Search Results

Search found 7517 results on 301 pages for 'fast debugger'.

Page 267/301 | < Previous Page | 263 264 265 266 267 268 269 270 271 272 273 274  | Next Page >

  • Wireless traffic stops when downloading large files at high speed: packets lost (Linksys WRT120N router)

    - by Torious
    The problem Note: First I'd like to understand WHY this is happening. Ofcourse, a solution would be nice too. :) When downloading a large file over HTTP at high-speeds, my wireless traffic basically stops: I can't open webpages and the download itself pauses. It pauses pretty much immediately after starting it; sometimes at 800 KB, sometimes at a few MB. After some time, the download (and other traffic) resumes, but the problem keeps reoccurring during the same download. The problem does not occur when using a wired connection through the same router (Linskys WRT120N). Also note that the connection is not dropped when this happens. It's just that the traffic stops and I can't browse to web pages, etc. (SYN packets are sent but nothing is received, etc.) Inspection with Wireshark shows that the following happens: Server sends data packets which are acknowledged by client Server sends a packet, but SEQ indicates some packets were lost (6 packets in one occurrence). Server sends a few more packets and client acknowledges these using "selective acknowledgement" Server stops sending data for a while (since the lost packets were not acknowledged or the router stops forwarding them?) Eventually, server does a "retransmission" and traffic resumes as normal. This all seems normal behavior to me when packet loss occurs. It's the consistent packet loss throughout a large, high-speed download that puzzles me. What might cause this? My own idea is the following: My internet is pretty fast (100 mbps), so when starting a large-file download, the router buffers the incoming data (since wireless introduces some slight delay / lower speed, in part due to other networks), but the buffer overflows and the router drops packets to regulate traffic (and because it has no choice). But how could that happen? Doesn't the TCP window size limit the amount of data that can go unacknowledged? So how can the router's buffer overflow if there can only be like 64 KB waiting to be acknowledged? Note: I've disabled TCP window scaling and dynamic window size through netsh options, in an attempt to fix this, but it doesn't seem to matter. Also, Wireshark shows a pattern of the server sending 2 packets (of 1514 bytes) and the client sending an ACK, so does that rule out a possible buffer overflow? And a few more subsequent packets are received... I'm at a loss here. Thanks for any insights. Things that are (probably) NOT the cause / I have experimented with The browser Various TCP options in Windows 7 (netsh etc.) Router settings such as MTU, beacon interval, UPnP, ...

    Read the article

  • How to install missing Sound Drivers in Ubuntu?

    - by Sakamoto Kazuma
    I seem to be missing drivers for my Gateway laptop MA7. I have looked in System-Admin-Hardware Drivers, but it does not show up in there.There are also no devices listed in Sound-Hardware. I'm guessing at this point that I don't have the driver installed. However, I get the following output: admin@machine001:~$ cat /proc/asound/cards 0 [Intel ]: HDA-Intel - HDA Intel HDA Intel at 0xd8240000 irq 22 admin@machine001:~$ And my lspci shows: 00:00.0 Host bridge: Intel Corporation Mobile 945GM/PM/GMS, 943/940GML and 945GT Express Memory Controller Hub (rev 03) 00:02.0 VGA compatible controller: Intel Corporation Mobile 945GM/GMS, 943/940GML Express Integrated Graphics Controller (rev 03) 00:02.1 Display controller: Intel Corporation Mobile 945GM/GMS/GME, 943/940GML Express Integrated Graphics Controller (rev 03) 00:1b.0 Audio device: Intel Corporation 82801G (ICH7 Family) High Definition Audio Controller (rev 02) 00:1c.0 PCI bridge: Intel Corporation 82801G (ICH7 Family) PCI Express Port 1 (rev 02) 00:1c.1 PCI bridge: Intel Corporation 82801G (ICH7 Family) PCI Express Port 2 (rev 02) 00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 02) 00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 02) 00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 02) 00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 02) 00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 02) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev e2) 00:1f.0 ISA bridge: Intel Corporation 82801GBM (ICH7-M) LPC Interface Bridge (rev 02) 00:1f.1 IDE interface: Intel Corporation 82801G (ICH7 Family) IDE Controller (rev 02) 00:1f.2 SATA controller: Intel Corporation 82801GBM/GHM (ICH7 Family) SATA AHCI Controller (rev 02) 00:1f.3 SMBus: Intel Corporation 82801G (ICH7 Family) SMBus Controller (rev 02) 02:00.0 Ethernet controller: Marvell Technology Group Ltd. 88E8038 PCI-E Fast Ethernet Controller (rev 14) 03:00.0 Network controller: Intel Corporation PRO/Wireless 3945ABG [Golan] Network Connection (rev 02) 04:09.0 CardBus bridge: Texas Instruments PCIxx12 Cardbus Controller 04:09.1 FireWire (IEEE 1394): Texas Instruments PCIxx12 OHCI Compliant IEEE 1394 Host Controller 04:09.2 Mass storage controller: Texas Instruments 5-in-1 Multimedia Card Reader (SD/MMC/MS/MS PRO/xD) I have also checked alsamixer, and nothing is muted. No headphones plugged into headphone jack either. So the question now is, how do I get sound to work on my laptop? It doesn't work for any application.

    Read the article

  • Sendmail Tuning For Batch Mail Jobs

    - by Kyle Brandt
    I have a webservers that send out emails to a sendmail relay server as a batch job. The emails need to be accepted by the relay sendmail server as fast as possible, however, they do not need to go out (be relayed) very quickly. I am seeing a couple timeouts once and a while from the webserver trying to connect to the relay server. The load currently is about 30 emails a second for a couple minutes. There are quite a few tuning options for sendmail in the sendmail tuning guide. What I am focusing on now is the Delivery Mode: Delivery Mode There are a number of delivery modes that sendmail can operate in, set by the DeliveryMode ( d) configuration option. These modes specify how quickly mail will be delivered. Legal modes are: i deliver interactively (synchronously) b deliver in background (asynchronously) q queue only (don't deliver) d defer delivery attempts (don't deliver) There are tradeoffs. Mode i gives the sender the quickest feedback, but may slow down some mailers and is hardly ever necessary. Mode b delivers promptly but can cause large numbers of processes if you have a mailer that takes a long time to deliver a message. Mode q minimizes the load on your machine, but means that delivery may be delayed for up to the queue interval. Mode d is identical to mode q except that it also prevents lookups in maps including the -D flag from working during the initial queue phase; it is intended for ``dial on demand'' sites where DNS lookups might cost real money. Some simple error messages (e.g., host unknown during the SMTP protocol) will be delayed using this mode. Mode b is the usual default. If you run in mode q (queue only), d (defer), or b (deliver in background) sendmail will not expand aliases and follow .forward files upon initial receipt of the mail. This speeds up the response to RCPT commands. Mode i should not be used by the SMTP server. I currently have the CentOS default modes: Sendmail.cf: DeliveryMode=background Submit.cf: DeliveryMode=i Is sendmail.cf/mc for outgoing email from relay (to the intertubes) and sumbit.cf/mc for incoming eamil (from my webservers). Would it make sense to change the outgoing delivery mode to queue? If I did, what would the outbound email flow behave like? If this is the right thing to do, can anyone show me example mc configurations for this change? If it isn't, what recommendations are there for these constraints?

    Read the article

  • hyperv machine guest loads slow

    - by Dani Avni
    this is by far one of the strangest things I have seen. I have a win 2008R2 cluster with a CSV. the CSV itself is on an iSCSI storage (hitachi HUS 110) basic config of the two hosts in the cluster is Dell R610 Win 2008 R2 with all patches 64GB 1 NIC for host access 2 NICs for guest access 2 NICs for iSCSI these machine work great and I can load a 2008R2 test guest machine on them in less than 90 seconds after the above config is running for over a year, I now need to add a new host. now the host is Dell R620 (Still intel but different CPU) Win 2008 R2 with all patches 64GB 1 NIC for host access 2 NICs for guest access 2 NICs for iSCSI I added this new host to the domain and to the cluster, I gave it access to the CSV and I tried loading the same guest machine that loads in 90 seconds in the other hosts. the machine loads in about 6 minutes. no matter how many times I try this the old hosts load the machine in about 90 seconds and this new host in around 6 minutes to eliminate any problems with the iSCSI connection, I added a new LUN and directly accessed it from the new host and I was working at around 300MB/s so no problem there. I also tested the connection between the other hosts and the new one and network is working fine there too. to eliminate problems in HyperV, I copied the machine to the local disk of the new host and it loaded in less than 20 seconds. now is the point were things get a lot stranger: in my tests I tried installing a fresh windows guest machine to the CSV from the new host. I noticed that while the fresh windows was installing, my test guest was loading in less than 90 seconds even on the new host (I repeated this a few times). If I paused the fresh install guest and tried loading the test guest again it loaded in 6 minutes. and again after I resumed the guest installation the test guest loaded fast. after the fresh windows was also loaded, I ran tests loading the fresh window and my test machine. each one of them loaded in about 5 minutes when I tried loading them separately. however when I started both of them in the same time they both loaded in around 2.5 minutes it seems that the iSCSI disk access is only working if it is under some load (although I never got to above 10% utilization according to the task manager) does anyone have any idea what could be the problem?

    Read the article

  • Linux per-process resource limits - a deep Red Hat Mystery

    - by BobBanana
    I have my own multithreaded C program which scales in speed smoothly with the number of CPU cores.. I can run it with 1, 2, 3, etc threads and get linear speedup.. up to about 5.5x speed on a 6-core CPU on a Ubuntu Linux box. I had an opportunity to run the program on a very high end Sunfire x4450 with 4 quad-core Xeon processors, running Red Hat Enterprise Linux. I was eagerly anticipating seeing how fast the 16 cores could run my program with 16 threads.. But it runs at the same speed as just TWO threads! Much hair-pulling and debugging later, I see that my program really is creating all the threads, they really are running simultaneously, but the threads themselves are slower than they should be. 2 threads runs about 1.7x faster than 1, but 3, 4, 8, 10, 16 threads all run at just net 1.9x! I can see all the threads are running (not stalled or sleeping), they're just slow. To check that the HARDWARE wasn't at fault, I ran SIXTEEN copies of my program independently, simultaneously. They all ran at full speed. There really are 16 cores and they really do run at full speed and there really is enough RAM (in fact this machine has 64GB, and I only use 1GB per process). So, my question is if there's some OPERATING SYSTEM explanation, perhaps some per-process resource limit which automatically scales back thread scheduling to keep one process from hogging the machine. Clues are: My program does not access the disk or network. It's CPU limited. Its speed scales linearly on a single CPU box in Ubuntu Linux with a hexacore i7 for 1-6 threads. 6 threads is effectively 6x speedup. My program never runs faster than 2x speedup on this 16 core Sunfire Xeon box, for any number of threads from 2-16. Running 16 copies of my program single threaded runs perfectly, all 16 running at once at full speed. top shows 1600% of CPUs allocated. /proc/cpuinfo shows all 16 cores running at full 2.9GHz speed (not low frequency idle speed of 1.6GHz) There's 48GB of RAM free, it is not swapping. What's happening? Is there some process CPU limit policy? How could I measure it if so? What else could explain this behavior? Thanks for your ideas to solve this, the Great Xeon Slowdown Mystery of 2010!

    Read the article

  • WSUS is not using Akamai CDN for syncronisation source

    - by Geekman
    I've just installed a WSUS onto our network, and I'm currently doing the initial sync. I've found that WSUS does not seem to be talking to an Akamai cache, but rather with MS directly. This is contrary to what I've always thought regarding Windows Update traffic. Tcpdump of our WSUS server doing initial sync... As you can see it's speaking with 65.55.194.221. For me to speak to this IP, I have to go over international transit links. Which is of course not ideal. 8:42:31.279757 IP 65.55.194.221.https > XXXX.XXXX.XXXX.XXXX.50888: Flags [.], seq 4379374:4380834, ack 289611, win 256, length 1460 18:42:31.279759 IP 65.55.194.221.https > XXXX.XXXX.XXXX.XXXX.50888: Flags [.], seq 4380834:4382294, ack 289611, win 256, length 1460 18:42:31.279762 IP 65.55.194.221.https > XXXX.XXXX.XXXX.XXXX.50888: Flags [.], seq 4382294:4383754, ack 289611, win 256, length 1460 18:42:31.279764 IP 65.55.194.221.https > XXXX.XXXX.XXXX.XXXX.50888: Flags [P.], seq 4383754:4384144, ack 289611, win 256, length 390 18:42:31.279793 IP XXXX.XXXX.XXXX.XXXX.50888 > 65.55.194.221.https: Flags [.], ack 4369154, win 23884, length 0 18:42:31.279888 IP XXXX.XXXX.XXXX.XXXX.50888 > 65.55.194.221.https: Flags [.], ack 4377914, win 23884, length 0 18:42:31.280015 IP XXXX.XXXX.XXXX.XXXX.50888 > 65.55.194.221.https: Flags [.], ack 4384144, win 23884, length 0 And yet, if I ping download.windowsupdate.com it seems to resolve to a local (national) Akamai node, just fine: root@some-node:~# ping download.windowsupdate.com PING a26.ms.akamai.net (210.9.88.48) 56(84) bytes of data. 64 bytes from a210-9-88-48.deploy.akamaitechnologies.com (210.9.88.48): icmp_req=1 ttl=59 time=1.02 ms 64 bytes from a210-9-88-48.deploy.akamaitechnologies.com (210.9.88.48): icmp_req=2 ttl=59 time=1.10 ms Why is this? And how can I change that (if possible)? I know that I can manually specify a WSUS source to sync with instead of pick the default MS Update like I currently have... But it seems like I shouldn't have to do this. NOTE: I've haven't confirmed if a WUA speaks with Akamai, just looking at WSUS as all WUAs will use our internal WSUS from now on. We'll be looking to join an IX shortly with the hopes of peering with an Akamai cache and have very fast access to Windows Updates. Before I let this drive my motivations for an IX at all I want to first confirm it's actually possible for WSUS to speak with an Akamai cache. I know this is somewhat networking related, but I feel like it has more to do with WSUS than anything, so someone who knows WSUS better than me will likely be able to figure this out.

    Read the article

  • Innodb Queries Slow

    - by user105196
    I have redHat 5.3 (Tikanga) with Mysql 5.0.86 configued with RIAD 10 HW, I run an application inquiries from Mysql/InnoDB and MyIsam tables, the queries are super fast,but some quires on Innodb tables sometime slow down and took more than 1-3 seconds to run and these queries are simple and optimized, this problem occurred just on innodb tables in different time with random queries. Why is this happening only to Innodb tables? the below is the Innodb status and some Mysql variables: show innodb status\G ************* 1. row ************* Status: 120325 10:54:08 INNODB MONITOR OUTPUT Per second averages calculated from the last 19 seconds SEMAPHORES OS WAIT ARRAY INFO: reservation count 22943, signal count 22947 Mutex spin waits 0, rounds 561745, OS waits 7664 RW-shared spins 24427, OS waits 12201; RW-excl spins 1461, OS waits 1277 TRANSACTIONS Trx id counter 0 119069326 Purge done for trx's n:o < 0 119069326 undo n:o < 0 0 History list length 41 Total number of lock structs in row lock hash table 0 LIST OF TRANSACTIONS FOR EACH SESSION: ---TRANSACTION 0 0, not started, process no 29093, OS thread id 1166043456 MySQL thread id 703985, query id 5807220 localhost root show innodb status FILE I/O I/O thread 0 state: waiting for i/o request (insert buffer thread) I/O thread 1 state: waiting for i/o request (log thread) I/O thread 2 state: waiting for i/o request (read thread) I/O thread 3 state: waiting for i/o request (write thread) Pending normal aio reads: 0, aio writes: 0, ibuf aio reads: 0, log i/o's: 0, sync i/o's: 0 Pending flushes (fsync) log: 0; buffer pool: 0 132777 OS file reads, 689086 OS file writes, 252010 OS fsyncs 0.00 reads/s, 0 avg bytes/read, 0.00 writes/s, 0.00 fsyncs/s INSERT BUFFER AND ADAPTIVE HASH INDEX Ibuf: size 1, free list len 366, seg size 368, 62237 inserts, 62237 merged recs, 52881 merges Hash table size 8850487, used cells 3698960, node heap has 7061 buffer(s) 0.00 hash searches/s, 0.00 non-hash searches/s LOG Log sequence number 15 3415398745 Log flushed up to 15 3415398745 Last checkpoint at 15 3415398745 0 pending log writes, 0 pending chkp writes 218214 log i/o's done, 0.00 log i/o's/second BUFFER POOL AND MEMORY Total memory allocated 4798817080; in additional pool allocated 12342784 Buffer pool size 262144 Free buffers 101603 Database pages 153480 Modified db pages 0 Pending reads 0 Pending writes: LRU 0, flush list 0, single page 0 Pages read 151954, created 1526, written 494505 0.00 reads/s, 0.00 creates/s, 0.00 writes/s No buffer pool page gets since the last printout ROW OPERATIONS 0 queries inside InnoDB, 0 queries in queue 1 read views open inside InnoDB Main thread process no. 29093, id 1162049856, state: waiting for server activity Number of rows inserted 77675, updated 85439, deleted 0, read 14377072495 0.00 inserts/s, 0.00 updates/s, 0.00 deletes/s, 0.00 reads/s END OF INNODB MONITOR OUTPUT 1 row in set, 1 warning (0.02 sec) read_buffer_size = 128M sort_buffer_size = 256M tmp_table_size = 1024M innodb_additional_mem_pool_size = 20M innodb_log_file_size=10M innodb_lock_wait_timeout=100 innodb_buffer_pool_size=4G join_buffer_size = 128M key_buffer_size = 1G can any one help me ?

    Read the article

  • Proxy Error 502 "Reason: Error reading from remote server" with Apache 2.2.3 (Debian) mod_proxy and Jetty 6.1.18

    - by Martin
    Apache is receiving requests at port :80 and proxying them to Jetty at port :8080 The proxy server received an invalid response from an upstream server The proxy server could not handle the request GET /. My dilemma: Everything works fine normally (fast requests, few seconds or few tens of seconds long requests are processed ok). Problems occur when request processing takes long (few minutes?). If I issue request instead directly to Jetty at port :8080 the request is processed OK. So problem is likely to sit somewhere between Apache and Jetty where I am using mod_proxy. How to solve this? I have already tried some "tricks" related to KeepAlive settings, without luck. Here is my current configuration, any suggestions? #keepalive Off ## I have tried this, does not help #SetEnv force-proxy-request-1.0 1 ## I have tried this, does not help #SetEnv proxy-nokeepalive 1 ## I have tried this, does not help #SetEnv proxy-initial-not-pooled 1 ## I have tried this, does not help KeepAlive 20 ## I have tried this, does not help KeepAliveTimeout 600 ## I have tried this, does not help ProxyTimeout 600 ## I have tried this, does not help NameVirtualHost *:80 <VirtualHost _default_:80> ServerAdmin [email protected] ServerName www.mydomain.fi ServerAlias mydomain.fi mydomain.com mydomain www.mydomain.com ProxyRequests On ProxyVia On <Proxy *> Order deny,allow Allow from all </Proxy> ProxyRequests Off ProxyPass / http://www.mydomain.fi:8080/ retry=1 acquire=3000 timeout=600 ProxyPassReverse / http://www.mydomain.fi:8080/ RewriteEngine On RewriteCond %{SERVER_NAME} !^www\.mydomain\.fi RewriteRule /(.*) http://www.mydomain.fi/$1 [redirect=301L] ErrorLog /var/log/apache2/error.log # Possible values include: debug, info, notice, warn, error, crit, # alert, emerg. LogLevel warn CustomLog /var/log/apache2/access.log combined ServerSignature On </VirtualHost> Here is also the debug log from a failing request: 74.125.43.99 - - [29/Sep/2010:20:15:40 +0300] "GET /?wicket:bookmarkablePage=newWindow:com.mydomain.view.application.reports.SaveReportPage HTTP/1.1" 502 355 "https://www.mydomain.fi/?wicket:interface=:0:2:::" "Mozilla/5.0 (Windows; U; Windows NT 6.1; fi; rv:1.9.2.10) Gecko/20100914 Firefox/3.6.10" [Wed Sep 29 20:20:40 2010] [error] [client 74.125.43.99] proxy: error reading status line from remote server www.mydomain.fi, referer: https://www.mydomain.fi/?wicket:interface=:0:2::: [Wed Sep 29 20:20:40 2010] [error] [client 74.125.43.99] proxy: Error reading from remote server returned by /, referer: https://www.mydomain.fi/?wicket:interface=:0:2:::

    Read the article

  • How to Configure Source NAT (Private IP => Public IP Outbound)

    - by DavidScherer
    I'm running VMWare ESXi Free and have Zentyal SBS 3.2 running as a Gateway. I have 5 Public IPS (CIDR/29, let's call them 69.1.1.1 - 69.1.1.5) and currently Zentyal is bound to 69.1.1.1 as the Gateway, with the other 4 Public IPs set as Virtual Interfaces in Zentyal (wan2-wan5) I have machines sitting on the Private Network (10.34.251.x) that, when going Outbound (to Google for instance) should be seen by the Internet as an IP other than the Gateway (69.1.1.1), this is because our machines need to be able to communicate with 3rd party APIs that expect these requests to come from a specific IP. From what I could find, SNAT (Source NAT) in Zentyal is used to achieve this, but I'm not sure how to configure it and cannot find a specific piece of Documentation for it at Zentyal. I've tried setting this up a couple different ways, with no results and at this point I have no idea if I'm going about this completely wrong, or my lack of experience with networking and the associated terminology is preventing me from placing the correct values in the correct fields. I get the following form to set up "SNAT" rules in Zentyal: Perhaps someone can offer some guidance and definitions for the fields above? SNAT Address Is this the Public IP I want to masquerade? Outgoing Interface Should this by my External NIC (one connected to Public 'Net), or is it the "Private" interface? It sounds as though this should be the External interface as I want the traffic from the internal network sent Out over this Interface (using a different IP than normal, anyway) Source Is the the Source on the internal network (one of the private IPs?), a public IP I want to masquerade as, or something else entirely? Destination Is this a place on the Internet (eg, "Only do this for the Site Google.com"/IP) or am I allowing myself to become confused again? Service I'm assuming this allows me to restrict which services this rule will apply to, but is it for a service on the internal network or a service being accessed on the external network? If I can offer any further details or information to make what I'm trying to do more clear, I will happily do so. Honestly any kind of help here would be very appreciated. I'm not a NetOps or anything even close, I spend most of my day writing code and my entire "team" at this company consists of "me, myself, and I" so while I try to broaden my KB at every possible opportunity, I can only learn so much, so fast and I feel like with networking especially there's just so much, coupled with a learning curve for each solution that likes to (from my limited perspective) use slightly different terminology that what I'm used to (and I don't exactly have the necessary experience to cross reference this stuff with the stuff I already know in context).

    Read the article

  • Ubuntu hardware wireless switch has no effect after suspend and 13.10 upgrade

    - by blaineh
    I'm posting this on SU after it stalled on askubuntu. I hope someone here can help! If you'd prefer to answer on AU itself, here's the link: http://askubuntu.com/questions/365177/hardware-wireless-switch-has-no-effect-after-suspend-and-13-10-upgrade Wireless works fine after a reboot, but after a suspend the hardware switch (for my laptop this is f12) has no effect on the wireless, it is just permanently off, and shows that it is with a red LED. My rfkill list all reads: 0: phy0: Wireless LAN Soft blocked: no Hard blocked: yes 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: yes Any combination with rfkill <un>block wifi doesn't work, although one time first blocking then unblocking actually turned it on again. sudo lshw -C network reads: *-network DISABLED description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Qualcomm Atheros physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 01 serial: 78:e4:00:65:2e:3f width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.11.0-12-generic firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:17 memory:90100000-9010ffff *-network DISABLED description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 02 serial: c8:0a:a9:89:b4:30 size: 10Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:42 ioport:2000(size=256) memory:90010000-90010fff memory:90000000-9000ffff memory:90020000-9002ffff Also, adding a /etc/pm/sleep.d/brcm.sh file as recommended here simply prevents the laptop from suspending at all, which of course is no good. This question has an answer urging to install the original driver, but it wasn't an "accepted answer" so I'd rather not take a chance on it. Also I'll admit I'm a bit lost on that and would like help doing so with the specific information I've given. I would be happy to provide more information, so long as you're willing to help me find it for you! This is a very annoying bug. I have a Compaq Presario CQ62. Edit. Output of lspci | grep Network: 02:00.0 Network controller: Qualcomm Atheros AR9285 Wireless Network Adapter (PCI-Express) (rev 01) Edit. This morning, I had had the laptop suspended all night, and then when I tried to awake it, it simply wouldn't. It would try, and then it would sleep again (I guess it felt a little bit like me! </badjoke>). Is it possible these problems are related? Edit. I don't have enough reputation on SU proper to post links to pastebins and other questions I've tried, so I'm putting them in comments, and of course they're available in the original question.

    Read the article

  • how to setup kismet.conf on Ubuntu

    - by Registered User
    I installed Kismet on my Ubuntu 10.04 machine as apt-get install kismet every thing seems to work fine. but when I launch it I see following error kismet Launching kismet_server: //usr/bin/kismet_server Suid priv-dropping disabled. This may not be secure. No specific sources given to be enabled, all will be enabled. Non-RFMon VAPs will be destroyed on multi-vap interfaces (ie, madwifi-ng) Enabling channel hopping. Enabling channel splitting. NOTICE: Disabling channel hopping, no enabled sources are able to change channel. Source 0 (addme): Opening none source interface none... FATAL: Please configure at least one packet source. Kismet will not function if no packet sources are defined in kismet.conf or on the command line. Please read the README for more information about configuring Kismet. Kismet exiting. Done. I followed this guide http://www.ubuntugeek.com/kismet-an-802-11-wireless-network-detector-sniffer-and-intrusion-detection-system.html#more-1776 how ever in kismet.conf I am not clear with following line source=none,none,addme as to what should I change this to. lspci -vnn shows 0c:00.0 Network controller [0280]: Broadcom Corporation BCM4312 802.11b/g [14e4:4315] (rev 01) Subsystem: Dell Device [1028:000c] Flags: bus master, fast devsel, latency 0, IRQ 17 Memory at f69fc000 (64-bit, non-prefetchable) [size=16K] Capabilities: [40] Power Management version 3 Capabilities: [58] Vendor Specific Information <?> Capabilities: [e8] Message Signalled Interrupts: Mask- 64bit+ Queue=0/0 Enable- Capabilities: [d0] Express Endpoint, MSI 00 Capabilities: [100] Advanced Error Reporting <?> Capabilities: [13c] Virtual Channel <?> Capabilities: [160] Device Serial Number Capabilities: [16c] Power Budgeting <?> Kernel driver in use: wl Kernel modules: wl, ssb and iwconfig shows lo no wireless extensions. eth0 no wireless extensions. eth1 IEEE 802.11bg ESSID:"WIKUCD" Mode:Managed Frequency:2.462 GHz Access Point: <00:43:92:21:H5:09> Bit Rate=11 Mb/s Tx-Power:24 dBm Retry min limit:7 RTS thr:off Fragment thr:off Encryption key:off Power Managementmode:All packets received Link Quality=1/5 Signal level=-81 dBm Noise level=-90 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:169 Invalid misc:0 Missed beacon:0 So what should I be putting in place of source=none,none,addme with output I mentioned above ?

    Read the article

  • XCP Project Kronos syslog error: "irq ... : nobody cared" on Dom0 host

    - by Vlad Fedin
    One of our production clusters driven by XCP suddenly went uresponsive. After restart and some investigation we found such logs in dom0 machine syslog: Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659040] irq 339: nobody cared (try booting with the "irqpoll" option) Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659058] Pid: 0, comm: swapper/3 Tainted: G C O 3.2.0-24-generic #37-Ubuntu Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659060] Call Trace: Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659062] <IRQ> [<ffffffff810db37d>] __report_bad_irq+0x3d/0xe0 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659071] [<ffffffff810db605>] note_interrupt+0x135/0x190 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659074] [<ffffffff810d8e69>] handle_irq_event_percpu+0xa9/0x220 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659078] [<ffffffff8130ff3b>] ? radix_tree_lookup+0xb/0x10 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659081] [<ffffffff810d9031>] handle_irq_event+0x51/0x80 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659084] [<ffffffff810dc187>] handle_edge_irq+0x87/0x140 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659089] [<ffffffff813a8829>] __xen_evtchn_do_upcall+0x199/0x250 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659092] [<ffffffff813aa96f>] xen_evtchn_do_upcall+0x2f/0x50 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659096] [<ffffffff81666d3e>] xen_do_hypervisor_callback+0x1e/0x30 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659097] <EOI> [<ffffffff810013aa>] ? hypercall_page+0x3aa/0x1000 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659104] [<ffffffff810013aa>] ? hypercall_page+0x3aa/0x1000 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659107] [<ffffffff8100a1d0>] ? xen_safe_halt+0x10/0x20 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659110] [<fff IRQ 339 in cat /proc/interrupts: 339: ... xen-pirq-msi-x eth0 where eth0 is hardware NIC. While host machine seems to hang, guest machines continue to work, so our tiny internal monitoring on one of the virtual hosts logged something like that: [2012-10-26 20:31:51] [OK......] 200 OK : 113159149 ns [2012-10-26 20:32:40] [DISASTER] 500 Can't connect to [hostname]:80 (No route to host) : 47763284432 ns ... [2012-10-26 20:34:40] [DISASTER] 500 Can't connect to [hostname]:80 (No route to host) : 46894835070 ns [2012-10-26 20:34:57] [DISASTER] 500 Can't connect to [hostname]:80 (Bad hostname) : 16821741955 ns ... [2012-10-26 20:38:18] [DISASTER] 500 Can't connect to [hostname]:80 (Bad hostname) : 20103298289 ns [2012-10-26 20:38:37] [DISASTER] 500 Can't connect to [hostname]:80 (Bad hostname) : 17895754943 ns Host and guest OS: Ubuntu 12.04 LTS, 05:00.0 Ethernet controller: Intel Corporation 82574L Gigabit Network Connection Subsystem: ASUSTeK Computer Inc. Device 8369 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx+ Latency: 0, Cache Line Size: 64 bytes Interrupt: pin A routed to IRQ 17 Region 0: Memory at fe500000 (32-bit, non-prefetchable) [size=128K] Region 2: I/O ports at e000 [size=32] Region 3: Memory at fe520000 (32-bit, non-prefetchable) [size=16K] Capabilities: <access denied> Kernel driver in use: e1000e Kernel modules: e1000e Any hints how to debug this?

    Read the article

  • Creating a network link between 2 very close buildings

    - by Daniel Johnson
    I have a charity who have two adjacent medium sized modern detached houses (in the UK): the buildings stand next to each other and are less than 5 metres apart. They have DSL connected to a single computer in one of the buildings. They want to add a network with wireless, and want it to work across both buildings. Being a charity they need to keep costs down. The network would be used for sharing Word documents, e-mail, browsing and skyping. My initial thoughts were to connect the buildings with fibre. So: Option 1 Use fibre between the buildings. Sufficient cable and two TP-LINK MC100CM Fast Ethernet Media Converters. Cost ~£80.00. But there is the extra cost and hassle of running the cable down and up the external walls, lifting and relaying paving, and burying underground. Never having fitted fibre I'm also a little worried about going up the wall and then bending the cable at 90 degrees to go through the wall and into the building. Option 2 Use two TP-Link TL-WA7510N High Powered Outdoor 5Ghz 15dBi Wireless antennas to connect the buildings. There is a clear line of sight at first floor level. Cost ~£100. And much easier to fit than fibre! Is using the TL-WA7510Ns overkill? Is there something more suitable? I had hoped to use some Netgear stuff, e.g. two DGN2200, one in each house and also use them to provide the wireless link between the buildings. However, in bridge mode wireless client association is not available and repeater mode with client association only supports WEP security which isn't strong enough. Is there something similar that would be up to the job? Option 3 Connect the buildings with UTP cable. My concerns here are risk of electric shock due to a difference of potential between the buildings (or are they so close this shouldn't be an issue) and protection from lightning strikes. Is fitting lighting arrestors expensive? And what can be done to ameliorate against the risk of shock? This all falls outside my area of expertise so I would really appreciate some advice.

    Read the article

  • Local admin password recovery: Windows Vista

    - by Jim Dennis
    I am faced with an unsettling situation. A friend of my father's has rather suddenly become a widower. Naturally they've taken care of the bank accounts and all the normal mundane things that people have been doing for a century or so. However, she was the computer user of the household. He was aware that they had some online banking stuff and bill paying stuff ... and that she spent lots of time on FaceBook and stuff like that. However, he doesn't know what her local passwords were (actually only vaguely aware that her couple of desktop and couple of laptop system even had passwords). He's never heard of "admin" passwords so that's no good either. In the past I've used KNOPPIX and the old LinuxCare "bootable business card" to recover NT passwords. I've never done this with MS Windows Vista. So, I'm looking for the best advice on how to do this. Naturally I do have physical access to the systems (the two laptops are charging across the room from me; and her old desktop systems are, naturally, still back at his place). Getting it right is much more important than fast or easy (I don't want to mess up those filesystems and possibly lose some photos or other stuff that he or his kids or grandkids will want). (BTW: if anyone things this is some social engineering hack to play upon the sympathies of the community to get the information I'm asking for ... think about it for a minute. I know about IRC and the "warez" boards. I know I can find this stuff out there if I dig enough. I'm just asking here because it'll hopefully be faster and, secondarily to raise awareness. As more of us put more of our lives online ... as we get older and as places like FaceBook continue to widen the appeal of computing to a broader segment of older people ... we are, as computer nerds, going to see a lot more of this. Survivors will needs us to be careful, sensitive and ethically responsible as they try to recover those bits of legacy during their bereavement. I can now tell you, first hand, it sucks!)

    Read the article

  • Init script & the green [ OK ]

    - by Lord Loh.
    I am trying to install fast-cgi for nginx on an EC2 instance. I followed the steps explained here, but that is meant for Debian and does not work out of the box for a red-hat based system. I modified the script a bit to look like - #!/bin/bash ### BEGIN INIT INFO # Provides: php-fcgi # Required-Start: $nginx # Required-Stop: $nginx # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: starts php over fcgi # Description: starts php over fcgi ### END INIT INFO . /etc/rc.d/init.d/functions (( EUID )) && echo .You need to have root priviliges.. && exit 1 BIND=/tmp/php.socket USER=nginx PHP_FCGI_CHILDREN=15 PHP_FCGI_MAX_REQUESTS=1000 PHP_CGI=/usr/bin/php-cgi PHP_CGI_NAME=`basename $PHP_CGI` PHP_CGI_ARGS="- USER=$USER PATH=/usr/bin PHP_FCGI_CHILDREN=$PHP_FCGI_CHILDREN PHP_FCGI_MAX_REQUESTS=$PHP_FCGI_MAX_REQUESTS $PHP_CGI -b $BIND" RETVAL=0 start() { echo -n "Starting PHP FastCGI: " #ORIGINAL LINE #daemon $PHP_CGI --quiet --start --background --chuid "$USER" --exec /usr/bin/env -- $PHP_CGI_ARGS #MODIFIED LINE daemon --user=$USER $PHP_CGI -b $BIND& RETVAL=$? echo [ $RETVAL -eq 0 ] && touch /var/lock/subsys/php-fcgi #echo "$PHP_CGI_NAME." } stop() { echo -n "Stopping PHP FastCGI: " killall -q -w -u $USER $PHP_CGI RETVAL=$? echo "$PHP_CGI_NAME." rm /var/lock/subsys/php-fcgi } case "$1" in start) start ;; stop) stop ;; restart) stop start ;; *) echo "Usage: php-fastcgi {start|stop|restart}" exit 1 ;; esac exit $RETVAL The problem I have now is - service php-fcgi start keeps the shell blocked. If I run service php-fcgi start & and then ps aux, I see the php-cgi process running bound to the socket. I see the start command stop only when I execute service php-fcgi stop. How do I solve this blocking issue? I have tried adding an & at the end of the line spawning the daemon. But other scripts do not seem to be doing this. This is the most complicated script I am attempting to modify yet :-( How do I get the script to display the green [ OK ]? I checked scripts like httpd and saw that all they were doing was something as shown below. But I never see a green [ OK ] when I execute php-fcgi. I also discovered that putting echo_success with functions sourced displays the green [ OK ] but I do not see any other scripts in the /etc/rc.d/init.d/ executing echo_success or echo_failure. What have I got wrong? Also, How do i specify PHP_FCGI_CHILDREN with daemon? echo [ $RETVAL -eq 0 ] && touch /var/lock/subsys/

    Read the article

  • I have a NGINX server configured to work with node.js, but many times a file of 1.03MB of js is not loaded by various browser and various pc

    - by Totty
    I'm using this in a local LAN so it should be quite fast. The nginx server use the node.js server to serve static files, so it must pass throught node.js to download the files, but that is not a problem when I'm not using the nginx. In chrome with debugger on I can see that the status is: 206 - partial content and it only has downloaded 31KB of 1.03MB. After 1.1 min it turns red and the status failed. Waiting time: 6ms Receiving: 1.1 min The headers in google chrom: Request URL:http://192.168.1.16/production/assembly/script/production.js Request Method:GET Status Code:206 Partial Content Request Headersview source Accept:*/* Accept-Charset:ISO-8859-1,utf-8;q=0.7,*;q=0.3 Accept-Encoding:gzip,deflate,sdch Accept-Language:pt-PT,pt;q=0.8,en-US;q=0.6,en;q=0.4 Connection:keep-alive Cookie:connect.sid=s%3Abls2qobcCaJ%2FyBNZwedtDR9N.0vD4Fi03H1bEdCszGsxIjjK0lZIjJhLnToWKFVxZOiE Host:192.168.1.16 If-Range:"1081715-1350053827000" Range:bytes=16090-16090 Referer:http://192.168.1.16/production/assembly/ User-Agent:Mozilla/5.0 (Windows NT 6.0) AppleWebKit/537.4 (KHTML, like Gecko) Chrome/22.0.1229.94 Safari/537.4 Response Headersview source Accept-Ranges:bytes Cache-Control:public, max-age=0 Connection:keep-alive Content-Length:1 Content-Range:bytes 16090-16090/1081715 Content-Type:application/javascript Date:Mon, 15 Oct 2012 09:18:50 GMT ETag:"1081715-1350053827000" Last-Modified:Fri, 12 Oct 2012 14:57:07 GMT Server:nginx/1.1.19 X-Powered-By:Express My nginx configurations: File 1: user totty; worker_processes 4; pid /var/run/nginx.pid; events { worker_connections 768; # multi_accept on; } http { ## # Basic Settings ## sendfile on; tcp_nopush on; tcp_nodelay on; keepalive_timeout 65; types_hash_max_size 2048; # server_tokens off; # server_names_hash_bucket_size 64; # server_name_in_redirect off; include /etc/nginx/mime.types; default_type application/octet-stream; ## # Logging Settings ## access_log /home/totty/web/production01_server/node_modules/production/_logs/_NGINX_access.txt; error_log /home/totty/web/production01_server/node_modules/production/_logs/_NGINX_error.txt; ## # Gzip Settings ## gzip on; gzip_disable "msie6"; # gzip_vary on; # gzip_proxied any; # gzip_comp_level 6; # gzip_buffers 16 8k; # gzip_http_version 1.1; # gzip_types text/plain text/css application/json application/x-javascript text/xml application/xml application/xml+rss text/javascript; ## # nginx-naxsi config ## # Uncomment it if you installed nginx-naxsi ## #include /etc/nginx/naxsi_core.rules; ## # nginx-passenger config ## # Uncomment it if you installed nginx-passenger ## #passenger_root /usr; #passenger_ruby /usr/bin/ruby; ## # Virtual Host Configs ## autoindex on; include /home/totty/web/production01_server/_deployment/nginxConfigs/server/*; } File that is included by the previous file: server { # custom location for entry # using only "/" instead of "/production/assembly" it # would allow you to go to "thatip/". In this way # we are limiting to "thatip/production/assembly/" location /production/assembly/ { # ip and port used in node.js proxy_pass http://127.0.0.1:3000/; } location /production/assembly.mongo/ { proxy_pass http://127.0.0.1:9000/; proxy_redirect off; } location /production/assembly.logs/ { autoindex on; alias /home/totty/web/production01_server/node_modules/production/_logs/; } }

    Read the article

  • Proxy Error 502 "Reason: Error reading from remote server" with Apache 2.2.3 (Debian) mod_proxy and Jetty 6.1.18

    - by Martin
    Apache is receiving requests at port :80 and proxying them to Jetty at port :8080 The proxy server received an invalid response from an upstream server The proxy server could not handle the request GET /. My dilemma: Everything works fine normally (fast requests, few seconds or few tens of seconds long requests are processed ok). Problems occur when request processing takes long (few minutes?). If I issue request instead directly to Jetty at port :8080 the request is processed OK. So problem is likely to sit somewhere between Apache and Jetty where I am using mod_proxy. How to solve this? I have already tried some "tricks" related to KeepAlive settings, without luck. Here is my current configuration, any suggestions? #keepalive Off ## I have tried this, does not help #SetEnv force-proxy-request-1.0 1 ## I have tried this, does not help #SetEnv proxy-nokeepalive 1 ## I have tried this, does not help #SetEnv proxy-initial-not-pooled 1 ## I have tried this, does not help KeepAlive 20 ## I have tried this, does not help KeepAliveTimeout 600 ## I have tried this, does not help ProxyTimeout 600 ## I have tried this, does not help NameVirtualHost *:80 <VirtualHost _default_:80> ServerAdmin [email protected] ServerName www.mydomain.fi ServerAlias mydomain.fi mydomain.com mydomain www.mydomain.com ProxyRequests On ProxyVia On <Proxy *> Order deny,allow Allow from all </Proxy> ProxyRequests Off ProxyPass / http://www.mydomain.fi:8080/ retry=1 acquire=3000 timeout=600 ProxyPassReverse / http://www.mydomain.fi:8080/ RewriteEngine On RewriteCond %{SERVER_NAME} !^www\.mydomain\.fi RewriteRule /(.*) http://www.mydomain.fi/$1 [redirect=301L] ErrorLog /var/log/apache2/error.log # Possible values include: debug, info, notice, warn, error, crit, # alert, emerg. LogLevel warn CustomLog /var/log/apache2/access.log combined ServerSignature On </VirtualHost> Here is also the debug log from a failing request: 74.125.43.99 - - [29/Sep/2010:20:15:40 +0300] "GET /?wicket:bookmarkablePage=newWindow:com.mydomain.view.application.reports.SaveReportPage HTTP/1.1" 502 355 "https://www.mydomain.fi/?wicket:interface=:0:2:::" "Mozilla/5.0 (Windows; U; Windows NT 6.1; fi; rv:1.9.2.10) Gecko/20100914 Firefox/3.6.10" [Wed Sep 29 20:20:40 2010] [error] [client 74.125.43.99] proxy: error reading status line from remote server www.mydomain.fi, referer: https://www.mydomain.fi/?wicket:interface=:0:2::: [Wed Sep 29 20:20:40 2010] [error] [client 74.125.43.99] proxy: Error reading from remote server returned by /, referer: https://www.mydomain.fi/?wicket:interface=:0:2:::

    Read the article

  • System failure - need diagnostic recommendation

    - by Ladislav Mrnka
    I have big problem with my computer. Configuration is: Intel i7 + 6x2GB OCZ DDR3 Motheboard: Asus P6T Deluxe V2, HDD controller configured to AHCI Main drive: OCZ Vertex 2 (SSD) - contains all installed programs and system Second drive: Samsung SpinPoint - contains User profiles, ProgramData, virtual machines and databases Third drive: Samsung SpinPoint - data drive + backups OS: Windows 7 Ultimate x64 I have never had any problem with this computer until now. During weekend my computer completely crashed without any reason. Each time I tried to boot to Windows I got BSOD with message BAD_SYSTEM_CONFIG_INFO and automatic restart (I didn't install any new SW or HW). But after restart main OCZ drive was disconnected (not detected by BIOS). When I turned off and on computer, the drive was again connected. It also happend every single time I tried to repair installation somehow. It ended with some error and after restart drive was disconnected. The only thing which worked was format + fresh install. After installing almost everything I wanted to install Visual Studio 2010 Ultimate (complete installation without SQL Server Express). During installation of VS itself I always get BSOD - it is too fast so I'm not able to read description. After restart it searches for all disk drives for really long time and sometimes it changes boot drive so the system is not able to start - Bootmgr not found. After reconfiguring BIOS the system starts. There is no event describing the failure in Event viewer. Installing VS 2010 is absolutely necessary for me. I need help with diagnostic. I need to find where is the problem - I expect that the problem is in OCZ drive or in HDD controller on motherboard but I don't know how to find it. All components still have valid warranty. Can you recommend me some approach or tools to find the problem? Edit: I'm still looking for source of the problem. New information is that Windows are not able to perform check disk (Chkdsk) on the SSD system drive. After restarting it always starts checking drive and in part where files are checked it fails with BSOD - BAD_SYSTEM_CONFIG_INFO. After next restart and skipping check disk tests the system runs.

    Read the article

  • Looking for personal scheduling software / todo list with rather particular requirements

    - by Cthulhu
    I've been scouring the web for a couple of (my boss') hours, looking for a piece of software that can organize my tasks in two ways. First, I have a list of bullet points / todo items I can do at any given time. Think of stuff like solve issue X, ask X about Y, write documentation about Z, etcetera. Second, I have a number of running projects I'd like to organize better, as in schedule for a certain part of a day of the week. Ideally (I think), my day would be organized as 50% spent on projects and 50% on the other small things. Now, I don't like most calendar applications (such as Outlook & friends), their UI is too 'official', not really easy to move stuff around (in my experience). I don't like most todo lists either, too static and things. I like new, fast and hip software. I've looked at GTD versions of Tiddlywiki, and I like mGSD for one particular feature. You can make lists of tasks and basically give them one of three statusses - Now (nothing required, you can do it right away), Waiting (you need someone or something before you can work on this), or the most gratifying of all, Done. I like that feature because it's a simple todo list, but indicates more accurately the things you can do right now and the things you depend on someone else for to do. Anyways, that's just a small aspect of that program - most of the other things in there I can't find a particularly good use for. If there's something like that (maybe something that works even snappier, cleaner UI), combined with an easy to use bit of scheduling software (optionally separated into two applications, but preferrably not), I think I'd like that. (Besides something like that, I also use several instances of Trac to monitor tasks and bugs and things for the various clients and projects I have to serve, and TaskCoach to monitor the amount of time I spend on each task / each client. An easy / low-maintenance time tracking software would be neat too) Of course, the software has to be free to use. I don't like shareware, trials, limited software and the like. I could develop my own too, but I'm lazy like that and there's a dozen other projects I'd like to do in my free time (neither of which I actually do). Edit: I like David Seah's printable CEO stuff, if something like that (with some video game / instant achievement / gratification) exists in software, it'd be awesome.

    Read the article

  • MySQL won't start, reinstall fails on Ubuntu 12.04

    - by Evils
    My problem started yesterday night when I tried to change the my.cnf config on my ubuntu 12.04 x64 System. I simply tried to changed the bind-address parameter from 127.0.0.1 to 0.0.0.0. A simple restart after a reboot gave this error: stop: Unknown instance: start: Job failed to start I tried to start mysql then by using 'mysqld' which outputs this: 130701 11:05:59 [Note] Plugin 'FEDERATED' is disabled. mysqld: Table 'mysql.plugin' doesn't exist 130701 11:05:59 [ERROR] Can't open the mysql.plugin table. Please run mysql_upgrade to create it. 130701 11:05:59 InnoDB: The InnoDB memory heap is disabled 130701 11:05:59 InnoDB: Mutexes and rw_locks use GCC atomic builtins 130701 11:05:59 InnoDB: Compressed tables use zlib 1.2.3.4 130701 11:05:59 InnoDB: Initializing buffer pool, size = 128.0M 130701 11:05:59 InnoDB: Completed initialization of buffer pool 130701 11:05:59 InnoDB: highest supported file format is Barracuda. 130701 11:05:59 InnoDB: Waiting for the background threads to start 130701 11:06:00 InnoDB: 5.5.31 started; log sequence number 1595675 130701 11:06:00 [Note] Server hostname (bind-address): '127.0.0.1'; port: 3306 130701 11:06:00 [Note] - '127.0.0.1' resolves to '127.0.0.1'; 130701 11:06:00 [Note] Server socket created on IP: '127.0.0.1'. 130701 11:06:00 [ERROR] Can't start server : Bind on unix socket: Permission denied 130701 11:06:00 [ERROR] Do you already have another mysqld server running on socket: /var/run/mysqld/mysqld.sock ? 130701 11:06:00 [ERROR] Aborting 130701 11:06:00 InnoDB: Starting shutdown... 130701 11:06:00 InnoDB: Shutdown completed; log sequence number 1595675 130701 11:06:00 [Note] mysqld: Shutdown complete Meanwhile I already tried to reinstall and purge the complete mysql package which results in another error which says that dpkg cant change the admins password. While this error appeared another error came with it. When trying to install something new with apt, it always says 'fopen: permission denied' right after it tries to update my man-db. This is my dmesg output: [ 6879.687998] type=1400 audit(1372669683.397:36): apparmor="STATUS" operation="profile_replace" name="/usr/sbin/mysqld" pid=9336 comm="apparmor_parser" [ 6881.323215] init: mysql main process (9340) terminated with status 1 [ 6881.323316] init: mysql respawning too fast, stopped Any help will be appreciated as this is a productive server which renders useless without mysql.

    Read the article

  • Apache's htcacheclean doesn't scale: How to tame a huge Apache disk_cache?

    - by flight
    We have an Apache setup with a huge disk_cache (500.000 entries, 50 GB disk space used). The cache grows by 16 GB every day. My problem is that the cache seems to be growing nearly as fast as it's possible to remove files and directories from the cache filesystem! The cache partition is an ext3 filesystem (100GB, "-t news") on an iSCSI storage. The Apache server (which acts as a caching proxy) is a VM. The disk_cache is configured with CacheDirLevels=2 and CacheDirLength=1, and includes variants. A typical file path is "/htcache/B/x/i_iGfmmHhxJRheg8NHcQ.header.vary/A/W/oGX3MAV3q0bWl30YmA_A.header". When I try to call htcacheclean to tame the cache (non-daemon mode, "htcacheclean-t -p/htcache -l15G"), IOwait is going through the roof for several hours. Without any visible action. Only after hours, htcacheclean starts to delete files from the cache partition, which takes a couple more hours. (A similar problem was brought up in the Apache mailing list in 2009, without a solution: http://www.mail-archive.com/[email protected]/msg42683.html) The high IOwait leads to problems with the stability of the web server (the bridge to the Tomcat backend server sometimes stalls). I came up with my own prune script, which removes files and directories from random subdirectories of the cache. Only to find that the deletion rate of the script is just slightly higher than the cache growth rate. The script takes ~10 seconds to read the a subdirectory (e.g. /htcache/B/x) and frees some 5 MB of disk space. In this 10 seconds, the cache has grown by another 2 MB. As with htcacheclean, IOwait goes up to 25% when running the prune script continuously. Any idea? Is this a problem specific to the (rather slow) iSCSI storage? Should I choose a different file system for a huge disk_cache? ext2? ext4? Are there any kernel parameter optimizations for this kind of scenario? (I already tried the deadline scheduler and a smaller read_ahead_kb, without effect).

    Read the article

  • Expendable, Redundant, Easily recoverable

    - by MeIr
    I am desperate at this point, I have been looking for "Big storage" solution for a while on my own and I can't find anything that would suite my needs. But now push came to shove. Current situation: I have about 6TB data storage (already full) - Drobo. Yesterday Drobo died on me and it put me into bad situation - I can't recover my data without buying another Drobo. From extensive research online I realized that Drobo is not the safest bet and by now it seems very poor choice. I ordered new Drobo to try to get my data back, however I don't want to be in the same situation later and continuing using Drobo promises this event to re-occur. What I am looking for: 1) Inexpensive setup. 2) Dynamically extendable - add more drives and/or replace a drive with bigger capacity. 3) Redundant - setup against 1-3 drive failure, will depend on total number of drives. For the sake of argument let's assume for every 4 drives one should be able to fail without data loss. 4) Easy data recovery - let's say unforeseen happens, I would like to be able to recover information without buying new tools or replacements - example: new Drobo. 5) Should be USB or Network Attach Storage 6) No demand on speed. Doesn't have to be fast, I am not doing video editing on the setup. However if option exists, would be nice to have a decent speed. After thoughts: I reviewed few options and FreeNAS looks nice, but it doesn't have #2 - Dynamic extendability. There are work around with Pools but it seems a bit complicated and unnecessary. More over it seems like data safety is a big question - saw some horror stories. Please advise on what options I have and what seems like an optimal solution (if any). I don't care if it has to be Windows or Linux box or any other OS and/or software that has to run on top, but simple solution is more attractive. Thank you! P.S: Feel free to ignore "After thoughts".

    Read the article

  • MongoDB and datasets that don't fit in RAM no matter how hard you shove

    - by sysadmin1138
    This is very system dependent, but chances are near certain we'll scale past some arbitrary cliff and get into Real Trouble. I'm curious what kind of rules-of-thumb exist for a good RAM to Disk-space ratio. We're planning our next round of systems, and need to make some choices regarding RAM, SSDs, and how much of each the new nodes will get. But now for some performance details! During normal workflow of a single project-run, MongoDB is hit with a very high percentage of writes (70-80%). Once the second stage of the processing pipeline hits, it's extremely high read as it needs to deduplicate records identified in the first half of processing. This is the workflow for which "keep your working set in RAM" is made for, and we're designing around that assumption. The entire dataset is continually hit with random queries from end-user derived sources; though the frequency is irregular, the size is usually pretty small (groups of 10 documents). Since this is user-facing, the replies need to be under the "bored-now" threshold of 3 seconds. This access pattern is much less likely to be in cache, so will be very likely to incur disk hits. A secondary processing workflow is high read of previous processing runs that may be days, weeks, or even months old, and is run infrequently but still needs to be zippy. Up to 100% of the documents in the previous processing run will be accessed. No amount of cache-warming can help with this, I suspect. Finished document sizes vary widely, but the median size is about 8K. The high-read portion of the normal project processing strongly suggests the use of Replicas to help distribute the Read traffic. I have read elsewhere that a 1:10 RAM-GB to HD-GB is a good rule-of-thumb for slow disks, As we are seriously considering using much faster SSDs, I'd like to know if there is a similar rule of thumb for fast disks. I know we're using Mongo in a way where cache-everything really isn't going to fly, which is why I'm looking at ways to engineer a system that can survive such usage. The entire dataset will likely be most of a TB within half a year and keep growing.

    Read the article

  • Melting Laptop Power Supply Tip

    - by AlReece45
    Several (6-7) months ago, my laptop power supply cord got a cut in it and stopped working. Having gotten cheap (and short) power supplies in the past, I decided to buy 2 brand new ones from the manufacturer (ASUS). Now, I used my laptop a little less than usual between February and March. During that time I noticed a few times that the power supply, even though plugged in, did not provide power. Often the computer would just off on me. I figured it was just that one power supply being bad. I had left the alternate at my parent's house in another state and asked them to ship it to me. Now, at work the other day I wanted to get a file off the of hard disk. So I booted it up, knowing that it had a low battery, plugged it in. During the first 2 minutes of use, I was told that the battery was low and I should plug it in. I unplugged it, inspected the end (Being plugged in, this was suspicious), and decided I shouldn't plug it back in-- the plastic on the tip was melting from the heat of the metal on the tip. The computer had simply booted up and I had the file-manager open. It had not been on for more than 10 hours. Now I know that computers tend to get pretty hot. However, the melting point of plastic is usually above 200C.. so that's much hotter than the computer should be generating. I went and bought a THIRD power supply. This time a universal one from Best Buy (it was very fast to buy and test). I tried it out on the computer and it's tip is melting as well. My older laptop that uses the universal power supply uses it perfectly (has been about a week and a part of use now). I have tried using the computer without the battery, with the same effect. Obviously, this is not a problem with the power supply. My room mate and I being trained computer techs were contemplating taking the computer apart and desoldering and resoldering on the power tip. (The computer is about 6 months out of its 2-year warranty). We're hoping that will correct the issue as I would prefer to devote my money on a Good Desktop rather than yet ANOTHER $1200+ laptop. Is there any thing I'm missing here that might cause the the tip on the power unit to melt?

    Read the article

  • Architectural advice - web camera remote access

    - by Alan Hollis
    I'm looking for architectural advice. I have a client who I've built a website for which essentially allows users to view their web cameras remotely. The current flow of data is as follows: User opens page to view web camera image. Javascript script polls url on server ( appended with unique timestamp ) every 1000ms Ftp connection is enabled for the cameras ftp user. Web camera opens ftp connection to server. Web camera begins taking photos. Web camera sends photo to ftp server. On image url request: Server reads latest image on hard drive uploaded via ftp for camera. Server deleted any older images from the server. This is working okay at the moment for a small amount of users/cameras ( about 10 users and around the same amount of cameras), but we're starting to worrying about the scalability of this approach. My original plan was instead of having the files read from the server, the web server would open up an ftp connection to the web server and read the latest images directly from there meaning we should have been able to scale horizontally fairly easily. But ftp connection establishment times were too slow ( mainly due to the fact that PHP out of the ox is unable to persist ftp connections ) and so we abandoned this approach and went straight for reading from the hard drive. The firmware provider for the cameras state they're able to build a http client which instead of using ftp to upload the image could post the image to a web server. This seems plausible enough to me, but I'm looking for some architectural advice. My current thought is a simple Nginx/PHP/Redis stack. Web camera issues post requests of latest image to Nginx/PHP and the latest image for that camera is stored in Redis. The clients can then pull the latest image from Redis which should be extremely quick as the images will always be stored in memory. The data flow would then become: User opens page to view web camera image. Javascript script polls url on server ( appended with unique timestamp ) every 1000ms Camera is sent an http request to start posting images to a provided url Web camera begins taking photos. Web camera sends post requests to server as fast as it can On image url request: Server reads latest image from redis Server tells redis to delete later image My questions are: Are there any greater overheads of transferring images via HTTP instead of FTP? Is there a simple way to calculate how many potential cameras we could have streaming at once? Is there any way to prevent potentially DOS'ing our own servers due to web camera requests? Is Redis a good solution to this problem? Should I abandon PHP/Ngix combination and go for something else? Is this proposed solution actually any good? Will adding HTTPs to the mix cause posting the image to become too slow? Thanks in advance Alan

    Read the article

< Previous Page | 263 264 265 266 267 268 269 270 271 272 273 274  | Next Page >