Search Results

Search found 12047 results on 482 pages for 'general debugging tidbits'.

Page 301/482 | < Previous Page | 297 298 299 300 301 302 303 304 305 306 307 308  | Next Page >

  • Is there a way to mark up code to tell ReSharper not to format it?

    - by adrianbanks
    I quite often use the ReSharper "Clean Up Code" command to format my code to our coding style before checking it into source control. This works well in general, but some bits of code are better formatted manually (eg. because of the indenting rules in ReSharper, things like chained linq methods or multi-line ternary operators have a strange indent that pushes them way to the right). Is there any way to mark up parts of a file to tell ReSharper not to format that area? I'm hoping for some kind of markup similar to how ReSharper suppresses other warnings/features. If not, is there some way of changing a combination of settings to get ReSharper to format the indenting correctly? EDIT: I have found this post from the ReSharper forums that says that generated code sections (as defined in the ReSharper options page) are ignored in code cleanup. Having tried it though, it doesn't seem to get ignored.

    Read the article

  • using (Fluent) NHibernate with StructureMap (or any IoCC)

    - by Andrew Bullock
    Hi, On my quest to learn NHibernate I have reached the next hurdle; how should I go about integrating it with StructureMap? Although code examples are very welcome, I'm more interested in the general procedure. What I was planning on doing was... Use Fluent NHibernate to create my class mappings for use in NHibs Configuration Implement ISession and ISessionFactory Bootstrap an instance of my ISessionFactory into StructureMap as a singleton Register ISession with StructureMap, with per-HttpRequest caching However, don't I need to call various tidy-up methods on my session instance at the end of the HttpRequest (because thats the end of its life)? If i do the tidy-up in Dispose(), will structuremap take care of this for me? If not, what am I supposed to do? Thanks Andrew

    Read the article

  • XtraReports Web Viewer not loading Parameters Popup

    - by Jan de Jager
    So were loading a a report from a saved file (this seems to not be the general way to do things), but the report viewer refuses to initialise the parameters popup. WTF!!! Here's the code: protected void Page_Load(object sender, EventArgs e) { string ReportName = Request["ReportName"]; XtraReport newReport = CreateReportFromFile(ReportName); newReport.RequestParameters = true; ReportViewerControl1.Report = newReport; } private XtraReport CreateReportFromFile(string filePath) { XtraReport report = new XtraReport(); report = XtraReport.FromFile(filePath, true); return report; }

    Read the article

  • WPF: RenderOptions.EdgeMode="Unspecified" vs "Alias" override global setting with local setting

    - by msfanboy
    Hello, in the ressource-tag of my MainWindowView.xaml I have this markup: RenderOptions.EdgeMode="Aliased" to get a general sharp look of my whole application. Using mostly rectangular shapes/controls this works fine. But for my validation error symbols I use a red ellipse with a white cross or "X" in it. The ellipse is using now the global "Aliased" settings what looks not good because I can see the pixelated border of the ellipse. Using now does NOT change anything ??? I always set in wpf local settings override global settings ?

    Read the article

  • Access Internet From My Blackberry App

    - by Ankit
    Hi all, This is my first attemp to code a blackberry app so please bear with me. I am developing an app to make it easy to access certain information from certain websites using screenscrapping. Now I am done with the ui part of the application onto the internet access part. My question is how do i access internet from my app ? I see that blackberry offers http, wifi and some other forms to access the internet ... does my app need to be worried about what mode is being used ? or as far as my app is concerned theres a general api to access the net with the logic of connecting to the internet being handled by the device itself ..? any pointers with some sample code would be much appreciated. thank you, ankit

    Read the article

  • naming conventions for buttons in user interface

    - by Samuel
    User interface for web applications in general contain various buttons for performing CRUD operations. What would be the suggested naming convention for button labels while performing the following actions.. User creation (Add User... or Add User or Add user) Event creation (Add Event... or Add Event or Add event) View users button (List All Users or List All users or List all users ) Most of the sites seem to contain the last option (e.g. Add user) where the first alphabet in the word is capitalized and rest all are lower case). What would be a better practice here?

    Read the article

  • Delphi and Microsoft ATL security issue

    - by Jens Nordenbro
    My impression is that standard Delphi uses the Win32 API. Recently Microsoft has been communicating a problem regarding ATL that requires application developers to rebuild ATL-using applications after installing an update on their machines. Will this practice be the general case also for Delphi developers, or are they in the clear with the exception of Delphi code using third party ATL COM objects? Sources: Microsoft Security: Protect your computer from the Active Template Library (ATL) security vulnerability MSDN VC++ DevCenter: Active Template Library Security Update for Developers Microsoft Security Advisory (973882): Vulnerabilities in Microsoft Active Template Library (ATL) Could Allow Remote Code Execution Microsoft Security Bulletin MS09-034 - Critical: Cumulative Security Update for Internet Explorer (972260) Microsoft Security Bulletin MS09-035 - Moderate: Vulnerabilities in Visual Studio Active Template Library Could Allow Remote Code Execution (969706)

    Read the article

  • Best approach for GPGPU/CUDA/OpenCL in Java?

    - by Frederik
    General-purpose computing on graphics processing units (GPGPU) is a very attractive concept to harness the power of the GPU for any kind of computing. I'd love to use GPGPU for image processing, particles, and fast geometric operations. Right now, it seems the two contenders in this space are CUDA and OpenCL. I'd like to know: Is OpenCL usable yet from Java on Windows/Mac? What are the libraries ways to interface to OpenCL/CUDA? Is using JNA directly an option? Am I forgetting something? Any real-world experience/examples/war stories are appreciated.

    Read the article

  • RPC Runtime exception

    - by viswanathan
    Hi I am having an application which requires inter process communication between different processes in different machines. Assume i have 2 processes in different machines which communicate usnig RPC. Everything works fine in the normal case. Now if i remove network and reconnect the same my processes still work however what happens is sometimes an RPC call(which sends a message from one process on one machine to another process on another machine) fails with an error code value of 3765269347, which may not really make any sense. This failure occurs only sometimes and i have no clue as to why this occurs. Anybody knows any reason why this may occur or general network related RPC issues. Thanks in advance.

    Read the article

  • Bulk email sender and list management API

    - by goombaloon
    I'm looking for a way to programmatically manage email lists and send large numbers of emails to these lists. The general idea would be similar to how social networking sites send email notifications when a friend posts new content. Since a user could have tens of thousands of followers, it doesn't seem realistic to send these directly from my application so I'm curious if there's a good way to handle this through a service provider. My company is using Google apps but I'm not an expert on their API. Our environment is ASP.NET MVC. Any advice is most appreciated!

    Read the article

  • How to catch all exceptions in Flex?

    - by Yaba
    When I run a Flex application in the debug flash player I get an exception pop up as soon as something unexpected happened. However when a customer uses the application he does not use the debug flash player. In this case he does not get an exception pop up, but he UI is not working. So for supportability reasons, I would like to catch any exception that can happen anywhere in the Flex UI and present an error message in a Flex internal popup. By using Java I would just encapsulate the whole UI code in a try/catch block, but with MXML applications in Flex I do not know, where I could perform such a general try/catch.

    Read the article

  • C# Solution - How many projects?

    - by Oskar Kjellin
    Hey, I googled this a little but couldn't find a good result. Right now I'm building a web site and I'm trying to make it as correct as possible from a design point of view from the beginning. The problem I'm now facing is that when deciding to start with logging I needed a project to place this code in. As I could not find a suitable place in my currect projects I thought: hey, why not a logging class library? Is there a general guideline on how many projects you should have? I know this would be a rather small project but it would be nice to entirely get it out of my way! Any hints are appreciated :)

    Read the article

  • Object Oriented Design Questions

    - by Robert
    Hello there. I am going to develop a Tic-Tac-Toe game using Java(or maybe other OO Languages).Now I have a picture in my mind about the general design. Interface: Player ,then I will be able to implement a couple of Player classes,based on how I want the opponent to be,for example,random player,intelligent player. Classes: Board class,with a two-dimensional array of integers,0 indicates open,1 indicates me,-1 indicates opponent.The evaluation function will be in here as well,to return the next best move based on the current board arrangement and whose turn it is. Refree class,which will create instance of the Board and two player instances,then get the game begin. This is a rough idea of my OO design,could anybody give me any critiques please,I find this is really beneficial,thank you very much.

    Read the article

  • QTableWidget signal cellChanged(): distinguish between user input and change by routines

    - by crabman
    i am using PyQt but my question is a general Qt one: I have a QTableWidget that is set up by the function updateTable. It writes the data from DATASET to the table when it is called. Unfortunately this causes my QTableWidget to emit the signal cellChanged() for every cell. The signal cellChanged() is connected to a function on_tableWidget_cellChanged that reads the contents of the changed cell and writes it back to DATASET. This is necessary to allow the user to change the data manually. So everytime the table is updated, its contents are written back to DATASET. Is there a way to distinguish if the cell was changed by the user or by updateTable? i thought of disconnecting on_tableWidget_cellChanged by updateTable temporarily but that seems to be a little dirty.

    Read the article

  • Good projects to learn OCaml and F#

    - by Yin Zhu
    After learning the basic syntax, reading some non-trivial code is a fast way to learn a language. We can also learn how to design a library/software during reading others' code. I have following lists. A Chess program in OCaml by Tomek Czajka. Hal Daumé has written several machine learning libraries in Ocaml. Including decision trees, logistic regression and SVM. All of them are near-production-quality code. A Chess Game Analysis program in F# in Microsoft Research. The above three are my favorites. Will you suggest some other sources? General purpose open source software are good, specialized open source like the three I list here are even more welcome.

    Read the article

  • Lighting Fast CMS, a Django based CMS. Any experiences?

    - by Melmacian
    I've just came across Lighting Fast CMS, which seems to be very promising Django based content management system. Documentation seem to be very good, even though it is still in beta stage. It also has very nice buildout based installation. Also core Components of it seem to be nicely decoupled. Does anyone have any experiences with it yet? How much one can customize it with extensions? How's extension development in general compared to Drupal or Plone? I'm hoping that I could do some projects with it instead of Plone or Drupal. Those both are great, but extending them ain't too nice. The project can be found here: http://www.lfcproject.com/

    Read the article

  • robocode engine: how to design (write) the runtime engine -- the robot world

    - by Bob
    IBM has (had) a free learn-Java program called RoboCode, in which custom robots could be written that would then do battle in a 2D space. I would like to write the environment that supports such robots, but don't know what pattern or design to use. Each robot is a thread. Each thread is given a certain (indeterminate) amount of run-time by the JRE. A robot world engine would start by building a list of the players/robots, then enter a loop that allows each player in turn to do whatever it likes: move forward, turn left, fire toward the northwest corner, whatever. Each robot is also informed of events of interest: an enemy or several enemies are within range, it has been hit by a bullet, etc. The combination of handling threads that are also event listeners (are they also producers?) confuses me; it seems that there's more to the game engine. Even some general ideas would help. TIA.

    Read the article

  • link_to syntax with rails3 (link_to_remote) and basic javascript not working in a rails3 app?

    - by z3cko
    i am wondering if the basic link_to syntax is completely broken in current rails3 master or if i am doing some wrong syntax here. = link_to "name", nil, :onlick => "alert('Hello world!');" should actually produce an alert on click. very simple. does not work on my rails3 project! (also no error output!) any ideas? for the general link_to syntax i could not find an example where i could combine a link_to_remote with a confirmation, remote and html class (see my try below) = link_to "delete", {:action => "destroy", :remote => true, :method => :delete, :confirm => "#{a.title} wirklich L&ouml;schen?" }, :class => "trash" even the rails3 api does not help me here: http://rails3api.s3.amazonaws.com/index.html help!

    Read the article

  • Java: notify() vs. notifyAll() all over again

    - by Sergey Mikhanov
    If one google for "difference between notify() and notifyAll()" then a lot of explanations will pop up (leaving apart the javadoc paragraphs). It all boils down to the number of waiting threads being waken up: one in notify() and all in notifyAll(). However (if I do understand the difference between these methods right), only one thread is always selected for further monitor acquisition; in the first case the one selected by the VM, in the second case the one selected by the system thread scheduler. The exact selection procedures for both of them (in general case) are not known to the programmer. What's is the useful difference between notify() and notifyAll() then? Am I missing something?

    Read the article

  • Advantages of compilers for functional languages over compilers for imperative languages

    - by Onorio Catenacci
    As a follow up to this question What are the advantages of built-in immutability of F# over C#?--am I correct in assuming that the F# compiler can make certain optimizations knowing that it's dealing with largely immutable code? I mean even if a developer writes "Functional C#" the compiler wouldn't know all of the immutability that the developer had tried to code in so that it couldn't make the same optimizations, right? In general would the compiler of a functional language be able to make optimizations that would not be possible with an imperative language--even one written with as much immutability as possible?

    Read the article

  • Ensuring all git commits make it back to CVS when using git-cvs

    - by Eric
    I'm using git-cvs, and my general workflow is something like this: ...write some code... $ git commit $ git cvsexportcommit -c -p -v <asdf> $ git cvs-import $CVSROOT $ git pull This generally works fine for pushing my commits back to the CVS server and keeping things in sync. However, I'm wondering how I will realize that something is missing if I happen to do the "git commit" but forget to export it to the CVS server. Is there a reasonable way to get a diff between my git repository and the CVS server, so I would know that something hadn't been committed all the way through? Or perhaps there's a better method of doing this altogether?

    Read the article

  • How can I tell if a CSV is in UTF-7 or UTF-8

    - by dru-zod
    Excel seems to save CSV files in (what I think is) UTF-7, despite the fact that most information I have read suggest that in general, you should not UTF-7. Indeed, other applications (Text pad, which lets me choose) save things in UTF-8 (or Unicode etc, but UTF-7 is not even an option). Using .NET, I read the stream, and have to provide the encoding. If I get it wrong, accented characters are replaced with question marks. If I try and let StreamReader work it out (using detectEncodingFromByteOrderMarks), it gets it wrong (at least, it does if the file has been saved in Excel). It is unlikely that anything other then Excel will be used, so I could just assume UTF-7. Are there any other options? I need to support French (accented), German, Dutch, and Norwegian characters.

    Read the article

  • Copying Pasting Word 2007 docs to HTML WYSIWYG editors

    - by Graham
    Microsoft word has a ton of proprietary formatting and styles that do not translate well to html WYSIWYG editors. When you paste them over to the html editor and try to edit the pasted info it causes all kinds of clashing styles. I want to be able to keep the general structure but leave out the proprietary stuff. Essentially I want to save clients the headache of having to completely strip out all formatting forcing them to redo all the styling again in the WYSIWYG, but at the same time avoid the conflicts that Word formatting creates. Any ideas?

    Read the article

  • REST api ambiguity and WADL

    - by JDonner
    I have a REST api that's ambiguous, something like (this isn't the specific problem, just gives an idea of the ambiguity): /toplevel/${customer_number}/some_command/more stuff /toplevel/${customer_number}/${some_product_name_anything_goes}/more stuff We've been getting away with it because our .htaccess file lists the more specific 'command' form before the general ${product_name} version, and the first match wins. Now though, we're writing a WADL, and, as you might expect, we're having trouble with our chosen tool consuming the WADL, because the API is ambiguous. My questions are: a) Does the WADL spec speak to whether they can validly represent ambiguous APIs? b) Tool support - in your experience, do tools choke on ambiguous WADLs? (if ambi. WADLs are allowed then those are weak tools but, you'd want to be on the safe side) c) Just any experience with ambiguous REST apis, most especially wrt WADLs, really. For the curious, here's the latest spec: As far as I can tell it doesn't specifically address this, I guess it really comes down to how tools handle it. Thanks.

    Read the article

  • Failing Sata HDD

    - by DaveCol
    I think my HDD is fried... Could someone confirm or help me restore it? I was using Hardware RAID 1 Configuration [2 x 160GB SATA HDD] on a CentOS 4 Installation. All of a sudden I started seeing bad sectors on the second HDD which stopped being mirrored. I have removed the RAID array and have tested with SMART which showed the following error: 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 I have no clue what this means, or if I can recover from it. Could someone give me some ideas on how to fix this, or what HDD to get to replace this? Complete SMART report: Smartctl version 5.33 [i686-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: GB0160CAABV Serial Number: 6RX58NAA Firmware Version: HPG1 User Capacity: 160,041,885,696 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Tue Oct 19 13:42:42 2010 COT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 433) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 54) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0002 097 097 000 Old_age Always - 0 4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 152 5 Reallocated_Sector_Ct 0x0033 095 095 036 Pre-fail Always - 214 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 73109713 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15133 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 154 184 Unknown_Attribute 0x0032 038 038 000 Old_age Always - 62 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 189 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 190 Unknown_Attribute 0x001a 061 055 000 Old_age Always - 656408615 194 Temperature_Celsius 0x0000 039 045 000 Old_age Offline - 39 (Lifetime Min/Max 0/22) 195 Hardware_ECC_Recovered 0x0032 070 059 000 Old_age Always - 12605265 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 1 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 62 SMART Error Log Version: 1 ATA Error Count: 4645 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4645 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 02 7b 86 b1 ea 00 00:38:52.796 READ DMA ec 03 45 00 00 00 a0 00 00:38:52.796 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:52.794 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 04 79 86 b1 ea 00 00:38:49.935 READ DMA Error 4644 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 04 79 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:49.935 READ DMA Error 4643 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4642 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4641 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15131 - # 2 Short offline Completed without error 00% 15131 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

< Previous Page | 297 298 299 300 301 302 303 304 305 306 307 308  | Next Page >