  • Excel or OpenOffice Table Summary: how to reconstruct a table from another, with "missing" values

    - by Gilberto
    I have a table of values (partial) with 3 columns: month (from 1 to 12), code and value. E.g., MONTH | CODE | VALUE 1 | aaa | 111 1 | bbb | 222 1 | ccc | 333 2 | aaa | 1111 2 | ccc | 2222 The codes are clients and the values are sales volumes. Each row represents the sales for one month for one client. So I have three clients, namely aaa, bbb, and ccc. For month=1 their sales volumes are: aaa-111, bbb-222, and ccc-333. A client may or may not have sales for every month; for example, for the month 2, the client bbb has no sales. I have to construct a completed summary table for all the MONTH / CODE pairs with their corresponding VALUE (using the value from the "partial" table, if present, otherwise print a string "missing"). MONTH | CODE | VALUE 1 | aaa | 111 1 | bbb | 222 1 | ccc | 333 2 | aaa | 1111 2 | bbb | missing 2 | ccc | 2222 Or, to put it another way, the table is a linear representation of a matrix:                                 and I want to identify the cells for which no value was provided. How can I do that?

    Read the article

  • ffmpeg: video file played OK on Ubuntu, but no sound on XP

    - by Andy Le
    I created a video clip using ffmpeg (vcodec: mpeg2video, acodec: AC3 5.1). The file can be played normally on Ubuntu, but when I play it on an XP machine, there is no sound. I can play AC3 files and other movies with AC3 sound. I already tried many codec packs and many players. When I compare the MediaInfo tab of the Properties window of the file with another playable movie, I see that the Audio Identifier of the audio stream in my file is 0x80 while it is 0x02 in the other movie. So I guess that's why players on XP can't recognize the audio codec. When I use an MKV container instead of MPEG (still mpeg2video codec), then the result is OK on both Ubuntu and XP (with the correct Audio ID). I really need MPEG though. Any idea? This is the command I used: ~/ffmpeg/ffmpeg/ffmpeg -loop_input \ -t 97 -r 30000/1001 -i v%4d.tga -i final.ac3 \ -vcodec mpeg2video -qscale 1 -s 400x400 -r 30000/1001 \ -acodec copy -y out6.mpeg 2 This is the output of mediainfo (on Ubuntu): General Complete name : out6.mpeg Format : MPEG-PS File size : 6.86 MiB Duration : 1mn 37s Overall bit rate : 593 Kbps Video ID : 224 (0xE0) Format : MPEG Video Format version : Version 2 Format profile : Main@Main Format settings, BVOP : No Format settings, Matrix : Default Format_Settings_GOP : M=1, N=12 Duration : 1mn 37s Bit rate mode : Variable Bit rate : 122 Kbps Width : 400 pixels Height : 400 pixels Display aspect ratio : 1.000 Frame rate : 29.970 fps Resolution : 8 bits Colorimetry : 4:2:0 Scan type : Progressive Bits/(Pixel*Frame) : 0.025 Stream size : 1.41 MiB (21%) Audio ID : 128 (0x80) Format : AC-3 Format/Info : Audio Coding 3 Duration : 1mn 36s Bit rate mode : Constant Bit rate : 448 Kbps Channel(s) : 6 channels Channel positions : Front: L C R, Side: L R, LFE Sampling rate : 44.1 KHz Stream size : 5.18 MiB (75%)

    Read the article

  • Downmix surround to Dolby Pro-Logic at the OS/driver level in Windows 7?

    - by davr
    First off, I'm talking about Dolby Pro-Logic, a really old tech for encoding 4 audio channels (L/R/C/SR) into two analog outputs, and then extracting them again. It was used in surround sound systems in the last century. I have a modern PC that can output 5.1 analog audio (Three outputs on the back carry six channels of audio). But I have a really old surround sound reciever that only has a two-channel, L/R input, which it extracts 4 channels of audio from, and outputs to 5.1 speakers. What I want is some way for the OS, Windows 7, to act as if I really had 5.1 audio channels available, so applications produce surround audio, but before outputting it out of the back of my PC, apply Dolby Pro-Logic matrix encoding so that it outputs over only two channels. These two channels would then get sent to my receiver via a RCA cable, which would decode it again and drive the surround speakers. Is anything like this possible? I'm pretty sure I could do it at an application / codec level, but I'm looking for something that I just have to set once.

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    Hi All, I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: http://superuser.com/questions/12955/how-do-i-remove-the-option-to-eject-sata-drives-from-the-windows-7-tray-icon

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: How do I remove the option to eject SATA drives from the Windows 7 tray icon?

    Read the article

  • Notebook display problem (multiplication)

    - by SubniC
    Hi, I'm having some troubles with the display of a LG E500 notebook. The thing is that without any known reason the display starts to show the screen divided in eigth parts and each part show the display image as if I had a matrix of eigth displays :) I thought it could be some kind of refresh rate problem or driver related, but it is happening at boot-up as well and the BIOS. I got the computer completely unassambled yesterday and I check all the wires and connectors looking for something broken or unconected, but without luck... You can see a picture here of the problem (sorry for the low quality, but I think it illustrate the problem. EDIT 1: I uploaded a new pictrue, here you cans ee the problem better :) There are three horizontal lines that you can see just between the windows. You can see the grey line at the first moment you turn on the computer and the after the duplicated screens show up just like if they where arranged over a grid (over the horizontal lines...) I hope it makes any sense. Do you know what could be happening? or can you tell me what would you do? Thank you very much for your help.

    Read the article

  • Diagnosing RAM issues

    - by TaylorND
    I have an old Acer Aspire T180 desktop. The specs are as follows: AMD Athlon 64 3800+ 2.4GHz 1GB DDR2 SDRAM 160GB DVD-Writer (DVD±R/±RW) Gigabit Ethernet 17" Active Matrix TFT Color LCD Windows Vista Home Basic Mini-tower AST180-UA381B According to the information in the computer's documentation the computer comes with 1 GB of RAM. It has two DDR2 SDRAM sticks. I used to have Windows Vista installed. Then I removed it and install Windows 7, and now I have since removed Windows 7 and installed Windows XP. According to Windows XP with both RAM sticks in the computer has 768 MB. Isn't this supposed to be 1 GB of RAM or 1024 MB of RAM? Is the amount of RAM installed only partly used by the Operating System? Is there's something I'm missing? If I remove either one of the RAM sticks I'm left with 448 MB of RAM. These numbers don't seem to add up. If each of the RAM sticks contains at least 448 MB of RAM shouldn't they (both being in) provide 896 MB of RAM. Even then, isn't that less than a GB of RAM? I'm not too experienced in hardware so I thought this would be the best place to ask. As a follow up question, is the RAM I have enough to run/multitask with Windows XP efficiently? I plan to do a lot of computing with the system (although not gaming), should I invest in more RAM?

    Read the article

  • Formatting a former RAID 0 drive through USB

    - by EXC
    I'll try to be as specific as possible here: I was using two Hitachi 2.5" 500 gb HDDs in my Gateway P-7805u laptop in a RAID 0 configuration. The array was causing the laptop to run extremely hot, however, so I removed them and deleted the RAID array through Intel Matrix HDD manager. I did a clean install of Windows 7 on the original 320 gb HDD that came with the laptop. I never did format the original RAID array HDDs before taking them out of the computer. Now, I am attempting to format the Hitachi 500 gb RAID array HDDs externally through a USB external enclosure. The external HDD drivers install on my clean install OS, but when I go into 'My Computer' there is no external drive available. I cannot format in CMD Prompt because my computer will not designate a drive letter to the external HDD. The drivers install and the HDD is recognized as a Hitachi external drive, but nothing seems to show up in my computer window. I need to know if there is a way to format these drives to NTFS externally.

    Read the article

  • How Can I Bypass the X-Frame-Options: SAMEORIGIN HTTP Header?

    - by Daniel Coffman
    I am developing a web page that needs to display, in an iframe, a report served by another company's SharePoint server. They are fine with this. The page we're trying to render in the iframe is giving us X-Frame-Options: SAMEORIGIN which causes the browser (at least IE8) to refuse to render the content in a frame. First, is this something they can control or is it something SharePoint just does by default? If I ask them to turn this off, could they even do it? Second, can I do something to tell the browser to ignore this http header and just render the frame?

    Read the article

  • TeamCity error: svn: connection refused by the server

    - by chrisk
    We have a Continuous Integration environment setup with TeamCity and subversion. TeamCity gets the latest source from svn and does a build (Visual Studio) on every commit. Sometimes we get the following TeamCity error when the build runs. Doing a couple of force builds gets TeamCity running succesfully. Build errors [12:35:24]: Patch is broken, can be found in file: C:\TeamCity\buildAgent\temp\cache\temp6036patch_803[12:35:24]: RunBuildException when running build stage UpdateSourcesFromServer: Failed to build patch for build 519 {build id=803}, VCS root: svn: https://svn.myDomain.com/repos/myApplication {id=2}, due to error: org.tmatesoft.svn.core.SVNException: svn: connection refused by the server svn: REPORT request failed on '/repos/myApplication/!svn/vcc/default' Any ideas why this might be happening ?

    Read the article

  • Displaying Multiple Tables in a Page in Jasper Reports using ireports/Jasper Assistant

    - by Karthikeyan
    Hi all, I have a report to be printed / exported to PDF format. for that i am using jasper reports. I have 8 individual pages to be exported. so i prepared 8 separate design files. In that 6 pages are having more static text and mere direct mapping and remaining two pages consists of table like data. one page contains huge table so i filled it directly with no problem by keeping a single table in detail band. now problem is that remaining one page. that page is having more than 5 small tables (two or four column). is t possible to have more that one table in a page in jasper reports ? i am using jasper reports and for designing jasper assistant/ireports.

    Read the article

  • printing from crystal reports activex printcontrol gives needless error

    - by DaVinciCoder
    I've got an asp.net application running on a windows 2008 64 bit server that gives an error after printing a crystal report. The server has CR 2008 runtime sp2 installed and views fine. When printing from the print button of the CR viewer the print dialog appears and prints correctly but throws the following error message after printing. "An error occurred on the server. Printing will be stopped. Would you like to view the error information" there is a yes or no option that points to an empty html file called PrintControlError.html. Other then this issue I've got no other troubles.

    Read the article

  • RDLC filtering nested tables

    - by aprescott
    I am creating an RDLC report where the dataset consists of several datatables. There is one parent table and several child tables. What I would like to do is display relevant data from each child table for each row in the parent table. Here is a simplified example: table1 = "Purchase" has columns PurhcaseID, PurchaseNumber, PurchaseDate table2 = "PurchasedItem" has columns PurchaseItemID, PurhcaseID, ItemDescription In my RDLC, I have a Purchase table grouped on PurchaseDate and would like to display the PurchasedItems for each Purchase. The current solution uses a subreport, but I do not like this because it leaves an ugly empty space when there is no data for the subreport display. (I would be fine with using a subreport if I could properly hide it without leaving an empty space.) I am not able to rewrite the stored procedure to return a single table, either. How are others dealing with this scenario?

    Read the article

  • Running Xcode Applications without installing Xcode

    - by Cawas
    I know nothing about Xcode, except it's a Developer interface from Apple that actually comes on OSX CD and it's used to create iPhone apps as well. I also know it have a Applications folder, filled with little utilities, that are indeed quite useful. I tried grabbing one of them and running, without installing Xcode but it doesn't work. It brings an error and a Problem Report from which I believe the relevant part is this: Dyld Error Message: Library not loaded: @rpath/DevToolsInterface.framework/Versions/A/DevToolsInterface I've tried, of course, locating that "framework", with no success. Well... I guess it's probably possible to install Xcode, get that utility source, if it exists somewhere, and compile for stand-alone. But that goes beyond my point. I just want to know if there's somewhere I can get those utilities and/or make them run without needing to install Xcode at all.

    Read the article

  • Facebook connect - api_client->users_getInfo throws error Cannot use string offset as an array

    - by Gublooo
    Hey guys I have this piece of code which works 90% of the time: $user_details=$fb-api_client-users_getInfo($fb_user, array('last_name','first_name','proxied_email')); $firstName=$user_details[0]['first_name']; But sometimes I get this error: Fatal error: Cannot use string offset as an array for line $firstName=$user_details[0]['first_name']; I have read several people report the same issue - but I'm still not clear as to what is the reason - Am I getting this error because facebook is not returning any results or am I getting because it is returning only a single array instead of array of arrays. This is the fix I'm thinking of: if (!is_array($user_details)) { $firstName=''; } else { $firstName = ($user_details[0]) ? $user_details[0]['first_name'] : $user_details['first_name']; } Also if I'm not getting the name - is it because of a timeout issue or something else? Thanks

    Read the article

  • Embed SQL Password into Crystal Reports RPT file?

    - by codeulike
    We are experimenting with Crystal Reports viewers such as this one: http://www.thereportviewer.com/ ... which can actually re-connect to the data source and re-run a Crystal Reports RPT file with live data. However when running the report the viewer asks for a password to connect to the data source (in this case SQL Server). Does Crystal Reports have some way of embedding a connection password into a RPT file to avoid this? Or should I be using a System DSN from the Control Panel/ODBC thing to get around this? I figure someone else must have had this problem.

    Read the article

  • ASP.NET MVC FileContentResult IE 8.0 hangs on download

    - by marc.d
    some of my users are expieriencing problems when they try to download a report, the download just hangs on 0%, restarting IE usually fixes the problem. why does this happen? i am using ASP.NET MVC (v1), the my action looks like this <Authorize()> _ <AcceptVerbs(HttpVerbs.Get)> _ Function RenderReport(ByVal guid As Guid, ByVal anonym As Boolean) As FileContentResult ... Dim mimeType As String = String.Empty Dim renderedBytes() As Byte = EmployeePresentation.Render(guid, mimeType, Server.MapPath("~/Reports/..."), anonym) Return File(renderedBytes, mimeType, filename) End Function the filename is US-ASCII encoded, filesize is usally around 300Kb, mimeType is application/pdf tia

    Read the article

  • ASP.NET AJAX Problem

    - by Rich Andrews
    I've updated some code to use the Ajax Control toolkit 0911 beta and for some reason code that dynamically added collapsable panel extenders in the code behind now causes the following error in the client side jscript... Microsoft JScript runtime error: Sys.ArgumentException: Value must not be null for Controls and Behaviors. Parameter name: element in... $create = Sys.Component.create = function Sys$Component$create(type, properties, events, references, element) { /// <summary locid="M:J#Sys.Component.create" /> /// <param name="type" type="Type"></param> /// <param name="properties" optional="true" mayBeNull="true"></param> /// <param name="events" optional="true" mayBeNull="true"></param> /// <param name="references" optional="true" mayBeNull="true"></param> /// <param name="element" domElement="true" optional="true" mayBeNull="true"></param> /// <returns type="Object"></returns> var e = Function._validateParams(arguments, [ {name: "type", type: Type}, {name: "properties", mayBeNull: true, optional: true}, {name: "events", mayBeNull: true, optional: true}, {name: "references", mayBeNull: true, optional: true}, {name: "element", mayBeNull: true, domElement: true, optional: true} ]); if (e) throw e; if (type.inheritsFrom(Sys.UI.Behavior) || type.inheritsFrom(Sys.UI.Control)) { if (!element) throw Error.argument('element', Sys.Res.createNoDom); } I accept that this is only a beta but I'm unable to either find a work around or even understand the reason why this pretty simple code no longer works. Code private Panel GetReportPanel(DataRow dr, ReportParameter[] Params) { Panel pnlReport = new Panel(); pnlReport.ID = Uri.EscapeDataString(dr["ReportName"].ToString()) + "_MainReportContainer"; //Report Title Section var pnlReportTitle = new Panel(); pnlReportTitle.CssClass = "ReportSectionTitle"; var tblReportTitle = new Table(); var trowReportTitle = new TableRow(); var tcellReportTitle = new TableCell(); var imgReportTitleExpand = new Image(); imgReportTitleExpand.ID = Uri.EscapeDataString("img" + dr["ReportName"].ToString() + "DataExpand"); tcellReportTitle.Controls.Add(imgReportTitleExpand); trowReportTitle.Controls.Add(tcellReportTitle); tcellReportTitle = new TableCell(); var lblReportTitle = new Label(); lblReportTitle.ID = Uri.EscapeDataString("lnk" + dr["ReportName"].ToString()); lblReportTitle.Text = "Functional " + dr["ReportName"].ToString(); tcellReportTitle.Controls.Add(lblReportTitle); trowReportTitle.Controls.Add(tcellReportTitle); tblReportTitle.Controls.Add(trowReportTitle); pnlReportTitle.Controls.Add(tblReportTitle); pnlReport.Controls.Add(pnlReportTitle); //Report Section var pnlReportSection = new Panel(); pnlReportSection.ID = Uri.EscapeDataString("pnlReportSection" + dr["ReportName"].ToString()); pnlReportSection.CssClass = "ReportSection"; pnlReportSection.ScrollBars = ScrollBars.None; var pnlInnerReportSection = new Panel(); pnlInnerReportSection.CssClass = "ReportSection"; var rptControl = new ReportViewer(); rptControl.ID = "rpt" + dr["ReportName"].ToString().Replace(' ', '_'); rptControl.ProcessingMode = ProcessingMode.Remote; rptControl.Width = new Unit("100%"); rptControl.ShowDocumentMapButton = false; rptControl.ShowParameterPrompts = false; rptControl.Visible = true; rptControl.Height = new Unit("500px"); rptControl.AsyncRendering = (bool)dr["ASyncRenderingEnabled"]; rptControl.ServerReport.ReportPath = dr["SSRSReportPath"].ToString(); rptControl.ServerReport.ReportServerUrl = new Uri("http://horoap336/reportserver"); rptControl.ServerReport.SetParameters(Params); pnlInnerReportSection.Controls.Add(rptControl); pnlReportSection.Controls.Add(pnlInnerReportSection); pnlReport.Controls.Add(pnlReportSection); //Collapsable Panel Extender var Extender = new AjaxControlToolkit.CollapsiblePanelExtender(); Extender.TargetControlID = pnlReportSection.ID; Extender.ID = Uri.EscapeDataString(dr["ReportName"].ToString()) + "_Extender"; Extender.CollapsedSize = 0; Extender.Collapsed = true; Extender.ExpandControlID = lblReportTitle.ID; Extender.CollapseControlID = lblReportTitle.ID; Extender.AutoCollapse = false; Extender.AutoExpand = false; Extender.ScrollContents = false; Extender.TextLabelID = lblReportTitle.ID; Extender.CollapsedText = "Functional " + dr["ReportName"].ToString() + " (Click To Show Details...)"; Extender.ExpandedText = "Functional " + dr["ReportName"].ToString() + " (Click To Hide Details...)"; Extender.ImageControlID = imgReportTitleExpand.ID; Extender.ExpandedImage = "~/images/collapse.jpg"; Extender.CollapsedImage = "~/images/expand.jpg"; Extender.ExpandDirection = AjaxControlToolkit.CollapsiblePanelExpandDirection.Vertical; pnlReport.Controls.Add(Extender); return pnlReport; } This panel is then added to a panel in the aspx file using... pnlContainer.Controls.Add(GetReportPanel(dr,Params)); Aspx file... <%@ Page Title="Operations MI Dashboard - Functional Reporting" Language="C#" MasterPageFile="~/MasterPage.master" AutoEventWireup="true" CodeFile="FunctionalReport.aspx.cs" Inherits="TelephonyReport" %> <%@ Register Assembly="Microsoft.ReportViewer.WebForms, Version=9.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" Namespace="Microsoft.Reporting.WebForms" TagPrefix="rsweb" %> <asp:Content ID="Content1" ContentPlaceHolderID="head" Runat="Server"> </asp:Content> <asp:Content ID="Content2" ContentPlaceHolderID="ContentPlaceHolder1" Runat="Server"> <asp:Panel ID="pnlContainer" runat="server"> </asp:Panel> </asp:Content> So, my questions are: Is there a problem with my code that is only evident in the later version of the toolkit? Does anyone know of a workaround that I can try? Can anyone explain why this problem happens only in the latest version?

    Read the article

  • VS 2010 beta 2 Web ReportViewer Bug?

    - by rip
    The report viewer doesn't seem to work in asp.net projects in VS 2010. You get the following error: Microsoft Jscript runtime error: ‘Microsoft’ is undefined. VS also breaks on the following line of javascript code: $create(Microsoft.Reporting.WebFormsClient.ReportViewer, {"_internalViewerId":"ctl00_MainContent_ReportViewer1_ctl03","id":"ctl00_MainContent_ReportViewer1"}, null, null); Steps to recreate problem: In Visual Studio 2010 beta 2 create a new asp.net project Drag a ScriptManager control on to default.aspx Drag a ReportViewer control on to default.aspx Build and run the project You then get the problem Is this a bug or am I doing something wrong?

    Read the article

  • MSBuild cannot find SGen when compiling a solution

    - by Jaxidian
    I've looked at several other SGen-related questions on here and either their answers don't apply or their answers don't fix this for me. I have installed several SDKs to fix this issue with no luck. Reference types should not be changed since this is the only place this is a problem. Once suggestion is to put SGen.exe into the C:\Windows\Microsoft.NET\Framework\v3.5 folder, but that's not been done on the box where this is not a problem. In this scenario, SGen.exe actually exists and is right where it's supposed to be, but MSBuild still is having issues with finding it for some reason! Background: We have a NAnt script that automates our builds. In this scenario, NAnt is calling MSBuild and MSBuild is generating the error claiming to be unable to find SGen. The project is .NET 3.5-based. I have my primary dev environment (64-bit Vista Ultimate) where the script works perfectly and I am attempting to duplicate it in a VM (64-bit Win 7 Ultimate). I THINK I have everything to the point where I should be good-to-go but this fails on the Win7 box (works perfectly on the Vista box). I have done some comparisons between the two boxes and they both look identical in this regard, but it still fails. For example, the HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\.NETFramework's sdkInstallRootv2.0 value is set to C:\Program Files\Microsoft.NET\SDK\v2.0 64bit\ on both machines. In both machines, SGen.exe is in that path's bin subdirectory. NAnt Script: <target name="report-installer" depends="fail-if-environment-not-set"> <exec program="MSBuild.exe" basedir="${framework35.directory}"> <arg value="${tools.directory.current}\ReportInstaller\ReportInstaller.sln" /> <arg value="/p:Configuration=${buildconfiguration.current}" /> </exec> </target> The error message I get is this: report-installer: [exec] Microsoft (R) Build Engine Version 3.5.30729.4926 [exec] [Microsoft .NET Framework, Version 2.0.50727.4927] [exec] Copyright (C) Microsoft Corporation 2007. All rights reserved. [exec] [exec] Build started 4/8/2010 11:28:23 AM. [exec] Project "C:\Projects\Production\Tools\ReportInstaller\ReportInstaller.sln" on node 0 (default targets). [exec] Building solution configuration "Release|Any CPU". [exec] Project "C:\Projects\Production\Tools\ReportInstaller\ReportInstaller.sln" (1) is building "C:\Projects\Production\Tools\ReportInstaller\ReportInstaller.csproj" (2) on node 0 (default targets). [exec] Could not locate the .NET Framework SDK. The task is looking for the path to the .NET Framework SDK at the location specified in the SDKInstallRootv2.0 value of the registry key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\.NETFramework. You may be able to solve the problem by doing one of the following: 1.) Install the .NET Framework SDK. 2.) Manually set the above registry key to the correct location. [exec] CoreCompile: [exec] Skipping target "CoreCompile" because all output files are up-to-date with respect to the input files. [exec] C:\Windows\Microsoft.NET\Framework\v2.0.50727\Microsoft.Common.targets(1902,9): error MSB3091: Task failed because "sgen.exe" was not found, or the .NET Framework SDK v2.0 is not installed. The task is looking for "sgen.exe" in the "bin" subdirectory beneath the location specified in the SDKInstallRootv2.0 value of the registry key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\.NETFramework. You may be able to solve the problem by doing one of the following: 1.) Install the .NET Framework SDK v2.0. 2.) Manually set the above registry key to the correct location. 3.) Pass the correct location into the "ToolPath" parameter of the task. [exec] Done Building Project "C:\Projects\Production\Tools\ReportInstaller\ReportInstaller.csproj" (default targets) -- FAILED. [exec] Done Building Project "C:\Projects\Production\Tools\ReportInstaller\ReportInstaller.sln" (default targets) -- FAILED. [exec] [exec] Build FAILED. [exec] [exec] "C:\Projects\Production\Tools\ReportInstaller\ReportInstaller.sln" (default target) (1) -> [exec] "C:\Projects\Production\Tools\ReportInstaller\ReportInstaller.csproj" (default target) (2) -> [exec] (GenerateSerializationAssemblies target) -> [exec] C:\Windows\Microsoft.NET\Framework\v2.0.50727\Microsoft.Common.targets(1902,9): error MSB3091: Task failed because "sgen.exe" was not found, or the .NET Framework SDK v2.0 is not installed. The task is looking for "sgen.exe" in the "bin" subdirectory beneath the location specified in the SDKInstallRootv2.0 value of the registry key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\.NETFramework. You may be able to solve the problem by doing one of the following: 1.) Install the .NET Framework SDK v2.0. 2.) Manually set the above registry key to the correct location. 3.) Pass the correct location into the "ToolPath" parameter of the task. [exec] [exec] 0 Warning(s) [exec] 1 Error(s) [exec] [exec] Time Elapsed 00:00:00.24 [call] C:\Projects\Production\Source\reports.build(15,4): [call] External Program Failed: C:\Windows\Microsoft.NET\Framework\v3.5\MSBuild.exe (return code was 1) What am I doing wrong here that is causing MSBuild to STILL be unable to find SGen?

    Read the article

  • Unique Keys not recognized by Entity Framework

    - by David Pfeffer
    I have two tables, Reports and Visualizations. Reports has a field, VisualizationID, which points to Visualization's field of the same name via a foreign key. It also has a unique key declared on the field. VisualizationID is not nullable. This means the relationship has to be 0..1 to 1, because every Reports record must have a unique, not null Visualizations record associated with it. The Entity Framework doesn't see it this way. I'm getting the following error: Error 113: Multiplicity is not valid in Role 'Report' in relationship 'FK_Reports_Visualizations'. Because the Dependent Role properties are not the key properties, the upper bound of the multiplicity of the Dependent Role must be *. What's the problem here? How can I make the EF recognize the proper relationship multiplicity?

    Read the article

  • Cognos 8.3 - date prompt macro problem

    - by Jacob
    In Report Studio 8.3, I've got this raw SQL query running against a MySQL 5.1 data source: SELECT enc.encounterID, enc.date FROM enc WHERE enc.date between #prompt('textPromptStartDate')# AND #prompt('textPromptEndDate', 'date')# This produces text prompts for the user. If the user enters dates into these prompts in the format of 'YYYY-MM-DD', e.g. '2010-01-15', the query works fine. But I want to replace the text prompts with proper Date prompts. When I try replacing the above prompts with #prompt('datePromptStartDate', 'date') AND #prompt('datePromptEndDate', 'date')# the query runs (no errors are generated), but I get an empty result set. I have a feeling I need to adjust the date format that the date prompt macro returns, but I'm stuck after many hours of experimentation as to how to debug this.

    Read the article

  • WebBrowser control HTMLDocument automate selecting option drop-down

    - by CWinKY
    I'm trying to automate in a WinForm using a WebBrowser control to navigate and pull report info from a website. You can enter values in textboxes and invoke the click events for buttons and links, but I have not figured out how select a option drop-down .... in a automated way. Anybody recommend how to select a item from a drop-down, given this html example: <SELECT id="term_id" size="1" name="p_term_in"><option value="">Select Another Term<option value="201050">Summer 2010<option value="201010">Spring 2010<option value="200980">Fall 2009</SELECT> For others that can learn from entering values to textboxes and invoking click events here's how you do it: webBrowser1.Document.GetElementById("<HTML ELEMENT NAME>").SetAttribute("value", "THE NAME"); Invoke button or hyperlink click: webBrowser1.Document.GetElementById("<BUTTON>").InvokeMember("click"); So I've solved entering values and invoking click, but I have not solved selecting a drop-down value.

    Read the article

  • How to convert SSRS 2008 Server reports to SSRS 2008 Client Reports

    - by Nasser Hajloo
    I have a large SSRS 2008 Server Report Project (more than 200 reports). Currently my companystrategy has been changed and we want to convert these server reports to client reports. All of the Server reports uses Storeprocedures (or in some cases from the SQl Functions) All of them work properly andthere is no problem Beause of project scale it is not a good idea to create all of server reports in client again. SO I want to check How to convert SSRS 2008 Server reports to SSRS 2008 Client Reports? RDL to RDLC. Note : I knowthat Client reports use Dataset And I have to create Dataset. I'm also looking for a way to generate these dataset too.but for now I'm just looking for a way to convert RDL files to RDLC files. If there are anyApplication which can convert RDL XML to RDLC XML let me know. Any help appriciate.

    Read the article

  • How to eager load in WCF Ria Services/Linq2SQLDomainModel

    - by Aggelos Mpimpoudis
    I have a databound grid at my view (XAML) and the Itemsource points to a ReportsCollection. The Reports entity has three primitives and some complex types. These three are shown as expected at datagrid. Additionally the Reports entity has a property of type Store. When loading Reports via GetReports domain method, I quickly figure out that only primitives are returned and not the whole graph of some depth. So, as I wanted to load the Store property too, I made this alteration at my domain service: public IQueryable<Report> GetReports() { return this.ObjectContext.Reports.Include("Store"); } From what I see at the immediate window, store is loaded as expected, but when returned to client is still pruned. How can this be fixed? Thank you!