Search Results

Search found 13047 results on 522 pages for 'np hard'.

Page 407/522 | < Previous Page | 403 404 405 406 407 408 409 410 411 412 413 414  | Next Page >

  • Error when attempting to do a differential or incremental backup of Exchange using ntbackup

    - by voon
    Hi folks, We're running Small Business Server 2003 here. I was reviewing our backup procedures lately and noticed in the ntbackup logs that the differential backups of Exchange were failing with the error: (SERVERNAME)\Microsoft Information Store\First Storage Group is not a valid drive, or you do not have access. A quick search of google found this MS KB article: http://support.microsoft.com/kb/555613 However, both of the suggested fixes don't to apply to our problem. First solution is to make sure the backup media is formatted and has adequate space. Well, our backup target is a 1 TB external hard drive with about 600 gigs of free space. (A full backup of our Exchange DB is currently around 5 GB) The second suggested fix is to "perform a full backup before trying to do incremental". And again, that can't it because we are doing full backups twice a week. There are no errors in the application log, just entries for ntbackup starting and ending. I've also tested doing an differential & incremental backup onto the server's internal drive, which unsurprising still did not work. I could get around this problem by always doing a full backup of Exchange but I kind of like the idea of being space efficient with doing differential backups. Anyone got any ideas?

    Read the article

  • Server Bash Line Wrapping Over Text & In Wrong Place

    - by Pez Cuckow
    This is quite a hard problem to explain, when connecting to one of my servers using the bash shell, under any user the line wrapping is broken and has all sorts of problems. Once of which I detail in screenshots below: Other problems I experience include nano getting very confused about which line and or letter I am on, as shown by typing the same message into nano: These problems only occur when connecting as I previously mentioned to one of my servers which runs CentOs. Do you know why this is occurring and what I can do to fix it? On other servers the message works fine! Thanks for your time, Output of requested commands: Server that doesn't work properly: Working server: Could it perhaps be the custom prompt on the non working server? In .bashrc PS1='\e[1;32m\u@\h\e[m:\e[1;34m\w\e[m$ ' Commenting this out appeared to resolve the problem. Google says line wrapping errors can occur if you don't conform to these rules use the \[ escape to begin a sequence of non-printing characters, and the \] escape to signal the end of such a sequence I am not sure where this would fit in on my prompt?

    Read the article

  • Give back full control to a user on a disk from another computer

    - by Foghorn
    I have my friend's hard drive mounted externally. After messing with the permissions with TAKEOWN so I could fix some viruses, I have full control over their drive. The problem is, now it's stuck in a "autochk not found" reboot sequence. I think the problem is that the boot sector is invisible to the drive now. So my question is, How can I use icacls to give back the full ownership, when the user I am giving it to is not on my machine? I ran the TAKEOWN command from my windows 7 laptop, their machine is a windows xp Professional with three partitions, I only altered the one that has the boot sector. Here is the permissions that icacls shows: (Where my computer is %System% my username is ME, and the drive is E:\ C:\Users\ME icacls E:\* E:\$RECYCLE.BIN %System%\ME:(OI)(CI)(F) Mandatory Label\Low Mandatory Level:(OI)(CI)(IO)(NW) E:\ALLDATAW %System%\ME:(I)(OI)(CI)(F) E:\alrt_200.data %System%\ME:(OI)(CI)(F) E:\AUTOEXEC.BAT %System%\ME:(OI)(CI)(F) E:\AZ Commercial %System%\ME:(I)(OI)(CI)(F) E:\boot.ini %System%\ME:(OI)(CI)(F) E:\Config.Msi %System%\ME:(I)(OI)(CI)(F) E:\CONFIG.SYS %System%\ME:(OI)(CI)(F) E:\Documents and Settings %System%\ME:(I)(OI)(CI)(F) E:\IO.SYS %System%\ME:(OI)(CI)(F) E:\Mitchell1 %System%\ME:(I)(OI)(CI)(F) E:\MSDOS.SYS %System%\ME:(OI)(CI)(F) E:\MSOCache %System%\ME:(I)(OI)(CI)(F) E:\NTDClient.log %System%\ME:(OI)(CI)(F) E:\NTDETECT.COM %System%\ME:(OI)(CI)(F) E:\ntldr %System%\ME:(OI)(CI)(F) E:\pagefile.sys %System%\ME:(OI)(CI)(F) E:\Program Files %System%\ME:(I)(OI)(CI)(F) E:\RECYCLER %System%\ME:(I)(OI)(CI)(F) E:\RHDSetup.log %System%\ME:(OI)(CI)(F) E:\System Volume Information %System%\ME:(I)(OI)(CI)(F) E:\WINDOWS %System%\ME:(I)(OI)(CI)(F) Successfully processed 22 files; Failed processing 0 files C:\Users\ME

    Read the article

  • What parts should I get for an ASRock x58 Extreme motherboard

    - by Brad Gilbert
    I just received an ASRock x58 Extreme motherboard, for my post on this question. It was a 2009 Tom's Hardware recommended buy. It is a Core i7 motherboard, with an X58 Express Chipset. It uses DDR3 RAM. What I want to know is, what parts should I get to finish it off. I'm looking for some good bargains, because of a lack of funds. The most taxing game I will probably play on it is OpenTTD. The only parts I currently have that are compatible: A Dynex 400W power supply. It appears to be an ATX 2.1 power supply, with the addition of a -5 rail. Apparently designed to be compatible with most ATX-style motherboards. Several PCI add-in cards. Mostly 10/100 Network cards Some sound cards Some video cards with a VGA connector Plenty of PATA drives. 8 GB - 80 GB Hard-drives A dozen or-so CD-ROM drives, only a handful of them are CD-RW drives. One DVD-ROM drive I have one LCD, with a 15 pin VGA connector, which I salvaged from the dump. The only thing wrong with it was some dead capacitors. It also has a stuck pixel.

    Read the article

  • Spurious alleged file corruption on Windows 7

    - by Johannes Rössel
    Recently my Laptop sometimes warns about corrupted files on the hard drive (Samsung SSD PB22-JS3 TM). This has only happened so far when updating (or checking out) an SVN repository with either TortoiseSVN or the command line Subversion client. The fun thing is that the corrupted file has always been a .svn directory (although the directory entry may contain files in that directory too, if they're small enough?—?which should be the case with SVN). However, when looking into the warned-about directory I notice nothing strange or unusual and don't get any more warnings about it and another try (SVN stops updating once that error occurs?—?TortoiseSVN even with an appropriate error message) of updating the working copy works (well, mostly; sometimes it does it again, albeit with a different directory). Since the laptop is only a few months old I doubt the SSD is failing already—five months of normal usage shouldn't be too surprising. Also it (so far) occurred only with SVN updates on a large repository. Maybe that's too many writes in a short time and some part between the software and the hardware doesn't quite catch up fast enough or so?—?I don't know enough about this to actually make an informed guess here. Anyone knows what's up here? ETA: Note to add: I've run chkdsk (it seems to schedule itself anyway when this happens) and it didn't find anything out of the ordinary.

    Read the article

  • Error occurs when Win 7 opens

    - by user1708748
    I have an HP customized laptop barely a week old. Since yesterday it has given me an error message while opening Windows- every time. it gives error code (0x40000015) refers to an exception at location (0x0033fa4d). I have 64 bit Win 7 and had been transferring files. And installing programs. 8 GB Ram 650 gb hard drive. Not sure which program caused this. Q's that I've seen with this error code all say it occurs while shutting down. A search re. error code told me to use a removal tool. When I downloaded the tool,I got a message saying it is not compatible with Windows 7. Is that really possible? Search re. location code yielded nothing I am an intermediate user. I can restore to an earlier time but I don't know which program might do this again.

    Read the article

  • Permissions on mac for itunes library with multiple users - idea

    - by John
    I currently have a lot of music on an external drive and my itunes set up from there. However, periodically, when the external drive isn't connected, itunes will default back to the library location of my home directory user path. I don't want to mess with an external drive, as my mac HD is large enough to house the music collection. However, I have 4 family members - all with their own logins - using this same gob of music. I don't want 4 copies of the library, only one with all libraries referencing it. So, what I want to do is: 1 - move all music files to a shared directory at /Macintosh HD/users/music. I created this directory and adjusted permissions, so all four users can read and write to this directory. 2 - get all four accounts to reference this library instead of the external or local home locations I am hoping I can just check the box to keep library organized in my account, which is the admin and let itunes move it all. Then delete current libraries for each account and re-add from the new shared location. Will the itunes organization process cause permissions issues either by setting permissions to all the files access to my account only or write permissions or any other 'gotcha'? I am having a hard time coming up with a smooth solution that won't break everything and cause me to have mega duplicates or access issues. I would prefer not to do any xml library file editing if possible. Am I dreaming? Thanks for help.

    Read the article

  • Windows Server 2008 R2 install reboots unexpectedly during "Completing installation" phase

    - by knda
    I am attempting to install Windows Server 2008 R2 onto a Cisco UCS C201 M2 rack mounted server but am having major difficulties and wondering if anyone has some insight or items they could recommend for me to look at to get this one resolved. Installation is being attempted via the Cisco remote console (using CIMC's Virtual dvd-rom).. following the first phase of Setup where the installation files are copied to the target hard drive, then a reboot occurs to load Setup from the HDD, mid-way in the "Completing Installation" phase the system then reboots unexpectedly. System configuration Cisco UCS C201 M2 (2RU rack mounted server) 16GB RAM, 2x 73GB 15K SAS, 4x 300GB 10k SAS Add-on cards - Intel quad-port GigE card (no fibre channel cards) Storage - LSI MegaRAID SAS 9261-8i. onboard SATA is disabled (no SATA drives connected) KVM - Belkin No physical DVD-ROM.. :( I have... Run memtest86+, no RAM faults Disabled/enabled SATA support (BIOS) Attempted install from USB DVD-ROM, no effect Attempted unattended install scripted via Cisco Configuration Manager DVD provided Removed Belkin KVM in case that was causing drama Discovered that the Cisco website is "awesome" for searching for PDFs/Drivers cough, reverted back to Google Downloaded latest LSI drivers from LSI's site and used during Server 2008 install checked Windows ISO against checksum's from MS site checked Windows ISO by using it for an install in a VM Running out of ways to troubleshoot this as I am not sure how to enable any sort of 'verbose' mode during the setup process. Next step I have planned is to remove the Intel NIC and try the installation again.. Edit: Problem was the "Cisco INTEL QUAD PT GBE" (1000/PT) .. will have to see if this card is faulty or if it's just drivers.. thanks for the help.

    Read the article

  • Matlab computations done over Apple Filing Protocol (AFP) depend on POSIX permissions, ignores ACLs

    - by flumignan
    I'm a system administrator and have never used Matlab, so forgive my general ignorance of the program. My users have encountered problems when executing scripted Matlab actions over AFP to a Mac OS X Server 10.6.7 where the access control list (ACL) should allow actions, but the POSIX-style permissions disallow the activity. It seems as if Matlab, run locally on the Mac workstations on datasets on the remote server, ignores the ACLs entirely. This is the only application I've ever seen behave this way. The server's filesystem is HFS+J and all other activity is performing as expected. These users cannot use CIFS because of our integration with external directory systems. In this example, the directory bxdata, the members of the group cibturner should be able to modify the files. Indeed, they can using any other method except via Matlab scripts. When the Matlab script hits these files, the POSIX permissions of 644 disallow modification. It's as if the ACLs are irrelevant. [root@cib 16:00:24 /14181.2_5sM]# ls -leh@ bxdata/ total 128 -rw-r--r--+ 1 kel32 staff 18K Feb 15 09:31 TS-5sMath030708-21073-1.edat 0: group:cibturner inherited allow read,write,execute,append,readattr,writeattr,readextattr,writeextattr,readsecurity,writesecurity,chown 1: group:cibsrlocaladmins inherited allow read,write,execute,append,readattr,writeattr,readextattr,writeextattr,readsecurity,writesecurity,chown 2: group:crcservergroup inherited allow read,write,execute,append,readattr,writeattr,readextattr,writeextattr,readsecurity,writesecurity,chown -rw-r--r--+ 1 kel32 staff 25K Feb 15 09:31 TS-5sMath030708-21073-1.txt 0: group:cibturner inherited allow read,write,execute,append,readattr,writeattr,readextattr,writeextattr,readsecurity,writesecurity,chown 1: group:cibsrlocaladmins inherited allow read,write,execute,append,readattr,writeattr,readextattr,writeextattr,readsecurity,writesecurity,chown 2: group:crcservergroup inherited allow read,write,execute,append,readattr,writeattr,readextattr,writeextattr,readsecurity,writesecurity,chown Because this server has HIPAA data, security is critical. We are not using networked home directories or SAN technology. The MatLab program is run on the user's hard drive; access is granted via Kerberized AFP.

    Read the article

  • "The directory name is invalid" when trying to install drivers in Windows 7 via Device Manager

    - by Luke
    First off, this computer is not mine, it's a customer's system. Having said that... The hard drive was moved to a new motherboard, CPU, RAM combo, and booted up fine. Customer puts in driver CD, drivers won't load. He brings it into me. Under Device Manager for Windows 7 x64, I see lots of PCI to PCI bridge, one SMBus Controller, and about 20 Unknown Devices. Greeeeeat... So I start with the SMBus driver directly from the Asus website for the motherboard (P8H77-M Pro). If I install from the setup program, it tells me to reboot, then it starts the install. It gets half way through the setup, then fails (An unknown error occurred. Setup will exit). When I try to point to the folder from Device Manager, it starts copying files for the driver, even presents me with the proper name of the device, but says that an error has occurred there as well: The directory name is invalid. Doing some Googling, I saw that many people had this issue with Vista. K, Vista and 7 are similar, maybe the solutions are the same... But they aren't. I tried: Copying the entire driver folder and setup utility to the Program Files folder and running it / selecting it in DM Downloading another set of drivers in case this one is corrupt Disabling UAC Deleting and recreating the %WINDIR%\TEMP folder Removing all references to previous hardware that I could find, even in Device Manager's hidden mode So far, nothing has worked. A wipe and reload will be out of the question

    Read the article

  • Intel Atom overheating in ASUS EEE Box 1501P

    - by Sergey L.
    I have had an ASUS EEE Box 1501P for just a little bit over a year. Of course it breaks 2 months after the warranty runs out. http://www.asus.com/Eee/EeeBox_PC/EeeBox_PC_EB1501P/ I have been using the box as a Home Media Center. Running mostly 24/7 often pausing a video overnight. Since last week the fan started running extremely loud. After some digging I found that the Intel Atom CPU in it is overheating and the built-in sensor is reporting temperatures way over 105°C. This got me worried, so I took the unit apart. Completely vacuumed the heat sink, oiled the fan, but the unit is still showing the same behaviour. After turning it on and just observing the hardware monitor in the BIOS the temperature slowly rises from 40°C to over 95°C in appx 5 min. I am running the newest BIOS and a lightweight Linux OPENELEC OS with XBMC on it. Now I am wondering if it could be a faulty heat sensor in the Atom. Recommended running temperature is up to 85°C, but I have not detected any performance hits when running at the above mentioned 105°C and there seem to be no software faults. How can an Atom with an attached heat sink and a fan running at full capacity even get this hot in the first place at 0 load? Aren't those things designed to generate virtually no heat? Could it be a faulty heat sensor? What shall I try to fix this? I would prefer not to damage the CPU, since it is hard fused into the motherboard and cannot be replaced. I could remove the heat pipe/heat sink, but it is getting hot, so heat is properly transferring from the CPU to the heat pipe, the fan is running at full capacity, is recently oiled and warm air is making it out of the exhaust. Edit: One more note: The North-bridge (or whatever it is called nowadays) is on the same heat pipe.

    Read the article

  • Need troubleshooting advice for intermittent dns problems with requests on isp nameservers

    - by Mnebuerquo
    I've been having some intermittent dns problems with a web server, where certain isp's dns servers don't have my hostnames in cache and fail to look them up. At the same time, queries to opendns for those hostnames resolve correctly. It's intermittent, and it always works fine for me, so it's hard to identify the problem when someone reports connectivity problems to my site. My website is on a server running linux with Plesk. My dns records are configured with plesk (so my server is its own dns master). Domain name is registered with godaddy. I'm not real knowledgeable about dns, so I don't really know how to begin with troubleshooting. I've started learning to use dig, but while I can read the manpage to learn the syntax, I don't really know what questions to ask. Since the problem is intermittent I haven't been able to really catalog many symptoms. Symptoms I have observed: Certain people repeatedly reported intermittent problems connecting to my website. This was only from certain networks. (Ex: One guy could connect reliably from his office but not his home.) Sometimes I notice my browser taking a long time looking up the hostname for my site (Firefox shows a message in the status bar at the bottom). For me this is in the ten second range. ssh connections from anywhere to my server take a long time to connect but then seem to work fine once connected. So hopefully the folks on serverfault can point me to a good beginner tutorial for understanding dns, and suggest troubleshooting questions to ask next time one of my users reports connectivity problems.

    Read the article

  • Managing a test iSCSI target server

    - by dyasny
    Hi all, I am using a RHEL server with a few hard drives, and tgtd as the iscsi target software. I a looking for a way to allocate and deallocate space and targets with that space, without restarting my system, or harming other LUNs. Currently, all my HDDs are PVs in a single VG, and I lvcreate/lvremove as required, and then export the allocated LVs using a tgt script: usr/sbin/tgtadm --lld iscsi --op new --mode target --tid=1 --targetname iqn.2001-04.com.lab.gss:300gb /usr/sbin/tgtadm --lld iscsi --op new --mode logicalunit --tid 1 --lun 1 -b /dev/mapper/iscsi_vg-iscsi_300Gb /usr/sbin/tgtadm --lld iscsi --op bind --mode target --tid 1 -I ALL /usr/sbin/tgtadm --lld iscsi --op new --mode target --tid=2 --targetname iqn.2001-04.com.lab.gss:200gb /usr/sbin/tgtadm --lld iscsi --op new --mode logicalunit --tid 2 --lun 1 -b /dev/mapper/iscsi_vg-iscsi_200Gb /usr/sbin/tgtadm --lld iscsi --op bind --mode target --tid 2 -I ALL /usr/sbin/tgtadm --lld iscsi --op new --mode target --tid=3 --targetname iqn.2001-04.com.lab.gss:100gb /usr/sbin/tgtadm --lld iscsi --op new --mode logicalunit --tid 3 --lun 1 -b /dev/mapper/iscsi_vg-iscsi_100Gb /usr/sbin/tgtadm --lld iscsi --op bind --mode target --tid 3 -I ALL tgtadm --mode target --op show So in order to remove a LUN, I stop the tgtd service, lvremove the lv, and remove the entry from the iscsi target script When I add a lun, I run lvcreate, and then add an entry to the script and run it. This is not quite optimal, since restarting the service is a bad idea while other LUNs are busy, so I am looking for a more scalable and safer way. Thanks

    Read the article

  • How to "swap in" again memory from page file to physical memory in Windows at once (like linux swap-off)

    - by Arnout
    Is there a way to swap back in (to put back all the memory data that was put into the page file (or swap, whatever you prefer)) memory on a windows PC? On linux, one can easily do this with the swapoff /dev/sdaX, where X is the swap partition. On windows, it seems to ask me to reboot each time.. The reason I'd like to do this, is that, even though swapping out the data to the swap file allows me to play a resource-hungry game fully in physical ram, when I stop the game, all the rest of my programs run slow. This is or course normal; all the programs were pushed into the page file because my RAM was too small, and all memory access to those programs after gaming bumps into hard page faults, with major delays and some frustration as a consequence. However, that frustration could easily be avoided, by simply allowing the PC to copy all data back into the physical memory for a minute or so, and then resume working on a fast working PC! (rather than having to endure the slowness -while- working) Thanks in advance for any advice on this! Kind regards

    Read the article

  • WinPcap/Wireshark install: where is packet.ddl?

    - by Annonomus Penguin
    I have Wireshark installed, and I'm getting this error: The NPF driver isn't running. You may have trouble capturing or listing interfaces. I realize this is something to do with WinPcap. It's not in control panel, as the FAQ states it should be. I've tried installing it, and it says that there is a previous version installed. This leaves me to believe this is the problem: To be absolutely sure that WinPcap has been installed, please look at your system folder: you should find files called packet.* and wpcap.dll. Please check the file dates: these should be compatible with the WinPcap release dates. We've had reports of trojans or other malware that silently install the WinPcap driver, NPF.sys. If you've been infected by them, you'll probably see the driver file in Windows\System32\Drivers, but no entries in the "Add or Remove Programs" applet and no dlls. I've searched my hard drive, but the only path is this: C:\Windows\SysWOW64\packet.dll Is this the file they are talking about? Should I delete this file? I'm not quite sure, so I thought I'd verify that this file is the right one.

    Read the article

  • Lenvo B450 won't boot on battery only?

    - by Mywiki Witwiki
    We bought a Lenovo B450 laptop almost a year ago. It comes with a NVIDIA GEFORCE with CUDA graphics and so the battery life is terrible. It will only last 1:30 hours max. We try to run it on battery as much as possible but because the battery life is short sometimes we can't notice that the battery is so low until the computer blacks out. Because of the short battery life, the laptop is always plugged on AC power. One night the computer froze. Because it was already late, I just reset the laptop my pressing the power button for 10 seconds. The laptop shut off but I did not bother restarting it. The next morning, the laptop won't turn on on battery only. It will only turn on on AC power. The computer instantly shuts down(improperly) once the adapter is removed. But the battery was at 100% then. Now it is slowly losing charge (currently at 74%). The battery indicator says, "Plugged in, not charging". I want to bring the laptop to school but I can't because it won't be portable at all. Just to summarize it all: 1) The laptop suffered some blackouts already. 2) The laptop was on AC power most of the time. 3) When the computer froze, it was reset (hard shutdown). 4) The laptop won't boot with battery only since then. 5) The laptop will shutdown instantly when AC adapter is removed. 6) The battery won't charge and is gradually losing charge. ======================= UPDATE ============================= We got the battery replaced. Unfortunately, it delivers only 2 hours max of power.

    Read the article

  • script calling script as other user

    - by viktor tron
    Using CentOs, I want to run a script as user 'training' as a system service. I use daemontools to monitor the process, which needs a launcher script that is run as root: : #!/bin/bash exec >> /var/log/training_service.log 2>&1 setuidgid training training_command This last line is not good enough since for training_command, we need environment for training user to be set. : su - training -c 'training_command' gives 'standard in must be tty' as su making sure tty is present to potentially accept password. I know I could make this disappear by modifying /etc/sudoers a la Bash & 'su' script giving an error "standard in must be a tty" but i am reluctant and unsure of consequences. : runuser - training -c 'training_command' gives runuser: cannot set groups: Connection refused. I found no sense or resolution to this message. I am stuck. Is this something so hard to achieve? I appreciate all insight and guidance to best practice.

    Read the article

  • How to change controller numbering/enumeration in Solaris 10?

    - by Jim
    After moving a Solaris 10 server to a new machine, the rpool disk is now c1t0d0. We have some third party applications hard coded for c0t0d0. How can I change the controller enumeration on this machine? There is no longer a c0. I've tried rebuilding the /etc/path_to_inst, but the instance numbers don't seem to match up with the controller numbers. Also, it's not clear if i86pc platforms use this file. I've tried devfsadm -C to clear the dangling links, but I'm not sure how to cause devfsadm to start numbering from 0 again (or force certain devices in the tree to a specific controller number). Next I am going to try to create the symlinks manually in /dev/dsk and rdsk to point to the correct /devices. I feel like I am going way off path here. Any suggestions? Thanks Update: This is on virtual ESXi hardware with an additional pass-through HBA. There is no controller 0 on the machine, that is for sure. devfsadm -C cleans up all the c0 device symlinks but keeps the already linked controllers at their current ids.

    Read the article

  • Why are folders disappearing in Windows XP?

    - by XenoFoxx
    I am researching a problem for a friend, and unfortunatly do not have direct access to his computer. I've tried to gather as much information as possible and I have researched it on various websites. I've not found anyone having the same problem my friend is having. So here goes: He has a media server in his home running Microsoft Windows XP. It has 3 drives, 1 for the OS and 2 for mass storage. Not long ago he went to access one of the mass storage media drives and it was empty, except for a single folder. His first assumption was that his roommate had deleted everything on the drive (excluding the remaining folder). He then checked the properties of the drive and it was still saying that the hard drive was nearly full. I told him to check the recycling bin, thinking that whoever deleted them didn't clear them from recycling and that they were still taking up space on the drive. My friend said the recycling bin was empty. So we have a drive that the Windows file management system says is empty (again except for the remaining folder), but the properties of the drive say it's mostly full. Now it gets weirder My friend tried to create a new folder on this drive and it auto-named itself "New Folder(1)" which means that it recognizes there is already a "New Folder" in that directory. He tried to rename it to a name that he KNEW was there previsouly, and Windows wouldn't allow it because it was a duplicate folder name. SO now it seems the folders are there, but not displaying in Windows Explorer. Both of us have no idea why this is occuring, why the folders vanished, why the one remaining folder didn't vanish, or how to make them visable again. Anyone else ever experience this? I can get more details if needed.

    Read the article

  • Linux Mint 13 is not booting on dual boot computer

    - by Brian
    thanks in advance for your time. I have 2 hard drives in my computer a 300 GB drive which is my primary drive for windows 7 and a 1.5 TB drive that I'd used for storage. When I got it I partitioned 500 GB for use in Linux. So, I created a bootable USB and clicked the "Install by Current Operating System" option from Mint. It installed it to the free 500 GB like I'd hoped it would. Now, I can't get it to boot though. I've tried using EasyBCD to create the boot entry and it hangs on a black screen. Thanks. EDIT @ Ryhuk It presents a menu with two options 1) Windows and 2) Mint. This was a menu I created with easyBCD. When I select option 1 it boots to windows fine. When I select option 2 it hangs on a black screen with just a white bar flashing (Can't remember what its called, it marks the current cursor location on a text field) and won't respond to any key presses but alt ctrl del.

    Read the article

  • Nvidia GTS 360M in Asus laptop shuts off when gaming on external display

    - by mr odus
    I have had this problem on my Asus G51j Intel I5, Nvidia GTS360M graphics card. Just updated the drivers to latest off Nvidias site. Most games I play, If I hook it up through an external monitor(this happens whether it's HDMI or VGA). The laptop hard shuts down after about 20 minutes, give or take. This tends to happen on more graphically intense games like Call of dutys, bioshock. I'm running Windows 7, latest nvidia drivers. Games work fine on my laptops screen, and Movies, general computing work fine on the external displays. The laptop always sits on a cooling pad and the latest time was in front of my AC unit, I ran heatfan or whatever the heat tracking software was, and my temperatures were normal through a shut down. This has been happening for the life of the laptop. I dont play very many games, and even fewer on an external monitor, so this issue doesnt come up much Is it possible I have a faulty graphics card? Is there anything else I can try?

    Read the article

  • Google Desktop Search problems - unable to disable indexing and no index status page

    - by Howiecamp
    I've been running Google Desktop (I've used both the regular and Enterprise versions) without issues on my Windows 7 64-bit PC for a long time with no issues. I just paved my PC and reinstalled Google Desktop (regular edition). Initially, I want to use it only for the CTRL-CTRL launcher capability - I don't want it to do any indexing. So I unchecked all the items in the configuration dialog as well as excluded c:. Despite this, it is indexing all the content on my hard drive as well as Outlook email, etc. In my previous installations I had the same options set and they worked properly. The other problem I have is that when you right-click on the Google Desktop system tray icon, there used to be an option for "Index Status" which showed you the percentage complete the index creation process was, as well as an option to clear and rebuild the index. Those are no longer there. I uninstalled the regular edition and installed the Enterprise Edition, but same problems. Any ideas?

    Read the article

  • Apache process consuming all memory on the server

    - by jemmille
    I have an apache process that suddenly appears on a particular server. When it shows up it starts consuming memory at a very rapid rate, then moves on to all the swap. In all it consumes about 11GB (including swap) of memory and the server eventually becomes unresponsive. The load on the server is under 1 at all other times. The process runs as nobody and I am having a hard time tracking down the source. If i run an strace on the process and all it did was continuously dump out mprotect over and over again If i run lsof -p <pid>, I get this, but only sometimes: httpd 19229 nobody 152u IPv4 175050 crawl-66-249-67-216.googlebot.com:62336 (CLOSE_WAIT) httpd 19229 nobody 153u IPv4 179104 crawl-66-249-71-167.googlebot.com:58012 (ESTABLISHED) As long as I catch it, I can kill the process and the server almost immediately stabilizes. I have on site on the server that is getting a few thousand hits a a day that I think might be the source, but I still can't find the exact reason. Also, this is a cPanel server and I have upcp'd the server, rebuilt apache with easy apache, and rebuilt httpd.conf. It is not spawing any related processes, meaning I can find any php, mysql, cgi, etc. processes that relate to this process. It's just a loner process that balloons fast and consumes ever last MB of memory. This is on a XenServer 5.6 based VM. No other servers in the cluster are having this issue.

    Read the article

  • Ubuntu 12.04 froze during update, won't boot

    - by Cichol
    I've recently installed Ubuntu 12.04 on my laptop, and every time i tried to update it, it would freeze for a few seconds, and tell me that the updates could not be downloaded. After many, many tries I managed to get them downloaded, but then in the middle of installing them, it froze. Completely. No mouse movement, no blinking lights, no nothing. After a few hours of letting it sit there, I finally hit the power button to do a hard reset, and now when I select Ubuntu on the boot screen (Dual-boot with Windows 7), I get a blank purple screen, and then nothing. Another freeze. I've tried getting into the console, but no command I input has any visible effect. I have a ton of music stored on the partition it's in, so I'd really rather not have to reinstall. My specs, to the best of my knowledge: Clevo Corp model B7130 (Sager custom) CPU: Intel Core i5 @ 2.53gHz (4 CPUs) Graphics Card: Nvidia GeForce 425m 4096 MB RAM Drivers: Whatever comes with the download of 12.04. As a side-note, I installed Ubuntu via the Windows Installer program (wubi). Does that make a difference?

    Read the article

  • DIR $file "File Not Found" vs DIR $filedir shows it....not permissions, not USB

    - by Kev
    I was having this problem before on a USB drive, but now it's happening on my main RAID5-backed hard disk: 2013-10-17 9:37 C:\>dir "C:\Shares\Shared\Reference\Safety Management System\Vid eo CD\AutoPlay\Docs\Manuel*" Volume in drive C has no label. Volume Serial Number is 3C18-E114 Directory of C:\Shares\Shared\Reference\Safety Management System\Video CD\AutoP lay\Docs 2003-09-09 11:29 PM 1,056,768 Manuel d'intervention d'urgence MFC.doc 2004-06-20 10:36 PM 139,849 Manuel d'intervention d'urgence MFC.pdf 2 File(s) 1,196,617 bytes 0 Dir(s) 196,068,691,968 bytes free 2013-10-17 9:38 C:\>dir "C:\Shares\Shared\Reference\Safety Management System\Vid eo CD\AutoPlay\Docs\Manuel d'intervention d'urgence MFC.doc" Volume in drive C has no label. Volume Serial Number is 3C18-E114 Directory of C:\Shares\Shared\Reference\Safety Management System\Video CD\AutoP lay\Docs File Not Found 2013-10-17 9:38 C:\> This is from a Command Prompt window where I went to Properties and told it I wanted to modify who it ran as. I opened it, had it run as me with the "restricted access" unchecked, then ran the above. The file in question has the following ACLs: Administrators, SYSTEM, and OurCompanyUsers. All three have full control of everything. Nobody has any Deny bits set. I am a member of Administrators. So I don't believe it's a permissions issue. It's not a USB drive, so this time there is no question of USB hardware. Windows Server 2003 Standard Edition SP2. What does this mean? Is this more likely a hardware or software problem?

    Read the article

< Previous Page | 403 404 405 406 407 408 409 410 411 412 413 414  | Next Page >