Search Results

Search found 28989 results on 1160 pages for 'modal view controller'.

Page 380/1160 | < Previous Page | 376 377 378 379 380 381 382 383 384 385 386 387  | Next Page >

  • Simultaneous read/write to RAID array slows server to a crawl

    - by Jeff Leyser
    Fairly beefy NFS/SMB server (32GB RAM, 2 Xeon quad cores) with LSI MegaRAID 8888ELP controlling 12 drives configured into 3 different arrays. 5 2TB drives are grouped into a RAID 6 array. As expected, write performance to the array is slow. However, sustained, simultaneous read/write to the array (wether through NFS or done locally) seems to practically block any other access to anything else on the controller. For example, if I do: cp /home/joe/BigFile /home/joe/BigFileCopy where BigFile is 20G, then even a simple ls /home/jane will take many 10s of seconds to complete. In addition, an ls /backup will also take many tens of seconds, even though /backup is a different array on the same controller. As soon as the cp is done, everything is back to normal. cp /home/joe/BigFile /backup/BigFile does not exhibit this behavior. It's only when doing read/write to the same array.

    Read the article

  • Windows Disk I/O Analysis

    - by Jonathon
    It appears that we are having a problem with the disk i/o speed on our Windows 2003 Enterprise Edition server (64-bit). As we were initializing a database that created two 1G tablespaces on 3 different machines, it became obvious that the two smaller machines (each 32-bit Windows 2003 Standard Edition with less RAM) killed the larger machine when creating the files. The larger machine took 10x as long to create the tablespaces than did the other machines. Now, I am left wondering how that could be. What programs or scripts would you guys recommend for tracking down the I/O problem? I think the issue may be with the controller card (all boxes are hardware RAID 10, but have different controller cards), but I would like to check the actual disk I/O speed as well, so I have some hard numbers to work with. Any help would be appreciated.

    Read the article

  • Libraries merged folder views

    - by Stigma
    So I pretty much love the Windows 7 Libraries feature, and saw one use for them that I thought would be perfect, but I can't seem to manage it. Basically, a merged view of different folder structures. Suppose I make a new generic library and add three locations to it: C:\Test\, D:\Test\ and D:\temp\Test\. Now, these may look somewhat okay as long as there are no duplicates in these folders. (It wants to group them based on the included directory, which one can work around by looking on google - I don't have the precise trick on hand I am afraid.) But when you get collisions and, say, two of those directories have a Sub directory in them, stuff becomes unusable (assuming Arrange by: Folder view). You'll have multiple folders listed named Sub, which is pretty useless when looking for data. I want folders to get 'merged', which ought to be possible somehow since it can create these merged views based on artist, album etc in other views. So all subdirectories that are double (and recursively checking for doubles inside those, etc) ought to be merged for as far the View is concerned. If files have a collision, I don't really care what happens - hide one, show both, filter out duplicates, whatever. (Although an option would be nice...) Anyhow, is there anyone who knows how to get such a 'merged folder structure' functionality for Libraries? It would be really useful for me.

    Read the article

  • Is it possible to install Windows Server 2012 on a Dell PowerEdge with PERC S100 card?

    - by Warren P
    According to Dell's own website, the Windows Server 2012 media driver "inbox" does not contain drivers for the Perc S100 controller that is in a Dell PowerEdge T110 II server we'd like to evaluate with Server 2012. I have found drivers only for Server 2008 R2, which is what the server is currently running. Is it possible to upgrade this server? (Booting up the Server 2012 DVD image leads to the expected result that it can not locate the system's hard drives or its hard drive controller card, as the drivers for the PERC S100 are not on the installation DVD image.)

    Read the article

  • KVM Virtual guest Paused on Reboot

    - by David Hamilton
    I'm running REHL 6 and just installed a Ubuntu Server Guest via KVM set to start at boot. This works correctly and the guest loads, but it loads "paused" and requires that I manually un-pause it. Can someone give me a hint as to how I can I get the Guest OS to actually become active on boot? Here is the libvert dump as requested...Also tried libvert auto-start --- no effect. <domain type='kvm' id='1'> <name>MailServer</name> <uuid>a61dae75-1f5c-d536-718f-3c615d9b4868</uuid> <memory>4194304</memory> <currentMemory>4194304</currentMemory> <vcpu>4</vcpu> <os> <type arch='x86_64' machine='rhel6.0.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw' cache='none'/> <source file='/home/MailServer/MailServer-1.img'/> <target dev='hda' bus='ide'/> <alias name='ide0-0-0'/> <address type='drive' controller='0' bus='0' unit='0'/> </disk> <disk type='block' device='cdrom'> <driver name='qemu' type='raw'/> <target dev='hdc' bus='ide'/> <readonly/> <alias name='ide0-1-0'/> <address type='drive' controller='0' bus='1' unit='0'/> </disk> <controller type='ide' index='0'> <alias name='ide0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x1'/> </controller> <interface type='bridge'> <mac address='52:54:00:cd:f9:9f'/> <source bridge='br0'/> <target dev='vnet0'/> <model type='virtio'/> <alias name='net0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <serial type='pty'> <source path='/dev/pts/1'/> <target port='0'/> <alias name='serial0'/> </serial> <console type='pty' tty='/dev/pts/1'> <source path='/dev/pts/1'/> <target port='0'/> <alias name='serial0'/> </console> <input type='mouse' bus='ps2'/> <graphics type='vnc' port='5900' autoport='yes'/> <sound model='ac97'> <alias name='sound0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </sound> <video> <model type='cirrus' vram='9216' heads='1'/> <alias name='video0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/> </video> <memballoon model='virtio'> <alias name='balloon0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/> </memballoon> </devices> <seclabel type='dynamic' model='selinux'> <label>system_u:system_r:svirt_t:s0:c211,c271</label> <imagelabel>system_u:object_r:svirt_image_t:s0:c211,c271</imagelabel> </seclabel></domain>

    Read the article

  • CPU load, USB connection vs. NIC

    - by T.J. Crowder
    In general, and understanding the answer may vary by manufacturer and model (and driver, and...), in consumer-grade workstations with integrated NICs, does the NIC rely on the CPU for a lot of help (as is typically the case with a USB controller, for instance), or is it fairly intelligent and capable on its own (like, say, the typical Firewire controller)? Or is the question too general to answer? (If it matters, you can assume Linux.) Background: I'm looking at connecting a device (digital television capture) that will be delivering ~20-50 Mbit/sec of data to a somewhat under-powered workstation. I can get a USB 2 High-speed device, or a network-attached device, and am interested in avoiding impacting the CPU where possible. Obviously, if it's a 100Mbit NIC, that's roughly half its theoretical inbound bandwidth, whereas it's only roughly a tenth of the 480 Mbit/second the USB 2 "High Speed" interface. But if the latter requires a lot of CPU support and the former doesn't...

    Read the article

  • How can I make my monitor run at it's native resolution under Kubuntu 9.10?

    - by Adam Matan
    Hi, I have installed Kubuntu 9.10 afresh on an HP desktop computer with a Samsung SyncMaster 2243 and Intel integrated graphics card. The screen resolution is fixed on 1280x1024 instead of the native 1680x1050, which makes my eyes bleed. $ lspci -k |grep "VGA" -A2 00:02.0 VGA compatible controller: Intel Corporation 82G33/G31 Express Integrated Graphics Controller (rev 10) Kernel driver in use: i915 Kernel modules: i915 and my xorg.conf: /etc/X11$ cat xorg.conf Section "Device" Identifier "Configured Video Device" Driver "vesa" EndSection Section "Monitor" Identifier "Configured Monitor" EndSection Section "Screen" Identifier "Default Screen" Monitor "Configured Monitor" Device "Configured Video Device" EndSection Any ideas how to make this driver work? I found no working solutions on Google searches. Thanks, Adam

    Read the article

  • How to set up Dell OMSA tools on Debian 6 (Squeeze) (PE2950)

    - by javano
    I assume I have set up them up incorrectly or am missing a library or dependency. When I log into the OMSA web interface I can't see anything Also, omreport tells me nothing; root@box:~# omreport storage controller No controllers found I assume these two will use the same source of information so what ever is wrong will fix them both. I set up OMSA as per these instructions. Also I have compiled MegaCLI (as this is a PowerEdge 2950 with a Perc 6/i controller) and I have used that to update the RAID firmware, so that works, but the Dell tools aren't. What have I missed during set up? root@kvm1:~# cat /etc/issue Debian GNU/Linux 6.0 \n \l root@kvm1:~# uname -a Linux kvm1.mivoice.cust.vostron.net 3.4.9 #1 SMP Wed Aug 22 19:08:46 BST 2012 x86_64 GNU/Linux

    Read the article

  • Testing for disk write

    - by Montecristo
    I'm writing an application for storing lots of images (size <5MB) on an ext3 filesystem, this is what I have for now. After some searching here on serverfault I have decided for a structure of directories like this: 000/000/000000001.jpg ... 236/519/236519107.jpg This structure will allow me to save up to 1'000'000'000 images as I'll store a max of 1'000 images in each leaf. I've created it, from a theoretical point of view seems ok to me (though I've no experience on this), but I want to find out what will happen when there will be directories full of files in there. A question about creating this structure: is it better to create it all in one go (takes approx 50 minutes on my pc) or should I create directories as they are needed? From a developer point of view I think the first option is better (no extra waiting time for the user), but from a sysadmin point of view, is this ok? I've thought I could do as if the filesystem is already under the running application, I'll make a script that will save images as fast as it can, monitoring things as follows: how much time does it take for an image to be saved when there is no or little space used? how does this change when the space starts to be used up? how much time does it take for an image to be read from a random leaf? Does this change a lot when there are lots of files? Does launching this command sync; echo 3 | sudo tee /proc/sys/vm/drop_caches has any sense at all? Is this the only thing I have to do to have a clean start if I want to start over again with my tests? Do you have any suggestions or corrections?

    Read the article

  • Cannot access Network Shares on Windows Server 2008 running VisualSVN Server

    - by mwillmott
    I have installed VisualSVN server on Windows Server 2008. The server is part of a domain but not the domain controller, it is just a data server and now an SVN server. VisualSVN uses port 80 and can only be access from inside the network (i do i by going to the dns name of the server). However, ever since i have installed this, other computers on the network can no longer access the shared folders on the server EXCEPT the domain controller which has no problems accessing the shares. I am stumped, i am guessing it is something to do with Apache running and not using host-headers (or whatever the Apache equivalent may be) but just being bound to the servers DNS name or IP. Any suggestions?

    Read the article

  • Win7 x64 unresponsive for a minute or so. HD failing?

    - by Gaia
    On a fully updated Win7 x64, every so often the system stalls for a minute or so. This has been going on for a couple months now. By stalling I mean the mouse responds and I can move windows around, but any window, any program, that is open becomes whiteish when I select it AND any new programs will not open. It doesn't matter what kind of program it is. When the stall stops all clicks I made (open new programs for example) take effect. Nothing shows up consistently (as in every time this happens) in the event log. Today though I was able to find something, but it doesn't reveal much other than the "system was unresponsive". It's a 7009 for "A timeout was reached (30000 milliseconds) while waiting for the Windows Error Reporting Service service to connect." It doesn't matter if I have any USB devices plug-in or not. I've ran Microsoft Security Essentials and Malwarebytes. While the machine is unresponsive, I've noticed that Drive D (the other partition on the single internal HD in this laptop) is displayed like this in explorer. This never occurs with Drive C or any other drive on the machine. . SMART report for the physical drive: Read benchmark by HD Tune 5 Pro, probably the most telling piece of the puzzle. Isn't this alone enough to see there is a problem with the drive, regardless of whether the unresponsiveness is caused by such purported problem? Here is a short hardware report: Computer: LENOVO ThinkPad T520 CPU: Intel Core i5-2520M (Sandy Bridge-MB SV, J1) 2500 MHz (25.00x100.0) @ 797 MHz (8.00x99.7) Motherboard: LENOVO 423946U Chipset: Intel QM67 (Cougar Point) [B3] Memory: 8192 MBytes @ 664 MHz, 9.0-9-9-24 - 4096 MB PC10600 DDR3 SDRAM - Samsung M471B5273CH0-CH9 - 4096 MB PC10600 DDR3 SDRAM - Patriot Memory (PDP Systems) PSD34G13332S Graphics: Intel Sandy Bridge-MB GT2+ - Integrated Graphics Controller [D2/J1/Q0] [Lenovo] Intel HD Graphics 3000 (Sandy Bridge GT2+), 3937912 KB Drive: ST320LT007, 312.6 GB, Serial ATA 3Gb/s Sound: Intel Cougar Point PCH - High Definition Audio Controller [B2] Network: Intel 82579LM (Lewisville) Gigabit Ethernet Controller Network: Intel Centrino Advanced-N 6205 AGN 2x2 HMC OS: Microsoft Windows 7 Professional (x64) Build 7601 The drive less than 1 year old. Do I have a defective drive? Seagate Tools diag says there is nothing wrong with the drive... UPDATE: I noticed that the windows error reporting service entered the running state then the stopped state and the space between the two events was exactly 2 minutes. Which error it was trying to report I don't know. I check the "Reliability Monitor" and it shows no errors to be reported. I've disabled the windows error reporting service to see if the problem stops.

    Read the article

  • Wireless technology - which is better: more single radio APs or less dual radio APs?

    - by gert_78
    We are currently talking to vendors of wireless solutions for a wireless deployment in a university campus with some 5000 students. One vendor is offering us a Cisco solution with a WLC 5508 controller and 69 2x2 MIMO Dual-band/Dual radio APs (Aironet AP 1042 model) The other vendor is offering us an Aruba solution with a 3600 controller and 96 2x2 MIMO dual band BUT single radio APs (Aruba AP93) Both vendors are charging 82.000 US$ (support, 3y service contracts, switches and additional required options all included of course) The Aruba vendor is trying to convince me that 96 single radio APs will give us more connection/users/capacity then the 69 dual radio APs. I have my doubts about that and since it is my core competence-domain I wanted to ask here the opinion of people that have a more profound knowledge and experience in this area. When you talk to vendors it's often hard to get objective information. So try to answer only if you are sure and please mention it if you are affiliated with one of the vendors. I appreciate all useful help and want to thank you in advance for the effort!

    Read the article

  • Migrating SBS 2003 to 2012 standard

    - by AryaW
    My company is currently trying to migrate a Windows Small Business Server 2003 to Windows Server 2012. We know the general procedure, but we want to make sure we aren't going to mess anything up tremendously. Here's the steps we were planning on taking: 1. Uninstall exchange 2. Remove legacy GPO's 3. Demote the domain controller 4. Promote the new server to the primary domain controller. We have no mail servers to worry about. My question is, will the above method work or will we need to make a complete new domain? Thanks!

    Read the article

  • IBM storage ds3400 Cant connect to management using fiber

    - by Eli B
    i have a problem with a DS3400 IBM storage system we bought a few years back. when i try to manage the storage using its IBM storage management i cant find it using automatic detection even though its connected directly using the fiber and i can see the Logical drives connected and working properly. when i tried to connect the two management Ethernet wires and manage the storage directly by entering the IP address manually i am able to connect however after i make several changes to the controller configuration one of the controllers stops responding and i am not able to ping it directly (since you cant make any changes without being connected to both controllers this is a problem) whats more bizarre is that when i change the IP of the controller that doesn't respond it starts working .. i have found some articles over the web explaining stuff about LUN31 being missing and causing similar problems however all my attempts to manually configure it failed . *link to an example http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5075711 in short im trying to get my storage to appear in the storage manager when directly connected using only the fiber cable directly attached. thanks in advance

    Read the article

  • Why does unpartitioned Hitachi HDS5C3020 drive start consuming 50% more power 15 minutes after boot?

    - by Pro Backup
    In a Debian 6.0.6 system there are 74 pieces of 2TB Toshiba DT01ABA200 drives. These drives are identified as Hitachi HDS5C3020BLE630 drives running firmware revision MZ4OAAB0. 64 Drives attached via HP SAS expander cards to an LSI 2008 SAS controller, another 5 drives are connected directly to the mainboard, 4 drives are connected to a Sil based PCI controller and last 1 drive is only powered and has no data cable connected. The controller LSI and Sil card's their onboard BIOS are both disabled and the mpt2sas and sata_sil modules are removed from the Linux debian 2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 x86_64 GNU/Linux kernel. The mpt2sas module is loaded after boot using a modprobe command in /etc/rc.local. These 74 drives are not partitioned, neither formatted and also not mounted. The system consumes: with 0 drives: 70.6 - 70.9 Watt (also 15 minutes after boot); with 74 drives: 330 - 360 Watt, just after boot (is equivalent to 3.5 - 3.9W per drive in idle state); with 74 drives: 420 - 466 Watt, each time in the 15th minute of uptime (is equivalent to 4.7 - 5.3W per drive in idle state). The drive specification lists 4.7W as read/write, and 3.3W as idle power consumption. The increased power consumption is most likely on the 5V line, because after roughly 1 minute an "over current protection" (OCP) of the power supply (PSU) shuts down the power. The used PSU is a single rail model with an OCP of 122A on the 12V line and 55A on the 5V line. Regression: It doesn't matter whether the drive its APM value is set to disabled or 1 (maximum power saving). The operating system records no read/write activity in /proc/diskstats. The values there are identical (28 read, 0 write operations) as immediately after the modprobe operation. Can't test what happens when booting into the mainboard it's BIOS - to exclude any OS intervention - because the Super Micro X8SI6-F mainboard running firmware 06/27/12 has a bug that incorrectly reads a +74.0 C CPU sensor temperature as "High" in BIOS mode, and shuts down the power after 1 minute. What might be causing the drive read/write activity on all drives in the 15th minute after boot and how to prevent it from happening?

    Read the article

  • Problem setting up DL360G5 with scsi RAID

    - by ernelli
    I have a problem with reinstalling OS on a DL360G5. The BIOS [F9] do not detect any disc controllers and the HP SmartSetup did not find any compatible controllers. Inside the server, the two SCSI disks are conncted to a RAID controller using BCM8603 chipset. How is disc contoller supposed to be setup? I have tried to do a full BIOS reset. EDIT At the moment we suspect that the Smart Array controller E200i/412205-001 is broken. Are there any status LED's that indicate failure or success during start up? At the moment all LED's are off.

    Read the article

  • BIND returns serverfail when querying for its authoriative domain

    - by estol
    Hi there Serverfault folks! First of all: sorry about the title, I had some problem coming up with the proper title. I have a little home server set up, for internet sharing, samba, basic http, dlna mediaserver and what not, and I happend to have a domain at hand, so I thought why not direct it to this computer? I have a BIND 9.8.0 installed, and - afaik - configured it properly. For a few days, the public view did not worked, and I really did not cared, since the local view worked. But now suddenly, even the local view fails. If I try to query the nameserver for anything in my domain, it returns the following error: $ nslookup andromeda.dafaces.com ;; Got SERVFAIL reply from ::1, trying next server ;; Got SERVFAIL reply from ::1, trying next server Server: 127.0.0.1 Address: 127.0.0.1#53 ** server can't find andromeda.dafaces.com.dafaces.com: SERVFAIL Also, the public view points to the old ip address of the domain, probably because of the same error. Some information about the system: $ uname -a Linux tressis 2.6.37-ARCH #1 SMP PREEMPT Tue Mar 15 09:21:17 CET 2011 x86_64 AMD Athlon(tm) 64 X2 Dual Core Processor 5000+ AuthenticAMD GNU/Linux $ named -v BIND 9.8.0 And the named.conf file: # cat /etc/named.conf // // /etc/named.conf // include "/etc/rndc.key"; #controls { # inet 127.0.0.1 allow {localhost; } keys { "dnskulcs"; }; #}; options { directory "/var/named"; pid-file "/var/run/named/named.pid"; auth-nxdomain yes; datasize default; // Uncomment these to enable IPv6 connections support // IPv4 will still work: listen-on-v6 { any; }; listen-on { any; }; // Add this for no IPv4: // listen-on { none; }; // Default security settings. // allow-recursion { 127.0.0.1; ::1; 192.168.1.0/24; }; // allow-recursion { any; }; allow-query { any; }; allow-transfer { 127.0.0.1; ::1; 92.243.14.172; 87.98.164.164; 88.191.64.64; }; allow-update { key "dnskulcs"; }; version none; hostname none; server-id none; zone-statistics yes; forwarders { 213.46.246.53; 213.26.246.54; 8.8.8.8; 8.8.4.4; 192.188.242.65; 193.227.196.3; 2001:470:20::2; }; }; view "local" { match-clients { 192.168.1.0/24; 127.0.0.1; ::1; fec0:0:0:ffff::/64; }; recursion yes; zone "localhost" IN { type master; file "localhost.zone"; allow-transfer { any; }; }; zone "0.0.127.in-addr.arpa" IN { type master; file "127.0.0.zone"; allow-transfer { any; }; }; zone "." IN { type hint; file "root.hint"; }; zone "dafaces.com" IN { type master; file "internal/dafaces.com.fw"; allow-update { key "dnskulcs"; }; }; zone "1.168.192.in-addr.arpa" IN { type master; file "internal/dafaces.com.rev"; allow-update { key "dnskulcs"; }; }; }; view "public" { match-clients { any;}; recursion no; zone "dafaces.com" IN { type master; file "external/dafaces.com.fw"; allow-transfer { 87.98.164.164; 195.234.42.1; 88.191.64.64; }; }; }; //zone "example.org" IN { // type slave; // file "example.zone"; // masters { // 192.168.1.100; // }; // allow-query { any; }; // allow-transfer { any; }; //}; logging { channel xfer-log { file "/var/log/named.log"; print-category yes; print-severity yes; print-time yes; severity info; }; category xfer-in { xfer-log; }; category xfer-out { xfer-log; }; category notify { xfer-log; }; }; All help would be highly appreciated! EDIT: Zone files: # cat /var/named/internal/dafaces.com.fw $ORIGIN . $TTL 3600 ; 1 hour dafaces.com IN SOA tressis.dafaces.com. postmaster.dafaces.com. ( 2011032201 ; serial 28800 ; refresh (8 hours) 7200 ; retry (2 hours) 2419200 ; expire (4 weeks) 3600 ; minimum (1 hour) ) NS tressis.dafaces.com. A 192.168.1.1 MX 10 mail.dafaces.com. $ORIGIN _tcp.dafaces.com. _http SRV 0 5 80 www.dafaces.com. _ssh SRV 0 5 22 tressis.dafaces.com. $ORIGIN dafaces.com. acrisius A 192.168.1.230 andromeda A 192.168.1.7 andromeda-win7 CNAME andromeda aspasia A 192.168.1.233 athena A 192.168.1.232 callisto A 192.168.1.102 db A 192.168.1.1 management A 192.168.1.1 ; web management for the router functions haley A 192.168.1.5 hoth A 192.168.1.101 mail A 192.168.1.1 satelite A 192.168.1.20 sony-player A 192.168.1.103 TXT "310f16de2d2712dfc4ae6e5c54f60f828e" torrent A 192.168.1.1 tracker A 192.168.1.1 tressis A 192.168.1.1 www A 192.168.1.1 zeus A 192.168.1.231 and # cat /var/named/external/dafaces.com.fw $ORIGIN . $TTL 3600 dafaces.com IN SOA ns.dafaces.com. postmaster.dafaces.com. ( 2011032405; serial 28800; refresh 7200; retry 2419200; expire 3600; minimum ) NS ns.dafaces.com. NS ns0.xname.org. NS ns1.xname.org. NS ns2.xname.org. A 89.135.129.37 MX 10 mail.dafaces.com. $ORIGIN dafaces.com. ;Szolgaltatasok _ssh._tcp SRV 0 5 22 tressis _http._tcp SRV 0 5 80 www ns A 89.135.129.37 hoth A 89.135.129.37 www A 89.135.129.37 mail A 89.135.129.37 db A 89.135.129.37 torrent A 89.135.129.37 tracker A 89.135.129.37 Edit: Ohh, hell I almost forgot. Since the node is connected to the internet via a residential connection, there is a possibility, that the public ipv4 address will change(but thank god, it is a very rare case), so I daily update the external IP address in the zone file with a shellscript: # cat /etc/cron.daily/dnsupdate #!/bin/sh FILE="/var/named/external/dafaces.com.fw" SERIAL=$(date +%Y%m%d05) PUBLIC_IP=$(ifconfig internet |sed -n "/inet addr:.*255.255.255.255/{s/.*inet addr://; s/ .*//; p}") cat $FILE | sed --posix 's/^.* serial$/\t\t\t\t\t'$SERIAL'; serial/' | sed --posix 's/[0-9]*\.[0-9]*\.[0-9]*\.[0-9]*/'$PUBLIC_IP'/' > /tmp/ujzona mv /tmp/ujzona $FILE /etc/rc.d/named reload

    Read the article

  • Windows XP Home Edition SP3 cant recognise PCMIA SD Card

    - by Pozo
    System Specifications: Laptop : Dell Inspiron 6000 OS: Windows Home Edition SP3 SD Adapter: Hagiwara Smart Media Adapter I inserted the card into the slot, windows xp recognises the device, lists the pcmia controller on the device manager list, an entry appears under the IDE ATA/ATAPI category on the device manager as well. However, the device does not show under my computer and the driver does not get assigned a letter number. I checked the system logs from the device manager and there were no logged errors. Checking the Hagiwara support website, the manufacturer indicates that the adapter driver is the same as the windows xp pcmia controller. Checking Dell's website, no specific drivers were listed for that either. General Search on the web indicates that multiple people face similar problems with their SD cards, yet none actually spell out the route issue that causes this. Please let me know if you have any suggestions for further debugging. Thanks in advance

    Read the article

  • Anyone had any issues getting a disk to start on a Walrus storage sytem?

    - by Peter NUnn
    Hi folks, I'm trying to get a Eucalyptus system up and running and have managed to get the cloud controller and node controller running fine, with an instance running in the cloud system, but without any persistent storage. When I try and create a volume I get euca-create-volume -s 10 -z cluster1 VOLUME vol-5F5D0659 10 creating 2010-05-31T09:10:11.408Z but when I try and see the volume I get euca-describe-volumes VOLUME vol-5F5D0659 10 cluster1 failed 2010-05-31T09:10:11.408Z VOLUME vol-5FE9065E 10 cluster1 failed 2010-05-31T09:02:56.721Z I've dug all over the place, but can't seem to turn up a reason the creation would fail or where to start looking to see what the issue might be. Anyone have any ideas where to even start looking for the answer to this? Ta Peter.

    Read the article

  • MD3200i Slow Performance and Queue Depth

    - by Caleb_S
    Read performance on our SAN is slow under certain workloads. When we compare this to some local storage, we find the local storage performing 2x as fast. The SAN performs well with a high Queue Depth, and poorly with a low queue depth. However, the local storage performs well with a low Queue Depth. I'd like to know the reason for this occurring and find out what the specific limiting factor is in this situation. MD3200i iSCSI SAN ($15,000) 6 x 600GB 15k SAS RAID5 6 x 2TB 7.2k NLS RAID5 XCOPY /j Benchmark: (Slow) 15k Array - 71MB/s (Queue Depth 1) 7.2k Array- 71MB/s (Queue Depth 1) Robycopy /MT:32 Benchmark: (Fast) 15k Array - 171MB/s (Queue Depth ~12) 7.2k Array- 128MB/s (Queue Depth ~12) , , Read Performance on a Local controller is fast under the workload the SAN is slow at. , HighPoint 2230 RAID Controller ($600) 4 x 1TB 7.2k SATA RAID5 XCOPY /j Benchmark: 7.2k Array - 145MB/s (Queue Depth 1) (appears to max out the SATA bus)

    Read the article

  • Initiate a PHP class where class name is a variable

    - by ed209
    I need some help with an error I have not encountered before and can't seem to find anywhere. In a PHP mvc framework (just from a tutorial) I have the following: // Initiate the class $className = 'Controller_' . ucfirst($controller); if (class_exists($className)) { $controller = new $className($this->registry); } $className is showing the correct class name (case is also correct). But when I run it I get this in the apache error log (no php error) [Wed Mar 31 10:34:12 2010] [notice] child pid 987 exit signal Segmentation fault (11) Process id is different on every call. I am running PHP 5.3.0 on os x 10.6. This site seems to work on 5.2.11 on another Mac. Not really sure where to go next to debug it. I guess it could be an apache setting as much as a php bug or a problem with the code... any suggestions on where to look next?

    Read the article

  • SCSI vs SATA? Is SCSI "actually" better?

    - by earlz
    Well, I was talking with a guy about servers the other day. I was a bit shocked whenever I asked him if there was any significant difference between SCSI and SATA and why he always uses SCSI. (note, I'm not sure if by SCSI he meant SAS) He told me that SCSI is always faster and that the drives are always more reliable.. I mean, this seems like a bold statement. He told me something about how SCSI will always be faster than SATA because the OS sends the SCSI (controller?) a request to get a file and it will build the file inside of the SCSI controller, instead of searching all over the disk.. which I do not understand how that would work, so I figure it is BS. SAS and SATA currently have equivalent data rate speeds.. Is there any true backing for his reasoning that SCSI is always faster and more reliable than SATA?

    Read the article

  • Logon Failure: the target account name is incorrect after making a ghost image of a server

    - by cop1152
    I recently replaced a failing SCSI drive in a Windows 2000 server with an IDE drive. I made an image of the SCSI drive and Ghosted it. The purpose of the machine was to give out DHCP at one location and host a couple of files. When I restarted the machine with the new drive, DHCP appears to be working fine, but I cannot get to any of the shares. Instead, I get the following message when attempting to navigate using Explorer. Logon Failure: the target account name is incorrect It appears that this machine is not communicating with the main domain controller. Changes to user accounts (performed on the domain controller) are not replicated on this machine.

    Read the article

  • Artefacts during HDV capture

    - by Jakub Konecki
    When I try to capture HDV video stream from a Canon HV20 camera to a Dell Studio 1558 (Intel i7 720qm) laptop running Win 7 Home Premium x64, the image appears with a very annoying noise - it contains block artefacts. Something is wrong with the Fire Wire controller (Ricoh 1304 OHCI host controller, build-in). Tried changing the driver to legacy one to no avail. This does not happen with DV stream. I'm using a Belkin cable. The capture works OK on another machine.

    Read the article

< Previous Page | 376 377 378 379 380 381 382 383 384 385 386 387  | Next Page >