Search Results

Search found 22986 results on 920 pages for 'array difference'.

Page 327/920 | < Previous Page | 323 324 325 326 327 328 329 330 331 332 333 334  | Next Page >

  • SQL: Using a CASE Statement to update a 1000 rows at once, how??

    - by SoLoGHoST
    Ok, I would like to use a CASE STATEMENT for this, but I am lost with this. Basically, I need to update a ton of rows, but just on the "position" column. I need to update all "position" values from 0 - count(position) for each id_layout_position column per id_layout column. Here's what I got for a regular update, but I don't wanna throw this into a foreach loop, as it would take forever to do it. I'm using SMF (Simple Machines Forums), so it might look a little different, but the idea is the same, and CASE statements are supported... $smcFunc['db_query']('', ' UPDATE {db_prefix}dp_positions SET position = {int:position} WHERE id_layout_position = {int:id_layout_position} AND id_layout = {int:id_layout}', array( 'position' => $position++, 'id_layout_position' => (int) $id_layout_position, 'id_layout' => (int) $id_layout, ) ); Anyways, I need to apply some sort of CASE on this so that I can auto-increment by 1 all values that it finds and update to the next possible value. I know I'm doing this wrong, even in this QUERY. But I'm totally lost when it comes to CASES. Here's an example of a CASE being used within SMF, so you can see this and hopefully relate: $conditions = ''; foreach ($postgroups as $id => $min_posts) { $conditions .= ' WHEN posts >= ' . $min_posts . (!empty($lastMin) ? ' AND posts <= ' . $lastMin : '') . ' THEN ' . $id; $lastMin = $min_posts; } // A big fat CASE WHEN... END is faster than a zillion UPDATE's ;). $smcFunc['db_query']('', ' UPDATE {db_prefix}members SET id_post_group = CASE ' . $conditions . ' ELSE 0 END' . ($parameter1 != null ? ' WHERE ' . (is_array($parameter1) ? 'id_member IN ({array_int:members})' : 'id_member = {int:members}') : ''), array( 'members' => $parameter1, ) ); Before I do the update, I actually have a SELECT which throws everything I need into arrays like so: $disabled_sections = array(); $positions = array(); while ($row = $smcFunc['db_fetch_assoc']($request)) { if (!isset($disabled_sections[$row['id_group']][$row['id_layout']])) $disabled_sections[$row['id_group']][$row['id_layout']] = array( 'info' => $module_info[$name], 'id_layout_position' => $row['id_layout_position'] ); // Increment the positions... if (!is_null($row['position'])) { if (!isset($positions[$row['id_layout']][$row['id_layout_position']])) $positions[$row['id_layout']][$row['id_layout_position']] = 1; else $positions[$row['id_layout']][$row['id_layout_position']]++; } else $positions[$row['id_layout']][$row['id_layout_position']] = 0; } Thanks, I know if anyone can help me here it's definitely you guys and gals... Anyways, here is my question: How do I use a CASE statement in the first code example, so that I can update all of the rows in the position column from 0 - total # of rows found, that have that id_layout value and that id_layout_position value, and continue this for all different id_layout values in that table? Can I use the arrays above somehow? I'm sure I'll have to use the id_layout and id_layout_position values for this right? But how can I do this?

    Read the article

  • Objective-C vs JavaScript loop performance

    - by micadelli
    I have a PhoneGap mobile application that I need to generate an array of match combinations. In JavaScript side, the code hanged pretty soon when the array of which the combinations are generated from got a bit bigger. So, I thought I'll make a plugin to generate the combinations, passing the array of javascript objects to native side and loop it there. To my surprise the following codes executes in 150 ms (JavaScript) whereas in native side (Objective-C) it takes ~1000 ms. Does anyone know any tips for speeding up those executing times? When players exceeds 10, i.e. the length of the array of teams equals 252 it really gets slow. Those execution times mentioned above are for 10 players / 252 teams. Here's the JavaScript code: for (i = 0; i < GAME.teams.length; i += 1) { for (j = i + 1; j < GAME.teams.length; j += 1) { t1 = GAME.teams[i]; t2 = GAME.teams[j]; if ((t1.mask & t2.mask) === 0) { GAME.matches.push({ Team1: t1, Team2: t2 }); } } } ... and here's the native code: NSArray *teams = [[NSArray alloc] initWithArray: [options objectForKey:@"teams"]]; NSMutableArray *t = [[NSMutableArray alloc] init]; int mask_t1; int mask_t2; for (NSInteger i = 0; i < [teams count]; i++) { for (NSInteger j = i + 1; j < [teams count]; j++) { mask_t1 = [[[teams objectAtIndex:i] objectForKey:@"mask"] intValue]; mask_t2 = [[[teams objectAtIndex:j] objectForKey:@"mask"] intValue]; if ((mask_t1 & mask_t2) == 0) { [t insertObject:[teams objectAtIndex:i] atIndex:0]; [t insertObject:[teams objectAtIndex:j] atIndex:1]; /* NSArray *newCombination = [[NSArray alloc] initWithObjects: [teams objectAtIndex:i], [teams objectAtIndex:j], nil]; */ [combinations addObject:t]; } } } ... the array in question (GAME.teams) looks like this: { count = 2; full = 1; list = ( { index = 0; mask = 1; name = A; score = 0; }, { index = 1; mask = 2; name = B; score = 0; } ); mask = 3; name = A; }, { count = 2; full = 1; list = ( { index = 0; mask = 1; name = A; score = 0; }, { index = 2; mask = 4; name = C; score = 0; } ); mask = 5; name = A; },

    Read the article

  • Jquery image slider window resize scaling issue

    - by eb_Dev
    Hi, I have created image gallery slider, the images of which scale with the window size. My problem is I can't seem to create the right formula to ensure that the slider is at the right position when the window is scaled. If I am at the first image and the slider 'left' offset is 0 then the scaling works fine and my offset is correct, however when I am on image two and my slider is offset by say -1500 and then the window is resized, the slider is then at the wrong offset. Taking this into account I figured I could just add / subtract the new window size difference from the slider offset and therefore have everything in the right position. I was wrong. It works for the first two images but then If I am at the end of my slider on the last image I get a nice big gap between the end of the last image and the border of the page. Can someone please show my where I am going wrong please? I've spent days on this :( The relevant code is as follows: $(window).bind('resize', function(event, delta) { /* Resize work images - resizes all to document width */ resizeWorkImages('div.page.work div#work ul'); /* Position slider controls */ positionSliderControls(); /* Get the difference between the old window width and the new */ var windowDiff = (gLastWindowWidth - $(window).width()) * -1; /* Apply difference to slider left position */ var newSliderLeftPos = stripPx($('div.page.work div#work ul').css('left')) - windowDiff; /* Apply to slider */ $('div.page.work div#work ul').css('left',newSliderLeftPos+'px') /* Update gSlider settings */ gSlider.update(); /* Record new window width */ gLastWindowWidth = $(window).width(); }); Thanks, eb_dev

    Read the article

  • Server 2008 RAID5 resynching

    - by benpage
    I built a W2K8 R2 server last weekend, and built a R5 array using Disk Management, 5x 1TB drives. For the next 60 hours the status said 'Resynching (X%)' as it built the array. during this time i did read and write to the drive (slowly) and once the rebuild was complete speeds were quite fast. I was copying over some data from a USB hard drive overnight, and the machine crashed (looking in the error i believe it was the driver for the usb drive) and so the RAID5 went back to resynching, since the machine was not shut down properly. The issue is, it's been about 48 hours since that started and I'm happy to say it will take roughly 60 hours again to resynch, however.. all this time in Disk Management, the status has only said 'Resynching', not 'Resynching (X%)'. The hard drive light is going nuts, and read/writes are slow again, so I'm assuming it is actually resynching. The question is - is that a correct assumption? and why is disk management not telling me what %age it's done? Is this normal behaviour for a not-properly-shut-down r5 array?

    Read the article

  • Why does mpstat show different values when I use the interval setting?

    - by Abe
    Here's the output I get when I run mpstat: $mpstat Linux 3.2.0-30-generic (my-laptop-C650) 09/17/2012 _x86_64_ (2 CPU) 05:32:01 PM CPU %usr %nice %sys %iowait %irq %soft %steal %guest %idle 05:32:01 PM all 9.16 0.08 2.69 2.00 0.00 0.04 0.00 0.00 86.02 And here's what I get when I run it with a one-second interval: $mpstat 1 05:31:51 PM CPU %usr %nice %sys %iowait %irq %soft %steal %guest %idle 05:31:52 PM all 1.52 0.00 1.01 0.00 0.00 0.00 0.00 0.00 97.47 05:31:53 PM all 2.04 0.00 1.02 0.00 0.00 0.00 0.00 0.00 96.94 05:31:54 PM all 1.50 0.00 1.50 0.00 0.00 0.00 0.00 0.00 97.00 Why does the first process show the processor as 86% idle, and the second show it as ~97% idle? I've tried this in a bunch of different configurations, and it's not a real difference in CPU usage -- unless mpstat itself is making the difference. Which number should I trust?

    Read the article

  • IIS7 bulk bindings in vbscript , how to remove a binding

    - by minus4
    I have a script to manage adding over a thousand domains to a single site bindings, this has gone fine, but now client wants about 20 of them removed, Microsoft programmers don't think it would be nice to sort the bindings alphabetically, so does anyone know the code to remove the domains ( array list ) in bulk please. this is what i am using: Set adminManager = createObject("Microsoft.ApplicationHost.WritableAdminManager") adminManager.CommitPath = "MACHINE/WEBROOT/APPHOST" Set sitesSection = adminManager.GetAdminSection("system.applicationHost/sites", "MACHINE/WEBROOT/APPHOST") Set sitesCollection = sitesSection.Collection siteElementPos = FindElement(sitesCollection, "site", Array("name", "microsites")) If siteElementPos = -1 Then WScript.Echo "Element not found!" WScript.Quit End If on error resume next Set siteElement = sitesCollection.Item(siteElementPos) Set bindingsCollection = siteElement.ChildElements.Item("bindings").Collection Dim arrFileNames : arrFileNames = Array("list of domains") Dim objDict : Set objDict = CreateObject("Scripting.Dictionary") Dim strFileName, strTemp For Each strFileName In arrFileNames Set bindingElement = bindingsCollection.CreateNewElement("binding") bindingElement.Properties.Item("protocol").Value = "http" bindingElement.Properties.Item("bindingInformation").Value = "192.168.100.19:80:" & strFileName bindingsCollection.AddElement(bindingElement) Next adminManager.CommitChanges() WScript.Echo "Job Completed" WScript.Quit Function FindElement(collection, elementTagName, valuesToMatch) For i = 0 To CInt(collection.Count) - 1 Set element = collection.Item(i) If element.Name = elementTagName Then matches = True For iVal = 0 To UBound(valuesToMatch) Step 2 Set property = element.GetPropertyByName(valuesToMatch(iVal)) value = property.Value If Not IsNull(value) Then value = CStr(value) End If If Not value = CStr(valuesToMatch(iVal + 1)) Then matches = False Exit For End If Next If matches Then Exit For End If End If Next If matches Then FindElement = i Else FindElement = -1 End If End Function so as you can see it is easy to add, but i can find no code or manual or instructions for the removal. i cant seem to run appcmd either. at first i tried creating a batch file using the appcmd but this never worked, saying appcmd can not be found. thanks

    Read the article

  • raid md device is not remove from memory, how to overcome this problem

    - by santhosha
    i create raid 10 , i removed two arrays form md11 one by one , after that i going to editing the contents those are mounted ( it will be not responding stage), after i try for remove arrays those are left it is shows device or resource busy ( is not removed from memory). i try to terminate process this is also not work, i absorve from 4 days resync will be 8.0% it can not modifying. cat /proc/mdstat Personalities : [raid1] [raid0] [raid6] [raid5] [raid4] [linear] [raid10] md11 : active raid10 sde1[3] sdj14 286743936 blocks 64K chunks 2 near-copies [4/1] [___U] [1:2:3:0] [=...................] resync = 8.0% (23210368/286743936) finish=289392.6min speed=15K/sec mdadm -D /dev/md11 /dev/md11: Version : 00.90.03 Creation Time : Sun Jan 16 16:20:01 2011 Raid Level : raid10 Array Size : 286743936 (273.46 GiB 293.63 GB) Device Size : 143371968 (136.73 GiB 146.81 GB) Raid Devices : 4 Total Devices : 2 Preferred Minor : 11 Persistence : Superblock is persistent Update Time : Sun Jan 16 16:56:07 2011 State : active, degraded, resyncing Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 Layout : near=2, far=1 Chunk Size : 64K Rebuild Status : 8% complete UUID : 5e124ea4:79a01181:dc4110d3:a48576ea Events : 0.23 Number Major Minor RaidDevice State 0 0 0 0 removed 1 0 0 1 removed 4 8 145 2 faulty spare rebuilding /dev/sdj1 3 8 65 3 active sync /dev/sde1 umount /dev/md11 umount: /dev/md11: not mounted mdadm -S /dev/md11 mdadm: fail to stop array /dev/md11: Device or resource busy lsof /dev/md11 COMMAND PID USER FD TYPE DEVICE SIZE NODE NAME mount 2128 root 3r BLK 9,11 4058 /dev/md11 mount 5018 root 3r BLK 9,11 4058 /dev/md11 mdadm 27605 root 3r BLK 9,11 4058 /dev/md11 mount 30562 root 3r BLK 9,11 4058 /dev/md11 badblocks 30591 root 3r BLK 9,11 4058 /dev/md11 kill -9 2128 kill -9 5018 kill -9 27605 kill -9 30562 kill -3 30591 mdadm -S /dev/md11 mdadm: fail to stop array /dev/md11: Device or resource busy lsof /dev/md11 COMMAND PID USER FD TYPE DEVICE SIZE NODE NAME mount 2128 root 3r BLK 9,11 4058 /dev/md11 mount 5018 root 3r BLK 9,11 4058 /dev/md11 mdadm 27605 root 3r BLK 9,11 4058 /dev/md11 mount 30562 root 3r BLK 9,11 4058 /dev/md11 badblocks 30591 root 3r BLK 9,11 4058 /dev/md11 cat /proc/mdstat Personalities : [raid1] [raid0] [raid6] [raid5] [raid4] [linear] [raid10] md11 : active raid10 sde1[3] sdj14 286743936 blocks 64K chunks 2 near-copies [4/1] [___U] [1:2:3:0] [=...................] resync = 8.0% (23210368/286743936) finish=289392.6min speed=15K/sec

    Read the article

  • Dell Poweredge 2600 RAID Transfer How-to

    - by DCookie
    Help, please! Hardware: Dell Poweredge 2600 PERC 4 SCSI Drives, 1 standalone 3 in a RAID 5 configuration OS: Windows 2000 Server In other words, a fairly old system. Anyway, we are in the process of taking over support for this site. The current tech wants out and is fading from view fast, so we need to solve this problem: The standalone disk (where the OS was) failed. We've replaced the disk, installed the OS, but need to know exactly how to proceed from here. I've never worked with a RAID system before, so I don't want to touch anything without knowing what I'm doing. We are not certain if the site will want us to attempt to recover the array or wait for the old tech to become available. We have replaced the server with a temporary box, and recovered MOST of the data from an online backup service. However, the other tech failed to backup a part of the data and the only copy of it is on this RAID array. Hence, our caution. We have poked minimally around in the boot-up PERC config utility, and it seems to me that that's where we'll need to be to reclaim the array. Another possibility is that there is some Dell software for the RAID controller we need to acquire. Can anyone provide clues as to how to proceed from here? Any help GREATLY appreciated.

    Read the article

  • Intel P6100 CPU and Mobile Intel® HM55 Express Chipset

    - by Christopher Painter
    I have an Asus K52F-BBR5 notebook that uses an Intel P6100 ( 2GHZ 15x multiplier) and HM55 Express Chipset. I'm looking to replace it's 3GB with 8GB. The Crucial database seems to indicate that a PC3-8500 CAS 7 and PC3-10666 CAS 9 will both work. I'm not up to date on the latest DDR3 nomencalature and I'm wondering which would provide better performance. The price difference is negligible. Drawing on past experiences from many many years ago I could make an argument for either based on sync/async bus speed arguments and CAS latency differences but the truth is I don't know enough about the HM55 chipset to know which would be the correct choice. Does anyone know the answer or point me to information that would help me make the choice? I'm pretty sure the performance difference will be somewhat negligible also but still I'd like to make the optimal choice.

    Read the article

  • Solaris: detect hotswap SATA disk insert

    - by growse
    What's the method used on Solaris to get the system to rescan for new disks that have been hot-plugged on a SATA controller? I've got an HP X1600 NAS which had 9 drives configred in a ZFS pool. I've added 3 disks, but the format command still only shows the original 9. When I plugged them in, I saw this: cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=12 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=11 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=10 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO But can't figure out how to get the format command to see them so I know they've been detected by the system.

    Read the article

  • external drive enclosure -> software RAID 5?

    - by memilanuk
    Hello all, I have two older PCs on my LAN posing as 'servers'... one running FreeNAS off a USB stick using three 500GB hdds in a ZFS RAID-Z pool serving as storage for the LAN and one running Debian Lenny with an 80GB drive used as a general purpose 'tinker' box that I can ssh into, etc. Problem is that the SMART report for one of those 500GB drives in the FreeNAS box is showing some pre-failure attributes, and the whole array is a little small anyways. Rather than simply replace one 500GB drive with another 500GB drive, and have no backup of the file server, I'd like to upgrade all the drives to 2TB ones - but I have no where to store that much data in the mean while. As such, I started looking at getting a 4-bay external drive enclosure with an eSATA card for the Debian box, with the hopes of creating a RAID5 + LVM setup using those drives and backing the data up to that external drive enclosure. After the backup is done, replace the drives in the FreeNAS box and rebuild the array there and mirror the data back. Then, I'd have both the primary storage (on the FreeNAS box) and a backup (which I don't have currently) using the external drive enclosure on the Debian box. My big question is... most of these external drive boxes seem to claim support for JBOD, RAID 0, 1, 10, 5, etc. - should I presume that is simply fake RAID like many commodity mobos have, and not really usable in Linux? In that case, with all the drives hanging off the one eSATA connection, will Linux (specifically Debian Squeeze, as I plan on upgrading that box here shortly) see all four drives, or just the first one? Will I be able to configure them in a RAID5 array as desired? Thanks, Monte

    Read the article

  • Selection between two laptops for casual gaming [closed]

    - by Prabhpreet
    I have selected two laptops that meet my budget. Here are the differences: Laptop #1: 4GB Ram, Intel Core i5 2450M 2nd Gen processor w/ 2.5 Ghz clockspeed NVIDIA GeForce GT 520MX DDR3 1 GB Dedicated Graphics 750 GB SATA II Hard disk USB 2.0 Ports 6 hrs battery life Laptop #2: 4 GB Ram, Intel Core i5 3210M 3rd Gen processor w/ 2.5 Ghz clockspeed Integrated Intel HD Graphics 4000 500 GB SATA Hard disk USB 3.0 Ports 3 hrs battery life (This concerns me) First and foremost, does dedicated graphics matter for a casual gamer like me? Secondly, does the generation of the processors make a difference despite the same clockspeed. Thirdly, do usb 3.0 ports make a difference? And lastly, which laptop is more future proof? Please help me out. Thanks!

    Read the article

  • What are the "N" versions of Windows 8?

    - by Gustavo Gondim
    Microsoft just released the final Windows 8 versions for MSDN members, before its consumer release in october. Anyway, I am a MSDN member. Today I went to see my downloads page and I found a list of the new versions to be downloaded. Windows 8 Windows 8 N Windows 8 Pro Windows 8 Pro N Windows 8 Enterprise Windows 8 Enterprise N I know the difference between the versions "Windows 8", "Windows 8 Pro" and "Windows 8 Enterprise", which you easily find at wikipedia. But, I really need to know the difference between these versions and the "N" versions before download one of them.

    Read the article

  • Reinserted a RAID disk. Defined as foreign. Is import or clear the correct choice?

    - by Petrus
    I have re-inserted a RAID disk, on a DELL server with Windows Server 2008. The drive-status indicator was changing between a green and amber light, and the monitor gave the following message: There are offline or missing virtual drives with preserved cache. Please check the cables and ensure that all drives are present. Press any key to enter the configuration utility. I pressed a key and the PERC 6/I Integrated BIOS Configuration Utility showed that the RAID Status for that disk was Offline. After reinsertion of the disk the monitor is giving the following message: Foreign configuration(s) found on adapter. Press any key to continue or ‘C’ load the configuration utility, or press ‘F’ to import foreign configuration(s) and continue. After checking around on the net I am uncertain if I should choose import or clear. I cannot find out if an import means importing information from the array/system to the now foreign disk or the other way, i.e. importing information from the foreign disk to the array/system that was actually working fine. Also; if clear is a necessary thing to do ahead of a rebuild of that disk, or if clear means to clear the system to somehow make it ready to import the information from the foreign disk to the array/system, which is not what I want. I imagine that making the wrong choice here might be fatal. Please help clearing this out by telling what to choose and why.

    Read the article

  • Why do Finder and du report different file size?

    - by flipdoubt
    I am writing a geektool 3 script to show the size of a particular VMware Fusion virtual machine. Get Info in Finder says the file is "52.91 GB". I run the following du command to get the file size: > du -hs ~/Documents/Virtual\ Machines.localized/MY-PRECIOUS-7.vmwarevm | awk '{print $1}' This du -hs command returns the file size as "49G". What accounts for the difference from what Finder reports? Alternatively, I have tried replacing the -s option with the -d option like so: du -hd ~/Documents/Virtual\ Machines.localized/MY-PRECIOUS-7.vmwarevm | awk '{print $1}' This du -hd command returns the file size as "59G". What accounts for the difference between Finder, du -hd, and du -hs? Also, this du -hd command produces no output in geektool 3. What gives?

    Read the article

  • Bitlocker-to-go on fixed drive

    - by Unsigned
    Scenario Two drives are connected to a computer. One via a SATA-to-USB interface, the other directly via a SATA-to-eSATA cable. The drive on USB appears as a removable drive, the drive on eSATA appears as a fixed drive. Both use NTFS. The USB drive offers Bitlocker-To-Go, the eSATA drive only offers BitLocker. Question It is my understanding that drives encrypted with BitLocker-To-Go include an app to allow Windows XP read-only access to the volume. Is this the only difference, and is there a way to use Bitlocker-To-Go on the eSATA drive? Update Another difference is found here: The recovery key is required when a BitLocker-protected fixed data drive configured for automatic unlocking is moved to another computer.[1] Assuming that does not apply to removable drives.

    Read the article

  • Vim */dyn support

    - by galymzhan
    What does mean the plus sign before */dyn in the :version command's output, e.g.: +python/dyn +python3/dyn +ruby/dyn +tcl/dyn I didn't find any useful documentation on it. When I run :echo has('python3') Vim returns 0. When I run :python3 print('hi') it says E370: Could not load library python31.dll meaning I should install python (as I understand). So I just can't see the difference between -*/dyn and +*/dyn. What does plus sign give to us? Also what's the difference from dyn-less feature, e.g. +python?

    Read the article

  • Raid-5 Performance per spindle scaling

    - by Bill N.
    So I am stuck in a corner, I have a storage project that is limited to 24 spindles, and requires heavy random Write (the corresponding read side is purely sequential). Needs every bit of space on my Drives, ~13TB total in a n-1 raid-5, and has to go fast, over 2GB/s sort of fast. The obvious answer is to use a Stripe/Concat (Raid-0/1), or better yet a raid-10 in place of the raid-5, but that is disallowed for reasons beyond my control. So I am here asking for help in getting a sub optimal configuration to be as good as it can be. The array built on direct attached SAS-2 10K rpm drives, backed by a ARECA 18xx series controller with 4GB of cache. 64k array stripes and an 4K stripe aligned XFS File system, with 24 Allocation groups (to avoid some of the penalty for being raid 5). The heart of my question is this: In the same setup with 6 spindles/AG's I see a near disk limited performance on the write, ~100MB/s per spindle, at 12 spindles I see that drop to ~80MB/s and at 24 ~60MB/s. I would expect that with a distributed parity and matched AG's, the performance should scale with the # of spindles, or be worse at small spindle counts, but this array is doing the opposite. What am I missing ? Should Raid-5 performance scale with # of spindles ? Many thanks for your answers and any ideas, input, or guidance. --Bill Edit: Improving RAID performance The other relevant thread I was able to find, discusses some of the same issues in the answers, though it still leaves me with out an answer on the performance scaling.

    Read the article

  • Windows file compare (FC) spurious differences

    - by user165568
    I'm getting differences like this: a.txt Betty Davis Cathy Edwards b.txt Betty Davis Cathy Edwards There are only two lines listed in the diff (which doesn't make sense). No CR/LF/Newline funnies. The difference just moves down if I delete lines. Same problem on Win7 and Win2K. The difference seems to go away if I remove all empty lines from the files. The empty lines are correctly terminiated too. Using /C /W (ignore case, ignore whitespace) Has anyone seen this before? What am I doing wrong? How can I fix it? There are real diffs in the file -missing, extra, or re-spelled names- but the files are byte-for-byte identical at the listed diff.

    Read the article

  • Using using a DVI instead of a VGA increase computer screen monitor resolution

    - by Jessica M.
    This is for a computer screen. Both my video card and computer screen have DVI ports on them but I'm using a VGA. I'm wondering if there would be a difference if i switch from VGA to DVI. My current resolution is 1920x1080 with the VGA cord. will my resolution increase if i switch to a DVI? Are there any advantage of switching from VGA to DVI? If there will be a difference if i switch, I've read there are 5 different type of DVI cables. how do I know which one to buy?

    Read the article

  • Will my laptop be ok with this different laptop charger?

    - by tidbits
    So the original laptop charger broke and I switched to a charger from a laptop that I no longer use. The specifications from each are: Original Input:AC 100-240V 1.5A 50-60Hz Output: DC 19V 3.42A Other Charger Input: AC 100-240V 1.5A 50-60Hz Output: 20V 3.25A Yes, the polarity is the same. Also, the wattage has a difference of .02 from what I understand. Is wattage ever important, and more specifically, a wattage difference of that size. Feel free to ask me any other questions about the chargers and I'll answer them to the best of my ability.

    Read the article

  • Problem with the hosts file in Windows XP

    - by Mee
    I have a computer with Windows XP SP2 with a weird problem. The hosts file doesn't work. No matter what I do, adding or removing entries in the file doesn't make any difference, pinging the added names times out. I tried flushing the DNS cache (using ipconfig /flushdns) but that didn't work, I even tried to restart the DNS client service but that made no difference too. Removing entries also has no effect, I ping the names and I get a reply. Help!!! Edit: Thanks for your answer guys, but the problem is more complicated than this. It seems I'll have to reinstall Windows.

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • Recovering Data from a Linkstation LS-WXL/R1

    - by kingkool68
    I've been running a Buffalo Linkstation LS-WXL/R1 in RAID1 for a few weeks. Two nights ago we had a brief power outage. Yesterday when I tried to mount the disk it couldn't be found. I logged in to the web admin and it couldn't see any storage attached and no arrays available. Well this sucks. I ended up taking the disks out and mounting them to an Ubuntu virtual machine. They how up as an Array but I can't start the Array to the best of my limited knowledge. I could still see the 6 partitions, so I'm confident the data is there. I can use Photorec (http://www.cgsecurity.org/wiki/PhotoRec) to recover most of the files I want, it just takes some time. Could I make an image of the data partition and mount that in Ubuntu so I can get at the data I want through the file system? 95% of the data on my Linkstation LS-WXL/R1 is backup. I just put a few folders of images on there that I need to get back. I'm already preparing to format the disks when I'm done and re-building the RAID1 array from scratch. Any advice would be appreciated.

    Read the article

< Previous Page | 323 324 325 326 327 328 329 330 331 332 333 334  | Next Page >