Search Results

Search found 13355 results on 535 pages for 'applescript studio'.

Page 436/535 | < Previous Page | 432 433 434 435 436 437 438 439 440 441 442 443  | Next Page >

  • Unable to cast object of type 'System.Object[]' to type 'System.String[]'

    - by salvationishere
    I am developing a C# VS 2008 / SQL Server website application. I am a newbie to ASP.NET. I am getting the above error, however, on the last line of the following code. Can you give me advice on how to fix this? This compiles correctly, but I encounter this error after running it. DataTable dt; Hashtable ht; string[] SingleRow; ... SqlConnection conn2 = new SqlConnection(connString); SqlCommand cmd = conn2.CreateCommand(); cmd.CommandText = "dbo.AppendDataCT"; cmd.Connection = conn2; SingleRow = (string[])dt.Rows[1].ItemArray; My error: System.InvalidCastException was caught Message="Unable to cast object of type 'System.Object[]' to type 'System.String[]'." Source="App_Code.g68pyuml" StackTrace: at ADONET_namespace.ADONET_methods.AppendDataCT(DataTable dt, Hashtable ht) in c:\Documents and Settings\Admin\My Documents\Visual Studio 2008\WebSites\Jerry\App_Code\ADONET methods.cs:line 88 InnerException:

    Read the article

  • AnkhSVN: moving a project to another repo

    - by pcampbell
    My task is to move this VS solution and projects to another SVN server. I'm working with Visual Studio 2010 RC1 and AnkhSVN 2.1.7819.... Currently the files are all bound to a repo at C:\Repositories\foo. I'd like to move it to http://someSite/svn/foo I'm presented with this error message: Repository UUID '152c39db-5799-4234-85f2-074004a6fcad' doesn't match expected UUID '6c83444d-7f93-d64a-b0a0-23283495cf17' Questions How can I avoid this message in AnkhSVN? Are there better solutions for moving the source into a repo on the new target? How can I get Ankh to 'forget' that repo at C:\Repositories\ forever?

    Read the article

  • How do you fix TSD02016 error in Database

    - by Keith Sirmons
    Howdy, I have a database I am using the Visual Studio 2010 Database Project tool vsdbcmd.exe to create a schema from. vsdbcmd /a:Import /dsp:Sql /model:"Database" /cs:"Server=SqlServer; Initial Catalog=DatabaseName; Integrated Security=SSPI;" The tool is reporting an error: Error TSD02016, Gen-259 (12,50) The column name is not valid. No table name was specified. How would I go about pinpointing where this error is originating? I have found one resource on the internet (http://social.msdn.microsoft.com....) that points to a possibility of a keyword used incorrectly, but the error messages are not the same. What is Gen-259? Thank you, Keith

    Read the article

  • Which version of Windows 7 for .NET Developers

    - by Dkong
    Hi, I'm looking to upgrade my laptop from Windows Vista to Windows 7. As a .NET developer I'm not interested in developing Windows 7 components at this stage, but was curious which version would suffice to Install Visual Studio/SQL Server and do some web development testing against the local instance of IIS. I don't care too much about the superfluous features of any Windows 7 editions, I just need to know which one will keep me right for running apps and writing some code. Also, does Windows 7 force the "run as administrator" against VS? Any recommendations?

    Read the article

  • Change Ssms2008 default setting on installation

    - by CziX
    Hey, I am currently developing a vbs script, which installs SQL server 2008 + SP1. After the install I want to change the default settings in the Ssms, such as "Prevent saving changes that require table recreation" and such on. I can't figure out, where Ssms hides its settings. Currently I am looking at 1) My Documents\SQL Server Management Studio\ 2) HKCU\Software\Microsoft\Microsoft SQL Server\100\Tools\Shell\Profile But whenever I change a "setting" in the vssettings-file in 1), Ssms thinks it is first time it runs, and overwrite. How can I change the Ssms setting manual, without doing it from the Ssms itself?

    Read the article

  • Keyboard Simulation not working with Keyboard hook for modifier keys

    - by Eduardo Wada
    I have a piece of software that is being used to simulate a certain device on a touchscreen, this device already runs an application that receives keyboard input from the device. My software (reffered to as simulator) displays a virtual keyboard and runs the application. Thus, the simulator sends keys with input simulator: http://inputsimulator.codeplex.com/ And the applciation listens to keys with the following keyboard hook: https://svn.cyberduck.io/tags/release-4-1/source/ch/cyberduck/core/GlobalKeyboardHook.cs My problem is, what some keys from the device's hardware actually do is to sent a key combination (ex: left-alt + 1) to the application and a weird scenario is occurring: The application listens to normal keyboard inputs The simulator sends keys to other applications (ie: visual studio responds to the keys sent when debugging) The simulator can send single keys to the application (I can type) The simulator CANNOT send key combinations to the application (alt+1 is received as just 1 in the application) This started happenning when we imported the application's dll into the same process from the simulator. Could there be any reason why I can't simulate key combinations for a hook in the same process? Is there any easy fix for this?

    Read the article

  • Referencing a union inside a structure using union tag gives incorrect address

    - by AlanKley
    I had a need to declare a union inside a structure as defined below: struct MyStruct { int m_DataType; DWORD m_DataLen; union theData { char m_Buff [_MAX_PATH]; struct MyData m_myData; } m_Data; }; Initially, I tried accessing the union data as follows (before I added the m_Data declaration): MyStruct m_myStruct; char* pBuff = m_myStruct.theData::m_Buff; This compiles but returns to pBuff a pointer to the beginning of the MyStruct structure which caused me to overwrite the m_DataType & m_DataLength members when I thought I was writing to the m_Buff buffer. I am using Visual Studio 2008. Can anyone explain this unexpected behavior? Thanks.

    Read the article

  • F# on Mac: Syntax Error on Inner Function

    - by JBristow
    The following code: exception NoElements of string let nth(k, list) = let rec loop count list = match list with | head :: _ when count = k -> head | _ :: tail when count <> k -> loop (count+1) tail | [] -> raise (NoElements("No Elements")) loop 0 list ;; printfn "%A" (nth(2, [1, 1, 2, 3, 5, 8])) Produces the following errors when compiling on a mac, but not in Visual Studio 2010: nth.fs(10,0): error FS0191: syntax error. nth.fs(4,4): error FS0191: no matching 'in' found for this 'let'.

    Read the article

  • Convert 2 bytes to a number

    - by Vaccano
    I have a control that has a byte array in it. Every now and then there are two bytes that tell me some info about number of future items in the array. So as an example I could have: ... ... Item [4] = 7 Item [5] = 0 ... ... The value of this is clearly 7. But what about this? ... ... Item [4] = 0 Item [5] = 7 ... ... Any idea on what that equates to (as an normal int)? I went to binary and thought it may be 11100000000 which equals 1792. But I don't know if that is how it really works (ie does it use the whole 8 items for the byte). Is there any way to know this with out testing? Note: I am using C# 3.0 and visual studio 2008

    Read the article

  • asp.net mvc maproute

    - by niao
    Greetings, I have a problem with link in mvc application. When I run it via Visual Studio it's ok. The link then is as follows: http://localhost:2566/ActivateClient/Activate/6543e2d6-707d-44ae-94eb-a75d27ea0d07 when I run it via IIS7 the link is as follows: http://localhost/ActivationService/ActivateClient/Activate/6543e2d6-707d-44ae-94eb-a75d27ea0d07 The default route is as follows: public static void RegisterRoutes(RouteCollection routes) { routes.IgnoreRoute("{resource}.axd/{*pathInfo}"); routes.MapRoute( "Default", // Route name "{controller}/{action}/{id}", // URL with parameters new { controller = "Home", action = "Index", id = "" } // Parameter defaults ); } I assume I have to change this MapRoute, am I right? How to change it? ActivationService is my virtualDirectory in IIS. Can someone help me with this please?

    Read the article

  • How to Maintain per-Client State in a WCF Service?

    - by tbischel
    I've created a WCF service in which I would like it to maintain state between calls from the client. I figured the easiest way to do this was to add this attribute to the service: [ServiceBehavior(InstanceContextMode = InstanceContextMode.PerSession)] since this is supposed to keep a separate service alive for each client over the life of the client proxy (or timeout in the extreme case). I also added a test function that tracks a list of user inputs, and spits out a concatenated string with all the inputs over the life of the service. When I run this in the test client generated by visual studio, I find that the list I was using to hold past data is reset with each call. Is there something else I need to do to maintain state per session?

    Read the article

  • how to see my managed objects on the stack?

    - by smwikipedia
    I use SOS.dll in VisualStudio to debug my C# program. The program is as below. The debug command is !DumpStackObjects. class Program { static void Main() { Int32 result = f(1); } static Int32 f(Int32 i) { Int32 j = i + 1; return j; <===========BreakPoint is here } } After I input the "!dso" command in the immediate window of Visual Studio, the result is as below: OS Thread Id: 0xf6c (3948) ESP/REG Object Name Why there's nothing? I thought there should be the args i and local variable j. Thanks for my answering my naive questions...

    Read the article

  • Resulting .exe from PyInstaller with wxPython crashing

    - by Helgi Hrafn Gunnarsson
    I'm trying to compile a very simple wxPython script into an executable by using PyInstaller on Windows Vista. The Python script is nothing but a Hello World in wxPython. I'm trying to get that up and running as a Windows executable before I add any of the features that the program needs to have. But I'm already stuck. I've jumped through some loops in regards to MSVCR90.DLL, MSVCP90.DLL and MSVCPM90.DLL, which I ended up copying from my Visual Studio installation (C:\Program Files\Microsoft Visual Studio 9.0\VC\redist\x86\Microsoft.VC90.CRT). As according to the instructions for PyInstaller, I run: Command: Configure.py Output: I: computing EXE_dependencies I: Finding TCL/TK... I: could not find TCL/TK I: testing for Zlib... I: ... Zlib available I: Testing for ability to set icons, version resources... I: ... resource update available I: Testing for Unicode support... I: ... Unicode available I: testing for UPX... I: ...UPX available I: computing PYZ dependencies... So far, so good. I continue. Command: Makespec.py -F guitest.py Output: wrote C:\Code\PromoUSB\guitest.spec now run Build.py to build the executable Then there's the final command. Command: Build.py guitest.spec Output: checking Analysis building Analysis because out0.toc non existent running Analysis out0.toc Analyzing: C:\Python26\pyinstaller-1.3\support\_mountzlib.py Analyzing: C:\Python26\pyinstaller-1.3\support\useUnicode.py Analyzing: guitest.py Warnings written to C:\Code\PromoUSB\warnguitest.txt checking PYZ rebuilding out1.toc because out1.pyz is missing building PYZ out1.toc checking PKG rebuilding out3.toc because out3.pkg is missing building PKG out3.pkg checking ELFEXE rebuilding out2.toc because guitest.exe missing building ELFEXE out2.toc I get the resulting 'guitest.exe' file, but upon execution, it "simply crashes"... and there is no debug info. It's just one of those standard Windows Vista crashes. The script itself, guitest.py runs just fine by itself. It only crashes as an executable, and I'm completely lost. I don't even know what to look for, since nothing I've tried has returned any relevant results. Another file is generated as a result of the compilation process, called 'warnguitest.txt'. Here are its contents. W: no module named posix (conditional import by os) W: no module named optik.__all__ (top-level import by optparse) W: no module named readline (delayed, conditional import by cmd) W: no module named readline (delayed import by pdb) W: no module named pwd (delayed, conditional import by posixpath) W: no module named org (top-level import by pickle) W: no module named posix (delayed, conditional import by iu) W: no module named fcntl (conditional import by subprocess) W: no module named org (top-level import by copy) W: no module named _emx_link (conditional import by os) W: no module named optik.__version__ (top-level import by optparse) W: no module named fcntl (top-level import by tempfile) W: __all__ is built strangely at line 0 - collections (C:\Python26\lib\collections.pyc) W: delayed exec statement detected at line 0 - collections (C:\Python26\lib\collections.pyc) W: delayed conditional __import__ hack detected at line 0 - doctest (C:\Python26\lib\doctest.pyc) W: delayed exec statement detected at line 0 - doctest (C:\Python26\lib\doctest.pyc) W: delayed conditional __import__ hack detected at line 0 - doctest (C:\Python26\lib\doctest.pyc) W: delayed __import__ hack detected at line 0 - encodings (C:\Python26\lib\encodings\__init__.pyc) W: __all__ is built strangely at line 0 - optparse (C:\Python26\pyinstaller-1.3\optparse.pyc) W: __all__ is built strangely at line 0 - dis (C:\Python26\lib\dis.pyc) W: delayed eval hack detected at line 0 - os (C:\Python26\lib\os.pyc) W: __all__ is built strangely at line 0 - __future__ (C:\Python26\lib\__future__.pyc) W: delayed conditional __import__ hack detected at line 0 - unittest (C:\Python26\lib\unittest.pyc) W: delayed conditional __import__ hack detected at line 0 - unittest (C:\Python26\lib\unittest.pyc) W: __all__ is built strangely at line 0 - tokenize (C:\Python26\lib\tokenize.pyc) W: __all__ is built strangely at line 0 - wx (C:\Python26\lib\site-packages\wx-2.8-msw-unicode\wx\__init__.pyc) W: __all__ is built strangely at line 0 - wx (C:\Python26\lib\site-packages\wx-2.8-msw-unicode\wx\__init__.pyc) W: delayed exec statement detected at line 0 - bdb (C:\Python26\lib\bdb.pyc) W: delayed eval hack detected at line 0 - bdb (C:\Python26\lib\bdb.pyc) W: delayed eval hack detected at line 0 - bdb (C:\Python26\lib\bdb.pyc) W: delayed __import__ hack detected at line 0 - pickle (C:\Python26\lib\pickle.pyc) W: delayed __import__ hack detected at line 0 - pickle (C:\Python26\lib\pickle.pyc) W: delayed conditional exec statement detected at line 0 - iu (C:\Python26\pyinstaller-1.3\iu.pyc) W: delayed conditional exec statement detected at line 0 - iu (C:\Python26\pyinstaller-1.3\iu.pyc) W: delayed eval hack detected at line 0 - gettext (C:\Python26\lib\gettext.pyc) W: delayed __import__ hack detected at line 0 - optik.option_parser (C:\Python26\pyinstaller-1.3\optik\option_parser.pyc) W: delayed conditional eval hack detected at line 0 - warnings (C:\Python26\lib\warnings.pyc) W: delayed conditional __import__ hack detected at line 0 - warnings (C:\Python26\lib\warnings.pyc) W: __all__ is built strangely at line 0 - optik (C:\Python26\pyinstaller-1.3\optik\__init__.pyc) W: delayed exec statement detected at line 0 - pdb (C:\Python26\lib\pdb.pyc) W: delayed conditional eval hack detected at line 0 - pdb (C:\Python26\lib\pdb.pyc) W: delayed eval hack detected at line 0 - pdb (C:\Python26\lib\pdb.pyc) W: delayed conditional eval hack detected at line 0 - pdb (C:\Python26\lib\pdb.pyc) W: delayed eval hack detected at line 0 - pdb (C:\Python26\lib\pdb.pyc) I don't know what the heck to make of any of that. Again, my searches have been fruitless.

    Read the article

  • Runing directx samples on a Windows Mobile 6.1 device

    - by Sil
    Hi, I tried to run the directx samples from ..\Windows Mobile 6 SDK\Samples\PocketPC\CPP\win32\directx\d3dm\tutorials on m Samsung Omnia and on the emulator and it doesn't work because a deployment error. I am using Microsoft Visual Studio 2008 and have installed Windows Mobile SDK Standard and Professional refresh. The device is correctly plugged in and set up for active sync(I know this because other samples work, also a creating Win32 smart device and running it works) When I try to run the application it compiles without errors but the message: " There were deployment errors, Continue? Yes/No" appears If I manually copy the application from the debug folder to the device and run it from there, it works. The same deployment error message appears if I try it on an emulator. Other applications are deploying successfully. Is there any way to make the deployment work? Maybe there is an obscure option I need to set... Thank you

    Read the article

  • XML deserialization doesn't read in second level

    - by Andy
    Sorry if the title doesn't make much sense, but I'm not too familiar with the terminology. My question is: I have a config.xml file for a program I'm working on. I created an xsd file by 'xsd.exe config.xml'. I then took this xsd and added it to the solution in visual studio. My last step used a program called xsd2code that turned that xsd file into a class I can serialize too. The problem is it doesn't read more then a layer deep in the xml tree. By this I mean the elements in the root node get deserialized into my object, but those that are in a node inside the root node are not. I found this out by putting a breakpoint after the deserialization and looking at my object. Any Ideas? Let me know if this needs some clarification or you need a snippet of something.

    Read the article

  • Why don't the .net 4.0 charting controls work in Visual Web Developer 2010 Express?

    - by kc
    The .net charting controls are now built into .net 4.0. They work great in Visual Studio 2010. However, they do not work in Visual Web Developer 2010 Express (which is what I have at home.) I get the error, System.Web.HttpException: Error executing child request for ChartImg.axd. That sounds like the message from .net 3.5 if charting wasn't set up correctly. But the bottom of the same page says, "Version Information: Microsoft .NET Framework Version:4.0.30319; ASP.NET Version:4.0.30319.1" Does anyone know why this doesn't work?

    Read the article

  • trying to decide between asp.net and jsp

    - by Amir
    Hey Guys, I am wondering if anyone can shed some lights on the situation. I am about to start a project and trying to figure out what solution is best to go with asp.net or java jsp pages I have personally worked alot with .net and am really happy with the framework and Visual studio as IDE I find it easy to work with and there is a massive community support behind .net, i can get alot done quickly I have not every written anything use java jsp, there will be a learning curve here , so my experience is limited here. however after seeing jira i am very impressed with its capabilities, it has changed alot since the old days ( java 1.2 ) that i used to work with, and the fact that it runs under linux is a huge plus, so i am trying to decide is the learning curve, worth the price ? so given the situation above what would you recommended? Thanks, Amir

    Read the article

  • Referencing code in VB.NET

    - by akramnik
    I'm not at all familiar with VB.NET or ASP. I need to create a simple page which makes a call to a remote web service. I used the wsdl utility which comes with the DotNet SDK to generate a service proxy and write it to a VB file. Unfortunately I have no idea how to reference this code in either my ASPX file or the code behind VB file so I can create an instance of the proxy. Edit: I should have qualified this by noting that I'm not using visual studio. I just coded up a .aspx with a .vb behind it and dropped it into an IIS location. Is there a way to do what you're suggesting outside of VS?

    Read the article

  • sql database connection on remote server

    - by arti pathak
    i create my web site on asp.net and i create database in sql using inbuilt it in visual studio i use step to create database 1.right click on solution explorer then add newSqldatabase then ok then if i connect it by coding then it will work on my local PC but actuall i am making website so i want to store it on my web server then if i load databse file (.mdf) file in my web server where my all files are loaded then it is showing it error "A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified)" so please help me and send me all step how i create database and what coding i use to connect on remote server....... Thank You......

    Read the article

  • Benchmark for a .NET WinPcap wrapper

    - by brickner
    I'm developing a .NET wrapper for WinPcap called Pcap.Net. I'm trying to make sure this wrapper has high performance and I want to compare it to WinPcap and to other .net wrappers for WinPcap. The features I want to profile are: WinPcap native features (sending packets in different ways, receiving packets in different ways...) Interpreting packets that Pcap.Net knows how to interpret (like Etherent, IPv4, UDP, TCP, ICMP, ...) Building packet that Pcap.Net knows how to build (the same types it knows how to interpret). I also want to be able to profile the benchmark using Visual Studio 2010 Ultimate profiling tools. My question is: What should my benchmark exactly do to cover these issues and how would you suggest to build it?

    Read the article

  • Distribute pre-compiled python extension module with distutils

    - by Toji
    Quick one today: I'm learning the in's and out's of Pythons distutils library, and I would like to include a python extension module (.pyd) with my package. I know of course that the recommended way is to have distutils compile the extension at the time the package is created, but this is a fairly complex extension spanning many source files and referencing several external libs so it's going to take some significant playing to get everything working right. In the meantime I have a known working build of the extension coming out of Visual Studio, and would like to use it in the installer as a temporary solution to allow me to focus on other issues. I can't specify it as a module, however, since those apparently must have an explicit .py extension. How could I indicate in my setup.py that I want to include a pre-compiled extension module? (Python 3.1, if it matters)

    Read the article

  • Why does Silverlight 4 Tools only give partial intellisense?

    - by Edward Tanguay
    I finally got Silverlight 4 Toolkit installed , referenced and working after the difficulty of finding the right namespace described in this question. But intellisense doesn't work fully: after I type "tk:", it doesn't pop up the various controls I have available, but if I type a control name out, e.g. DockPanel, then it works, as shown below. It will even give me intellisense after I type tk:DropPanel, which is odd. How can I get intellisense to work in all cases for the Silverlight 4 Toolkit? I can imagine I need another namespace, but this site says that this reference: is now all you need (and will be automatically used by both Visual Studio and Blend)

    Read the article

  • What advantages does TFS 2010 have over Axosoft OnTime?

    - by Russell
    I am currently creating a business case for rolling out TFS 2010 as our source control and bug/release management tool. We currently use OnTime for our bug tracking software and subversion for our SCM. I was wondering what advantages TFS 2010 has over OnTime? I have done some thinking so far and would love to hear responses: TFS 2010 allows linking changesets-work items-builds TFS 2010 provides greater customisation of workflow than OnTime TFS 2010 is integrated into the Visual Studio IDE - This requires less apps to be open and less window flicking Thanks in advance.

    Read the article

  • MFC SDI Application without a default "New Document" on Startup

    - by Jd
    My application is an SDI with multiple views. By default, it creates a new document when the application starts. I want to modify this behavior so that a new document is created only when user explicitly clicks on "New". Or at least mimic this behavior. Any ideas? I am using Visual Studio 2008 with MFC feature pack. I googled and found some solution to this problem in an old MS Journal article. But unfortunately it doesn't seem to work now. Any workarounds or solutions? In short, I need to differentiate between framework call to OnFileNew() and User Click on New.

    Read the article

  • SQL 2008 Database tuning advisor won't start

    - by Andrew Hancox
    For some reason I can't get DTA to connect to my development machine. It connects to a remote DB just fine but when I point it to my dev machine I get an error saying: Failed to initialize MSDB database for tuning (exit code: -1073741819). I'm pretty sure it's not a permissions issue since I've used profiler to capture what it's doing and all of the commands it's run so far look fine and are being run under my account which is associated with the sysadmin role, when I run them in sql management studio they go through fine. I'm pretty convinced that the problem is related to creating the objects in MSDB that are used by DTA but I tried creating these manually (I found scripts on the web) and it just seems to push the problem along the line slightly. I'm going out of my mind - have even tried reinstalling SQL but that's not fixed it. I'm using SQL 2008 with SP1 (10.0.2531) on windows server 2008 (patched up to date). SAVE ME!!!!!

    Read the article

< Previous Page | 432 433 434 435 436 437 438 439 440 441 442 443  | Next Page >