYS, cd3.SYS, cd4.SYS) as well as starting RAMDISK proved to be failure: CD-ROM XMS Allocation Error RAMDISK XMS Allocaton Error (X: and R: drives not working) This A20 line seemed to be the obstacle which then after a couple of searches pointed me to this article on Microsoft website. It seems that FastGate is the culprit which takes over A20 line and conflicts with himem.sys which should be handling it causing the driver to be unable to allocate memory resources. Albeit article suggests 2 workarounds which is disabling FastGate option or adding switch, I read that the former workaround could cause problems which involves later tinkering BIOS, disabling shadow copy etc. while the latter workaround can just hang system as stated in the link above. I assume it just hangs the boot process from image file though. Summing up the above, I am cautious and think it is risky to follow both workarounds because disabling FastGate or trying adding switch by trying available switches from 1-14 or 16, could crash the BIOS update process by itself. I could do this without the need for himem.sys with bootable USB thumbdrive by making it to be seen as USB-HDD, but some time ago I read that it is never a good idea to update BIOS from hard drive so even thought it is simulation, who knows... Maybe it will deactivate hard drive in the middle of the BIOS update process or even USB thumbdrive per se? One forum discussion was about updating BIOS and somebody suggested to not load himem.sys for some reason, but now that I think of it, what if BIOS update needs upper memory?

    Read the article

  • Maintaining "Portability" Between Linux and Windows 7

    - by lokheart
    I am using the following ways in my office's Windows 7 machine to maintain my "portabilibity" when disaster strikes and I need to switch computer while I have no luxury of time for reinstalling all my program to the new PC. a majority of programs I used are portable, mostly from portableapp.com, like notepad+, GIMP, even R, I extract them and store them in a folder in My document, in a structure similar to the default portableapp installation when they are installed to a thumbdrive only a few software that portable version is not available and I will install them as usual all of my working files are stored in a folder in My document I regularly backup them all using syncback, because this program can keep versioning of my backup, and the backup is stored in a portable drive. One day I need to switch my computer and the operation is relative simple for me: I just move the two folders mentioned above into the my document folder of the new PC, install those few "non-portable" program in it, and this is almost done, some minor hiccups can be solved by reinstalling the portableapp into the drive. Overall speaking it is a smooth process. I would like to maintain the same degree of "portability" in my home Linux desktop (Ubuntu or Mint, I'm still deciding), that is, if my Linux crash and I need to reinstall it again. All I need to do is the move the two folder back to the new Linux, and most of my work will be almost ready to be worked on again. But I don't know how to find a Linux-alternative of portableapps. Being a newer to Linux, can anyone tell me whether this is possible in Linux?

    Read the article

  • How do I repair my Logitech Anywhere MX?

    - by Stefano Palazzo
    My Anywhere Mouse has got mushy mouse button syndrome. That is, the left mouse button feels a little bit soft, and it easily double clicks, let's go when I drag something. Before I repair it at home, rather than bringing it to the store (I kind of need it, it's the only one I have), I'd like to know exactly what I'm doing. It'd be too bad if I tried to repair it, voided the warranty and didn't succeed. I'm guessing there are screws to open it under the rubber pads. And I suppose I can take those off without breaking them, and put them back on without bending them. How is this mouse held together, and what's the safest way to open it? Once I have it open, will I be able to fix the problem? What's causing the mushy mouse button? Here's what I know so far: It might be the switch itself that's broken, in which case I shouldn't open it (I can't get a replacement, voiding the warranty to "have a look" seems pointless) If there are screws underneath the rubber pads, they're only on the 'front', the back two thirds of the mouse are all battery cover: There's nothing I can see under the batteries either. In the mouse I had before this one, there were sort of springy things connecting the actual button with the switch soldered to the board. They were just lying inside of a bit of plastic, and I could swap the left and right ones easily. If repairing it is more difficult, transferring the problem to the right mouse button would be a very good start.

    Read the article

  • Tooltips shadow stuck on desktop

    - by faulty
    I tends to get this problem from time to time. The tooltips with a shadow appearing on top of everything. It's the shadow of the tooltips not disappearing after the tooltips disappear. The last one I had the tooltips was from the wifi connection list at the systray. This problem also happen to me on another computer. Both running Win7 with ATI gpu. I found this similar post Menu command stuck on screen but none of the solution helped. In fact the "Fade or slide tooltips into view" has been unchecked from the beginning. Ending task of "dwm.exe" also doesn't help. So far the only way to resolve this by restarting window. I can't post picture yet, so can't show any screenshot. Edit: Just tested a few more trick which doesn't work. Turn of aero Hibernate Switch main display to external display and switch back. Change resolution Edit(heavyd): Here is a screenshot from my machine.

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • DNS failover in a two datacenter scenario

    - by wanson
    I'm trying to implement a low-cost solution for website high availability. I'm looking for the downsides of the following scenario: I have two servers with the same configuration, content, mysql replication (dual-master). They are in different datacenters - let's call them serverA and serverB. Users use serverA - serverB is more like a backup. Now, I want to use DNS failover, to switch users from serverA to serverB when serverA goes down. My idea is that I setup DNS servers (bind/powerdns) on serverA and serverB - let's call them ns1.website.com and ns2.website.com (assuming I own website.com). Then I configure my domain to use them as its nameservers. Both DNS servers will return serverA IP as my website's IP. If serverA goes down I can (either manually or automatically from serverB) change configuration of serverB's DNS, to return IP of serverB as website's IP. Of course the TTL will be low, as it's supposed to be in DNS failovers. I know that it may take some time to switch to serverB (DNS ttl, time to detect serverA failure, serverB DNS reconfiguration etc), and that some small part of users won't use serverB anyway. And I'm OK with that. But what are other downsides of such an approach? An alternative scenario is that ns1.website.com will return serverA IP as website's IP, and ns2.website.com will return serverB IP as website's IP. But AFAIK clients not always use primary nameserver and sometimes would use secondary one. So some small part of users would use serverB instead of serverA which is not quite what I'd like. Can you confirm that DNS clients behave like that and can you tell what percentage of clients would possibly use serverB instead of serverA (statistically)? This one also has the downside that when serverA goes back up, it will be automatically used as website's primary server, which is also a bad situation (cold cache, mysql replication could fail in the meantime etc). So I'm adding it only as a theoretical alternative. I was thinking about using some professional DNS failover companies but they charge for the number of DNS requests and the fees are very high (why?)

    Read the article

  • Setting Up My Home Network

    - by Skizz
    I currently have five PCs at home, three running WinXP and two running Ubuntu. They are set up like this: ISP ----- Modem ---- Switch ---- Ubuntu1 -- B&W Printer | |--WinXP1 | |--WinXP2 Wireless |--Colour Printer | |---------Ubuntu2 |---------WinXP3 (laptop) The Ubuntu1 machine is set up as a PDC using Samba and runs fetchmail, procmail, dovecot to get my e-mail and allow me to access the e-mail via imap so I can read the e-mail on any PC. I'd like to set up the network like this: ISP ----- Modem ---- Ubuntu1 ---- Switch ------WinXP1 | | |--WinXP2 B&W Printer Wireless |--Colour Printer | |---------Ubuntu2 |---------WinXP3 (laptop) My questions are: How to configure Ubuntu1 to act as a firewall. How to configure Ubuntu1 to provide a consistant user authentication across the network, at the moment Samba provides roaming profiles for the XP machines but the Ubuntu2 machine has it's own user lists. I'd like to have a single authentication for both XP machines and linux machines so that users added to the server list will propagate to all PCs (i.e. new users can log on using any PC without modifying any of the client PCs). How to configure a linux client (Ubuntu2 above) to access files on the server (Ubuntu1), some of which are in user specific folders, effectively sharing /home/{user} per user (read and write access) and stuff like /home/media/photos with read access for everyone and limited write access. How to configure the XP machines (if it is different from a the Samba method). How to set up e-mail filtering. I'd like to have a whitelist/blacklist system for incoming e-mails for some of the e-mail accounts (mainly, my kids' accounts) with filtered e-mails being put into quaranteen until a sysadmin either adds the sender to a blacklist or whitelist. OK, that's a lot of stuff. For now, I don't want config files*, rather, what services / applications to use and how they interact. For example, LDAP could be used for authentication but what else would be useful to make the administration of the LDAP easier. Once I have a general idea for the overall configuration, I can ask other questions about the specifics. Skizz I have looked around for information, but most answers are usually in the form of abstract config files and lists of packages to install.

    Read the article

  • GNU Screen and Finch Not Playing Nicely

    - by Sean M
    I use finch for instant messaging, and for persistence, finch is one of the things that runs in my screen session. There are three main computers that I access my screen session from, and each works at a different screen resolution. Because of the different resolutions, when I switch computers, I use screen -rd to attach to my screen session. Using screen -x results in problems. When I attach to the session, though, finch experiences display problems. I have to wait up to several minutes for finch to become responsive - it doesn't redraw properly at all. Trying to switch between chats just writes ^n and ^p, or ^(1-9) for numbers. It fixes itself after some time. Using ctrl-l does not help. Switching back and forth between screen windows does not help. This is an annoying behavior that I don't experience with any other applications running in screen. Is this a bug in screen or finch, and if not, what can I change about my configuration to correct it ? (would appreciate it if "finch" could be used as a tag for this instead of or in addition to "pidgin")

    Read the article

  • VMWare steals IP addresses

    - by Ishan Amin
    I'm having a peculiar problem, that I think I have narrowed down to VMware. For the past one year, every once in a while we lose internet connection and not all users (about 10 users) go down at the same time, its usually one-by-one. First someone will call me and say "Internet is down" and then we would go reset the router and modem and switch and it would be working again for a while, then go down again without any pattern or replicatable sequence. We'd go repeat the steps again to get everyone in the office running again. We called our Internet Service Provider and they constantly say, We see your modem and we see your router and from thier end everything is OK. we replaced our router and switch and modem, twice! Last friday, it dawned upon me, that everytime we turn on a VMware machine, this sequence of taking everyone down starts, which also explains the message that my users get for "IP Conflict Found" So we do alot of VMware testing and lo and behold, it takes my Internet down. My Yahoo and Gtalk would continue working but www is down when the VMware machines are started. I do use bridged networking to all the VMware machines, but I dont know what else to set it at. now, sorry for this long rambling but anyone have any clue on how to stop this? thanks IA

    Read the article

  • SeLinux blocking connection to sshd on Ubuntu 9.10

    - by Barton Chittenden
    When I try to log on to my laptop, which runs Ubuntu 9.10, the server rejects my login attempts. Checking /var/log/auth.log, I see the following: Feb 14 12:41:16 tiger-laptop sshd[6798]: error: ssh_selinux_getctxbyname: Failed to get default SELinux security context for tiger I googled for this, and ran across the following: http://www.spinics.net/lists/fedora-.../msg13049.html Here's the part that I think relates to the problem that I'm having: Quote: What's wrong on my system? Why it's not possible to login even if selinux is in permissive mode? Any suggestions? I'd start by trying to figure out why sshd isn't running in sshd_t (it seems to be running in sysadm_t). Paul. selinux mailing list selinux@xxxxxxxxxxxxxxxxxxxxxxx https://admin.fedoraproject.org/mail...stinfo/selinux Yes, sshd is running in sysadm_t: ps axZ | grep sshd system_u:system_r:sysadm_t 3632 ? Ss 0:00 /usr/sbin/sshd -o PidFile=/var/run/sshd.init.pi ls -Z /usr/sbin/sshd system_ubject_r:sshd_exec_t /usr/sbin/sshd Don't know why it's not sshd_t. I didn't modified something. It's a standard installation of sles11 with the default reference policy from tresys. Maybe this code snippet from policy/modules/services/ssh.te is responsible for that: Allow ssh logins as sysadm_r:sysadm_t gen_tunable(ssh_sysadm_login, true) Any ideas? Do you have boolean init_upstart set to on? if not try setting it to on. I do not believe ssh_sysadm_login boolean works currently but i may be mistaken. -- Yeah, setting init_upstart to on did the trick! THANK A LOT! Do you know why this prevents the user from logging in through ssh even if selinux is set to permissive?? Ok, so the million dollar question is "where do I set 'init_upstart=1'"? It's not clear from context which configuration file needs to be edited, and I'm not at all familiar with SELinux configuration.

    Read the article

  • Solaris 10 invalid ARP requests from 0.0.0.0? Link up/down every hour or 2

    - by JWD
    The guys at the data center where I'm hosting a server running Solaris 10 are telling me that my server is making a lot of invalid arp requests. This is an example of a portion of what was sent to me from the logs (with Mac addresses and IP addresses changed). [mymacaddress]/0.0.0.0/0000.0000.0000/[myipaddress]/[Datestamp]) It's being logged every hour. I don't see anything in the arp tables (arp -a) or routing tables (netstat -r) and I don't see anything relating to 0.0.0.0 when snoping the arp requests. The only place I see any reference to 0.0.0.0 is if I do netstat -a for the SCTP SCTP: Local Address Remote Address Swind Send-Q Rwind Recv-Q StrsI/O State ------------------------------- ------------------------------- ------ ------ ------ ------ ------- ----------- 0.0.0.0 0.0.0.0 0 0 102400 0 32/32 CLOSED But not really sure what that means. Doesn't seem like I can disable SCTP. There are some tunable SCTP parameters but it's not something I'm familiar with. Do I have to add changes to /etc/system? Looks like sctp_heartbeat_interval might be what I need to change? If it makes any difference, I have a few solaris zones running on this server, each with their own IP address on a virtual interface. eth0:0, eth0:1, etc. Does anyone have any idea what might be causing this and how to stop it? I think the switch I'm connected to doesn't like it and momentarily drops the connection. Is there anyway to at least block those requests using ipfilter or something else? Update: This was happening more frequently but now it seems to be happening roughly every hour or every two hours. It's not consistent. I tried setting setting the link speed and duplex to match the switch port and that seemed to make it stop happening for a few hours but then it started again.

    Read the article

  • 2 subnets off of 1 PC with 2 NICs

    - by Jeff
    I have a general setup I'd like to do with some IP cameras. This seems like it will work but I think I may be missing something. Our system consists of a video recorder PC connected to a switch which is connected to a number of IP cameras. I'd like to connect this system into an existing network but I want it on a different subnet. The main reason is that the cameras use a lot of bandwidth that I don't want slowing down the existing network. My idea was to install 2 NICs on the video recorder pc. 1 NIC connects to the existing network on 192.169.1.x for example, and the other NIC connect to the switch with the cameras. This NIC would be 192.168.100.x. Then we could remote to the video recorder PC with a GoToMyPC type thing for administration via the existing network. I've included a diagram of how I see this working but I'm a little fuzzy on the setup of the NICs (if this can work at all). My problem may be trying to deal with 2 subnets without a router but It really doesn't seem like it's necessary in this situation. BTW, gliffy is cool.

    Read the article

  • Looking for Remote Control that works with everything (even Windows 7 Media Center)

    - by T Reddy
    Using my Google-Fu, it seems that the most basic of things one gets with any DVR is the remote control. Had I known it would be difficult just to get a consumer IR receiver for Windows 7 I may not have bothered to build an HTPC. But too late, I already have the HTPC ready to go (minus the CETON card...) So I'm moving away from TiVo, I hate paying the monthly fees and my box is ancient. I'm looking for these solutions to my HTCP setup...I want to: Switch audio from HDMI to SPDIF via the remote control (i.e., switch from TV to Receiver) (as a side note, the built-in audio on the mobo has software to do this). Pressing the volume button on the remote will always change the TV's volume (or the Receiver's if possible) and NOT the PC's volume. The remote/receiver works well around 25 feet. Bonus if the IR Receiver can work with my existing TiVo remote (or other remotes laying around the house) I read a review of the Bluetooth TiVo remote...it sounds promising...but I'm not sure if it is great for Windows 7 HTPC?

    Read the article

  • Prevent Windows from resizing all the apps on the desktop when switching monitors

    - by Greg Hewgill
    Short version: When moving my laptop and sleeping between using different monitors, all my open windows are crammed into the upper left corner as if they tried to fit on the laptop internal screen resolution. I plug in and switch to the external monitor before unlocking my session. Is there a way to prevent this automatic resizing? Longer version: I have a laptop that I move between two locations. I have one docking station, and the same kind of monitor configured for 1600x1200, in both locations. The internal laptop screen is awful so I don't use it. Location A: Docking station, monitor connected via DVI. Location B: No docking station, external monitor connected via VGA cable. In this location I have the laptop lid open for keyboard access but I don't use the laptop screen. When moving from Location A to Location B, the laptop wakes up from sleep, displaying the screen on the internal monitor. I switch to the external monitor display (using Fn+F8 on this laptop), and only after that do I unlock my session with my password. However, Windows has crammed all my nicely arranged windows into the upper left corner as if it were trying to fit them all on the laptop internal screen resolution. When moving from Location B to Location A, I have the laptop lid closed when using the docking station so Windows apparently concludes the screen resolution is 1600x1200 and doesn't resize any windows. The laptop is a Dell Latitude running Windows 7 Professional.

    Read the article

  • How do I keep a bridge enabled on a bonded interface?

    - by jlawer
    I'm working on setting up a pair of CentOS 6.3 servers that will run a couple of KVM vms and have come across a problem setting up a bridge on a bond. I am using Mode 4 (802.3ad) bonding on a pair of stacked Dell Powerconnect 5524 switches connecting to R320 servers. There are 2 links (1 to each switch) that form a Link Aggregation Group (802.3ad / LACP bonding). On top of the bond I have VLAN Tagging. I've verified this is a problem on multiple other bonding modes so it isn't just a mode 4 issue. I am testing what happens when 1 link is dropped (ie switch dies, cable breaks, etc). If I don't have a bridge (for KVM), everything works fine, failover happens as expected. If I have the bridge enabled, it works fine until failover (unplugging a cable). When failover happens /var/log/messages shows the slave link going down, followed within a second by: kernel: br1: port 1(bond0.8) entering disabled state The thing is /proc/net/bonding/bond0 shows the link is up as expected (simply with only 1 slave instead of 2). If I plug the cable back in it recovers and brings the bridge back to an enabled state. I actually have tested this while a ping is occuring and if the timing is right a packet will actually leave the system after the link is lost, but before the disabled message occurs. This disabled state I assumed was STP, but I have disabled STP on the bridge configuration and this issue still occurs. brctl showstp br1 still shows the link as disabled when it is running without a slave. I also switched between the nics in the server (I have 2x Broadcom & 4x intel). It doesn't matter which configuration I have. Does anyone know of a way to force the bridge to stay enabled or why its detecting the bond as disabled, when it isn't?

    Read the article

  • Cisco 3560+ipservices -- IGMP snooping issue with TTL=1

    - by Jander
    I've got a C3560 with Enhanced (IPSERVICES) image, routing multicast between its VLANs with no external multicast router. It's serving a test environment where developers may generate multicast traffic on arbitrary addresses. Everything is working fine except when someone sends out multicast traffic with TTL=1, in which case the multicast packet suppression fails and the traffic is broadcast to all members of the VLAN. It looks to me like because the TTL is 1, the multicast routing subsystem doesn't see the packets, so it doesn't create a mroute table entry. If I send out packets with TTL=2 briefly, then switch to TTL=1 packets, they are filtered correctly until the mroute entry expires. My question: is there some trick to getting the switch to filter the TTL=1 packets, or am I out of luck? Below are the relevant parts of the config, with a representative VLAN interface. I can provide more info as needed. #show run ... ip routing ip multicast-routing distributed no ip igmp snooping report-suppression ! interface Vlan44 ip address 172.23.44.1 255.255.255.0 no ip proxy-arp ip pim passive ... #show ip igmp snooping vlan 44 Global IGMP Snooping configuration: ------------------------------------------- IGMP snooping : Enabled IGMPv3 snooping (minimal) : Enabled Report suppression : Disabled TCN solicit query : Disabled TCN flood query count : 2 Robustness variable : 2 Last member query count : 2 Last member query interval : 1000 Vlan 44: -------- IGMP snooping : Enabled IGMPv2 immediate leave : Disabled Multicast router learning mode : pim-dvmrp CGMP interoperability mode : IGMP_ONLY Robustness variable : 2 Last member query count : 2 Last member query interval : 1000

    Read the article

  • EMC VNX iSCSI setup - unsure about SP/port assignment

    - by pauska
    We have a new VNX5300 waiting to get configured, and I need to plan out the network infrastructure before the EMC tech arrives. It has 4x1gbit iSCSI per SP (8 ports in total), and I'd like to get the most out of the performance until we jump over to 10gig iSCSI. From what I can read from the docs - the recommendation is to use only two ports per SP, with 1 active and 1 passive. Why is this? It seems kind of pointless to have quad-port i/o-modules and then recommend to not use more than two of them? Also - I'm a bit unsure about the zoning. The best practices guide state that you should separate each port on each SP from each other on different logical networks. Does this mean that I have to create 4 logical networks to be able to use all 8 ports? It also gives the following example: Does this mean that A0 and B0 should sit on the same physical switch aswell? Won't this make all traffic go on one switch (if both A1 and B1 are passive)? Edit: Another brainpuzzle I don't get it - each host (as in server) should not have more iSCSI bandwidth available than the storage processor. What on earth does this matter? If serverA have 1gbit and serverB have 100mbit, then the resulting bandwith between them is 100mbit. How can this result in some kind of oversubscription? Edit4: Wait, what. Active and passive ports? The VNX runs in a ALUA configuration with asymmetrical active/active.. there shouldn't be any passive ports, only preferred ones..

    Read the article

  • Linux - preventing an application from failing due to lack of disk space [migrated]

    - by Jernej
    Due to an unpredicted scenario I am currently in need of finding a solution to the fact that an application (which I do not wish to kill) is slowly hogging the entire disk space. To give more context I have an application in Python that uses multiprocessing.Pool to start 5 threads. Each thread writes some data to its own file. The program is running on Linux and I do not have root access to the machine. The program is CPU intensive and has been running for months. It still has a few days to write all the data. 40% of the data in the files is redundant and can be removed after a quick test. The system on which the program is running only has 30GB of remaining disk space and at the current rate of work it will surely be hogged before the program finishes. Given the above points I see the following solutions with respective problems Given that the process number i is writing to file_i, is it safe to move file_i to an external location? Will the OS simply create a new instance of file_i and write to it? I assume moving the file would remove it and the process would end up writing to a "dead" file? Is there a "command line" way to stop 4 of the 5 spawned workers and wait until one of them finishes and then resume their work? (I am sure one single worker thread would avoid hogging the disk) Suppose I use CTRL+Z to freeze the main process. Will this stop all the other processes spawned by multiprocessing.Pool? If yes, can I then safely edit the files as to remove the redundant lines? Given the three options that I see, would any of them work in this context? If not, is there a better way to handle this problem? I would really like to avoid the scenario in which the program crashes just few days before its finish.

    Read the article

  • Can't find PC on network

    - by Simon Verbeke
    I just got myself a new laptop, and set it up. It is connected to the wireless internet in my home. I then wanted to create a homegroup between the laptop and my desktop, but they can't find each other. Probably because the desktop has a wired connection to the router and the laptop is connected to a wireless access point. The router and the AP are connected to a switch in the middle by cable. A sketch of the network: Laptop - - - Wireless Access Point ----- Switch ----- Router ----- Desktop ^ ^ ^ ^ Wireless Wired Wired Wired They both point to the same gateway and DHCP-server (on 192.168.0.1). And I can ping to that address from both PCs. When I try to ping either of the PCs the pings time out. The subnets are also the same (255.255.255.0) and the IPs are in the same range (192.168.0.114 laptop, 192.168.0.205 desktop). So I don't really understand what I need to do to be able to access either computer from the other. The weird thing is that Synergy (to use mouse and keyboard over the network) works, just by using the IPs assigned to both PCs. The acces point is a linksys WAP54g, but I'm unsure of the Router, it has a custom casing from our ISP and hides any clues for identifying the product. I'm going to google a bit so I can add that info later. Both PC's are Windows 7 64 bit. The desktop is Ultimate, the laptop Professional.

    Read the article

  • OpenVZ with bridged interfaces and VLAN

    - by Deimosfr
    Hi, I've got a problem with OpenVZ with bridged VLAN. Here is my configuration: +------+ +-------+ +-----------+ +---------+ br0 |VE101 | | | | OpenBSD |----->| Debian |------->| | | WAN |--->| Router | | OpenVZ | +------+ | | | Firewall |----->| br0 br1 | br1 +------+ +-------+ +-----------+ +---------+------->|VE102 | |br0 | | |VLAN br0.110 +------+ v +---------+ |VE103.110| +---------+ I can't make VLAN work on br0 (br0.110) and I would like to understand why. I don't have any switch so no problem with unmanageable switch. I've configured a VLAN interface on OpenBSD in /etc/hostname.vlan110: inet 192.168.110.254 255.255.255.0 NONE vlan 110 vlandev sis1 And it seems to be working fine. I've also adapted my PF configuration to work with VLAN but I don't see any incoming traffic. On my Debian Lenny, here is my interfaces configuration : # The loopback network interface auto lo iface lo inet loopback # br0 auto br0 iface br0 inet static address 192.168.100.1 netmask 255.255.255.0 gateway 192.168.100.254 network 192.168.100.0 broadcast 192.168.100.255 bridge_ports eth0 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off # VLAN 110 auto br0.110 iface br0.110 inet static address 192.168.110.1 netmask 255.255.255.0 network 192.168.110.0 gateway 192.168.110.254 broadcast 192.168.110.255 pre-up vconfig add br0 110 post-down vconfig rem br0.110 It looks OK, but when I start my VE, here is the message: ... Configure veth devices: veth103.0 Adding interface veth103.0 to bridge br0.110 on CT0 for VE103 can't add veth103.0 to bridge br0.110: Operation not supported VE start in progress... So I've got one error here. I've followed this documentation http://wiki.openvz.org/VLAN but it doesn't work. I've certainly missed something but I don't know why. Someone could help me please? Thanks

    Read the article

< Previous Page | 195 196 197 198 199 200 201 202 203 204 205 206  | Next Page >